Вы находитесь на странице: 1из 13

1'-0"

10'-8"

2"
8'-111

AC UNITS - OUTDOOR MACHINES

CHANGE
ROOM

DIAS

CHANGE
ROOM

CAFETERIA - 50 SEATS

PANTRY

BG-7 BG-6 BG-5 BG-4 BG-1 BG-7 BG-6 BG-5 BG-4 BG-3 BG-2 BG-1

BG-2 BG-2 BG-2

AG-7 AG-7

DN DN

AG-6
41'-01
2"
AG-6

AG-5 AG-5

AG-4 AG-4
2"
26'-31

40'-4"
39'-6"

AG-3 AG-3

9'-0"
4'-0"

2"

11'-2"
10'-21

AG-2 AG-2

2'-2"
17'-8" 28'-2"
17'-7"

AG-1 AG-1

OPTION - 2
AUDITORIUM AND CAFETERIA AUDITORIUM AND CAFETERIA
TERRACE - PROPOSED FLOOR PLAN TERRACE - FLOORING PLAN
LIST OF CONTENTS

S.No DWG. NAME SHEET NO.

01 GENERAL NOTES SN-TR-001

02 EXISTING TERRACE PLAN SN-TR-002

03 CONTEXT PLAN SN-TR-003

04 PROPOSED TERRACE PLAN SN-TR-004

05 SECTIONS SN-TR-005

06 ELEVATIONS SN-TR-006

07 REFLECTED CEILING PLAN TO BE ISSUED

08 FLOORING PATTERN SN-TR-008

09 WALL ELEVATIONS TO BE ISSUED

10 DETAILS TO BE ISSUED

11 DOORS & WINDOW SCHEDULE TO BE ISSUED

PROPOSED TERRACE FLOOR FOR SANDOOR MEDICALS PVT.LTD. DRAFT COPY FOR REVIEW ONLY
NOT FOR CONSTRUCTION
BANJARA HILLS - HYDERABAD
CO ORDINATE WITH M.E.P DWGS
DATE:-20-12-2016
NOTES
GENERAL NOTES :
1. PRESENTED DRAWING INDICATE THE GENERAL SCOPE
OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN
CONCEPT,THE DIMENSIONS OF THE BUILDING,THE MAJOR ARCHITECTURAL ELEMENTS AND THE TYPE OF
STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS.
THE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE
AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. ON THE BASIS OF THE THE GENERAL SCOPE
INDICATED OR DESCRIBED, THE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK.

2. THE CONTRACTOR SHALL CHECK AND VERIFY ALL THE DIMENSIONS AND JOB CONDITIONS BEFORE THE JOB COMMENCEMENT OF WORK AND BE RESPONSIBLE
FOR THEIR ACCURACY.ANY DISCREPANCIES BETWEEN FIELD CONDITIONS OR WITHIN THE DOCUMENTS ARE TO BE REPORTED TO THE ARCHITECT VIA THE
CONSTRUCTION MANAGER.

3. THE CONTRACTOR SHALL PREPARE "COORDINATION DRAWINGS" WHICH REPRESENT THAT ALL TRADES INVOLVED IN THE PROJECT HAVE COORDINATED THE
INSTALLATION OF THEIR WORK SO AS TO AVOID CONFLICTS AND/OR MISALIGNMENTS.

4. THE CONTRACTOR SHALL PERFORM ALL THE WORK IN ACCORDANCE WITH ALL APPLICABLE CODES,ORDINANCES,SAFETY ORDERS AND REGULATIONS AND
OWNER POLICIES AND DIRECTIVES.

5. THE CONTRACTOR SHALL COORDINATE, NOTIFY AND SCHEDULE ALL REMOVALS WITH THE OWNER'S REPRESENTATIVE PRIOR TO TO PROCEEDING THE WORK.

6. UNDER COMPLETION REMOVE ALL TEMPORARY PIPING AND EQUIPMENT, SHORING, SCAFFOLDS ETC. AND LEAVE ALL AREAS CLEAN AND FREE FROM MATERIAL
DEBRIS RESULTING FROM WORK PERFORMED.

