Вы находитесь на странице: 1из 134

Handover Control (GHandoverControl) Page 1 of 134

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 2 of 134

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 3 of 134

Handover Control (GHandoverControl)

This section includes the following information:

Handover Control ID
Uplink power level Sample count
Uplink level Weight
Downlink power level Sample count
Downlink level Weight
Uplink quality Sample count
Uplink quality Weight
Downlink quality Sample count
Downlink quality Weight
Distance
Neighboring cell
Number of zero allowed in AV
MIN interval between inter-cell handover
Max time advance threshold between MS and BTS
Uplink receive level Threshold
Downlink receive level Threshold
Uplink receive quality Threshold
Downlink receive quality Threshold
Uplink receive level of intra-ho Threshold
Downlink receive level of intra-ho Threshold
Uplink receive level Value P
Uplink receive level Value N
Downlink receive level Value P
Downlink receive level Value N
Uplink receive quality Value P
Uplink receive quality Value N
Downlink receive quality Value P
Downlink receive quality Value N
Uplink receive level of intra-ho Value P
Uplink receive level of intra-ho Value N
Downlink receive level of intra-ho Value P
Downlink receive level of intra-ho Value N
Distance handover Value P
Distance handover Value N
PBGT handover Value P
PBGT handover Value N
Allow intra-Cell handover attempt due to uplink interference(High Speed)
Allow intra-Cell handover attempt due to downlink interference(High Speed)
Allow handover due to distance(High Speed)
Allow standard PBGT handover(High Speed)
Allow automatic handover due to traffic(High Speed)
Allow intra-cell handover in super TRX channel due to downlink interference(High Speed)
Allow intra-cell handover in super TRX channel due to uplink interference(High Speed)
Allow adjacent cells handover in super TRX channel due to PBGT(High Speed)
Allow rapid handover(High Speed)

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 4 of 134

Allow Macro-Micro delay handover(High Speed)


Allow Micro-Micro delay handover(High Speed)
Allow force transfer handover(High Speed)
Allow quality handover in uplink(High Speed)
Allow level handover in uplink(High Speed)
Allow quality handover in downlink(High Speed)
Allow level handover in downlink(High Speed)
Allow downlink rapid handover(High Speed)
Allow C/I limited handover(High Speed)
Allow downlink quality rapid handover(High Speed)
Allow intra-Cell handover attempt due to uplink interference(Middle Speed)
Allow intra-Cell handover attempt due to downlink interference(Middle Speed)
Allow handover due to distance(Middle Speed)
Allow standard PBGT handover(Middle Speed)
Allow automatic handover due to traffic(Middle Speed)
Allow intra-cell handover in super TRX channel due to downlink interference(Middle Speed)
Allow intra-cell handover in super TRX channel due to uplink interference(Middle Speed)
Allow adjacent cells handover in super TRX channel due to PBGT(Middle Speed)
Allow rapid handover(Middle Speed)
Allow Macro-Micro delay handover(Middle Speed)
Allow Micro-Micro delay handover(Middle Speed)
Allow force transfer handover(Middle Speed)
Allow quality handover in uplink(Middle Speed)
Allow level handover in uplink(Middle Speed)
Allow quality handover in downlink(Middle Speed)
Allow level handover in downlink(Middle Speed)
Allow downlink rapid handover(Middle Speed)
Allow C/I limited handover(Middle Speed)
Allow downlink quality rapid handover(Middle Speed)
Allow intra-Cell handover attempt due to uplink interference(Low Speed)
Allow intra-Cell handover attempt due to downlink interference(Low Speed)
Allow handover due to distance(Low Speed)
Allow standard PBGT handover(Low Speed)
Allow automatic handover due to traffic(Low Speed)
Allow intra-cell handover in super TRX channel due to downlink interference(Low Speed)
Allow intra-cell handover in super TRX channel due to uplink interference(Low Speed)
Allow adjacent cells handover in super TRX channel due to PBGT(Low Speed)
Allow dynamic adjustment of handover priority
Allow rapid handover(Low Speed)
Allow Macro-Micro delay handover(Low Speed)
Allow Micro-Micro delay handover(Low Speed)
Allow force transfer handover(Low Speed)
Allow quality handover in uplink(Low Speed)
Allow level handover in uplink(Low Speed)
Allow quality handover in downlink(Low Speed)
Allow level handover in downlink(Low Speed)
Allow downlink rapid handover(Low Speed)
Allow C/I limited handover(Low Speed)
Allow downlink quality rapid handover(Low Speed)

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 5 of 134

Synchronism
Asynchronism
Pseudo-synchronism
Pre-synchronism
Prior layer selecting parameter on signal level/quality
Rapid handover Threshold
Rapid handover Value N
Handover to same layer other band neighbour cell for PBGT permitted
Handover to neighbour cell with no Layer Relation for PBGT permitted
Handover to upper layer neighbour cell for PBGT permitted
Handover to under layer neighbor cell for PBGT permitted
Penalty time for handover failure
Difference of dynamic priority
PBGT difference
Same layer permitted on traffic HO
Upper layer permitted on traffic HO
Lower layer permitted on traffic HO
Undefined layer permitted on traffic HO

GSM900 frequency band P-GSM

permitted on traffic HO

EXT900 frequency band E-GSM permitted on traffic HO


DCS1800 frequency band permitted on traffic HO
PCS1900 frequency band permitted on traffic HO
GSM850 frequency band permitted on traffic HO
Threshold of traffic for handover
Traffic handover threshold
Level offset during penalty
Uplink interference quality offset
Uplink interference level offset
Downlink interference quality offset
Downlink interference level offset
Invalid intra-handover time
MAX count of invalid intra-handover
MAX path loss threshold on force handover
MAX time advance threshold on force handover
N value of force handover
P value of force handover
Level offset for PBGT to up layer
Level offset for PBGT to low layer
Lag time for PBGT between different layers
The threshold for starting PBGT handover
The priority of the handover from Macro cell to Micro cell
Handover from macro to micro
Hysteresis timer when traffic handover
Downlink rapid handover offset of high speed
Downlink rapid handover offset of middle speed
Downlink rapid handover offset of low speed
Handover back penalty

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 6 of 134

MIN interval between inter-cell emergency handover


Handover back penalty after emergency handover
Neighbour cell for emergency handover
Downlink rapid quality drop THS
Downlink rapid quality drop Value N
Quality weight of recent measure value
Level weight of recent measurement value level
The load of HO from FR to HR(V3)
The load of HO from FR to HR(V1)
The quality of HO from FR to HR
The quality of HO from HR(V1) to FR
The quality of HO from HR(V3) to FR
P value of load and quality handover
N value of load and quality handover

Penalty time for handover caused

by interference

Interference band requirement for intracell handover caused by interference


Prefer layer for traffic handover
PBGT offset of prefer layer for traffic handover
Prefer band for traffic handover
PBGT offset of prefer band for traffic handover
The threshold for starting Downlink Rapid handover
High speed threshold
Middle speed threshold
The minimum interval of direction handover
The ncell offset for downlink rapid handover
The offset of ncell in the same direction
Allow signal quality handover on TCH(High speed)
Allow signal quality handover on TCH(Middle speed)
Allow signal quality handover on TCH(Low speed)
Handover Threshole of Mean Bit Error Probability on TCH
Handover P Number of Mean Bit Error Probability on TCH
Handover N Number of Mean Bit Error Probability on TCH
Handover Threshole of CV Bit Error Probability on TCH
Handover P Number of CV Bit Error Probability on TCH
Handover N Number of CV Bit Error Probability on TCH
If support intra-handover from FR to HR due to high load
If support intra-handover from HR to FR due to bad quality
Is Dual-Frequency Traffic Handover Support
Dual-Frequency Handover Parameter N
Dual-Frequency Handover Parameter P
Dual-Frequency Handover TA Threshold
Dual-Frequency Handover RxLevel Threshold
Circuit data handover control
Back to Source Cell when PBGT Handover

Back to Source Cell when Other

Handover

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 7 of 134

HoAccess Require Rxlevel offset



HoAccess Require Rxlevel Select

Strategy when Other Handover

Dual-Frequency Traffic Handover Threshold


Support handover from HR to FR due to low load
The load of HO from HR V1 to FR

The load of HO from HR V3 to FR

HR to FR handover downlink level start threshold


FR to HR handover downlink level start threshold
Back to Source Cell when MSC Controlled Incoming Handover
Good level and bad quality handover DL Level
HoAccess Require CI
Good level and bad quality handover enable
Penalty time for inter-subcell handover failure

Handover Control ID

Full Name Handover Control ID

Abbreviation GHandoverControl

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Handover Control ID

Instance None

Value Range and Step N/A

Unit N/A

Default Value N/A

Default Value Configuration Reason None

Configuration Rule and Adjustment Suggestion None

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink power level Sample count

Full Name Uplink power level Sample count

Abbreviation hoUlLevWindow

Managed Object Handover Control

3GPP Name Hreqave

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 8 of 134

3GPP Reference 3GPP TS 45.008

In the GSM system, BSC makes handover decision according to the measurement data. To avoid the negative impact
of burst measurement values resulting from complicated radio transmission, BSC, when making handover decision,
no longer uses the original measurement data but uses a series of average values of the measurement data.
This parameter is the window size (number of sample values) used to calculate average value of uplink signal intensity.
Description The parameter is Used in TCH handover

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 4

Number of samples should be enough for ensuring


Default Value Configuration Reason the preciseness of handover decision, and for initiating handover
as early as possible when the signal is poor during communication.

If the value is set too small and samples of handover decision are too few, the handover decision is incorrect.
Configuration Rule and Adjustment Suggestion If the value is set too large, it takes a long time to make handover decisions, which is likely to result in call drops
caused by handover delays.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink level Weight

Full Name Uplink level Weight

Abbreviation hoUlLevWeight

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Speech data is unavailable for silent period during conversation. GSM specifications recommend Discontinuous
Transmission Mode (DTX) to control optimal usage of network resources during such silent periods.
In the DTX mode, the measurement data reported to BSC fall into two types. One is the average of the measurement
results of all timeslots in a measurement period in the non-DTX mode, and the other is the average of the
measurement results of some special timeslots in a measurement period in the DTX mode. BSC needs to optionally
select one type of measurement data and use the data to calculate the average value.
The first type of measurement data is the average of the measurement results of all timeslots, and it is accurate. But the
second type of measurement data is the average of the measurement results of some timeslots, and it is less accurate.
Therefore, BSC, when averaging the measurement values, uses different weights for the two types of measurement
data.
This parameter determines the weight for the first type of measurement data when averaging uplink signal strength for
Description power control. Weight for the second type of measurement data is set to 1 by default.

Instance Cell

Value Range and Step 1..3

Unit N/A

Default Value 2

In the non-DTX mode, the measurement data is


Default Value Configuration Reason
accurate, so the weight is relatively high.

Generally, it is recommended not to modify


Configuration Rule and Adjustment Suggestion
the weight.

Change Mode Offline

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 9 of 134

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink power level Sample count

Full Name Downlink power level Sample count

Abbreviation hoDlLevWindow

Managed Object Handover Control

3GPP Name Hreqave

3GPP Reference 3GPP TS 45.008

In the GSM system, BSC makes handover decision according to the measurement data. To avoid the negative impact
of burst measurement values resulting from complicated radio transmission, BSC, when making handover decision,
no longer uses the original measurement data but uses a series of average values of the measurement data.
This parameter represents the window size (i.e. the number of sample values) used to calculate the average value of
downlink signal intensity.
Description The parameter is Used in TCH handover

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 4

Number of samples should be enough for ensuring


Default Value Configuration Reason the preciseness of handover decision, and for initiating handover
as early as possible when the signal is poor during communication.

If the value is set too small and samples of handover decision are too few, the handover decision is incorrect.
Configuration Rule and Adjustment Suggestion If the value is set too large, it takes a long time to make handover decisions, which is likely to result in call drops
caused by handover delays.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink level Weight

Full Name Downlink level Weight

Abbreviation hoDlLevWeight

Managed Object Handover Control

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 10 of 134

3GPP Name N/A

3GPP Reference N/A

According to GSM Specifications, discontinuous transmission (DTX) refers to the process in which the system does
not transmit signals in the voice intermittent period during the subscriber communication process.
In the DTX mode, the measurement data reported to BSC fall into two types. One is the average of the measurement
results of all timeslots in a measurement period in the non-DTX mode, and the other is the average of the
measurement results of some special timeslots in a measurement period in the DTX mode.
BSC needs to optionally select one type of measurement data and use the data to calculate the average value.
The first type of measurement data is the average of the measurement results of all timeslots, and it is accurate. But the
second type of measurement data is the average of the measurement results of some timeslots, and it is less accurate.
Therefore, BSC, when averaging the measurement values, uses different weights for the two types of measurement
data.
This parameter determines the weight for the first type of measurement data when averaging downlink signal strength
Description for power control. Weight for the second type of measurement data is set to 1 by default.

Instance Cell

Value Range and Step 1..3

Unit N/A

Default Value 2

In the non-DTX mode, the measurement data is


Default Value Configuration Reason
accurate, so the weight is relatively high.

Generally, it is recommended not to modify


Configuration Rule and Adjustment Suggestion
the weight.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink quality Sample count

Full Name Uplink quality Sample count

Abbreviation hoUlQualWindow

Managed Object Handover Control

3GPP Name Hreqave

3GPP Reference 3GPP TS 45.008

In the GSM system, BSC makes handover decision according to the measurement data. To avoid the negative impact
of burst measurement values resulting from complicated radio transmission, BSC, when making handover decision,
no longer uses the original measurement data but uses a series of average values of the measurement data.
This parameter represents the window size (number of sample values) used to calculate average value of uplink signal
quality.
Description The parameter is Used in TCH handover

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 3

Number of samples should be enough for ensuring


Default Value Configuration Reason the preciseness of handover decision, and for initiating handover
as early as possible when the signal is poor during communication.

Configuration Rule and Adjustment Suggestion If the value is set too small and samples of handover decision are too few, the handover decision is incorrect.

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 11 of 134

If the value is set too large, it takes a long time to make handover decisions, which is likely to result in call drops
caused by handover delays.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink quality Weight

Full Name Uplink quality Weight

Abbreviation hoUlQualWeight

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

According to GSM Specifications, discontinuous transmission (DTX) refers to the process in which the system does
not transmit signals in the voice intermittent period during the subscriber communication process.
In the DTX mode, the measurement data reported to BSC fall into two types. One is the average of the measurement
results of all timeslots in a measurement period in the non-DTX mode, and the other is the average of the
measurement results of some special timeslots in a measurement period in the DTX mode.
BSC needs to optionally select one type of measurement data and use the data to calculate the average value.
The first type of measurement data is the average of the measurement results of all timeslots, and it is accurate. But the
second type of measurement data is the average of the measurement results of some timeslots, and it is less accurate.
Therefore, BSC, when averaging the measurement values, uses different weights for the two types of measurement
data.
This parameter determines the weight for the first type of measurement data when averaging uplink signal quality for
Description power control. Weight for the second type of measurement data is set to 1 by default.

