Вы находитесь на странице: 1из 80

WQ Series Submersible Sewage Pump

Company Profile

Shanghai Kaiquan Pump (Group) Co., Ltd. is a leading enterprise Construction. In 2013, Kaiquan was selected as one of Chinas top
specializing in the design, production and sale of pumps, water-supply 500 organisations in the mechanical industry for the third consecutive
facilities and pump control equipment. Kaiquan boasts assets year, coming first place in the pump industry nationwide.
exceeding 2.5 billion yuan, with 7 enterprises and 5 industrial parks in
Shanghai, Zhejiang, Hebei, Liaoning and Anhui, covering a total area Dedication to excellent customer service is one of Kaiquans core
of nearly 67 hectares, and a building area of 350,000 square meters values. The groups 300 service-dedicated engineers provide
for production. comprehensive expert solutions for customers, and with the use of the
latest technology, are able to respond highly efficiently to client
For 12 consecutive years Kaiquan has achieved the highest volume of requests. In addition, Kaiquans extensive national service network,
sales within Chinas domestic pump industry. The companys success composed of 32 sales branch companies and 361 agencies allows
has far outstripped that of its competitors, with Kaiquans profits the company to execute its Blue Fleet Services programme -
reaching 3 billion yuan in 2013 - twice that of the nearest competitor. allowing experienced technicians to respond to customer requests at
The companys role as market leader of Chinas pump industry is any time of day, within a turnaround time of just 4 hours. This attention
reflected in the quality of its people. 80% of the groups 5,000 strong to the needs and aspirations of customers has ensured Kaiquans role
workforce are college graduates, and amongst them are more than as Chinas leading producer of competitive and reliable products
750 engineering technicians comprising some of Chinas best-known within the pump industry.
experts, professors and senior engineers.
Kaiquans vision for the future is to expand the groups activities with
Kaiquans excellence in business and engineering has been the localized production of high-end pump products for application
recognised with the following accolades: Shanghai Quality Golden within a diverse range of fields and projects, such as those related to
Prize, the fourth place in Top 100 Shanghai PVT Enterprise, Shanghai nuclear power, large-scale fire power, petrochemical engineering,
Top 100 Technical Enterprise, Grade AAA China Quality Credit, Grade military projects and sea water desalination. Shanghai Kaiquan seeks
AAA National Contract Credit, Excellent Enterprise in Quality, to become a world famous brand, and intends to become a
Creditability and Services, Chinas Most Competitive Commodity multinational corporation and a top 10 contender in the global pump
Trademark, and Advanced Unit of National Enterprise Cultural market.
Table of Contents

Product Overview 01
Main Applications 01
Working Conditions 01
Advantages and Features of WQ Series Submersible Sewage Pump 01
Diagram and Structural Description of WQ Series Submersible Sewage Pump 02
Materials of Main Pump Parts 05
Installation Modes 05
Technical Description 07
Terminal Box and Wiring Conduit of (Level) Float Switch for Special Electric Cabinet of
Submersible Sewage Pump 12
Ordering Description 14
Supply Checklist 15
Spectrum Diagram and Description of WQ Series Submersible Sewage Pump 16
Performance Specification of WQ Series Submersible Sewage Pump 17
WQ series submersible sewage pump performance curve, main parameters,
installation dimensions 21
Descriptions of Accessories 71
Specialists in Pumps for
More Than 20 Years.

Product Overview
The new generation WQ series submersible sewage pump is In addition, the comprehensive design optimization is applied in terms
developed by Shanghai Kaiquan in accordance with national standard of mechanical structure, wiring, sealing, protection, and control to
GB/T24674-2009 Waste Submersible Motor Pumps, and has been realize higher configuration and better hydraulic performance,
designed by drawing upon the strengths of similar products at home universality, and reliability.
and abroad. The product represents the integration of the existing
sewage pump series. With its innovative overloading-proof hydraulic
model, its truly a full-lift submersible pump.

Main Applications
Its mainly applied for pumping of sewage, waste water, and rainwater pump stations, water supply plants, irrigation and drainage projects,
with solid matters in sewage treatment plants, municipal sewage lift diversion projects, and integrated pump stations.

Working Conditions
1. The medium shall be no higher than 40C in temperature, 4. The diameter of solid contents in the medium should be less than
1050kg/m3 in density, and within 4-10 in PH value. the minimum size of the flow passage. Please refer to the
2. The liquid level should not be lower than the symbol shown in Performance Specification of WQ Series Submersible Sewage
the installation dimension diagram during the running of the pump. Pump for specific sizes of solid contents.
3. As its main parts are made of cast iron or ductile cast iron, this 5. The length of fibers contained in the medium should be smaller than
pump cant be applied for the pumping of medium with strong the discharge diameter of the pump.
corrosiveness or containing strong corrosive solid particles.

Advantages and Features of WQ Series Submersible


Sewage Pump
I. Innovated technology of unique overloading-proof hydraulic design 1. The mechanical seals are applied with self-cleaning technology.
for sewage treatment pump Two one-sided mechanical seals are installed in series and special
1. The innovative high-efficiency overloading-proof hydraulic model spiral groves or small gaps are adopted at the pump covers to prevent
design concept also takes into account the flow capacity of the the deposit of solid contents surrounding the mechanical seals and
sewage pump; effectively troubleshooting any operational issues. thereby guarantee their stable working performance.
2. Innovative overloading-proof hydraulic model ensures the 2. The short shaft extension features fortified strength and improved
maximum power output point within the high-efficiency zone, ensuring resistance against breakage.
stable operation and minimal vibration. 3. The pump head mechanical seals are made of silicon carbide -
3. Impellor capacity: Comprehensive CFD research, analysis, and tungsten carbide to provide maximum resistance to wear and a longer
testing is implemented so as to ensure that the impellor achieves the service life.
best balance between impeller blades and solid content flow-through 4. The motor is of insulation grade H (applicable for 180C) improving
capacity, with the unique design of the flow passage parts reliability and the resistance of the winding to higher temperatures.
guaranteeing smooth passage of solid contents and anti-winding The submersible motor of insulation grade H features higher
performance of fibers. durability.
II. Unique water pump sealing design for guaranteed long-term 5. With design of heavy-duty bearings, the minimum service life is
reliable running of pump 100,000h for the bearings.

WQ Series Submersible Sewage Pump


III. High-end water pump material configuration, for the pursuit of against leakage and winding overheating, power-off protection in the
higher quality event of short-circuit, overload, and phase loss, and precisely controls
The standard configuration of pump includes a cold rolled silicon steel start, stop, alternation, and minimum immersion depth of pumps under
motor of insulation grade H, wear-resistant nodular cast iron flow unattended condition, accurately analyzing the running malfunctions
passage parts, SKF bearings, Burgmann mechanical seals, and of the motor to guarantee safe, reliable, and trouble-free usage of the
stainless steel lifting brackets and fastening bolts, featuring high grade pump.
configuration and better running reliability. V. Universal pump installation design for diversified installation modes
IV. Intelligent water pump control system for embodiment of industrial The automatic coupling installation mode realizes the connection
4.0 technology application between pump and discharge pipeline via the discharge pipe seat of
The perfect combination of special electric cabinet, level float switch coupling without the use of conventional fasteners. To couple or
and pump protection units, and the optional German imported PTC uncouple the pump from the discharge pipe seat, simply lower or lift
motor protection module allows automatic monitoring and warning the pump along the guide rod, an easy and time efficient approach.

Diagram and Structural Description of WQ Series


Submersible Sewage Pump
Diagram of 11kW~22kW submersible sewage pumps Structural description of 11kW~22kW submersible sewage pumps

8 7

10 6

5
11

4
12

3
13

2
5

1
14

1. Pump body 2. Impellor 3. Pump cover 4. Mechanic seal 5. Oil-water probe 6. Bearing
7. Handle 8. Cable 9. Cable seal 10. Wiring board 11. Motor 12. Screw plug and filler port
13. Oil chamber 14. Seal ring

01/02
Specialists in Pumps for
More Than 20 Years.

Structural diagram of 30kW submersible sewage pumps Structural diagram of 30kW submersible sewage pumps

The cable protection jacket


of unique double cable inlet
sealing technology is installed
to seal and isolate the wiring
upper end cap from motor
chamber to prevent water
The lifting bracket and seepage into the motor.
standard parts made
of stainless steel 304

The motor insulation grade is 9


Imported SKF bearing
as standard upgraded from grade F to
configuration grade H, which has an
insulation margin 60 higher 10
than the grade F.
11
Optional German
imported PTC
thermometer and
modules
Special three-layer
VPI for submersible
motor
8

The Burgmann mechanical 12


seals made of silicon carbide/ 7
ungsten carbide are applied,
Design optimization for with self-cleaning technology.
13
bearing structure, with
service life of 100,000 6
hours
The single-adapted coupling 5
frame is compatible with the
installation dimensions of imported 4
submersible pumps
Perfect overloading- 3
proof full-lift hydraulic
model is highly energy 2
efficient passage parts, pump body, 14
impellor, and pump cover
are made of wear-resistant, 15 1
corrosion-resistant, and high
strength QT500 16

17
18

19

20

1. Pump body 2. Impellor 3. Pump cover 4. Mechanic seal 5. Water leakage probe 6. Bearing
7. Motor upper end cover 8. Wiring box 9. Control cable 10. Lifting bracket 11. Power cable
12. Housing 13. Motor 14. Oil-water probe 15. Connecting seat 16. Screw plug and filler port
17. Key 18. Impeller pressure plate 19. Impellor lock nut 20. Seal ring

Structural Descriptions
Pump body and impellor
The design optimization of CFD technology achieves the best balance between overloading-proof hydraulic design and high flow capacity,
featuring a broad flow passage and improved flow-capacity of waste. The impeller has passed a strict dynamic balance test to minimize vibration
and maximize the service lives of bearings and mechanical seals.
Motor
The specially designed and manufactured submersible motor is of IP68 protection grade, the stator winding is of insulation grade H, and the
maximum working temperature of the insulation materials is 180C. The winding is internally installed with an overheating protection unit to protect
the motor via the electric cabinet.
Cooling of motor
The motor is cooled by the pumped medium via the radiator fins on the stator housing. The motor shall be immersed within the medium and the
minimum stop position of the pump shall be no lower than the level shown in the installation dimension diagram.
Mechanic seal
The Burgmann mechanical seals made of wear-resistant friction pair materials with a low friction coefficient are adopted, the rubber parts are
made of oil-resistant NBR, and the metal parts are made of stainless steel.

WQ Series Submersible Sewage Pump


Oil chamber
Besides lubricating the mechanical seals, the oil within the oil chamber can also carry heat away from the bearings. In addition, the oil chamber
also serves another function, ensuring liquid permeation does not occur. The oil chamber is internally fitted with a water leakage probe. Upon
detection of the permeation of medium into the oil chamber, this water leakage probe sounds a warning and stops the pump via the electric cabinet
to alert the operation personnel to conducts checks and provide repairs.
The amount of oil is sufficient to allow oil to escape from the oil filling hole and to ensure a certain volume of air in the oil chamber so that the oil
chamber pressure does not rise significantly after the oil temperature rises, thereby avoiding excessive wear or leakage of the mechanical seal.
Bearing
Originally imported SKF bearings, the upper part of the bearing are deep groove ball bearings or cylindrical roller bearings for radial force. The
lower part of the bearing is used to bear the radial force and the axial force. The pump of each model is different according to the radial force and
axial force. Some are designed as a double row angular contact ball bearing; some are a pair of angular contact ball bearing. All bearings have a
sufficient load margin, with a design life of 100,000 hours.
Sealing of cables and motor
The cables adopt a sewage-resistant heavy-duty rubber jacketed flexible cable, featuring excellent mechanical strength and oil dirt resistance.
The wire cross section and the current carrying capacity of the cables are selected based on the conditions of 40 environmental temperature and
long-time continuous working. Therefore, under the general working conditions, the cables feature sufficient margin of current carrying capacity
and longer life. The cable pressure caps compress tightly the cable seal rings to realize reliable sealing between cables and wiring chamber. The
cables are fixed against pullout. They are affixed with color and digital identifications to make identification and connection of cables easier. The
grounding marking and grounding fasteners are provided in the motor wiring chamber and the electric cabinet. The cables are strictly grounded
to ensure safety and reliability.
During assembly, strict sealing tests are performed for the O-rings, cable seals, and mechanical seals of every pump to ensure the reliable sealing
for the motor chambers, including the wiring chamber.
Protection device
The water pump is fitted with a motor winding overheating protection unit, motor chamber oil-water
probe, and oil chamber water leakage probe. To ensure the safe and reliable running of your pump and
prevent burnout of the motor, the use of our special electric cabinet for submersible sewage pump is
recommended. When the electric cabinet is provided by the user, ensure you contact our electric
cabinet professional team for the relevant electric technical issues, especially regarding the electric
technical issues of the protection devices.
Overheating protection unit
The thermosensitive unit is one electric device whose actions are controlled by temperature, and which
is embedded within the stator winding of the motor, In the event of abnormality, when the winding
temperature reaches the preset value of overheating protection unit, the overheating protection unit
turns on the Overheating indicator lamp via electric cabinet and automatically stops the motor, it
reminds the operation personnel to check and find the cause of the motors overheating.
When the winding temperature drops, the motor will return to its operational state.
Oil-water probe
The oil-water probe is designed for water or oil leakage detection. The water leakage probe in the oil chamber is called an oil
probe for short. If the impellor side mechanical seal is damaged and the water leaking into the oil chamber reaches a certain
level, two electrodes of the water leakage probe are connected to send a warning signal (turn-on of indicator lamp) via electric
cabinet, in order to remind the operation personnel to check the mechanical seal or replacing the oil in the oil chamber.
The water leakage probe in the motor chamber is called a water probe for short. Its installed on the downside of the motor
chamber and in the cavity near the bearing. This cavity has a hole interconnected with the bearing chamber. If the motor side
mechanical seal fails, the oil in the oil chamber flows into this cavity via bearing chamber or the water breached into the motor
flows into this cavity so that two electrodes of the water leakage probe are connected to send a warning signal (turn-on of
indicator lamp) via electric cabinet, this automatically stops the running of the pump, and reminds the operation personnel to
check and repair the pump.
Lifting device
The lifting bracket of the pump is made of stainless steel 304 and is designed with a large space to ease the hookup of the
hook, featuring convenient lifting and excellent durability.

03/04
Specialists in Pumps for
More Than 20 Years.

