Вы находитесь на странице: 1из 10

STORMWATER RETENTION / DETENTION

PIPE SYSTEM SIZING WORKSHEET

THE MOST ADVANCED NAME IN DRAINAGE SYSTEMS


Version 7.8
Project Name:
Enter or Select values in the Yellow fields ONLY Location (City, State):
UNITS Prepared For:
Imperial Metric
Unit of Measure TRUE FALSE Date Prepared:
(ft, in) (mm, m)
SYSTEM Engineer:
Joint Type Plain
PlainEndEnd
ST ST Contractor:
Design Storage Volume 4356 CF Regional Engineer:
Average Cover Height4 2.00 FT FALSE Area Sales Representative:
Surface Application:

HEADER LATERALS BACKFILL

Lateral Lateral # of A non-perforated system has been selected


Approx. Length
Diameter Length Number of Sticks /
of End Stick
Header Diameter 60
60 (in) (ft) Laterals Lateral Stone Porosity? 40 % no
Number of Headers 22 Group 1 60 60 114 2 6 16.8-ft *Enter "0" to not include the backfill in the storage volume

Perforate Headers? No
No Group 2 60 60 0 0-ft
Include Header(s) in No Group 3 Additional Stone
Storage Volume?
No 60 60 0 0-ft
Layer Allowing
Storage (ASV)? 4 in.
Perforate Laterals? No
No

STORAGE VOLUME APPROXIMATE SYSTEM EXCAVATION


COMPONENT SIZE Disturbed
Total Pipe Excav- Estimated
Product Width Length Surface ASV
Stone ASV System Width Length Diameter ation2 Backfill3
Volume Area
(CF) (CF) (CF) (CF) (FT) (FT) (IN) (FT) (FT) (SYD) (CYD) (CYD) (CYD)
Group 1 4,402 0 0 4,402 13 127 60 16 130 232 619 456 0
Group 2 0 0 0 0 0 0 60 0 0 0 0 0 0
Group 3 0 0 0 0 0 0 60 0 0 0 0 0 0
TOTALS 4,402 0 0 4,402.47 232 619 456 0
101.1% of the required storage
NOTES
1 - Full Stick: Assumed a standard lay length of 19'-8".
2 - Excavation: Based on manufacturer's recommended trench width and
bedding depth. Estimated volumes assume a flat system based on the user-
entered Average Cover Height.
3 - Backfill: Does not account for pipe corrugations - calculated for conservative CLICK HERE To view & download CAD files from ADS
quanitites. Not for use with take-offs or ordering purposes.
4 - Cover Height: For traffic installations, 1-ft of minimum cover is required for
diameters 12-36", 2-ft for 42-60". Maximum cover shall not exceed 8-ft without
consulting Applications Engineering. This Excel spreadsheet isprovided for rough estimating purposes only. This tool is intended to
5 - Bill of Materials: Does not differentiate between ST and WT fittings or assist the design engineer in sizing stormwater management systems using ADS pipe and manifold
between A and H profile connections. Determined on a project-specific basis. components. As with any calculation aid, this tool should be used for estimating only; the engineer
must verify the assumptions and methods to ensure they satisfy the project and local design
6 - Quantities: Assumes all Groups are same diameter. Run separate criteria.
calculations to determine quantities and costs for different Group diameters.
QUANTITIES PIPE PROPERTIES BACKFILL PROPERTIES INSTALLATION RECOMMENDATIONS
Approx Quantity of Pipe Information Stone Porosity Pipe Bedding Dist. From Pipe OD
Pipe Needed for DSV OD/ Width Volume 40% 35% 30% Diameter Depth to Trench Wall
ft in cf/lf cf/lf cf/lf cf/lf in in
ID (m) ID (mm) (m3/m) (m3/m) (m3/m) (m3/m) ID (mm) (mm)
12-in 5,410 12-in 14.2 0.81 0.85 0.74 0.63 12-in 4 12
(300-mm) 1,649 (300-mm) (361) (0.07) (0.08) (0.07) (0.06) (300-mm) (102) (305)
15-in 3,559 15-in 17.7 1.22 1.06 0.93 0.79 15-in 4 12
(375-mm) 1,085 (375-mm) (450) (0.11) (0.10) (0.09) (0.07) (375-mm) (102) (305)
18-in 2,465 18-in 21.5 1.78 1.40 1.22 1.05 18-in 4 12
(450-mm) 751 (450-mm) (546) (0.17) (0.13) (0.11) (0.10) (450-mm) (102) (305)
24-in 1,387 24-in 28.4 3.16 1.91 1.67 1.43 24-in 4 12
(600-mm) 423 (600-mm) (721) (0.29) (0.18) (0.16) (0.13) (600-mm) (102) (305)
30-in 887 30-in 35.5 4.91 3.07 2.69 2.31 30-in 4 18
(750-mm) 270 (750-mm) (902) (0.46) (0.29) (0.25) (0.21) (750-mm) (102) (457)
36-in 616 36-in 41.4 7.07 4.20 3.68 3.15 36-in 4 18
(900-mm) 188 (900-mm) (1052) (0.66) (0.39) (0.34) (0.29) (900-mm) (102) (457)
42-in 466 42-in 48.0 9.35 5.76 5.04 4.32 42-in 6 18
(1050-mm) 142 (1050-mm) (1219) (0.87) (0.53) (0.47) (0.40) (1050-mm) (152) (457)
48-in 352 48-in 54.0 12.36 6.73 5.89 5.05 48-in 6 18
(1200-mm) 107 (1200-mm) (1372) (1.15) (0.62) (0.55) (0.47) (1200-mm) (152) (457)
54-in 274 54-in 61.0 15.90 7.74 6.77 5.80 54-in 6 18
(1350-mm) 83 (1350-mm) (1549) (1.48) (0.72) (0.63) (0.54) (1350-mm) (152) (457)
60-in 226 60-in 67.3 19.31 8.49 7.42 6.36 60-in 6 18
(1500-mm) 69 (1500-mm) (1709) (1.79) (0.79) (0.69) (0.59) (1500-mm) (152) (457)
* For traffic areas

