BASIC STATION - 24VAC VALVES

NAME CODE DESCRIPTION

FERTIGROW-C1 168051 FERTIGROW POWER SUPPLY 230VAC


Includes 24VAC control outputs for:
1 Output for irrigation pump
4 Outputs for fertilizer dosage valves
1 Output for acid dosage solenoid valve
10 Outputs for irrigation valves

Includes inputs for:


1 EC measurement with temperature adjustment
1 pH measurement
1 Irrigation flow rate measurement
1 Solar radiation measurement
1 Air temperature measurement
1 Air humidity measurement

N.B. Sensors are not included.

FERTIGROW box can contain up to 2 expansion boards of 10 valves each.

FERTIGROW-C2 168052 FERTIGROW POWER SUPPLY 115VAC


Includes 24VAC control outputs for:
1 Output for irrigation pump
4 Outputs for fertilizer dosage valves
1 Output for acid dosage solenoid valve
10 Outputs for irrigation valves

Includes inputs for:


1 EC measurement
1 pH measurement
1 Irrigation capacity measurement
1 Solar radiation measurement
1 Air temperature measurement
1 Air humidity measurement

N.B. Sensors are not included.

FERTIGROW box can contain up to 2 expansion boards of 10 valves each.

EXPANSION BOX - 24VAC VALVES

NAME CODE DESCRIPTION

EXPANSIONBOX-S-C1 168045 EXPANSION-BOX POWER SUPPLY 230VAC- WITHOUT VALVE BOARDS

In each EXPANSIONBOX-S-C1 box you can install up to 2 expansion boards of


10 FLEXIO-REL10 valves each.

EXPANSIONBOX-M-C1 168047 EXPANSION-BOX POWER SUPPLY 230VAC- WITHOUT VALVE BOARDS

In each EXPANSIONBOX-M-C1 box you can install up to 8 expansion boards of


10 FLEXIO-REL10 valves each.

EXPANSIONBOX-S-C2 168046 EXPANSION-BOX POWER SUPPLY 115VAC-WITHOUT VALVE BOARDS

In each EXPANSIONBOX-S-C2 box you can install up to 2 expansion boards of


10 FLEXIO-REL10 valves each.

EXPANSIONBOX-M-C2 168048 EXPANSION-BOX POWER SUPPLY 115VAC-WITHOUT VALVE BOARDS

In each EXPANSIONBOX-M-C2 box you can install up to 8 expansion boards of


10 FLEXIO-REL10 valves each.

EC MEASUREMENT AND SETTING BOARD

NAME CODE DESCRIPTION

PROSENS-ECKIT+ATT. 168064 KIT FOR THE MEASUREMENT AND SETTING OF EC.

Contains:

Conversion electronic board to be inserted in the CPU main board inside


FERTIGROW box.

Probe for the measurement of EC with temperature sensor.


Cable length: 4 m, 1 male threaded

16
pH MEASUREMENT AND SETTING BOARD

NAME CODE DESCRIPTION

PROSENS-PHKIT+ATT. 168065 KIT FOR THE MEASUREMENT AND SETTING OF pH.

Contains:

Conversion electronic board to be inserted in the CPU board inside


FERTIGROW box.

Glass pH probe with electrode holder, maximum pressure 8 bar, cable


length: 1,5 m, 1 male threaded

10-VALVES EXPANSION BOARD

NAME CODE DESCRIPTION

FLEXIO-REL10 EAP0128 EXPANSION BOARD FOR 10 VALVES

In FERTIGROW basic station you can install up to 2 FLEXIO-REL10 boards

In the EXPANSIONBOX-M box you can install up to 8 FLEXIO-REL10 boards

In the EXPANSIONBOX-S box you can install up to 2 FLEXIO-REL10 boards

SOLAR RADIATION SENSOR

NAME CODE DESCRIPTION

TINYMETEO-RADV+ATT. 167106 RADIATION SENSOR + ACTIVATION


Sensor for the measurement of solar radiation intensity
7 m cable supplied
Ready-to-install on TINYMETEO-MOUNT3 and TINYMETEO-MOUNT5 meteo
station
Connection with 2 wires
Needs 1 analogical input 0-1V

TEMPERATURE AND HUMIDITY SENSOR

NAME CODE DESCRIPTION

CLIMASENS-ATRH2- 167090 AIR TEMPERATURE AND HUMIDITY ELECTRONIC SENSOR + PROTECTION


PROT+ATT. + ACTIVATION
1,5 m cable supplied
Connection with 4 wires
Needs 2 analogical inputs 0-1V