Instance Cell

Value Range and Step 1..3

Unit N/A

Default Value 2

In the non-DTX mode, the measurement data is


Default Value Configuration Reason
accurate, so the weight is relatively high.

Generally, it is recommended not to modify


Configuration Rule and Adjustment Suggestion
the weight.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 12 of 134

Downlink quality Sample count

Full Name Downlink quality Sample count

Abbreviation hoDlQualWindow

Managed Object Handover Control

3GPP Name Hreqave

3GPP Reference 3GPP TS 45.008

In the GSM system, BSC makes handover decision according to the measurement data. To avoid the negative impact
of burst measurement values resulting from complicated radio transmission, BSC, when making handover decision,
no longer uses the original measurement data but uses a series of average values of the measurement data.
This parameter represents the window size (i.e. the number of sample values) used to calculate the average value of
downlink signal quality.
Description The parameter is Used in TCH handover

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 3

Number of samples should be enough for ensuring


Default Value Configuration Reason the preciseness of handover decision, and for initiating handover
as early as possible when the signal is poor during communication.

If the value is set too small and samples of handover decision are too few, the handover decision is incorrect.
Configuration Rule and Adjustment Suggestion If the value is set too large, it takes a long time to make handover decisions, which is likely to result in call drops
caused by handover delays.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink quality Weight

Full Name Downlink quality Weight

Abbreviation hoDlQualWeight

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

According to GSM Specifications, discontinuous transmission (DTX) refers to the process in which the system does
not transmit signals in the voice intermittent period during the subscriber communication process.
In the DTX mode, the measurement data reported to BSC fall into two types. One is the average of the measurement
results of all timeslots in a measurement period in the non-DTX mode, and the other is the average of the
measurement results of some special timeslots in a measurement period in the DTX mode.
BSC needs to optionally select one type of measurement data and use the data to calculate the average value.
The first type of measurement data is the average of the measurement results of all timeslots, and it is accurate. But the
second type of measurement data is the average of the measurement results of some timeslots, and it is less accurate.
Therefore, BSC, when averaging the measurement values, uses different weights for the two types of measurement
data.
This parameter determines the weight for the first type of measurement data when averaging downlink signal quality for
Description power control. Weight for the second type of measurement data is set to 1 by default.

Instance Cell

Value Range and Step 1..20

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 13 of 134

Unit N/A

Default Value 2

In the non-DTX mode, the measurement data is


Default Value Configuration Reason
accurate, so the weight is relatively high.

Generally, it is recommended not to modify


Configuration Rule and Adjustment Suggestion
the weight.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Distance

Full Name Distance

Abbreviation distanceWindow

Managed Object Handover Control

3GPP Name Hreqave

3GPP Reference 3GPP TS 45.008

In the GSM system, BSC makes handover decision according to the measurement data. To avoid the negative impact
of burst measurement values resulting from complicated radio transmission, BSC, when making handover decision,
no longer uses the original measurement data but uses a series of average values of the measurement data.
This parameter represents the window size (number of sample values) used to calculate average value of distance
(timing advance) between MS and BTS.
Description The parameter is Used in TCH handover

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 4

Number of samples should be enough for ensuring


Default Value Configuration Reason the preciseness of handover decision, and for initiating handover
as early as possible when the signal is poor during communication.

If the value is set too small and samples of handover decision are too few, the handover decision is incorrect.
Configuration Rule and Adjustment Suggestion If the value is set too large, it takes a long time to make handover decisions, which is likely to result in call drops
caused by handover delays.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 14 of 134

Parameter Modifying Detail None

Neighboring cell

Full Name Neighboring cell

Abbreviation ncellWindow

Managed Object Handover Control

3GPP Name Hreqave

3GPP Reference 3GPP TS 45.008

In the GSM system, BSC makes handover decision according to the measurement data. To avoid the negative impact
of burst measurement values resulting from complicated radio transmission, BSC, when making handover decision,
no longer uses the original measurement data but uses a series of average values of the measurement data.
This parameter represents the window size (number of sample values) used to calculate average value of signal
intensity for adjacent cells.
Description The parameter is Used in TCH handover

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 4

Number of samples should be enough for ensuring


Default Value Configuration Reason the preciseness of handover decision, and for initiating handover
as early as possible when the signal is poor during communication.

If the value is set too small and samples of handover decision are too few, the handover decision is incorrect.
Configuration Rule and Adjustment Suggestion If the value is set too large, it takes a long time to make handover decisions, which is likely to result in call drops
caused by handover delays.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Number of zero allowed in AV

Full Name Number of zero allowed in AV

Abbreviation zeroAllowed

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

According to GSM specifications, MS can report to BSS the measurement data of at most six adjacent cells with
strongest signal strength. Thus the measurement results might not be consecutive. For cells whose signal strength is
less than -110 dBm, the measurement data are not reported.
To avoid the negative impact of 0 on averaging, suppose occasional 0 is allowed and is not used in averaging, but
excessive occurrences of 0 indicate that the signals of this adjacent cell are too poor.
If the number of zeroes in used for average calculation exceeds Number of zero allowed in AV, then measurement
average equals to sum of reported values divided by Neighboring cell .
To be specific, during averaging, if the count of 0s in the sampling count exceeds ZeroAllowed, these sampling values
are hardly reliable, and the measurement average will be the sum of the reported values divided by NCellWindow. If the
count of 0s in the reported values does not exceed ZeroAllowed, these sampling values are much reliable and the
Description measurement average will be the sum of the reported values divided by (NCellWindow - the count of 0s).

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 15 of 134

Instance Cell

Value Range and Step 0..20

Unit N/A

Default Value 1

Occasional 0 is acceptable.Excessive occurrences


Default Value Configuration Reason
of 0 indicate that the signals of this adjacent cell are too poor.

If the number of 0s allowed is adjusted as too small, the adjacent cell with good signal maybe missed.
Configuration Rule and Adjustment Suggestion If the number of 0s allowed is adjusted as too large, handover to the adjacent cell with poor signal maybe initiated.
It is recommended to set the value as small as possible, in order to select the adjacent cell with good signal.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

MIN interval between inter-cell handover

Full Name MIN interval between inter-cell handover

Abbreviation hoMinInterval

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter specifies the interval value for which MS waits before the actual inter-cell handover occurs. Such a timer
is more predominant for MS at the boundary regions between two cells, where inter-cell handovers occur frequently.
This parameter helps restrict frequent inter-cell handover and guarantees call quality.
Inter-cell handover takes place when the timer exceeds the defined interval value from the last inter-cell handover of
MS. This parameter affects only the inter-cell handover, but not common intra-cell or inter-cell concentric handover.
In addition, micro-cell has its own handover policy, so this parameter is only effective for macro-cell layer and its
above layer.
Description For macro-cell, the default value can be 5; for micro-cell, the default value can only be 0.

Instance Cell

Value Range and Step 0..31

Unit s

Default Value 5

Default Value Configuration Reason experience value

Large value indicates a longer interval between two handovers, avoiding frequent handover but causing delay.
Configuration Rule and Adjustment Suggestion Small value indicates a shorter interval between two handovers and handover is initiated faster, causing frequent
handover.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 16 of 134

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Max time advance threshold between MS and BTS

Full Name Max time advance threshold between MS and BTS

Abbreviation distanceThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

According to GSM specifications, handover decisions depend upon received average value of uplink and downlink
signal strength. The decision process is as follows: For the latest N average values of TA (distance), if P of the N
values rises above relevant threshold value, then perform handover. The handover is due to MS being out of the cell
Description service range.

Instance Cell

{parent.cellType==0}[0..63]
{parent.cellType==1}[0..63]
{parent.cellType==2}[0..63]
{parent.cellType==3}[0..63]
Value Range and Step {parent.cellType==4}[0..219]

Unit N/A

{parent.cellType==0}63,
{parent.cellType==1}63,
{parent.cellType==2}63,
{parent.cellType==3}63,
Default Value {parent.cellType==4}219

Default Value Configuration Reason The TA handover is usually not used.

It is necessary to configure this parameter when the TA handover is used. In that case, this parameter is set to
Configuration Rule and Adjustment Suggestion
"Attempt a TA handover when an MS is beyond the coverage of the BS to a certain extent".

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink receive level Threshold

Full Name Uplink receive level Threshold

Abbreviation hoUlLevThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

Description According to GSM specifications, handover decisions depend upon received average value of uplink and downlink
signal strength. The decision process is as follows: For the latest N average values of uplink signal strength, if P of the
N values fall below relevant threshold value, perform handover to improve the uplink signal strength.
The HoUlLevThs parameter defines the related threhold value. The HoUlLevN parameter defines the related N value.
The HoUlLevP parameter defines the related P value. Usually the value of "HoUlLevThs" shall be less than the

http://127.0.0.1:8890/document?channelid=2&record=1&resultid=1&prese... 8/28/2017
Handover Control (GHandoverControl) Page 17 of 134

threshold for uplink power control. That is, perform power control first. If power control does not work, perform
handover.

Instance Cell

0:<-110
1:-110~-109
2:-109~-108
3:-108~-107
4:-107~-106
5:-106~-105
6:-105~-104
7:-104~-103
8:-103~-102
9:-102~-101
10:-101~-100
11:-100~-99
12:-99~-98
13:-98~-97
14:-97~-96
15:-96~-95
16:-95~-94
17:-94~-93
18:-93~-92
19:-92~-91
20:-91~-90
21:-90~-89
22:-89~-88
23:-88~-87
24:-87~-86
25:-86~-85
26:-85~-84
27:-84~-83
28:-83~-82
29:-82~-81
30:-81~-80
31:-80~-79
32:-79~-78
33:-78~-77
34:-77~-76
35:-76~-75
36:-75~-74
37:-74~-73
38:-73~-72
39:-72~-71
40:-71~-70
41:-70~-69
42:-69~-68
43:-68~-67
44:-67~-66
45:-66~-65
46:-65~-64
47:-64~-63
48:-63~-62
49:-62~-61
50:-61~-60
51:-60~-59
52:-59~-58
53:-58~-57
54:-57~-56
55:-56~-55
56:-55~-54
57:-54~-53
58:-53~-52
59:-52~-51
60:-51~-50
61:-50~-49
62:-49~-48
Value Range and Step 63:>-48

Unit dBm

Default Value 7

Usually, -95 dbm is considered as the demarcation


Default Value Configuration Reason
point between the good uplink level and poor uplink level.

Configuration Rule and Adjustment Suggestion The value the larger is, the handover is more
unlikely to occur, and vice versa the handover is easier to occur.If
the value is too large, quantity of call drops may rise. If the value

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 18 of 134

is too small, excessive handovers may occur.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Usually the value of "HoUlLevThs" should be


less than the threshold for uplink power control (increase). That
Relationship
is, perform power control first. If power control does not work, perform
handover.

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink receive level Threshold

Full Name Downlink receive level Threshold

Abbreviation hoDlLevThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

The handover decision can be made after a series of average values are obtained. The downlink receiving strength is
one of the causes that will bring about handover. The decision process is as follows: if the values of P out of N number
of recent downlink signal strength are lower than the related threshold, handover should be performed. And the cause
is that the downlink signal strength is too weak. Parameter HoDlLevThs defines the related threshold, parameter
HoDlLevN defines the related N value, and parameter HoDlLevP defines the related P value. HoDlLevThs defines
the threshold, which is 15 by default (-96 dBm to -95 dBm). The parameter value must be 3 dB greater than the
Description minimum electricity level (RxLevAccessMin).

Instance Cell

Value Range and Step 0:<-110


1:-110~-109
2:-109~-108
3:-108~-107
4:-107~-106
5:-106~-105
6:-105~-104
7:-104~-103
8:-103~-102
9:-102~-101
10:-101~-100
11:-100~-99
12:-99~-98
13:-98~-97
14:-97~-96
15:-96~-95
16:-95~-94
17:-94~-93
18:-93~-92
19:-92~-91
20:-91~-90
21:-90~-89
22:-89~-88
23:-88~-87
24:-87~-86
25:-86~-85
26:-85~-84
27:-84~-83
28:-83~-82
29:-82~-81
30:-81~-80
31:-80~-79
32:-79~-78

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 19 of 134

33:-78~-77
34:-77~-76
35:-76~-75
36:-75~-74
37:-74~-73
38:-73~-72
39:-72~-71
40:-71~-70
41:-70~-69
42:-69~-68
43:-68~-67
44:-67~-66
45:-66~-65
46:-65~-64
47:-64~-63
48:-63~-62
49:-62~-61
50:-61~-60
51:-60~-59
52:-59~-58
53:-58~-57
54:-57~-56
55:-56~-55
56:-55~-54
57:-54~-53
58:-53~-52
59:-52~-51
60:-51~-50
61:-50~-49
62:-49~-48
63:>-48

Unit dBm

Default Value 15

Usually, -95 dbm is considered as the demarcation


Default Value Configuration Reason
point between the good uplink level and poor uplink level.

The value the larger is, the handover is more


unlikely to occur, and vice versa the handover is easier to occur.If
Configuration Rule and Adjustment Suggestion
the value is too large, quantity of call drops may rise. If the value
is too small, excessive handovers may occur.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Usually the value of "HoDlLevThs" shall be less than the threshold for downlink power control (increase). That is,
Relationship
perform power control first. If power control does not work, perform handover.

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink receive quality Threshold

Full Name Uplink receive quality Threshold

Abbreviation hoUlQualThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

Description According to GSM specifications, handover decisions depend upon received average value of uplink and downlink
signal strength. The decision process is as follows: For the latest N average values of uplink signal quality, if P of the N
values rise above relevant threshold value, perform handover to improve the uplink signal quality. The HoUlQualThs
parameter defines the related threhold value.

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 20 of 134

Usually the value of "HoUlQualThs" shall be greater than the threshold for uplink power control (increase). That is,
perform power control first. If power control does not work, perform handover. The HoUlQualN parameter defines the
related N value. The HoUlQualP parameter defines the related P value.

Instance Cell

Value Range and Step 8..70

Unit N/A

Default Value 49

Generally, the quality is considered as poor


Default Value Configuration Reason
when its level is above 49.

The value the larger is, the handover is more


unlikely to occur, and vice versa the handover is easier to occur.If
Configuration Rule and Adjustment Suggestion
the value is too large, quantity of call drops may rise. If the value
is too small, excessive handovers may occur.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink receive quality Threshold

Full Name Downlink receive quality Threshold

Abbreviation hoDlQualThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

This parameter specifies a downlink receive quality threshold.


