Free Setup and Configuration
If an iDRN signal conditioner is not
going to be connected to a computer,
it can be ordered preconfigured by
the factory at no extra charge. The
user can select the input types,
ranges and output scale, and
OMEGA will program the instruments OPC Server
to those specific requirements in our And Active X
calibration lab prior to shipment. For Controls
custom factory setup and scaling of OMEGA offers an optional
the iDRN model, please specify the OPC Server (OLE for
-FS option. Process Control) and
ActiveX Controls for
iDRX Series Digital Output the iDRX Series. These
The iDRX Series Signal Conditioners programs make it easy to
provide highly accurate digital outputs. integrate the iDRX devices
Each module provides an RS-485 with information systems
Serial output that can be transmitted using ActiveX Containers
directly to computers and other such as Microsoft Visual Basic
devices with serial communications and Microsoft Excel as well as with
capability, or converted to Ethernet. popular OLE and OPC compliant
On an RS-485 bus, up to 32 modules data acquisition, process control,
can be connected over a distance and industrial automation software
of 1200 m (4000') on a single pair from OMEGA, Iconics,
of wires. With optional RS-485 Wonderware, Intellution,
repeaters, up to 254 modules may be Rockwell Automation, and
connected to a single RS-485 port. GE Fanuc Cimplicity among others.
The iDRX Series digital conditioners
may be connected to an RS-485 iDRX and iDRN Series
bus using either screw terminator or Common Specifications
RJ12 connector. Input Power Supply: 10 to 32Vdc Mounts to
ASCII and MODBUS iDRX Output: 2-wire (half duplex) 35 mm
DIN rails.
The user can select between an RS485 (Omega Serial Protocol
and Modbus Serial Protocol)
easy-to-use, straightforward ASCII
protocol, or the popular MODBUS iDRN Output: 0 to 10V @ 10 mA max;
0 to 20 mA or 4 to 20 mA,
protocol found in many existing 10V compliance
industrial installations. With the Isolation: 1800 Vdc peak
simple ASCII commands, writing Typical Step Response to 99%:
programs using the iDRX does not 1 second
require special drivers or libraries. In Operating Ambient:
addition, many off-the-shelf software -5 to 55C (23 to 131F)
packages can be used with the iDRX Storage Temperature Range:
devices without any programming. -40 to 85C (-40 to 185F)
OMEGA also provides a number of Mounting: 35 mm DINrail RAIL-35-2,
useful programs and demos for the Dimensions: 90 H x 25 W x 107 mm D 2 m (6') long.
iDRX at no charge. (3.54 x 0.99 x 4.21")
2
Ethernet and Internet
The iDRX signal conditioner can
also be connected to an Ethernet
network using the EIT module
as a Serial/Ethernet bridge. One
EIT module can be a hub for up
to 32 iDRX modules. The EIT
module packages the ASCII serial
communications in standard
TCP/IP Protocol for transmission
over standard Ethernet networks
and the Internet. Unlike some
manufacturers products this
system uses totally open, non-
A/IN proprietary standards and protocols
for Ethernet and Internet. The
SERIAL I/O
user can integrate these devices
with any commercial or industrial
grade networking components
that also comply with the popular
international standards.
DI/O
Get E-mail Notification of Alarm Status
on your web enabled smartphone or
Access Vital blackberry.
information
Anytime,
Anywhere.