Materials of Main Pump Parts


No. Name Material

1 Pump body, impellor, pump cover QT500


Enclosure, wiring box cover,
2 connecting seat HT250

3 Shaft 2Cr13

4 Motor insulation 180C insulation grade H

5 Bearing brand SKF

Brand Burgmann

6 Mechanic Motor side friction pair Graphite/silicon carbide


seal
Silicon carbide/silicon carbide or
Pump side friction pair silicon carbide/tungsten carbide
7 O-ring
Nitrile rubber
8 Cable seal ring

Installation Modes
WQ Series submersible sewage pump has auto-coupling installation (Z), fixed base installation (P), fixed base installation (F), mobile hose
installation (R) and mobile pipe installation(Y). All above-mentioned installation modes are simple. The installation modes are described
respectively as below.

Automatic Coupling Mounting (Z) The automatic coupling installation mode utilizes the coupling device to
connect pump and pipeline. With the use of coupling device, the pump
and the water discharge pipeline are independent from each other and
connection by conventional fasteners becomes unnecessary. Therefore,
Electric cabinet its easy to connect and disconnect the pump and water discharge
pipeline. The coupling device is actually really simple and is composed of
a water discharge pipe base, guide rod, guide rod bracket, and coupling
frame. The guide rod is only functional as a guide, not to be subjected to
force, and thus can adopt a common running water tube or steel tube. The
user can prepare it and easily cut to the required length based on the
depth of sewage sump. During the installation, install the water discharge
Cables pipe base, guide rod, and guide rod bracket, install the coupling frame
onto the pump body, lift the pump, pass the guide rod into the
Guide rod semi-circular slot on the coupling frame, and slide the pump along the
guide rod to the bottom so that the coupling frame will buckle tightly the
Discharge pipe
pump body together with the water discharge pipe base. Meanwhile, the
outlet of pump body and the inlet of water discharge pipe base are
automatically aligned and the flange end faces are automatically fitted
tightly. When the repair of pump is required, lift the pump so that the pump
body and the water discharge pipe base are detached. This installation
Working position Level Switch mode is highly convenient for users.
As the coupling device and the pump are relatively independent, if the
replacement of low or high lift pump of same bore diameter is required for
your pump station due to a change of situation, the original coupling
device can still be used.
WQ Series Submersible Sewage Pump
Fixed base installation (P) Fixed base installation (F)

Fix the support base on the foundation and properly connect the water discharge pipe before running the pump.
The base must be fixed by foundation bolts.

Mobile installation (R,Y)

Support the pump by base and connect the discharge hose or pipe to run the pump. This mode is mainly used for emergency use or repair
or construction. If the pipeline for mobile pipe installation has enough stiffness, it s acceptable to hang the pump by pipeline for use.

05/06
Specialists in Pumps for
More Than 20 Years.

Technical Description
Model Description

2445 - 4141A - 300 - Z(YRPF) - K

See descriptions below

Installation mode Z Auto-coupling installation


Y Mobile pipe installation
R Mobile hose installation
P Fixed base installation
F Another fixed base installation

Discharge diameter, mm

Impellor number
Series number
Submersible sewage pump

K: Indicates to connect the motor windings as per delta () winding method in the wiring chamber if the K is omitted. K indicates to directly output
6 lead cables of motor windings.
The last two or three digits in the impellor number indicate the sequence number and the first digit indicates the number of motor poles. For instance:
In the number 4141A, 4 indicates 4-pole motor and 141 is the sequence number, the A or B after the digits indicates the cutting impellor. In the
number 1054, 10 indicates 10-pole motor and 54 is the sequence number.

Rated voltage and rated frequency


The motor is 380V in rated voltage and 50Hz in rated frequency.

Wiring mode
Wiring mode of motor winding wires:
The delta wiring mode () is adopted for 55kW pumps. The wires are already connected as per this wiring mode in the wiring chamber of pump
at the time of delivery. The direct start, auto-coupling voltage-reduction start, or externally connected electric soft starter can be adopted based on
the site condition.
For 75kW pumps, there are two wiring modes for the winding lead wires: Direct connection between 6 power cores in two main cables and 6 lead
wires of motor winding, which is applicable for star-delta (Y-) start or internally connected electric soft starter, and connection of winding as per
delta wiring method () within wiring chamber, which is applicable for auto-coupling voltage-reduction start or externally connected electric soft
starter.

Rotation direction
Observed from the suction port of pump, the impeller is rotating counter-clockwise.

WQ Series Submersible Sewage Pump


Descriptions of performance curve and main parameters
Example I of performance curve and main parameters
Lift
H(m) Performance curve diagram
Boundaries of recommended
50 working scope

40 Main parameters
Drainage port diameter: 250mm
30
Flow passage Rated power Pump
Flow-lift relationship Speed
Pump model dimension of motor weight
20 curve (r/min)
(mm) (kW) (kg)
WQ2368-4149 138 75 1485 1100
Shaft power Rated current Motor power Motor Blockage torque/
Flow-shaft power factor cos efficiency rated torque
relationship curve
P(
a kW) (A) (%)
100 140 0.87 93.8 2.2
80
60

Flow
150 300 450 600 750 900 1050 Q( m / h)
3
0

The solid parts of curve in the above diagram denote the recommended operation range of the pump. The shaft power will rise no further after
reaching a certain value. Generally, the overloading-proof pump has no overload danger, even the occasionally minor overload, is limited. Therefore,
the motor is safe under all flow conditions of the pump. However, its best to use the pump within the recommended scope, as the pump can realize
highest efficiency and sustainability within the recommended scope. However, when the flow is less than the left boundary, the pump efficiency will
be really low causing high radial force and a broken key or shaft. When the flow is higher than the right boundary, the pump will create vibration and
noise problems.
Please refer to Performance Specification of WQ Series Submersible Sewage Pump for the maximum sizes of solid contents. For the
WQ2368-4149 pump shown in the figure, the diameter of solid contents shall not exceed 100mm.
The pump weight excludes accessories (such as coupling device, suction elbow, base, elbow connector, and hose elbow connector) required for
diversified installation modes.

Example II of performance curve and main parameters

H( m) Performance curve diagram Main parameters


40 400mm Drainage port diameter: 400mm

35 Flow passage Rated


1
dimension power Speed Pump
No. Pump model of motor (r/min) weight
30 (mm) (kW) (kg)
2
1 WQ2590-6107 190 280 990 5050
25
2 WQ2590-6106 190 250 990 4860
3
20 3 WQ2590-6105 190 220 990 4670
P(kW) Motor Blockage
15 a Rated current Motor power
1 No. efficiency torque/
2 300 (A) factor cos
(%) rated torque
250
1 507 0.88 95 . 2 1.5
200
150 2 453 0 . 88 95 . 1 1 . 45
3
100 1 . 52
3 398 0 . 88 95 . 1
0 500 1000 15002000 2500 3000 3500 4000
Q(m /h)
3

On this type of diagram, the line 1 denotes the original pumps and the lines 2 and 3 denote the pumps with lathed small impellors. The pumps with
lathed small impellors are more applicable for certain working needs and can reduce the risk of motor overload.

07/08
Specialists in Pumps for
More Than 20 Years.

Description of installation dimension diagram

1. All guide rod brackets can be fixed by M16150 type I steel expansion bolts. The expansion bolts are easily available and can be
prepared by clients or procured from our company.
Function of rubber block on guide rod bracket: Tighten the adjustment screw on the rubber block to expand the rubber block tightly in the
bore of guide rod and stabilize the guide rod.
2. Calculate the length of the guide rod as per the sump depth indicated on the diagram. Refer to attached Table 1 for the related
information of guide rod.
3. For the coupling installation of pump without flared water inlet pipe, fabricate the bottom of the sump to a flat plane so that the height of
the water discharge pipe seat can guarantee enough height between the suction port of pump and the sump bottom to provide good
,
suction conditions for the pump. Therefore, it s unnecessary to fabricate a boss for the water discharge pipe seat, which can relieve
construction troubles.
For the coupling installation of pump with flared water inlet pipe, to guarantee enough height between flared pipe and sump bottom,
fabricate a boss of a certain height for the water discharge pipe seat. The Installation Dimensional Table gives the minimum height of the
boss.

WQ Series Submersible Sewage Pump


4. denotes the minimum liquid level required for the running of pump. The water level shall be higher than the minimum level during running
of pump. If possible, completely immerse the pump, in order to provide more sufficient cooling for the motor. The minimum water level can be
controlled by the float switch. Our special electric cabinets of submersible sewage pumps are of level control type and are fitted with float
switches.
5. For pumps of mobile installation mode, the hose elbow connectors or the elbow connectors are provided by our company. For mobile hose
installation mode, please refer to the attached Table 2 for the inside diameters of hoses applicable for diversified diameters of pumps.
6. For pumps of the same mode, the base is the same for fixed base installation and mobile installation, the shape and size of the base is
shown in view M
7. GB/T17241.6-2008/XG1-2011standard
The flange size indicates the discharge flange of pump, the flange of water discharge pipe seat, and the suction flange of suction elbow. The
flange dimensions follow standard requirements: GB/T17241.6-2008/XG1-2011.

Attached Table 1 Specifications and Dimensions of Pump Guide Rods

Discharge diameter Specification of guide rod Guide rod reference length =


of pump Running water tube/seamless (Sump depth - L)15mm
(mm) steel tube Size L is shown below

Attached Table 2 Pump Hoses


Discharge diameter
of pump (mm)
Specification of fitted hose
elbow connector
Inside diameter of fitted
hose (mm)

09/10
Specialists in Pumps for
More Than 20 Years.

Attached Table 3 Foundation Bolts of Water Discharge Pipe Seat for


Auto-coupling Installation Mode of Pump

Foundation bolt (GB/T799-1988)


Discharge
diameter Reference size of
of pump reserved hole
(mm) Specification Quantity
Length Width Depth
(mm)
50
M16 220 80 80 270
65

80

100 M20 300


4 100 100 350
150

200 M24 300

250

300
M30 400 160 160 450
350

400
6
500
M36 500 160 160 550
600

Attached Table 4 Foundation Bolts for Fixed Base Installation Mode of Pump

Foundation bolt (GB/T799-1988)


Base hole Reference size of
diameter reserved hole
Specification
Length Width Depth
(mm)
1820 M16220 8080270

25 26 M20300
100100350
30 M24300

36 40 M30400 130130450

46 48 M36500 160160550

Attached Table 4. Foundation Bolts for Fixed Foot Mounting and Fixed Dry Mounting of WQ2000 Pump

WQ Series Submersible Sewage Pump


Terminal Box and Wiring Conduit of (Level) Float Switch
for Special Electric Cabinet of Submersible Sewage Pump
Special Electric Cabinet of Submersible Sewage Pump

The submersible sewage pump is internally fitted with diversified types of motor protection devices. The electric cabinet of submersible
sewage pump must be compatible with these protection devices and must be fitted with a float switch to control the start/stop of pump by
sewage level. Therefore, the electric cabinet of submersible sewage pump features unique characteristics. Our special electric cabinet of
submersible sewage pump is compatible with the protection devices of the pump. Its fitted with a certain number of float switches depending
on the users chosen control mode and incorporates the protective functions against main circuit short-circuit, overload, and phase loss. The
electric cabinet for >15kW pumps is also fitted with auto-coupling voltage-reduction start or electric soft start function. During the normal
functioning of the electric cabinet with main/standby pump control mode, the alternating modes for main/standby pumps include manual
alternating, periodic alternating (for continuous running applications), and automatic alternating (for intermittent running applications. In event
of malfunction, the electric cabinet with main/standby pump control mode embodies the function of automatically stopping the malfunctioned
pump and automatically starting the standby pump (automatic start of standby pump). If the user adopts our electric cabinet but disconnects
the pump protection devices, or the electric cabinet prepared by the user is incompatible with the pump protection devices, or the protection
function against main circuit short-circuit, overload, and phase loss is not set, it will certainly lead to no alarm or the pump stopping in the
event of malfunction, which will finally lead to failure of users to check and repair, causing motor burnout. Therefore, upon procurement of
submersible sewage pump, please procure the special electric cabinet of submersible sewage pump at the same time whenever possible.

The above section describes the special electric cabinet of submersible sewage pump. Please refer to the brochure or manual of our electric
cabinet for details.

(Level) float switch

Schematic diagram of (level) float switch

For water supply For water discharge

Cable
Stop of pump
Floater Start of
pump

Counterweight
Start of pump Stop of
pump

The minimum liquid level is indicated on the brochure and manual of submersible sewage pump. denotes the level at which the stator of
the motor is half immersed by the medium.
The level float switch functions only when the electric cabinet is placed in automatic mode.
Wiring and setup of level float switch: The cable of level float switch contains three cores, namely black, brown, and blue. When the floater
raises, the internal contact of the floater connects the black and brown cores and disconnects the black and blue cores. When the floater
drops, the internal contact of the floater connects the black and blue cores and disconnects the black and brown cores. When the floater is
in the middle position, the internal switch is in an original holding position. The internal switch acts only when the floater is at the raised or
dropped position as shown in the figure. For water discharge applications, connect the black and brown cores into the electric cabinet and
wrap and insulate the blue core. For water supply applications, connect the black and blue cores into the electric cabinet and wrap and
insulate the brown core. If one float switch is used to control the start and stop levels of the pump, adjust the location of the counterweight on
the cable to determine the difference of liquid level for the start and stop of the water pump. Therefore, based on the working principle, one
float switch can achieve the control on the start and stop of pump for one group of upper and lower liquid levels. However, for a large
difference between liquid levels, the length of floater swing arm is increased accordingly and thus the control accuracy of the liquid level is
impaired due to the dead weight of the cable segment between the counterweight and floater. Therefore, our special electric cabinet for
submersible sewage pump is configured in such manner that two float switches are used to control the start and stop levels respectively for
main pump or primary pump and one float switch is used to control both start and stop levels of the pump for the small-diameter pump or
standby pump started at ultimate upper level. The user may order the float switches from us for additional float switches or the electric cabinet
other than our special electric cabinet for submersible sewage pump.

11/12
Specialists in Pumps for
More Than 20 Years.

Black; Brown; Blue

Brown
Black
Upper position for switch changeover
Blue

On-off State Remaining Position

Black Brown Remove small ring


Lower position for switch changeover

Blue

Black, brown, and blue


Counterweight

Wiring direction
Upper level

Cable

Level difference
Counterweight (swing of lower cable)
Attach small ring to
required fixing position
Le
Lo ngt of counterweight
we h o
rC f
ab Lower level
le
Floater

Terminal box and wire conduit


The terminal box can be set if the electric cabinet is far from the pump house. The terminal box is one optional part.
Electric cabinet

Terminal box

Wire conduit

Note: The inside diameter of wire conduits shall be consistent


with the outside diameter of cables.

