c:ktfngl;{ xf]dz}lIfs ;+:yf :s"n, sn]hljBfnodxfljBfnoljZj
ljBfnotflnd s]Gb|sf]gofF ejg lgdf{0fgljs/0f:yfg kl/jt{g:t/f]GgtL
Pj+ pkof]u kl/jt{g sf] k|of]hgsf] nflu
>L zx/L ljsf; tyf ejg lgdf{0f ljefu
l8lehg sfof{no sf7df8f}+, aa/dxn .
/fli6o ejg ;++lxtf sfof{Gjogsfo{ljlw, @)^) n] Aoa:yf u/]sf] cfwf/df lgDg
:yfgdfc:ktfngl;{ xf]dz}lIfs ;+:yf :s"n, sn]hljBfnodxfljBfnoljZj
ljBfnotflnd s]Gb| sf] gofF ejg lgdf{0fgljs/0f:yfg kl/jt{g:t/f]GgtL Pj+
pkof]u kl/jt{gsf] k|of]hgsf] nflu tkl;n adf]lhdsf] gS;f tyf sfuhft ;+nUg u/L gofF
lgdf{0f eP l8hfOg;xdlt / k'/fgf] ejgdf ;+rfng eO/x]sf] eP ejgsf] agfj6 ;DaGwdf
Seismic Vulnerability Evaluation /Assessmentu/L l;kmfl/; kfpg lgj]bg u/]sf 5f} .

ejg :yn M
======================lhNnf===============g=kfuf=lj=;j8fg++==
=======GfS;f g++=============lsQf g+============
;+:yfkssf] gfd M
7]ufgf M
kmf]g g+= M
;+:yfkssf]] tkm{af6 b:tvt ug]{sf] gfd M ;+:yfkssf] sfof{nosf] 5fk
b:tvtM
kb M
ldlt M
/fli6o ejg ;++lxtf sfof{Gjogsfof{ljlw, @)^) cg';f/ l8hfO{g k|of]hgsf] lgDt
k|of]u ul/Psf] ejg ;+lxtfsf] lsl;d s'g xf] ;f]df /]hf lrGx nufpg'xf];\ .

s_ O{G6/g]zgn :6]6 ckm cf6{ (International State of Art)


v_ k|f]km];gnL OlGhlgo8{ lalN8 (Professionally Engineered
Buildings)
u_ DofG8]6/L ?N; ckm yDa (Mandatory Rules of Thumb)
3_ u|fld0f If]qsf nflu ejg lgb]{lzsf (Guidelines for Remote Rural
Buildings Low Strength Masonry / Earthen Buildings)

;+nUg sfuhftx? M
!_ cfls{6]Sr/n gS;fx? M Laboratory Block (3-LAB-6-ERMC)
S. No. Drawings No.of Sheets
1 Floor plans. AR-01,AR-
02AR-03,AR-04
2 Elevations. AR-05
3 Two sections Longitudinal Section and Cross section (One of the AR-06
sections should be through staircase).
4 Site plan.
5 Elevation of Doors and windows showing its openings and sizes.
6 Staircase Details.
7 Ramp Detail
8 Others (if any)

@_ :6Sr/n gS;fx? M
S. No. Drawings For Framed Structure No. of Sheets
1 Column Reinforcement for critical column (indicate position of the
column in structure)
2 Critical beam reinforcement (indicate position)
3 Slab reinforcement
4 Staircase reinforcement
5 Trench plan and toe wall detail
6 Critical foundation detail (indicate position)
7 Ductile detailing of Beam and column joint
8 Other (if any)

S. No. Drawings for Load Bearing Buildings No.of Sheets


1 Architectural plan of each floor showing vertical steel reinforcement
at critical sections.
2 Trench plan and foundation details
3 Slab reinforcement
4 Wall cross section
5 Others (if any)

#_ :oflg6/L gS;fx? M
S. No. Drawings No.of Sheets
1 Toilet detail plan (each floor)
2 Roof plan
3 Site plan
4 Plans of Underground water tank, Septic tank, Soak pit& Manhole
5 Isometric drawing (flow diagram chart)
6 Section (toilet with duct detail)
7 Drainage detail
8 Fire fighting system.
9 Others (if any)

