GENERAL NOTES AND SPECIFICATIONS: MATERIAL SPECIFICATIONS:

1. IT IS NOT INTENDED THAT THE DRAWINGS SHALL SHOW EVERY PIPE


FITTING, VALVE AND APPURTENANCE. ALL SUCH ITEMS WHETHER
COLD WATER LINE SHALL BE POLYPROPYLENE RANDOM (PPR) TYPE 3 PIPE,
SPECIFICALLY MENTIONED OR NOT, OR INDICATED ON THE DRAWINGS
"WAVIN EKOPLLASTIK" BRAND OR APPROVED EQUAL.
SHALL BE FURNISHED AND INSTALLED IF NECESSARY TO COMPLETE THE
SYSTEM TO THE SATISFACTION OF THE OWNER.
VENT PIPES SHALL BE POLYVINYL CHLORIDE (PVC) PIPE SERIES 1000,
2. ALL PLUMBING WORKS SHALL BE INSTALLED IN ACCORDANCE WITH THE
"NELTEX", "ATLANTA" BRAND OR APPROVED EQUAL..
PROVISION OF THE NATIONAL PLUMBING CODE OF THE PHILIPPINES, THE
REQUIREMENTS OF THE LOCAL PLUMBING INSPECTION OFFICE, PERTINENT
FITTING SHALL BE SOLVENT CEMENT JOINT TO ASTM D2564.
PROVISIONS OF THE UNIFORM BUILDING CODE AND THE NATIONAL
BUILDING CODE OF THE PHILIPPINES.
SEWER LINES SHALL BE POLYVINYL CHLORIDE (PVC) PIPE SERIES 1000,
"NELTEX", "ATLANTA" BRAND OR APPROVED EQUAL.
3. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND
FITTINGS SHALL BE SOLVENT CEMENT JOINT TO ASTM
SPECIFICATION. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY
D2564.
DESCREPANCY FOUND THEREIN.
4. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS, ANY
STORM
RELOCATIONS REQUIRED FOR PROPER EXECUTION OF OTHER TRADE
DRAINAGE LINES/
SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER.
DOWNSPOUT SHALL BE POLYVINYL CHLORIDE (PVC) SERIES 1000,
5. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL
"ATLANTA" BRAND OR APPROVED EQUAL. FITTING SHALL BE
LOCATION, DEPTH AND INVERT ELEVATION OF ALL EXISTING PIPES AND
STRUCTURES AS VERIFIED BY THE CONTRACTOR.
MATERIAL SHALL BE CONCRETE DRAIN PIPE (CDP) TONGUE
6. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% UNLESS
@ GROOVE, MORTAR JOINTS, REINFORCED
OTHERWISE SPECIFIED.
7. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE
WITH MANUFACTURER'S INSTRUCTIONS.
AHU/FCU LINES SHALL BE POLYVINYL CHLORIDE (PVC) PIPE SERIES 600 II,
8. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT THE SITE,
"NELTEX", "ATLANTA" BRAND OR APPROVED EQUAL.
COORDINATE THE WORKS WITH THE SEWER LINE EFFLUENT DISPOSAL
POINT AND WATER LINE SERVICE CONNECTING POINT, UNLESS OTHERWISE
FITTINGS SHALL BE SOLVENT CEMENT JOINT TO ASTM D2564.
SPECIFIED. ISOMETRIC
9. ALL FIXTURES SHALL BE INDIVIDUALLY VENTED. CHECK VALVES "GREAT VOLUME"," CRANE", "KITS", OR APPROVED EQUAL. WATERLINE LAYOUT
10. THE INVERT OF THE INLET PIPE OF A SEPTIC TANK SHALL BE AT A LEVEL SCALE 1:50 MTS
NOT LESS THAN 50.8mm (2") ABOVE THE INVERT OF THE OUTLET PIPE. GATE VALVES "GREAT VOLUME","CRANE", "KITS", OR APPROVED EQUAL.
11. TO PREVENT CONTAMINATION OF UNDERGROUND WATER SOURCE NO
4400
SEPTIC TANK SHALL BE CONSTRUCTED LESS THAN 1.20m ABOVE THE WATER METER "ARAD", "ASAHI" BRAND OR APPROVED EQUAL.
WATER TABLE LEVEL. 200 1800 200 900 200 900 200
12. ALL PIPE SIZE ARE IN MILLIMETERS AND ALL DIMENSIONS ARE IN METERS
UNLESS OTHERWISE SPECIFIED.
13. MINIMUM SEWAGE PIPE SIZE SHALL BE AS FOLLOWS:
SOIL PIPE

