Академический Документы
Профессиональный Документы
Культура Документы
2
Hyde Marine, Inc. 2013 2
COMPANY INTRODUCTION
3
Hyde Marine, Inc. 2013 3
Calgon Carbon Corporation
Global manufacturer and supplier of activated carbon and innovative purification systems
for drinking water, wastewater, and a variety of industrial and commercial manufacturing
processes.
4
Hyde Marine, Inc. 2013 4
Hyde MarineA company of firsts
Subsidiary of Calgon Carbon Corp.
Long history as marine equipment supplier since 1865
Experience in BWTS since 1996 one of first BWTS installed
One of first to get USCG AMS Approval (April 2013)
First technology accepted into USCG STEP in 2008
One of 1st IMO Type Approved BWTS (April 2009) by MCA (UK Flag)
Global Agent Network in over 42 countries
AMS Approval
6 GUADIAN Systems for Royal
First BWTS M/S Regal Princess Navy CVF Aircraft Carriers GUARDIAN Gold
Hyde Windlass Co. Bath Maine
USCG STEP Approval Coral IMO TA & Launch
First Hyde GUARDIAN M/S CCC acquisition
Hyde Marine & Univ. Princess
Coral Princess
Michigan BW Study
1865 1969 1996 1998 2000 2002 2004 2006 2008 2010 2012 2014
5
Hyde Marine, Inc. 2013 5
Hyde Marine: Approved & Proven
Multiple Class Type Approvals
Produced under ISO 9001: 2008
Quality System
Received orders for over 300 Hyde
GUARDIAN BWTS for more than
247 vessels (>140 installed)
Over 130 vessels in service
Tested
Test >50 micron 10 to 50 micron <10 micron Passed
6
Hyde Marine, Inc. 2013 6
REGULATIONS
7
Hyde Marine, Inc. 2013 7
Existing & Pending Regulations
Entered into force December 1, 2013
U.S. Coast Applies to all commercial ships discharging ballast in U.S. waters
Guard BWTS must have AMS approval or full USCG approval
Applies to all vessels keel laid after 1 Dec 2013, Retrofits starting 1 Jan 2014
# Vessels
Not all BWTS suitable for each 6,000
application
HM has significant installation & 4,000
operation experience on
2,000
newbuilds AND retrofits
9
Hyde Marine, Inc. 2013 9
THE SOLUTION:
BALLAST WATER TREATMENT
10
10
Hyde Marine, Inc. 2013 10
Treatment Solutions
Typically a two stage process:
2. Disinfection
To kill or inactivate remaining organisms:
Chemical (AOP, electro-chlorination, chlorine, ozone, peracetic
acid, etc.)
Requires additional Basic and Final Approval
according to G9
Physical ( UV, deoxygenation, cavitation, ultrasound, etc.)
11
11
Hyde Marine, Inc. 2013 11
Chemical Disinfection
Types
Chlorination
Electro-chlorination/Electrolysis
AOP (TiO2, hydrogen peroxide, or ozone)
Ozone
Benefits
Effective disinfection/oxidation agent
Certain benefits for high flow systems
Ozone - Relatively easy installation for tanker retrofit (no equipment in pump room)
Disadvantages
Safety & cost of carrying chemicals on board
Creation of explosive hydrogen gas with electrolysis
Does not treat chlorine resistant organisms
Ineffective in low salinity and low temperature water (Electro-chlorination)
Potential ballast tank corrosion
Must neutralize discharge with chemical agents (another chemical to carry)
Ozone - Safety of hazardous ozone in shipboard environment
12
12
Hyde Marine, Inc. 2013 12
UV Disinfection
Description
Mercury-vapor lamps encased in quartz sleeves generate light in the
germicidal range of the electromagnetic spectrum
UV light in this region damages nucleic acids in DNA of
microorganisms preventing replication and thereby inactivating the
organisms
No residual disinfectant
Benefits
Kills / inactivates living organisms
Does not create toxic compounds or utilize free radicals
environmentally neutral
Eliminates handling and storage of toxic chemicals
No tank corrosion
Disadvantages
Frequent cleaning of lamp sleeves in the presence of iron and
suspended solids
Electrical consumption in high capacity systems
13
13
Hyde Marine, Inc. 2013 13
14
14
Hyde Marine, Inc. 2013 14
Hyde GUARDIAN Gold BWTS
A two-stage treatment process
Fine mesh screen filter mechanical stage
Medium pressure UV disinfection stage
Modulates dose based on measured UV
intensity and flow
Designed to seamlessly integrate with ship
Very low maintenance and upkeep for crews
15
15
