Вы находитесь на странице: 1из 17

HYDRAULIC CARTRIDGES

COUNTERBALANCE VALVES

16.04 39
HYDRAULIC CARTRIDGES
COUNTERBALANCE VALVES

INTRODUCTION

Counterbalance valves are hydraulic valves designed specifically to hold and control negative or
gravitational loads. They are meant to serve all those applications that involve the control of suspended
loads, such as mechanical joints, lifting applications, extensible movable bridge, winches, etc
Counterbalance valves main functionalities are lowering velocity control and stationary load holding.
Counterbalance valves hydraulic symbol is similar to an integrated micro-circuit, in which 3 characteristic
components can be identified:

(A1,1) (A, 2)

(X, 3)

A uni-directional valve, which allow a free feeding to the hydraulic actuator and lock load in the
required position.
A pressure relief valve, which, thanks to its specific configuration, holds the loads acting on hydraulic
actuators (for instance, cylinders or motors) and limits max pressurization, allowing also stress
control, where needed.
A pilot piston, which opens the pressure relief valve, thanks to connection to hydraulic energy source.

A1 B1

A B
B1
A1
B

A1 A

A1 B1

A B

Fig.2 Example of counterbalance valve application

Generally, counterbalance valves are installed directly on cylinders or hydraulic actuators (ex. Port A1-1).

40 16.04
HYDRAULIC CARTRIDGES
COUNTERBALANCE VALVES

That guarantees load control and holding even in case of rupture or external leakage of the hoses
connecting valve and setting device (directional control valve). Picture nr. 2 shows an example of truck
crane hydraulic scheme, which is a typical application for counterbalance valves.

WORKING PRINCIPLE

Thanks to the uni-directional valves, oil flow regulated by the directional control valve comes inside the
cylinder facing minimum resistance.
When directional spools are in neutral position, sealing devices are in rest position, locking connection
between hydraulic actuator and directional control valve. Thanks to mechanical sealing obtained
through grinded sealing point, its possible to avoid leakage through the spools of uni-directional valve.
Counterbalance valves, in fact, are able to close with very small leakage (<10 drops/min). Since there are
no dents nor saturation effects (possible even in case of clean oil), a perfect sealing will take place in a
few minutes.
Pump Connection to pilot line (X-3) consequence of directional spool change-over determines the
progressive opening of the counterbalance valves, up to the balance satisfying the flows continuity
equation. That guarantees the absence of cavitations and also the control of dragged loads lowering
velocity.

SETTING

Counterbalance valves setting corresponds to the opening pressure of pressure relief section. This
pressure determines the max load which counterbalance valve is able to hold.
Usually the setting pressure value must be at least 1.3 times the max load induced pressure to hold. That
tolerance allows induced loads safe holding.

1 2

3
4 lpm

Fig.3

Standard setting pressure (Pt) of counterbalance valves corresponds to pressure on port (1), while the
valve is crossed by a 4l/min flow (picture 3).

es. Pt: 350 bar @ 4 l/min

In particular cases, and generally upon customers request, the pressure can be set considering the initial
opening value, corresponding almost to 20 ml/min. flow.

es. Pt: 350 bar @ 20 ml/min

16.04 41
HYDRAULIC CARTRIDGES
COUNTERBALANCE VALVES

PILOT RATIO

As mentioned before, counterbalance valves are characterized by a pilot area on which pressure coming
from the actuators feeding line acts. Such pressure, together with the pressure due to the load, moves
pilot piston, progressively contrasting the force generated by the setting spring.
Hence the combined action of the two pressures is connected to the ratio between the pushing areas on
which they act. This ratio is known as Pilot Ratio (pr), and it is the basic parameter for any counterbalance
valve.
Pilot Ratio (pr) is defined as the geometrical ratio between the area on which the load acts (port 1) and
the pilot area (port 3). Thanks to this parameter, it is possible to calculate the values of pilot pressures
first opening (Px):
(A1)1

