*420
Eyepiece
Field Number (FN)
WHB10 20
160 245
233
* The length marked with an asterisk (*) may vary according to interpupillary distance. Distance for figure shown is 62 mm.
Conventional Conventional
objective objective
PLCN10 PLCN40
1
Excellent cost-performance in reflected light fluorescence Dependable basic performance assures
and other observation methods outstanding operational convenience
Move the specimen with just one finger Tilting binocular tube / U-CTBI
Rubber grips are provided for the stage The tilting binocular tube lets each operator
handles, allowing the specimen to be moved select the most suitable and comfortable
smoothly with just one finger. The slim body eyepoint a valuable contribution to
and conveniently positioned controls ensure reducing fatigue in extended observation
that everything is within easy reach, so sessions.
operators can maintain a natural posture.
Slide condenser / CX-SLC Inward-facing quintuple revolving Rackless stage with enhanced
Brightfield condenser / CH3-CD Darkfield central stop / CH2-DS
For darkfield observations from 4x to 40x. nosepiece operability
These Abbe type condensers allow The quintuple revolving nosepiece enables a To keep the work area clear, and to avoid
* Separate filter holder (CH2-FH) or attachment lens (CX-AL)
brightfield observations from 4x to required. wide range of magnification observations interference with observation operations,
100x. Accurate centering is provided by and various combinations of objectives. the X-direction travel guide does not extend
the attachment lens (CX-AL) and the iris Unrestricted access to the space in front of out from the side of the stage. The main
diaphragm, to exclude unnecessary the objective allows specimens to be and sub-scale displays are designed for
light and obtain bright Koehler exchanged quickly and easily. easy read-out.
illumination right across the
magnification range. These highly
economical condensers enable phase
contrast and darkfield observations by
simply adding basic accessories.
Low magnification adapter /CX-LA
Use of the 2x low magnification objective allows
macro observation.
3 4
More accessories, more observation versatility
U-CBI30-2 U-CTR30-2
Binocular tube Trinocular tube
PLCN Objectives
Other UIS2 Objectives
2x magnification changer/ U-ECA
Magnification is doubled by engaging the CX-RFA-2
auxiliary 2x lens. Reflected light U-LH50HG U-RFLT50
fluorescence attachment Lamp house for Power unit
50 W Hg
CX-PCD
Phase contrast
condenser
U-DO3
Trinocular tube/ U-CTR30-2 Dual observation attachment
stunning detail in real time. Seamless of the pencil and drawing surface into the
conference support with real-time visual field.
U-EPA2
image display and smooth operation. CH2-FH CH3-CDP Eyepoint adjuster
Filter holder Simple
polarizing
U-DA condenser
U-ECA
Magnification changer 2x
U-DAL10
CX-AL CH3-CD
Attachment Brightfield
lens condenser
Trinocular intermediate attachment/
U-TRU U-APT
A binocular tube on its own allows digital Arrow pointer
imaging in combination with this trinocular CX-LA CX-SLC
Low magnification Slide condenser
intermediate attachment. adapter
U-POT CH3-CH
32.5 filter
Polarizer CX41RF/CX41LF Cord rest
Microscope frame
CH2-DS Rubber grip
45 filter
Darkfield central stop (standard equipment
of the microscope frame)
*1 Please consult your Olympus dealer for detail. *2 U-TV1 cannot be attached for technical reason. Combine U-TV1-2 for 1x adapter. *3 10x eyepieces incorporated. FN 18
CX41+DP21
5 6