phasec D62

Unrivalled Inspection Power in a


Portable Package
Inspection of heat exchanger bundles
Weld inspection on metal structures such as bridges, cranes
Reliable detection of surface and subsurface cracks in metal
Two independent channels with independent alarms
Dual frequency/dual probe operation
NiCad or Alkaline battery operation up to 8 hours
Portable, lightweight (5.1kg/11.2lbs) and rugged
Integral Universal power adapter (90 to 264 VAC)

H
Specifications it works where you work...
Operating Frequency Regular inspection of bridges, oil rigs and power plants are an essential component of safety
Single frequency mode: 60Hz-6MHz and plant life extension programs. The D62 provides eddy current functionality to cover a vast
Dual frequency mode: 100Hz-2MHz
(Max Ratio of channel 1 to channel 2 is 10:1)
range of metal inspection applications, from simple crack detection to multi layer corrosion
detection - as well as conductivity measurement, coating thickness measurement and dynamic
Display inspection. The unit operates with probes and coils from all quality manufacturers in both
Electroluminescent screen with selectable
persistence of 0.1 to 20 seconds or standard and special applications - for further details of the Hocking probe range request a
permanent. copy of the probe catalogue or consult our website www.hocking.com.
Channels
Dual channel, dual frequency, dual
probe capabilities
Smart Signal Representation
Gain A broad range of frequency and filter
Overall adjustment 0 to 90dB in 0.1dB
steps. Gain ratio of X:Y -20dB to + 20dB options allow the application to be set up
in 0.1dB steps. exactly as required. The AutoMix facility
Mix Function allows unwanted signals such as support
The mix result (Ch2 subtracted from Ch1) plates to be rapidly mixed out leaving
can be displayed. Phase is fully just the flaw signal required.
adjustable. Gain adjustment as X:Y ratio
above.
Digital Record/Replay
Low and High Pass Filters The D62 allows the operator to record
Low Pass : 3Hz to 2kHz in 15 steps
High Pass : DC to 2kHz in 70 steps
an inspection, and then adjust param-
eters such as phase, filters, gain and
Alarms alarm gates whilst the trace is played
Two independent alarms available.
Sector, Box Gate, and timebase. back and modified in real time.
Flashing LEDs, internal sounder, and
open collector outputs. Typical Applications Connectivity
The D62 is a versatile unit that can be used in a The D62 has extensive options for con-
Internal Data Storage wide range of industry. For Weld Inspection on
Capacity for up to 50 traces and 50 nection including RS232 and remote
settings. 14 character alphanumeric file metal structures such as oil rigs, bridges and control. 6 BNCs and 2 D-types on the
descriptions. Records up to 32 seconds cranes the unit can be used with the WeldScan rear panel can provide a variety of
of data for playback.
range of probes. This provides a comprehensive outputs defined by the user.
Inputs/Outputs and rapid inspection without the need to remove
Six analogue outputs chosen from
Channel 1, Channel 2 and mix. RS232,
coatings. Flexible power supply options
two alarm outputs. Inputs for on/off, If battery operation is required then the
clear and balance.
In Power Plants tasks such as the inspection of non
ferrous heat exchanger bundles can be simplified D62 can run for a full days inspection
Conductivity Measurement and speeded up by the D62. The advanced two on either NiCad or standard Alkaline
Measures the conductivity of non-ferrous
channel design allows a simultaneous absolute/ cells. If AC connection is required then
metals in the range
1% to 110% IACS (0.58 to 63.8 MSm-1 ). differential inspection, so any gradual changes in the D62 has an integral universal AC
Reqs. conductivity probe 47P001/ lead 33A135/ adapter that allows instant connection.
calibration standard 47A023
material can be identified at the same time - such
as localised cracking, pitting and corrosion. Accessories
Coating Thickness
Measurement Once the applications have been set up and The D62 can be operated with a wide
Measures thickness of non-conducting optimised they can easily be stored in the unit range of third party software packages
coatings in the range for recall later and printed for report writing or including tube sheet representation and
0 to 1.25mm (0 to 0.05 inches).
Requires accessories as above. reference. signal analysis. In addition other probes
and accessories are available.
Weight Total alarm flexibility
5.1kg (11.2lb) including batteries.
The operator has full control of the Advanced
Dimensions alarm functions allow the precise setup of gates
255 W x 105 H x 310 L mm.
(10 x 4.1 x 12.2 inches). for your application. Alarms can be configured
to trigger on on-screen displays and even non-
Power displaying datastreams. The choice of alarm
Integral AC Adapter/charger -
90 to 264 VAC, 47 to 440Hz. types includes Box, Sector, and Timebase.
H
Hocking NDT Ltd., Inspec House, 129-135 Camp Road, St Albans,
Hertfordshire, UK, AL1 5HL
Tel: +44 (0)1727 795500 Fax: +44 (0)1727 795400
For more information visit www.hocking.com email: info@hocking.com web site: www.hocking.com
In a continuing effort to improve the quality of our products, technical
and environmental information in this document is subject to change
without notice.. D62sys_01.p65. June 1999