Po (Setting)
P1 (Load)
Px = (Pt P1) / rp PX*rp (Pilot)
(X)3

(A)2

According the Pilot Ratio, counterbalance valves can be divided in 2 types:


High Pilot Ratio (>6:1): suitable for those applications where the loads are constant (for instance,
hydraulic motors) and very stable, where low pilot pressures are demanded in favour of speed and energy
savings.
Low Pilot Ratio (<5:1): suitable for those applications where loads can vary (for instance, trucks cranes)
and for those mechanical structures are not stable, where more control and more stability are needed, an
higher pilot pressure is required.
When counterbalance valves are installed on hydraulic actuators, to determine the correct value of pilot
pressure it is necessary to introduce in the calculation the ratio between the areas of the actuator itself.

Px = (Pt P1) / (rp+ra)


ra: ratio between the areas of the hydraulic actuator

ra= cap area/annular area ra = 1

ra = area fondello / area anulare

(A1)1 (A1)1 (A1)1

(X)3 (X)3 (X)3

(A)2 (A)2 (A)2

42 16.04
HYDRAULIC CARTRIDGES
COUNTERBALANCE VALVES

COMPENSATION

Because of coupling counterbalance valves with directional control valves, considering the type of spool to
use is needed. When the counterbalance valves are in charge of the pressure relief function, its essential
to make a distinction between closed-centre spool applications and open-centre spool application.
Generally, when closed-centre spools are installed, its necessary to use compensated counterbalance
valves: since these valves are insensitive to back-pressure on return line (A-2), their pressure setting
wont change.

1 2 1 2 1 2

3 3 3

Two examples of compensated valves application are regenerative circuits and circuits in which draining
of eventual pressure peaks must be relieved in series by the anti-shock valves installed inside the
directional control valve.
In case of open-centre directional spool application, not-compensated valves are compulsory, in which
the spring is connected to the return line (A-2).

In Not-Compensated (N) type valves, back-pressure affects both pressure setting and pilot pressure
In these valves, the return line is directly connected to the spring. Valves in which adjustable spring is
connected to return line are not compensated ones.
Main use: open-centre spool application.

In Fully-Compensated (C) type valves, back-pressure does not affect neither pressure setting nor pilot
pressure. Belong to this type the valves in which the adjustable spring is separated from return line (A-2)
and is connected to a draining line or is air-vented.
In these valves, back-pressure (A-2) is balanced, so it wont find any area to carry out its force, so that
both setting and pilot pressures are independent from pressure on return line (A).
Main use: closed-centre spool applications, regenerative circuits.

In Relief-Compensated (S) valves, only pressure setting is independent from back-pressure, while pilot
pressure is affected by back-pressures, which sometimes can be helpful in stabilizing the circuit.
To this kind of valves belong all the valves in which only the area subject to the load (A1-1) is balanced.
Main use: closed-centre spool applications.

16.04 43
0612.0
Cartridge SAE 08
NOT compensated counterbalance valve

Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 l/min


Max working pressure. . . . . . . . . . . . . . . . . . . . 350 bar
Compensation. . . . . . . . . . . . . . . . . . Not compensated
Cartridge tightening torque. . . . . . . . . . . . . . . . 40-45 Nm
Seal lock nut tightening torque. . . . . . . . . . . . . 15-20 Nm 1 2
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,2 Kg
Tamper proof cap . . . . . . . . . . . . . . . .cod. 4029250280
To be ordered separately only for version 0-prearranged
Cavity . . . . . . .. . . . . . . . . . . . . . C321000 page 219
Body single cavity. . . . . . . . . . . . . 172212 page 188
Body double cavity . . . . . . . . . . . . 176212 page 189
3

Hex. 5 30

25
Hex.17

Pressure [bar]
1
20
2
2
15
1
54 max

69,6

10

5
109,6

Hex.24 0
0 5 10 15 20 25 30 35 40
Flow [l/min]

23,8
5

Note
3/4-16 UNF-2A
-Setting: 1,3 times the maximum load induced pressure.
3 15,8 -The back pressure (2) may affect the relief function
(for circuits with back pressure use 0612.1 or 0612.2).
40

