Академический Документы
Профессиональный Документы
Культура Документы
1) Release Note
Integrated Design System for Building and General Structures
Enhancements
Design 1
Pre/Post Processing 6
3 /16
Gen 2012 Design Enhancements Gen 2012 (v2.1) Release Note
(0 90)
4 /16
Gen 2012 Design Enhancements Gen 2012 (v2.1) Release Note
5 /16
Gen 2012 Design Enhancements Gen 2012 (v2.1) Release Note
Relevant clause of
TWN-SRC 92 TWN-SRC 100
TWN-SRC 100
4.3.5 Hoop of column
- Maximum hoop spacing for 100mm 150mm
rebar size D10
9.6.3 Design criteria for
column
Ar/Ag 4% Ar/Ag 3%
- Maximum reinforcement
ratio of main rebars
9.6.3 Design criteria for
column Min.(Hmin/4, 15cm) Min.(Hmin/4, 15cm, 6db)
- Maximum hoop spacing
H H
O O
U U
H H
O O
U U
6 /16
Gen 2012 Pre/Post Processing Enhancements Gen 2012 (v1.1) Release Note
EX
NTC 2008
7 / 16
Gen 2012 Pre/Post Processing Enhancements Gen 2012 (v1.1) Release Note
8 / 16
Gen 2012 Pre/Post Processing Enhancements Gen 2012 (v1.1) Release Note
9 / 16
Gen 2012 Pre/Post Processing Enhancements Gen 2012 (v1.1) Release Note
5. General Spring Support with 6x6 Coupled Matrix for Damping and Mass
General Spring Support with 6x6 coupled matrix for damping and mass to represent the
dynamic properties of Pile-Soil System has been added.
Related analysis functions are as follows:
Eigenvalue analysis
Response spectrum analysis
Linear time history analysis
Nonlinear time history analysis
Applicable analysis type for damping matrix are as follows:
Response spectrum analysis with Strain Energy Damping
Linear and nonlinear time history analysis (Analysis Method: Modal) with Strain
Energy Damping
Linear and nonlinear time history analysis (Analysis Method: Modal) with Strain
Energy Damping, Mass & Stiffness Proportional, Element Mass & Stiffness
Proportional
10 / 16
Gen 2012 Pre/Post Processing Enhancements Gen 2012 (v1.1) Release Note
Angle
Masonry Plastic Material
3D Masonry Structure
11 / 16
Gen 2012 Pre/Post Processing Enhancements Gen 2012 (v1.1) Release Note
7. Auto Generation of Wind Load for Chimneys, Tanks, and Similar Structure
Auto calculation of wind load for structural design of chimney, tank, and similar
structures
This option is provided for IBC(2000).
12 / 16
Gen 2012 Pre/Post Processing Enhancements Gen 2012 (v1.1) Release Note
Section Data
Material Data
13 / 16
Gen 2012 Pre/Post Processing Enhancements Gen 2012 (v1.1) Release Note
In the Story Shear Force Ratio table, results are displayed for Beam and Truss elements
separately. In the previous version, the results for beam and truss elements were
merged into Frame type.
It is useful when designing a building with dual frame system.
Results > Result Tables > Story > Story Shear Force Ratio
14 / 16
Gen 2012 Pre/Post Processing Enhancements Gen 2012 (v1.1) Release Note
15 / 16
Gen 2012 Pre/Post Processing Enhancements Gen 2012 (v1.1) Release Note
16 / 16