Вы находитесь на странице: 1из 5

column calculation

column number grade of concrete M20 and HYSD 415


axial load
P= 15.63 KN
Ma(Hor.)= 0.9704 Mb(Ver.)= 0.363 KN.m
Length of column= 3.3 m effective length of column= 2.145 m
Column dim.= 0.25 0.25
b(m) d(m)
le/D= 8.58 < 12 short column (cl.-25.1.2) check

ea= 62.0857326 mm eb= 23.22457 mm check


Minimum eccentricities(Cl.-25.4)
ea min= 14.9333333 mm eb min.= 14.93333 mm
eccentricity classification:-
62.5 <ea,eb< 375 check
combined compression and bending-case3
Mpa(table
cbc= 7 21)
cc= 5 Mpa
m(modular ratio)= 13.33333333
Taking the minimum reinforcement(code value 0.8% Gross area)(Cl.26.5.3.1)
take reinforcement= 2 %
Asc= 1250 mm2
effective cover= 0.04 m
Ae= 77916.6667 mm2
Iea= 328758333 mm2 Ieb= 328758333 mm2
direct stress,c c'=P/Ae= 0.20059893 N/mm2
Bending stress due to Ma is (cbc)'a=(Ma*D/2Ia)= 0.36896403 N/mm2
Bending stress due to Mb is (cbc)'b=(Mb*D/2Ia)= 0.13801932 N/mm2
total bending stress= ((cbc)'a+(cbc)'b)= 0.506983 Mpa
design based on un cracked section:-
(cc'/cc)+(cbc'/cbc)= 0.112546 <=1

hence ok
3rd floor

column calculation
column number grade of concrete M20 and HYSD 415
axial load
P= 9.704 KN
Ma(Hor.)= 1.323 Mb(Ver.)= 0.2413 KN.m
Length of column= 3.3 m effective length of column= 2.145 m
Column dim.= 0.25 0.25
b(m) d(m)
le/D= 8.58 < 12 short column (cl.-25.1.2) check

ea= 136.335532 mm eb= 24.86603 mm check


Minimum eccentricities(Cl.-25.4)
ea min= 14.9333333 mm eb min.= 14.93333 mm
eccentricity classification:-
62.5 <ea,eb< 375 check
combined compression and bending-case3
Mpa(table
cbc= 7 21)
cc= 5 Mpa
m(modular ratio)= 13.33333333
Taking the minimum reinforcement(code value 0.8% Gross area)(Cl.26.5.3.1)
take reinforcement= 2 %
Asc= 1250 mm2
effective cover= 0.04 m
Ae= 77916.6667 mm2
Iea= 328758333 mm2 Ieb= 328758333 mm2

direct stress,cc'=P/Ae= 0.124543316 N/mm2
Bending stress due to Ma is (cbc)'a=(Ma*D/2Ia)= 0.50302907 N/mm2
Bending stress due to Mb is (cbc)'b=(Mb*D/2Ia)= 0.09174672 N/mm2
total bending stress= ((cbc)'a+(cbc)'b)= 0.594776 Mpa
design based on un cracked section:-
(cc'/cc)+(cbc'/cbc)= 0.109877 <=1

hence ok
2nd floor

column calculation
column number grade of concrete M20 and HYSD 415
axial load
P= 11.367 KN
Ma(Hor.)= 1.323 Mb(Ver.)= 0.2457 KN.m
Length of column= 3.3 m effective length of column= 2.145 m
Column dim.= 0.25 0.25
b(m) d(m)
le/D= 8.58 < 12 short column (cl.-25.1.2) check

