Вы находитесь на странице: 1из 3

Software Release Notes

Phoenix System v1.6.1


This document describes the changes from the firmware v1.6.0 to v1.6.1.

Affected products
Christie Phoenix system

Purpose of v1.6.1 release


Added a change to the valid time range for the software certification to create the trust
relationship for the Phoenix Desktop Client.

Purpose of v1.6.0 release


Incorporated minor bug fixes and performance enhancements.
Added a global setting to enable changing the time zone and time for the controller and
all associated nodes. The default time zone setting is US Mountain Standard time.
Added support for MPEG-2.
Added a new setting on the Nodes page to disable/enable VNC access to a Phoenix node.
Added the node name to the node graphical representations in the Wall Profiles page.
Added a new feature to the Desktop Client that enables users to edit walls in an offline
mode. The changes are not updated on the wall until the user requests the
update.Enhanced security for the Desktop Client. After downloading this version of
software (1.6.0) as an administrator, when you attempt to sign in to a controller for the
first time you will be a prompted to create a trust relationship with the server. Click OK.

The Desktop Client will NOT connect until this relationship is established. After sending
the request (you will not receive a response from the request), sign in again.
Every time a different computer running the Desktop Client connects to a Phoenix
Controller for the first time, you will have to send a request to establish trust. This
includes controllers that you connected to with the previous software version.
Updated the JSON API to issue alerts and support compatibility with Christie Phoenix
Control Package for Crestron Control Systems.
Support was added for sources that are encoded by a Phoenix node with a resolution of
1400x1050.

Christie Phoenix System v1.6.1 Software Release Notes 1


020-101254-16 Rev. 1 (6-2017)
Copyright 2017 Christie Digital Systems USA Inc. All rights reserved.
Prerequisites
Controllers must be running v1.5.0 or v1.6.0 to update to v1.6.1.

Upgrade Instructions
Use the Update System feature in the Phoenix Web Manager to update the software.

Controllers must be running v1.5.0 or 1.6.0 to update to v1.6.1.

Updates to v1.5.0, v1.6.0, v1.6.1, or later versions require an operational commitment to applying
and retaining the security updates. The addition of the security features and trust certificates in these
versions makes rollback to prior firmware versions such as v1.4 a highly laborious task. If a
controller needs to be downgraded from 1.6.0 to an earlier software version, contact customer
support for assistance.
Prior to running the Desktop Client software, you must synchronize the time on the Phoenix system
with the PC that will run the Desktop Client. To do this, use the Time option in System Settings on
the Global Page in the Web Manager to set the time and time zone of the Phoenix Controller to the
same time and time zone as the PC that will run the Desktop Client. The time setting must be set
within a 5 minute range in order to run the Desktop Client.

Known Issues
The Run in System Tray option in the Startup Mode in the Desktop Client Settings must be
checked prior to running the Desktop Client. If it is not checked, issues may occur when
creating the trust relationship for the certificate.
Workaround: Navigate to the setting and check the Run in System Tray option. Exit the
Desktop Client software and restart it as an administrator.

Interlaced formats are not supported. Use progressive scan video formats with Phoenix and
Quad-T. Best practice with HD devices such as cameras, satellite, or cable receivers is to
configure the device to output 720p. Progressive scan video supplies superior image quality to
interlaced content, particularly material that includes motion.
For walls that are configured with the Enable Frame Synchronization option set to
BackChannel and repeatedly transitioning sources on the wall (manually or changing
layouts), the audio for a wall will sometimes crackle or stutter.
Workaround: To clear the problem, use the Desktop Client to reset the decoder network
streams. Right click on the source that is playing the audio for the wall and select Reset
Decoder Network Streams.

Christie Phoenix System v1.6.1 Software Release Notes 2


020-101254-16 Rev. 1 (6-2017)
Copyright 2017 Christie Digital Systems USA Inc. All rights reserved.
Administrators should not create any new users using admin as the user name. User accounts
created with this name will be invalid after a system restart. Additionally, note that the
username service is reserved for the default user name.
When an administrator uses the Force Logoff option, a popup is displayed to the users who
were logged off. The text in the dialog refers to a network connection and may be misleading.
The users should attempt to reconnect.
When spacing multiple sources, the spacing moves each source independently.
Workaround: None
When setting vertical spacing on more than two windows, the spacing for each window is
spaced independently.
Workaround: None
Direct Interaction is no longer automatically enabled.
Workaround: Contact customer support to enable it.
Some text strings for the Web Manager are not translated.
A 1-pixel green line may be visible on the bottom of Phoenix composited DVI and Application
sources. If the green line is visible, use the Crop, Pan, Zoom tool from the Desktop Client to
remove it or create a treatment that can be applied to layers to remove it.

Technical Support
North and South America: +1-800-221-8025 or Support.America@christiedigital.com

Europe, Middle East, and Africa: +44 (0) 1189 778111 or Support.EMEA@christiedigital.com

Asia Pacific: Support.APAC@christiedigital.com

Christie Phoenix System v1.6.1 Software Release Notes 3


020-101254-16 Rev. 1 (6-2017)
Copyright 2017 Christie Digital Systems USA Inc. All rights reserved.