Академический Документы
Профессиональный Документы
Культура Документы
pH
ORP
ION
Conductivity
DO
Large Touch Screen
Large,
Easy-to-read display
Flat panel,
easy maintenance
New Line-up
Operated by
LCD Display Dry battery
Up to 2500 hours
1
Various Display Functions
Vertical/Horizontal
screen switch
YELLOWORP
Easy-to-move
WHITEConductivity
BLUEDO
Lead-free
RoHS compliant
DO electrode
2
Xseries Line-up
Touch Screen
Multi-function Water pH pH/Ion Meter pH Conductivity Meter Conductivity
Quality Meter
HM-42X CM-42X
0RP 0RP Resistivity
MM-43X
ION ION Salinity
Conductivity Including pH combined electrode Including conductivity cell Concentration
USB
sensors are sold Resistivity GST-5841C USB memory/ CT-58101B TDS
PC connectable
separately Salinity
External printer USB
Concentration USB memory/
Turntable PC connectable
TDS
2ch DO
External printer
Turntable
USB USP645
USB memory/
PC connectable
External printer
Turntable
USP645
External printer
Dry battery
For international
sales only
Accessories
MM-43X HM-42X CM-42X
Electrode attachmentb(J) 0IB00005 Strong pH composite electrode GST-5841C Electrical conductivity cell CT-58101B
Electrode attachment (DP) 0IB00007 Standerd solution pH 6.86 500mL 143F192 Poly beaker (150mL) 0DE00001
Electrode attachment (ION) 0IB00006 Standerd solution pH 4.01 500mL 143F191 AC adapter 7430880K
Poly beaker (150mL )3 0DE00001 Inner Solution for Reference Electrode 50mL 50mL Power cord 118C229
AC adapter 7430880K Poly beaker (150mL)3 0DE00001
Power cord 118C229 AC adapter 7430880K
Power cord 118C229
Common accessories for all the above model
Electrode holder 7430850KElectrode standw/column and stopper 7430860KElectrode attachment G2 sets for MM-43X 0IB00004
Tilt stand 7430870K Ground wire X0979500 Manual
Acccessories are included only when purchased in 1 set.
3
Accessories and Options
Product P/N Remarks Electrode
Holder
Electrode Holder 7430850K Electrode
Attachment
Electrode Stand 7430860K With support, stopper.
Connection Cable for Turntable 7433040K Cable length: 2m. For HM-42X, CM-42X, MM-43X.
For PC connection, 2m
For conncting to USB port, USB serial converter cable
RS-232C Connecting Cable 118N062
is necessary.
HM-42XCM-42XMM-43X
4
Electrodes
Cal-Memo sensor
pH/ORP The sensor memorizes Model, serial number, calibration data
Range Silver ion
Electrode Application Strong1 Float2
pHORP Temp. trap3
GST-5841C For general use pH014 0100
GST-5821C For general use pH014 0100
GST-5841S For organic solvent pH014 0100
GST-5842S For precise measurement pH014 060
GST-5823S For precise trace amount pH011 060
GST-5824C For insertion pH012 060
GST-5845C For trace amount pH013 0100
pH combined electrode
GST-5846C For extreme trace amount pH013 060
GST-5847C For test tube pH013 0100
GST-5848C For narrow test tube pH013 060
GST-5820C For flow-through type pH012 060
GST-5851C For high alkaline sample pH014 0100
ELP-040 For hydrofluoric acid bath pH212 050
5082L Glass electrode chip (For ELP-040)
Range of
ORP combined electrode PST-5821C For general use 0100
indication
ORP combined electrode Range of
PS-5011C For general use
Cal-Memo incompatible indication
Oxalate pH Standard Solution pH 1.68 500mL 143F194 ORP Standard Solution 143F196
Phthalate Standard Solution pH 4.01 500mL 143F191 Phthalate Standard Solution pH 4.01 500mLQuinhydrone powder)
Abrasive Solution for ORP Electrode 10mL AO-001
Phosphate pH6.86 Standard Solution 500mL 143F192
Borate Standard Solution pH 9.18 500mL 143F193 1 Strong Glass electrode. The strength of its tip is improved. Hard to break.