As specified in GSM specifications, a handover decision can be made after enough average values are obtained. The
downlink receive quality is one of the handover reasons. If P (HoDlQualP) of the latest N (HoDlQualN) average
downlink receive quality values are greater than this threshold (HoDlQualThs), a handover decision is made due to
poor downlink receive quality.
The downlink receive quality threshold (HoDlQualThs) must be greater than the threshold for downlink power control
(increase), which is specified by the parameter PcDlInclQualThs in the R_POC table. When the downlink receive quality
Description is poor, the BSC carries out a power control first. The handover decision is made only when the power control fails.

Instance Cell

Value Range and Step 8..70

Unit N/A

Default Value 49

Generally, the quality is considered as poor


Default Value Configuration Reason
when its level is above 49.

The value the larger is, the handover is more


unlikely to occur, and vice versa the handover is easier to occur.If
Configuration Rule and Adjustment Suggestion
the value is too large, quantity of call drops may rise. If the value
is too small, excessive handovers may occur.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 21 of 134

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink receive level of intra-ho Threshold

Full Name Uplink receive level of intra-ho Threshold

Abbreviation intraHoUlLevThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

This parameter specifies an uplink receive level threshold.


As specified in GSM specifications, a handover decision can be made after enough average values are obtained. The
uplink receive level is one of the handover reasons. If P (IntraHoUlLevP) of the latest N (IntraHoUlLevN) average
uplink receive level values are greater than this threshold (IntraHoUlLevThs), an intra-cell handover decision is made
due to serious uplink (co-frequency) interference.
The uplink receive level threshold (IntraHoUlLevThs) must be greater than the threshold for uplink power control
Description (decrease).

Instance Cell

Value Range and Step 0:<-110


1:-110~-109
2:-109~-108
3:-108~-107
4:-107~-106
5:-106~-105
6:-105~-104
7:-104~-103
8:-103~-102
9:-102~-101
10:-101~-100
11:-100~-99
12:-99~-98
13:-98~-97
14:-97~-96
15:-96~-95
16:-95~-94
17:-94~-93
18:-93~-92
19:-92~-91
20:-91~-90
21:-90~-89
22:-89~-88
23:-88~-87
24:-87~-86
25:-86~-85
26:-85~-84
27:-84~-83
28:-83~-82
29:-82~-81
30:-81~-80
31:-80~-79
32:-79~-78
33:-78~-77
34:-77~-76
35:-76~-75
36:-75~-74
37:-74~-73
38:-73~-72
39:-72~-71
40:-71~-70
41:-70~-69
42:-69~-68
43:-68~-67

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 22 of 134

44:-67~-66
45:-66~-65
46:-65~-64
47:-64~-63
48:-63~-62
49:-62~-61
50:-61~-60
51:-60~-59
52:-59~-58
53:-58~-57
54:-57~-56
55:-56~-55
56:-55~-54
57:-54~-53
58:-53~-52
59:-52~-51
60:-51~-50
61:-50~-49
62:-49~-48
63:>-48

Unit dBm

Default Value 35

Default Value Configuration Reason experience value

The period to submit an uplink measurement


report is 20 ms and the period to submit an downlink measurement report
Configuration Rule and Adjustment Suggestion
is 200 ms, so the average value of the uplink is larger than that
of the downlink.

Change Mode Offline

ZGB-02-02-001 Basic Handover


Related features ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink receive level of intra-ho Threshold

Full Name Downlink receive level of intra-ho Threshold

Abbreviation intraHoDlLevThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

This parameter specifies a downlink receive level threshold.


As specified in GSM specifications, a handover decision can be made after enough average values are obtained. The
downlink receive level is one of the handover reasons. If P (IntraHoDlLevP) of the latest N (IntraHoDlLevN) average
downlink receive level values are greater than this threshold (IntraHoDlLevThs), an intra-cell handover decision is
made due to serious downlink (co-frequency) interference.
The downlink receive level threshold (IntraHoDlLevThs) must be equal to or less than the threshold for downlink
Description power control (decrease).

Instance Cell

Value Range and Step 0:<-110


1:-110~-109
2:-109~-108
3:-108~-107
4:-107~-106
5:-106~-105

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 23 of 134

6:-105~-104
7:-104~-103
8:-103~-102
9:-102~-101
10:-101~-100
11:-100~-99
12:-99~-98
13:-98~-97
14:-97~-96
15:-96~-95
16:-95~-94
17:-94~-93
18:-93~-92
19:-92~-91
20:-91~-90
21:-90~-89
22:-89~-88
23:-88~-87
24:-87~-86
25:-86~-85
26:-85~-84
27:-84~-83
28:-83~-82
29:-82~-81
30:-81~-80
31:-80~-79
32:-79~-78
33:-78~-77
34:-77~-76
35:-76~-75
36:-75~-74
37:-74~-73
38:-73~-72
39:-72~-71
40:-71~-70
41:-70~-69
42:-69~-68
43:-68~-67
44:-67~-66
45:-66~-65
46:-65~-64
47:-64~-63
48:-63~-62
49:-62~-61
50:-61~-60
51:-60~-59
52:-59~-58
53:-58~-57
54:-57~-56
55:-56~-55
56:-55~-54
57:-54~-53
58:-53~-52
59:-52~-51
60:-51~-50
61:-50~-49
62:-49~-48
63:>-48

Unit dBm

Default Value 40

Default Value Configuration Reason experience value

The period to submit an uplink measurement


report is 20 ms and the period to submit an downlink measurement report
Configuration Rule and Adjustment Suggestion
is 200 ms, so the average value of the uplink is larger than that
of the downlink.

Change Mode Offline

ZGB-02-02-001 Basic Handover


Related features ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 24 of 134

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink receive level Value P

Full Name Uplink receive level Value P

Abbreviation hoUlLevP

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

According to GSM specifications, handover decisions depend upon received average value of uplink and downlink
signal strength. The decision process is as follows: For the latest N average values of uplink signal strength, if P of the
N values fall below relevant threshold value, perform handover to improve the uplink signal strength.
The HoUlLevThs parameter defines the related threhold value. The HoUlLevN parameter defines the related N value.
The HoUlLevP parameter defines the related P value. Usually the value of "HoUlLevThs" shall be less than the
threshold for uplink power control. That is, perform power control first. If power control does not work, perform
Description handover.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 2

It is recommended to set the default value


Default Value Configuration Reason
as this, so as to ensure the accuracy and rapidness of handover.

The larger the value is, it is more difficult


to perform handover. The smaller the value is, the easier the handover
Configuration Rule and Adjustment Suggestion
is.If the value is too large, quantity of call drops rises easily.
If the value is too small, number of unnecessary handovers may increase.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship HoUlLevP<=HoUlLevN

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink receive level Value N

Full Name Uplink receive level Value N

Abbreviation hoUlLevN

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

Description According to GSM specifications, handover decisions depend upon received average value of uplink and downlink
signal strength. The decision process is as follows: For the latest N average values of uplink signal strength, if P of the
N values fall below relevant threshold value, perform handover to improve the uplink signal strength.

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 25 of 134

The HoUlLevThs parameter defines the related threhold value. The HoUlLevN parameter defines the related N value.
The HoUlLevP parameter defines the related P value. Usually the value of "HoUlLevThs" shall be less than the
threshold for uplink power control. That is, perform power control first. If power control does not work, perform
handover.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 3

It is recommended to set the default value


Default Value Configuration Reason
as this, so as to ensure the accuracy and rapidness of handover.

The larger the value is, the higher is the


accuracy of handover decision, the lower is the realtime; The smaller
Configuration Rule and Adjustment Suggestion
the value is, the lower is the accuracy of handover decision, the
higher is the realtime.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship HoUlLevP<=HoUlLevN

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink receive level Value P

Full Name Downlink receive level Value P

Abbreviation hoDlLevP

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

This parameter indicates the value of P that is used for handover decision due to downlink receive level.
The default value can be set to 15 (-96 dBm to -95 dBm). The parameter value must be 3 dB greater than the minimum
receive level for access (RxLevAccessMin).
As specified in GSM specifications, a handover decision can be made after enough average values are obtained. The
downlink receive level is one of the handover reasons. If P (HoDlLevP) of the latest N (HoDlLevN) average downlink
receive level values are less than the corresponding threshold (HoDlLevThs), a handover decision is made due to
too low downlink signal level.
The downlink receive level threshold (HoDlLevThs) must be less than the threshold for downlink power control
(increase). When the downlink receive level is too low, the BSC carries out a power control first. The handover
Description decision is made only when the power control fails.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 2

It is recommended to set the default value


Default Value Configuration Reason
as this, so as to ensure the accuracy and rapidness of handover.

The larger the value is, it is more difficult


to perform handover. The smaller the value is, the easier the handover
Configuration Rule and Adjustment Suggestion
is.If the value is too large, quantity of call drops rises easily.
If the value is too small, number of unnecessary handovers may increase.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 26 of 134

Related Parameters N/A

Relationship HoDlLevP<=HoDlLevN

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink receive level Value N

Full Name Downlink receive level Value N

Abbreviation hoDlLevN

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

This parameter indicates the value of N that is used for handover decision due to downlink receive level.
The default value can be set to 15 (-96 dBm to -95 dBm). The parameter value must be 3 dB greater than the minimum
receive level for access (RxLevAccessMin).
As specified in GSM specifications, a handover decision can be made after enough average values are obtained. The
downlink receive level is one of the handover reasons. If P (HoDlLevP) of the latest N (HoDlLevN) average downlink
receive level values are less than the corresponding threshold (HoDlLevThs), a handover decision is made due to
too low downlink signal level.
The downlink receive level threshold (HoDlLevThs) must be less than the threshold for downlink power control
(increase). When the downlink receive level is too low, the BSC carries out a power control first. The handover
Description decision is made only when the power control fails.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 3

It is recommended to set the default value


Default Value Configuration Reason
as this, so as to ensure the accuracy and rapidness of handover.

The larger the value is, the higher is the


accuracy of handover decision, the lower is the realtime; The smaller
Configuration Rule and Adjustment Suggestion
the value is, the lower is the accuracy of handover decision, the
higher is the realtime.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship HoDlLevP<=HoDlLevN

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink receive quality Value P

Full Name Uplink receive quality Value P

Abbreviation hoUlQualP

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 27 of 134

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

According to GSM specifications, handover decisions depend upon received average value of uplink and downlink
signal strength. The decision process is as follows: For the latest N average values of uplink signal quality, if P of the N
values rise above relevant threshold value, perform handover to improve the uplink signal quality. The HoUlQualThs
parameter defines the related threhold value.
Usually the value of "HoUlQualThs" shall be greater than the threshold for uplink power control (increase). That is,
perform power control first. If power control does not work, perform handover. The HoUlQualN parameter defines the
Description related N value. The HoUlQualP parameter defines the related P value.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 2

It is recommended to set the default value


Default Value Configuration Reason
as this, so as to ensure the accuracy and rapidness of handover.

The larger the value is, it is more difficult


to perform handover. The smaller the value is, the easier the handover
Configuration Rule and Adjustment Suggestion
is.If the value is too large, quantity of call drops rises easily.
If the value is too small, number of unnecessary handovers may increase.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship HoUlQualP<=HoUlQualN

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink receive quality Value N

Full Name Uplink receive quality Value N

Abbreviation hoUlQualN

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

According to GSM specifications, handover decisions depend upon received average value of uplink and downlink
signal strength. The decision process is as follows: For the latest N average values of uplink signal quality, if P of the N
values rise above relevant threshold value, perform handover to improve the uplink signal quality. The HoUlQualThs
parameter defines the related threhold value.
Usually the value of "HoUlQualThs" shall be greater than the threshold for uplink power control (increase). That is,
perform power control first. If power control does not work, perform handover. The HoUlQualN parameter defines the
Description related N value. The HoUlQualP parameter defines the related P value.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 3

It is recommended to set the default value


Default Value Configuration Reason
as this, so as to ensure the accuracy and rapidness of handover.

Configuration Rule and Adjustment Suggestion The larger the value is, the higher is the
accuracy of handover decision, the lower is the realtime; The smaller
the value is, the lower is the accuracy of handover decision, the

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 28 of 134

higher is the realtime.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship HoUlQualP<=HoUlQualN

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink receive quality Value P

Full Name Downlink receive quality Value P

Abbreviation hoDlQualP

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

This parameter indicates the value of P that is used for handover decision due to downlink receive quality.
As specified in GSM specifications, a handover decision can be made after enough average values are obtained. The
downlink receive quality is one of the handover reasons. If P (HoDlQualP) of the latest N (HoDlQualN) average
downlink receive quality values are greater than the corresponding threshold (HoDlQualThs), a handover decision
is made due to poor downlink signal quality.
The downlink receive quality threshold (HoDlQualThs) must be greater than the threshold for downlink power control
(increase), which is specified by the parameter PcDlInclQualThs in the R_POC table. When the downlink receive quality
Description is poor, the BSC carries out a power control first. The handover decision is made only when the power control fails.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 2

It is recommended to set the default value


Default Value Configuration Reason
as this, so as to ensure the accuracy and rapidness of handover.

The larger the value is, it is more difficult


to perform handover. The smaller the value is, the easier the handover
Configuration Rule and Adjustment Suggestion
is.If the value is too large, quantity of call drops rises easily.
If the value is too small, number of unnecessary handovers may increase.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship HoDlQualP<=HoDlQualN

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink receive quality Value N

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 29 of 134

Full Name Downlink receive quality Value N

Abbreviation hoDlQualN

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

This parameter indicates the value of N that is used for handover decision due to downlink receive quality.
As specified in GSM specifications, a handover decision can be made after enough average values are obtained. The
downlink receive quality is one of the handover reasons. If P (HoDlQualP) of the latest N (HoDlQualN) average
downlink receive quality values are greater than the corresponding threshold (HoDlQualThs), a handover decision
is made due to poor downlink signal quality.
The downlink receive quality threshold (HoDlQualThs) must be greater than the threshold for downlink power control
(increase), which is specified by the parameter PcDlInclQualThs in the R_POC table. When the downlink receive quality
Description is poor, the BSC carries out a power control first. The handover decision is made only when the power control fails.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 3

It is recommended to set the default value


Default Value Configuration Reason
as this, so as to ensure the accuracy and rapidness of handover.

