Summary:
Currently there are two schemes for multi-shelf cascading of SS. SSN and SSNI can realize the
cascading of 3 shelves or less than 3 shelves; for the cascading of more than 3 shelves, please
select CSN to realize it. This text principally introduces CSN networking mode and SSN
networking mode.
.1 CSN Networking
Configuration of DIP on backplane: the difference between new shelf and the old one is that DIP is
added beside the 20 slots at the back of the new shelf, and old shelf does not have DIP. The shelf type is 1;
to be compatible with the original shelf, the fist shelf of the new shelf is turned to 3; the sub-shelves are all
turned to 1.The fist shelf type is 3 (0011b binary); other sub-shelves are all turned to 1.CSN board
position: act as active and standby CSN in slot 7 and 8 in the first shelf; CSNI board position: in slot 25 of
the fist shelf.
Port 1 and port 2: cascading ports of trunk 1, used for multi-shelf cascading. During the cascading,
the ports must be connected to the cascading ports (Trunk) of the opposite shelf; when the ports are not
used for cascading, they also can be used as user ports, but please note: only one port of port 1 and port 2
can be used at one time, it must be either-or, and the left idle port must be in link down status.
Port 3 and port 4: cascading ports of trunk 2, used for multi-shelf cascading. During the cascading,
the ports must be connected to the cascading ports (Trunk) of the opposite shelf; when the ports are not
used for cascading, they also can be used as user ports, but please note: only one port of port 3 and port 4
Port 5 and port 6: cascading ports of trunk 3, used for multi-shelf cascading. During the cascading,
the ports must be connected to the cascading ports (Trunk) of the opposite shelf; when the ports are not
used for cascading, they also can be used as user ports, but please note: only one port of port 5 and port 6
can be used at one time, it must be either-or, and the left idle port must be in link down status.
Port 7 and port 8: cascading ports of trunk 4, used for multi-shelf cascading. During the cascading,
the ports must be connected to the cascading ports (Trunk) of the opposite shelf; when the ports are not
used for cascading, they also can be used as user ports, but please note: only one port of port 7 and port 8
can be used at one time, it must be either-or, and the left idle port must be in link down status.
Port 9 and port 10: cascading ports of trunk 5, used for multi-shelf cascading. During the cascading,
the ports must be connected to the cascading ports (Trunk) of the opposite shelf; when the ports are not
used for cascading, they also can be used as user ports, but please note: only one port of port 9 and port 10
can be used at one time, it must be either-or, and the left idle port must be in link down status.
Port 11 and port 12: cascading ports of trunk 6, used for multi-shelf cascading. During the cascading,
the ports must be connected to the cascading ports (Trunk) of the opposite shelf; when the ports are not
used for cascading, they also can be used as user ports, but please note: only one port of port 11 and port
12 can be used at one time, it must be either-or, and the left idle port must be in link down status.
Port 13 and port 14: cascading ports of trunk 7, used for multi-shelf cascading. During the cascading,
the ports must be connected to the cascading ports (Trunk) of the opposite shelf; when the ports are not
used for cascading, they also can be used as user ports, but please note: only one port of port 13 and port
14 can be used at one time, it must be either-or, and the left idle port must be in link down status.
Port 15 and port 16: cascading ports of trunk 8, used for multi-shelf cascading. During the cascading,
the ports must be connected to the cascading ports (Trunk) of the opposite shelf; when the ports are not
used for cascading, they also can be used as user ports, but please note: only one port of port 15 and port
16 can be used at one time, it must be either-or, and the left idle port must be in link down status.
During the multi-shelf cascading, one trunk of cascading ports (Trunk 1 to Trunk8) of local shelf
should be used to connect to one trunk of cascading ports of opposite shelf; when the status of the above
ports are changed, alarm will be reported.
During the networking, the internal cable connection between CSN and Sun, BOSS interface and
billing server.
Set the internal network port of SUN, BOSS interface and billing server as the internal network IP
168.2.X.X, then connect them to the ports 1 to 16 of CSNI board via network cables to realize the internal
connection; the billing server can be also connected to 2 1000MGE of CSNI board.
By using this connection method, we can access the intranet of softswitch directly via BOSS
interface and billing server, so this cable connection method is not recommended. We recommend you to
interconnect billing interface with billing network via NIC proxy.
For the cascading of more the 8 shelves, consider to add CSN and CSNI in the 7th shelf. For example:
Scheme12-shelf cascading:
Fig. 1.1-ZXSS10 CSN and SSN Networking Mode-1 Scheme of 12-Shelf Cascading
Port 17 to 24 of one trunk on CSNI of 1st shelf connect to port 17 to 24 on CSNI of 7th shelf.
Port 2 to 3 of one trunk on SSNI of 1st shelf connect to port 1 to 2 on CSNI of 1st shelf.
Port 2 to 3 of one trunk on SSNI of 2nd shelf connect to port 3 to 4 on CSNI of 1st shelf.