Carbonate pH Standard Solution pH 10.02 500mL 143F195 Float is built-in whose exchange span of internal solution
2 Float can be checked in a glimpse
Inner Solution for Reference Electrode RE-4 50mL3 0BG00011
Measurement performance of solution with shock absorbing
3 Silver Ion Trap characteristics such as tap water and alkaline solution is improved.
5
Conductivity
Range Cell
Cell Application
Conductivity Temp. Constant
CT-58101B For general use 100S/m10S/m1S/cm100mS/cm 0100 100m -1
Immersion type
CT-58101C For low electrical conductivity use 5S/m1S/m0.05S/cm10mS/cm 0100 10m -1
Conductivity cell
CT-58101A For high electrical conductivity use 1mS/m100S/m10S/cm1S/cm 0100 1000m -1
CT-88101B For general use 100S/m10S/m1S/cm100mS/cm 0100 100m -1
Flow-through type CT-88101C For low electrical conductivity use 5S/m1S/m0.05S/cm10mS/cm 0100 10m -1
Conductivity Cell CT-88102A For high electrical conductivity use 10mS/m100S/m100S/cm1S/cm 0100 2000m -1
CT-27111D For Pure Water 5S/m20mS/m0.05S/cm200S/cm 080 1m -1
Dissolved Oxygen
Measurement
Electrode Application Range Note
method
Membrane set OE-273AA3 sets) 0CC00001 Note1DO electrode cannot be used for the below membrane type
galvanic cell method.
Membrane Set OE-273AA High Range DO3 sets) 0CC00002
OE-270AA/570BA, 470AA/470BA
Membrane Set OE-573BA3 sets) 0CC00023
Membrane Set OE-573BA High Range DO3 sets) 0CC00024 Note2For BOD measurement, auxiliary equipment such as incubator
Membrane Set OE-473AA3 sets) 0CC00003 bottle and incubator is necessary.
Membrane Cartridge OE-473AA5 sets) CT-2502 Recommended incubator bottle
Membrane Set OE-473BA3 sets) 0CC00022 JIS standard Medium Size TS19/22Large-diameter
18.8mm, Reduced-diameter 16.6mm, Length 22mm
Electrolyte R-12 50mL3 sets) 143H008
Sodium Sulfite 50g 143A030
6
Ion
Electrode Ion replacement chip Measurement rangeOptimal pH range Intereference of coexisting ion 1/ Note
-
Fluoride ion combined electrode F-200 0.01919,000mg/L F OH =10
1
7
Specifications/Function
pH meter
Model Name HM-42X HM-41X HM-40X
pH Glass electrode method
pH Glass electrode method
Measurement ORP Platinum electrode method pH Glass electrode metho
ORP Platinum electrode method
Method Ion Ion electrode method TemperatureThermistor resistor
TemperatureThermistor resistor
Temperature Thermistor resistor
Display unit Touch panel color graphic LCD Customized LCD Customized LCD
pH pH0.00014.000 pH0.00014.000 pH0.00014.000
-500500 mV 1
VORP -2000.02000.0 mV -20002000 mV
Measurement ORP electrode not connectable
Item/Range Ion Depends on the sensor used
0.0100.0
Temperature 0.0100.0 0.0100.0
IonDepends on the electrode
pH pH-2.00016.000 pH-2.00016.000 pH-2.00016.000
VORP -2200.02200.0 mV -22002200 mV -550550 mV 1
ZoomOFF ZoomO
0.019.9g/L 0.0019.99g/L
20199g/L 20.0199.9g/L
Display Ion 0.201.99mg/L 0.2001.999mg/L
Range Manual/Auto 2.019.9mg/L 2.0019.99mg/L
Range Switching 20199mg/L 20.0199.9mg/L
mol/L selectable 0.201.99g/L 0.2001.999g/L
2.019.9g/L 2.0019.99g/L
20199g/L 20.0199.9g/L
2001990g/L 2001999g/L