The larger the value is, the higher is the


accuracy of handover decision, the lower is the realtime; The smaller
Configuration Rule and Adjustment Suggestion
the value is, the lower is the accuracy of handover decision, the
higher is the realtime.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship HoDlQualP<=HoDlQualN

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink receive level of intra-ho Value P

Full Name Uplink receive level of intra-ho Value P

Abbreviation intraHoUlLevP

Managed Object Handover Control

3GPP Name N1..N8,P1..P8

3GPP Reference 3GPP TS 45.008

This parameter indicates the value of P that is used for intra-handover decision due to uplink receive level. It is used
for handover on TCH.
As specified in GSM specifications, a handover decision can be made after enough average values are obtained. The
uplink receive level is one of the handover reasons. If P (IntraHoUlLevP) of the latest N (IntraHoUlLevN) average
uplink receive level values are greater than the corresponding threshold (IntraHoUlLevThs), an intra-cell handover
decision is made due to serious uplink (co-frequency) interference.
The uplink receive level threshold (IntraHoUlLevThs) must be greater than the threshold for uplink power control
Description (decrease).

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 2

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 30 of 134

Default Value Configuration Reason It is recommended to set the default value


to 2, so as to ensure the accuracy and rapidness of handover.

If the value is too small, it is very easy to satisfy the condition of handover decision, handover is too frequent.
Configuration Rule and Adjustment Suggestion
If the value is too large, it is very difficult to satisfy the condition of handover decision.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink receive level of intra-ho Value N

Full Name Uplink receive level of intra-ho Value N

Abbreviation intraHoUlLevN

Managed Object Handover Control

3GPP Name N1..N8,P1..P8

3GPP Reference 3GPP TS 45.008

This parameter indicates the value of N that is used for intra-handover decision due to uplink receive level. It is used
for handover on TCH.
As specified in GSM specifications, a handover decision can be made after enough average values are obtained. The
uplink receive level is one of the handover reasons. If P (IntraHoUlLevP) of the latest N (IntraHoUlLevN) average
uplink receive level values are greater than the corresponding threshold (IntraHoUlLevThs), an intra-cell handover
decision is made due to serious uplink (co-frequency) interference.
The uplink receive level threshold (IntraHoUlLevThs) must be greater than the threshold for uplink power control
Description (decrease).

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 3

It is recommended to set the default value


Default Value Configuration Reason
to 3, so as to ensure the accuracy and rapidness of handover.

If the value is set too small and samples of handover decision are too few, the handover decision is incorrect.
Configuration Rule and Adjustment Suggestion If the value is set too large, it takes a long time to make handover decisions, which is likely to result in call drops
caused by handover delays.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 31 of 134

Downlink receive level of intra-ho Value P

Full Name Downlink receive level of intra-ho Value P

Abbreviation intraHoDlLevP

Managed Object Handover Control

3GPP Name N1..N8,P1..P8

3GPP Reference 3GPP TS 45.008

This parameter specifies the value of P that is used for intra-cell handover decision due to downlink receive level. It is
used for handover on TCH.
As specified in GSM specifications, a handover decision can be made after enough average values are obtained. The
downlink receive level is one of the handover reasons. If P (IntraHoDlLevP) of the latest N (IntraHoDlLevN) average
downlink receive level values are greater than the corresponding threshold (IntraHoDlLevThs), an intra-cell
handover decision is made due to serious downlink (co-frequency) interference.
The downlink receive level threshold (IntraHoDlLevThs) must be equal to or less than the threshold for downlink
Description power control (decrease).

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 2

It is recommended to set the default value


Default Value Configuration Reason
to 2, so as to ensure the accuracy and rapidness of handover.

If the value is too small, it is very easy to satisfy the condition of handover decision, handover is too frequent.
Configuration Rule and Adjustment Suggestion
If the value is too large, it is very difficult to satisfy the condition of handover decision.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink receive level of intra-ho Value N

Full Name Downlink receive level of intra-ho Value N

Abbreviation intraHoDlLevN

Managed Object Handover Control

3GPP Name N1..N8,P1..P8

3GPP Reference 3GPP TS 45.008

This parameter specifies the value of N that is used for intra-cell handover decision due to downlink receive level. It is
used for handover on TCH.
As specified in GSM specifications, a handover decision can be made after enough average values are obtained. The
downlink receive level is one of the handover reasons. If P (IntraHoDlLevP) of the latest N (IntraHoDlLevN) average
downlink receive level values are greater than the corresponding threshold (IntraHoDlLevThs), an intra-cell
handover decision is made due to serious downlink (co-frequency) interference.
The downlink receive level threshold (IntraHoDlLevThs) must be equal to or less than the threshold for downlink
Description power control (decrease).

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 3

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 32 of 134

Default Value Configuration Reason It is recommended to set the default value


to 3, so as to ensure the accuracy and rapidness of handover.

If the value is set too small and samples of handover decision are too few, the handover decision is incorrect.
Configuration Rule and Adjustment Suggestion If the value is set too large, it takes a long time to make handover decisions, which is likely to result in call drops
caused by handover delays.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Distance handover Value P

Full Name Distance handover Value P

Abbreviation distanceP

Managed Object Handover Control

3GPP Name N1..N8,P1..P8

3GPP Reference 3GPP TS 45.008

According to GSM specifications, handover decisions depend upon received average value of uplink and downlink
signal strength.
The decision process is as follows: For the latest N average values of TA (distance), if P of the N values rises above
relevant threshold value, then perform handover. The handover is due to MS being out of the cell service range.
Description Parameter "DistanceN" defines the relevant N value, and parameter "DistanceP" defines the relevant P value.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 2

It is recommended to set the default value


Default Value Configuration Reason
to 2, so as to ensure the accuracy and rapidness of handover.

If the value is too small, it is very easy to satisfy the condition of handover decision, handover is too frequent.
Configuration Rule and Adjustment Suggestion
If the value is too large, it is very difficult to satisfy the condition of handover decision.

Change Mode Offline

ZGB-02-02-001 Basic Handover


Related features ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters N/A

Relationship This parameter value should be smaller than or equal to DistanceN.

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Distance handover Value N

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 33 of 134

Full Name Distance handover Value N

Abbreviation distanceN

Managed Object Handover Control

3GPP Name N1..N8,P1..P8

3GPP Reference 3GPP TS 45.008

According to GSM specifications, handover decisions depend upon received average value of uplink and downlink
signal strength.
The decision process is as follows: For the latest N average values of TA (distance), if P of the N values rises above
relevant threshold value, then perform handover. The handover is due to MS being out of the cell service range.
Description Parameter "DistanceN" defines the relevant N value, and parameter "DistanceP" defines the relevant P value.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 3

It is recommended to set the default value


Default Value Configuration Reason
to 3, so as to ensure the accuracy and rapidness of handover.

If the value is set too small and samples of handover decision are too few, the handover decision is incorrect.
Configuration Rule and Adjustment Suggestion If the value is set too large, it takes a long time to make handover decisions, which is likely to result in call drops
caused by handover delays.

Change Mode Offline

ZGB-02-02-001 Basic Handover


Related features ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters N/A

Relationship This parameter value should be larger than or equal to DistanceP.

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

PBGT handover Value P

Full Name PBGT handover Value P

Abbreviation pbgtHoP

Managed Object Handover Control

3GPP Name N1..N8,P1..P8

3GPP Reference 3GPP TS 45.008

This parameter indicates the value P in PBGT handover. In PBGT handover, if there are P values of PBGT in N PBGT
Description satisfying the handover determination condition, the PBGT handover conditions are satisfied.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 2

Default Value Configuration Reason experience value

Usually, if the value is too small, times of


handover attempts and execution will be influenced. The larger the
Configuration Rule and Adjustment Suggestion
value is, it is more difficult to perform handover, and the higher
the call drop risk is.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 34 of 134

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

PBGT handover Value N

Full Name PBGT handover Value N

Abbreviation pbgtHoN

Managed Object Handover Control

3GPP Name N1..N8,P1..P8

3GPP Reference 3GPP TS 45.008

This parameter indicated the value N in PBGT handover. In PBGT handover, if there are P values of PBGT in N PBGT
Description satisfying the handover determination condition, the PBGT handover conditions are satisfied.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 3

Default Value Configuration Reason experience value

Usually, if the value is too small, times of


handover attempts and execution will be influenced. The larger the
Configuration Rule and Adjustment Suggestion
value is, it is more difficult to perform handover, and the higher
the call drop risk is.

Change Mode Offline

ZGB-02-02-001 Basic Handover


Related features ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow intra-Cell handover attempt due to uplink interference(High Speed)

Full Name Allow intra-Cell handover attempt due to uplink interference(High Speed)

Abbreviation hoControlIntfUl_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 35 of 134

This parameter determines whether to allow intra-cell TCH handover due to uplink interference in the case of high
speed.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason Due to the practical application of the net

it is advised to enable intra-cell handover


Configuration Rule and Adjustment Suggestion (except for the handover of the single-carrier cell, and network configured
with frequency hopping) to improve the communication quality.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow intra-Cell handover attempt due to downlink interference(High Speed)

Full Name Allow intra-Cell handover attempt due to downlink interference(High Speed)

Abbreviation hoControlIntfDl_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter determines whether to allow intra-cell TCH handover due to downlink interference in the case of high
Description speed.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason based on actual scene setting

it is advised to enable intra-cell handover


Configuration Rule and Adjustment Suggestion (except for the handover of the single-carrier cell, and network configured
with frequency hopping) to improve the communication quality.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 36 of 134

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow handover due to distance(High Speed)

Full Name Allow handover due to distance(High Speed)

Abbreviation hoControlDistance_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow handover due to distance(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Unless otherwise required, this switch should


Configuration Rule and Adjustment Suggestion
not be enabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow standard PBGT handover(High Speed)

Full Name Allow standard PBGT handover(High Speed)

Abbreviation hoControlPbgt_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow standard PBGT handover(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason based on actual scene setting

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 37 of 134

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow automatic handover due to traffic(High Speed)

Full Name Allow automatic handover due to traffic(High Speed)

Abbreviation hoControlLoad_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines whether to allow automatic TCH handover based on traffic in the case of high speed.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Due to the practical application of the net.Suggest to close when it is not used.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow intra-cell handover in super TRX channel due to downlink interference(High Speed)

Full Name Allow intra-cell handover in super TRX channel due to downlink interference(High Speed)

Abbreviation hoControlIntfUlSTrx_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow intra-cell handover in super TRX channel due to downlink interference(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 38 of 134

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow intra-cell handover in super TRX channel due to uplink interference(High Speed)

Full Name Allow intra-cell handover in super TRX channel due to uplink interference(High Speed)

Abbreviation hoControlIntfDlSTrx_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow intra-cell handover in super TRX channel due to uplink interference(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow adjacent cells handover in super TRX channel due to PBGT(High Speed)

Full Name Allow adjacent cells handover in super TRX channel due to PBGT(High Speed)

Abbreviation hoControlPbgtSTrx_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 39 of 134

Description Allow adjacent cells handover in super TRX channel due to PBGT(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow rapid handover(High Speed)

Full Name Allow rapid handover(High Speed)

Abbreviation hoControlRapidLevUl_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow rapid handover(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Uplink rapid attenuation handover is mainly


Configuration Rule and Adjustment Suggestion applied to the rapid attenuation due to fast moving, strong directionality,
and blocking.

Change Mode Offline

Related features ZGO-02-02-006 Rapid Level Drop Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 40 of 134

Allow Macro-Micro delay handover(High Speed)

Full Name Allow Macro-Micro delay handover(High Speed)

Abbreviation hoControlMacroMicro_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow Macro-Micro delay handover(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

The macro-micro handover is to share traffic of the dual-layer or multilayer network. Its main application scenario is
the dual-frequency network in urban areas.
Configuration Rule and Adjustment Suggestion
If the macro-micro handover delay switch is enabled, congestion can be eased but the coverage rate will be
influenced.

Change Mode Offline

Related features ZGO-02-02-001 Handover Between Macro- and Micro-cells

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow Micro-Micro delay handover(High Speed)

Full Name Allow Micro-Micro delay handover(High Speed)

Abbreviation hoControlMicroMicro_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow Micro-Micro delay handover(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 41 of 134

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow force transfer handover(High Speed)

Full Name Allow force transfer handover(High Speed)

Abbreviation hoControlForceMove_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow force transfer handover(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Generally, this switch is disabled.


Configuration Rule and Adjustment Suggestion In the case of 1800 M and 900 M network sharing site, it is better to handover subscribers of 900 M network to 1800 M
network.At this time, you can transfer traffic by force.

Change Mode Offline

Related features ZGO-02-02-003 Directed-Shift Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow quality handover in uplink(High Speed)

Full Name Allow quality handover in uplink(High Speed)

Abbreviation hoControlQualUl_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow quality handover in uplink(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 42 of 134

Default Value Configuration Reason based on actual scene setting

Generally, quality handover in uplink is set


Configuration Rule and Adjustment Suggestion
to be allowed.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow level handover in uplink(High Speed)

Full Name Allow level handover in uplink(High Speed)

Abbreviation hoControlLevUl_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow level handover in uplink(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason based on actual scene setting

Generally, quality handover in uplink is set


Configuration Rule and Adjustment Suggestion
to be allowed.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow quality handover in downlink(High Speed)

Full Name Allow quality handover in downlink(High Speed)

Abbreviation hoControlQualDl_H

Managed Object Handover Control

3GPP Name N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 43 of 134

3GPP Reference N/A

Description Allow quality handover in downlink(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason based on actual scene setting

Generally, quality handover in uplink is set


Configuration Rule and Adjustment Suggestion
to be allowed.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow level handover in downlink(High Speed)

Full Name Allow level handover in downlink(High Speed)

Abbreviation hoControlLevDl_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow level handover in downlink(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason based on actual scene setting

Generally, quality handover in uplink is set


Configuration Rule and Adjustment Suggestion
to be allowed.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 44 of 134

Allow downlink rapid handover(High Speed)

Full Name Allow downlink rapid handover(High Speed)

Abbreviation hoControlRapidNLevDl_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow downlink rapid handover(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason based on actual scene setting

This handover is mainly applied to the high-speed


scenario. This handover algorithm requires the areas along the railway
are covered by sites in link shape, and the adjacent cell has enough
Configuration Rule and Adjustment Suggestion
overlapped coverage areas.Handover decisions can be made faster through
configuring the adjacent cell with the direction attribute, so as
to enhance handover success rate.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow C/I limited handover(High Speed)

Full Name Allow C/I limited handover(High Speed)

Abbreviation hoControlCINCell_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow C/I limited handover(High Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Under the turnoff scenario, this function can


Configuration Rule and Adjustment Suggestion be enabled for individual cells in order to prevent the tangential
cross-coverage cell.Generally, this function should not be set.