$_O{n]S6Lsn gS;fx? M
S. No. Drawings No.of Sheets

2
k]h g+=
1 Layout
2 Wiring
3 Schematic
4 Others (if any)

%_ gfkL gS;f M

^_ ejg l8hfOgdf ;+nUg k|fljlws jf k/fdz{bftf ;+:yf jf JolQmsf]


gfd, 7]ufgf M

&_ ejg lgdf{0fdf ;+nUg k|fljlws jf k/fdz{bftf ;+:yf jf JolQmsf]


gfd, 7]ufgf M

*_ ;+nUg k|flalws laa/0f kmf/fdx? M

-s_ cfls{6]Sr/n l8hfOg M 5 5}g


-v_ :6Sr/n l8hfOgStructure Assessment M 5 5}g
-u_ :oflg6/L l8hfOg M 5 5}g
-3_ O{n]S6Lsn l8hfOg M 5 5}g

gf]6 :

!_ :s]nsf] xsdf ;j} gS;fx? !:!)) jf ! = *' x'g' kg]{ / l86]nx? ! :%) jf !
= $' eGbf sdsf] x'g gx'g] . ;fO{6 Knfgsf] xsdf Ps /f]kgL ;Dd !:!)) jf !
= *' / Ps /f]kgL b]vL dfyL !:@)) jf ! = !^ ' x'g' kg]{ .

@_ l8hfO{g ;xdlt k|bfg ug]{ s|ddf lgdf{0f :yn lg/If0f ug'{ kg]{ cfjZos
ePdf ;DalGwt k|fjlwsx?af6 cfjZostf cg';f/ lgdf{0f :yn lg/LIf0f u/fO{g] 5
.

3
k]h g+=
-S'mg} k/fdz{bftf AolQm ;+:yfaf6 l8hfOg jf lgdf{0f ;'k/Lj]If0f x'g] eP
dfq ._

#_ o;} ;fy ;+nUg Architectural, Structural, Sanitary and Electrical gS;fx? g]kfn
O{lGhlgol/ kl/ifb\(NEA)df btf{ ePsf] JolQmn] btf{ g+ pNn]v u/L
b:tvt u/]sf] x'g' kg]{ 5 .
$_ k'/fgf] ejgdf ;+rfng eO{/x]sf] eP ejgsf] Seismic Vulnerability evaluation
/Assessment Reportg]kfn O{lGhlgol/ kl/ifb\ (NEA)df btf{ ePsf] JolQmn]
btf{ g+ pNn]v u/L b:tvt u/]sf] x'g' kg]{ 5 .

4
k]h g+=
k|fljlws ljj/0f kmf/fd
-s_ cfls{6]Sr/n l8hfOg ;DalGw
-;DjlGwt k|fljlws jf k/fdz{bftf jf6 e/fpg' kg]{_
Forms
for
NBC Code 206:2003- Architectural Design Requirements.
(In case of many buildings, fill up the form for main building only)

Type of Building: Lab Block (3-LAB-6-ERMC)


Building Elements As per Submitted Design Remarks
1.0 Staircase
1.1 Min.tread width of staircase 300 mm excluding nosing
1.2 Riser height of staircase 150 mm
1.3 Clear width of staircase 2000 mm
1.4 Height of handrail 900 mm
1.5 Max. no of riser in one Single flight 10 Nos.
1.6 Max. head room under staircase from the nosing 2700 mm
of the tread
2.0 Exit
2.1 Max. travel distance to exit point in each floor 45760 mm
2.2 Min. width of exit door including frame 1200 mm
2.3 Min. height of exit door including frame 2099mm
2.4 Shutter opening of exit door to staircase & Inside
public Passage
2.5 Total width of exit door 4800 mm
3.0 Light and Ventilation
3.1 Min. opening area of window for lighting largest 2.76 sq.m.
habitable room from external wall
3.2 Min. opening area of natural ventilator for largest 1.38 sq.m.
habitable room from external wall
3.3 Min. size of ventilator for water closets and -
bathroom
4.0 Lifts
4.1 Total height of building 11177mm
4.2 Provision of lift. No
4.3 No. of lift per bank -
5.0 Requirement for the physically disabled
5.1 Is there a provision of separate entrance for
disable people next to the primary entrance of a Yes
building
5.2 Max. gradient for wheel chair ramp at entrance 1:12
of building
5.3 Min. width of wheel chair ramp at entrance of 1200 mm
building.
6.0 Parapet heights
6.1 The height of parapet wall & balcony handrail 1000 mm