CONVERSIONS
Only enter values in the YELLOW fields
0.1 Acre-feet equals 4356 Cubic Feet
1 Cubic- Feet equals 0 Acre-Feet
1 Cubic- Feet equals 7.48 Gallons
1 Gallons equals 0.13 Cubic-Feet
1 Gallons per Day equals 0 Cubic-Feet per Second
1 Gallons per Minute equals 0 Cubic-Feet per Second
1 Cubic-Feet per Second equals 448.86 Gallons per Minute
1 Cubic-Feet per Second equals 646358.4 Gallons per Day
1 Feet of Water equals 0.43 PSI
1 Cubic Feet equals 0.04 Cubic Yards
1 Cubic Yards equals 27 Cubic Feet
1 Sqaure Feet equals 0.11 Square Yard
1 Square Yard equals 9 Sqaure Feet
1 Square Inches equals 0.01 Square Feet
1 Square Feet equals 144 Square Inches
Error: When trying to select values from the drop-down boxes or trying to click a bottom, nothing
happens (e.g. the drop-down list is not shown or the box/button is highlighted).
Solution: Security settings in Excel may be set too high. Follow the steps below to check your
settings.

1. In Excel, go to the Tools menu, then Options.

2. Click on the Security tab and click on Macro Security at the bottom of the page.
3. This window will Macro security levels; if not already set at Medium, change the settings to Medium
and select OK to exit all windows. If already set at Medium (or Low), the error you are encountering
while using the spreadsheet is not related to the security settings.

