Вы находитесь на странице: 1из 8

Webtec Products Limited

Variable priority flow dividers


2FV2V and related models
Ideal for controlling hydraulic motor
and cylinder speeds
VFD50

FDM

CK2FV2V

FVDVRV

2FV2V

Quality Hydraulic Components


from the Webtec Range
Quality Hydraulic Components from the Webtec Range

2FV2V Series

Variable Priority
Flow Dividers

PRIORITY TYPE FLOW DIVIDERS split a single input Features


flow into a Priority (regulated) flow and a By-pass
(excess) flow which can be returned directly to the oil Clearly marked single-turn hand dial permits
reservoir or used to power a second system. In many fast visual adjustments to pre-determined
instances this dispenses with the need for another Priority flow and fast easy adjustments of
pump to operate a second system. Priority circuit to meet varying requirements.

Specifications Pressure compensated permitting both


Priority and By-pass to be used
Maximum Pressure: simultaneously at varying pressures without
250 bar (working) affecting the Priority flow rate.

Total flow capacity: Can be used as unidirectional two port in line


114 lpm flow control by plugging the By-pass flow
port. (NB: in this configuration a relief valve
Regulated flow capacity: must be used on the inlet line).
see Table 2, ordering codes
All models (except manifold mount) can be
Porting: supplied with an adjustable pressure relief
see Table 3, ordering codes valve or check valve on Priority flow. Anti-
cavitation check valve can be routed between
Material: the By-pass and Priority flows.
Steel components in cast iron body; aluminium knob (steel
knob optional)

Weight:
2.10 to 3.50Kg

Mounting:
two bolt

Relief valve (optional):


Adjustable between 35 207 bar
Max. Priority flow - 50 lpm

Check valve (optional):


250 bar working pressure
(Anti-cavitation check valve available)

Symbol
See Installation Detail

1
Quality Hydraulic Components from the Webtec Range
ORDERING CODES Typical Code M 2FV2V 125 J ( )

Manifold mounting available on 2FV2V model only

Valve Type (Table 1)

Regulated Flow Capacity (Table 2)

Porting (Table 3)

Pressure Setting (bar, if Relief Valve required)

Table 1: Valve Type Table 2: Regulated Flow

Code Description Code Regulated Flow


030 0 - 11 lpm
2FV2V No Relief Valve
050 0 - 19 lpm
RV2FV2V Relief Valve between Priority
and Excess Flow Port 080 0 - 30 lpm
RVXD2FV2V Externally Drained Relief Valve 125 0 - 47 lpm
CK2FV2V Check Valve between Priority and Inlet Flow Port 200 0 - 76 lpm

AC2FV2V Anti-cavitation Check Valve between By-pass 250 0 - 95 lpm


and Priority Flow Port 300 0 - 114 lpm

Table 3: Porting*

Code Port Threads Inlet Regulated Relief Valve External Drain


Flow and Excess Flow where fitted

J 3/ BSP 1/ BSP
4 4

A 3/ NPT 1/ NPT
4 4

M M22 x 1.5 M14 x 1.5

G 1.1/16 - 12 SAE 9/ - 20 SAE


16

H 1/ BSP 1/ BSP
2 4

T 3/ BSP 1/ BSP
8 4

* Other threads available to special order.

TYPICAL PRESSURE DROP 2FV2V SERIES TYPICAL PRESSURE DROP CK2FV2V SERIES
(in forward direction) (in reverse direction)
12 50

10 40
Pressure Drop (bar)

Pressure Drop (bar)

8 30

6 20

4 10

2 0
0 20 40 60 80 100 120 0 20 40 60 80 100
Input Flow (lpm) Reverse Flow (lpm)

Curve established using hydraulic mineral oil ISO 32 with viscosity of 21 centistokes at 50C

2
Quality Hydraulic Components from the Webtec Range
INSTALLATION DETAILS
Dimensions in millimetres
2FV2V (No Relief Valve)
77.8
By-Pass Flow Port Inlet

67.8 SYMBOL
12 0

PR
4
10

35.3 27.4
P

6
8
Inlet

145.7
46

REG
By-pass Priority
Regulated
Flow

25.9
96.8 Regulated Port
49.5
2 Mtg Holes
7.1 Thru

RV2FV2V (Internal Relief Valve between Priority and Excess Flow Ports)