Change Mode Offline

Related features N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 45 of 134

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow downlink quality rapid handover(High Speed)

Full Name Allow downlink quality rapid handover(High Speed)

Abbreviation hoControlRadpidQDl_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates whether rapid handover due to downlink quality is allowed. It is used for handover on TCH.
A call drop may occur due to poor downlink quality after an MS starts a call or is handed over to a cell in which serious
interference exists on some spots. A rapid handover algorithm is provided for decision-making of rescue handovers in
high-speed scenarios. This algorithm uses the raw measurement data of downlink quality, applies no window for
neighbor cells, and shares the N value used for other handover decisions.
Description The rapid handover due to downlink quality has the lowest priority than the other supported handover types.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

The default value is only enabled for the cell


Default Value Configuration Reason
of poor downlink quality, rather than common cells.

Generally, This switch is enabled only when


Configuration Rule and Adjustment Suggestion
downlink quality is poor and strong interference occurs to the cell.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow intra-Cell handover attempt due to uplink interference(Middle Speed)

Full Name Allow intra-Cell handover attempt due to uplink interference(Middle Speed)

Abbreviation hoControlIntfUl_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 46 of 134

Description This parameter determines whether to trigger the intra-cell TCH handover because of uplink interference in the case of
medium speed.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason Due to the practical application of the net

it is advised to enable intra-cell handover


Configuration Rule and Adjustment Suggestion (except for the handover of the single-carrier cell, and network configured
with frequency hopping) to improve the communication quality.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow intra-Cell handover attempt due to downlink interference(Middle Speed)

Full Name Allow intra-Cell handover attempt due to downlink interference(Middle Speed)

Abbreviation hoControlIntfDl_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter determines whether to allow the intra-cell TCH handover due to uplink interference in the case of
Description medium speed.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason based on actual scene setting

it is advised to enable intra-cell handover


Configuration Rule and Adjustment Suggestion (except for the handover of the single-carrier cell, and network configured
with frequency hopping) to improve the communication quality.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 47 of 134

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow handover due to distance(Middle Speed)

Full Name Allow handover due to distance(Middle Speed)

Abbreviation hoControlDistance_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow handover due to distance(Middle Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Unless otherwise required, this switch should


Configuration Rule and Adjustment Suggestion
not be enabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow standard PBGT handover(Middle Speed)

Full Name Allow standard PBGT handover(Middle Speed)

Abbreviation hoControlPbgt_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow standard PBGT handover(Middle Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason based on actual scene setting

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 48 of 134

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow automatic handover due to traffic(Middle Speed)

Full Name Allow automatic handover due to traffic(Middle Speed)

Abbreviation hoControlLoad_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines whether to allow automatic TCH handover based on traffic in the case of medium speed.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Due to the practical application of the net.Suggest to close when it is not used.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow intra-cell handover in super TRX channel due to downlink interference(Middle Speed)

Full Name Allow intra-cell handover in super TRX channel due to downlink interference(Middle Speed)

Abbreviation hoControlIntfUlSTrx_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow intra-cell handover in super TRX channel due to downlink interference(Middle Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 49 of 134

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow intra-cell handover in super TRX channel due to uplink interference(Middle Speed)

Full Name Allow intra-cell handover in super TRX channel due to uplink interference(Middle Speed)

Abbreviation hoControlIntfDlSTrx_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow intra-cell handover in super TRX channel due to uplink interference(Middle Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow adjacent cells handover in super TRX channel due to PBGT(Middle Speed)

Full Name Allow adjacent cells handover in super TRX channel due to PBGT(Middle Speed)

Abbreviation hoControlPbgtSTrx_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 50 of 134

Description Allow adjacent cells handover in super TRX channel due to PBGT(Middle Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow rapid handover(Middle Speed)

Full Name Allow rapid handover(Middle Speed)

Abbreviation hoControlRapidLevUl_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow rapid handover(Middle Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Uplink rapid attenuation handover is mainly


Configuration Rule and Adjustment Suggestion applied to the rapid attenuation due to fast moving, strong directionality,
and blocking.

Change Mode Offline

Related features ZGO-02-02-006 Rapid Level Drop Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 51 of 134

Allow Macro-Micro delay handover(Middle Speed)

Full Name Allow Macro-Micro delay handover(Middle Speed)

Abbreviation hoControlMacroMicro_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow Macro-Micro delay handover(Middle Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

The macro-micro handover is to share traffic of the dual-layer or multilayer network. Its main application scenario is
the dual-frequency network in urban areas.
Configuration Rule and Adjustment Suggestion
If the macro-micro handover delay switch is enabled, congestion can be eased but the coverage rate will be
influenced.

Change Mode Offline

Related features ZGO-02-02-001 Handover Between Macro- and Micro-cells

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow Micro-Micro delay handover(Middle Speed)

Full Name Allow Micro-Micro delay handover(Middle Speed)

Abbreviation hoControlMicroMicro_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow Micro-Micro delay handover(Middle Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 52 of 134

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow force transfer handover(Middle Speed)

Full Name Allow force transfer handover(Middle Speed)

Abbreviation hoControlForceMove_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow force transfer handover(Middle Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Generally, this switch is disabled.


Configuration Rule and Adjustment Suggestion In the case of 1800 M and 900 M network sharing site, it is better to handover subscribers of 900 M network to 1800 M
network.At this time, you can transfer traffic by force.

Change Mode Offline

Related features ZGO-02-02-003 Directed-Shift Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow quality handover in uplink(Middle Speed)

Full Name Allow quality handover in uplink(Middle Speed)

Abbreviation hoControlQualUl_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow quality handover in uplink(Middle Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 53 of 134

Default Value Configuration Reason based on actual scene setting

Generally, quality handover in uplink is set


Configuration Rule and Adjustment Suggestion
to be allowed.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow level handover in uplink(Middle Speed)

Full Name Allow level handover in uplink(Middle Speed)

Abbreviation hoControlLevUl_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow level handover in uplink(Middle Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason based on actual scene setting

Generally, quality handover in uplink is set


Configuration Rule and Adjustment Suggestion
to be allowed.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow quality handover in downlink(Middle Speed)

Full Name Allow quality handover in downlink(Middle Speed)

Abbreviation hoControlQualDl_M

Managed Object Handover Control

3GPP Name N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 54 of 134

3GPP Reference N/A

Description Allow quality handover in downlink(Middle Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason based on actual scene setting

Generally, quality handover in uplink is set


Configuration Rule and Adjustment Suggestion
to be allowed.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow level handover in downlink(Middle Speed)

Full Name Allow level handover in downlink(Middle Speed)

Abbreviation hoControlLevDl_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow level handover in downlink(Middle Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason based on actual scene setting

Generally, quality handover in uplink is set


Configuration Rule and Adjustment Suggestion
to be allowed.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 55 of 134

Allow downlink rapid handover(Middle Speed)

Full Name Allow downlink rapid handover(Middle Speed)

Abbreviation hoControlRapidNLevDl_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow downlink rapid handover(Middle Speed)

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason based on actual scene setting

This handover is mainly applied to the high-speed


scenario. This handover algorithm requires the areas along the railway
are covered by sites in link shape, and the adjacent cell has enough
Configuration Rule and Adjustment Suggestion
overlapped coverage areas.Handover decisions can be made faster through
configuring the adjacent cell with the direction attribute, so as
to enhance handover success rate.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow C/I limited handover(Middle Speed)

Full Name Allow C/I limited handover(Middle Speed)

Abbreviation hoControlCINCell_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates whether handover to C/I limited adjacent cell is supported in intermediate speed scenarios.
Suppose A is a serving cell. B and C are neighbor cells of A. Then B is a C/I limited neighbor cell of C. If both B and C
meet the handover conditions and C/I threshold crossing occurs, the handover is limited to the neighbor cell B.
This parameter uses the 24th bit of the HoControl field (DWORD data type).
Description This parameter is available in V6.20.21 and later versions.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Under the turnoff scenario, this function can


Configuration Rule and Adjustment Suggestion be enabled for individual cells in order to prevent the tangential
cross-coverage cell.Generally, this function should not be set.

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 56 of 134

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow downlink quality rapid handover(Middle Speed)

Full Name Allow downlink quality rapid handover(Middle Speed)

Abbreviation hoControlRadpidQDl_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates whether rapid handover due to downlink quality is allowed. It is used for handover on TCH.
A call drop may occur due to poor downlink quality after an MS starts a call or is handed over to a cell in which serious
interference exists on some spots. A rapid handover algorithm is provided for decision-making of rescue handovers in
intermediate-speed scenarios. This algorithm uses the raw measurement data of downlink quality, applies no window
for neighbor cells, and shares the N value used for other handover decisions.
Description The rapid handover due to downlink quality has the lowest priority than the other supported handover types.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

The default value is only enabled for the cell


Default Value Configuration Reason
of poor downlink quality, rather than common cells.

Generally, This switch is enabled only when


Configuration Rule and Adjustment Suggestion
downlink quality is poor and strong interference occurs to the cell.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow intra-Cell handover attempt due to uplink interference(Low Speed)

Full Name Allow intra-Cell handover attempt due to uplink interference(Low Speed)

Abbreviation hoControlIntfUl_L

Managed Object Handover Control

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 57 of 134

3GPP Name N/A

3GPP Reference N/A

Description This parameter indicates whether the intra-cell TCH handover due to uplink interference can be performed.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason Due to the practical application of the net

it is advised to enable intra-cell handover


Configuration Rule and Adjustment Suggestion (except for the handover of the single-carrier cell, and network configured
with frequency hopping) to improve the communication quality.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow intra-Cell handover attempt due to downlink interference(Low Speed)

Full Name Allow intra-Cell handover attempt due to downlink interference(Low Speed)

Abbreviation hoControlIntfDl_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines whether to allow intra-cell handover attempt due to downlink interference.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason based on actual scene setting

it is advised to enable intra-cell handover


Configuration Rule and Adjustment Suggestion (except for the handover of the single-carrier cell, and network configured
with frequency hopping) to improve the communication quality.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 58 of 134

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow handover due to distance(Low Speed)

Full Name Allow handover due to distance(Low Speed)

Abbreviation hoControlDistance_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines whether to allow standard PBGT handover.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Unless otherwise required, this switch should


Configuration Rule and Adjustment Suggestion
not be enabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow standard PBGT handover(Low Speed)

Full Name Allow standard PBGT handover(Low Speed)

Abbreviation hoControlPbgt_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines whether to allow handover due to distance.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason based on actual scene setting

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 59 of 134

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow automatic handover due to traffic(Low Speed)

Full Name Allow automatic handover due to traffic(Low Speed)

Abbreviation hoControlLoad_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines whether to allow automatic handover based on traffic.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Due to the practical application of the net.Suggest to close when it is not used.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow intra-cell handover in super TRX channel due to downlink interference(Low Speed)

Full Name Allow intra-cell handover in super TRX channel due to downlink interference(Low Speed)

Abbreviation hoControlIntfUlSTrx_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines whether to allow intra-cell handover in super TRX channel due to downlink interference.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 60 of 134

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow intra-cell handover in super TRX channel due to uplink interference(Low Speed)

Full Name Allow intra-cell handover in super TRX channel due to uplink interference(Low Speed)

Abbreviation hoControlIntfDlSTrx_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines whether to allow intra-cell handover in super TRX channel due to uplink interference.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow adjacent cells handover in super TRX channel due to PBGT(Low Speed)

Full Name Allow adjacent cells handover in super TRX channel due to PBGT(Low Speed)

Abbreviation hoControlPbgtSTrx_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 61 of 134

Description This parameter determines whether to allow adjacent cells handover in super TRX channel due to PBGT

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow dynamic adjustment of handover priority

Full Name Allow dynamic adjustment of handover priority

Abbreviation hoControlPrioChg

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter determines whether to allow dynamic adjustment of handover priority.


Description This parameter is supported from version 6.20.614b.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

For the network with relatively high handover


Configuration Rule and Adjustment Suggestion
congestion, it is recommended to enable this switch.

Change Mode Offline

Related features ZGO-02-02-002 Dynamic Handover Priority Algorithm

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 62 of 134

Allow rapid handover(Low Speed)

Full Name Allow rapid handover(Low Speed)

Abbreviation hoControlRapidLevUl_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter determines whether to allow rapid handover.


Description This parameter is supported from version 6.20.614b.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Uplink rapid attenuation handover is mainly


Configuration Rule and Adjustment Suggestion applied to the rapid attenuation due to fast moving, strong directionality,
and blocking.

Change Mode Offline

Related features ZGO-02-02-006 Rapid Level Drop Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow Macro-Micro delay handover(Low Speed)

Full Name Allow Macro-Micro delay handover(Low Speed)

Abbreviation hoControlMacroMicro_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines whether to allow Macro-Micro delay handover.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

The macro-micro handover is to share traffic of the dual-layer or multilayer network. Its main application scenario is
the dual-frequency network in urban areas.
Configuration Rule and Adjustment Suggestion
If the macro-micro handover delay switch is enabled, congestion can be eased but the coverage rate will be
influenced.

Change Mode Offline

Related features ZGO-02-02-001 Handover Between Macro- and Micro-cells

Related Parameters N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 63 of 134

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow Micro-Micro delay handover(Low Speed)

Full Name Allow Micro-Micro delay handover(Low Speed)

Abbreviation hoControlMicroMicro_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines if to allow Micro-Micro delay handover.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Configuration Rule and Adjustment Suggestion Generally, this switch is disabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow force transfer handover(Low Speed)

Full Name Allow force transfer handover(Low Speed)

Abbreviation hoControlForceMove_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines whether to allow forced transfer handover.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 64 of 134

Default Value Configuration Reason The functional Switch, default: close

Generally, this switch is disabled.


Configuration Rule and Adjustment Suggestion In the case of 1800 M and 900 M network sharing site, it is better to handover subscribers of 900 M network to 1800 M
network.At this time, you can transfer traffic by force.

Change Mode Offline

Related features ZGO-02-02-003 Directed-Shift Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow quality handover in uplink(Low Speed)

Full Name Allow quality handover in uplink(Low Speed)

Abbreviation hoControlQualUl_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter describes whether quality handover in uplink is allowed.


Description This parameter is supported from version 6.20.614b.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason based on actual scene setting

Generally, quality handover in uplink is set


Configuration Rule and Adjustment Suggestion
to be allowed.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow level handover in uplink(Low Speed)

Full Name Allow level handover in uplink(Low Speed)

Abbreviation hoControlLevUl_L

Managed Object Handover Control

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 65 of 134

3GPP Name N/A

3GPP Reference N/A

This parameter describes whether level handover in uplink is allowed.


Description This parameter is supported from version 6.20.614b.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason based on actual scene setting

Generally, quality handover in uplink is set


Configuration Rule and Adjustment Suggestion
to be allowed.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow quality handover in downlink(Low Speed)

Full Name Allow quality handover in downlink(Low Speed)

Abbreviation hoControlQualDl_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter describes whether quality handover in downlink is allowed.