Port 3 to 3 of one trunk on SSNI of 2nd shelf connect to port 5 to 6 on CSNI of 1st shelf.
Port 4 to 3 of one trunk on SSNI of 2nd shelf connect to port 7 to 8 on CSNI of 1st shelf.
Port 5 to 3 of one trunk on SSNI of 2nd shelf connect to port 9 to 10 on CSNI of 1st shelf.
Port 6 to 3 of one trunk on SSNI of 2nd shelf connect to port 11 to 12 on CSNI of 1st shelf.
Port 2 to 3 of one trunk on SSNI of 7th shelf connect to port 1 to 2 on CSNI of 7th shelf.
Port 2 to 3 of one trunk on SSNI of 8th shelf connect to port 3 to 4 on CSNI of 7th shelf.
Port 2 to 3 of one trunk on SSNI of 9th shelf connect to port 5 to 6 on CSNI of 7th shelf.
Port 2 to 3 of one trunk on SSNI of 10th shelf connect to port 7 to 8 on CSNI of 7th shelf.
Port 2 to 3 of one trunk on SSNI of 11th shelf connect to port 9 to 10 on CSNI of 7th shelf.
(If port 2 to 3 of one trunk on SSNI of 12th shelf connect to port 11 to 12 on CSNI of 7th shelf.)
1st shelf and 7th shelf are main shelves which are configured with CSN and CSNI board, and the shelf
type is 3;
The shelves from 2 to 6 and from 8 to 11 are sub-shelves, and the shelf type is 1.
Scheme8-shelf cascading:
Port 2 to 3 of one trunk on SSNI of 1st shelf connect to port 1 to 2 on CSN of 1st shelf.
Port 2 to 3 of one trunk on SSNI of 2nd shelf connect to port 3 to 4 on CSN of 1st shelf.
Port 3 to 3 of one trunk on SSNI of 2nd shelf connect to port 5 to 6 on CSN of 1st shelf.
Port 4 to 3 of one trunk on SSNI of 2nd shelf connect to port 7 to 8 on CSN of 1st shelf.
Port 6 to 3 of one trunk on SSNI of 2nd shelf connect to port 11 to 12 on CSN of 1st shelf.
Port 7 to 3 of one trunk on SSNI of 2nd shelf connect to port 13 to 14 on CSN of 1st shelf.
Port 8 to 3 of one trunk on SSNI of 2nd shelf connect to port 15 to 16 on CSN of 1st shelf.
.2 SSN Networking
Port 1: user port, can be used to connect SUN server or background PC.
Port 2 and port 3: cascading ports of trunk 1, used for multi-shelf cascading. During the cascading,
the ports must be connected to the cascading ports (Trunk) of the opposite shelf; when the ports are not
used for cascading, they also can be used as user ports, but please note: only one port of port 2 and port 3
can be used at one time, it must be either-or, and the left idle port must be in link down status.
Port 4 and port 5: cascading ports of trunk 2, used for multi-shelf cascading. During the cascading,
the ports must be connected to the cascading ports (Trunk) of the opposite shelf; when the ports are not
used for cascading, they also can be used as user ports, but please note: only one port of port 4 and port 5
can be used at one time, it must be either-or, and the left idle port must be in link down status.
During the multi-shelf cascading, one trunk of cascading ports (Trunk 1/Trunk 2) of local shelf must
be connected to one trunk (Trunk 1/Trunk 2) of cascading ports of opposite shelf.
During the networking, the internal cable connection between SSN and Sun, BOSS interface and
billing server.
Set the internal network port of SUN, BOSS interface and billing server as the internal network IP
168.2.X.X, then connect them to the ports 1 to 5 of SSNI board via network cables to realize the internal
connection;
By using this connection method, we can access the intranet of softswitch directly via BOSS
interface and billing server, so this cable connection method is not recommended. We recommend you to
interconnect billing interface with billing network via NIC proxy.
Port 2 to 3 of one trunk on SSNI of 1 st shelf connect to port 2 to 3 (or port 4 to 5) of one trunk on SSNI of
2nd shelf.
Port 2 to 3 of one trunk on SSNI of 1 st shelf connect to port 2 to 3 (or port 4 to 5) of one trunk on
SSNI of 2nd shelf.
Port 4 to 5 of one trunk on SSNI of 1 st shelf connect to port 2 to 3 (or port 4 to 5) of one trunk on
SSNI of 3rd shelf.
Summary:
The chapter mainly introduces softswitch hardware cable connection specification, including
cascading for single-shelf or multi-shelf SS1B via SSNI, cascading for multi-shelf SS via CSN
and inter-rack monitor cables for cascading.
