Boiler Specifications

INOV8 Boiler Model #s B175 B225 B275 B325 B400 B500 B650 B750 B850 B1050
Boiler with Burner Specifications
Boiler dimensions (h/w/l) in inches 24/23/47 24/23/51 24/23/56 24/23/61 41/35/60 41/35/66 41/35/80 41/35/87 41/35/93 52/38/93
Boiler dry weight 500 600 700 800 1,197 1,391 1,585 1,779 1,973 3,059
Water content - in gallons 16.1 19.3 22.5 25.6 37.8 45.2 52.6 60 67.4 78.7
Output BTUs (with INOV8 package) 140,000 180,000 220,000 260,000 320,000 400,000 520,000 600,000 680,000 840,000

Boiler & water side connections:


Water connection - in inches (NPT) 1 1/2 1 1/2 1 1/2 1 1/2 3 3 3 3 3 4
Return water connection (NPT) 1 1/2 1 1/2 1 1/2 1 1/2 3 3 3 3 3 4
Drain connection size - in inches 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
Flue connection in inches 6 up to 8 6 up to 8 6 up to 8 6 up to 8 7 up to 10 7 up to 10 7 up to 10 7 up to 10 7 up to 10 10 up to 12
Chimney height, minimum (no elbows) 15 15 15 15 15 15 15 15 15 15

Clearances (in inches)


Side wall 6 6 6 6 12 12 12 12 12 16
Side wall - burner door swing 16 16 16 16 43 43 43 43 43 43
Front (boiler length plus 40") 85 91 96 101 100 106 113 119 125 129
Behind boiler (1/2 boiler length plus 20) 43 45.5 48 50.5 50 53 56.5 59.5 62.5 64.5
Top of boiler 12 12 12 12 12 12 12 12 12 12
Chimney connector 18 18 18 18 18 18 18 18 18 18

Boiler operating requirements


Maximum operating temperature - F 240 240 240 240 240 240 240 240 240 240
Maximum operating pressure - PSIG 58 58 58 58 58 58 58 58 58 58
Maximum supply temperature - F 248 248 248 248 248 248 248 248 248 248
Minimum supply temperature - F 122 122 122 122 122 122 122 122 122 122
Minimum required draft - inches of WC -0.02 -0.02 -0.02 -0.02 -0.02 -0.02 -0.02 -0.02 -0.02 -0.02
Standard features of Buderus Boiler System:
Factory assembled cast iron sections (can be ordered knocked-down)
Jacket packaged separately in box
Full-size burner door hinged left or right (field adjustable)
Supply & return connections at rear of boiler
Blue enamel jacket with 3 1/2" wrap-around thermal insulation
Flexible GL-180M cast iron with silicon "barrier skin"
Precision casting eliminates need for manual grinding
No refractory or target cup needed due to chamber geometry
Precision machined steel push nipple sectional construction
Tongue and groove flue side sealing for pressurized operation
Boiler brush
Aquastat-recommend Honeywell model L8148A or L8151A (operational)
Boiler installation manual

Additional items needed for complete boiler installation:


Low-water cut-off (recommend Hydrolevel Company Safgard - PN#45-175 with probe #EL1214-SV)
Circulators, mixing valves, zone controls & tubing/piping for water side

Burner Only Specifications


Burner model # R200 R200 R200 R200 R200 R200 R200 R700 R700 R700
Input BTU 175,000 225,000 275,000 325,000 400,000 500,000 650,000 750,000 850,000 1,050,000
Nozzle size #30609 - 3.1 3.1 3.1 5 5 5 8 8 8 11
Oil pressure setting * 9 11 14 5 7 10 10 12 13 9
GPH 1.25 1.6 1.96 2.32 2.85 3.5 4.6 5.35 6.07 7.5
Burner dimensions (height/width/length) 14/18/16 14/18/16 14/18/16 14/18/16 14/18/16 14/18/16 19/24/25 19/24/25 19/24/25 19/24/25
Compressed air requirements: CFM 2 2 2 3 3 3 4 4 4 5
Compressed air requirements: PSI 30 30 30 30 30 38 38 38 38 38
Air regulator, single or dual Single Single Single Single Single Single Dual Dual Dual Dual
Dual air regulator operating pressure - - - - - - 70 70 70 70
Secondary air band settings 2 2 2 to 3 2 to 3 2 to 3
Air connection to regulator 1/4" NPT 1/4" NPT 1/4" NPT 1/4" NPT 1/4" NPT 1/4" NPT 1/4" NPT 1/4" NPT 1/4" NPT 1/4" NPT
Electrical requirements (in amps) 20 20 20 20 20 20 20 30 30 30
Volts / Hertz 120/60 120/60 120/60 120/60 120/60 120/60 120/60 120/60 120/60 120/60
Burner Motor - hp 1/5 1/5 1/5 1/5 1/5 1/5 1/3 1/3 1/3 1/3
Fuel Pump connection (3/4" or larger) 1/4 NPT 1/4 NPT 1/4 NPT 1/4 NPT 1/4 NPT 1/4 NPT 1/4 NPT 1/4 NPT 1/4 NPT 1/4 NPT
Weight - in pounds 52 52 52 52 52 52 80 80 80 80

Shipped with Burner


Boiler Door Modifications
Spare fuses - one 4 amp, one 7 amp, one 10 amp
Instruction Manual for burner
Stainless inserts for boiler
Spare filter for vapor eliminator
Maintenance schedule & log
Tjernlund Draft Inducer, model D-3 D-3 I I
Exhausto Blower System, blower size: 160 160 160 160 160 180
Exhausto connection size 6 6 6 6 6 8
Exhausto pressure settings ** 0.1 0.1 0.1 0.1 0.1 0.1
Regulator Assembly
Shipping weight - in pounds (of above) 100 100 100 100 120 120 120 130 130 140
Floating Oil Pickup / Filter Assembly, includes filter mount with bypass filter, floating oil pickup, 2" fitting for tank & checkvalve
** Optional boost pump, includes filter mount with non-bypass filter, & oil strainer & excludes floating oil pickup

On-site items required for burner (not supplied by INOV8)


Oil line from tank
Return line to tank
Compressed Air supply line
Chimney
Oil storage tank (minimum size)
Electrical supply