This diagram is only for schematic purposes and doesnt denote design specification. The issues regarding the design and safety of the pump
house shall be handled as per relevant standards and specifications.
When the setup of wire conduits (to be prepared by the user) is required, determine the inside diameter of wire conduits as per the outside
diameter of cables. If our special cables for submersible sewage pump are used between the terminal box and electric cabinet, please
contact the Technical Department of Shanghai Kaiquan (Hefei) Plant to determine the outside diameters of cables.

WQ Series Submersible Sewage Pump


Ordering Description
To make your procured pump more suitable, customers are welcome to consult technical issues with our Technical Department.
Please indicate the series number, impellor number, flow passage part material, installation mode, and discharge port diameter at the time
of ordering. If the star-delta (Y-) start or internally connected electric soft starter is adopted, please add -K to the end of pump model
and indicate with K motor on the pump order. If the auto-coupling voltage-reduction start or externally connected electric soft starter is
adopted and the pump is fitted with motor of internal delta wiring mode (namely the motor winding is connected as per delta wiring mode
in the wiring chamber), do not add K to the pump model.
The installation mode of water pump shall follow the installation dimension diagram on the brochure.
Thanks to the excellent design of the guide rod bracket in the coupling device, it s only necessary to use a common running water tube or
steel tube as the guide rod. The specification and length calculation method for the running water tube or steel tube used as guide rod is
provided on the brochure. The user only needs to procure a running water tube or steel tube and cut it to the required length. Therefore, no
guide rod is included in the coupling device.
No motor cooling system is fitted for this series pump. Therefore, the cooling sleeve can t be additionally installed.
The standard configuration includes 10m motor cables. The user shall specify at the time of ordering if the cables of other length are
required.
The supply part package is supplied as per the user s selected installation mode.
Optional parts and spare parts are ordered separately by the user.
For mobile pipe installation mode (Y), an elbow connector is supplied for every pump package. For mobile hose installation mode (R), a
hose elbow connector is supplied for every pump package. If more than one elbow connector or hose elbow connector is required for the
pump of mobile installation mode, please order separately.
The elbow connectors are in bore diameter of 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, and 600.
The hose elbow connectors are in bore diameter of 50 (For 64 hose), 5065 (For 76 hose), 65 (For 76 hose), 80 (For 89 hose), 100 (For
102 hose), and 150 (For 152 hose).
The optional taper pipes are in two-sided bore diameters of 5065, 5080, 6580, 80100, 100150, 150200, 200250, 250300,
300350, 350400, 400450, 450500, and 500600. The taper pipe installed on the discharge pipeline shall be only used for expanded
application, instead of contracted application.
While connecting the taper pipe and elbow connector on the discharge pipeline, the bore diameter of the elbow connector shall be
consistent with that of the large end of the taper pipe, namely the principle of expanding before turning shall be followed, in which case
the pipe loss is less than that of the turning before expanding .
For the pump of coupling installation mode, if the bore diameter of the discharge pipeline is larger than that of the pump, a taper pipe can
be additionally installed on the water discharge pipe seat and the small end bore diameter of the taper pipe shall be consistent with the
bore diameter of the water discharge pipe seat (namely the bore diameter of pump).
Refer to the Descriptions of Accessories at the end of brochure for the specifications, nominal pressures, and dimensions of elbow
connectors; hose elbow connectors, and taper pipes.

13/14
Specialists in Pumps for
More Than 20 Years.

Supply Checklist

Installation Modes

Wet installation mode

Supply Scope
Auto-coupling Fixed base Mobile hose Mobile pipe single
installation installation installation installation pump
Z P R Y

Main pump
Complete package

Automatic coupling device


Base

Elbow connector + accessory

Hose elbow connectors + accessory

Elbow connector + accessory

Hose elbow connectors + accessory

Guide rod
Expansion bolts
Optional parts

Foundation bolt

Stainless steel rope and rope


clamp for lifting of pump

Steel chain and shackles for


lifting of pump
Taper pipe
Pairing flange
Impellor
Bearings

Spare parts

Mechanic seal

O-ring
Seal ring

WQ Series Submersible Sewage Pump


Spectrum Diagram and Description of WQ Series
Submersible Sewage Pump

W
W

Q2
Q2

44
29

5-
0- 2

41

W
24

Q2
41
13

45

-3

59
-4

W
1-1

0-6
1

Q2
0-
41
00

11
16

59
A-
W

4-3
-30

0-6
0
3

W
Q

00

50 W 20
11
22

Q2
-1

-25 Q
3-3
90

5
2
W

0 25
20
-4

50
Q
17

-6

-
25

2
5-

10

90
W
W

20
20 WQ

-6
Q2
Q

3-

10
-
24
W
0- 2 2 9

61

7-
52
Q

00
45 5- 4

40
55 0-

02
24

0-
0
W

- 4 14

28
-6

20
4

-4
14 0
Q

0 WQ 259
10
24

00
0

0
-3 30 0-1

1
4
4

-
00 0

-4
5

18

W
16

25

W
-4

A-

00

90 - 611
1
8-

Q
13

60 32

W
25

-6

23
-1

W
9-

11
W

0
0-

60
-1

25

Q2 6
30

9-

8-
Q2 5-40 00-
55

90 0-6
Q

36
50

41
25

-6

W W
59 0 - 2 0

8-

8-
W

0-
2

Q2 Q 21
0

0- 22 0
Q

41
50

28

23
10

25

29
61 0

-3
12

20
W

0-

68
0
2

0-
Q

6
0

17

0
25

1 2 - 30
-4
-4
-6
25

41 W 0-
-5
12

0
2

Q2
W

12 0- 90
0-

00
5-

0A
Q

90
6

W 590
W

29
40

-2
24

10

-2

-3 W
Q2 -8
Q2 259

50
0-

0-
45

00
2

Q2
18
-4

WQ 41
0

-4
-6

59 16

-7
W

44
00

1
16

5 W
22 8- 5 5-
Q
-1

0- 8-

Q2
W
5-

9 61
3
60

0-4
81 60
40

Q 590

WQ 00 44 64
W

W
1
2

-4
0

5
69 0-

17 -5 Q
Q

0-

-
59 -81

22 61 00
13

24
W

- 5
2

9 3 -1
81 6-60 0-2

-6 28

6
0

4
2

0-4 00
Q

WQ 3- 10
W

5-
-8

00 0

-
67

1 61 40 W
25

4
Q

16 5-60

22 16 5 W 62 0- Q
-3
-6

Q2
25

90
90

-3 - 9 W 25
15

-41 00 3 4 0
00 20
20

68
6
-8

00 Q 20
15 - WQ
Dotted part of the selection of WQ / E 3 -61 25
-2

-
-8

16

-30 7 75 -8
0

23 61
50
16

2
-2

16
4-

0-3 68 -35 0-
small submersible sewage pump -61
3-

60

WQ 0 0-5 W 81 2-
50

236 60 50
00

W 61
0-

-35 5 Q
WQ 8-6 25
0-

Q2 0-
18

159 0-4 20 -5 13
16

236 -35 52 00
5

8 0-3 5 W -8
2
0

WQ -61 7 Q2 0- 16 -1
WQ 229 58-3 W 36 8 15 0 - 1
50 0
W

229 0-6 50-3 Q2 8 9 0


Q

W -8 -5 -
W

0-6 157 0 36 90
25

Q2 15 00
Q

WQ 156 -30 8
20
25

-7
W

W
229 -30 0-2 W 36 -8 8-
-1

5
Q

20

0-1 Q
0-6 2 Q 8 1 4
05

2
25

-81 57 00
-1

155 8.5 WQ 23 52
20

7-
05

-30 68 56 -4 -5 0-
60
-1

23 00 5 10
6-

0-1 WQ -40
05

-8
0-

68
60

54
5
0-3 -45
13

-81 15
5-

236
0-

-6
60

54 5- 00
11

WQ 8-8 7
0-

-35 40 -7
0

153
90

236 0 - 0 5
8-8 -3 50-1 2 2 -3
152 0
-35 8.5
0-1
5

Description of spectrum diagram:


1. The spectrum diagram lists the basic range for most models, based on which the model can be preliminarily selected. Please refer to
the Performance Curve Diagram and Main Parameters below for detailed parameters of the water pump.
2. In the diagram, the rated power of pump motor is indicated behind the pump model.
3. For the WQ/E series in the diagram, please refer to the brochure WQ/E Series Small-Sized Submersible Sewage Pump for details.

15/16
Specialists in Pumps for
More Than 20 Years.

Performance Specification of WQ Series Submersible


Sewage Pump
Maximum
Bore Design Design Pump Installed flow-
Speed through Weight
diameter flow lift efficiency power particle
No. Specification and model size

mm m 3/h m r/min % kW mm kg
1 WQ2210-2112-65 50 46 2940 60 15 30 136
65
2 WQ2210-2111-65 40 40 2940 60 11 30 128
3 WQ2210-2116-80 80 34 2935 61 15 36 138
80
4 WQ2210-2115-80 70 30 2935 61 11 36 128
5 WQ2260-2124-100 130 33 2940 61 22 44 236
100
6 WQ2260-2123-100 120 31 2940 61 18.5 44 222
7 WQ2260-4138-150 200 16 1460 74 15 60 242
150
8 WQ2260-4125-150 160 15 1460 74 11 60 226
9 WQ2260-4131-200 300 18 1470 85 22 70 306
10 WQ2260-4130-200 300 16 1470 85 18.5 70 294
200
11 WQ2260-4129-200 300 13 1460 82 15 70 274
12 WQ2260-4128-200 280 11 1460 83 11 70 258
13 WQ2260-4157-200 500 10.5 1470 80 22 80 298
14 WQ2260-4156-200 500 8 1470 79 18.5 80 286
200
15 WQ2260-4155-200 400 8 1460 78 15 80 270
16 WQ2260-4154-200 400 6.5 1460 78 11 80 254
17 WQ2290-2125-100 120 50 2945 65 30 40 400
100
18 WQ2290-2126-100 135 56 2945 65 37 40 420
19 WQ2290-2131-100 165 39 2945 71 30 40 410
100
20 WQ2290-2132-100 185 42 2945 71 37 40 430
21 WQ2290-4135-150 160 41 1470 72 30 62 550
22 WQ2290-4135A-150 150 160 40 1470 70 30 62 545
23 WQ2290-4135B-150 160 38 1470 70 30 62 540
24 WQ2290-4134A-150 250 26 1470 75 30 60 565
150
25 WQ2290-4134-150 250 28 1475 75 30 60 570
26 WQ2290-4170-150 220 45 1475 70 45 60 650
150
27 WQ2290-4171-150 245 48 1475 75 55 60 700
28 WQ2290-4172A-200 330 20 1470 80 30 90 510
29 WQ2290-4172-200 360 22 1470 80 30 90 515
30 WQ2290-4173-200 200 400 24 1470 79 37 90 570
31 WQ2290-4174-200 390 28.5 1470 79 45 90 680
32 WQ2290-4175-200 440 31 1470 79 55 90 745
33 WQ2290-4109-250 250 650 12 1470 79 30 100 620

WQ Series Submersible Sewage Pump


Maximum
Bore Design Design Pump Installed flow-
Speed through Weight
diameter flow lift efficiency power particle
No. Specification and model size

mm m 3/h m r/min % kW mm kg
34 WQ2290-4110-250 650 15 1470 79 37 100 640
35 WQ2290-4112-250 250 650 18 1470 79 45 100 685
36 WQ2290-4168-250 650 22 1470 79 55 100 750
37 WQ2290-4115-300 750 10 1470 80 30 120 850
38 WQ2290-4116-300 800 13 1470 80 37 120 900
300
39 WQ2290-4117-300 720 16 1470 79 45 120 980
40 WQ2290-4118-300 720 19 1470 79 55 120 1080
41 WQ2290-6155-300 650 6.5 980 82 15 90 765
42 WQ2290-6156-300 300 750 7 980 81 18.5 90 780
43 WQ2290-6157-300 780 7.5 980 80 22 90 800
44 WQ2368-4165-150 295 56 1485 75 75 60 1010
150
45 WQ2368-4166-150 330 60 1485 75 90 60 1100
46 WQ2368-4145-200 520 36 1485 75 75 80 1080
200
47 WQ2368-4146-200 570 39 1485 75 90 80 1170
48 WQ2368-4149-250 650 29.5 1485 78 75 100 1110
250
49 WQ2368-4150-250 720 32 1485 78 90 100 1230
50 WQ2368-4120A-300 850 22 1485 81 75 120 1500
300
51 WQ2368-4120-300 950 24 1485 81 90 120 1650
52 WQ2368-4121-300 300 1100 21.5 1485 81 90 120 1657
53 WQ2368-6158-350 900 9 980 80 30 91 1150
54 WQ2368-6159-350 1000 10 980 81 37 91 1180
350
55 WQ2368-6160-350 1300 9.5 980 81 45 91 1500
56 WQ2368-6161-350 1400 10.5 980 81 55 91 1550
57 WQ2368-8152-350 900 4 730 80 15 70 1300
58 WQ2368-8153-350 350 1000 4.5 730 80 18.5 70 1350
59 WQ2368-8154-350 1150 5 730 80 22 70 1400
60 WQ2368-8155-400 1350 6 735 81 30 80 1500
61 WQ2368-8156-400 1600 6.5 735 81 37 80 1560
400
62 WQ2368-8157-400 1700 7 735 82 45 80 1640
63 WQ2368-8158-400 1800 8 735 82 55 80 1670
64 WQ2445-4147-200 480 60 1485 75 132 80 1700
200
65 WQ2445-4148-200 520 67 1485 75 160 80 1600
66 WQ2445-4151A-250 250 575 39 1485 81 110 100 1830

17/18
Specialists in Pumps for
More Than 20 Years.

