5.- DYNSIM Modelling: Equipment and Streams
IPS Confidential 2
DYNSIM Equipment
Models
Pressure Nodes
Flow Devices
IPS Confidential
DYNSIM Pressure Nodes
IPS Confidential 4
Pressure Nodes: Common Features
IPS Confidential 5
Pressure Nodes: Equipment Connection
In DYNSIM, Pressure Node devices and equipment can not
be connected together. There must be at least one Flow
Device object connecting pressure nodes
IPS Confidential 6
DYNSIM Flow Devices
Valve Expander
Relief Valve Heat Exchanger
Pipe Utility Exchanger
Centrifugal Combustor
Compressor
Fired Heater
Reciprocating (Pipe Side)
Compressor
Multi Exchanger
Pump
Stream Set
Slate Change
Single input and single output
IPS Confidential
Can leave models unconnected 7
Flow Devices Common Features
W J P R MASS
IPS Confidential 8
Flow Devices: Equipment Connection
IPS Confidential 9
DYNSIM Streams
Stream Types
Process Stream Structure
Flow Device Properties Calculations
IPS Confidential
Stream Types
Process Streams
Enthalpy based, not temperature based
Mechanical Streams
Connect rotating equipment
Heat Streams
Connect utility exchanger
Electrical Streams
Connect current and voltage
Note that Controls are connected by parameter connections (when
graphical) or references, not streams
In DYNSIM Power, stream are not drawn most of the times, just the
reference is added to the object (OEV)
IPS Confidential 11
Stream Types
IPS Confidential 12
Stream Bi-Directional Data Transfer
Resistance Capacitance
calc flux calc potential
Flow
Process: Flow Device Pressure Node
Pressure
Power
Mechanical: Rotating Equip Shaft/Motor
Speed
Duty
Heat: Utility Exchanger Drum
Temperature
Current
Electrical: Motor Bus
Voltage
IPS Confidential 14
Reverse Flow and Continuity
Continuity is a simple method to calculate stream parameters
If accurate temperature dynamics is required between valves, add a
pipe model with holdup
H1.FLASH.T 400 C H1.FLASH.T 300 C
Flow device flashes are the
same as the outlet streams. H1 H2
S1.T S2.T
Forward Flow 400 C 400 C
Reverse Flow 300 C 300 C
Zero Flow Valve Open 350 C 350 C
Zero Flow Valve Closed 400 C 300 C
IPS Confidential 15
Flow Device Properties Calculations
Flow devices set their outlet stream properties. By default
most flow devices set outlet properties equal to inlet
properties
V1 V2
S1 S2 S3
Thank You