200
WASTE PIPE SV SHOWER VALVE CWR COLD WATER RISER
VENT PIPES KS KITCHEN SINK VSTR VENT STACK THRU ROOF
DOWNSPOUT LT LAUNDRY TRAY CO CLEAN OUT
14. ALL PLUMBING INSTALLATION INCLUDED HEREIN SHALL BE UNDER THE F FAUCET SD SHOWER DRAIN
DIRECT SUPERVISION OF A DULY REGISTERED AND LICENSED MASTER VP VENT PIPE
FD FLOOR DRAIN
PLUMBER. WP WASTE PIPE
HB HOSE BIBB
SP SOIL PIPE
PLUMBING LEGEND: WC WATER CLOSET
MV MAIN VENT

1600

1200
LAV LAVATORY
VAC VENT ABOVE CEILING
GATE VALVE STORM DRAIN PIPE BT BATH TUB
FCO FLOOR CLEANOUT
FB FOOT BATH
CHECK VALVE VENT PIPE UFV UNDER FLOOR VENT
M WATER METER HRP HORIZONTAL
CB CATCH BASIN RAINWATER PIPING ISOMETRIC
CWL
COLD WATERLINE
CP
DS
CONDENSATE PIPE
DOWNSPOUT
SANITARY SEWAGE LAYOUT

200
DS DOWNSPOUT SCALE 1:50 MTS
WASTE PIPE RD ROOF DRAIN

SOIL PIPE
PLAN
A B C D E F A B C D E F
25000 25000

5000 5000 5000 5000 5000 5000 5000 5000 5000 5000

10025
1 1

300

300
AIR SPACE
AIR SPACE AIR SPACE
WATER LEVEL

51
7000

WATER LEVEL

51
WATER LEVEL

51
14000

1550
2 2

1000
7000

INLET SECONDARY TERTIARY


COMPARTMENT COMPARTMENT COMPARTMENT

3 3

150
SECTION

SANITARY SEWAGE LAYOUT WATERLINE LAYOUT SEPTIC TANK DETAILS


SCALE 1 : 200 M SCALE 1 : 200 M SCALE 1:20 MTS

Prepared by: Checked by: Approved by: PROJECT NAME : Sheet Content: DRAWN BY: JMG Revisions: Sheet No.:
REPUBLIC OF THE PHILIPPINES
CHECKED BY: CFQ/JCC
DEPARTMENT OF TRANSPORTATION AND MATI AIRPORT DEVELOPMENT PROJECT (C.Y. 2015) P-1
COMMUNICATIONS JULIUS C. CARLOS DATE DRAWN: 2016
PROJECT DEVELOPMENT SERVICE Engineer IV, Project Development Service PROJECT SCOPE: 1 1
REHABILITATION OF EXISTING TERMINAL BUILDING
DATE PRINTED: 2016 Total Sheet No.:
UNIT 83, THE COLUMBIA TOWER, BRGY. WACK WACK,
ORTIGAS AVENUE, MANDALUYONG CITY 1555
LOCATION : MATI, DAVAO ORIENTAL SCALE : AS SHOWN DATE APPROVED: 2016 09 / 10
The copyright of this drawing remains the property of the Department of Transportation and Communications whose permission must be obtained before any use of it can be made.
A B C D E F A B C D E F

