Вы находитесь на странице: 1из 8

LOAD COMPUTATION FOR RESIDENTIAL

Residential Load Type A


Total Maximum Demand 11 903.33 VA

Residential Load Type B


Total Maximum Demand 10 253.33 VA

Residential Load Type C


Total Maximum Demand 8293.33 VA

Residential Load Type D


Total Maximum Demand 7325.33 VA

Residential Load Type E


Total Maximum Demand 5325.33 VA

Residential Load Type A

Area= 150 SQ. MTS.


Maximum Expected General Lighting Load
=Area x 24 VA per SQ. MTS. 3600 VA

General Lighting Load:

6 Fluorescent Lamp (48 W) 288 VA


3 Incandescent Bulb (50 W) 150 VA
2 Chandelier (100 W) 200 VA
10 Pinlight (10 W) 100 VA
2 Circular Lamp (24 W) 48 VA
786 VA
Small Appliance Load:

2 Television Set 24 (100 W) 200 VA


1 Personal Computer (200 W) 200 VA
3 Electric Stand Fan (75 W) 225 VA
1 Flat Iron (1 000 W) 1 000 VA
1 Vacuum Cleaner (100 W) 100 VA
1 DVD Set (75 W) 75 VA
1 800 VA
General Power Service:

2 1.0 HP Air Conditioning Unit (ACU)


At 8A (1840 W) 3 680 VA
1 1/6 HP Refrigerator (124.33 W) 124.33 VA
1 1.0 HP Water Pump
At 8A (1840 W) 1 840 VA
1 Electric Range (3000 W) 3 000 VA
1 Washing Machine (186.5 W) 186.5 VA
1 Clothes Dryer (186.5 W) 186.5 VA
9 017.33VA

Total Maximum Demand 11 003.33 VA

Residential Load Type B

Area= 130 SQ. MTS.


Maximum Expected General Lighting Load
=Area x 24 VA per SQ. MTS. 3120 VA

General Lighting Load:

6 Fluorescent Lamp (48 W) 288 VA


2 Incandescent Bulb (50 W) 100 VA
1 Chandelier (100 W) 100 VA
8 Pinlight (10 W) 80 VA
2 Circular Lamp (24 W) 48 VA
616 VA
Small Appliance Load:

2 Television Set 24 (100 W) 200 VA


1 Personal Computer (200 W) 200 VA
3 Electric Stand Fan (75 W) 225 VA
1 Flat Iron (1 000 W) 1 000 VA
1 Vacuum Cleaner (100 W) 100 VA
1 DVD Set (75 W) 75 VA
1 800 VA
General Power Service:

1 1.5 HP Air Conditioning Unit (ACU)


At 10A (2300 W) 2300 VA
1 1/6 HP Refrigerator (124.33 W) 124.33 VA
1 1.0 HP Water Pump
At 8A (1840 W) 1 840 VA
1 Electric Range (3000 W) 3 000 VA
1 Washing Machine (186.5 W) 186.5 VA
1 Clothes Dryer (186.5 W) 186.5 VA
7637.33VA

Total Maximum Demand 10 053.33 VA

Residential Load Type C

Area= 125 SQ. MTS.


Maximum Expected General Lighting Load
=Area x 24 VA per SQ. MTS. 3000 VA

General Lighting Load:

6 Fluorescent Lamp (48 W) 288 VA


3 Incandescent Bulb (50 W) 150 VA
8 Pinlight (10 W) 80 VA
2 Circular Lamp (24 W) 48 VA
566 VA
Small Appliance Load:

1 Television Set 24 (100 W) 100 VA


1 Personal Computer (200 W) 200 VA
3 Electric Stand Fan (75 W) 225 VA
1 Flat Iron (1 000 W) 1 000 VA
1 DVD Set (75 W) 75 VA
1 600 VA
General Power Service:

1 1.0 HP Air Conditioning Unit (ACU)


At 10A (1840 W) 1 840 VA
1 1/6 HP Refrigerator (124.33 W) 124.33 VA
1 1.0 HP Water Pump
At 8A (1840 W) 1 840 VA
1 Electric Range (3000 W) 3 000 VA
1 Washing Machine (186.5 W) 186.5 VA
1 Clothes Dryer (186.5 W) 186.5 VA
7177.33 VA

Total Maximum Demand 9343.33 VA

Residential Load Type D

Area= 120 SQ. MTS.


