Вы находитесь на странице: 1из 1

POTENCIA CORRIENTE BREAKER

PDD CIRCUITO # PUNTOS POTENCIA TOTAL VOLTAJE # POLOS CONDUCTOS DUCTO DESCRIPCIN
WATTS A B F/SEG. F/SIM. A.AP AMP.
WATTS
A1 10 60 600 120 5.00 1.25 0.75 4.69 15.00 1 14 PVC 1/2 FOCO
T1 925 120 7.71 1.25 0.75 7.23 15.00 1 12 PVC 1/2 SALA, COMEDOR, BAO
T2 1 2250 2250 220 10.23 1.25 0.75 9.59 15.00 2 12 PVC 1/2 ACONDICIONADOR DE AIRE
PDPB
T3 2245 120 18.71 1.25 0.75 17.54 30.00 1 10 PVC 1/2 COCINA
T4 3000 120 25.00 1.25 0.75 23.44 30.00 1 10 PVC 1/2 LAVANDERIA
SUBTOTAL 33.94 32.71
A1 8 60 480 120 4.00 1.25 0.75 3.75 15.00 1 14 PVC 1/2 FOCO
T1 1250 120 10.42 1.25 0.75 9.77 15.00 1 12 PVC 1/2 DORM P, SALA COMUN
PDPA T2 1 2250 2250 220 10.23 1.25 0.75 9.59 15.00 2 12 PVC 1/2 ACONDICIONADOR DE AIRE
825 120 6.88 1.25 0.75 6.45 15.00 1 12 PVC 1/2 DORM 1. DORM3
SUBTOTAL 14.42 17.10
TOTAL 48.35 49.81