Temperature -5.0110.0 -5.0110.0 -5.0110.0 1
pH 0.01pH/0.001pH 0.01pH/0.001pH 0.01pH/0.001pH
VORP 1/0.1mV 1mV 1mV
Display resolution 0.0g/L1990g/L
switch Maximum to 3-digits
Ion
0.00g/L1999g/L
Maximum to 4-digits
pH 0.002pH 0.006pH 0.006pH
Repeatability VORP 0.2mV 2mV 2mV 1
8
Conductivity meter
Model Name CM-42X CM-41X
Conductivity: AC 2-Electrode Method Conductivity: AC 2-Electrode Method
Measurement Method
Temperature: Thermistor Resistor Temperature: Thermistor Resistor
Conductivity Measuring frequency 80Hz/3kHz Auto-selection 80Hz/3kHz Auto-selection
Display unit Touch panel color graphic LCD Customized LCD
Conductivity Depends on the cell Depends on the cell
Resistivity Depends on the cell Depends on the cell
Measurement Salinity Conversion from conductivity Conversion from conductivity
Item/Range Concentration Conversion from conductivity
TDS Conversion from conductivity Conversion from conductivity
Temperature 0.0 100.0 0.0 100.0
0.0 200.0S/m 0.000 2.000S/cm 0.0 200.0S/m 0.000 2.000S/cm
0.000 2.000mS/m 0.00 20.00S/cm 0.000 2.000mS/m 0.00 20.00S/cm
Conductivity 0.00 20.00mS/m 0.0 200.0S/cm 0.00 20.00mS/m 0.0 200.0S/cm
Manual/Auto Range 0.0 200.0mS/m 0.000 2.000mS/cm 0.0 200.0mS/m 0.000 2.000mS/cm
Switching 0.000 2.000S/m 0.00 20.00mS/cm 0.000 2.000S/m 0.00 20.00mS/cm
Depending on the cell 0.00 20.00S/m 0.0 200.0mS/cm 0.00 20.00S/m 0.0 200.0mS/cm
0.0 200.0S/m 0.000 2.000S/cm 0.0 200.0S/m 0.000 2.000S/cm
SI unitS/morS/cmselectable SI unitS/morS/cmselectable
0.005 2.000 m0.5 200.0cm 0.005 2.000 m0.5 200.0cm
0.00 20.00 m0.000 2.000kcm 0.00 20.00 m0.000 2.000kcm
00.0 200.0 m0.00 20.00kcm 00.0 200.0 m0.00 20.00kcm
Resistivity
0.000 2.000km0.0 200.0kcm 0.000 2.000km0.0 200.0kcm
Manual/Auto Range
0.00 20.00km0.000 2.000Mcm 0.00 20.00km0.000 2.000Mcm
Switching
Display 00.0 200.0km0.00 20.00Mcm 00.0 200.0km0.00 20.00Mcm
Depending on the cell
Range 0.000 2.000Mm0.0 200.0Mcm 0.000 2.000Mm0.0 200.0Mcm
0.00 20.00Mm0 2000Mcm 0.00 20.00Mm0 2000Mcm
SI unit (S/m) and conventional unit (S/cm) selectable SI unit (m) and conventional unit (cm) selectable
0.00 4.04%NaCl 0.00 4.04%NaCl
Salinity
0.00 42.40psuPSS:Sea water salinity 0.00 42.40 (PSS:Sea water salinity)
Concentration 0 2.000%
Automatic Range 0 20.00%
Switching 0 200.0%
0 99.99mg/L 0 99.99mg/L
TDS 0 999.9mg/L 0 999.9mg/L
Manual/Auto Range 0 9.999g/L 0 9.999g/L
Switching 0 99.99g/L 0 99.99g/L
0 999.9g/L 0 999.9g/L
Temperature -5.0 110.0 -5.0 110.0
Conductivity 0.5% FS 0.5% FS
Resistivity 0.5% FS 0.5% FS
Repeatability Salinity 0.5% FS 0.5% FS
Meter main unit Concentration 0.5% FS
TDS 0.5% FS 0.5% FS
Temperature within 0.2 within 0.2
Temperature ATCAuto Temperature Compensation0 100.0 ATCAuto Temperature Compensation0 100.0
Compensation Range MTCManual Temperature Compensation0 100.0 MTCManual Temperature Compensation0 100.0
N/A ATCOFF ATCOFF
S t a n d a r d Te m p e r a t u r e
0 100.0 25 fixed
Setting
Temperature
Compensation Temperature Coefficient
0 10.00 0 10.00
Linear
Temperature Coefficient
2-10 points
Curve
Pure Water Dual
Temperature Compe.
