TIA 568.

0-D Generic Telecommunications Cabling for Customer Premiss

TIA 568.1-D Commercial Building Telecomunications Standard

Cat 5e 100 MHz

TIA 568 TIA 568-C2 Balanced Twited-pair Telecommunications Cabling and Components Standard Cat 6 250 MHz

Cat 6A 500 MHz

TIA 568.3-D Optical Fiber Cabling and Components Standard

TIA 568-C4 Broadband Coaxial Cabling and Components Standard

TIA 569 Telecommunications Pathway and Spaces

TIA 570 Residential Telecommunications Infraestructure Standard

TIA 606 Administration Standard for Telecommunications Infraestructure

TIA 607 Aterramento para sistemas de Telecom

TIA 942 Cabeamento Estruturado para Datacenters

TIA 1005 Cabeamento Estruturado para Industrias

TIA 1179 Hospital Structure Cabling

TIA 455-1 Cable Flexing for ber Optic interconnecting devices

TIA 455-2 Impact test measurements for ber optic devices

TIA 455-4 Temperatura

TIA 455-5 Humidity

TIA 455-6 Cable Retention

TIA 455-8 Measurement of splice or connector loss and reectance using an OTDR

TIA 455-13

TIA 455 TIA 455-21 Durability 500 times

TIA - Telecommunication Industries Association TIA 455-34 Method A - factoring Test

TIA 455-78 Field Test

MM Return loss >=20dB


TIA 455-107 Return Loss
Return Loss >=35dB
SM
Return Loss >=55dB (Analog video)

TIA 455-171 Multimode attenuation

TIA 455-188 Low Temperature -10C

TIA 492AAAA OM1 62,5 micrometro core

TIA 492AAAB OM2 50 micrometro core

TIA 492AAAC OM3 50 micrometro core

TIA 492 TIA 492AAAD OM4 50 micrometro core

TIA 492AAAE OM5 50 micrometro core

TIA 492CAAA OS1 9 micrometro core

TIA 492CAAB OS2 9 micrometro core

TIA 526-7 Measurement of optical power loss of installed Multimode


TIA 526
TIA 526-14B Measurement of optical power loss of installed Singlemode

TIA 598 Optical ber Cable color coding


EUA TIA 604-3 Conector SC
TIA 604
TIA 604-5 Conector MPO

TIA 4966 Educational

Institute Eletrical Eletronic Engineer

802.1 Higher Layer LAN Protocols Working Group

802.3.ab 1000baseT

802.3an 10GbaseT

802.3bq 25G/40GbaseT
IEEE
802.2 Ethernet Working Group 2.5 GbaseT CAT 5e
802.3bz 2.5/5GbaseT
5.0 GbaseT CAT 6

802.3af POE 15.4 W

802.3at POE 30 W

802.11 Wireless LAN Working Group

NFPA NEC - National Eletric Code (NFPA 70-2014)

IETF Internet Engineering Task Force

S-121-744 Optical ber Outside plant microduct cables


ICEA Insulated Cable Engineers Association
S-104-696 Indoor-outdoor optical ber cable

ISO 11801
ISO
ISO 61300-3-35 Polish Face

IEC 61754-4 Subscribe Conector

IEC 61754-15 E2000 Conector

IEC 61754-20 LC - Lucent Conector


IEC
IEC 61280-4-1 Insertion loss testing of multimode ber optic cabling

IEC 61280-4-2 Insertion and return loss testing of singlemode ber optic cabling
Standard Tree IEC 61280-4-4 PMD testing of installed ber optic cabling

G.651 MultiMode Fiber


INTERN. attributes, contains the recommended attributes and values needed to support applications such as
those recommended in [ITU-T G.957] and [ITU-T G.691] up to STM-16, as well as 10 Gbit/s up to 40 km
G.652A (Ethernet) and STM-256 for [ITU-T G.693].

attributes, contains recommended attributes and values needed to support higher bit rate
applications, up to STM-64, such as some in [ITU-T G.691] and [ITU-T G.692], STM-256 for some
applications in [ITU-T G.693] and [ITU-T G.959.1]. Depending on the application, chromatic dispersion
G.652B accommodation may be necessary.
G.652 SingleMode Fiber - Standard
attributes, is similar to ITU-T G.652.A, but allows transmissions in portions of an extended wavelength
G.652C range from 1360 nm to 1530 nm.

attributes, is similar to ITU-T G.652.B, but allows transmissions in portions of an extended wavelength
ITU-T G.652D range from 1360 nm to 1530 nm.

G.653 Characteristics of a dispersion-shifted, single-mode optical bre and cable

G.654 Characteristics of a cut-o shifted single-mode optical bre and cable

G.655 Characteristics of a non-zero dispersion-shifted single-mode optical bre and cable

G.656 Characteristics of a bre and cable with non-zero dispersion for wideband optical transport

G.657.A1 bres are primarily intended for use in OSP and have been enthusiastically adopted by network owners

G.657 G.657.A2 G.657.A2 and G.657.B3 compliant bres are more commonly used inside the building.

G.657.B3 G.657.A2 and G.657.B3 compliant bres are more commonly used inside the building.

G.694-1 Spectral grids for WDM applications: DWDM frequency grid

NBR 14565:2013 Cabeamento Estruturado e Datacenter

NBR 9050:2015 Acessibilidade

NBR 5410 Baixa Tenso

NBR 5419 SPDA

NBR 16264 Cabeamento Estruturado Residencial


ABNT Aspectos abordados:
BRASIL
- Espaos para cabeamento estruturado
- Caminhos para cabeamento estruturado
- Planejamento da instalao
- Infraestrutura comum em edifcios multiusurios
- Ocupao de eletrodutos e eletrocalhas
- Dimensionamento de prumadas
NBR 16415:2015 Caminhos e espaos para cabeamento estruturado - Sistema corta-fogo