Вы находитесь на странице: 1из 33

RBS 6000

DANIEL MANTOVAN
RBS 6000 portfolio

Multi-standard RBS
Legacy evolution path
Integrated simplicity
Integrated simplicity with
common building practice
RBS 6101
RBS 6601
RBS 6000 RBS 6201

RBS 6301

Evolved Modules

RRU

RBS 6102
High capacity & integrated RBS
143.5cm

Radio Units
GSM/WCDMA/LTE

Transmission
Module

Site Power

Cooling

RBS 6201 RBS 6101 RBS 6102


High capacity concentrated in one cabinet
Macro site solution (capacity valid for Indoor/Outdoor)

GSM 3x4 900


GSM 3x4 1800
WCDMA 3x2 2100 (30W)
WCDMA 3x2 850 (30W)

IP
Microwave / fiber optic transmission

Secure site power


Battery Backup

RBS 6201
Digital Unit for GSM (DUG)
Prepared for the future
Supports multistandard
Main Unit

Capacity
Up to 12 TRX
Half the size of predecessor
Multiple digital units (TG-sync)
Digital Unit for WCDMA (DUW)
Baseband

ATM & IP

Main Unit

Multiple Digital Units

Three variants DUW 30 DUW 20 DUW 10 Hardware prepared for HSPA+


MIMO and 64QAM downlink
768 DL 384 DL 128 DL
Channel Elements 16QAM uplink
512 UL 384 UL 128 UL
Multi-carrier
DL Peak
252 126 42 Continuous packet connectivity
Throughput (Mbps)
Multistandard ready
UL Peak
Throughput (Mbps)
48 36 12
Digital Unit for LTE (DUL)
Prepared for high peak rates
2x2 MIMO
64QAM DL & UL

Prepared for the future


Supports for LTE System Architecture Evolution
Supports for multiple digital units & redundancy
Multistandard ready

IP transmission capability
All IP architecture with full non-blocking connectivity
100/1000BASE-T
SFP slot for 1000BASE-X
Multistandard Radio Unit (RUS)
Multistandard support
GSM, WCDMA and LTE
HW supports for two technologies
simultaneously
Extremely compact
Output Power @ ARP
60W on all bands (4x20W on GSM*)
Output power and carrier flexibility
HW activation licenses
4 carriers
20MHz IBW
EDGE Evolution ready
HSPA Evolution ready
Remote Radio Unit: RRUW 01

Technical Specifications
Radio specification
Output power: Up to 60 W nominal
Carriers: Up to 4

Size & Weight


Volume: 23 litres w/o sun shield
Weight: 20 kg
Dimension: 600 x 350 x 112 mm

Power
Input voltage: -48 V DC or AC

Other
Convectional cooling, no fan
Support for ASC/TMA, Direct RET interface
2 external alarm ports
RRU cascading
Operating temperature range (-33 C to +55 C)
MTBF targeting 50 year
* Assumptions:
Room temp, Constant Nominal output power
Rbs 6102 and 6201 dimensions
RBS 6102 Main HW units
RBS 6201 Main HW units -48vcc
RBS 6201 Main HW units +24vcc and AC
Rbs 6102 and 6201 configuration examples
GSM

wcdma
Digital unit tx interfaces
RBS 6601 19 Main Remote solution
19 building practise, 1,5U Height
Fits indoor or outdoor site cabinets
Based on RBS 6000 modules
1-12 RRU to the Main Unit
Multistandard

Dimensions 483x350x66 mm WxDxH

Weight (Fully equipped 9 Kg


cabinet)
Temperature range +5C to +50C
Digital Unit 6601 Configuration Examples
WCDMA 3x4

GSM 3x4 + LTE 3x20 MHz

WCDMA 3x2 + GSM 3x4 /


LTE 3x20 Mhz
Hardware units in Main unit 6601
Connection interfaces
a) Earth grounding interface
B) Built-in external alarm interface
c) Support alarm unit (optional)
d) Power interface
E) Site lan interface - DU
e) Gps interface - DU
e) Optical cable interface - DU
e) Tx, ethernet electrical - DU (WCDMA,LTE)
e) Tx, ethernet optical - DU (WCDMA,LTE)
e) tx, 4 e1 wcdma and gsm - DU
Synchronization of 2 DUWs
Rbs 6601 configurations - RRUW
Configuration Number of Radio Units Output Power per Cell Carrier (W)

31 3 RRUW 01 20 / 40 / 60

31 MIMO 6 RRUW 01 20+20 / 40+40 / 60+60

32 3 RRUW 01 10 / 20 / 30
32 6 RRUW 01 20 / 40 / 60

32 MIMO 6 RRUW 01 10+10 / 20+20 / 30+30

3x2 MIMO 3 RRUW 11 5+5/10+10/15+15

33 3 RRUW 01 20

33 MIMO 6 RRUW 01 20+20


34 3 RRUW 01 15

34 6 RRUW 01 20 / 30

34 MIMO 6 RRUW 01 15+15

61 6 RRUW 01 20 / 40 / 60

62 6 RRUW 01 10 / 20 / 30
Rbs 6601 configurations - DUW

Configuration DUW 30 2*DUW 30

Cell carriers 6 12
Channel Elements,
768/512 1536/1024
(Downlink/Uplink)
DL Peak Throughput (Mbps) 252 504

UL Peak Throughput (Mbps) 48 96