1
14,2

Ordering code

06120 00

PILOT RATIO SPRINGS 2 3 TAMPER PROOF OPTION


5 5:1
Setting range PRE-ARRANGED 0
120 - 210 170 - 350
[bar]

Pressure Increase
NOT PRE-ARRANGED 2
35 60
[bar/turn]
Standard setting
4 l/min [bar] 210 350

44 16.04
0612.2
Cartridge SAE 08
RELIEF compensated counterbalance valve

Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 l/min


Max working pressure. . . . . . . . . . . . . . . . . . . . 350 bar
Compensation. . . . . . . . . . . . . . . Relief compensated
Cartridge tightening torque. . . . . . . . . . . . . . . . 40-45 Nm
Seal lock nut tightening torque. . . . . . . . . . . . . 15-20 Nm 1 2
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,2 Kg
Tamper proof cap . . . . . . . . . . . . . . . .cod. 4029250280
To be ordered separately only for version 0-prearranged
Cavity. . . . . . . . . . . . . . . . . . . . C321000 page 219
Body single cavity. . . . . . . . . . . . 172212 page 188 3
Body double cavity . . . . . . . . . . . 176212 page 189

Hex. 5 30

25
Hex.17

Pressure [bar]
1
20
2
2
15
1
54 max

69,6

10

5
109,6

Hex.24 0
0 5 10 15 20 25 30 35 40

Flow [l/min]

23,8
5

Note
3/4-16 UNF-2A
-Setting: 1,3 times the maximum load induced pressure.
3 15,8
40

1
14,2

Ordering code

06122 00

PILOT RATIO SPRINGS 2 3 TAMPER PROOF OPTION


5 5:1
Setting range PRE-ARRANGED 0
120 - 210 170 - 350
[bar]

Pressure Increase NOT PRE-ARRANGED 2


35 60
[bar/turn]
Standard setting
4 l/min [bar] 210 350

16.04 45
0612.1
Cartridge SAE 08
fully compensated counterbalance valve

Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 l/min


Max working pressure. . . . . . . . . . . . . . . . . . 350 bar
Compensation. . . . . . . . . . . . . . . .Fully compensated
Cartridge tightening torque. . . . . . . . . . . . . . 40-45 Nm
Seal lock nut tightening torque. . . . . . . . . . . 15-20 Nm 1 2
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,2 Kg
Tamper proof cap. . . . . . . . . . . . . . .cod. 4029250280
To be ordered separately only for version 0-prearranged
Cavity . . . . . . . . . . . . . . . . . . . C321000 page 219
Body single cavity. . . . . . . . . . . . 172212 page 188
Body double cavity . . . . . . . . . . . 176212 page 189
3

Hex.5
30

25

Pressure [bar]
1
Hex.17 20
2
2
54 max

69,6

15
1
VENT 10

5
109,6

Hex.24
0
0 5 10 15 20 25 30 35 40
Flow [l/min]
23,8
5

3/4-16 UNF-2A
Note
3 15,8 -Setting: 1,3 times the maximum load induced pressure.

-To be used only with A/B closed center spools.


2
40

1
14,2

Ordering code

06121 00

PILOT RATIO SPRINGS 2 3 TAMPER PROOF OPTION


5 5:1
Setting range PRE-ARRANGED 0
120 - 210 170 - 350
[bar]

Pressure Increase NOT PRE-ARRANGED 2


35 60
[bar/turn]
Standard setting
4 l/min [bar] 210 350

46 16.04
0613.0
Cartridge SAE 10
NOT compensated counterbalance valve

Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70 l/min


Max working pressure. . . . . . . . . . . . . . . . . . . 350 bar
Compensation. . . . . . . . . . . . . . . . Not compensated
Cartridge tightening torque. . . . . . . . . . . . . . . 50-55 Nm
Seal lock nut tightening torque. . . . . . . . . . . . 15-20 Nm 1 2
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,3 Kg
Tamper proof cap . . . . . . . . . . . . . . . .cod. 4029250280
To be ordered separately only for version 0-predisposed
Cavity . . . . . . . . . . . . . . . . . . . C331000 page 221
Body single cavity. . . . . . . . . . . . 172312 page 193
Body double cavity . . . . . . . . . . . 176312 page 194
3