25000 25000

5000 5000 5000 5000 5000 5000 5000 5000 5000 5000

5000

4300
4400

1 1

7000
14000

2 2
7000

3 3

PROPOSED PROPOSED
FOUNDATION PLAN ROOF BEAM PLAN
SCALE 1 : 150 M SCALE 1 : 150 M

COLUMN 1 DETAIL BEAM 1 DETAIL FOUNDATION PLAN FOUNDATION SECTION


SCALE 1 : 10 M SCALE 1 : 10 M SCALE 1 : 20 M SCALE 1 : 20 M

Prepared by: Checked / Submitted by: Approved by:


O RTAT I O N
SP
Republic of the Philippines
A
N
A

DAHICAN AIRPORT DEVELOPMENT PROJECT (C.Y. 2015) S- 1


D
T O F TR

CO M M U N

DEPARTMENT OF TRANSPORTATION AND COMMUNICATIONS JULIUS C. CARLOS DEO LEO N. MANALO


* AS SHOWN * 01 03
EN

Office of the Director Engineer IV, Project Development Service Director, Project Development Service
TM

IC

AT
R
REHABILITATION OF EXISTING TERMINAL BUILDING
IO
N S DE PA
Project Development Service
The Columbia Tower, Ortigas Ave., Mandaluyong City, Metro Manila
06 / 10
The copyright of this drawing remains the property of the Department of Transportation and Communications whose permission must be obtained before any use of it can be made
TRUSS 2 DETAIL
SCALE 1 : 50 M
TRUSS 1 DETAIL
SCALE 1 : 50 M

TRUSS 3 DETAIL TRUSS 4 DETAIL TRUSS 5 DETAIL TRUSS 6 DETAIL


SCALE 1 : 50 M SCALE 1 : 50 M SCALE 1 : 50 M SCALE 1 : 50 M

Prepared by: Checked / Submitted by: Approved by:


O RTAT I O N
SP
Republic of the Philippines
A
N
A

DAHICAN AIRPORT DEVELOPMENT PROJECT (C.Y. 2015) S- 2


D
T O F TR

CO M M U N

DEPARTMENT OF TRANSPORTATION AND COMMUNICATIONS JULIUS C. CARLOS DEO LEO N. MANALO


* AS SHOWN * 02 03
EN

Office of the Director Engineer IV, Project Development Service Director, Project Development Service
TM

IC

AT
R
REHABILITATION OF EXISTING TERMINAL BUILDING
IO
N S DE PA
Project Development Service
The Columbia Tower, Ortigas Ave., Mandaluyong City, Metro Manila
07 / 10
The copyright of this drawing remains the property of the Department of Transportation and Communications whose permission must be obtained before any use of it can be made
NOTE:
REINFORCING BAR FOR SLAB OPENING
OPENING SIZE VERTICAL & HORIZONTAL

UNDER 600

UNDER 800

Prepared by: Checked / Submitted by: Approved by:


O RTAT I O N
SP
Republic of the Philippines
A
N
A

DAHICAN AIRPORT DEVELOPMENT PROJECT (C.Y. 2015) S-3


D
T O F TR

CO M M U N

DEPARTMENT OF TRANSPORTATION AND COMMUNICATIONS JULIUS C. CARLOS DEO LEO N. MANALO


* AS SHOWN * 03 03
EN

Office of the Director Engineer IV, Project Development Service Director, Project Development Service
TM

IC

AT
R
REHABILITATION OF EXISTING TERMINAL BUILDING
IO
N S DE PA
Project Development Service
The Columbia Tower, Ortigas Ave., Mandaluyong City, Metro Manila
09 / 10
The copyright of this drawing remains the property of the Department of Transportation and Communications whose permission must be obtained before any use of it can be made

Вам также может понравиться