Maximum
Bore Design Design Pump Installed flow-
Speed through Weight
diameter flow lift efficiency power particle
No. Specification and model size

mm m 3/h m r/min % kW mm kg
67 WQ2445-4151-250 700 39.5 1485 81 110 100 1840
68 WQ2445-4152A-250 620 46 1485 81 110 100 1850
250
69 WQ2445-4152-250 770 43 1485 81 132 100 2010
70 WQ2445-4153-250 880 46 1485 81 160 100 2250
71 WQ2445-4139-300 1200 24 1485 81 110 120 2120
72 WQ2445-4140A-300 300 1200 27 1485 81 132 120 2320
73 WQ2445-4140-300 1300 30 1485 81 160 120 2520
74 WQ2445-4141A-300 1000 35 1485 81 132 120 2300
300
75 WQ2445-4141-300 1050 41 1485 81 160 120 2520
76 WQ2445-6121-350 1250 15 990 81 75 105 2000
77 WQ2445-6122-350 1400 15 990 81 90 105 2160
350
78 WQ2445-6123-350 1800 17 990 81 110 105 2320
79 WQ2445-6124-350 1800 20 990 83 132 105 2500
80 WQ2445-6162-400 1650 13 990 82 75 110 2100
81 WQ2445-6163-400 1800 13.5 990 82 90 110 2230
400
82 WQ2445-6164-400 2100 14.5 990 82 110 110 2380
83 WQ2445-6165-400 2400 15 990 83 132 110 2540
84 WQ2520-4160-300 1200 37 1485 81 185 80 2000
85 WQ2520-4161-300 1400 37 1485 82 200 80 2050
86 WQ2520-4162-300 300 1400 42 1485 82 220 80 2150
87 WQ2520-4163-300 1400 49 1485 84 250 80 2300
88 WQ2520-4164-300 1400 52 1485 84 280 80 2500
89 WQ2520-6101-400 1600 25 990 81 160 130 2360
90 WQ2520-6102-400 400 1800 28 990 81 185 130 2500
91 WQ2520-6103-400 1800 31 990 81 200 130 2600
92 WQ2520-6104-400 2400 18 990 81 160 130 2580
93 WQ2520-6125-400 400 2400 20 990 81 185 130 2800
94 WQ2520-6126-400 2500 22 990 81 200 130 2950
95 WQ2520-6108-500 3000 13 990 82 160 130 3605
96 WQ2520-6109-500 500 3000 17 990 82 185 130 3810
97 WQ2520-6110-500 3000 18.5 990 82 200 130 3980
98 WQ2520-8159-500 2300 9 735 81 75 140 2890
99 WQ2520-8160-500 500 2300 10 735 81 90 140 3010
100 WQ2520-8161-500 2900 10 735 81 110 140 3220

WQ Series Submersible Sewage Pump


Maximum
Bore Design Design Pump Installed flow-
Speed through Weight
diameter flow lift efficiency power particle
No. Specification and model size

mm m 3/h m r/min % kW mm kg
101 WQ2520-8162-500 3000 11 745 81 132 140 3450
500
102 WQ2520-8163-500 3400 12.5 745 81 160 140 3630
103 WQ2520-1054-600 3000 7 590 82 75 160 3800
104 WQ2520-1055-600 3200 7.5 590 82 90 160 4000
600
105 WQ2520-1056-600 3600 8 590 82 110 160 4250
106 WQ2520-1057-600 3800 9 590 82 132 160 4500
107 WQ2590-6113-350 1600 38 990 82 220 140 4630
350
108 WQ2590-6114-350 1600 40 990 82 250 140 4850
109 WQ2590-6105-400 2500 23 990 82 220 150 4670
110 WQ2590-6106-400 400 2500 27 990 82 250 150 4860
111 WQ2590-6107-400 2500 30 990 82 280 150 5050
112 WQ2590-6117-500 3000 20 990 82 220 150 4860
113 WQ2590-6118-500 500 3000 23.5 990 82 250 150 5170
114 WQ2590-6119-500 3000 26 990 82 280 150 5480
115 WQ2590-8164-600 3800 12.5 745 82 185 150 4850
116 WQ2590-8165-600 4000 13.5 745 82 200 150 5000
117 WQ2590-8166-600 4300 14 745 82 220 150 5200
600
118 WQ2590-8167-600 4600 15 745 82 250 150 5500
119 WQ2590-8168-600 4800 16 745 82 280 150 5800
120 WQ2590-8169-600 5000 16 745 82 315 150 6100
121 WQ2590-1058-700 5000 8 590 82 160 170 6200
700
122 WQ2590-1059-700 5250 10 590 82 185 170 6500
123 WQ2590-1250-700 5400 10 495 85 185 176 6800
124 WQ2590-1251-700 700 5700 10 495 85 200 176 7100
125 WQ2590-1252-700 6000 10.5 495 85 220 176 7400
126 WQ2670-1253-800 6500 11 495 85 250 200 8000
127 WQ2670-1254-800 800 6900 12 495 85 280 200 8400
128 WQ2670-1255-800 7300 12 495 85 315 200 8800
129 WQ2740-6170-600 600 3600 30 980 82 450 100 6300
130 WQ2850-8175-600 600 4200 35 745 82 580 100 9800
131 WQ2850-8170-900 7000 15 745 82 450 200 9500
132 WQ2850-8171-900 900 7500 16.5 745 82 500 200 9500
133 WQ2850-8172-900 8000 18 745 82 560 200 9500
134 WQ2850-1062-1000 1000 9500 15 590 82 560 250 10000

19/20
Specialists in Pumps for
More Than 20 Years.

WQ series submersible sewage pump performance curve, main parameters,


installation dimensions
Main Parameters
H(m) Performance Curve Discharge Diameter 65mm
70

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
60 1 (mm) (kW) (r/min) (kg)

50 1 WQ2210-2112 square 8 15 2940 136


2 WQ2210-2111 square 38 11 2940 128
40

number
Rated current Motor Power Motor Stall torque /

Serial
2 Factor efficiency Rated torque
30 (A) c os (%)
1 29 0.90 88.8 2.4
20
Pa(kW) 22 0.89 87.6 2.3
1 2
15 Intermediate
Flow-head High lift point point High flow point
10
2 5 1 30-51 50-46 70-41
m 3/h-m
2 25-43 40-40 60-34
3
0 10 20 30 40 50 60 70 80 Q (m /h)

Installation Dimensional Drawing


Z Automatic coupling installation
950650

60 A B to
579 28
108 415

40
18
927

250
310
578
25 25
400

215
63
100

M to
A to 4-20
950 Flange dimensions
pool side 4-20 65
350350
154

420420

130
160
173 154

173
650
370
320

4-13.5

Flange press GB/T17241.6 PN6 standard


240 164
200
320 pool mouth
370
804

R Hose mobile installation Y Hard tube mobile installation P Fixed base mounting
M M M

74
712
909

909

560
357

560

560
327
197

197

197

617 660

WQ Series Submersible Sewage Pump


Performance Curve Main Parameters
H(m) Discharge Diameter 80mm
60

number
Flow Channel Motor Rated Rotating pump

Serial
50 Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)

40 1 WQ2210-2116 square 45 15 2935 138


1
2 WQ2210-2115 square 45 11 2935 128
30

number
2 Rated current Motor Power Motor Stall torque /

Serial
Factor efficiency Rated torque
20 (A) c os (%)

10 1 29 0.90 88.8 2.4


Pa(kW) 2 22 0.89 87.6 2.3
20
1 High lift point Intermediate High flow point
15 Flow-head point
10 1 45-38 80-34 120-23
3
2 5 m /h-m
2 40-33 70-30 110-20
3
0 20 40 60 80 100 120 Q (m /h)

Installation Dimensional Drawing


950650
Z Automatic coupling installation
B

60 A B to
587 28
108 430

40
18
1040

250
310
691
25 25
480

325

M to
176

A to
950
Flange dimensions 4-20

pool side 4-24 80


350350
150

420420

150
190
178 150

178
650
430
360

4-17.5

Flange press GB/T17241.6 PN6 standard


250 157
200
350 pool mouth
420
822

R Hose mobile installation Y Hard tube mobile installation P Fixed base mounting
M M M

86
715
924

924

575
399

575

575
364
209

209

209

638 710

21/22
Specialists in Pumps for
More Than 20 Years.

Main Parameters
Performance Curve
H(m) Discharge Diameter 100mm
60

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
50 (mm) (kW) (r/min) (kg)

1 WQ2260-2124 square 55 22 2940 236


40 1
2 WQ2260-2123 square 55 18.5 2940 222
30

number
Rated current Motor Power Motor Stall torque /

Serial
2 Factor efficiency Rated torque
20 (A) c os (%)

Pa(kW) 1 41 0.90 90.5 2.0


10 1
25 2 35 0.91 90 2.7
20 High lift point Intermediate High flow point
Flow-head point
15
2 1
10 80-39 130-33 200-20
m3/h-m
5 2 75-35 120-31 160-22
3
0 30 60 90 120 150 180 210 Q (m /h)

Installation Dimensional Drawing


950650
Z Automatic coupling installation
B

60 A B to
667 28
128 485

40
18
1148

280
340
713
25 25
480

300
213

M to
A to
950
Flange dimensions 4-25

pool side 4-24 100


520520
600600
170

170
270

210
202 170

202
650
430
360

4-17.5

Flange press GB/T17241.6 PN6 standard


300 182
233
350 pool mouth
420
936

R Hose mobile installation Y Hard tube mobile installation P Fixed base mounting
M M M

100
848
1126

1126

691
518

691

691
438
278

278

278

810 865

WQ Series Submersible Sewage Pump


Performance Curve
Main Parameters
H(m) Discharge Diameter 150mm

number
24 Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
20 1 1 WQ2260-4138 oval 7779 15 1460 242
16 2 WQ2260-4125 oval 7779 11 1460 226

number
2 Rated current Motor Power Motor
12 Stall torque /

Serial
Factor efficiency Rated torque
(A) c os (%)
8 Pa(kW)
1 30 0.85 89.4 2.6
1 15
2 23 0.85 88 2.4
10 Intermediate
Flow-head High lift point point High flow point
2
5 1 80-21 200-16 300-9
m 3/h-m
2 80-18 160-15 260-10
0 40 80 120 160 200 240 280 320
Q (m 3/h)

Installation Dimensional Drawing


1000700
Z Automatic coupling installation
B

60 A B to
776 28
128 550

40
18
1078

320
380
678
25 25
480

300

M to
116
100

A to 4-25
1000
Flange dimensions
pool side 4-24 150
520520
600600
199

225
270

265
253 199

253
700
430
360

8-17.5

Flange press GB/T17241.6 PN6 standard


365 226
253
350 pool mouth
420
1065

R Hose mobile installation Y Hard tube mobile installation P Fixed base mounting
M M M

150
778
1072

1072

672
614

672

672
514
294

294

294

960 1018

23/ 24
Specialists in Pumps for
More Than 20 Years.

Performance Curve
Main Parameters
H(m) Discharge Diameter 200mm
25

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
20 (mm) (kW) (r/min) (kg)
1
15 1 WQ2260-4129 oval 8593 15 1460 274
2 WQ2260-4128 oval 8593 11 1460 258
10

number
2 Rated current Motor Power Motor Stall torque /

Serial
Factor efficiency Rated torque
5 (A) c os (%)

Pa (kW) 1 30 0.85 89.4 2.6


0
1 0.85
15 2 23 88 2.4
High lift point Intermediate High flow point
Flow-head point
10
2 1 170-17 300-13 400-9
m 3/h-m
5 2 150-15 280-11 380-6
3
0 60 120 180 240 300 360 420 Q (m /h)

Installation Dimensional Drawing


Z Automatic coupling installation
12 0 0900

72 A B to
885 28
274 612

40
18
1168

370
430
733
35 25
615

375
173
100

A to
1200
Flange dimensions

pool side 4-33 200


280
320
306 236
900
650
550

8-17.5

Flange press GB/T17241.6 PN6 standard


454
560 pool mouth
660
1389

P Fixed base mounting M to


M
4-25
520520
600600
236

270
793

306
680
322

420 273

WQ Series Submersible Sewage Pump


Performance Curve Main Parameters
H(m) Discharge Diameter 200mm
30

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
25 (r/min) (kg)
(mm) (kW)

20 1 1 WQ2260-4131 oval 8593 22 1470 306


2 WQ2260-4130 oval 8593 18.5 1470 294
15
2

number
Rated current Motor Power Motor Stall torque /

Serial
Factor efficiency Rated torque
10 (A) c os (%)

Pa(kW) 1 40 0.87 91.2 2.2


25 2 36 0.87 90.7 2.2
1
20 Intermediate
Flow-head High lift point point High flow point
15
2
10 1 180-20 300-18 420-13
m 3/h-m
2 180-18.5 300-16 400-12
3
0 60 120 180 240 300 360 420 Q (m /h)

Installation Dimensional Drawing


1200900
Z Automatic coupling installation
B

72 A B to
885 28
274 612

40
18
1238

370
430
803
35 25
615

375
173
100

A to
Flange dimensions
1200
pool side 4-33 200
280
320
306 236
900
650
550

8-17.5

Flange press GB/T17241.6 PN6 standard


454
560 pool mouth
660
1389

P Fixed base mounting M to


M
4-25
520520
600600
236

270
863

306
750
322

420 273

25/26
Specialists in Pumps for
More Than 20 Years.

Performance Curve
Main Parameters
H(m)
Discharge Diameter 200mm
12

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
10 (mm) (kW) (r/min) (kg)
1
1 WQ2260-4155 100 15 1460 270
8
2 2 WQ2260-4154 100 11 1460 254
6

number
Rated current Motor Power Motor Stall torque /

Serial
Factor efficiency Rated torque
4 P a (kW) (A) c os (%)
1 16 1 30 0.85 89.4 2.6
14
2 23 0.85 88 2.4
12
10 Flow-head High lift point Intermediate
point High flow point
2 8 1 3
280-10 400-8 500-6
m /h-m
2 250-9 400-6. 5 440-5.5
200 280 360 440 520 Q(m 3/h)

Installation Dimensional Drawing


1200900 Z Automatic coupling installation
B

72 A B to
896 28
274 612

40
18
1155

370
430
720
35 25
615

375
170
100

A to
1200 Flange dimensions
pool side 4-33 200
280
320
324 242
900
650
550

8-17.5

Flange press GB/T17241.6 PN6 standard


454
560 pool mouth
660
1400

P Fixed base mounting M to


M
4-25
520520
600600
242

270
780

324
670
325

420 284

WQ Series Submersible Sewage Pump


Performance Curve Main Parameters
H(m) Discharge Diameter 200mm

number
14 Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
12
1 1 WQ2260-4157 100 22 1470 298
10
2 WQ2260-4156 100 18.5 1470 286

number
8 2 Rated current Motor Power Motor Stall torque /

Serial
Factor efficiency Rated torque
(A) c os (%)
6 P a ( kW)
1 42 0.87 91.2 2.2
1 24
20 2 36 0.87 90.7 2.2
16 Flow-head High lift point Intermediate
point High flow point
2 12
1 350-12 500-10.5 600-8
m 3/h-m
280 2 350-1 500-8 550-7
360 440 520 600 Q( m 3/ h)

Installation Dimensional Drawing


Z Automatic coupling installation
1200900

72 A B to
896 28
274 612

40
18
1225

370
430
790
35 25
615

375
170
100

A to
1200 Flange dimensions
pool side 4-33 200
280
320
324 242
900
650
550

8-17.5

Flange press GB/T17241.6 PN6 standard


454
560 pool mouth
660
1400

P Fixed base mounting M to


M
4-25
520520
600600
242

270
850

324
670
325

420 284

27/ 28
Specialists in Pumps for
More Than 20 Years.