5
k]h g+=
k|flalws ljj/0f kmf/fdx?
-v_:oflg6/L l8hfOg ;DalGw
-;DjlGwt k|fljlws jf k/fdz{bftfjf6 e/fpg' kg]{_
Forms
for
NBC 208 : 2003--Sanitary and Plumbing Design Requirements

Type of Building :
Description As per Submitted Design Remarks
1. Water Requirement in buildings.
1.1 Water consumption per head per day
1.2 Storage Capacity of Underground
Water Tank
1.3 Storage Capacity of Overhead water tank
1.4 Residual Head at Consumer's Tap
2. Fixture Requirements
2.1Fire Hydrant
a. No of floors (Indoor)
b. Floor area (Indoor)
c. Capacity of wet riser for
underground water tank
d. Vertical fire hydrant riser pipe size
2.2 Toilet for one unit :
Average family size ......................Persons
a. Water closet
b. Tap
c. WashBasin
d.Kitchen sink & dish washers

6
k]h g+=
k|flalws ljj/0f kmf/fdx?
-u_ On]lS6sn l8hfO{g ;DjlGw
-;DjlGwt k|fljlws jf k/fdz{bftfjf6 e/fpg' kg]{_
Formsfor
NBC 207 : 2003--Electrical Design Requirements
( In case of many units, fill up the form for main unit only )
S.No Electrical Elements As per Submitted Design Remarks
1. Rating and sizes
1.1 Minimum size (sq.mm.)of copper cable for light circuit 2.5 sq. mm.
1.2 Minimum size (sq.mm.) of copper cable for power circuit 4.0 sq. mm.
1.3 Wattage of ordinary power socket (2 pin)estimated as 1000 Watt
1.4 Wattage of power socket outlet (3 pin) estimated as 3000 Watt
1.5 Wall thickness of cast iron switch or regulator boxes 3.00 mm.
1.6 Wall thickness of mild steel sheet switch or regulator boxes for up to 1.18 mm.
20cm.X30cm
1.7 Wall thickness of mild steel sheet switch or regulator boxes for above 1.16 mm.
20cm.X30cm
1.8 Depth of the switch or regulator boxes -
2. Maximum number of cables in a conduit
2.1 No. of 2.5 sq.mm.cross-sectional area cable in 20 mm. dia conduit 5 Nos. of cables
2.2 No. of 4 sq.mm. cross-sectional area cable in 20 mm dia conduit 3 Nos. of cables
2.3 No. of 6 sq.mm. cross-sectional area cable in 20 mm. dia conduit 2 Nos. of cables
2.4 No. of 2.5 sq.mm.cross-sectional area cable in 25 mm. dia conduit 10 Nos. of cables
2.5 No. of 4 sq.mmcross-sectional area cable in 25 mm. dia conduit 6 Nos. of cables
2.6 No. of 6 sq.mm.cross-sectional area cable in 25 mm. dia conduit 5 Nos. of cables
2.7 No. of 2.5 sq.mm.cross-sectional area cable in 32 mm. dia conduit -
2.8 No. of 4 sq.mm.cross-sectional area cable in 32 mm. dia conduit -
2.9 No. of 6 sq.mm.cross-sectional area cable in 32 mm. dia conduit -
3. Earthing
3.1 The value of any earth system resistance unless otherwise specified 5.00 ohm
3.2 Diameter of rod electrodes of steel or galvanized iron -
3.3 Diameter of rod electrodes of copper -
3.4 Internal diameter of pipe electrodes of galvanized iron or steel -
3.5 Internal diameter of pipe electrodes of cast iron -
3.6 The B17length of the rod & pipe electrodes -
3.7 Thickness of plate electrodes of galvanized iron or steel -
3.8 Thickness of plate electrodes of copper 3.15 mm
3.9 Size of plate electrodes of galvanized iron or steel or copper 60 cm x 60 cm
3.10 Depth of the top edge of plate electrodes buried from ground 1.50 m.
4. Testing
4.1 Insulation resistance (M ohm) between earth and the whole system of 50/No points on the circuits .
conductor or any section thereof
4.2 Insulation resistance (M ohm) between the metallic case and all live 1/2 M ohm
parts of each rheostat, appliance and sign when they are disconnected,
4.3 Insulation resistance (M ohm) between all the conductors connected 50/No Points in the
to one pole or phase conductor and all the conductor connected to the Circuits
middle wire or to the neutral or to the other pole of the phase
conductor
4.4 The applied dc voltage (Volt)of meggering 2 x Working voltage
4.5 Each switch is placed in phase or neutral? Switch in phase
Note :
1. When substation and external electrical works are required, designer must comply NBC 207: 2003 or/and
relevent international electrical codes.