Hex.5 35

30
Hex.17

Pressure [bar]
25
1
20
2
55 max

70,5

2
15
1
Hex.24 10

0
118,5

0 10 20 30 40 50 60 70
Flow [l/min]
26,8
4,5

7/8-14 UNF-2A Note


-Setting: 1,3 times the maximum load induced pressure.
3 19
-The back pressure (2) may affect the relief function
(for circuits with back pressure use 0613.1 or 0613.2).
48

1
17,4

Ordering code

06130 00

PILOT RATIO SPRINGS 2 3 TAMPER PROOF OPTION


3 3,5:1
Setting range PRE-ARRANGED 0
8 8:1 80 - 210 180 - 350
[bar]

Pressure Increase NOT PRE-ARRANGED 2


37 47
[bar/turn]
Standard setting
4 l/min [bar] 210 350

16.04 47
0613.2
Cartridge SAE 10
RELIEF compensated counterbalance valve

Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70 l/min


Max working pressure. . . . . . . . . . . . . . . . . . . 350 bar
Compensation. . . . . . . . . . . . . . Relief compensated
Cartridge tightening torque. . . . . . . . . . . . . . . 50-55 Nm
Seal lock nut tightening torque. . . . . . . . . . . . 15-20 Nm 1 2
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,3 Kg
Tamper proof cap . . . . . . . . . . . . . . . .cod. 4029250280
To be ordered separately only for version 0-prearranged
Cavity . . . . . . . . . . . . . . . . . . . C331000 page 221
Body single cavity. . . . . . . . . . . . 172312 page 193 3
Body double cavity . . . . . . . . . . . 176312 page 194

Hex.5 35

30
Hex.17

Pressure [bar]
25
1
20
2
55 max

70,5

2
15
1
Hex.24 10

0
118,5

0 10 20 30 40 50 60 70
Flow [l/min]
26,8
4,5

7/8-14 UNF-2A Note:


-Setting: 1,3 times the maximum load induced pressure.
3 19
48

1
17,4

Ordering code

06132 00

PILOT RATIO SPRINGS 2 3 TAMPER PROOF OPTION

3 3,5:1
Setting range PRE-ARRANGED 0
80 - 210 180 - 350
[bar]

Pressure Increase
NOT PRE-ARRANGED 2
37 47
[bar/turn]
Standard setting
4 l/min [bar] 210 350

48 16.04
0613.1
Cartridge SAE 10
fully compensated counterbalance valve

Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70 l/min


Max working pressure. . . . . . . . . . . . . . . . . . . 350 bar
Compensation. . . . . . . . . . . . . . . . Fully compensated
Cartridge tightening torque. . . . . . . . . . . . . . . 50-55 Nm
Seal lock nut tightening torque. . . . . . . . . . . . 15-20 Nm 1 2
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,3 Kg
Tamper proof cap . . . . . . . . . . . . . . . .cod. 4029250280
To be ordered separately only for version 0-predisposed
Cavity . . . . . . . . . . . . . . . . . . . C331000 page 221
Body single cavity. . . . . . . . . . . . 172312 page 193
Body double cavity . . . . . . . . . . . 176312 page 194
3

Hex.5 35

30

Pressure [bar]
25
1
20
VENT 2
2
70,5

15
55 max

Hex.24 1
10

5
118,5

0
0 10 20 30 40 50 60 70
Flow [l/min]
4,5

26,8

7/8-14 UNF-2A Note:


-Setting: 1,3 times the maximum load induced pressure.
19
-To be used only with A/B closed center spools.
48

17,4

Ordering code

06131 00

PILOT RATIO SPRINGS 2 3 TAMPER PROOF OPTION


3 3,5:1
Setting range PRE-ARRANGED 0
80 - 210 180 - 350
[bar]

