Академический Документы
Профессиональный Документы
Культура Документы
00 m
PROYECTO: MEJORAMIENTO DE VIAS URBANAS EN LA LOCALIDAD DE HUABAL, DISTRITO DE HUABAL
- PROV DE JAEN - CAJAMARCA
DATOS:
FSD = 1.50 t1
FSV = 1.75
ANGULO FRIC. INTERNO = 23.17
COEF. EMP. ACTIVO Ka = 0.435
COEF. FRICCION DESL. f = 0.70
PESO DE RELLENO = 1.53 Ton/m3 Hp
PESO MURO CONCRETO = 2.40 Ton/m3
SOBRECARGA Ws/c = 0.10 Ton/m2
ALTURA EQUIV. S/C Ho = 0.065
ALTURA PANTALLA Hp = 2.00 m
t2
CAPACID. PORTANTE Gt = 1.10 Kg/cm2 Hz
CONCRETO f'c = 210 Kg/cm2
ACERO fy = 4200 Kg/cm2 B1 B2
t1 = 0.20 m
FUERZAS ACTUANTES
Ha = 2.188 Ton
Ma = 1.870 Ton-m
FSD = 1.692
FSD > 1.500 BIEN
FSV = 2.517
FSV > 1.750 BIEN
q1 = 0.649 Kg/cm2
q2 = 0.056 Kg/cm2
q1 < Gt BIEN!
q2 < Gt BIEN!
W = 1.20 Ton/m
Wu = 9.95 Ton/m
Mu = 1.2 Ton-m
d = 41.70 Cm (Recubrimento 7.5 cm. y 1/2 acero 5/8")
b = 100.00 Cm
DISEO DE MURO DE CONTENCION - H=2.00 m
PROYECTO: MEJORAMIENTO DE VIAS URBANAS EN LA LOCALIDAD DE HUABAL, DISTRITO DE HUABAL
- PROV DE JAEN - CAJAMARCA
F'c = 210 Kg/cm2
Fy = 4200 Kg/cm2
DISEO DE MURO DE CONTENCION - H=2.00 m
PROYECTO: MEJORAMIENTO DE VIAS URBANAS EN LA LOCALIDAD DE HUABAL, DISTRITO DE HUABAL
- PROV DE JAEN - CAJAMARCA
W = 0.004
As = 0.79 Cm2
Asmin= 0.0018*b*d
Asmin= = 7.51 Cm2 USAR ACERO 5/8" @ 27 Cm
qb = 3.72 Ton/m
q2 = 0.56 Ton/m
W = 4.36 Ton/m
Wu = 6.13 Ton/m B1-t2
M = 0.88 Ton/m
Mu = 1.2 Ton-m
d = 44.20 Cm
b = 100.00 Cm
F'c = 210 Kg/cm2
Fy = 4200 Kg/cm2
W= = 0.003
REFUERZO TRANSVERSAL
Ast= 9.00 Cm2 USAR: 5/8" @ 22 Cm
Armadura de montaje (3/8" o 1/2")
Asmontaje USAR: 3/8" @ 34 Cm
t1 0.20 m
2.00 m Hp
0.20 m
0.50 m t2
Hz
B1 B2
Hp
B1 B2
1.00 m 0.50 m