CIVIL ENGINEERING DEPARTMENT

Subject: Structural Design and Drawing III Tutorial No: - T04

Date: 16 August 2017 Due Date: - 24 August 2017

Faculty: - Dr. Swapnil B. Kharmale

Design and Detailing of Intermediate Continuous Beam of Portal Frame


Design Problem-1

The plan and elevation of a G+2 storey school building is shown in figure below. The lateral load
resisting system of this building is SMRF in RCC.

B2 A B C

B1

B2 B2
L1 L2
Y SECTIONAL ELEVATION YY

Analyse the special moment resisting frame as shown in sectional elevation Y-Y using seismic coefficient
method. (Assume that frame is without brick infill)

Analyse the first floor beam ABC for combined effect of gravity and lateral loads for 1.2 (DL+LL+EQ)
combination mentioned in IS: 1893 using appropriate approximate method of analysing portal frames

Design the first floor beam ABC using 15 % redistribution of moment as per IS:456

Detail the design of same beam on a full imperial drawing sheet


Use following data per Group

Group
No.
I II III IV V VI VII VIII IX X XI XII XIII XIV XV XVI
Data

L1 (m) 5.50 5.75 6.25 6.50 5.50 5.75 6.25 6.50 5.50 5.75 6.25 6.50 5.50 5.75 6.25 6.50
L2( m) 5.50 5.75 6.25 6.50 5.50 5.75 6.25 6.50 5.50 5.75 6.25 6.50 5.50 5.75 6.25 6.50
B1 (m) 4.75 5.00 5.25 5.25 4.75 5.00 5.25 5.25 4.75 5.00 5.25 5.25 4.75 5.00 5.25 5.25
B2 (m) 3.75 4.00 4.25 4.25 3.75 4.00 4.25 4.25 3.75 4.00 4.25 4.25 3.75 4.00 4.25 4.25
Ahmada Guwa hat
Location Delhi Mumbai Ba na ras Sri naga r Pune Jaipur Chennai Kochi Nagpur Nashik Kanpur Lucknow Noida Agra
bad i
Soil Type Soft Ha rd Medium Medium Soft Ha rd Ha rd Ha rd Soft Soft Medium Medium Ha rd Soft Soft Ha rd
Dead
Load on
5.25 5.00 4.75 4.50 5.25 5.00 4.75 4.50 5.25 5.00 4.75 4.50 5.25 5.00 4.75 4.50
Floor
(kN/m2)
Dead
Load on
Hal f to tha t on floor
Roof
(kN/m2)
Live Load
on Floor 4.25 4.00 3.75 3.50 4.25 4.00 3.75 3.50 4.25 4.00 3.75 3.50 4.25 4.00 3.75 3.50
(kN/m2)
Live Load
on Roof Hal f to tha t on floor
(kN/m2)
Grade of
M25 M20 M20 M30 M25 M20 M20 M30 M25 M20 M20 M30 M25 M20 M20 M30
Concrete
Grade of
Fe 250 Fe 415 Fe 415 Fe 500 Fe 250 Fe 415 Fe 415 Fe 500 Fe 250 Fe 415 Fe 415 Fe 500 Fe 250 Fe 415 Fe 415 Fe 500
Steel

Soft Computing Problem-1

Use free source RISA 2D (Educational Version) to analyse the frame and compare the analysis results with those obtained by approximate methods, Attach
the print outs of results and comparison of results by both approximate method and RISA 2D software for 1) BMD of whole frame under lateral load 2) BMDs
for various loading arrangement cases for Beam ABC under gravity loads.