Pressure Increase NOT PRE-ARRANGED 2


37 47
[bar/turn]
Standard setting
4 l/min [bar] 210 350

16.04 49
0614.0
Cartridge SAE 12
NOT compensated counterbalance valve

Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 l/min


Max working pressure. . . . . . . . . . . . . . . . . . . . 410 bar
Compensation. . . . . . . . . . . . . . . . Not compensated
Cartridge tightening torque. . . . . . . . . . . . . . . . . 60 Nm
Seal lock nut tightening torque. . . . . . . . . . . .15-20 Nm 1 2
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,7 Kg
Tamper proof cap . . . . . . . . . . . . . . . cod. 4029250280
Cavity. . . . . . . . . . . . . . . . . . . . C341000 page 223
Body single cavity. . . . . . . . . . . . 172412 page 199
Body double cavity . . . . . . . . . . . 176412 page 200 3

Hex.5
35

30
Hex.17
25

Pressure [bar]
2 1
20
2
1
15
79,6
67,3 max

10
Hex.32
137,5

0
36 0 20 40 60 80 100 120
Flow [l/min]
5

11/16-12 UN-2A Note:


-Setting: 1,3 times the maximum load induced pressure.
3
23,72 -The back pressure (2) may affect the relief function
57,9

(for circuits with back pressure use 0614.2 or 0.614.1).


2

22,15

Ordering code

06140 000

PILOT RATIO SPRINGS 4


5 5:1
Setting range
230 - 410
[bar]

Pressure Increase
34
[bar/turn]
Standard setting
4 l/min [bar] 350

50 16.04
0614.2
Cartridge SAE 12
RELIEF compensated counterbalance valve

Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 l/min


Max working pressure. . . . . . . . . . . . . . . . . . . 410 bar
Compensation. . . . . . . . . . . . . Relief compensated
Cartridge tightening torque. . . . . . . . . . . . . . . . . 60 Nm
Seal lock nut tightening torque. . . . . . . . . . . .15-20 Nm 1 2
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,7 Kg
Tamper proof cap . . . . . . . . . . . . . . . cod. 4029250280
Cavity. . . . . . . . . . . . . . . . . . . . C341000 page 223
Body single cavity. . . . . . . . . . . . 172412 page 199
Body double cavity . . . . . . . . . . . 176412 page 200
3

Hex.5
35

30
Hex.17
25

Pressure [bar]
2 1
20
2
1
15
79,6
67,3 max

10
Hex.32
137,5

0
0 20 40 60 80 100 120
36
Flow [l/min]
5

11/16-12 UN-2A Note:


-Setting: 1,3 times the maximum load induced pressure.
3 23,72
57,9

1
22,15

Ordering code

06142 000

PILOT RATIO SPRINGS 4


5 5:1
Setting range
230 - 410
[bar]

Pressure Increase
34
[bar/turn]
Standard setting
4 l/min [bar] 350

16.04 51
0614.1
Cartridge SAE 12
fully compensated counterbalance valve

Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 l/min


Max working pressure. . . . . . . . . . . . . . . . . . . . 410 bar
Compensation. . . . . . . . . . . . . . . Fully compensated
Cartridge tightening torque. . . . . . . . . . . . . . . . . 60 Nm
Seal lock nut tightening torque. . . . . . . . . . . .15-20 Nm 1 2
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,7 Kg
Tamper proof cap . . . . . . . . . . . . . . . cod. 4029250280
Cavity. . . . . . . . . . . . . . . . . . . . C341000 page 223
Body single cavity. . . . . . . . . . . . 172412 page 199
Body double cavity . . . . . . . . . . . 176412 page 200
3

Hex.5
35

30
Hex.17
25

Pressure [bar]
2 1
20
2
1
15
79,6
67,3 max

10
Hex.32
137,5

5
VENT
0
0 20 40 60 80 100 120
36 Flow [l/min]
5

Note:
11/16-12 UN-2A
-Setting: 1,3 times the maximum load induced pressure.

3 -To be used only with A/B closed center spools.