Digital Output iDRX modules connected to Ethernet iDRX modules on RS485 Serial Bus
3
U Web Server and an Ethernet/
Serial Bridge
U Serves up to 32 devices
iServer EIT
To Order
Model No. Description
EIT-D Internet Server RS-232 serial interface without I/Os, serves one
iDRN unit
EIT-D-485 Serial to Ethernet iServer Industrial MicroServerTMwith screw
terminal serial port, serves 32 iDRX devices
iDRN-PS-1000 Power supply (switching), 95 to 240 Vac input, 24 Vdc output @
850 mA (power 7 units)
Software
OPC-SERVER LICENSE OPC server for signal conditioners
Accessories
CAT-285 Bi-directional RS232-R3485 converter for iDRX series
DB9-RJ12 DB9 to RJ12 connector adaptor, includes 2 m (7') RJ12 cord
DB25-RJ12 DB25 to RJ12 connector adaptor, includes 2 m (7') RJ12 cord
RJ12T RJ12 T split connector for RS-485 instruments, includes 2 m (7')
RJ12 cord
RAIL-35-1 35 mm (1.4") DIN rail, 1 m (3.3') length
RAIL-35-2 35 mm (1.4") DIN rail, 2 m (6.6') length
Ordering Example: EIT-D-485, serial to Ethernet industrial MicroserverTM, iDRN-PS-1000, power supply,
iDRX-TC, thermocouple conditioner, iDRX-RTD, RTD conditioner, RAIL-35-2, DIN rail, DB9-RJ12,
connector adaptor.
4
Thermocouple Signal Conditioners
OMEGA manufactures
thousands of thermocouple
probes.
iDRX-TC
5
RTD Signal Conditioners
iDRX-RTD
OMEGA
The iDRN-RTD and iDRX-RTD DI/O manufactures many
signal conditioners provide types of RTD probes.
highly accurate, stable, isolated
measurement of RTD temperature
sensors. Both models can accept Digital Output Model
2, 3, or 4 wire 100 PT, 500 PT
and 1000 PT RTDs.
The iDRX-RTD is a digital signal Specifications
conditioner which communicates Accuracy at 25C: 0.5C
2 Models (Analog or over an RS-485 communication link Input Types: Platinum RTD, 100,
Digital Outputs) using either a simple, straightforward 500 or 1000 element (2, 3 or 4 wire,
The iDRN-RTD provides a fully ASCII Serial Protocol or MODBUS 385 or 392 curve)
scalable analog output that is Serial Protocol. Up to 32 modules Resolution: 0.1C
proportional to the input signal. may be connected to a single Power Consumption: 2.4 W
The iDRX-RTD uses digital RS-485 RS-485 port stretching up to 1200 m (100mA @ 24Vdc)
communications. (4000') without repeaters.
Input Range: -200 to 850C
Ethernet Connection (328to 1562F)
Analog Digital Output The Optional EIT iServer module iDRX Output: 2-wire (half duplex)
The output of the iDRN-RTD can can connect up to thirty-two (32) RS485 (OMEGA Serial Protocol
be user set for 0 to10V, 4 to 20 mA iDRX RS-485 Signal Conditioners and MODBUS Serial Protocol)
or 0 to 20 mA. Input scaling and to an Ethernet network and the iDRN Output: 0 to 10V @ 10 mA
configuration of other operating Internet using standard TCP/IP max; 0to 20 mA or 4 to 20 mA, 10V
parameters is accomplished by protocol. The iServer can also be compliance
connecting to a standard RS-232 used as a simple Serial to Ethernet RTD Default settings iDRN:
port of a personal computer and bridge or converter to connect a Input PT100, 0.00385, 3-wire, range
using the Windows-based setup single iDRN RS-232 device to an 0 to 1000F; Output 4 to 20 mA
software. Once configured the Ethernet network and the Internet. (custom settings available at no charge)
settings may be stored in non-
volatile memory and the unit
disconnected from the PC. To Order
Factory Setup and Configuration Model No. Description
at No Extra Charge iDRX-RTD igital signal conditioner with RS-485 output for RTD
D
(iDRN Analog Output Model) temperature sensors
Please Specify:
iDRN-RTD Signal conditioner with analog output for RTD temperature sensors
Type and resistance
Temperature high and low -FS Factory setup and scaling
Output Value high and low Comes complete with operators manual.
Example: Type Pt100; 0.00385; Ordering Example: iDRN-RTD, digital signal conditioner, and DB9-RJ12, connector adaptor.
For iDRN/iDRX accessories and power supplies, please visit us online.