4. Restart Excel. Click Enable Macros when prompted during restart.


QUOTATION
TO PLACE ORDERS: ____________________
PH: 800-733-9987 Page 1 of 1 ____________________
FAX: 800-733-1974 Ph: _________________
Fax:_________________

JOB NAME:, GROUP 1 QUOTE DATE: August 3, 2010


LOCATION: 0 COUNTY: CONTRACTOR(S):
CUSTOMER: ENGINEER:
SALESMAN: #
CONTACT: BID DATE:
PHONE: FAX:
SUBJECT TO THE FOLLOWING CONDITIONS:

PRICES QUOTES ARE BASE ON THE TOTAL PROJECT. ADS RESERVES THE RIGHT TO RE-QUOTE WHEN THE QUANTITIES CHANGE MORE THAN 10%. SPECIFIC PRODUCTS SUCH AS NYLOPLAST
DRAIN AND CATCH BASINS, FABRICATED FITTINGS, AND SPECIALTY FABRICATIONS WILL BE OFFERED ONLY AS AN ENGINEERED SYSTEM WITH ADS PIPE. THE QUANTITIES LISTED ARE
ESTIMATES BASE ON OUR INTERPRETATIONS OF THE PROJECT QUANTITIES. PRICES GUARANTEED FOR ACCEPTANCE WITHIN THIRTY DAYS FROM ABOVE QUOTATION DATE. AFTER THIRTY DAYS
ADS RESERVES THE RIGHT TO ADJUST PRODUCT PRICING. ORDERS RECEIVED FROM VALID QUOTES MUST BE SHIPPED WITHIN THIRTY DAYS, OR ADS RESERVES THE RIGHT TO ADJUST PRICING.
ALL RETURNS SUBJECT TO A 25% RESTOCKING FEE. FITTINGS AND SPECIAL ORDER ITEMS CANNOT BE RETURNED. PRICES QUOTED DO NOT INCLUDE STATE, LOCAL, OR USE TAXES.
TECHNICAL CERTIFICATION IS AVAILABLE BY REQUEST. QUANTITIES LISTED ARE ESTIMATED. THE BIDDER IS RESPONSIBLE FOR CONFIRMING QUANTITIES. PRODUCTS LISTED ARE FOR
QUOTING PURPOSES. ADS DOES NOT IMPLY THAT THE MATERIAL WILL BE ACCEPTED ON ANY SPECIFIC PROJECT FOR JOBSITE UNLESS STATED OTHERWISE.

THIS QUOTE MUST BE ACCEPTED AND DELIVERED WITHIN 30 DAYS OF ABOVE QUOTATION DATE OR ADS RESERVES THE RIGHT
TO ADJUST PRICING.
UNIT
ITEM # QTY. UNIT DESCRIPTION PRODUCTPRICE
# TOTAL
1 228 LF 60" IB Pipe, Non-Perf ST (Group 1) $- $-
2 4 EACH 60" 90 Bend Manifold (Group 1) $- $-
3 - EACH 60" Triple Manifold (Group 1) $- $-
4 - EACH 60" Double Manifold (Group 1) $- $-
5 - EACH 60" Single Manifold (Group 1) $- $-
6 6 EACH 60" Couplers ST (Group 1) $- $-
7 - EACH 60" End Caps (Group 1) $- $-
8 670 SY Filter Fabric (Group 1) $- $-
9 $- $-
10 $- $-
11 $- $-
12 $- $-
13 $- $-
$- $-
TOTAL PAGE 1 $-
P.O. #: REQUESTED SHIP DATE:
BILL TO: SHIP TO:

FIELD CONTACT:
FIELD PHONE #:

COMMENTS:
APPROXIMATE SYSTEM LAYOUT - GROUP 1
60-in system with 2 laterals, 114-ft long

13-ft 16-ft

EXCAVATION LIMITS

127-ft

130-ft

Schmatic is for system dimension information only. Laterals (4) are depicted for illustration only - actual number of laterals is
indicated above. Clean-outs, risers, and other add-ons maybe recommended but are not shown in this schematic
QUOTATION
TO PLACE ORDERS: ____________________
PH: 800-733-9987 Page 1 of 1 ____________________
FAX: 800-733-1974 Ph: _________________
Fax:_________________

