Sinusoidal Voltages and Currents:
Effective Value = 0.707 Peak Value
Average Value = 0.636 Peak Value
P = 120f/N
Here, f = Frequency, N = Speed of Rotation (RPM), P = Number of Poles, 120 = Time constant.
Power Factor (PF):
V = P/I = IR = (RP)
I = V/R = P/I = (P/R)
P = VI = V2/R = I2R
AC Circuit:
Inductive Reactance, XL = 2fL = L (ohm)
Capacitive Reactance, XC = 1/2fC = 1/C (ohm)
Impedance, Z = R+jXL (R-L Series ckt)
Impedance, Z = R- jXC (R-C Series ckt)
Impedance, Z = R+j(XL XC) = R2+(XL XC)2 [R-L-C Series ckt]
Q-Factor = 1/R(L/C)
Resonance Condition, XL = XC Power Factor = 1
V = IZ
I = V / Z = YV
Admittance, Y = 1/Z = 1/R + j (1/XC 1/XL) = 1/R + j (C 1/L)
Y = G + j B (Here, conductance G = 1 / R represents the real (conductive) component and B = ( BC BL
) is the imaginary (reactive) part)
1 kW = 1.341Hp
1Hp = 0.746 kW
Hp= Horsepower, kW = Kilowatt
VA = VxI
Watt = VICos
VAR = VISin
Single Phase power:
Full load copper loss 400W, in half load copper loss is: 400x (1/2)2
Auto Transformer:
Transformed Power = Delivered Power x (1-a)
Slip, %S = {( NS NR ) / NS }x100
S NS NR ) / NS
=(
S = fr/f
NR = 120f (1-S)/P
NS = 120f /P
fr = S x f
(NS = Synchronous Speed RPM, Nr = Rotor Speed RPM, f= Frequency, P = No. of Pole, S = SLip)