ea= 116.389549 mm eb= 21.6152 mm check


Minimum eccentricities(Cl.-25.4)
ea min= 14.9333333 mm eb min.= 14.93333 mm
eccentricity classification:-
62.5 <ea,eb< 375 check
combined compression and bending-case3
Mpa(table
cbc= 7 21)
cc= 5 Mpa
m(modular ratio)= 13.33333333
Taking the minimum reinforcement(code value 0.8% Gross area)(Cl.26.5.3.1)
take reinforcement= 2 %
Asc= 1250 mm2
effective cover= 0.04 m
Ae= 77916.6667 mm2
Iea= 328758333 mm2 Ieb= 328758333 mm2
direct stress,c c'=P/Ae= 0.145886631 N/mm2
Bending stress due to Ma is (cbc)'a=(Ma*D/2Ia)= 0.50302907 N/mm2
Bending stress due to Mb is (cbc)'b=(Mb*D/2Ia)= 0.09341969 N/mm2
total bending stress= ((cbc)'a+(cbc)'b)= 0.596449 Mpa
design based on un cracked section:-
(cc'/cc)+(cbc'/cbc)= 0.114384 <=1
Ist floor

column calculation
column number grade of concrete M20 and HYSD 415
axial load
P= 2.324 KN
Ma(Hor.)= 0.4411 Mb(Ver.)= 0.2748 KN.m
Length of column= 3.3 m effective length of column= 2.145 m
Column dim.= 0.25 0.25
b(m) d(m)
le/D= 8.58 < 12 short column (cl.-25.1.2) check

ea= 189.802065 mm eb= 118.2444 mm check


Minimum eccentricities(Cl.-25.4)
ea min= 14.9333333 mm eb min.= 14.93333 mm
eccentricity classification:-
62.5 <ea,eb< 375 check
combined compression and bending-case3
Mpa(table
cbc= 7 21)
cc= 5 Mpa
m(modular ratio)= 13.33333333
Taking the minimum reinforcement(code value 0.8% Gross area)(Cl.26.5.3.1)
take reinforcement= 2 %
Asc= 1250 mm2
effective cover= 0.04 m
Ae= 77916.6667 mm2
Iea= 328758333 mm2 Ieb= 328758333 mm2

direct stress,cc'=P/Ae= 0.029826738 N/mm2
Bending stress due to Ma is (cbc)'a=(Ma*D/2Ia)= 0.16771438 N/mm2
Bending stress due to Mb is (cbc)'b=(Mb*D/2Ia)= 0.10448404 N/mm2
total bending stress= ((cbc)'a+(cbc)'b)= 0.272198 Mpa
design based on un cracked section:-
(cc'/cc)+(cbc'/cbc)= 0.044851 <=1

hence ok
Ist floor

column calculation
column number grade of concrete M20 and HYSD 415
axial load
P= 4.1828 KN
Ma(Hor.)= 0.8822 Mb(Ver.)= 0.1958 KN.m
Length of column= 3.3 m effective length of column= 2.145 m
Column dim.= 0.25 0.25
b(m) d(m)
le/D= 8.58 < 12 short column (cl.-25.1.2) check

ea= 210.911351 mm eb= 46.81075 mm check


Minimum eccentricities(Cl.-25.4)
eb
ea min= 14.9333333 mm min.= 14.93333 mm
eccentricity classification:-
62.5 <ea,eb< 375 check
combined compression and bending-case3
Mpa(table
cbc= 7 21)
cc= 5 Mpa
m(modular ratio)= 13.33333333
Taking the minimum reinforcement(code value 0.8% Gross area)(Cl.26.5.3.1)
take reinforcement= 2 %
Asc= 1250 mm2
effective cover= 0.04 m
Ae= 77916.6667 mm2
Iea= 328758333 mm2 Ieb= 328758333 mm2
direct stress,c c'=P/Ae= 0.053682995 N/mm2
Bending stress due to Ma is (cbc)'a=(Ma*D/2Ia)= 0.33542876 N/mm2
Bending stress due to Mb is (cbc)'b=(Mb*D/2Ia)= 0.07444678 N/mm2
total bending stress= ((cbc)'a+(cbc)'b)= 0.409876 Mpa
design based on un cracked section:-
(cc'/cc)+(cbc'/cbc)= 0.06929 <=1

Hence ok