JOB NAME:, GROUP 2 QUOTE DATE: August 3, 2010


LOCATION: 0 COUNTY: CONTRACTOR(S):
CUSTOMER: ENGINEER:
SALESMAN: #
CONTACT: BID DATE:
PHONE: FAX:
SUBJECT TO THE FOLLOWING CONDITIONS:

PRICES QUOTES ARE BASE ON THE TOTAL PROJECT. ADS RESERVES THE RIGHT TO RE-QUOTE WHEN THE QUANTITIES CHANGE MORE THAN 10%. SPECIFIC PRODUCTS SUCH AS NYLOPLAST
DRAIN AND CATCH BASINS, FABRICATED FITTINGS, AND SPECIALTY FABRICATIONS WILL BE OFFERED ONLY AS

THIS QUOTE MUST BE ACCEPTED AND DELIVERED WITHIN 30 DAYS OF ABOVE QUOTATION DATE OR ADS RESERVES THE RIGHT
TO ADJUST PRICING.
UNIT
ITEM # QTY. UNIT DESCRIPTION PRODUCTPRICE
# TOTAL
1 - LF 60" IB Pipe, Non-Perf ST (Group 2) $- $-
2 - EACH 60" 90 Bend Manifold (Group 2) $- $-
3 - EACH 60" Triple Manifold (Group 2) $- $-
4 - EACH 60" Double Manifold (Group 2) $- $-
5 - EACH 60" Single Manifold (Group 2) $- $-
6 - EACH 60" Couplers ST (Group 2) $- $-
7 - EACH 60" End Caps (Group 2) $- $-
8 - SY Filter Fabric (Group 2) $- $-
9 $- $-
10 $- $-
11 $- $-
12 $- $-
13 $- $-
$- $-
TOTAL PAGE 1 $-
P.O. #: REQUESTED SHIP DATE:
BILL TO: SHIP TO:

FIELD CONTACT:
FIELD PHONE #:

COMMENTS:
QUOTATION
TO PLACE ORDERS: ____________________
PH: 800-733-9987 Page 1 of 1 ____________________
FAX: 800-733-1974 Ph: _________________
Fax:_________________

JOB NAME:, GROUP 3 QUOTE DATE: August 3, 2010


LOCATION: 0 COUNTY: CONTRACTOR(S):
CUSTOMER: ENGINEER:
SALESMAN: #
CONTACT: BID DATE:
PHONE: FAX:
SUBJECT TO THE FOLLOWING CONDITIONS:

PRICES QUOTES ARE BASE ON THE TOTAL PROJECT. ADS RESERVES THE RIGHT TO RE-QUOTE WHEN THE QUANTITIES CHANGE MORE THAN 10%. SPECIFIC PRODUCTS SUCH AS NYLOPLAST
DRAIN AND CATCH BASINS, FABRICATED FITTINGS, AND SPECIALTY FABRICATIONS WILL BE OFFERED ONLY AS

THIS QUOTE MUST BE ACCEPTED AND DELIVERED WITHIN 30 DAYS OF ABOVE QUOTATION DATE OR ADS RESERVES THE RIGHT
TO ADJUST PRICING.
UNIT
ITEM # QTY. UNIT DESCRIPTION PRODUCTPRICE
# TOTAL
1 - LF 60" IB Pipe, Non-Perf ST (Group 3) $- $-
2 - EACH 60" 90 Bend Manifold (Group 3) $- $-
3 - EACH 60" Triple Manifold (Group 3) $- $-
4 - EACH 60" Double Manifold (Group 3) $- $-
5 - EACH 60" Single Manifold (Group 3) $- $-
6 - EACH 60" Couplers ST (Group 3) $- $-
7 - EACH 60" End Caps (Group 3) $- $-
8 - SY Filter Fabric (Group 3) $- $-
9 $- $-
10 $- $-
11 $- $-
12 $- $-
13 $- $-
$- $-
TOTAL PAGE 1 $-
P.O. #: REQUESTED SHIP DATE:
BILL TO: SHIP TO:

FIELD CONTACT:
FIELD PHONE #:

COMMENTS: