Вы находитесь на странице: 1из 1

6 5 10

4 3 2 1
6 5 4 3 2 1 S-103

Roof Beam 3 Level 11 Roof Beam 3 Level


6000 S-103 6000

Roof Beam 2 Level


Roof Beam 2 Level
5100
5100

Roof Beam 1 Level


3600 Roof Beam 1 Level
3600

Finish Floor Level


500
5 Truss Frame Elevation
NGL
A B C S-103
NOT TO SCALE
0
Top of Wall Footing 7000
-300 3500 3500
A B
Top of Foundation 3500
1 Longitudinal Framing Section -1000 1

2000
S-103
1 : 85

1400

1087
C6x8.2 STRUT
2 2

3000

3000
C6x8.2 STRUT
3 3

TRUSS-1

TRUSS-1
3000

3000
14000
C6x8.2 STRUT
4 4

1200
ROOF FRAME - 1

ROOF FRAME - 1

ROOF FRAME - 1
3000
7 Roof Plan 2
5 C6x8.2 STRUT S-103
1 : 125

3000
C-Purlins LC 100x50x15x2.0MM

2200
Channel C6x8.2 ROOF FRAME
Channel C4x5.4 FRAME STRUT

2 Typ. Beam Details 1100 1100


Channel C6x8.2 FRAME COLUMN

Beam Support
S-103
NOT TO SCALE
6 Roof Plan 1 3D Roof Frame
S-103
1 : 125 12 Connection Detail 14
S-103
NOT TO SCALE
200 200 200 200
S-103
NOT TO SCALE

TOP BARS: 2PCS - 16MM TOP BARS: 2PCS - 16MM TOP BARS: 3PCS - 12mm TOP BARS: 2PCS - 12mm
VERTICAL AND WEB:
TOP AND BOTTOM CHORD:
300

300

L 40x40x3
6 5 4 3 2
400

400

L 65x65x5mm
BOT BARS: 2PCS - 12mm BOT BARS: 3PCS - 12mm

BOT BARS: 2PCS - 16MM BOT BARS: 2PCS - 16MM


AT SUPPORT AT MIDSPAN
4 3 C-PURLINS LC
100x50x15x2.0
2 2200 3000 3000 3000 3000 1400

MM @600MM
AT SUPPORT AT MIDSPAN 110
12
O.C. C-PURLINS LC
S-103
110 100x50x15x2.0MM
STIRRUP: 10MM SPACED @ @ 600MM O.C.
1031

C6x8.2
220

1-50MM
STIRRUP: 10MM SPACED @ 10-100MM
C6x8.2
1-50MM REST @ 150MM C6x8.2

151
C6x8.2
320

10-100MM
REST @ 150MM C6x8.2
1067 1067 1067 1067 1067 1067 C6x8.2
1009 6400 1000

Beam B1 Details 4 Beam B2 Details


3
S-103
NOT TO SCALE 10 Truss-1 Frame Detail 11 Roof Frame-1 Details
S-103
NOT TO SCALE S-103
NOT TO SCALE S-103
NOT TO SCALE

DESIGNER NOTES ENGINEERING PROJECT TITLE AND LOCATION CLIENT'S NAME SHEET CONTENT SHEET NO
THESE DRAWINGS AS INTRUMENT OF SERVICE, ARE THE PROPERTY

Proposed Ice Plant


AND DOCUMENTS OF THE ARCHITECT / ENGINEER WHOSE SIGNATURE
AND SEAL APPEARS HEREIN; AND AS SUCH, IT WOULD BE UNLAWFUL JOHN IVAN P. GUEVARRA AS SHOWN
IF REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THE

S-103
WRITTEN CONSENT OR PERMISSION FROM THE AFOREMENTIONED
CIVIL ENGINEER

PRC NO. : VALIDITY DATE :


AUTHOR.

-ALL MEASUREMNTS ARE TO BE VERIFIED ON SITE BY THE


This document is void without the Engineer's Sign and Seal

PRC NO. : 0118658 VALIDITY DATE : JUNE 30, 2019


Commercial Building Sarah R. Bautista REVISION NO.:

DRAWN BY.: JDG


REVISION DATE:

DATE PLOTTED:
CONTRACTOR.
-ALL DESCREPANCIES ARE TO BE IMMEDIATELY REPORTED TO THE
PTR NO. : DATE ISSUED. : ARCHTECT, ENGINEER AND PROJECT MANAGER. PTR NO. : 7141831 DATE ISSUED. : MAR. 14, 2017 CHECKED BY.: IPG DATE CHECKED:
-CONTRACTOR ARE TO PREPARE AND SUBMIT SHOP DRAWINGS TO LOT 1043-C-2-F-7 BRGY. GUISGUIS-TALON, SARIAYA, QUEZON
PLACE ISSUED : TIN NO. : ARCHITECT AND ENGINEER BEFORE COMMENCEMENT OF WORK. PLACE ISSUED : TERESA, RIZAL TIN NO. : 422-592-338-000 APPROVED BY.: IPG DATE APPROVED: