Вы находитесь на странице: 1из 1

Calculation of section factors for exposed sections

For hot rolled open section, if this is exposed in fire on all four sides, the heated perimeter is given by:
Am = 2D + 4B + 2r - 8r - 2t t = Wed Thickness

Universal Beams to BS4 Part1 1993 - Dimensions & Properties


Thickness Depth Ratios for Local Buckling Second Moment of Area Radius of Gyration Elastic Modulus Plastic Modulus Heated
Mass Per Depth of Width of Buckling Torsional Warping Torsional Area of Heated
Root radius between perimeter to
Section metre section section Axis Axis Axis Axis Parameter Index Constant Constant section perimeter
Web Flange fillets Flange Web Axis x-x Axis y-y Axis y-y Axis y-y Area Ratio
Member Designation x-x y-y x-x x-x
Mark
h b s t r d b/2t d/s Ix Iy rx ry Zx Zy Sx Sy u x H J A Am Am / A
kg/m mm mm mm mm mm mm cm4 cm4 cm cm cm3 cm3 cm3 cm3 dm6 cm4 cm2 cm2
B1 152x89x16 16 152.4 88.7 4.5 7.7 7.6 121.8 5.76 27.1 834 89.8 6.41 2.1 109 20.2 123 31.2 0.89 19.6 0.005 3.56 20.3 637.55 31.41
C1 152x152x23 23 152.4 152.2 5.8 6.8 7.6 123.6 11.2 21.3 1250 400 6.54 3.7 164 52.6 182 80.2 0.84 20.7 0.021 4.63 29.2 888.95 30.44

Channels - Dimensions and Properties (1988)


Mass Per Depth of Width of Thickness Root Depth Ratios for Local Buckling Second Moment of Area Radius of Gyration Elastic Modulus Elastic NA Plastic Modulus Plastic NA Buckling Torsion Warping Torsion Area of
Heated
Section metre Section Section Radius between Parameter Index Constant Constant Section Heated
perimeter to
Member Fillets perimeter
Web Flange Flange Web Axis Axis Axis Axis Axis Axis Axis Axis Area Ratio
Mark
D B t T r d b/T d/t x-x y-y x-x y-y x-x y-y cy x-x y-y ceq u x H J A Hp Am / A
Designation Kg/m mm mm mm mm mm mm cm4 cm4 cm cm cm3 cm3 cm cm3 cm3 cm dm6 cm4 cm2 cm2
CH1 76x38x6 6.72 76.20 38.10 5.10 6.80 7.60 45.80 5.60 9.0 74.3 10.7 2.95 1.12 19.5 4.08 0.7 23.5 7.82 0.908 9.06 0.000101 1.26 8.56 281.55 32.89