4-wire; 0C = 4 mA, 100C = 20 mA
6
Strain Gage/Bridge Transducer-Signal Conditioners
iDRX-ST
7
Process Inputs Signal Conditioners
iDRX-PR
U Unipolar/Bipolar 400 mV
to 10 Vdc, 0 to 20 mA dc
U 11 to 14-Bit Resolution
U 0.1% FS Accuracy
U 14 Vdc Excitation
U 1800 Vdc Isolation
U 250 Vac/1 Min Input Overvoltage
Protection
(Voltage Input Only)
U Free Setup and
Configuration Software
U Factory Setup and Configuration
Available
at No Charge (for iDRN
Analog Output Models)
8
Frequency/Pulse Digital
Signal Conditioners
iDRX-FP
Analog Output Model
The output of iDRN-PR can
be user set for 0 to 10V,
4 to 20 mA or 0 to 20 mA.
Scaling and configuration is
done with the free software
U Software Selectable on a PC using either the
Input Type standard RS-232 port, or an
U 0 to 50 KHz Frequency Input Ethernet connection with the
2 Million Pulse Capacity optional EIT module.
U Proximity, Switch, Magnetic, Once configured the settings
Pickup, NAMUR, Contact are stored in non-volatile
Closure and Open Collector memory and the unit
Input Types disconnected from the PC.
U RS-485 Output Factory Setup and Configuration
U 1800 Vdc Isolation at No Extra Charge (iDRN Analog Compatible
U Free Setup and Configuration Output signal conditioners) with the flow
sensor shown.
Software Please Specify:
U Factory Setup and Input signal or sensor type
Configuration Available at Input frequency high and low
No Charge (for iDRN Analog Output value high and low
Output Models) Excitation: 10 or 14 Vdc
SERIAL I/O
Magnetic pickup (2-wire) A/IN DI/O
Example: 0 Hz = 4 mA,
The iDRN-FP and iDRX-FP signal 1000 Hz = 20 mA, excitation N/A
conditioners provide accurate,
stable, isolated measurement of Digital Output Model
frequency and pulse signals. Both The iDRX-FP is a digital signal
models measure frequency signals conditioner which communicates
up to 50 KHz and can count up to over an RS-485 communication link Specifications
two million pulses. The iDRX-FP using either a simple straightforward Accuracy at 25C: 0.01% FS
and iDRN-FP are compatible with a ASCII Serial Protocol or MODBUS Resolution: 15 to 19bit
wide variety of transducers including Serial Protocol. Up to 32 modules
proximity, switch, magnetic pickup, Power Consumption: 2.4W
may be connected to a single
NAMUR, contact closure and open (100 mA @ 24 Vdc) without excitation,
RS-485 port stretching up to 1200 m
collector transducers. 3 W (125 mA @ 24 Vdc) with excitation
(4000') without repeaters.
Input Ranges: Frequency from
2 Models (Analog or Ethernet Connection 200 Hz to 50 KHz pulse from 20,000 to
Digital Outputs) The Optional EIT iServer module 200,000,000 pulses full scale
The iDRN-FP provides an analog can connect up to 32 iDRX RS-485 iDRX Output: 2-wire (half duplex)
output that is proportional to the input Signal Conditioners to an Ethernet RS485 (Omega Serial Protocol and
signal. The iDRX-FP uses digital network and the Internet using MODBUS Serial Protocol)
RS-485 Serial Communication. standard TCP/IP protocol. The iDRN Output: 0 to 10V @ 10 mA max;
iServer can also be used as a 0to 20 mA or 4 to 20 mA
OMEGA manufactures simple Serial to Ethernet bridge
many types of Flow FP Default Settings iDRN:
Transducers. or converter to connect a single Input 0 to 20 KHz; Output 4 to 20 mA
iDRN RS-232 device to an Ethernet (custom settings available at no charge)
To Order
Model No. Description
iDRX-FP Digital signal conditioner with RS485 output for Frequency/Pulse inputs
iDRN-FP Signal conditioner with analog output for Frequency/Pulse inputs
-FS Factory setup and scaling
Comes complete with operators manual.