Performance Curve
Main Parameters
H(m)
Discharge Diameter 100mm
70

1
60

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
50 (mm) (kW) (r/min) (kg)
2 1 WQ2290-2126 48 37 2945 420
40
2 WQ2290-2125 48 30 2945 400
Pa(kW)

number
1 Rated current Motor Power Motor Stall torque /
40

Serial
Factor efficiency Rated torque
30 (A) c os (%)
20
2 1 68 0.90 92.0 2.2
10
2 56 0.90 91.2 2.1
3
0 30 60 90 120 150 180 Q (m /h)

Installation Dimensional Drawing


Z Automatic coupling installation
950x650

B B to
28
60 A

40
663
128 485

18
1583
26

280
810
480

340
300
25

137

A to
950
Flange dimensions
pool side 4-24
100
191 166

170
650
430
360

210
4-17.5

233 Flange press GB/T17241.6 PN6 standard


350 pool mouth
420
931

P Fixed base mounting M to

M
4-25
500x500
420x420
191 166
1280

200
760
255

300 178

WQ Series Submersible Sewage Pump


Main Parameters
Performance Curve
Discharge Diameter 100mm
H(m)
60

number
50 Flow Channel Motor Rated Rotating pump

Serial
1 Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
40
1 WQ2290-2132 48 37 2945 430
2
30 2 WQ2290-2131 48 30 2945 410

number
Pa(kW) Rated current Motor Power Motor Stall torque /

Serial
20 Factor efficiency
1 40 Rated torque
(A) c os (%)
10 30
1 68 0.90 92.0 2.2
20
2
10 2 56 0.90 91.2 2.1
3
0 40 80 120 160 200 240 280 Q (m /h)

Installation Dimensional Drawing


Z Automatic coupling installation
950x650

B B to
28
60 A

40
673
128 485

18
1583
26

280
810
480

340
300
25

134

A to 950
Flange dimensions
pool side 4-24
100
212 175

170
650
430
360

210
4-17.5

233 Flange press GB/T17241.6 PN6 standard


350 pool mouth
420
946

P Fixed base mounting M to

M
4-25
500x500
420x420
212 175
1283

200
776
246

300 193

29/30
Specialists in Pumps for
More Than 20 Years.

Performance Curve Main Parameters


Discharge Diameter 150mm
H(m)

number
50 Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
45 (mm) (kW) (r/min) (kg)
1
1 WQ2290-4135 89 30 1470 550
2
40
2 WQ2290-4135A 89 30 1470 545
3
35 3 WQ2290-4135B 89 30 1470 540

number
Rated current Motor Power Motor Stall torque /

Serial
30 Factor efficiency
Pa(kW) (A) Rated torque
c os (%)
1
30 0.86
1 58 92 2.2
20
2 10 2 58 0.86 92 2.2
3
3 58 0.86 92 2.2
0 40 80 120 160 200 240 Q (m 3/h)

Installation Dimensional Drawing


Z Automatic coupling installation
1300x1000

B 28
B to
60 A

40
854

18
128 595
1712
25

320
480

885

380
300
25

70
100

A to
1300 Flange dimensions
pool side 4-26
150
225
245

265
1000
440
360

8-17.5
273

Flange press GB/T17241.6 PN6 standard


253
350
pool mouth
430
1148

P Fixed base mounting M to

M
4-25
520X520
600X600
245
1412

240
273
885
300

440 259

WQ Series Submersible Sewage Pump


Performance Curve Main Parameters
H(m) Discharge Diameter 150mm
40

number
1 Flow Channel Motor Rated Rotating pump

Serial
30 Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
2
20 1 WQ2290-4134 76 30 1475 570
2 WQ2290-4134A 76 30 1475 565
10
Pa(kW)

number
Rated current Motor Power Motor Stall torque /
1

Serial
30 Factor efficiency Rated torque
(A) c os (%)
20
2 1 58 0.86
10 92 2.2
2 58 0.86 92 2.2
3
0 60 120 180 240 300 360 420 Q (m /h)

Installation Dimensional Drawing


Z Automatic coupling installation
1300x1000

B 28
B to
60 A

40
854

18
128 595
1712
25

320
480

885

380
300
25

70
100

A to
1300 Flange dimensions
pool side 4 26
150
225
245

265
1000
440
360

8- 17.5
273

Flange press GB/T17241.6 PN6 standard


253
350
pool mouth
430
1148

P Fixed base mounting M to

M
4- 25
520X520
600X600
245
1412

240
273
885
300

440 259

31/ 32
Specialists in Pumps for
More Than 20 Years.

Performance Curve Main Parameters


H(m) Discharge Diameter 150mm

60

number
1 Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
50 (mm) (kW) (r/min) (kg)

40 1 WQ2290-4171 76 55 1475 700


2
2 WQ2290-4170 76 45 1475 650
30
Pa(kW)

number
Rated current Motor Power Motor Stall torque /

Serial
60 Factor efficiency Rated torque
1 (A) c os (%)
50
40 1 103 0.87 93.2 2.2
30
2 2 85 0.87
20 93 2.2

0 50 100 150 200 250 300 350 Q (m 3/h)

Installation Dimensional Drawing


Z Automatic coupling installation
1300x1000

B B to 28

60 A

40
940

18
128 655
1726
25

320
480

908

380
300
25

92
100

A to
1300 Flange dimensions

pool side 4 26
150
225
245

265
1000
440
360

8- 17.5
273

Flange press GB/T17241.6 PN6 standard


253
350
pool mouth
430
1148

P Fixed base mounting M to

M
4- 25
520X520
600X600
265
1427

240
297
910
302

500 280

WQ Series Submersible Sewage Pump


Main Parameters
H m Performance Curve Discharge Diameter 200mm
50

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
40 mm
(mm) (kW)kW r (r/min)
min kg (kg)
1
2 1 WQ2290 4175 113 55 1470 745
30
2 WQ2290 4174 113 45 1470 680

20 3 WQ2290 4173 113 37 1470 570


3
4 4 WQ2290 4172 113 30 1470 515
10 5 5 30 510
WQ2290 4172A 113 1470
Pa kW
1 2

number
Rated current Motor Power Motor
60 Stall torque /

Serial
Factor efficiency Rated torque
50 (A) c os (%)
40 1 103 0 87 93 2 2 2
30
2 85 0 87 93 2 2
20
3 4 5 3 70 0 87 92 5 2 2
10
4 58 0 86 92 0 2 2
0 100 200 300 400 500 600 Q m3 h 5 58 0 86 92 0 2 2

Installation Dimensional Drawing


Z Automatic coupling installation
13001000
B to
B
28
72 A
926

40
274 642

18
1804
32 25

985
615

370
375

430
160
100

A to
Flange dimensions
1300
pool side 4-33
200
280
314 255

320
650
550

1000

8 -17.5

Flange press GB/T17241.6 PN6 standard


454
560
pool mouth
660
1430

P Fixed base mounting M to

M
4-25
520520
600600
255
1429

240
314
930
320

450 284

33/34
Specialists in Pumps for
More Than 20 Years.

Main Parameters
Discharge Diameter 250mm
Performance Curve
H m
40

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
1 (mm) (kW) (r/min) (kg)
30
2
1 WQ2290 4168 130 55 1470 750
20
2 WQ2290 4112 130 45 1470 685
3
10 3 WQ2290 4110 130 37 1470 640
4
0 4 WQ2290 4109 130 30 1470 620

number
Rated current Motor Power Motor Stall torque /
Pa kW

Serial
Factor efficiency Rated torque
1 2 (A) c os (%)
60
50 1 103 0 87 93 2 2 2
40
2 85 0 87 93 2 2
30
20 3 70 0 87 92 5 2 2
3 4
10
4 58 0 86 92 2 2
0 100 200 300 400 500 600 700 800 Q m3 h

Installation Dimensional Drawing


Z Automatic coupling installation
15001000
B to
B
28
82 A
1055

50
303 737
18
1880
42 27

1052
720

420
430

480
209
100

A to
Flange dimensions
1500
pool side 4-40
250
335
365 273

375
800
700

1000

1 2-17.5

Flange press GB/T17241.6 PN6 standard


488
650
pool mouth
750
1593

P Fixed base mounting M to


M
4-25
520520
600600
273
1450

270
365
948
327

510 319

WQ Series Submersible Sewage Pump


Main Parameters
Discharge Diameter 300mm
Performance Curve
H m

number
30 Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
25
1 WQ2290 4118 136 55 1470 1080
1
20 2 136 45 1470 980
2 WQ2290 4117
15 3 WQ2290 4116 136 37 1470 900

10 4 WQ2290 4115 136 30 1470 850


3

number
4 Rated current Motor Power Motor Stall torque /

Serial
5 Factor efficiency Rated torque
Pa kW (A) c os (%)
0 60 1 103 0 87 93 2 2 2
1 2
50
40 2 85 0 87 93 2 2
30 1 70 0 87 92 5 2 2
20
3 4 2 58 0 86 92 2 2

0 150 300 450 600 750 900 105012001350Q m 3 h

Installation Dimensional Drawing


Z Automatic coupling installation

15001000
B to
B
28
100 A
1162

60
375 845
18
1867
45 30

1048
765

480
425

540
193
150

A to
Flange dimensions
1500
pool side 4-40
300
395
352 278

440
880
780

1000

12-22

Flange press GB/T17241.6 PN6 standard


625
1000
pool mouth
1100
1837

P Fixed base mounting M to

M
4-30
700700
800800
278
1442

370
352
1035
412

580 317

35/ 36
Specialists in Pumps for
More Than 20 Years.

Main Parameters
Performance Curve Discharge Diameter 300mm
H m
12

number
10 Flow Channel Motor Rated Rotating pump
2

Serial
Pump Type Size Power Speed weight
8 1 (mm) (kW) (r/min) (kg)
6
4 1 WQ2290 6157 113 22 980 800
3
2 WQ2290 6156 113 18 5 980 780
3 WQ2290 6155 113 15 980 765
P a kW

number
2 24 Rated current Motor Power Motor Stall torque /
1

Serial
Factor efficiency Rated torque
20 (A) c os (%)
16
12 1 45 0 83 90 5 2 1
3
2 38 0 82 90 2 1
m3 h
350 550 750 950 1150 3 31 0 83 90 2 1

Installation Dimensional Drawing


Z Automatic coupling installation
16001200

B B to 28

100 A

60
1228

18
375 840

480
1730
30

584
965
765

425
45

150
150

A to
1600 Flange dimensions
pool side 4-40

300
331

395
1200
880
780

440
445

1 2-2 2

625 Flange press GB/T17241.6 PN6 standard


1000
pool mouth
1100
1903

P Fixed base mounting M to


M
4-30
900900
800800
331
1304

470
1 005

445
465

575 388
120-200

470
1100

WQ Series Submersible Sewage Pump


H(m) Performance Curve
80 Main Parameters
Discharge Diameter 150mm
1
70

number
Flow Channel Motor Rated Rotating pump

Serial
60 Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
50 1 WQ2368-4166 82 90 1485 1100
2
2 WQ2368-4165 82 75 1485 1010
40

number
Rated current Motor Power Motor Stall torque /
Pa(kW)

Serial
30 Factor efficiency Rated torque
1 (A) c os (%)
100
80 1 167 0.87 94.2 2.2
60
2 140 0.87 93.8 2.2
40
2
20
3
0 60 120 180 240 300 360 420 480 Q (m /h)

Installation Dimensional Drawing


Z Automatic coupling installation
15001000

B B to
A
28
128 991
675

40


DN150PN0.6MPa

18

1860
25 25

860
480

320
300

380
50
100

A to
1500
4-26 Flange dimensions
pool side
150
225
297
360

1000
440

265
335

8-17.5

253
350 Flange press GB/T17241.6 PN6 standard
pool mouth
430
1285

P Fixed base mounting


M to
M

4-25
1560

600600
520520
335 297
895

240
335

520 316
165

220
820

37/38
Specialists in Pumps for
More Than 20 Years.

H(m) Performance Curve


Main Parameters
60
Discharge Diameter 200mm
50
1

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
40 (r/min) (kg)
(mm) (kW)
2 1 1485
30 WQ2368-4146 96 90 1170
2 WQ2368-4145 96 75 1485 1080
20

number
Rated current Motor Power Motor Stall torque /

Serial
Pa(kW) Factor efficiency
10 (A) Rated torque
1 c os (%)
100
0 80 1 167 0.87 94.2 2.2
60 2 140 0.87 93.8 2.2
2
40
3
0 125 250 375 500 625 750 875 Q (m /h)

Installation Dimensional Drawing


Z Automatic coupling installation

15001000 B to
B 28

72 A

40
1088

18
274 742

370
1948
25

430
959
615

375
35

138
100

A to
1500
Flange dimensions
pool side 4-33

200
312

280
1000
650
550

320
372

8-17.5

454 Flange press GB/T17241.6 PN6 standard


560
pool mouth
660
1590

P Fixed base mounting M to

M
4-25
600600
520520
312
1573

240
915

372
332

550 346
120-150

240
820

WQ Series Submersible Sewage Pump


H m Performance Curve Main Parameters
50 Discharge Diameter 250mm

40

number
1 Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
30
2 1 WQ2368-4150 138 90 1485 1230
20 2 WQ2368-4149 138 75 1485 1110
Pa kW

number
Rated current Motor Power Motor
1 Stall torque /

Serial
100 Factor efficiency
10 (A) (%)
Rated torque
c os
75
1 167 0.87 94.2 2.2
50
2 2 140 0.87 93.8 2.2

300 450 600 750 900 Q m h


3
0 150

Installation Dimensional Drawing


Z Automatic coupling installation

15001000 B to
B 28

82 A

50
1050

18
303 727

420
2001
27

480
1018
720

430
42

155
100

A to
Flange dimensions
1500
pool side 4-40

250
291

335
1000
800
700

375
354

12-17.5

Flange press GB/T17241.6 PN6 standard


488
650
pool mouth
750
1588

P Fixed base mounting M to

M
4-30
900900
800800
291
1571

420
1053

354
465

500 323
100

420
1100

39/ 40
Specialists in Pumps for
More Than 20 Years.