Description This parameter is supported from version 6.20.614b.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason based on actual scene setting

Generally, quality handover in uplink is set


Configuration Rule and Adjustment Suggestion
to be allowed.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 66 of 134

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow level handover in downlink(Low Speed)

Full Name Allow level handover in downlink(Low Speed)

Abbreviation hoControlLevDl_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter describes whether level handover in downlink is allowed.


Description This parameter is supported from version 6.20.614b.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason based on actual scene setting

Generally, quality handover in uplink is set


Configuration Rule and Adjustment Suggestion
to be allowed.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow downlink rapid handover(Low Speed)

Full Name Allow downlink rapid handover(Low Speed)

Abbreviation hoControlRapidNLevDl_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates whether to enable SDCCH downlink rapid handover.


Description This parameter is supported from version 6.20.614b.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason based on actual scene setting

Configuration Rule and Adjustment Suggestion This handover is mainly applied to the high-speed
scenario. This handover algorithm requires the areas along the railway
are covered by sites in link shape, and the adjacent cell has enough

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 67 of 134

overlapped coverage areas.Handover decisions can be made faster through


configuring the adjacent cell with the direction attribute, so as
to enhance handover success rate.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow C/I limited handover(Low Speed)

Full Name Allow C/I limited handover(Low Speed)

Abbreviation hoControlCINCell_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates whether the function of handover for C/I limited adjacent cell is supported. Suppose A is the
service cell, B and C are adjacent cells of A, and B is the C/I limited adjacent cell of C. If B and C all satisfy the
handover condition and the C/I limited adjacent cell's handover threshold is also satisfied, then the adjacent cell C
should be filtered during the adjacent cell handover, in other words, C can not be taken as an adjacent cell for
handover.
Description This parameter is supported from version 6.20.21.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

Under the turnoff scenario, this function can


Configuration Rule and Adjustment Suggestion be enabled for individual cells in order to prevent the tangential
cross-coverage cell.Generally, this function should not be set.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow downlink quality rapid handover(Low Speed)

Full Name Allow downlink quality rapid handover(Low Speed)

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 68 of 134

Abbreviation hoControlRadpidQDl_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter indicates whether to allow downlink quality rapid handover.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

The default value is only enabled for the cell


Default Value Configuration Reason
of poor downlink quality, rather than common cells.

Generally, This switch is enabled only when


Configuration Rule and Adjustment Suggestion
downlink quality is poor and strong interference occurs to the cell.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Synchronism

Full Name Synchronism

Abbreviation hoSyncInd

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates whether synchronous handover to a cell is allowed.


If the BSC detects that the timing advance of the cell (target cell) is equal to that of the source cell, synchronous
Description handover to the cell is allowed.

Instance Cell

0: not allowed
Value Range and Step 1: allowed

Unit N/A

Default Value 1

Default Value Configuration Reason Due to the practical application of the net

The default value is used. Usually, synchronization


Configuration Rule and Adjustment Suggestion handover occurs in the common network, so the default value should
be enabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 69 of 134

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Asynchronism

Full Name Asynchronism

Abbreviation hoNSyncInd

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates whether asynchronous handover to a cell is allowed.


Description If the BSC fails to obtain the timing advance of the cell (target cell), only asynchronous handover to the cell is allowed.

Instance Cell

0: not allowed
Value Range and Step 1: allowed

Unit N/A

Default Value 1

Default Value Configuration Reason Due to the practical application of the net

The default value is used. Usually, synchronization


Configuration Rule and Adjustment Suggestion handover occurs in the common network, so the default value should
be enabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Pseudo-synchronism

Full Name Pseudo-synchronism

Abbreviation hoFSyncInd

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates whether pseudo-synchronous handover to a cell is allowed.


If an MS can calculate the timing advance of the cell (target cell) and the MS supports pseudo-synchronous handover,
Description pseudo-synchronous handover to the cell is allowed.

Instance Cell

0: not allowed
Value Range and Step 1: allowed

Unit N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 70 of 134

Default Value 0

Default Value Configuration Reason based on field pritical request

Currently, this function is not supported and


Configuration Rule and Adjustment Suggestion
is disabled.

Change Mode Offline

Related features ZGB-02-02-003 Handover Mode

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Pre-synchronism

Full Name Pre-synchronism

Abbreviation hoPSyncInd

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates whether pre-synchronous handover to a cell is allowed.


If the BSC obtains the timing advance of the cell (target cell) and considers the timing advance when sending a
Description handover command, pre-synchronous handover to the cell is allowed.

Instance Cell

0: not allowed
Value Range and Step 1: allowed

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

The default value is used, and usually it is


Configuration Rule and Adjustment Suggestion
disabled. At present, this function cannot be supported.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Prior layer selecting parameter on signal level/quality

Full Name Prior layer selecting parameter on signal level/quality

Abbreviation layerPriority

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 71 of 134

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter decides the priority to select and sequence the candidate cells for handover. Received signal level and
signal quality decides the candidate cells for handover. Three options are available:
First hand over to adjacent cells at the upper layer of the local cell, then to those at the same layer, and finally to other
adjacent cells;
First hand over to adjacent cells at the same layer of the local cell, then to those at the upper layer, and finally to other
adjacent cells;
All adjacent cells are treated in the same way.
This parameter determines to select one of above three methods.
During handover control process, this parameter has higher priority
than normal adjacent cells.
Value Range:
1 (UPPER_LAYER): adjacent cell at above layer first, same layer next,other adjacent cells finally;
2 (SAME_LAYER): adjacent cell at same layer first, above layer next, other adjacent cells finally;
3 (ALL_LAYER): all adjacent cells are same.
Description Note: In general, micro cell adopts option 1 and macro cell adopts option 2.

Instance Cell

1: UPPER_LAYER
2: SAME_LAYER
Value Range and Step 3: ALL_LAYER

Unit N/A

Default Value 2

ThIS Parameter is no longer used. The default


Default Value Configuration Reason
value is kept.

ThIS Parameter is no longer used. The default


Configuration Rule and Adjustment Suggestion
value is kept.

Change Mode Offline

Related features ZGO-02-02-002 Dynamic Handover Priority Algorithm

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Rapid handover Threshold

Full Name Rapid handover Threshold

Abbreviation rapidHoThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

During fast fading handover, some parameters shall be used. If the measured signal intensity of a call is less than rapid
handover threshold, then it triggers handover of existing cell to most probable candidate cell. "RapidHoThs" may be
Description set as 15 (that is, -96dBm ~ -95dBm) by default, the same as the level threshold of ordinary handover.

Instance Cell

Value Range and Step 0:<-110


1:-110~-109
2:-109~-108
3:-108~-107
4:-107~-106
5:-106~-105

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 72 of 134

6:-105~-104
7:-104~-103
8:-103~-102
9:-102~-101
10:-101~-100
11:-100~-99
12:-99~-98
13:-98~-97
14:-97~-96
15:-96~-95
16:-95~-94
17:-94~-93
18:-93~-92
19:-92~-91
20:-91~-90
21:-90~-89
22:-89~-88
23:-88~-87
24:-87~-86
25:-86~-85
26:-85~-84
27:-84~-83
28:-83~-82
29:-82~-81
30:-81~-80
31:-80~-79
32:-79~-78
33:-78~-77
34:-77~-76
35:-76~-75
36:-75~-74
37:-74~-73
38:-73~-72
39:-72~-71
40:-71~-70
41:-70~-69
42:-69~-68
43:-68~-67
44:-67~-66
45:-66~-65
46:-65~-64
47:-64~-63
48:-63~-62
49:-62~-61
50:-61~-60
51:-60~-59
52:-59~-58
53:-58~-57
54:-57~-56
55:-56~-55
56:-55~-54
57:-54~-53
58:-53~-52
59:-52~-51
60:-51~-50
61:-50~-49
62:-49~-48
63:>-48

Unit dBm

Default Value 10

Default Value Configuration Reason experience value

Rapid handover is characterized by fast speed,


so the handover threshold should not be too large. MS will move to
Configuration Rule and Adjustment Suggestion
the area with high cell level soon. N value cannot be too large, otherwise
the timeliness of handover judgement will be influenced.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 73 of 134

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Rapid handover Value N

Full Name Rapid handover Value N

Abbreviation rapidHoN

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

During fast fading handover, some parameters shall be used. If the measured signal intensity of a call is less than rapid
handover threshold, then it triggers handover of existing cell to most probable candidate cell.
"RapidHoThs" may be set as 15 (that is, -96dBm ~ -95dBm) by default, the same as the level threshold of ordinary
handover. RapdiHoN counter defines the minimum times for which the measured signal intensity of a call is less than
Description the threshold.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 2

Default Value Configuration Reason experience value

Rapid handover is characterized by fast speed,


so the handover threshold should not be too large. MS will move to
Configuration Rule and Adjustment Suggestion
the area with high cell level soon. N value cannot be too large, otherwise
the timeliness of handover judgement will be influenced.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Handover to same layer other band neighbour cell for PBGT permitted

Full Name Handover to same layer other band neighbour cell for PBGT permitted

Abbreviation pbgtHoLayerSame

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter describes whether it is allowed to perform PBGT handover to the same layer adjacent cell with different
Description frequency band.

Instance Cell

Value Range and Step 0..1

Unit N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 74 of 134

Default Value 1

Usually, PBGT handover is used at the same


Default Value Configuration Reason
layer.

Usually, PBGT handover is used at the same


Configuration Rule and Adjustment Suggestion
layer, so that MS can select a better cell.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Handover to neighbour cell with no Layer Relation for PBGT permitted

Full Name Handover to neighbour cell with no Layer Relation for PBGT permitted

Abbreviation pbgtHoLayerUndefine

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter describes whether it is allowed to perform PBGT handover to adjacent cell with no layer relationship.

Instance Cell

Value Range and Step 0..1

Unit N/A

Default Value 1

The layer relationship is unclear. PBGT handover


Default Value Configuration Reason
is allowed when MS does not use the layered structure.

Usually, after layers are set for the cell


Configuration Rule and Adjustment Suggestion which needs PBGT handover, set not to perform PBGT handover on the
undefined layer.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Handover to upper layer neighbour cell for PBGT permitted

Full Name Handover to upper layer neighbour cell for PBGT permitted

Abbreviation pbgtHoLayerUp

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 75 of 134

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter describes whether the PBGT handover to the upper layer adjacent cell is allowed.

Instance Cell

Value Range and Step 0..1

Unit N/A

Default Value 0

This parameter is used to make the lower layer


Default Value Configuration Reason
absorb traffic easily.

Usually, handover to the upper layer adjacent


cell is not allowed.After this function is disabled, the traffic under
Configuration Rule and Adjustment Suggestion
special scenario can be shared and congestion can be alleviated, but
the call drop rate and coverage rate may be influenced..

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Handover to under layer neighbor cell for PBGT permitted

Full Name Handover to under layer neighbor cell for PBGT permitted

Abbreviation pbgtHoLayerLow

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter describes whether the PBGT handover to the lower layer adjacent cell is allowed.

Instance Cell

Value Range and Step 0..1

Unit N/A

Default Value 0

Layered structure is not set for the common


Default Value Configuration Reason
network. The value is "No" by default.

Usually, in the layered network, handover to


Configuration Rule and Adjustment Suggestion the lower layer adjacent cell is allowed.If it is not allowed, a negative
impact is brought on the congestion rate under the special scenario.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 76 of 134

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Penalty time for handover failure

Full Name Penalty time for handover failure

Abbreviation hoFailPenalTime

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter defines the penalty time for destination cell if MS fails to handover to the destination cell or channel
allocation fails during handover. During the penalty time, this parameter is used to perform an offset on the level of this
Description cell. This parameter determines penality duration.

Instance Cell

Value Range and Step 1..255

Unit N/A

Default Value 14

The default value is in accordance with the


Default Value Configuration Reason preprocessed value. If the preprocessed value 2, the penalty time
is about 7 seconds which is enough for the change of radio environment.

The default value is on the basis of the preprocessed


Configuration Rule and Adjustment Suggestion value. It should be adjusted to a larger value if the preprocessed
value is unavailable.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Difference of dynamic priority

Full Name Difference of dynamic priority

Abbreviation dynPrioOffset

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter defines a tolerable dynamic priority difference between the destination cell and local cell during a
handover when using direction-based handover algorithm. During handover, if the first cells dynamic handover priority
is higher than that of the second cell but the second cell is in MS moving direction, then the direction-based
handover algorithm works if the difference between the two cells handover priorities is within the tolerable difference.
Description MS is handover to the second cell.

Instance Cell

Value Range and Step 1..7

Unit N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 77 of 134

Default Value 1

Default Value Configuration Reason experience value

This parameter affects the priority of the


candidate cell. The larger this parameter is, the greater the priority
Configuration Rule and Adjustment Suggestion
difference between to dynamic cells should be, so as to change the
priority of two cells.

Change Mode Offline

Related features ZGO-02-02-002 Dynamic Handover Priority Algorithm

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

PBGT difference

Full Name PBGT difference

Abbreviation pbgtOffset

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter defines a tolerable PBGT difference.During handover, if the first cells PBGT is higher than that of the
second cell but the second cell is in MS moving direction, then the direction-based handover algorithm works if the
difference between the two cells PBGTs is within the tolerable difference. MS is handover to the second cell. This
Description parameter indicates this allowable difference.

Instance Cell

Value Range and Step 0..20

Unit dB

Default Value 3

Default Value Configuration Reason experience value

This parameter affects the priority of the


candidate cell. The larger this parameter is, the greater the power
Configuration Rule and Adjustment Suggestion
budget difference between two cells should be, so as to change the
priority of two cells.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Same layer permitted on traffic HO

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 78 of 134

Full Name Same layer permitted on traffic HO

Abbreviation TrafficHoLayerCtl_0

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter determines whether a neighbor cell of the same layer can be considered as a target cell during traffic
Description handover.

Instance Cell

0: not allowed
Value Range and Step 1: allowed

Unit N/A

Default Value 1

Usually, traffic handover occurs at the same


Default Value Configuration Reason layer or the lower layer, so as to save the resources at the upper
layer.

According to the layered network configuration


Configuration Rule and Adjustment Suggestion on site, select the destination layer of traffic handover to alleviate
congestion.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710a

Parameter Modifying Detail Update

Upper layer permitted on traffic HO

Full Name Upper layer permitted on traffic HO

Abbreviation TrafficHoLayerCtl_1

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter determines whether a neighbor cell of the upper layer can be considered as a target cell during traffic
Description handover.

Instance Cell

0: not allowed
Value Range and Step 1: allowed

Unit N/A

Default Value 0

Usually, traffic handover occurs at the same


Default Value Configuration Reason layer or the lower layer, so as to save the resources at the upper
layer.

