SUB: Monthly report on the working of 10Kw FM IGNOU


TRANSMITTER for the Month of Jul 2014

Sir,

Find enclosed herewith the above cited subject report for your kind
perusal and further action please.

Yours faithfully

( Bal krishna)
Assistant Director (Engg.)
For Deputy Director
General(E)

Copy to:1. The General Manager,AIR Resources(Kind Attn: Shri


A.K.Taneja) DG AIR Akashwani Bhavan, Parliament
Street,
New Delhi-110011.
2. Director EMPC(By name: Shri K. Ravikant) IGNOU Gyanvani
Maidan Garhi, New Delhi-110068

1
MONTHLY REPORT ON THE WORKING OF 10 KW FM TRANSMITTER
OF IGNOU GYAN VANI CHANNEL FOR THE MONTH OF JULY2014
PART A

Monthly Report of IGNOU Transmitter for the Month of Jul 2014

Name Transmission Power Diesel


Total Break Down due to (if any)
Tr. Hours Consumption usage
of Station Transmission
Power of Tr. Remarks
Hrs during
(KW) Power Total
From To month Hours Lts. Gear Other
KW Supply B/D

IGNOU
Gyanvani
02
Txr 28 P.S.F.
Hrs 15 07 07
10kw 0800-2000 372 Hrs mnts
Nil Nil
mnts
Approx 36 Lts
At
Mnts
Pitampura

2
PART B
STATION NAME : IGNOU GYANVANI Transmitter
CITING : FM Pitampura
TRANSMITTER TYPE :

Make & Type BE FM 10 S

Date of Commissioning March 2003

Frequency 105.6 MHz

Actual Power Transmitted 05KW

Total monthly consumption of electricity by 8520 Units


IGNOU Transmitter

Status of DG set and A/Cs DG Working OK, Window AC 3 nos


& Two Split AC faulty

General routine maintenance of the transmitter Done regularly

Scheduled program hours Monthly Progressive

Hours of Programme 372 Hrs 1464 Hrs

Testing hours 07:45 Hrs 30:30 Hrs

Total Hours of working 379:45 Hrs 1494:45 Hrs

Frequency Deviation, if any, reported by any


Nil
agency

Working of interlock O.K.

INTERRUPTION

Monthly Progressive

Gear Nil Nil

Power supply 07 Mts 20 Mts

Other causes Nil Nil

Total (Hrs. ) 07 Mts 20Mts


3
Total (%) 0.0313% 0.0227%

Remarks: Nil
LOW POWER OPERATION (HOURS), IF ANY:- Nil

Exciter Make and Type Fxi 60

Exciter in circuit 1 Nos

Deviation (KHz) 75 KHz

Audio Level (dBm) 0 dBm

Power (W) 24 W

POWER AMPLIFIER

Module FORWARD POWER REFLECTED PANEL METER READING


Nos. (W) POWER
(W)

1 Low power - 05KW

2 265 1

3 316 1

4 339 0

5 394 1

6 335 0

7 316 1

8 290 0

9 High Reflected

10 371 0

11 369 0

12 346 0

13 324 0

14 316 0

15 311 0

4
16 326 0

IPA 371 0

TRANSMITTER POWER :

TRANSMITTER FORWARD REFLECTED REJECT DEHYDRATION Tx. HALL


POWER POWER LOAD PRESSURE TEMP.
(KW) (KW) (Kg/cm2 )

BE FM 10 S 05 KW 36 W - 5.8psi 25

AUTOMATIC VOLTAGE REGULATOR:

MAKE AND TYPE Sterco

CAPACITY 60 KVA

WORKING CONDITION OK

INPUT VOLTAGE OUTPUT VOLTAGE


(Volts) (Volts)

VR VY VB VR VY VB

245 242 240 218 215 218

DIESEL GENERATOR:

Make and Type Capacity Working Hours used


condition

Kirloskar 70 KVA OK 02 Hours 36 mts

COMBINER/DIPLEXER:

Make and Type Capacity Working condition

R.F.S. Pvt Ltd 25 KW O.K.

5
DUMMY LOAD:

Make and Type Capacity Working condition

Bird Electronic 15 KW OK

A/C UNITS:

Split Window
Number of Units 5 3

Make and Type Voltas 1.Amtrex(1)


2.Carrier(1)
3.Fedders Lloyd(1)

Capacity 2 Tons 1.5 Tons

Working condition 2 OK 3 Faulty


2 Faulty

ANTENNA SYSTEMS:

Make and Type

Whether on CTI Antenna


i) CTI antenna
ii) AIR antenna or
III) IGNOU antenna

Mounting Height of the antenna 210 meters Approx

Working condition OK

FAILURE OF MAJOR COMPONENTS : Three Power Amplifier , One power supply


module and one exciter faulty.

AVAILABILITY OF SPARES : a. Power Supply module 1Nos Faulty


b. Power Amplifier 1Nos Faulty
c. Front Panel PCR 1Nos
d. Assy PCB Optically coupled
Relay Tyco Electronics
Potter &Brumfield T90 series 1Nos
e. Self starter Autolek 1Nos Faulty
f. Pallets Two Nos
6
SPARES RECEIVED DURING THE MONTH : Power supply card of Exciter
Received in june 2014
IMPORTANT WORK DONE : Power supply card of faulty
Exciter replaced.

ANY OTHER POINT : Nil

THE DETAILS OF INTERRUPTION CAUSED FROM IGNOU STUDIO: 445 mnts.


CD played from this station from1510 hrs to 1910 hrs on 02.07.14 ,From 0800 hrs
to 0805 hrs on14.07.14 and From 0800 hrs to 1120 hrs on 27.07.14.

BREAK DOWN DETAILS

Month Interruption Cause Duration


caused (in Mins). Date From to

July 2014 07 02.07.14 1944 1945


PSF
05.07.14 1151 1152

09.07.14 1347 1348

09.07.14 1830 1831

09.07.14 1942 1943

12.07.14 1345 1346

24.07.14 1750 1751

Signature

7
8