Ordering Example: iDRN-FP, signal conditioner, and DB9-RJ12, connector adaptor.
For iDRN/iDRX accessories and power supplies, please visit us online.
9
AC Voltage/Current Signal Conditioners
iDRX-ACV
4 to 20 mA or 0 to 20 mA with the
free configuration software. The
modules connect to a PC with
RS-232 Serial Communications,
or by Ethernet with the optional
EIT module. Once configured the
U Software Selectable settings are stored in non-volatile
Input Ranges iDRX-ACV: memory and the unit can
0 to 400 mV to 0 to 400 Vac be disconnected from the PC.
iDRX-ACC: 0 to 10 mA to
0 to 5 A ac Factory Setup and Configuration
U 14-Bit Resolution (Max) at No Extra Charge (iDRN Analog
U 0.2% FS Accuracy Output Modules)
U 1800 Vdc Isolation Please Specify:
U Free Setup and Configuration iDRN-ACV: Input value high and
Software low; output value high and low
U Factory Setup and Example: 0 volts = 4 mA, A/IN
Configuration Available 400Vac = 20 mA
at No Charge (for iDRN iDRN-ACC: Input value high and SERIAL I/O
Analog Output Models) low; output value high and low
Example: 0 A = 4 mA, 5 A = 20 mA Specifications
Accuracy at 25C: 0.2% FS
The iDRN and iDRX Series signal Digital Output Model
conditioners provide highly accurate, Resolution: 10 to 14bit
The iDRX-ACC (Current) and Power Consumption: 2.4W;
stable and isolated measurement iDRX-ACV (Voltage) communicate
of AC voltage and current signals (100 mA @ 24 Vdc)
via RS-485 Serial Communications MODELiDRX-ACV/iDRN-ACV
across extremely wide ranges: AC using either simple ASCII Commands
Current ranges from 0 to 10 mA Input Ranges: 0 to 400 mV to
or the popular MODBUS Protocol.
through 0 to 5 A ac; AC Voltage ranges Up to 32 modules may be connected 0 to 400 Vac full scale
from 0 to 400 mV to 0 to 400 Vac. to a single RS-485 port stretching Interface:RS-485; RJ-12 or screw
Analog or Digital Outputs up to 1200 m (4000'), more with terminal connector
The iDRN-ACV and iDRN-ACC RS-485 repeaters. MODELiDRX-ACC/ACC
accept ac voltage and ac current Input Ranges: 0 to 10 mA to 0 to 5 A
Ethernet Connection ac full scale
respectively and provide an analog The optional EIT iServer module
output which is proportional to the iDRX Output: 2-wire (half duplex)
can connect up to 32 iDRX RS-485 RS485 (Omega Serial Protocol
input. The iDRX-ACV and iDRX-ACC Signal Conditioners to an Ethernet
accept ac voltage and ac current network and the Internet using and MODBUS Serial Protocol)
respectively and transmit via standard TCP/IP protocol. The iDRN Output: 0 to 10V@10 mA
RS-485 Serial Communications. iServer can also be used as a max; 0to 20 mA or 4 to 20 mA
Analog Output Model simple Serial to Ethernet bridge ACC Default Settings iDRN:
The Analog Output models can be or converter to connect a single Input 0 to 5 Amp; Output 4 to 20 mA
configured for outputs of 0 to 10 Vdc, iDRN RS-232 device to an Ethernet (custom settings available at
network and the Internet. no charge)
MFO Series,
$20 (basic unit).
RCT Series,
$20 (basic unit). To Order
Model No. Description
iDRX-ACC Digital signal conditioner with RS485 output for ac current input
iDRX-ACV Digital signal conditioner with RS485 output for ac voltage input
iDRN-ACC Signal conditioner with analog output for ac current inputs
OMEGA offers many iDRN-ACV Signal conditioner with analog output for ac voltage inputs
types of Current
Transformers. -FS Factory setup and scaling
Comes complete with operators manual.
Ordering Example: iDRN-ACV, signal conditioner, and DB9-RJ12, connector adaptor.
10