7. ATTENTION IS DIRECTED TO THE FACT, THAT DUE TO THE NATURE OF THE PROJECT AND PREVIOUSLY EXECUTED CONTRACTORS, THE EXACT EXTENT OF WORK
CANNOT BE ALWAYS BE ACCURATELY DETERMINED PRIOR TO THE COMMENCEMENT OF WORK. ACTUAL FIELD CONDITIONS MAY REQUIRE MODIFICATIONS T
O CONSTRUCTION DETAILS AND WORK QUANTITIES. THE CONTRACTOR SHALL NOTIFY THE CM BEFORE ADAPTING THE WORK IN ACCORDANCE WITH FIELD
CONDITIONS.

8. ALL WORK CONTAINED IN ALL CEILINGS SHALL BE SIMULTANEOUSLY REPRESENTED ON A SINGLE DRAWING PREPARED BY CONTRACTORS, TO CONFIRM THAT
ALL TRADES "FIT" WITHIN THE ALLOTTED SPACE. ALL CONFLICTS SHALL BE RESOLVED PRIOR TO THE SUBMITTING SHOP DRAWINGS FOR THE CONSTRUCTION
MANAGER REVIEWS AND PRIOR TO THE EXECUTING ANY OF THE WORK WITHIN THE CEILING CAVITY.
DRAFT COPY FOR REVIEW
9. ALL CEILING DEVICES INCLUDING LIGHT FIXTURES, SPEAKERS, EXIT SIGNS ,DIFFUSERS, GRILLES, SPRINKLERS AND SMOKE DETECTORS ARE TO BE CENTERED ARCHITECT
IN TILE UNLESS NOTED OTHERWISE (U.N.O). ALL DEVICES SHOWN ARE FOR LOCATION INFORMATION ONLY. REFER TO MECHANICAL, ELECTRICAL , PLUMBING
AND FIRE PROTECTION (M.E.P.F) DRAWINGS FOR QUANTITIES AND INSTALLATION.

10. EXISTING WORK IS TO BE PROTECTED DURING CONSTRUCTION AND KEPT FREE OF DEBRIS. ANY EXISTING WORK DAMAGED DURING CONSTRUCTION IS TO B E
REPLACED WITH WORK OF EQUAL QUALITY TO THE CM.
DRAWN: CHECKED BY: DATE:
11. USE DIELECTRIC SEPARATOR ON ALL DISSIMILAR METALS.
V.ABHISHEK SK 20-12-2016

SCALE: DRAWING NO: REV. NO:


12. COORDINATE LOCATION OF OUTLET BOX FACES WITH SCHEDULED APPLIED FINISH THICKNESS. 1:00 SN-TR-001 00

CLIENT:
13. FOR WALL/MATERIAL , CEILING MATERIAL LEGEND AND FLOOR MATERIAL LEGEND AND KEY NOTES OF THE RESPECTIVE ELEMENT REFER TO DRAWING NO.
SN-TR-010 SANDOOR MEDICALS PVT. LTD.
DWG. TITLE:

GENERAL NOTES

PROJECT NAME:

PROPOSED CANTEEN FOR SANDOOR


AT BANJARA HILLS
NOTES

A B C D E F G

1
EXISTING AIR CONDITIONING
INFRASTRUCTURE

DN

FOR DETAIL FLOOR PLAN SEE


SHEET # SN-TR-004

5
PROPOSED AUDITORIUM
AND
CAFETERIA

6
DRAFT COPY FOR REVIEW
ARCHITECT

DRAWN: CHECKED BY: DATE:

7 V.ABHISHEK SK 20-12-2016

SCALE: DRAWING NO: REV. NO:


1:16 SN-TR-003 00

CLIENT:

SANDOOR MEDICALS PVT. LTD.


DWG. TITLE:

CONTEXT PLAN

A CONTEXT PLAN PROJECT NAME:


TR-003
PROPOSED CANTEEN FOR SANDOOR
AT BANJARA HILLS
NOTES

A B C D E F G

EXISTING AIR CONDITIONING


DN INFRASTRUCTURE

EXISTING STEEL BEAMS


ENGINEER & CONTRACTOR TO
EXISTING COLUMNS VERIFY STRUCTURE ON SITE
TYPICAL

6
DRAFT COPY FOR REVIEW
EXISTING COLUMNS ARCHITECT
TYPICAL

DRAWN: CHECKED BY: DATE:


V.ABHISHEK SK 20-12-2016

SCALE: DRAWING NO: REV. NO:


7 1:16 SN-TR-002 00

CLIENT:

SANDOOR MEDICALS PVT. LTD.