Minimum Adjustment
121.6
118.8 77.8 By-Pass Flow Port
46.4
SYMBOL
19.1
32.3

64.3

P
Inlet
148.8
62.7

70.1

Inlet

By-pass Priority
Regulated
Flow

Priority Port 49.5

2 Mtg Holes
7.1 Thru

RVXD2FV2V (Externally drained Relief Valve)


96.8
77.8 21.1
7.11

Inlet
By-Pass SYMBOL
Flow
19

Port 12 0
60.7
2

P
PR
4

Inlet
10

8
BP

70
46

REG
6.8

By-pass Priority
Regulated
2 Mtg Holes Flow
External Drain
From Relief Valve 22.9 Regulated Port Threaded
M8 x 1.25
49.5

3
Quality Hydraulic Components from the Webtec Range

CK2FV2V (Internal Check Valve between the Priority and Inlet Flow Ports)

Minimum Adjustment
121.6
118.8 77.8 By-Pass Flow Port
46.4 SYMBOL
32.3 P Inlet

7.2

64.3
148.8
62.7

70.1
Inlet

By-pass Priority
Regulated
Flow

Priority Port 49.5

2 Mtg Holes
7.1 Thru

AC2FV2V (Internal Anti-cavitation Check Valve between the By-pass and Priority Flow Ports)

Minimum Adjustment
121.6
118.8 77.8 By-Pass Flow Port
46.4 SYMBOL
P Inlet
32.3

7.6

64.3
148.8
62.7

70.1

Inlet

By-pass Priority
Regulated
Flow

Priority Port 49.5

2 Mtg Holes
7.1 Thru

4
Quality Hydraulic Components from the Webtec Range

SECTIONED VIEW Circuit 1


2FV2V Variable
Flow Dividers
Priority
Hydraulic
Regulated
Motor
Flow

By-pass
P Inlet

Circuit 2 Hydraulic
Motor

CIRCUIT SUGGESTIONS

1 Variable Speed of Hydraulic Motor


Drive on Agricultural Tractor
This circuit gives the capability to vary
the speed of a hydraulic motor as
Priority Regulated Flow
required. Also, for a given control knob P Inlet
setting, the hydraulic motor speed stays By-pass
constant regardless of the tractor
speed. 2FV2V Variable
Flow Divider
2 Two Circuits From a Single Pump
Using only one pump, this circuit gives Hydraulic
speed control of the hydraulic motor Cylinder
and powers a hydraulic cylinder. Each
function can be used either
simultaneously or independently
because pressure variations between
regulated and by-pass flows do not
effect the flow on the regulated circuit.

3 Multiple Circuits From a Single Circuit 3


Pump Hydraulic
Using one pump, this circuit gives Motors
Reg.
independently variable speed drive
from three hydraulic motors. Motors P Inlet
By-pass
can be used simultaneously or
independently. Reg.

By-pass
Reg.

By-pass
2FV2V Variable
Flow Divider

5
Quality Hydraulic Components from the Webtec Range

4. Simplify your circuit with the Circuit 4a


CK2FV2V
a) In this circuit a 2FV2V is used and Priority
Regulated
two directional control valves are Flow
required. This is because flow
cannot be reversed through the
priority port of the standard valve.

P Inlet By-pass

b) This simplified circuit uses a Circuit 4b


CK2FV2V with a built-in check valve
between the priority and inlet ports.
This allows flow to be reversed
through the priority port of the valve,
there-by reducing the number of Priority
Regulated
directional control valves required. Flow

P
Inlet By-pass

5. Protect your motors from Circuit 5


cavitation with the AC2FV2V
In this application the check valve is
Priority
routed between the by-pass and Regulated
priority ports, preventing cavitation Flow

on the priority flow.

P
Inlet By-pass

6
Other priority flow control valves
VFD50 series
A 50 lpm version of the 2FV2V series, available in
two priority sizes, 0 15 & 0 30 lpm. Can be 3/8
BSP or NPT ported, also available as 4-bolt manifold
mount.

2FV2V-E & FDM Series


(Electric and proportional control valves)
Two models available, one with electric motor
control, the other with full proportional control.
Porting, flow and functional options are the same as
the **2FV2V.

FVDVRV series
A variable priority flow divider with built-in manual
diverter valve for the priority flow. Available with
pressure relief valve.

Webtec Products Limited


Nuffield Road, St. Ives, Cambridgeshire, PE27 3LZ, UK
Tel: +44(0)1480 397400 Fax: +44(0)1480 466555
E-mail: sales@webtec.co.uk
See us at: www.webtec.co.uk
Certificate No.8242
Webtec Products Limited reserve the right to make improvements and changes to the specification without notice.