7
k]h g+=
2. Designer is advised to consider lightning protection designated by international electrical codes .

k|fljlws ljj/0f kmf/fdx?


-3_ :6Sr/n l8hfOg ;DalGw
-;DjlGwt k|fljlws jf k/fdz{bftfjf6 e/fpg' kg]{_
Forms
for
NBC 000:1994 to NBC114:1994 Professionally Engineered Buildings
(In case of many units, fill up the form for main unit only)

Type of Building: Classroom Block (3-LAB-6-ERMC)


S.N. Description As per submitted design Remarks
1. General:
Number of Storey 3
Total height of structure 10.727 m
Structure system Frame Load bearing Other
If Computer Aided Design AutoCAD 2013, ETABS 2016
(CAD) is used, please state
the name of the package
2. Requirements of NEPAL NATIONAL BUILDING CODE (NBC)
2.1 NBC-000-1994 Requirements for State-of-the Art Design : An Introduction
Level of design: International State-of-the-art
Professionally Engineered Structures
Mandatory Rule of thumb
Guidelines to rural buildings
2.2 NBC 101:1994 Materials Specifications
Tick the listed materials that Cement Coarse Aggregates
will be used in the Fine Aggregates (Sand) Bricks
construction Natural building stones Timber
Tiles Structural steel
Metal frames

In what manner / way have Material specification


you used NBC 101 ?
2.3 NBC 102-1994 Unit Weight of Materials
Where do you plan to apply Specifications
NBC 102 ? Design Calculation
Bill of Quantity
Specify the design unit weight
of materials
Steel 78.50 KN/m3
Brick 19 KN/m3 (IS 875,1987)
RCC 25 KN/m3
Brick Masonry 20.4 KN/m3
Note: *If any materials other than specified in NBC 102-1994, the designer should take responsibility that such
materials are according to international standard.
2.4 NBC 103-1994 Occupancy load (Imposed Load)
Proposed occupancy type Occupancy load
(Fill in only concerning Uniformly Distributed load Concentrated Load (kN)
occupancy type) (kN/m2)
For Educational Building
(Classroom 3-Combined-22-
ERMC)
Rooms 3
Corridors, Staircase, store 4
Balcony 4
2.5 NBC 104-1994 Wind load

8
k]h g+=
S.N. Description As per submitted design Remarks
Wind zone
Basic wind velocity
2.6 NBC 105-1994 Seismic Design of Buildings in Nepal
Method of earthquake analysis: Seismic coefficient method
Model Response Spectrum
Method
Subsoil category Type II IS 1893,2002
Fundamental transactions period 0.516 IS 1893,2002
Basic seismic coefficient 0.135 IS 1893,2002
Seismic zoning factor 0.36 (Zone 5) IS 1893,2002
Importance factor 1.5 IS 1893,2002
Structural performance factor