According to the layered network configuration


Configuration Rule and Adjustment Suggestion on site, select the destination layer of traffic handover to alleviate
congestion.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 79 of 134

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710a

Parameter Modifying Detail Update

Lower layer permitted on traffic HO

Full Name Lower layer permitted on traffic HO

Abbreviation TrafficHoLayerCtl_2

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter determines whether a neighbor cell of the lower layer can be considered as a target cell during traffic
Description handover.

Instance Cell

0: not allowed
Value Range and Step 1: allowed

Unit N/A

Default Value 1

Usually, traffic handover occurs at the same


Default Value Configuration Reason layer or the lower layer, so as to save the resources at the upper
layer.

According to the layered network configuration


Configuration Rule and Adjustment Suggestion on site, select the destination layer of traffic handover to alleviate
congestion.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710a

Parameter Modifying Detail Update

Undefined layer permitted on traffic HO

Full Name Undefined layer permitted on traffic HO

Abbreviation TrafficHoLayerCtl_3

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines whether a neighbor cell of the unknown layer can be considered as a target cell during
traffic handover.

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 80 of 134

Instance Cell

0: not allowed
Value Range and Step 1: allowed

Unit N/A

Default Value 0

Usually, traffic handover occurs at the same


layer or the lower layer, to save the resources at the upper
Default Value Configuration Reason layer.
The undefined layed is applied to the non-hierachical network and can be set as the target cell of traffic handover as
required.

According to the layered network configuration


Configuration Rule and Adjustment Suggestion on site, select the destination layer of traffic handover to alleviate
congestion.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710a

Parameter Modifying Detail Update

GSM900 frequency band P-GSM


permitted on traffic HO

GSM900 frequency band P-GSM


Full Name permitted on traffic HO

Abbreviation TrafficHoFreqCtl_0

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates whether to allow the basic GSM9000 frequency-band (P-GSM) (ARFCN = 1 ~ 124) adjacent
Description cell to be used as the target cell to which traffic handover is performed.

Instance Cell

0: not allowed
Value Range and Step 1: allowed

Unit N/A

Default Value 1

In most cases, the GSM900 is applied in target


Default Value Configuration Reason
cells during traffic handover.

According to the frequency band used in the


Configuration Rule and Adjustment Suggestion on-site network, configure the destination frequency band used during
traffic handover, so as to alleviate congestion.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 81 of 134

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710a

Parameter Modifying Detail Update

EXT900 frequency band E-GSM permitted on traffic HO

Full Name EXT900 frequency band E-GSM permitted on traffic HO

Abbreviation TrafficHoFreqCtl_1

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates whether to allow the basic GSM9000 frequency-band (E-GSM) (ARFCN = 0 ~ 124 975 ~
Description 1023) adjacent cell to be used as the target cell to which traffic handover is performed.

Instance Cell

0: not allowed
Value Range and Step 1: allowed

Unit N/A

Default Value 0

In few cases, the E-GSM is applied in target


Default Value Configuration Reason
cells during traffic handover.

According to the frequency band used in the


Configuration Rule and Adjustment Suggestion on-site network, configure the destination frequency band used during
traffic handover, so as to alleviate congestion.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710a

Parameter Modifying Detail Update

DCS1800 frequency band permitted on traffic HO

Full Name DCS1800 frequency band permitted on traffic HO

Abbreviation TrafficHoFreqCtl_2

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates whether to allow the DCS1800 frequency-band (DCS1800) (ARFCN = 512 ~ 885) adjacent
Description cell to be used as the target cell to which traffic handover is performed.

Instance Cell

0: not allowed
Value Range and Step 1: allowed

Unit N/A

Default Value 0

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 82 of 134

In few cases, the DCS1800 is applied in target


Default Value Configuration Reason
cells during traffic handover.

According to the frequency band used in the


Configuration Rule and Adjustment Suggestion on-site network, configure the destination frequency band used during
traffic handover, so as to alleviate congestion.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710a

Parameter Modifying Detail Update

PCS1900 frequency band permitted on traffic HO

Full Name PCS1900 frequency band permitted on traffic HO

Abbreviation TrafficHoFreqCtl_4

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates whether to allow the PCS1900 frequency-band (PCS1900) (ARFCN = 512 ~ 810) adjacent cell
Description to be used as the target cell to which traffic handover is performed.

Instance Cell

0: not allowed
Value Range and Step 1: allowed

Unit N/A

Default Value 0

In few cases, the GSM1900 is applied in target


Default Value Configuration Reason
cells during traffic handover.

According to the frequency band used in the


Configuration Rule and Adjustment Suggestion on-site network, configure the destination frequency band used during
traffic handover, so as to alleviate congestion.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710a

Parameter Modifying Detail Update

GSM850 frequency band permitted on traffic HO

Full Name GSM850 frequency band permitted on traffic HO

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 83 of 134

Abbreviation TrafficHoFreqCtl_5

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates whether to allow the GSM850 frequency-band E-GSM (ARFCN = 128~251) adjacent cell to be
Description used as the target cell to which traffic handover is performed.

Instance Cell

0: not allowed
Value Range and Step 1: allowed

Unit N/A

Default Value 0

In few cases, the GSM850 is applied in target


Default Value Configuration Reason
cells during traffic handover.

According to the frequency band used in the


Configuration Rule and Adjustment Suggestion on-site network, configure the destination frequency band used during
traffic handover, so as to alleviate congestion.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710a

Parameter Modifying Detail Update

Threshold of traffic for handover

Full Name Threshold of traffic for handover

Abbreviation trafficThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

If TCH occupation rate of a cell is greater than this parameter value (number of occupied TCH channels / number of
total TCH channels, not including blocked idle channels), then it indicates the cell is too busy, and traffic handover is
Description triggered for the cell.

Instance Cell

Value Range and Step 0..100

Unit %

Default Value 80

It is proper to initiate congestion control


Default Value Configuration Reason
when the cell load reaches 80% and a few channels are available and.

For the cell with fewer channels, channel congestion


Configuration Rule and Adjustment Suggestion occurs easily caused by the burst services, so this parameter can
be set as relatively small.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 84 of 134

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Traffic handover threshold

Full Name Traffic handover threshold

Abbreviation trafficLevThs

Managed Object Handover Control

3GPP Name None

3GPP Reference N/A

This parameter is used for traffic handover. For the original handover condition that adjacent cells level must be
higher than that of this cell, modify it so that adjacent cells level must be higher than this threshold.In this way, traffic
handover can be improved greatly. This threshold must be less than the PBGT threshold in reverse direction.
Description Otherwise, it may result in toggle handover.

Instance Cell

Value Range and Step 0..48

Unit dB

Default Value 24

Default Value Configuration Reason Traffic is traffic switching to consider the balance of the target cell level can not be less than the serving cell

This parameter is valid after automatic handover based on traffic (HoControl6) is allowed.Note that the threshold of
PBGT handover in the reverse direction of the destination cell needs to be raised for compensation.
Configuration Rule and Adjustment Suggestion Under the dense traffic scenario, the smaller this parameter is, the stronger the capability of absorbing traffic of the
destination Nclayer cell or frequency band cell is, the easier the traffic can be handed out (the traffic threshold shall
be reached), which helps alleviate the TCH channel congestion of the cell.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Level offset during penalty

Full Name Level offset during penalty

Abbreviation penaltyLevOffset

Managed Object Handover Control

3GPP Name None

3GPP Reference N/A

Description This parameter is used to perform an offset on the downlink level of this cell in the penalty period.

Instance Cell

Value Range and Step 0..63

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 85 of 134

Unit dB

Default Value 15

Default Value Configuration Reason The value of field experience

The system allows three times handover failure


to a certain destination cell. When the second or third handover decision
is made, an offset is manually performed on the level of the destination
cell to which handover fails for the first time. If the destination
Configuration Rule and Adjustment Suggestion
cell still takes the first priority compared with other adjacent cells
after its level is reduced manually, go on initiating handover to
it. After the attempt fails for three times, shield it in the penalty
period.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink interference quality offset

Full Name Uplink interference quality offset

Abbreviation qOffSetUl

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates that the relationship between the level and quality determines whether channels are
interfered during the inter-cell handover. When IntraHoUlLevP out of IntraHoUlLevN measurements satisfy rxqual-
ulFQSS (RXLEV_UL+SOffSetUl), the handover condition is satisfied. Where, rxqual-ul is the uplink quality,
QOffSetUL is the uplink quality offset, AvRxlevUL(n) is the uplink level, SOffSetUL is the uplink level offset, and FQSS
is the current quality offset determined by the level and the corresponding uplink quality offset (SOffSetUl). Following
is the algorithm:
255 AvRxlevUL(n) < SOffSetUL + 20
InterFQSS= | QOffSetUl + 2 SOffSetUL + 20 AvRxlevUL(n) < SOffSetUL + 30
| QOffSetUl + 3 SOffSetUL + 30 AvRxlevUL(n) < SOffSetUL + 40
QOffSetUl + 4 SOffSetUL + 40 AvRxlevUL(n)
After the occurrence of channel interference is ensured, services should inform the database about the current channel
Description occupation rate when applying to the database for appropriate channels.

Instance Cell

Value Range and Step 0..20

Unit N/A

Default Value 10

Setting of the default value is in accordance


Default Value Configuration Reason
with the common uplink interference environment.

The larger the value is, the higher the quality


tolerability under the corresponding level is, and it is more difficult
Configuration Rule and Adjustment Suggestion
to initiate quality handover which should be adjusted in accordance
with the actual network situation.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 86 of 134

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Uplink interference level offset

Full Name Uplink interference level offset

Abbreviation sOffSetUl

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates that the relationship between the level and quality determines whether channels are
interfered during the inter-cell handover. When IntraHoUlLevP out of IntraHoUlLevN measurements satisfy rxqual-
ulFQSS (RXLEV_UL+SOffSetUl), the handover condition is satisfied. Where, rxqual-ul is the uplink quality,
QOffSetUL is the uplink quality offset, AvRxlevUL(n) is the uplink level, SOffSetUL is the uplink level offset, and FQSS
is the current quality offset determined by the level and the corresponding uplink quality offset (SOffSetUl). Following
is the algorithm:
255 AvRxlevUL(n) < SOffSetUL + 20
InterFQSS= | QOffSetUl + 2 SOffSetUL + 20 AvRxlevUL(n) < SOffSetUL + 30
| QOffSetUl + 3 SOffSetUL + 30 AvRxlevUL(n) < SOffSetUL + 40
QOffSetUl + 4 SOffSetUL + 40 AvRxlevUL(n)
After the occurrence of channel interference is ensured, services should inform the database about the current channel
Description occupation rate when applying to the database for appropriate channels.

Instance Cell

Value Range and Step 0..20

Unit N/A

Default Value 15

Setting of the default value is in accordance


Default Value Configuration Reason
with the common uplink interference environment.

The larger the value is, the higher the requirement


on quality handover is, and it is more difficult to initiate quality
Configuration Rule and Adjustment Suggestion
handover which should be adjusted in accordance with the actual network
situation.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink interference quality offset

Full Name Downlink interference quality offset

Abbreviation qOffSetDl

Managed Object Handover Control

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 87 of 134

3GPP Name N/A

3GPP Reference N/A

This parameter indicates that the relationship between the level and quality determines whether channels are interfered
during the inter-cell handover. When IntraHoUlLevP out of IntraHoDlLevN measurements satisfy rxqual-dlFQSS
(RXLEV_UL,SOffSetUl,QOffSetUL), the handover condition is satisfied. Where, rxqual-dl is the downlink quality,
QOffSetDL is the downlink quality offset, RXLEV_DL is the downlink level, SOffSetDL is the downlink level offset, and
FQSS is the current quality offset determined by the level and the corresponding downlink quality offset (SOffSetDl).
Following is the algorithm:
255 AvRxlevDL(n) < SOffSetDL + 20
InterFQSS= | QOffSetDl + 2 SOffSetDL + 20 AvRxlevDL(n) < SOffSetDL + 30
| QOffSetDl + 3 SOffSetDL + 30 AvRxlevDL(n) < SOffSetDL + 40
QOffSetDl + 4 SOffSetDL + 40 AvRxlevDL(n)
After the occurrence of channel interference is ensured, services should inform the database about the current channel
Description occupation rate when applying to the database for appropriate channels.

Instance Cell

Value Range and Step 0..20

Unit N/A

Default Value 10

Setting of the default value is in accordance


Default Value Configuration Reason
with the common downlink interference environment.

The larger the value is, the higher the quality


Configuration Rule and Adjustment tolerability under the corresponding level is, and it is more difficult
Suggestion to initiate quality handover which should be adjusted in accordance
with the actual network situation.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink interference level offset

Full Name Downlink interference level offset

Abbreviation sOffSetDl

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates that the relationship between the level and quality determines whether channels are interfered
during the inter-cell handover. When IntraHoUlLevP out of IntraHoDlLevN measurements satisfy rxqual-dlFQSS
(RXLEV_UL,SOffSetUl,QOffSetUL), the handover condition is satisfied. Where, rxqual-dl is the downlink quality,
QOffSetDL is the downlink quality offset, RXLEV_DL is the downlink level, SOffSetDL is the downlink level offset, and
FQSS is the current quality offset determined by the level and the corresponding downlink quality offset (SOffSetDl).
Following is the algorithm:
255 AvRxlevDL(n) < SOffSetDL + 20
InterFQSS= | QOffSetDl + 2 SOffSetDL + 20 AvRxlevDL(n) < SOffSetDL + 30
| QOffSetDl + 3 SOffSetDL + 30 AvRxlevDL(n) < SOffSetDL + 40
QOffSetDl + 4 SOffSetDL + 40 AvRxlevDL(n)
After the occurrence of channel interference is ensured, services should inform the database about the current channel
Description occupation rate when applying to the database for appropriate channels.

Instance Cell

Value Range and Step 0..20

Unit dB

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 88 of 134

Default Value 10

Setting of the default value is in accordance


Default Value Configuration Reason
with the common downlink interference environment.

The larger the value is, the higher the requirement


Configuration Rule and Adjustment on quality handover is, and it is more difficult to initiate quality
Suggestion handover which should be adjusted in accordance with the actual network
situation.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Invalid intra-handover time

Full Name Invalid intra-handover time

Abbreviation tMaxIHo

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

If MS performs handover continuously in the cell, it indicates great interference in this position and no appropriate
channel is available.
In such a case, MS shall be forbidden to perform handover within a certain time. The judgment method is as follows: If
handover occurs within the invalid intra-handover time, then the previous handover is considered to have no influence
on interference, the counter HoCount increases by 1 and restart TMaxIHo. If handover occurs after the invalid intra-
handover time, the previous handover is considered valid and clear the counter to 0.
If the counter value reaches the value of MAX count of invalid intra-handover parameter, then it indicates not to attempt
Description handover within a certain period. Perform penalty in intra-cell penalty mode.

