Вы находитесь на странице: 1из 4

Contactors, Relays, Starters

Starters
2. Type designation
NQ3- P

Code of structure characteristic:


P means with buttons

Code of power grade of the bracket

NQ3 Design code name

DOL Electromagnetic Starter


1. General
1.1 NQ3 series electromagnetic starter
( "starter" for short hereinafter) applies mainly to
circuit with AC current of 50Hz (or 60Hz),
rated operational voltage of 660V
and rated controlled power up to 11kW
Electromagnetic starter
(current up to 22A)
for using to control the direct start
and halt of the electromotor to protect the motor
from overload and phase failure.
1.2 The starter conforms to standards IEC/EN60947-4-1

Characteristic code of the enterprise

3. Technical data
Altitude: not exceeding 2000m;
Temperature of ambient air: -5~+40
Rated control supply voltage (AC 50Hz):
24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V
Mechanical life: 1,000,000 circles;
Electric life: 500,000 circles;
IP55

F-15 > >>


Contactors, Relays, Starters
Starters
Table 1 Basic Model and main technical parameter of the starter

Maximum rated Power (kW) Model of Range of


Rated working
Model AC-3 equipped TOR matched setting current
current (A)
AC contactor A
660V 380V 220V

0.1~0.16

0.16~0.25

0.25~0.4

0.4~0.63

0.63~1
NQ3-5.5P 12 7.5 5.5 3 NC1-1810 NR2-25
1~1.6

1.25~2

1.6~2.5

2.5~4

4~6
F
5.5~8

7~10

9~13

NQ3-11P 22 15 11 5.5 NC1-3210 12~18

17~25

4. Overall and mounting dimension (mm)

NQ3-5.5P

NQ3-5.5P

Ie A spec sign

0.1
0.1 60.2
60.2 5
5 0.6
0.63 1 START
31
1.2 2
5
4
4 6
8
166max

7 10
130

9 13
12 18
17 25 STOP
Rated Voltage V 50Hz spec sign

36
110
220
380

Standard EN60947-4-1
IEC60947-4-1
degree of protection IP55
ZHEJIANGCHINTELECTRICSCO.,LTD

125max 60
36
96max

> >> F-16


Contactors, Relays, Starters
Starters
NQ3-11P

NQ3-11P

Ie A specsign

0.6 1
31
1.2 2
5
4
196max

4 6

150
8
7 10
9 13
12 18
17 25
23 32

Rated Voltage V 50Hz specsign

36
110
220
380

Standard EN60947-4-1
IEC60947-4-1
degree of protection
IP55

ZHE JIANG CHINT ELECTRICSCO.,LTD

130max 60
116max 36

5. Wiring Diagram

L1 L3 L5 L1 L3 L5
FU1 FU1
connect to other supply

1 3 5 1 3 5
FR
KM FR KM
2 4 6 2 4 6
1 3 5 A1 1 3 5 A1
FR KM KM FR KM KM
2 4 6 A2 A2
2 4 6
U V W U V W

M M

Control supply voltage is as the same as Control supply voltage is not as the same as
the main circuit voltage (three-phrase) the main circuit voltage (three-phrase)

L N L N
FU1 FU1
Connect to other supply

1 3 5 1 3 5
FR FR
KM KM
2 4 6 2 4 6
1 3 5 A1 1 3 5 A1
FR KM FR KM
KM KM
2 4 6 A2 2 4 6 A2
U1 U2 U1 U2

M M

Control supply voltage is as the same as Control supply voltage is not as the same as
the main circuit voltage (single-phrase) the main circuit voltage (single-phrase)

F-17 > >>


Contactors, Relays, Starters
Starters
6. Picture
NQ3-5.5P

NQ3-11P

> >> F-18

Вам также может понравиться