2.7 NBC 106 : 1994 Snow load


Snowfall area Perennial Snowfall Occasional
No
Elevation No
Design Depth No
Design Density No
2.8 NBC 107: 1994 Provisional Recommendation on Fire Safety
Where do you plan to apply the fire Specifications
safety requirements specified in NBC Design Calculation
107 and NBC 206 1994? Bill of quantity
2.9 NBC 108: 1994 Site Consideration for Seismic Hazards
Distance from toe/beginning of
downward slope (if applicable) m
Distance from river bank
Soil type in footing
Adopted safe bearing capacity 50 kN/m2,100 kN/m2 ,150 kN/m2 and 150
kN/m2
Type of foundation ISOLATED FOOTING, AND RAFT
FOOTING
Depth of foundation Minimum 1.8m (Depend on the site
condition)
Soil test report available? No
Note: Soil test is advisable for all professionally engineered structures. In case, soil test is not carried out, the
designer should take responsibility for assumed data concerning site consideration.
2.10 NBC 109 : 1994 Masonry : Unreinforced
Concrete Grade
Brick crushing strength
Mortar ratio for load bearing masonry

Floor Wall height Wall thickness Maxi


mum
Lengt
h
Ground floor
First floor
Second floor


Opening details:
Least distance from inside corner
Does the total length of opening in any Yes No
wall exceed 50 % of its length
Does the horizontal distance between Yes No
any two opening less than 600 mm or
of height of shorter opening
Does the Vertical distance between two Yes No
opening less than 600 mm or of
width of smaller opening

9
k]h g+=
S.N. Description As per submitted design Remarks

If any of above mentioned cases do not Yes No


comply, do you have provision for
strengthening around opening?
Bands provided: Plinth level
Lintel level
Roof level
C/C distance of corner/tee
strengthening Horizontal dowel bars
2.11 NBC 110 : 1994 Plain and Reinforced Concrete
Concrete grade M20
Reinforcement Steel Grade FE500
Critical size of slab panel 2.65x 2.615
Calculated short span to effective depth 26.5
ratio (L/d) for corresponding slab
Permissible L/d ratio 52
Effective depth 100
Span correction factor
Tension reinforcement 2
modification factor
Compression reinforcement 1
modification factor
Beam characteristics Condition of beams
Cantilever Simply One side Both side
supported Continuous continuous
Maximum span/depth ratio 10.46 10.46
Span of corresponding beam 5.23 5.23
Depth of corresponding beam 500 500
Width of corresponding beam 350 350
Maximum slenderness ratio of column 6.67

Lateral dimension of corresponding 450x450


column
Design Philosophy: Limit State method

Load Combinations: As per IS 1893:2002 EL


1: 1.5(DL+LL) (Both x
and y
2: 1.2(DL+LL+EL) direc.)
3: 1.5(DL+EL)
4: 0.9DL+1.5EL
2.12 NBC : 111-1994 Steel
Design assumption: Simple connection
Semi-rigid connection
Fully rigid connection
Yield Stress:
Least wall thickness
Exposed condition Pipe Webs of Composite
Standard size section
For Exposed Section
For not exposed section
Have you used Truss? No
What is the critical span of purlin
Purlin size
Have you used steel post? No
Slenderness ratio of the critical post

2.13 NBC : 112 Timber


Name of structural wood:
Modulus of Elasticity:

10
k]h g+=
S.N. Description As per submitted design Remarks
Critical span of the beam element
Designed deflection
Slenderness ratio of the critical post
Joint type:
2.14 NBC : 113 : 1994 Aluminium
Have you used aluminium as structure Yes
member? No
If yes, please mention the name of
design code.
2.15NBC : 114 : 1994 Construction safety
Are you sure that all safety measures Yes
will be fulfilled in the construction site
as per this code?
Safety wares use Safety hard hat
Safety goggles
Safety boots
Safety belt
First aid facility

11
k]h g+=
ldlt M ===================
>Ldfg\ dxflgb]{zsHo",
zx/L ljsf; tyf ejg lgdf{0f ljefu.