Hyde Marine, Inc. 2013 15
Hyde GUARDIAN Gold BWTS
During Ballasting During Deballast
OUTLET TO
OUTLET
TANKS
OVERBOARD
INLET INLET
BACKFLUSH
FROM FROM
OVERBOARD
SEA TANKS
16
16
Hyde Marine, Inc. 2013 16
FILTRATION
17
17
Hyde Marine, Inc. 2013 17
Hyde GUARDIAN Gold BWTS
Filtration
Two screen filters used to optimize effectiveness
Uses Filtrex from HG60G HG700G
Smallest footprint
Non-ferrous material and simple operation
Finest filtration mesh for sediment removal
Uses Hydac from HG1000G HG6000G
Sources inlet pressure for backflush efficiency
Robust, highly engineered filter designed for ballast water
Exceptional volumetric efficiency for high-flow applications
18
18
Hyde Marine, Inc. 2013 18
Filtrex ACB Filter
Nickel-Aluminum-Bronze (Ni-Al-Bz)
filter body
Canister-type filter with a central
indexing arm and pleated filter
element
Increases filter surface area
Maintains smallest footprint
Canister is Ni-Al-Bz housing with
316L stainless steel mesh
19
19
Hyde Marine, Inc. 2013 19
Filtrex: Main Advantages
Smallest footprint
Very few parts
less spares
easy to maintain
Quick backwash
ideal for challenging
conditions
No contact between
the rotating shaft and
the filtering element.
20
20
Hyde Marine, Inc. 2013 20
Hydac RF10 Filter
21
21
Hyde Marine, Inc. 2013 21
Reliance on Inlet, Not Outlet
Pressure
As screen fouls,
Traditional screen filters pressure at filter
use differential pressure outlet lowers creating
between outlet and drain less differential
to drive backwash between outlet and
drain line
reducing backwash
pressure.
22
22
Hyde Marine, Inc. 2013 22
UV DISINFECTION
23
23
Hyde Marine, Inc. 2013 23
UV Characteristics
Inactivates organisms & prevents replication eventually leading to death
Relative Output
0.70
0.60
wavelength (254nm) required for drinking 0.50
0.40
water (giardia and cryptosporidium) 0.30
0.20
Medium Pressure UV
Emits over broad spectrum to target wide variety of organisms found in BW 200nm
320nm
10 - 15% conversion of power to germicidal UV light
Operating temperature of 600 to 800C
24
24
Hyde Marine, Inc. 2013 24
UV Cost Considerations
5-year cost of ownership for 250m3/hr system
Low Pressure Medium Pressure
# Lamps 23 6
25
25
Hyde Marine, Inc. 2013 25
New Product Innovations
Local/remote selector switch
on the control panel Relocation UV cooling valve to top
of UV reactor chamber for improved
air removal
26
26
Hyde Marine, Inc. 2013 26
New Product Innovations
Improved touch screen Operator Interface
Terminal (OIT) and upgraded PLC controller
with increased speed and memory capacity One touch, external
access and download
capability of the data
log via USB drive
27
27
Hyde Marine, Inc. 2013 27
SELECTING HYDE MARINE
28
28
Hyde Marine, Inc. 2013 28
Hyde GUARDIAN Gold BWTS
Compact - smallest footprint of any UV system
Robust Easy to use & install requires minimal specialized training/little operator
attention or maintenance
Design Operates with virtually no pressure drop
Scalable UV dose for optimized sizing from 60 m3/hr to 1488 m3/hr per unit
29
29
Hyde Marine, Inc. 2013 29
Hyde Marine Experience
Over 300 units in 247 vessels
Offshore (101) Cruise (22) Naval (9) RORO/Ferry (5)
Tanker (21) Bulk Carrier (2) LPG/LNG (4) Gen Cargo (15)
30
30
Hyde Marine, Inc. 2013 30
Hyde Marine Customers
31
31
Hyde Marine, Inc. 2013 31
Trust in Hyde Marine
Proven Experience in marine industry and UV disinfection
IMO Type Approval
Longest history with manufacturing, installation, & operation of BWTS:
1st to install BWTS on a vessel (10+ years reliable operation)
First USCG STEP approved system (long term relationship with USCG)
130+ installed
Most systems in operation
Understand issues and considerations in BWT
Reliability & Reputation
On time delivery
Can operate in various salinities/water temperatures
Long term support
Factory trained global service network (includes
companies used by major shipping companies)
Spare parts availability
Investment in growth with strong corporate support
32
32
Hyde Marine, Inc. 2013 32
LEAVE NOTHING BUT YOUR WAKE
Headquarters
Agents
33
33
Hyde Marine, Inc. 2013 33