Main Parameters
Performance Curve Discharge Diameter 300mm
H(m)
36

number
Flow Channel Motor Rated Rotating pump

Serial
1 Pump Type Size Power Speed weight
28 (mm) (kW) (r/min) (kg)

20 1 WQ2368-4120 157 90 1485 1650


2
2 WQ2368-4120A 157 75 1485 1500
12

number
Rated current Motor Power Motor Stall torque /

Serial
Factor efficiency Rated torque
Pa(kW) (A) c os (%)
1
80 1 167 0.87 94.2 2.2
60
2 140 0.87 93.8 2.2
40
2
3
0 200 400 600 800 1000 1200 1400 Q (m /h)

Installation Dimensional Drawing


Z Automatic coupling installation

16001200

B B to
100 A
1212 28
375 815

60
18
2032
1044
30
765

425
45

480
540
150
152

A to
1600 Flange dimensions
pool side 4-40

300
330

395
1200
880
780

440
446

12-23

625 Flange press GB/T17241.6 PN6 standard


1000
pool mouth
1100
1887

P Fixed base mounting M to


M
4-30
1067

900900
800800
446 330

470
1101
482

550 397
100-150

470
1100

WQ Series Submersible Sewage Pump


H m Performance Curve
40
Main Parameters
30 Discharge Diameter 300mm

20 Flow Channel Motor Rated Rotating pump


Pump Type Size Power Speed weight
10 (mm) (kW) (r/min) (kg)
Pa kW WQ2368-4121 157 90 1485 1657
0 100 Rated current Motor Power Motor
Factor efficiency Stall torque /
80 (A) c os (%) Rated torque
60 167 0.87 94.2 2.2

200 400 600 800 1000 1200 1400 1600 1800 Q m h


3
0

Installation Dimensional Drawing


Z Automatic coupling installation

16001200

A B to
100 28
1212

60
375 815

18
2032
30

1044
765

425
45

480
540
150
152

A to
1600 Flange dimensions
pool side 4-40

300
330

395
1200
880
780

440
446

12-23

625 Flange press GB/T17241.6 PN6 standard


1000
pool mouth
1100
1887

P Fixed base mounting M to


M

4-30
1607

900900
800800
44 6 330
1101

470
482

550 397
100-150

470
1100

41/42
Specialists in Pumps for
More Than 20 Years.

Main Parameters
Performance Curve Discharge Diameter 350mm
H(m)

number
14 Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
1 (mm) (kW) (r/min) (kg)
10
1 WQ2368-6159 114 37 980 1180
6 2
Pa(kW) 2 WQ2368-6158 114 30 980 1150

number
40 Rated current Motor Power Motor Stall torque /

Serial
1 Factor efficiency Rated torque
35 (A) c os (%)
2 30
25 1 71 0.86 91.7 2.3
2 58 0.85 91.6 2.1
3
550 800 1050 1300 1550 Q (m /h)

Installation Dimensional Drawing


Z Automatic coupling installation
1900 1500

B
A
100 28
1506
B to
390 1015

60
18
2036
1135
30 50
1000

580
640
600
310
100

A to
1900
Flange dimensions
pool side 6-40

350
422

1500

445
880
780

490
554

12-23

425 Flange press GB/T17241.6 PN6 standard


630 pool mouth
1100
1200
2171

P Fixed base mounting M to


M
4-40
1436

11001100
10001000
422
1080

470
554
550

100-200

730 491
670
1450

WQ Series Submersible Sewage Pump


Main Parameters
Performance Curve Discharge Diameter 350mm
H(m)
16

number
Flow Channel Motor Rated Rotating pump

Serial
12 Pump Type Size Power Speed weight
1 (mm) (kW) (r/min) (kg)
8 1 WQ2368-6161 114 55 980 1550
2
4 Pa(kW) 2 WQ2368-6160 114 45 980 1500

number
1 Rated current Motor Power Motor
55 Stall torque /

Serial
50 Factor efficiency Rated torque
(A) c os (%)
2 45
40 1 105 0.86 92.8 2.3
2 86 0.86 92.5 2.3
3
700 1000 1300 1600 1900 Q (m /h)

Installation Dimensional Drawing


Z Automatic coupling installation
19001500

B B to
A 28
100
1496

60
390 1015

18
2176
1205
30 50
1000

580
640
600
330
100

A to
1900
Flange dimensions
pool side 6-40

350
422

1500

445
880
780

490
554

12-23

425 Flange press GB/T17241.6 PN6 standard


630 pool mouth
1100
1200
2171

P Fixed base mounting M to


M
4-40
1576

11001100
10001000
422
1155

470
554
550

100-200

730 491
670
1450

43/ 44
Specialists in Pumps for
More Than 20 Years.

Performance Curve Main Parameters


Discharge Diameter 350mm

H(m)

number
8 Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
6 1
1 WQ2368-8154 91 22 730 1400
4 2
2 WQ2368-8153 91 18.5 730 1350
Pa(kW) 3 WQ2368-8152 91 15 730 1300
2 3 1
20

number
2 Rated current Motor Power Motor Stall torque /

Serial
16 Factor efficiency
(A) Rated torque
12 c os (%)
3 8 1 47 0.8 90.7 2.0
2 40 0.77 90.1 2.0
600 800 1000 1200 1400 3 3 35 0.76 88.5 2.0
Q (m /h)

Installation Dimensional Drawing


Z Automatic coupling installation
19001500

B
A B to
100 28
1335

60
390 915

18
1976
1130
30 50
1000

580
640
600
225
100

A to
1900 Flange dimensions
pool side 6-40

350
351

1500

445
880
780

490
490

12-23

425 Flange press GB/T17241.6 PN6 standard


630 pool mouth
1100
1200
2015

P Fixed base mounting M to


M
4-30
1376

900900
800800
351
1065

520
490
533

630 420
150

500
1100

WQ Series Submersible Sewage Pump


Performance Curve Main Parameters
Discharge Diameter 400mm
H(m)

number
10 Flow Channel Motor Rated Rotating pump

Serial
1 Pump Type Size Power Speed weight
8 (mm) (kW) (r/min) (kg)
6 1 WQ2368-8156 104 37 735 1560
2
2 WQ2368-8155 104 30 735 1500
4

number
Pa(kW) Rated current Motor Power Motor Stall torque /

Serial
1 Factor efficiency Rated torque
2 40 (A) c os (%)
30
20 1 78 0.79 91.5 2.0
2 63 0.8 90.7 1.9

3
700 1000 1300 1600 1900 Q (m /h)

Installation Dimensional Drawing


22001800
Z Automatic coupling installation
B
A B to 28
100
1724

60
390 1135

18
2066
1096
30 50
1000

580
640
600
255
150

A to
2200
Flange dimensions
pool side 6-40

400
662 507

1800

515
880
780

565
16-26

425 Flange press GB/T17241.6 PN6 standard


630 pool mouth
1100
1200
2404

P Fixed base mounting M to


M
4-40
1466

12001200
11001100
507
1136

670
662
640

850 589
150

670
1500

45/46
Specialists in Pumps for
More Than 20 Years.

Performance Curve Main Parameters


Discharge Diameter 400mm
H(m)

number
Flow Channel Motor Rated Rotating pump

Serial
10 Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
8
1 1 WQ2368-8158 104 55 735 1670
2
6 2 WQ2368-8157 104 45 735 1640
Pa(kW)

number
Rated current Motor Power Motor Stall torque /

Serial
4 1 55 Factor efficiency Rated torque
50 (A) c os (%)
45 0.81 1.8
2 1 115 92.8
40
35 2 95 0.79 92 2.0

3
1000 1400 1800 2200 2600 Q (m /h)

Installation Dimensional Drawing


22001800 Z Automatic coupling installation
B
A B to 28
100
1724

60
390 1135

18
2066
1236
30 50
1000

580
640
600
255
150

A to
2200
Flange dimensions
pool side 6-40

400
507

1800

515
880
780

565
662

16-26

425 Flange press GB/T17241.6 PN6 standard


630 pool mouth
1100
1200
2404

P Fixed base mounting M to


M
4-40
1606

12001200
11001100
507
1276

670
662
640

850 589
150

670
1500

WQ Series Submersible Sewage Pump


Performance Curve Main Parameters
H( m)
Discharge Diameter 200mm
90
1

number
Flow Channel Motor Rated Rotating pump

Serial
75 Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
60 1 WQ2445-4148 96 160 1485 1700

45 2 WQ2445-4147 96 132 1485 1600


2

number
Rated current Motor Power Motor Stall torque /

Serial
30 Factor efficiency Rated torque
Pa(kW) (A) c os (%)
1 242 0.88 94 2.1
160
1 2 202 0.88 94 2.2
140
120
2

0 100 200 300 400 500 600 700 800 Q (m /h)


3

Installation Dimensional Drawing


Z Automatic coupling installation
16001200

B B to 28
72 A

40
1092

18
274 742

370
2261
25

430
1142
615

375
35

100
90

A to
1600 Flange dimensions
pool side 4-33
200
370 329

295
1200
650
550

340
8-22

454 Flange press GB/T17241.6 PN6 standard


560
pool mouth
660
1596

P Fixed base mounting M to

M
4-30
800800
700700
329
1886

420
370
1232
425

550 350

47/ 48
Specialists in Pumps for
More Than 20 Years.

Main Parameters
Discharge Diameter 250mm
Performance Curve

number
Flow Channel Motor Rated Rotating pump
H(m)

Serial
Size Power Speed weight
Pump Type
60 (mm) (kW) (r/min) (kg)
1 1 WQ2445-4153 110 160 1485 2250
50 2 3 2 WQ2445-4152 110 132 1485 2010
4 3 WQ2445-4152A 110 110 1485 1850
40
4 WQ2445-4151 110 110 1485 1840
5 Pa(kW) 5 WQ2445-4151A 110 110 1485 1830
30

number
175 Rated current Motor Power Motor Stall torque /

Serial
1 Factor efficiency
150 (A) Rated torque
2 c os (%)
125
3 1 294 0.88 94 2.1
100
75 2 242 0.88 94 2.2
50 3 201 0.88 94 2.2
4 5
4 201 0.88 94 2.2
3 5 201 0.88 94 2.2
0 150 300 450 600 750 900 1050 1200 Q (m /h)

Installation Dimensional Drawing


Z Automatic coupling installation
16001200

B B to 28
82 A

50
1242

18
303 877

420
2328
27

480
1112
720

430
42

100
165

A to
1600 Flange dimensions
pool side 4-40
250
335
395 332

1200
800
700

375
12-17.5

488 Flange press GB/T17241.6 PN6 standard


650
pool mouth
750
1780

P Fixed base mounting M to

M
4-30
700700
800800
332
1898

370
395
1192
413

650 365

WQ Series Submersible Sewage Pump


H m
Performance Curve Main Parameters
50
Discharge Diameter 300mm

40
1

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
30 (mm) (kW) (r/min) (kg)
20 2 1 WQ2445 4140 128 160 1485 2520
3 2320
2 WQ2445 4140A 128 132 1485
10 3 WQ2445 4139 128 110 1485 2120
Pa kW
1

number
0 2 160 Rated current Motor Power Motor Stall torque /

Serial
Factor efficiency Rated torque
140 (A) c os (%)
120
1 294 0 88 94 2 1
100
3 80 2 242 0 88 94 2 1
60 3 202 0 88 94 2 2

200 400 600 800 1000 1200 14001600 1800 m h


3
0

Installation Dimensional Drawing


Z Automatic coupling installation
16001200

B B to 28
100 A

60
1323

18
375 915

480
2354
45 30

1229

540
765

425
200
136

A to
1600 Flange dimensions
pool side 4-40
300
395
450 360

1200
880
780

440
12-22

625 Flange press GB/T17241.6 PN6 standard


1000
pool mouth
1100
1998

P Fixed base mounting M to


M
4-30
1923

800800
900900
360
1283

470
450
464

650 408
150

470
1100

49/50
Specialists in Pumps for
More Than 20 Years.

Performance Curve Main Parameters


H(m)
60 Discharge Diameter 300mm

number
50 Flow Channel Motor Rated Rotating pump

Serial
1 Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
40
1 WQ2445-4141 128 160 1485 2520
30 2 2 WQ2445-4141A 128 132 1485 2300

number
Rated current Motor Power Motor Stall torque /

Serial
Pa(kW) Factor efficiency Rated torque
(A) c os (%)
200
1 1 294 0.88 94 2.1
150
100 2 242 0.88 94 2.2
2

3
0 200 400 600 800 1000 1200 1400 Q (m /h)

Installation Dimensional Drawing


Z Automatic coupling installation
16001200
B to
B 28
100 A

60
1323

18
375 915

480
2354
45 30

1229

540
765

425
200
136

A to
1600 Flange dimensions
pool side 4-40
300
395
450 360

1200
880
780

440
12-22

625 Flange press GB/T17241.6 PN6 standard


1000
pool mouth
1100
1998

P Fixed base mounting M to


M
4-30
1923

800800
900900
360
1283

470
450
464

650 408
150

470
1100

WQ Series Submersible Sewage Pump


Main Parameters
H(m) Performance Curve Discharge Diameter 350mm

28

number
Flow Channel Motor Rated Rotating pump

Serial
24 Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
1
20
1 WQ2445-6124 130 132 990 2500
2
16 3 2 130
WQ2445-6123 110 990 2320
12 4 3 WQ2445-6122 130 90 990 2160
8 4 WQ2445-6121 130 75 990 2000
Pa(kW)

number
Rated current Motor Power Motor Stall torque /

Serial
140 Factor efficiency
1 2 120 Rated torque
(A) c os (%)
100
80 1 245 0.87 94.2 2.1
3 60
4 40 2 207 0.86 94 2.1
20 0.86 93.8 2.0
3 170
0 600 1200 1800 2400 Q (m 3/h) 0.86 93.5
4 142 2.0

Installation Dimensional Drawing


22001500
Z Automatic coupling installation

B
A B to 28
100
1658

60
390 1135

18
2556
1437
30 50

580
1000

640
600
296
100

A to
2200
Flange dimensions
pool side 6-40

350
585 453

1500

445
880
780

490
12-23

425 Flange press GB/T17241.6 PN6 standard


630 pool mouth
1100
1200
2338

P Fixed base mounting M to


M
4-30
1956

800800
900900
453
1331

520
585
492

850 523
250

500
1200
51/ 52
Specialists in Pumps for
More Than 20 Years.

