SOLUTION 1:
1. Type CUI in the command line, then press ENTER
2. In the upper left corner under "customizations into all files" you will find an icon called "Partial
Customization Files", extract the tree structure using the plus sign
Here you should find an icon called "MAGICAD"
3. Right-click the icon MAGICAD and press Unload if it is unresolved.
(See picture)
4. Press OK to close the dialog
5. Restart AutoCAD
SOLUTION 2
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
3 (27)
2016-06-07
SOLUTION 3:
1. In case the problem persists uninstall MagiCAD and manually delete/remove folder
(C:\ProgramData\MagiCAD\Support) and all its contents:
2. Reinstall MagiCAD and start it as administrator for first time
A: You cannot change the color of a specific object, but you can change the color of his layer. You have
the possibility to choose between the color from AutoCAD, and By system and By layer
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
4 (27)
2016-06-07
When you choose By layer you should use multiple layers for the object. The lines of the object will be
separate in different layers: Centerline, 1D/2D Edge Line and 1D/2D Details.
You must determine a Layer name, a Type, a Color and a Line weight.
If you want to explode only Electrical objects: Run the MagiCAD command MEEXPLODE, check the
object types (corresponding checkboxes) that you want to explode directly to simple primitives (uncheck
object types that you want to explode to blocks), click Ok and finally select the objects that you want to
explode.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
5 (27)
2016-06-07
NOTE! It is recommended to explode devices and other symbols to blocks and all other object types to
simpler primitives (like selected in the picture above). Use the FLATTEN command of AutoCAD's (free)
Express Tools to flatten an exploded 2D drawing.
A: One way to do this. Go to AutoCAD's own Manage text styles. Create one you want there and apply
it. Then you can add it to MagiCADs Text styles and use it.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
6 (27)
2016-06-07
A: The Xref should be located in the MAGI_GARBAGE layer. Put the xref in another layer, preferably in
a separate layer that you can lock.
A: If you use MagiCAD for AutoCAD you can load your project in Revit via IFC, and vice versa.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
7 (27)
2016-06-07
MAGICREATE
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
8 (27)
2016-06-07
After that, in the database, choose Local instead Cloud, and search your file in the data source.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
9 (27)
2016-06-07
A: MagiCAD Plugin Manager enables to download and install specialist MagiCAD plugins and
manufacturer-specific product plugins. With these plugins you can select AHU, floor drains, silencers,
etc.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
10 (27)
2016-06-07
A: By following steps below you should be able to use the move function succefully.
Be sure that the layer of the object you want to move is not locked.
If you dont find the layer of your object. Open project and go in the Layer settings of the category of
the object. See if any of the rows in the column layers is empty (except for insulation). If yes, write a
Layer code.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
11 (27)
2016-06-07
When you are done it, just run Updating Drawing Data, mark Color, line type, and line weight settings
of the object option.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
12 (27)
2016-06-07
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
13 (27)
2016-06-07
With this tool, you can modify size and technical characteristics of a generic product, to create a device
corresponding to you own wishes.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
14 (27)
2016-06-07
After that, in the database, choose Local instead Cloud, and search your file in the data source.
You can also use the function Set MagiCAD Data to AutoCAD Objects on one of an AutoCAD block
that you created.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
15 (27)
2016-06-07
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
16 (27)
2016-06-07
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
17 (27)
2016-06-07
A: You can use either ACADs publish function to print out the desired pages after you have created
them with Layout function Batch Plot.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
18 (27)
2016-06-07
But you can also use the MagiCAD PDF export function if wanted.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
19 (27)
2016-06-07
A: Ensure that the *.lin file is in the same folder as the other project files (*.qpd, *.epj) and make sure it
has the same name as these other files.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
20 (27)
2016-06-07
If, when you reopen AutoCAD later, the ribbons are again not here. Use the AutoCAD command: cui
and load these same files from the same path in the partial customization file.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
21 (27)
2016-06-07
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
22 (27)
2016-06-07
A: After you have made the switchboard, you cant remove column, you need to remove it before.
In project management there is Switchboard definitions. There you define your switchboard schematic
template. And there you define which columns is included. But if you make a change, you should re-
create you schematics.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
23 (27)
2016-06-07
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
24 (27)
2016-06-07
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
25 (27)
2016-06-07
A: When you install MagiCAD for AutoCAD, you can open the different models Dataset, without opening
AutoCAD.
With these utilities, engineers who dont draw or design, can manage the project. We have also another
tools, called product browser which allow to see all objects in our database.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
26 (27)
2016-06-07
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com
27 (27)
2016-06-07
A: When you have done the sizing and the balancing calculation of your network you can use the
function Part property on the open end of the supply pipe! You can also double-click on the open end
to evoke the property dialog.
Progman Oy, Nortamonkatu 1, 26100 Rauma, Finland | Tel. +358 2 8387 6000 | www.magiclad.com | support@magicad.com