Concentration Conversion Setting 2-10 points
Temperature Calibration 1-point Calibration 1-point Calibration
Performance Guaranteed Temperature, Humidity 0 4585 or belowcondensation-free 0 4585 or lesscondensation-free
Data Memory 2000 data 1000 data
Print Function Connectable to optional external printer EPS-P30 Connectable to optional external printer EPS-P30
Auto Hold Fuction
Auto Hold Conditions Setting
Statistical Calculation Function Average value
Calibration History Creation Function Max.20 run lots each Channel, 10 electrode Types Latest one run
Interval Measurement
Security Function
Upper/Lower Limit Output Setting
9
Multi-Function Water Quality Meter
Model MM-43X Model MM-43X
pH Glass Electrode Method ATCAuto Temperature Compensation
Temp.
ORP Platinum Electrode 0 100.0
pH compensation
Ion Ion Electrode Method MTCManual Temperature Compensation
range
Measurement Method Conductivity AC 2-Electrode Method 0 100.0
DO Membrane Polarographic ATCAuto Temperature Compensation
Method Temp.
0 100.0
Temperature Thermistor Resistor compensation
MTCManual Temperature Compensation
range
Conductivity Measuring 0 100.0
80Hz/3kHz automatic selection
Frequency N/A ATCOFF
2ch (pH/ORP/Ion/DO Electrode/ Standard
Electrode Inputs
Conductivity cell connectable) Temp. 0 100.0
Display Unit Touch Panel Color Graphic LCD Temperature setting
Selectable 2-ch Simultaneous Display or compensation Conductivity Temperature
Display
Single Only Display Coefficient 0 10.00
pH pH 0.000 14.000 Linear
VORP -2000.0 2000.0 mV Temperature
Coefficient 2 10 points
Ion Depends on the sensor
Multipoint
Conductivity Depends on the cell
Pure Water
Resistivity Conversion from conductivity Depend on the cell Dual Temperature
Salinity Conversion from conductivity Compensation
Measurement Concentration Conversion from conductivity Temperature
Item/Range Dissolved ATCAuto Temperature Compensation0
Compensation
TDS Conversion from conductivity Oxygen 50.0
Range
DO
Depends on the electrode JIS pH Standard Solution, US Standard
Saturation % Solution,
pH calibration
0.0 100.0 Custom Standard Solution, Max. 5-point
DO:0.0 50.0 Calibration
Temperature
Ion:Depends on the sensor (No temperature Ion calibration Max.5-point Calibration
measurement function)
DO calibration Auto CalibrationZero Span Calibration
pH pH-2.000 16.000
Temp. calibration 1-point Calibration
mVORP -2200.0 2200.0 mV
Conductivity Concentration
ZOOMOFF ZOOMO 2-10 points
Conversion Setting
0.0 19.9g/L 0.00 19.99g/L
DO Salinity Compensation
Ion 20 199g/L 20.0 199.9g/L
Setting
Manual/ 0.20 1.99mg/L 0.200 1.999mg/L
Auto range 2.0 19.9mg/L 2.00 19.99mg/L DO ATM Pressure
switching 20 199mg/L 20.0 199.9mg/L Compensation Setting
mol/L 0.20 1.99g/L 0.200 1.999g/L Performance Guaranteed
selectable 2.0 19.9g/L 2.00 19.99g/L 0 4585 or belowCondensation-free
Temperature, Humidity
20 199g/L 20.0 199.9g/L
Data Memory 2000 data each channel
200 1990g/L 200 1999g/L
Print Function Optional External Printer EPS-P30
0.0 200.0S/m 0.000 2.000S/cm
0.000 2.000mS/m 0.00 20.00S/cm Auto Hold Function
Conductivity 0.00 20.00mS/m 0.0 200.0S/cm Auto Hold Conditions
Manual/Auto 0.0 200.0mS/m 0.000 2.000mS/cm Setting
range switching0.000 2.000S/m 0.00 20.00mS/cm Statistical Calculation
Depends on the 0.00 20.00S/m 0.0 200.0mS/cm Average Value
Function
cell 0.0 200.0S/m 0.000 2.000S/cm
Calibration History Creation
SI unit (S/m) and Max. 20 run lots
Function
conventional unit (S/cm) selectable
Interval Measurement
0.005 2.000 m0.5 200.0cm
0.00 20.00 m0.000 2.000kcm Security Function
Display
Range 00.0 200.0 m0.00 20.00kcm Upper/Lower Limit Output
Resistivity 1ch only
0.000 2.000km0.0 200.0kcm Setting
Manual/Auto
0.00 20.00km0.000 2.000Mcm RS-232C
range switch 2ch
00.0 200.0km0.00 20.00Mcm Interface
Depends on the
0.000 2.000Mm0.0 200.0Mcm
cell USBHost
0.00 20.00Mm0 2000Mcm
SI unit (m) and USBPeripheral,
conventional unit (cm) selectable Micro
0.00 4.04%NaCl pH 700mVpH0 14
Salinity
0.00 42.40psu (PSS:Sea water salinity) mVORP 1V0 2000mV
Concentration 0 2.000% Ion 0 1VFS
Auto range 0 20.00% Conductivity/
switch 0 200.0% Resistivity/
0 99.99mg/L Salinity/ 0 1VFS
TDS 0 999.9mg/L External Concentration/
Manual/Auto 0 9.999g/L Input/ TDS
range switch 0 99.99g/L Output
DO/
0 999.9g/L Analog Saturation 0 1VFS
Dissolved 0.00 22.00mg/L Output
Range
Oxygen (High range membrane set (Option)0.00 55.0mg/L) (Ion/
0 220.0% Conductivity/
Saturation %
(High range membrane set (Option) 0 550%) Resistivity/ 100mV/Range
Temperature -5.0 110.0 Salinity/
Concentration/
pH 0.01pH/0.001pH
Display TDS)
mVORP 1mV/0.1mV
Resolution Temperature 0 1V0 100
Switching 0.0g/L 1990g/L (Maximum to 3 digits)
Ion Alarm Upper Limit Open Collector
0.00g/L 1999g/L (Maximum 4 digits)
(1ch only) Lower Limit Open Collector
pH 0.002pH
External Printer
mVORP 0.2mV
Turntable
Ion 0.5% FS
TTT510/710
Conductivity 0.5% FS Electrode Selector
Option
Resistivity 0.5% FS ES-1G
Connection
Repeatability Salinity 0.5% FS Cell Selector Single option can be connected to ch-1
Main body unit Concentration 0.5% FS ES-1GC
TDS 0.5% FS Control Box
For ch-1 only
AC-1V
Dissolved 0.03mg/L (Standard membrane)
Oxygen 0.1mg/L (High range membrane) Power Source AC100 240VAC Adapter
Saturation % 1% (Standard membrane/High range membrane) Power Consumption Approx. 18VA
Temperature within 0.2 Main Unit Dimensions
Excluding Protruding Approx. 130 W60 H230 D mm
Parts
Main Unit Weight Approx. 0.9kg
10
J-Series
pH Meter Practical manually operated analog and digital models
HM-7J pH Meter HM-20J pH Meter
Easy-to-read Easy-to-read of measurements
display with analog meter
pH3.510.5 Expansion scale: 200% digital display
Capable of measuring oxidation- Capable of measuring oxidation-
reduction potential (ORP) reduction potential (ORP)
(electrode sold separately) (electrode sold separately)
With mV-shift function With mV-shift function
Low price, compact size Low price, compact size
http://www.toadkk. co. jp/english Specifications and prices are subject to change without notice.
Issued on 20/6/2017