Вы находитесь на странице: 1из 3

1005195 04-1005195_J

J
1B2A3NA4B5A6A7A8 C
C132 shay shay Maint Plea JJibCrane
eInspecttion
M
Maintena anceRepport
04-1005195
1300 7611 822

JobNo. J1610688
Client C1321
- Haynes Mechanical Datte 02/06/17

No. NQC1154
LibraryN Details#4 Jib c/w Chain Hoist Demag 1T
CraneD RC(t) 1 EquipmentID
Purchase
eOrderNo. WorkOrderNo.. TBA
SerrviceCarriedOut 3 Monthly

ailsHMC
SiteDeta Workshop

esTake5 Yes
NQCrane N
NQCranesJSA Clien
ntequivalentsafe
etyassessment

I/Wedecclarethattheabovvesafetyassessmentswereconductedpriortothecoommencementoftheseworks:
X

AInspecctedNoActionreq
quired,BAdjustmen
nts/RepairsMade,C
CAdditionalRepairssRequired,DUrgen
ntRepairsRequired
d,EWARNINGDO
ONOTUSE!,NANottApplicable,IImageebelow

GeneralCondition A B C D E NA Comment I
1.GeneraalConditionandCCleanliness Hoist is 13 years old - recommend major overhaul/replacing hoist not working
2.PreOpperationalLogBoook
AccessPla atformsandLaddeers A B C D E NA Comment I
3.AdequateandClean
Pendant//RadioControls A B C D E NA Comment I
4.Housinng Pendent too old recommend replacing
5.ButtonnsandSwitches
6.CableaandStrainerCablee
7.Legendds Pendent cable too old-recommend replacing
8.EmergencyStop
CrossCate enary A B C D E NA Comment I
9.TrackssandSupports C- track bent at the end,still sarvicable
10.Trolleys
11.Travelling"J"Box
12.Cabless
13.TowA Arm
Structure A B C D E NA Comment I
14.Conne ectionsBolts/Welds
17.Bufferrs
18.Guard dsandCovers
19.GenerralStructureandW Welds
20.RatedCapacity(RC)Sign nage
21.Identification(ID)Signage
22.Comp passSignage
23.Clearaance
24.LimitSStrikers
Electrics A B C D E NA Comment I
25.ElectricalSchematics
26.MainIsolatorandSign
27.AccesstoMainIsolator
28.ServicceIsolatorsandSiggns
29.ControlPanelEnclosurees
30.ContaactorsandOverloaads
31.GenerralWiring Hoist not working
32.Lightinng
33.WarningSirensandLigh hts
34.SoftStartersResistorsVFDrive
35.LoadIIndicator
Hoist A B C D E NA Comment I
50.GenerralCondition Hoist not working
51.HookandSafetyCatch
52.SheavvesandPins
53.Guard ds
54.RopeorChainCondition n Could not inspect chain- hoist not working
55.RopeChainGuides
56.RopeDrum
57.Lubriccation
58.Gearb boxandOil
59.MotorandBrake Hoist not working
60.DeadEndandAnchorP Point
61.ChainBucket
62.ShaftssandCouplings
63.WorkiingLimits
64.UpperrFinalLimit
65.LoadLLimiter


A.B.N.2
20060375699 www
w.nqcranes.com..au Pagee1 of3

Jib Crane Inspection


Maintenance Report
04-1005195
1300 761 822

A Inspected - No Action required, B Adjustments/Repairs Made, C Additional Repairs Required, D Urgent Repairs Required, E WARNING - DO NOT USE!, NA Not Applicable, I Image below

Trolley / Crab A B C D E NA Comment I


66. General Condition
67. Service Isolator and Signs
68. Wheels and Bearings
69. Ring Gears and Pinions
70. Anti-Derailment / Anti-Capsize
71. Lubrication
72. Gearbox and Oil
73. Motor and Brake
74. Shafts
75. Transmission Couplings and Keys
76. Limits
77. Buffers
Slew Travel A B C D E NA Comment I
94. General Condition Slew not holding position -recommend adjusting friction plate bolt
95. Wheels, Bearings and Bushes
96. Rings Gears and Pinions
97. Anti-Capsize
98. Lubrication
99. Gearbox and Oil
100. Motor and Brake
101. Limits and Clutches
102. Torque Arm Attachments
103. Storm Anchors
Functional Test A B C D E NA Comment I
90. Raise and Lower Hoist not working
92. Cross Travel
93. Swing / Slew Not holding position

Comments

LSR/Hour Meter Reading: Also performed during this service (tick): Earth Continuity Check Load Test

Part No. Description Qty Store Technician Hours

Other Equipment Used

Access Equipment 8m Scissor Supplied By NQCranes

A.B.N. 20 060 375 699 www.nqcranes.com.au Page 2 of 3


Jib Crane Inspection
Maintenance Report
04-1005195
1300 761 822

Image 1. Image 2. Image 3.

Image 4. Image 5. Image 6.

Certificate of Test I hereby certify that any electrical installation work listed above has been tested in accordance with the prescribed procedures and that such work
complies with the requirements of Section 227 (3) Electrical Safety Regulation 2013. | Electrical Contractors License Number. 65624

The equipment has been function tested and at the time of service is in operational condition: No Job Complete: No Repairs Quote Required: No

Notes: 1. This report is made following visual inspection only of the equipment in accordance with AS2550.3-2002
2. No responsibility will be taken for unseen internal condition of components
3. Resultant repair work will only be conducted following authorization from the equipment owner
4. This docket should be kept as a record of inspection as required by government legislation

Serviced By (Name): Ernest Manyuchi Customer Name: Job Summary 72-1722

X X

On completion a copy of this report will be emailed to shayne@haynesgroup.com.au Additional Email Address:

A.B.N. 20 060 375 699 www.nqcranes.com.au Page 3 of 3

Вам также может понравиться