Maximum Expected General Lighting Load
=Area x 24 VA per SQ. MTS. 2880 VA

General Lighting Load:

6 Fluorescent Lamp (48 W) 288 VA


5 Incandescent Bulb (50 W) 250 VA
538 VA
Small Appliance Load:

1 Television Set 24 (100 W) 100 VA


1 Personal Computer (200 W) 200 VA
3 Electric Stand Fan (75 W) 225 VA
1 Flat Iron (1 000 W) 1 000 VA
1 DVD Set (75 W) 75 VA
1 600 VA
General Power Service:
1 1.0 HP Air Conditioning Unit (ACU)
At 10A (1840 W) 1 840 VA
1 1/6 HP Refrigerator (124.33 W) 124.33 VA
1 1.0 HP Water Pump
At 8A (1840 W) 1 840 VA
1 Washing Machine (186.5 W) 186.5 VA
1 Clothes Dryer (186.5 W) 186.5 VA
4 177.33 VA

Total Maximum Demand 6315.33 VA

Residential Load Type E

Area= 110 SQ. MTS.


Maximum Expected General Lighting Load
=Area x 24 VA per SQ. MTS. 2640 VA

General Lighting Load:

6 Fluorescent Lamp (48 W) 288 VA


4 Incandescent Bulb (50 W) 200 VA
488 VA
Small Appliance Load:

1 Television Set 24 (100 W) 100 VA


1 Personal Computer (200 W) 200 VA
4 Electric Stand Fan (75 W) 300 VA
1 Flat Iron (1 000 W) 1 000 VA
1 600 VA
General Power Service:

1 1.0 HP Air Conditioning Unit (ACU)


At 10A (1840 W) 1 840 VA
1 1/6 HP Refrigerator (124.33 W) 124.33 VA
1 Micro Oven (100 W) 100 VA
1 Washing Machine (186.5 W) 186.5 VA
1 Clothes Dryer (186.5 W) 186.5 VA
2437.33 VA

Total Maximum Demand 4525.33 VA

FORM 1: RESIDENTIAL LOADS


FEEDER 1

MAXIMUM DEMAND FACTOR OF EACH TYPE OF TRANSFORMER. AT 85% PF

TYPE & NO. OF MAXIMUM G.L.L. DEMAND MAXIMUM


CUSTOMER & S.A.L. GENERAL POWER EXPECTED
(X) SERVICE DEMAND PER NO.
(G.L.L.+S.A.L.)(0.72) (Y) OF CUSTOMER
3.5 (GPS)(0.85) (KVA)
(0.72)(1.5) X+Y
0.85
A 531.97 8660.03 9192
2A 1 063.94 17320.06 18384
3A 1 595.91 25980.09 27576
4A 2 127.88 34640.12 36768
5A 2 659.85 43300.15 45960
B 497.00 6010.86 6507.86
2B 994.00 12021.72 13015.72
3B 1491.00 18032.58 19523.58
4B 1988.00 24043.44 26031.44
5B 2485.00 30054.30 32539.3
C 445.58 5648.82 6094.4
2C 891.16 11297.64 12188.8
3C 1336.74 16946.46 18283.2
4C 1782.32 22595.28 24377.6
5C 2227.90 28244.10 30472
D 439.82 3287.71 3727.53
2D 879.64 6575.42 7455.06
3D 1319.46 9863.13 11182.59
4D 1759.28 13150.84 14910.12
5D 2199.10 16438.55 18637.65
E 429.53 1918.27 2347.8
2E 859.06 3836.54 4695.6
3E 1288.59 5754.81 7043.4
4E 1718.12 7673.08 9391.2
5E 2147.65 9591.35 11739