23,72
57,9

22,15

Ordering code

06141 000

PILOT RATIO SPRINGS 4


5 5:1
Setting range
230 - 410
[bar]

Pressure Increase
34
[bar/turn]
Standard setting
4 l/min [bar] 350

52 16.04
0644.0
Cartridge M27x1,5
NOT compensated counterbalance valve

Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 l/min


Max working pressure. . . . . . . . . . . . . . . . . . . . 410 bar
Compensation. . . . . . . . . . . . . . . . Not compensated
Cartridge tightening torque. . . . . . . . . . . . . . . . . .60 Nm
Seal lock nut tightening torque. . . . . . . . . . . . 15-20 Nm 1 2
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,7 Kg
Tamper proof cap . . . . . . . . . . . . . . . .cod. 4029250280
Cavity . . . . . . . . . . . . . . . . . . . . . . M340000 page 234

Hex.5
35

30

Hex.17 25

Pressure [bar]
2 1
20
2
1
15
67,3 max

79,4

10

Hex.32
133,6

0
0 20 40 60 80 100 120
36
Flow [l/min]
5

Note:
M 27x1.5 -Setting: 1,3 times the maximum load induced pressure.
3 -The back pressure (2) may affect the relief function
54

24,5 (for circuits with back pressure use 0.6441 o 0.6442).

1
23

Ordering code

06440 000

PILOT RATIO SPRINGS 4


5 5:1
Setting range
230 - 410
[bar]

Pressure Increase
34
[bar/turn]
Standard setting
4 l/min [bar] 350

16.04 53
0644.2
Cartridge M27x1,5
RELIEF compensated counterbalance valve

Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 l/min


Max working pressure. . . . . . . . . . . . . . . . . . . . 410 bar
Compensation. . . . . . . . . . . . . Relief compensated
Cartridge tightening torque. . . . . . . . . . . . . . . . . .60 Nm
Seal lock nut tightening torque. . . . . . . . . . . . 15-20 Nm 1 2
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,7 Kg
Tamper proof cap . . . . . . . . . . . . . . . .cod. 4029250280
Cavity . . . . . . . . . . . . . . . . . . . . . . M340000 page 234

Hex.5
35

30

Hex.17 25

Pressure [bar]
2 1
20
2
1
15
67,3 max

79,4

10

Hex.32
133,6

0
0 20 40 60 80 100 120
36
Flow [l/min]
5

Note:
M27x1.5 -Setting: 1,3 times the maximum load induced pressure.
3
54

24,5

1
23

Ordering code

06442 000

PILOT RATIO SPRINGS 4


5 5:1
Setting range
230 - 410
[bar]

Pressure Increase
34
[bar/turn]
Standard setting
4 l/min [bar] 350

54 16.04
0644.1
Cartridge M27X1,5
fully compensated counterbalance valve

Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 l/min


Max working pressure. . . . . . . . . . . . . . . . . . . . 410 bar
Compensation. . . . . . . . . . . . . . . . Fully compensated
Cartridge tightening torque. . . . . . . . . . . . . . . . . .60 Nm
Seal lock nut tightening torque. . . . . . . . . . . . 15-20 Nm 1 2
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,7 Kg
Tamper proof cap . . . . . . . . . . . . . . . .cod. 4029250280
Cavity . . . . . . . . . . . . . . . . . . . . . . M340000 page 234

Hex.5
CH5
35

30
Hex.17
CH17
25

Pressure [bar]
2 1
20
2
1
15
67,3 max

79

10
Hex.32
CH32
133,6

5
VENT
0
0 20 40 60 80 100 120
36 Flow [l/min]
5

Note:
M27x1,5
-Setting: 1,3 times the maximum load induced pressure.

3 -To be used only with A/B closed center spools.


24,5
54

23

Ordering code

06441 000

PILOT RATIO SPRINGS 4


5 5:1
Setting range
230 - 410
[bar]

Pressure Increase
34
[bar/turn]
Standard setting
4 l/min [bar] 350

16.04 55

Вам также может понравиться