Fig. Softswitch Hardware Cable Connection Specification-2 SSNI Cable Connection for SS1B
Network cable of NIC: the NICs in 26 slot and 27 slot are for service+disaster heartbeat (if there is no
Fig. Softswitch Hardware Cable Connection Specification-3 Network cable 1 of NIC in SS1B
Explanations:
1. If there is no special NIC to transfer billing message, then the second Ethernet port of the billing
server should be started. The billing server is connected to the corresponding billing network, the
firewall between the billing server and the billing network should be set in order to guarantee the
safety of the billing server;
2. If there is no special NIC to transfer NMS message, then the internal network management mode can
be used, the NIC is shared by NMS message and service message.
Fig. Softswitch Hardware Cable Connection Specification-4 CSN Cascading for SS1B
Network cable of NIC: the NICs/GNICs in 26 slot and 27 slot are for service+disaster heartbeat (if there is
no disaster environment, then there is no disaster heartbeat message); the NICs in 28 slot and 29 slot are
for NMS and billing message. The NICs in 28 slot and 29 slot can be configured as the active and standby
NICs or the independent NICs as required on site.
As shown in following figure: (The NICs in multi-shelf SS are configured as the active and standby NICs.
The NMS and the billing message use one pair of NICs respectively or they share a pair of NICs)
Fig. Softswitch Hardware Cable Connection Specification-5 Network cable 2 of NIC in SS1B
Inter-rack monitor cables of cascading: connect the RS458 port of the power box at the top of the first rack
(view from the back of the rack, the RS458 port is on the very left of the power box) to the RS485 port of
the power box at the top of the second rack via the original cable, then connect the RS485 port of the
power box at the top of the second rack to the RS485 port of the power box at the top of the third rack, and
so on to the last rack.
Suppose there are two racks in SS1B. The number of the controlling rack is K1 and the other one is K2.
The cascading of inter-rack monitor cables is as shown in following figure:
Summary:
This chapter mainly introduces DIP switch and cascading cable connection of SS. Please note
during the commissioning.
.1 SS DIP Switch
If there are more than 3 shelves in SS, the shelf DIP switch is as follows:
Fig. SS DIP Switch and Cascading Cable Configuration-7 DIP Switch in Main-Control Shelf
Note:
Turn on for 0 and turn off for 1.The same applies below.
Fig. SS DIP Switch and Cascading Cable Configuration-8 DIP Switch in Other Shelves
For cascading of 3 shelves or less than 3 shelves, turn 1 for every shelf, that is 0001.
Fig. SS DIP Switch and Cascading Cable Configuration-9 DIP in 1st Shelf
Fig. SS DIP Switch and Cascading Cable Configuration-10 DIP in 2nd Shelf
Fig. SS DIP Switch and Cascading Cable Configuration-11 DIP in 3rd Shelf
For 4th shelf and 5th shelf: 0100 and 0101, etc.
The switches in the 1st shelf are all turned to 0, that is they are turned to ON; the switches in the 2 nd
Jumper 1 and jumper 5 of the last shelf should be short circuits (the jumpers are numbered from 1 to
5 from up to bottom), the other 3 are released; set jumper 2 and jumper 4 of the other shelves to be short
circuits, and the other jumpers are released.
When DIP switches and jumpers are changed, they will become valid by pressing the restarting
button.
Fig. SS DIP Switch and Cascading Cable Configuration-12 DIP Switch and Jumper of Power P in 1st Shelf
Fig. SS DIP Switch and Cascading Cable Configuration-13 DIP Switch and Jumper of Power P in 2nd Shelf
(Here the jumpers are configured according to the real situation, if it is not the last shelf, then jumper 2 and jumper 4 are
.2 Cascading Cables of SS
Cascading is not necessary if there is only one shelf.
If there are 2 or 3 shelves, then cascading can be realized via SSNI board.
Fig. SS DIP Switch and Cascading Cable Configuration-14 Cascading Realized via SSNI Board
Port 2 and port 3 of the 1 st shelf are connected to port 4 and port 5 on SSNI board of 2 nd shelf; port 4
and port 5 are connected to port 4 and port 5 on SSNI board of 3 rd shelf, then the 3-shelf cascading is
realized.
If there are more than 3 shelves, CSN board must be used to realize the cascading. There are 2
TRUNK interfaces and 8 pairs of cascading cables on the backplane, so 8 shelves can be cascaded. Please
note the sequence of cables cannot be wrong. FE1 and FE2 must be used together to connect port 4 and
port 5 on SSNI board of 1st shelf, FE3 and FE4 are connected to port 4 and port 5 on SSNI board of 2 nd
shelf, and so on.
Also please note the cascading cable used is C-ETH-006 which looks the same as the cascading cable
of MSG9000, but the labels on the cables are different.
.3 Monitoring Cables of SS
ZXSS10 SS1b monitoring includes environment monitoring, fan monitoring and power P monitoring.
Now we take shelves K1 and K2 as examples to introduce each monitoring cable.
Fig. SS DIP Switch and Cascading Cable Configuration-15 Power P Monitoring Cables