Main Parameters
H(m) Performance Curve
Discharge Diameter 400mm
20

number
Flow Channel Motor Rated Rotating pump

Serial
16 Pump Type Size Power Speed weight
1 (mm) (kW) (r/min) (kg)
2
12 1 138
3 WQ2445-6165 132 990 2540
4
8 2 WQ2445-6164 138 110 990 2380
Pa(kW) 3 WQ2445-6163 138 90 990 2230
4
1 130 4 WQ2445-6162 138 75 990 2100
120

number
110 Rated current Motor Power Motor Stall torque /

Serial
2 Factor efficiency
100 (A) Rated torque
c os (%)
90
3 80 1 245 0.87 94.2 2.1
4 70 2 207 0.86 94 2.1
60
50 3 170 0.86 93.8 2.0
3
900 1500 2100 2700 3300 Q (m /h)
4 142 0.86 93.5 2.0

Installation Dimensional Drawing


22001800 Z Automatic coupling installation
B B to 28
A
100
1709

60
390 1135

18
2567
1442
30 50

580
1000

640
600
255
150

A to
2200 Flange dimensions
pool side 6-40

400
642 498

1800

515
880
780

565
16-26

425 Flange press GB/T17241.6 PN6 standard


630 pool mouth
1100
1200
2389

P Fixed base mounting M to


M
4-40
1967

11001100
12001200
498
1497

670
642
655

850 574
100

670
1500

WQ Series Submersible Sewage Pump


Main Parameters
Discharge Diameter 300mm
H(m) Performance Curve

number
70 Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
1 (mm) (kW) (r/min) (kg)
60
2 1 1485 2500
WQ2520-4164 100 280
50 2 WQ2520-4163 100 250 1485 2300

40 3 WQ2520-4162 100 220 1485 2150


3
4 4 WQ2520-4161 100 200 1485 2050
30 Pa(kW)
5 5 WQ2520-4160 100 185 1485 2000
2 1

number
20 300 Rated current Motor Power Motor Stall torque /

Serial
250 Factor efficiency Rated torque
200 (A) c os (%)
150 1 495 0.90 95.5 2.2
5 4 3 100 2 450 0.89 95 2.2
3 396 0.89 95 2.2
3
0 200 400 600 800 1000 1200140016001800 Q (m /h) 4 363 0.89 94 2.2
5 340 0.88 94 2.1

Installation Dimensional Drawing


Z Automatic coupling installation

16001200

B
150
B to 28
A
1410
60

315 975
18
2530
30

1250
765

425
45

480
540
165
250

A to
1600
Flange dimensions
pool side 4-40

300
480 385

1200
880
780

395
440
12-22

565 Flange press GB/T17241.6 PN6 standard


1000
pool mouth
1100
2024

53/54
Specialists in Pumps for
More Than 20 Years.

Performance Curve
H(m) Main Parameters
50 Discharge Diameter 400mm

40

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
35 1 (mm) (kW) (r/min) (kg)
2 1 WQ2520-6103 163 200 990 2600
30
2 WQ2520-6102 163 185 990 2500
25 3 WQ2520-6101 163 160 990 2360
3

number
20 Rated current Motor Power Motor Stall torque /

Serial
Factor efficiency Rated torque
Pa(kW) (A) c os (%)
15
1 200 1 363 0.88 95 2.0
2
160 2 337 0.88 94.9 2.0
120
3 3 291 0.88 94.8 2.0
80
3
0 400 800 1200 1600 2000 2400 2800 Q (m /h)

Installation Dimensional Drawing


22001500 Z Automatic coupling installation
B
A B to 28
100
1718

60
390 1145

18
2730
1457
30 50
1000

580
640
600
262
150

A to 2200
Flange dimensions
pool side 6-40

400
628 506

1500

515
880
780

565
16-26

425 Flange press GB/T17241.6 PN6 standard


630 pool mouth
1100
1200
2398

P Fixed base mounting M to


M
4-40
2130

11001100
12001200
506
1490

670
628
608

860 573
150

670
1500

WQ Series Submersible Sewage Pump


H(m) Performance Curve Main Parameters
35 Discharge Diameter 400mm

30

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
25 1 (mm) (kW) (r/min) (kg)
2 1 WQ2520-6126 163 200 990 2950
20
2 WQ2520-6125 163 185 990 2800
3
15 3 WQ2520-6104 163 160 990 2580

number
10 Rated current Motor Power Motor Stall torque /

Serial
Pa(kW) Factor efficiency Rated torque
1 (A) c os (%)
200
150 1 363 0.88 95 2.0
2
3 100 2 337 0.88 94.9 2.0
50
3 291 0.88 94.8 2.0
3
0 500 1000 1500 2000 2500 3000 3500 Q (m /h)

Installation Dimensional Drawing


22001500 Z Automatic coupling installation
B B to
28
A
100
1718

60
390 1145

18
2730
1457
30 50

580
1000

640
600
262
150

A to
2200
Flange dimensions
pool side 6-40

400
628 506

1500

515
880
780

565
16-26

425 Flange press GB/T17241.6 PN6 standard


630 pool mouth
1100
1200
2398

P Fixed base mounting M to


M
4-40
2130

11001100
12001200
506
1490

670
628
608

860 573
150

670
1500

55/ 56
Specialists in Pumps for
More Than 20 Years.

Performance Curve Main Parameters


Discharge Diameter 500mm
H(m)
1

number
20 Flow Channel Motor Rated Rotating pump

Serial
2 Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
15
1 WQ2520-6110 163 200 990 3980
3 163
10 2 WQ2520-6109 185 990 3810

Pa(kW) 3 WQ2520-6108 163 160 990 3605


5
1

number
2 Rated current Motor Power Motor
200 Stall torque /

Serial
Factor efficiency Rated torque
175 (A) c os (%)
150 1 363 0.88 95 2.0
125
3 2 337 0.88 94.9 2.0
100
3 291 0.88 94.8 2.0
3
600 1200 1800 2400 3000 3600 4200 4800 Q (m /h)

Installation Dimensional Drawing


22001500 Z Automatic coupling installation
B B to 28
A
100
1729

60
595 1155

18
2830
1557
50 34

580
1300

640
700
362
152

A to
2200
Flange dimensions
pool side 6-48

500
628 506

1500

620
950
830

670
20-26

570 Flange press GB/T17241.6 PN6 standard


740 pool mouth
1140
1260
2529

P Fixed base mounting M to


M
4-40
2130

11001100
12001200
506
1465

670
628
608

860 574
250

670
1450

WQ Series Submersible Sewage Pump


Performance Curve Main Parameters
Discharge Diameter 500mm
H(m)
18

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
16 mm
(mm) (kW)kW r (r/min)
min kg (kg)

1 1 WQ2520-8163 174 160 745 3630


12
2 2 WQ2520-8162 174 132 745 3450
3
8 3 WQ2520-8161 174 110 735 3220
4
5 Pa(kW) 4 WQ2520-8160 174 90 735 3010
4
160 5 WQ2520-8159 174 75 735 2890
1
140

number
2 Rated current Motor Power Motor Stall torque /

Serial
120 Factor efficiency
3 (A) Rated torque
100 c os (%)
4 1.9
80 1 315 0.83 93.5
60 1.9
5 2 265 0.82 93.5
40
3 220 0.82 94 1.9
3
800 1600 2400 3200 4000 Q (m /h) 4 180 0.82 93.8 1.8
5 150 0.81 93 1.8

Installation Dimensional Drawing


24001900 Z Automatic coupling installation
B
A
100 B to
1998 28
595 1315

60
18
2938
1665
50 34
1300

700

580
640
140
350

A to 2400
Flange dimensions
pool side 6-48

500
757 597

1900

620
950
830

670
20-28

570 Flange press GB/T17241.6 PN6 standard


740 pool mouth
1140
1260
2798

F Fixed base mounting K to


K
1350
1200
2238

1410

683

550
700
460

1020

4-40
300

800
500

900
597 757
57/58
Specialists in Pumps for
More Than 20 Years.

Main Parameters
Discharge Diameter 500mm

Performance Curve

number
H(m) Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
12
2
1 WQ2520-1057 200 132 590 4500
1
8
2 WQ2520-1056 200 110 590 4250
4 3
4 3 WQ2520-1055 200 90 590 4000
Pa(kW)
4 WQ2520-1054 200 75 590 3800
0 160

number
140 Rated current Motor Power Motor Stall torque /

Serial
1 Factor efficiency Rated torque
120 (A) c os (%)
100
3 2 1 275 0.78 93.5 1.3
80
60 2 230 0.78 93.2 1.3
4
40 3 191 0.77 93 1.5

1600 2400 3200 4000 4400 Q (m /h)


3
4 163 0.76 92.5 1.5

Installation Dimensional Drawing


26002000 Z Automatic coupling installation
B
A
100 B to
2166 28
635 1400

60
18
3015
1800
55 36
1400

760

650
720
122
500

A to
2600
Flange dimensions
pool side 6-48

600
853 648

2000
1210
1090

725
780
20-31

590 Flange press GB/T17241.6 PN6 standard


770 pool mouth
1180
1300
2996

F Fixed base mounting K to


K
1600
1450
2255

1420

766

650
800
438

1100

4-48
400

1100
600

1250
648 853

WQ Series Submersible Sewage Pump


H(m) Performance Curve Main Parameters
60 Discharge Diameter 350mm

50

number
1 Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
40 2 (r/min)
(mm) (kW) (kg)
1 WQ2590-6114 169 250 990 4850
30
2 WQ2590-6113 169 220 990 4630
20

number
Pa(kW) Rated current Motor Power Motor Stall torque /

Serial
Factor efficiency Rated torque
2 1 (A) c os (%)
250
200 1 453 0.88 95.1 1.45
150
2 398 0.88 95.1 1.52
100
3
0 400 800 1200 16002000 2400 2800 Q (m /h)

Installation Dimensional Drawing


Z Automatic coupling installation
22001500

B
28
A
100
1604

60
390 1080

18
2982
1590
50 30

580
1000

640
600
265
100

2200
6-40

350
573 472

1500

445
880
780

490
12-23

425
630 pool mouth
1100
1200
2284

M
4-40
2382

11001100
12001200
472
1580

670
573
600

795 524
100

670
1500

59/ 60
Specialists in Pumps for
More Than 20 Years.

Performance Curve Main Parameters


H(m) Discharge Diameter 400mm
40

number
35 Flow Channel Motor Rated Rotating pump

Serial
1 Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
30
2 1 WQ2590-6107 190 280 990 5050
25 2 WQ2590-6106 190 250 990 4860
3 3 WQ2590-6105 190 220 990 4670
20

number
Rated current Motor Power Motor Stall torque /

Serial
Pa(kW) Factor efficiency
15 (A) Rated torque
1 c os (%)
2 300
250 1 507 0.88 95.2 1.5
200 2 453 0.88 95.1 1.45
150
3 1.52
100 3 398 0.88 95.1

0 500 1000 1500 2000 2500 3000 3500 4000


Q (m 3/h)

Installation Dimensional Drawing


Z Automatic coupling installation
22001800

B B to
28
A
100
1702

60
390 1135

18
2982
1590
50 30

580
1000

640
600
255
170

A to
2200
Flange dimensions
pool side 6-40

400
649 482

1800

515
880
780

565
16-26

425 Flange press GB/T17241.6 PN6 standard


630 pool mouth
1100
1200
2382

P Fixed base mounting M to


M
4-40
2382

11001100
12001200
482
1610

670
649
645

120-200

850 567
670
1500

WQ Series Submersible Sewage Pump


Performance Curve Main Parameters
Discharge Diameter 500mm
H(m)

35

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
30 (mm) (kW) (r/min) (kg)
1
2 1 WQ2590-6119 190 280 990 5480
25
2 WQ2590-6118 190 250 990 5170
20 3 WQ2590-6117 190 220 990 4860
3

number
Rated current Motor Power Motor Stall torque /

Serial
15 Factor efficiency
(A) Rated torque
c os (%)
1 Pa(kW)
10 2 507 0.88 1.5
310 1 95.2
3
250 2 453 0.88 95.1 1.45
190
3 398 0.88 95.1 1.52

3
0 600 1200 1800 2400 3000 3600 4200 Q (m /h)

Installation Dimensional Drawing


22001800 Z Automatic coupling installation
B to
B 28
A
100

60
1754
595 1175

18
3082

580
1662
50 34

640
1300

700
355
145

A to
2200
Flange dimensions
pool side 6-48

500
663 494

1800

620
950
830

670
20-28

570 Flange press GB/T17241.6 PN6 standard


740 pool mouth
1140
1260
2554

P
P Fixed base mounting M to
M
4-40
2382

12001200
11001100
494
1605

670
663
645

120-200

880 579
670
1500

61/62
Specialists in Pumps for
More Than 20 Years.

Performance Curve Main Parameters


Discharge Diameter 600mm
H( m)
22

number
Flow Channel Motor Rated Rotating pump
1

Serial
Pump Type Size Power Speed weight
2 (mm) (kW) (r/min) (kg)
18
3
1 WQ2590-8169 190 315 745 6100
14
4 2 WQ2590-8168 190 280 745 5800
5
10 3 WQ2590-8167 190 250 745 5500
6 4 WQ2590-8166 190 220 745 5200
6 Pa(kW)
1 5 WQ2590-8165 190 200 745 5000
300
2 280 6 WQ2590-8164 190 185 745 4850
3
260

number
Rated current Motor Power Motor Stall torque /
240

Serial
4 Factor efficiency Rated torque
5 220 (A) c os (%)
200
1 632 0.81 93.5 1.0
180
160 2 562 0.81 93.5 1.0
6 140 3 504 0.81 93 1.0
3000 3800 4600 5400 6200
4 1.0
3
Q (m /h) 446 0.81 92.5
5 386 0.83 94.8 1.9
6 360 0.83 94 1.9

Installation Dimensional Drawing


Z Automatic coupling installation

25002000
B to
B Flange dimensions
28
100
A
2130 600
60

635 1400 725


18

780
20-31
3176
36

1800

Flange press GB/T17241.6 PN6 standard


1400

650
760
55

720
144
500

A to K to
F Fixed base mounting

2500 K
pool side 1750
6-48
1600
2416
606

730
1210

2000
1090

1588

800
950
859

567

1100

4-48
300

590 980
600

770 pool mouth


1180 1150 606 859
1300
2960

WQ Series Submersible Sewage Pump


Performance Curve Main Parameters
Discharge Diameter 700mm
H(m)

number
Flow Channel Motor Rated Rotating pump

Serial
14 Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
10 1
1 WQ2590-1059 215 185 590 6500

6 2 2 WQ2590-1058 215 160 590 6200


Pa(kW)

number
1 Rated current Motor Power Motor Stall torque /

Serial
180 Factor efficiency Rated torque
160 (A) c os (%)
140 1 386 0.8 94 1.54
2
120
2 333 0.78 93.5 1.3
3
3000 4000 5000 6000 7000 Q (m /h)

Installation Dimensional Drawing

F Fixed base mounting


K

Flange dimensions
2800

700
2400

840
650

865
24-31
400

1200
800

Flange press GB/T17241.6 PN6 standard


1350

K to
2000
1800
820

1100
900
1400

4-46

680 960

63/ 64
Specialists in Pumps for
More Than 20 Years.

