Вы находитесь на странице: 1из 4

Latar belakang

Vibration survey 1
Spesifikasi alat

1 Digital Signature Analzer

Manufacturer CSI
Model 2120A-2
A/D converter 16bits of accuracy
Dynamic range Converter has 96dB range
Averaging mode normal, exponential, peak hold, order tracking, negative
Number of averages 5,000 in Route mode, 10,000 in Job mode
Resolution 1/3 Octave, 100, 200, 400, 800, 1600, 3200, 6400 lines
Frequency range DC to 10 Hz minimum
DC to 80 kHz maximum
Response flat to DC for non-integrated and DC-coupled signals
optional AC coupling -3 dB at 1 Hz
Frequency Units Hz, CPM, Orders
Full-scale range 3mV to 21V
Noise floor typically less than 0.5 V for a 400-line spectrum at 1000 Hz maximum
frequency
Windows Hanning or uniform
Integration None, Single, Double (Analog or Digital)
Automatic Integrator Correction feature allows precise measurement of low frequency vibrations
down to 0.2 Hz

1.1 Acceleration Transducer

Manufacturer CTC
Model 102A
Nominal Sensitivity 100 mV/g

1.2 Current Probe

Type Current Probe


Manufacturer Fluke
Model 80i-110S
Sensitivity 10 mV/A
Range 100 A
Nominal current 10 A, AC/DC
range 100 A, AC/DC
Continuous current 0.1 A - 10 A AC/DC

Vibration survey 2
range 1 A - 100 A AC/DC
Maximum non- 140 A - 2 kHz
destructive current
Lowest measurable 0.1 A
current
Basic accuracy 100 mV/A setting: 50 mA to 10 A 3% of reading +50 mA
10 mV/A setting: 50 mA to 40 A 4% of reading +50 mA
40 A to 80 A 12% of reading +50 mA
80 to 100 A 15% of reading
Useable frequency DC - 100 kHz
Output level(s) 10 A range: 100 mV/A
100 A range: 10 mV/A
Zero error adjustment Yes
Safety CAT II, 600 V
Type CAT III, 300 V

2 Thermal Imager

Manufacturer Fluke
Model Ti25
Temperature measurement range Converter has 96dB range
Field of view 23 x 17
Spatial resolution (IFOV) 2.5 mRad
Minimum focus distance Thermal lens: 15 cm (6 in)
Visible (visual) light lens: 46 cm (18 in)
Focus Manual
Image frequency 9 Hz refresh rate
Detector type 160 X 120 focal plane array, uncooled microbolometer
Infrared lens type 20 mm F = 0.8 lens
Thermal sensitivity (NETD) 0.09C at 30C target temp. (90 mK)
Infrared spectral band 7.5 m to 14 m
Visual camera 640 x 480 resolution

Vibration survey 3