Project/ Aplication : Case study Software Calculator of Tot Head, Pipe Dia.

& Cavitation (Metode : Hazen William)


Consultant/ Contractor : Training By : Ir. MA. Budiman, Hp. 087770678615, mochalibudiman@gmail.com, R12.09.13
Dated : 20/02/2017 12:57 Reference : Australian Pump manufacturer Association (APMA Limited 1982, Reprinted 1993)
AL1
Discharge/Outlet pipe : PIPE-1 PIPE-2 PIPE-3
% Flow rate (Q) % : 100% 0% 0%
Flow rate (Q) m3/jam : 200,0 0,0 0,0
Input data, only to white box
Ld (pipe lenght 1,2,3) mtr : 1000,0 0,0 0,0
20/02/2017 12:57 Vapour press = 0,43 mtr I--------- Ld3 -------------------------I
o
C

IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
28/01/3014 Water temp = 30 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Ld total : 1000,0

------------- Ld2-------------------------
I--------------------------------------
55,6
PIPE SUCTION Flow rate (Q) = 200,0 m3/hr Hd, Discharge Headmtr : 10,0
Pls select Piping Configuration 1
No.1: Negatif suction /w positif discharge Hg.. Geodetic head mtr : 20,0
Pls select mat'l suction pipe 3 Tot .Head = 49,3 mtr Pls select Nominal dia. : 200 mm 0 mm 0 mm
Galvanized Iron C : 129 NPSHr = 4 mtr Pls select material pipe : Galvanized Iron - -
Lenght of suction pipe, Ls mtr : 8,0 Eff. Pump = 81 % 3 0 0
Pls select Nom dia. suction pipe 12 P2, Power = 33,19 kW Hanzen William Constanta : 129 0 0
200 mm 200,0 12 0 0
Inner dia. suction pipe mm : 200,0 pipe level I I---- Ld1-------------- 200 200 200

I--------------------- Ls -----------
Input manual inner dia? (Y/T) : T gound level Pump-1 Inner diameter mm : 200,0 0,0 0,0

I---------Hs--------
________________________

______________________________
IIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
If Y, Input inner dia. pipe mm : 0 Input inner dia?(Y/T) : T T T
Velocity (Ideal 0.9-2 m/s) m/s : 1,77 NO CAVITATION If Y, Input inner dia mm : 0,0 0,0 0,0
Velocity (Ok = Ideal) : Ok Velocity Ideal 0.9-2, m/sec : 1,77 0,00 0,00
Pipe Diameter (Ok = Ideal) : Ok Velocity (Ok = Ideal) : Ok - -
Suction lift (Hs) mtr : 2,0 Dia. of pipe (Ok = Ideal) : Ok - -
Vertical distance from pipe level to water level ~~~ ~~~ SF Pipe + Fitting % : 0%
No. ball valve pcs : 0 ~~~ ~~~~~
No. butterfly valve pcs : 1 ~~~ ~~~~ No. ball valve pcs : 0 0 0
No. swing chek valve pcs : 0 ~~~ ~~~~ No. butterfly valve pcs : 1 0 0
No. elbow (90o), (45o) pcs : 1 ~~ ~FV Foot Valve No. check valve pcs : 1 0 0
No. Tee pcs : 0 ~~~~~~~~~ No. elbow90o, 45o pcs : 2 0 0
No. foot valve, / mtr : 0,9 pcs : 1 No. Tee pcs : 0 0 0
Pressure Drop-1 mtr : 0,0 Pressure Drop-1 mtr : 0,0 0,0 0,0
Pressure Drop-2 mtr : 0,0 Pressure Drop-2 mtr : 0,0 0,0 0,0
Pressure Drop-3 mtr : 0,0 0,0 0,0
NPSHa 6,05 mtr
NPSHr 4,00 mtr
NPSHa > NPSHr Flow rate (Q) 200,0 m3/hr
NO CAVITATION Tot. head (H) 49,4 meter

-Suction Lift, Hs < .... 4,05 mtr Input, Pump Type


Input, NPSHr 4,0 meter
Input, Pump Eff. 81,0 %
MA. Budiman, 081290493938
P2, pump power 33,2 kW