DWG. TITLE:

EXISTING TERRACE FLOOR PLAN

A EXISTING TERRACE FLOOR PLAN PROJECT NAME:


TR-002
PROPOSED CANTEEN FOR SANDOOR
AT BANJARA HILLS
1"
41'-02 NOTE:
E W1 F Z G

D1
WD1

3 WALL SCHEDULES:
W1- PRECAST HIGH WEIGHT AEROCON WALL
PANELS
W2- CUTTEN WALL

01
LVL +2'-6" LVL +3'-6"
04 02
LEVEL TO BE X 03 DOOR SCHEDULES:
DETERMIND XXX D1- 4'-0" SOLID METAL DOUBLE DOOR
AT SITE
AUDITORIUM D2- 3'-6" SINGLE LEAF METAL DOOR
W2 D3- 3'-0" FLUSH DOOR
X
X
VERANDH

UP
EXISTING STRUCTURE
(SCREEN) WINDOW SCHEDULES:
5 WD1- 2'-0" WINDOW
WD1 WD2- 4'-0" WINDOW

D1

W1 OVER HEAD KITCHEN


STORAGE

W2
W1
WD2

6
PANTRY
CAFETERIA
LVL +2'-6" KITCHEN COUNTER
D2 D3 DRAFT COPY FOR REVIEW
ARCHITECT
WD1
05
08 06 X
07 XXX

HAND WASH
Y DRAW: CHECKED BY: DATE:
Y V.ABHISHEK SK 20-12-2016

SCALE: DRAWING NO: REV. NO:


1:8 SN-TR-004 00
EXISTING BUILDING
CLIENT:
W1
SANDOOR MEDICALS PVT. LTD.
DWG. TITLE:
WD1
PROPOSED FLOOR PLAN
7
WD2 PROJECT NAME:

A PROPOSED FLOOR PLAN Z


TR-004
NOTES

TRUSS STEEL JOIST TO BE CORRUGATED METAL


DESIGNED BY STRUCTURAL ROOF DECKING
ENGINEER

AEROCON PANEL FLOOR ON 4" WALL


LIGHT WEIGHT STEEL STRUCTURE
DESIGNED BY STRUCTURAL ENGINEER

TO BE DETERMIND AT SITE GROUND LINE/BASELINE

DRAFT COPY FOR REVIEW


A SECTION AT ZZ
TR-005 ARCHITECT

DRAW: CHECKED BY: DATE:


V.ABHISHEK SK 20-12-2016

SCALE: DRAWING NO: REV. NO:


1:8 SN-TR-005 00

CLIENT:

DWG. TITLE:

SECTION

PROJECT NAME:
NOTES

X FASIA PANEL
XXX TRUSS STEEL JOIST TO BE CORRUGATED METAL
HIGH PRESSURE LAMINATE
DESIGNED BY STRUCTURAL ROOF DECKING
ENGINEER X
XXX

1'-0"

10'-8"

8'-112"
4" WALL

1
AEROCON PANEL FLOOR ON
LIGHT WEIGHT STEEL STRUCTURE
DESIGNED BY STRUCTURAL ENGINEER

TO BE DETERMIND AT SITE GROUND LINE/BASELINE

A SECTION AT XX
TR-005

X SIM
FASIA PANEL TRUSS STEEL JOIST TO BE CORRUGATED METAL
XXX HIGH PRESSURE LAMINATE DESIGNED BY STRUCTURAL ROOF DECKING
ENGINEER SIM X
XXX DRAFT COPY FOR REVIEW
ARCHITECT

AEROCON PANEL FLOOR ON


LIGHT WEIGHT STEEL STRUCTURE DRAW: CHECKED BY: DATE:
DESIGNED BY STRUCTURAL ENGINEER V.ABHISHEK SK 20-12-2016

SCALE: DRAWING NO: REV. NO:


1:8 SN-TR-005 00

CLIENT:
TO BE DETERMIND AT SITE GROUND LINE/BASELINE

DWG. TITLE:

SECTION
B SECTION AT YY
TR-005
PROJECT NAME:
ARCHITECT

SHIVA MOHAN KOVARULU


COA # CA/2012/ 52724
DRAW: CHECKED BY:

SCALE: DRAWING NO:

CLIENT:

DWG. TITLE:

PROPOSED REFLECTED CEILING PLAN

PROPOSED REFLECTED CEILING PLAN PROJECT NAME:


NOTES
E F G
2

UP
2-STEPS
WOOD FINISH
VITRIFIED TILES
3

LVL +2'-6" F1/CARPET LVL +3'-6"

26'-32"
1
40'-4"
AUDITORIUM
VERANDH
39'-6"

UP

UP
2-STEPS

9'-0" EXISTING STRUCTURE

4'-0"

10'-22"
11'-2"
PANTRY (SCREEN)

1
F2/VINYL

6
DRAFT COPY FOR REVIEW
F4/VITRIFIEDTILES
ARCHITECT
F3/VINYL

2'-2"

28'-2"
CAFETERIA
LVL +2'-6"
DRAW: CHECKED BY: DATE:

HAND WASH
V.ABHISHEK SK 20-12-2016

17'-7"
17'-8"
SCALE: DRAWING NO: REV. NO:
F4/VITRIFIEDTILES
1:8 SN-TR-008 00

CLIENT:

DWG. TITLE:

PROPOSED FLOORING PATTERN


A PROPOSED FLOORING PATTERN 4" LEDGE
PROJECT NAME:
TR-008

7
NOTES

TO BE ISSUED TO BE ISSUED TO BE ISSUED TO BE ISSUED

DRAFT COPY FOR REVIEW


ARCHITECT

DRAW: CHECKED BY: DATE:


V.ABHISHEK SK 20-12-2016
SCALE: DRAWING NO: REV. NO:
1:8 SN-TR-006 00
CLIENT:
A ELEVATION
TR-006

DWG. TITLE:

ELEVATIONS

PROJECT NAME:
1'-0"

10'-8"

8'-112"
1
AC UNITS - OUTDOOR MACHINES

4'-6" AISLE CHANGE


ROOM

DIAS
VESTIBULE / AUDITORIUM - 100 SEATS
CORRIDOR

STEEL CHANGE
STRUCTURE
UNDERNEATH 4'-6" AISLE ROOM

CAFETERIA - 50 SEATS

PANTRY

BG-7 BG-6 BG-5 BG-4 BG-1 BG-7 BG-6 BG-5 BG-4 BG-3 BG-2 BG-1

BG-2 BG-2 BG-2

AG-7 AG-7

DN DN DN DN

AG-6 41'-01
2"
AG-6

AG-5 AG-5

AG-4 AG-4

2"
26'-31
40'-4"

39'-6"
AG-3 AG-3

9'-0"

4'-0"

2"
11'-2"

10'-21
AG-2 AG-2

2'-2"

28'-2"
17'-7"
17'-8"
AG-1 AG-1

OPTION - 2
AUDITORIUM AND CAFETERIA AUDITORIUM AND CAFETERIA AUDITORIUM AND CAFETERIA
TERRACE - EXISTING FLOOR PLAN TERRACE - PROPOSED FLOOR PLAN TERRACE - FLOORING PLAN
1'-0"

10'-8"

8'-112"
1
AC UNITS - OUTDOOR MACHINES

4'-6" AISLE CHANGE


ROOM

DIAS
VESTIBULE / AUDITORIUM - 100 SEATS
CORRIDOR

STEEL CHANGE
STRUCTURE
UNDERNEATH 4'-6" AISLE ROOM

CAFETERIA - 50 SEATS

PANTRY

BG-7 BG-6 BG-5 BG-4 BG-1 BG-7 BG-6 BG-5 BG-4 BG-3 BG-2 BG-1

BG-2 BG-2 BG-2

AG-7 AG-7

DN DN DN DN

AG-6 41'-01
2"
AG-6

AG-5 AG-5

AG-4 AG-4

2"
26'-31
40'-4"

39'-6"
AG-3 AG-3

9'-0"

4'-0"

2"
11'-2"

10'-21
AG-2 AG-2

2'-2"

28'-2"
17'-7"
17'-8"
AG-1 AG-1

OPTION - 2
AUDITORIUM AND CAFETERIA AUDITORIUM AND CAFETERIA AUDITORIUM AND CAFETERIA
TERRACE - EXISTING FLOOR PLAN TERRACE - PROPOSED FLOOR PLAN TERRACE - FLOORING PLAN