ljifo M k|ltj4tf kq .
s_k/fdz{bftfsf] tk{maf6 M
;+:yfks
>L===========================================n]
lhNnf==================================g=kf=uf=lj=;=
=======================j8f
g+========:yfg========================sf] hDdf hUufsf]
If]qkmn ==========================/f]kgLju{ld6/df ejg P]g
@)%%, ejg lgdofjnL @)^^, ejg lgdf{0f dfkb08 @)^$, g]kfn /fli6o ejg
;+lxtf @)^) / ;f] df pNn]v gePsf Standard ;DaGwdf InternationalStandard sf]
clwgdf /lx ejg ;+Vof ======== j6f e"ldut tNnf /x]sf] / ;f] eGbf dfly
=========== clwstd tNnf ePsf]========== ju{ld6/ju{ lkm6 Built

up AreaePsf]gofF ejg lgdf{0fgljs/0f:yfg kl/jt{g:t/f]GgtL Pj+


pkof]u kl/jt{gsf]
k|of]hgsf]Architectural/Structural/Sanitary/Electrical/FireSafetysf gS;fx? / k'/fgf]
eP l/kf]6{x?Analysis, Design,Assessment, DatadxfdLaf6 tof/ u/L k]z u/]sf]
5'5f}+ .
Designers SignatureNameNEC NO.
1. Architect : Ar. Sudeep Shakya
2. Structural Engineer : Dr. Purushotam Dangol
3. Sanitary Engineer :
4. Electrical Engineer :

Date : -----------------------
sDkgLsf]
k/fdz{bfqL ;+:yfsf] gfd M 5fk
k|f]k|fO{6/sf] gfd tyf x:tfIf/ M

12
k]h g+=
------------------------------------------------------------------------------------------------------------------------------

13
k]h g+=
v_ lgdf{0f sfo{ ;'k/Lj]Ifssf] tk{maf6 M

;+:yfks
>L===========================================n]
lhNnf==================================g=kf=uf=lj=;=
=======================j8f
g+=======:yfg=======================dfgofF ejg
lgdf{0fgljs/0f:yfg kl/jt{g:t/f]GgtL Pj+ pkof]u kl/jt{gsf]
k|of]hgug{ nfu]sf], k/fdz{bfqL
=====================================sf tk{maf6
>L===============================n] l8hfOg u/]sf] ejgsf]
lgdf{0f sfo{sf] k|fljlws ;'k/Lj]If0fdf :jLs[t gS;f adf]lhd ug]{ u/fpg]k|ltj4tf
k]z u/]sf 5'5f} .

DesignerNameNEC NO.Signature
5. Architect : Ar. Sudeep Shakya
6. Structural Engineer : Dr. Purushotam Dangol
7. Sanitary Engineer :
8. Electrical Engineer :

Date : -----------------------
sDkgLsf]
;'k/Lj]If0f ug]{ ;+:yfsf] gfd / 7]ufgf M 5fk
k|f]k|fO{6/sf] gfd tyf x:tfIf/ M
----------------------------------------------------------------------------------------------------------------------------------
--

14
k]h g+=
u_ ;+:yfkssf] tk{maf6 M
Architectural/Structural/ Sanitary/Electrical/Fire Safetysf gS;fx?l8hfO{g cg';f/ dfly
pNn]lvt k/fdz{bfqLsf] k/fdz{ tyf k|fljlws ;'k/Lj]If0f lnO{ ejg P]g @)%%,
ejg lgodfjnL @)^^, ejg ;+lxtf @)^) adf]lhd lglb{i6 u'0f:t/ sfod /fvL
lgdf{0f sfo{ ug{,u/fpg / lgdf{0f sfo{ ePsf] k|ltj4tf hfx]/ ub{5'ub{5f} .
em'f ljj/0f k]z u/]sf] 7xl/Pdf / :jLs[t gS;f, l8hfO{g, :6of088{; /
:k]l;lkms]zg adf]lhd lgdf{0f sfo{ km/s kfO{Pdf k|rlnt sfg"g jdf]lhd
;hfosf] eflubf/ x'g,Joxf]g{ d~h'/ ePsf] Aoxf]/f ;d]t o;} k|ltj4tf kq4f/f
cg'/f]w ub{5'ub{5f} .

;+:yfkssf] gfd M
7]ufgf M
kmf]g g+= M sDkgLsf]
x:tfIf/ M 5fk
ldlt M

15
k]h g+=