N.B. 1 sensor maximum

WOLTMANN FLOW SENSOR

Needs 1 digital input


NAME DESCRIPTION CODE
PROSENS-WFLOW-DN50+ATT WOLTMANN FLOW SENSOR DN50+ACTIVATION 167099
PROSENS-WFLOW-DN65+ATT WOLTMANN FLOW SENSOR DN65+ ACTIVATION 167100
PROSENS-WFLOW-DN80+ATT WOLTMANN FLOW SENSOR DN80+ ACTIVATION 167101
PROSENS-WFLOW-DN100+ATT WOLTMANN FLOW SENSOR DN100+ ACTIVATION 167102
PROSENS-WFLOW-DN125+ATT WOLTMANN FLOW SENSOR DN125+ ACTIVATION 167103
PROSENS-WFLOW-DN150+ATT WOLTMANN FLOW SENSOR DN150+ ACTIVATION 167104
PROSENS-WFLOW-DN200+ATT WOLTMANN FLOW SENSOR DN200+ ACTIVATION 167105

17
ACCESSORIES FOR GPRS RADIO COMMUNICATION

GPRS CARD + ANTENNA + ACTIVATION


FLEXMOD-GPRS+ATT. 167092
Thanks to this card you can use MCSMS and MCWEB services.

MC-WEB SERVICE

6 month user licence to web supervision software for one controller /


computer.
MCWEB-6MONTHS-FULL SFT0030
N.B. To let the service function you need to install the GPRS card with the
relative antenna (art. 167092).

12 month user licence to web supervision software for one controller /


computer.
MCWEB-12MONTHS-FULL SFT0031
N.B. To let the service function you need to install the GPRS card with the
relative antenna (art. 167092).

ACCESSORIES FOR PC COMMUNICATION

BUS-USB-ISO RS485 / USB isolated converter EAP0544

MCNET-HYDRO MCNET supervision software user licence for 1 client station. SFT0011

BUS PROTECTIONS

BUS-PROT-ISO BUS PROTECTION DISCHARGER + ISOLATOR EAP0543

BUS-PROT BUS PROTECTION DISCHARGER EAP0566

18
FERTIGROW SYSTEM POWER CONNECTIONS

FERTIGROW EXPANSION-BOX
pH measurement

EC measurement

24VAC valves
24VAC valves

Control of
4 valves for fertilizer
dosage and
1 valve for acid
dosage
230VAC/ 230VAC/
115VAC 115VAC

Flow sensor

Radiation
sensor
Pump control

Temperature Optional in case of


BUS-PROT BUS-PROT
and humidity long distances
sensor
BUS-PROT

UTP twisted pare cable


maximum length 1000 meters
N.B. Radiation, temperature and flow sensors can be connected to
EXPANSIONBOX boxes too.

TELECONTROL AND INTERNET SUPERVISION

MCSMS telecontrol
Constant control of the system
Irrigation
line 2:
FLEXMOD-GPRS card
pression
lowering

MCWEB supervision
A range of services to control your company
wherever you are
See SIM card
COMMUNICATION
catalogue

19
LOCAL TELECONTROL

MCNET supervision software


Global control

BUS-USB-ISO
CONVERTER

See SUPERVISION
catalogue

FERTIGROW SPECIFICATIONS

Power supply: 220VAC + earth (IRRIGROW-C1)


115VAC + earth (IRRIGROW-C2)
Standard over tension protection included
Power: 0.2 KW
Weight: 10 Kg (box only, excluding sensors and
accessories)
Ingress protection rating: IP65
Working temperature range: -15 C +50 C
Size: Height: 42,5 cm
Length: 32,5cm
Depth: 18,5 cm
Cable passageways: N. 5 strain relieves PG21
Including 4 caps for the closure of unused
strain relieves
User interface: Retro-illuminated graphic display
24 keys keyboard
Selectable language
Password protection
Other specifications: Supplied with wall mount brackets
Connection to UTP twisted pair cable cat.5 needed for
supervision PC: serial link from controller to PC. Maximum
cable length 1000 m.
free I/O available: 20 24VAC outputs
5 digital inputs
4 analogical inputs 0-1V / 0-20mA
1 analogical output 4-20mA

EXPANSIONBOX-S SPECIFICATIONS

See page 108

EXPANSIONBOX-M SPECIFICATIONS