Вы находитесь на странице: 1из 22

QCS 2014

Concrete Structures Requirements


Dr. Noureddin Issa Daas
NTCIS Chairman (National Technical Concrete Industry Subcommittee)
Consultant Construction Codes and Building Materials Specification
Qatar General Organization for Standardization

Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR


Concrete Structures Requirements

National Technical Committee for Preparing and Development


of QCS
National Technical Concrete Industry Subcommittee NT-CIS
Ministerial Decree
QCS 2014 Contents
Concrete Structures Design Requirements
Buildings environmental requirements
QCS Green requirements
Foundations and Retaining Structures
Aggregates
Concrete properties
Reinforcement

2 Grand Hyatt Doha Hotel 16th May 2017 , DOHA -


QCS 2014 QATAR
National Technical Committee for Preparing and
Development of QCS

3
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
National Technical Committee for Preparing and
Development of QCS

4
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
5
Ministerial Decree for approving QCS 2014 as a Technical
Regulation ( Compulsory Reg.)

6
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
QCS 2014 Contents
SECTION TITLE
Section 1 GENERAL :
QUALITY ASSURANCE AND QUALITY
Section 2
CONTROL
:

Section 3 GROUND INVESTIGATION :


FOUNDATIONS AND RETAINING
Section 4
STRUCTURES
:

Section 5 CONCRETE :
Section 6 ROADWORKS :
Section 7 GREEN CONSTRUCTIONS :
Section 8 DRAINAGE WORKS :
MECHANICAL AND ELECTRICAL
Section 9
EQUIPMENT
:
INSTRUMENTATION, CONTROL AND
Section 10
AUTOMATION
:

Section 11 HEALTH & SAFETY :


Section 12 EARTHWORKS RELATED TO BUILDINGS :
Section 13 MASONRY :
Section 14 ROOFING :
Section 15 INSULATION OF BUILDINGS :

7
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
QCS 2014 Contents
SECTION TITLE
Section 16 STRUCTURAL STEELWORKS :
Section 17 METALWORK :
CARPENTRY, JOINERY AND
Section 18
IRONMONGERY
:


Section 19 PLUMBING WORK :

Section 20 DRAINAGE WORKS FOR BUILDINGS :
Section 21 ELECTRICAL WORKS :
AIR CONDITIONING, REFRIGERATION AND
Section 22
VENTILATION
:

FIRE FIGHTING AND FIRE ALARM


Section 23
SYSTEMS
:

Section 24 FINISHES TO BUILDINGS :

Section 25 GLASS AND GLAZING :

Section 26 PAINTING AND DECORATING :

Section 27 EXTERNAL WORKS :


Section 28 LANDSCAPING :
Section 28 RAILWAYS :
8
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
Concrete Structures Design Requirements
Wind Speed
Wind speed shall not be less than the following based on the applied loads code/standard:
Nominal wind speed for 3 sec gust 38 m/s (A per ASCE 7-10 / IBC 2012)
Mean hourly wind speed 25 m/s (as per BS 6399-2)
Mean 10 minutes wind speed 27 m/s (as per BS EN 1991-1-4)

The seismic design for all building structure:


shall be based upon local seismic accelerations recommended as per
ASCE 7-10,
IBC 2012 or
BS EN 1998-1:2004.
Local seismic spectral accelerations based upon uniform hazard response spectra for 475 year and
2475 year return period for Doha as below.

9 Grand Hyatt Doha Hotel 16th May 2017 , DOHA -


QCS 2014 QATAR
Minimum Building Structure Design Working
Life
shall be minimum as specified below
Design Indicative Examples
working life design working
category life (years)
1 10 Temporary structures (a)

2 10 to 25 Replaceable structural parts, eg.


Gantry girders, bearings
3 15 to 30 Storage and similar structures
4 50 to 75 Building structures and other common
structures
5 120 Civil engineering structures like
bridges, tunnel etc.

10
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
Buildings Environmental Requirements

Thermal Insulation
For all new air conditioned buildings, the external walls, roofs
and floors exterior must have an average thermal transmittance
(U Value) which does not exceed the following values:
o Roof U= 0.44W/m2K
o External Wall U=0.57W/m2K
o Floor U=0.57W/m2K

Acoustical Control
o References were adopted

11
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
Buildings Environmental Requirements

Waste Management
Construction and Demolition Waste
For all new buildings unless or until specified otherwise, at least
fifty percent (50%) by volume or weight of Construction and
Demolition Waste of buildings must be recycled or reused.
Bulk Waste Collection
For all new residential apartment buildings, an area must be
provided for residents to place items of bulky waste such as
furniture and, electrical appliances
Recyclable Waste Management Facilities:
For all new buildings other than villas, a sorting and storage
facility for recyclable materials must be provided

12
QCS 2014 QNCC: 26-27 October 2014, Doha - Qatar
13
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
14
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
Foundations and Retaining Structures
Part1 General Requirements for Piling Work
Part2 General Requirements for Concrete Work
Part3 Shallow Foundations
Design considerations
Basis of Geotechnical Design
Geotechnical Design by Calculation
Part4 Deep Foundations
Part5 Retaining Structures
Ultimate and Serviceability Limit states
Actions and Geometrical Data
Design and Construction Considerations
Determination of Earth & Water Pressures
Ultimate and Serviceability Limit states Design

15
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
QCS 2014 - Section 5: Part 2: Aggregates

16
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
QCS 2014- Section 5: Part 6: Property Requirements
Concrete Structure Exposure Conditions:

Sulphate exposure classes S1 to S4: the exposure classes are related to sulphate
attack in relation to sulphate and pH of the ground water
17
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
QCS 2014- Section 5: Part 6: Property Requirements
SULPHATE EXPOSURE CLASSES:

18
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
Recommended durability requirement to resist
reinforcement corrosion
Cementitious
Exposure Class Minimum concrete cover (mm) type (Table
6.6)
No risk of
X0 25 All
corrosion
X1 Mild 45 40 35 30 All
X2 Moderate - 50 45 40 35 All
PC/FA
PC/GGBS
X3 Aggressive - 70 65 60 55
Triple
blend
PC/FA
PC/GGBS
X4 Severe* - 75 70 65 60
Triple
blend
Triple
X5 Extreme* - 80 75 70 65
blend
Minimum
C30 C40 C50 C60 C75
19concrete grade
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
Concrete Reinforcing Bars

Reinforcement shall be from an acceptable source. All steel


reinforcement bars shall comply with the requirements of:
QS ISO 6935 with minimum grade of B500 MPa or
BS 4449 with minimum grades of B500 MPa ; or.
ASTM A615 / A615M with minimum grade of 75 [520MpPa]; or
Deformed and Plain, Low-carbon, -Chromium, -Steel Bars for Concrete
Reinforcement: ASTM A1035/ A1035M -11
Other types of reinforcement, as approved by Qatar
As per project design, other steel grades of less than B500MPa
may be used only for stirrups and secondary reinforcement of
diameter of 10mm or less.

20
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
Concrete Structures Requirements

Future Concrete QCS 201?


Monitoring Structures?
Existing Buildings?

21
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR
Concrete Structures Requirements

Thank you

22
QCS 2014 Grand Hyatt Doha Hotel 16th May 2017 , DOHA - QATAR