Main Parameters
Discharge Diameter 700mm

Performance Curve

number
Flow Channel Motor Rated Rotating pump

Serial
H(m) Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
14
1 WQ2590-1252 220 220 495 7400
12
1 2 WQ2590-1251 220 200 495 7100
10 3 WQ2590-1250 220 185 490 6800
2
3

number
8 Rated current Motor Power Motor
Pa(kW) Stall torque /

Serial
Factor efficiency Rated torque
(A) c os (%)
1 220
200
1 479 0.755 92.5 0.8
180
2
160 2 438 0.755 92 0.8
3
3000 4200 5400 6600 7800 Q (m /h)
3
3 392 0.78 92 1.0

Installation Dimensional Drawing

F Fixed base mounting


K

Flange dimensions
2800

700
2400

840
650

895
24-31
300

1200
800

Flange press GB/T17241.6 PN6 standard


1350

K to

2000
1800
820

1100
900
1400

4-46

680 960

WQ Series Submersible Sewage Pump


Main Parameters
Discharge Diameter 800mm

Performance Curve

number
Flow Channel Motor Rated Rotating pump
H(m)

Serial
Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
16
1 1 WQ2670-1255 250 315 495 8800
12
3 WQ2670-1254 250 280 495 8400
2 2
8
Pa(kW) 3 WQ2670-1253 250 250 495 8000
320

number
1 Rated current Motor Power Motor Stall torque /

Serial
280 Factor efficiency
(A) Rated torque
240 c os (%)
2 200
3
1 671 0.76 93.8 0.8

3500 5000 6500 8000


3
9500 Q (m /h) 2 597 0.76 93.8 0.8

3 537 0.76 93 0.8

Installation Dimensional Drawing

F Fixed base mounting


K

Flange dimensions
3000

800
2600

950
1015
700

24-34
300

1300 Flange press GB/T17241.6 PN6 standard


900

1450

K to
2100
1900
900

1200
1000
1500

4-46

750 1050

65/66
Specialists in Pumps for
More Than 20 Years.

H( m) Performance Curve

40

30 Main Parameters
Discharge Diameter 600mm
20

10 P a ( kW) Flow Channel Motor Rated Rotating pump


Pump Type Size Power Speed weight
500 (mm) (kW) (r/min) (kg)
450
400 WQ2740-6170 125 450 980 6300
350

2200 3000 3800 4600 Q( m 3 / h)

Installation Dimensional Drawing


Z Automatic coupling installation

22001900

B B to
A 28
1976
635 1290

60
18
3466
1875
55 36
1400

760

650
720
217
400

A to 2200

pool side 6-48 Flange dimensions

600
602
1210
1090

1900

725
780
752

20-30

590 Flange press GB/T17241.6 PN6 standard


770 pool mouth
1180
1300
2806

WQ Series Submersible Sewage Pump


H(m) Performance Curve

38
Main Parameters
34
Discharge Diameter 600mm
30
Flow Channel Motor Rated Rotating pump
Pump Type Size Power Speed weight
P a ( kW) (mm) (kW) (r/min) (kg)
600 WQ2850-8175 125 580 745 9800
550
500
450

3
3000 3800 4600 5400 Q( m / h)

Installation Dimensional Drawing


Z Automatic coupling installation

25001800

B B to
28
A

60
2145
635 1400

18
3900

650
55 36

2000
1400

720
760
190
350

A to 2400
pool side Flange dimensions
6-48
600
823 656

725
1900
1090
1210

780
20-31

Flange press GB/T17241.6 PN6 standard


590
770 pool mouth
1180
1300
2975

67/ 68
Specialists in Pumps for
More Than 20 Years.

H(m) Performance Curve Main Parameters


30 Discharge Diameter 900mm

25 1

number
Flow Channel Motor Rated Rotating pump

Serial
Pump Type Size Power Speed weight
2 (mm) (kW) (r/min) (kg)
20
1 WQ2850-8172 258 560 745 9500
15
2 WQ2850-8171 258 500 745 9100
3
3 WQ2850-8170 258 450 745 8800
10

P a ( kW)
1 2 600
550
500
450
400
3 350
3
2000 4000 6000 8000 10000 Q( m /h)

Installation Dimensional Drawing


Z Automatic coupling installation

32002700
B to
B
28
A
2711

60
720 1840

18
4107
40

2188
1800

100

1560

900
810
72

1000
800

A to 3200 Flange dimensions


pool side
6-56
900
1013 728

1050
1650

2700
1500

1115
28-34

Flange press GB/T17241.6 PN6 standard


720
1080 pool mouth

1440
1900
4016

WQ Series Submersible Sewage Pump


H(m) Performance Curve

25
Main Parameters
20
Discharge Diameter 1000mm

15 Flow Channel Motor Rated Rotating pump


Pump Type Size Power Speed weight
(mm) (kW) (r/min) (kg)
10
WQ2850-1062 313 560 590 10000

N( kW)
550
500
450

5000 7000 9000 11000 Q( m 3/ h)

Installation Dimensional Drawing


F Fixed base mounting

Flange dimensions
3300

1000
1160
2850

1230
700

28-36
300

1300 Flange press GB/T17241.6 PN6 standard


900

1450

K to

2100

1900
1010

1000
12 00
1500

4-46

850 1135

69/70
Specialists in Pumps for
More Than 20 Years.

Descriptions of Accessories
Trash screen
Based on the scale of the pump station, the diversified automatic decontamination (removal of impurities from trash screen) series are an option
for users and the dimensions are to be determined in site. The grating cleaner is shown in figure below.

1
2
70708, embedded

2500
along side width 3
4 1. Oil pressure system
2. Gantry frame
Sump top
3. Waste trolley
5 4. Traveling device
1400 5. Grab gate
Deep pool H

6. Grating bar
6 7. Safety device
8. Lifter
9. Electric control part

Sump

100

bottom

>800 200

7
8
9
4
15/kg light rail

Sump width B

Main Specification and Technical Parameters

Model Grating width (mm) Derrick(m) Grating spacing Installation Power


(mm) angle
GS
GSE -1000 1000
0.8/0.4kW
GS
(Double speed)
GSE -1250 1250 60~70, 1.1~1.5kw for
GS or 90 lifting motor,
under 0.75kW for
GSE -1500 1500 2-12 20-1000 control motor,
special
GS cases and 0.8/0.4kW
for (double-speed)
GSE -1750 1750
traveling
GS
GSE -2000 2000

WQ Series Submersible Sewage Pump


Valve

D1
DN
D2

D
n- d

Nominal Nominal bore Dimension (mm)


pressure diameter DN(mm) D D1 D2 n-d
50 165 125 102 4-18
65 185 145 122 4-18
80 200 160 133 8-18
100 220 180 158 8-18
125 250 210 184 8-18
150 285 240 212 8-22
200 340 295 268 8-22
250 395 350 320 12-22
1.0
300 445 400 370 12-22
(Mpa)
350 505 460 430 16-22
400 565 515 482 16-26
450 615 565 532 20-26
500 670 620 585 20-26
600 780 725 685 20-30
700 895 840 794 24-30
800 1015 950 901 24-33
900 1115 1050 1001 28-33

71/72
Specialists in Pumps for
More Than 20 Years.

Elbow connectors
(Two elbow connectors are available for users, one is of 0.6Mpa nominal pressure and the other is of 1.0MPa nominal pressure, and are
applicable for direct connection with the discharge flange of submersible sewage pump and for the connection with the flange of other pipeline of
same bore diameter and same nominal pressure. The user may select based on the actual flange size (DN and PN values). To prevent confusion,
please specify the specification of elbow connector at the time of ordering.)

n-d

Elbow Connectors with Flange Nominal Pressure Consistent with Pump Body Flange
Specification
of elbow a b c n-d b Flange specification L
connector
50- 6 50 110 140 4-13. 5 16 105

65- 6 65 130 160 4-13. 5 16 130

80- 6 80 150 190 4-17. 5 18 155

100- 6 100 170 210 4-17. 5 18 160


As per GB/T17241.6
150- 6 150 225 265 8-17. 5 20 PN6 (0.6MPa) 220

200- 6 200 280 320 8-17. 5 22 270

250- 6 250 335 375 12-17.5 24 320

300- 6 300 395 440 12-22 24 370

350- 6 350 445 490 12-22 26 420

400 - 10 400 515 565 16-26 32 460

450- 10 450 565 615 20-26 32 500


As per GB/T17241.6
500- 10 500 620 670 20-26 34 540
PN10(1.0MPa)
550- 10 550 675 730 20-30 35 590

600- 10 600 725 780 20-30 36 640

WQ Series Submersible Sewage Pump


Elbow Connectors in Diameter of 50-350 and in Flange Nominal Pressure of PN10 (1.0MPa)
Specification
of elbow a b c n-d b Flange specification L
connector
50 - 10 50 125 165 4-17.5 20 140

65- 10 65 145 185 4-17.5 20 160

80- 10 80 160 200 8-17.5 22 180

100- 10 100 180 220 8-17.5 24 As per GB/T17241.6 200

150- 10 150 240 285 8-22 26 PN10 230


(1.0MPa)
200- 10 200 295 340 8-22 28 280

250- 10 250 350 395 12-22 28 330

300- 10 300 400 445 12-22 28 380

350- 10 350 460 505 16-22 30 440

Hose Elbow Connectors

n-d

73/74
Specialists in Pumps for
More Than 20 Years.

Dimensional Table of Hose Elbow Connectors (Diameter of nominal pressure of flange for hose elbow connector are consistent
with those of pump body flange)

Specification
Flange Inside diameter
of hose elbow a b c n- d b L L1 e
specification of fitted hose
connector

50 - 6 50 110 140 4 - 13. 5 16 120 140 60 64

50 65 - 6 50 110 140 4 - 13. 5 16 120 140 74 76


As per GB/
65 - 6 65 130 160 4 - 13. 5 16 T17241.6 130 160 74 76
PN6
80 - 6 80 150 190 4 - 17. 5 18 (0. 6MPa) 135 190 86 89

100 - 6 100 170 210 4 - 17. 5 18 160 240 100 102

150 - 6 150 225 265 8 - 17. 5 20 220 320 150 152

Note: 1. The a of hose elbow connector is the same as bore diameter of pump, but the inside diameter of fitted hose differs
from bore diameter of the pump.
2. The pump in bore diameter of 50 can select 50-6 or 5065- 6 hose elbow connector.
3. Please specify the specification of hose elbow connector at the time of ordering.

Taper pipe
(Two taper pipes are available for the users, one is of 0.6Mpa flange nominal pressure and the other is of 1.0MPa nominal pressure, and are
applicable for direct connection with the discharge flange of submersible sewage pump, with suction flange of suction elbow under dry installation
mode, and with discharge flange of discharge pipe seat under auto-coupling installation mode and for the connection with the flange of other
pipeline of same bore diameter and same nominal pressure. The user may select based on the actual flange size (DN and PN values). To prevent
confusion, please specify the specification of taper connector at the time of ordering.)

n- d

D
1
D2

A
F

C
f

n-d1
e
E

WQ Series Submersible Sewage Pump


Cone tube D D1 D2 n-d f e A B C n-d1 F E L
specification

5065-6 50 110 140 4-13.5 90 16 65 130 160 4-13.5 110 16 100

5080-6 50 110 140 4-13.5 90 16 80 150 190 4-17.5 128 18 150

6580-6 65 130 160 4-13.5 110 16 80 150 190 4-17.5 128 18 100

80100-6 80 150 190 4-17.5 128 18 100 170 210 4-17.5 148 18 150

100150-6 100 170 210 4-17.5 148 18 150 225 265 8-17.5 202 20 250

150200-6 150 225 265 8-17.5 202 20 200 280 320 8-17.5 258 22 250

200250-6 200 280 320 8-17.5 258 22 250 335 375 12-17.5 312 24 230

250300-6 250 335 375 12-17.5 312 24 300 395 440 12-22 365 24 240

300350-6 300 395 440 12-22 365 24 350 445 490 12-22 415 26 250

( 350-6)
350 445 490 12-22 415 26 400 515 565 16-26 482 32 250
( 400-10)

400450-10 400 515 565 16-26 482 32 450 565 615 20-26 532 32 250

450500-10 450 565 615 20-26 532 32 500 620 670 20-26 585 34 250

500600-10 500 620 670 20-26 585 34 600 725 780 20-30 685 36 600

Diameter 350, the flange nominal pressure PN10 cone tube

Cone tube
D D1 D2 n-d f e A B C n-d1 F E L
specification

5065-10 50 125 165 4-17.5 102 20 65 145 185 4-17.5 122 20 150

5080-10 50 125 165 4-17.5 102 20 80 160 200 8-17.5 133 22 150

6580-10 65 145 185 4-17.5 122 20 80 160 200 8-17.5 133 22 150

80100-10 80 160 200 8-17.5 133 22 100 180 220 8-17.5 158 24 150

100150-10 100 180 220 8-17.5 158 24 150 240 285 8-22 212 26 250

150200-10 150 240 285 8-22 212 26 200 295 340 8-22 268 28 250

200250-10 200 295 340 8-22 268 28 250 350 395 12-22 320 28 250

250300-10 250 350 395 12-22 320 28 300 400 445 12-22 370 28 250

300350-10 300 400 445 12-22 370 28 350 460 505 16-22 430 30 250

350400-10 350 460 505 1 6-22 430 30 400 515 565 16-26 482 32 250

75/76
www.kaiquangroup.com

Address : No.4255 Caoan Road.Shanghai Post Code: 201804 Service Center: +86-21-6959 3241
Overseas Department: +86-21-5651 4775 E-mail: Trading@kaiquan.com.cn

Вам также может понравиться