Instance Cell

Value Range and Step 0..255

Unit N/A

Default Value 16

Usually, if the handover occurs continuously


Default Value Configuration Reason within 16 measurement reports (or preprocessing reports), it is considered
as too frequent.

If the time is adjusted as too short, the invalid handover is easily to be judged as valid handover.
Configuration Rule and Adjustment Suggestion
If the time is adjusted as too long, the valid handover is easily to be judged as invalid handover.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 89 of 134

Parameter Modifying Detail None

MAX count of invalid intra-handover

Full Name MAX count of invalid intra-handover

Abbreviation maxIHo

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

If MS performs handover continuously in the cell, it indicates great interference in this position and no appropriate
channel is available.
In such a case, MS shall be forbidden to perform handover within a certain time. The judgment method is as follows: If
handover occurs within the invalid intra-handover time, then the previous handover is considered to have no influence
on interference, the counter HoCount increases by 1 and restart TMaxIHo. If handover occurs after the invalid intra-
handover time, the previous handover is considered valid and clear the counter to 0.
If the counter value reaches the value of MAX count of invalid intra-handover parameter, then it indicates not to attempt
Description handover within a certain period. Perform penalty in intra-cell penalty mode.

Instance Cell

Value Range and Step 0..10

Unit N/A

Default Value 3

The default value is used to make a correct


Default Value Configuration Reason
decision on invalid handover.

If the value is too small, the handover is easily to be judged as invalid and MS is performed on penalty, which is likely to
cause call drop.
Configuration Rule and Adjustment Suggestion
If the value is too large, the handover is easily to be judged as invalid interference handover and the number of invalid
handover increases.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

MAX path loss threshold on force handover

Full Name MAX path loss threshold on force handover

Abbreviation maxLossThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Forcible handover only aims at a speccified cell. It should satisfy the following requirements:
1. The tolerable level difference (MaxLevDiff) should be lower than the PBGT handover threshold in the reverse
direction, to avoid ping-pong handover.
2. The resoureces of the target cell should be lower than the reserved resource threshold (HoForceResThs), to
prevent the target cell from congestion.
3. The path loss (L) of the MS should be lower than this parameter's threshold, and the time advance (TA) of the MS
should be less than the maximum time advance (MaxTAThs) of the forcible handover. This algorithm applies to a dual-
band network, and the 900 M/1800 M cell sharing the same site.
Where, when MaxTAThs is set to 63, the forcible handover is only determined by the path loss of the MS. When
MaxLossThs is set to 150, the forcible handover is only determined by the time advance of the MS.

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 90 of 134

The path loss (L) =BS_TXPWR - AV_RXLEV_DL


Where, BS_TXPWR is the transmission power of the carrier where the occupied timeslot locates, and depends on the
carrier's maximum transmission power, static attenuation power, and power control. AV_RXLEV_DL is the downlink
receiving level.
4. HoForceP (value P for determining forcible handover) out of HoForceN (value N for determining forcible handover)
measurement reports should satisfy the requirements for the forcible handover.

Instance Cell

Value Range and Step 0..150

Unit N/A

Default Value 110

Default Value Configuration Reason experience value

Forced handover shall meet the following requirements:


Level of the destination cell must be higher than that of the local
cell by MaxLevDiff; available resource of the destination cell must
be higher than the handover reserved resource threshold HoForceResThs;
Configuration Rule and Adjustment Suggestion
the path loss L must be less than MaxLossThs and the TA must be less
than MaxTAThs. The higher the path loss is, the poorer the signal
intensity of the destination cell is, thereby the max path loss threshold
cannot be too large.

Change Mode Offline

Related features ZGO-02-02-003 Directed-Shift Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

MAX time advance threshold on force handover

Full Name MAX time advance threshold on force handover

Abbreviation maxTaThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Forcible handover only aims at a speccified cell. It should satisfy the following requirements:
1. The tolerable level difference (MaxLevDiff) should be lower than the PBGT handover threshold in the reverse
direction, to avoid ping-pong handover.
2. The resoureces of the target cell should be lower than the reserved resource threshold (HoForceResThs), to
prevent the target cell from congestion.
3. The path loss (L) of the MS should be lower than this parameter's threshold, and the time advance (TA) of the MS
should be less than the maximum time advance (MaxTAThs) of the forcible handover. This algorithm applies to a dual-
band network, and the 900 M/1800 M cell sharing the same site.
Where, when MaxTAThs is set to 63, the forcible handover is only determined by the path loss of the MS. When
MaxLossThs is set to 150, the forcible handover is only determined by the time advance of the MS.
The path loss (L) =BS_TXPWR - AV_RXLEV_DL
Where, BS_TXPWR is the transmission power of the carrier where the occupied timeslot locates, and depends on the
carrier's maximum transmission power, static attenuation power, and power control. AV_RXLEV_DL is the downlink
receiving level.
4. HoForceP (value P for determining forcible handover) out of HoForceN (value N for determining forcible handover)
Description measurement reports should satisfy the requirements for the forcible handover.

Instance Cell

Value Range and Step 0..63

Unit N/A

Default Value 5

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 91 of 134

Default Value Configuration Reason experience value

Forced handover shall meet the following requirements:


Level of the destination cell must be higher than that of the local
cell by MaxLevDiff; available resource of the destination cell must
Configuration Rule and Adjustment Suggestion be higher than the handover reserved resource threshold HoForceResThs;
the path loss L must be less than MaxLossThs and the TA must be less
than MaxTAThs. TA value cnnot be too large. The larger the TA value
is, the poorer the cell signal intensity is.

Change Mode Offline

Related features ZGO-02-02-003 Directed-Shift Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

N value of force handover

Full Name N value of force handover

Abbreviation hoForceN

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Forcible handover only aims at a speccified cell. It should satisfy the following requirements:
1. The tolerable level difference (MaxLevDiff) should be lower than the PBGT handover threshold in the reverse
direction, to avoid ping-pong handover.
2. The resoureces of the target cell should be lower than the reserved resource threshold (HoForceResThs), to
prevent the target cell from congestion.
3. The path loss (L) of the MS should be lower than this parameter's threshold, and the time advance (TA) of the MS
should be less than the maximum time advance (MaxTAThs) of the forcible handover. This algorithm applies to a dual-
band network, and the 900 M/1800 M cell sharing the same site.
Where, when MaxTAThs is set to 63, the forcible handover is only determined by the path loss of the MS. When
MaxLossThs is set to 150, the forcible handover is only determined by the time advance of the MS.
The path loss (L) =BS_TXPWR - AV_RXLEV_DL
Where, BS_TXPWR is the transmission power of the carrier where the occupied timeslot locates, and depends on the
carrier's maximum transmission power, static attenuation power, and power control. AV_RXLEV_DL is the downlink
receiving level.
4. HoForceP (value P for determining forcible handover) out of HoForceN (value N for determining forcible handover)
Description measurement reports should satisfy the requirements for the forcible handover.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 4

Default Value Configuration Reason experience value

NWhen P times in the N times decision succeed,


Configuration Rule and Adjustment Suggestion it is allowed to initiate handover. The smaller the N value and P
value are, it is easier to initiate handover.

Change Mode Offline

Related features ZGO-02-02-003 Directed-Shift Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 92 of 134

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

P value of force handover

Full Name P value of force handover

Abbreviation hoForceP

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Forcible handover only aims at a speccified cell. It should satisfy the following requirements:
1. The tolerable level difference (MaxLevDiff) should be lower than the PBGT handover threshold in the reverse
direction, to avoid ping-pong handover.
2. The resoureces of the target cell should be lower than the reserved resource threshold (HoForceResThs), to
prevent the target cell from congestion.
3. The path loss (L) of the MS should be lower than this parameter's threshold, and the time advance (TA) of the MS
should be less than the maximum time advance (MaxTAThs) of the forcible handover. This algorithm applies to a dual-
band network, and the 900 M/1800 M cell sharing the same site.
Where, when MaxTAThs is set to 63, the forcible handover is only determined by the path loss of the MS. When
MaxLossThs is set to 150, the forcible handover is only determined by the time advance of the MS.
The path loss (L) =BS_TXPWR - AV_RXLEV_DL
Where, BS_TXPWR is the transmission power of the carrier where the occupied timeslot locates, and depends on the
carrier's maximum transmission power, static attenuation power, and power control. AV_RXLEV_DL is the downlink
receiving level.
4. HoForceP (value P for determining forcible handover) out of HoForceN (value N for determining forcible handover)
Description measurement reports should satisfy the requirements for the forcible handover.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 3

Default Value Configuration Reason experience value

NWhen P times in the N times decision succeed,


Configuration Rule and Adjustment Suggestion it is allowed to initiate handover. The smaller the N value and P
value are, it is easier to initiate handover.

Change Mode Offline

Related features ZGO-02-02-003 Directed-Shift Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Level offset for PBGT to up layer

Full Name Level offset for PBGT to up layer

Abbreviation pbgtHoUlLevOffset

Managed Object Handover Control

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 93 of 134

3GPP Name None

3GPP Reference N/A

To more effectively control traffic distribution in the cell at different layers, while doing PBGT decision, add PBGT
decision offset level in the cell at upper layer within certain duration which is dependent upon the lag time for
Description handover between different layers.

Instance Cell

Value Range and Step 0..48

Unit N/A

Default Value 24

Default Value Configuration Reason The default is not offset

The value 0-48 represents -24db~+25db. Its function is same as PBGT Margin. That is, add an inter-layer hysteresis
value based on the PBGT Margin, to attenuate or accelerate inter-layer PBGT handover.
Generally, it is better to handover to the lower layer and maintain intra-layer handover at the lower layer. The PBGT
Configuration Rule and Adjustment Suggestion
handover to the upper layer is triggered only when the upper-layer signal is always strong.
If the value is large, it assists in traffic balance and congestion reduction, reduces the possibility of PBGT handover
to the upper layer, and affects the coverage rate.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Level offset for PBGT to low layer

Full Name Level offset for PBGT to low layer

Abbreviation pbgtHoDlLevOffset

Managed Object Handover Control

3GPP Name None

3GPP Reference N/A

To more effectively control traffic distribution in the cell at different layers, while doing PBGT decision, add PBGT
decision offset level in the cell at lower layer within certain duration which is dependent upon the lag time for
Description handover between different layers.

Instance Cell

Value Range and Step 0..48

Unit N/A

Default Value 24

Default Value Configuration Reason The default is not offset

The value 0-48 represents -24db~+25db. It sfunction is the same as PBGT Margin. That is, add a inter-layer
hysteresis value based on the PBGT Margin, to attenuate or accelerate inter-layer PBGT handover.
Generally, it is better to handover to the lower layer and maintain intra-layer handover at the lower layer. The PBGT
Configuration Rule and Adjustment Suggestion
handover to the upper layer is triggered only when the upper-layer signal is always strong.
If the value is large, it assists in traffic balance and congestion reduction, reduces the possibility of PBGT handover
to the upper layer, and affects the coverage rate.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 94 of 134

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Lag time for PBGT between different layers

Full Name Lag time for PBGT between different layers

Abbreviation pbgtHoLayerHyst

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

To more effectively control traffic distribution in the cell at different layers, while doing PBGT decision, add PBGT
decision offset level in the cell at different layers within certain duration, which is lag time for PBGT between different
Description layers.

Instance Cell

Value Range and Step 0..300

Unit s

Default Value 50

Default Value Configuration Reason experience value

The value will be modified to the default value


Configuration Rule and Adjustment Suggestion (50 s) if it is 0.If the lag time is not timed out, it is necessary
to add offset to the PBGT cross-layer handover.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

The threshold for starting PBGT handover

Full Name The threshold for starting PBGT handover

Abbreviation pbgtHoStartThs

Managed Object Handover Control

3GPP Name None

3GPP Reference N/A

When the current cell's downlink level is less than the start level threshold for PBGT handover, the PBGT handover
Description decision is performed.

Instance Cell

Value Range and Step 0..63

Unit N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 95 of 134

Default Value 35

Default Value Configuration Reason The value of field experience

If the value is large, it is easy to initiate PBGT handover. If the value is small, it is difficult to initiate PBGT handover.
The value should be large when it is necessary to share traffic. Otherwise, it is difficult to share traffic and the
congestion rate is influenced.
Configuration Rule and Adjustment Suggestion
When it is unnecessary to share traffic, the value can be set to a relatively small value, which reduces the number of
unnecessary handovers but affects the coverage rate.
It is recommended to set the value of the 900 M cell to the largest in the 900 M and 1800 M dual-frequency network.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

The priority of the handover from Macro cell to Micro cell

Full Name The priority of the handover from Macro cell to Micro cell

Abbreviation macroMicroHoPrio

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter describes whether the macro-micro handover decision has higher priority than the PBGT handover
Description decision.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason based on actual scene setting

Generally, the macro-micro handover takes priority


Configuration Rule and Adjustment Suggestion
if it is enabled.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Handover from macro to micro

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 96 of 134

Full Name Handover from macro to micro

Abbreviation macroMicroStartThs

Managed Object Handover Control

3GPP Name None

3GPP Reference N/A

When the current cell's downlink level is less than or equal to the start level threshold for macro-micro handover, the
Description macro-micro handover decision is performed.

Instance Cell

Value Range and Step 0..63

Unit N/A

Default Value 63

Default Value Configuration Reason The value of field experience

Initially, it is recommended to set this parameter


as the largest, so that the 1800 M cell can absorb more traffic. The
larger this parameter is, it is more likely for the macro-micro handover
Configuration Rule and Adjustment Suggestion to occur, and it is easier for traffic to be transferred to the 1800
cell. Adjustment of this parameter depends on the current condition
and subsequent plan of traffic distribution of the 900 cell and 1800
cell.

Change Mode Offline

Related features N/A

Related Parameters N/A

This parameter is valid unless the macro-micro


Relationship
switch hocontrol_13is enabled.

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Hysteresis timer when traffic handover

Full Name Hysteresis timer when traffic handover

Abbreviation trafficHysteresisTm

Managed Object Handover Control

3GPP Name None

3GPP Reference N/A

When there are many traffic handovers initiated in the current cell, the interval between two traffic handovers must be
Description larger than the hysteresis time specified by this parameter.

Instance Cell

Value Range and Step 0..255

Unit s

Default Value 7

Default Value Configuration Reason NULL

This parameter is invalid in this version and


Configuration Rule and Adjustment Suggestion
the default is reserved.

Change Mode Offline

Related features N/A

Related Parameters N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 97 of 134

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink rapid handover offset of high speed

Full Name Downlink rapid handover offset of high speed

Abbreviation dLRapidHoOffsetH

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

After getting a series of measurement reports, you can do the decisions for SDCCH downlink rapid handover.
The downlink rapid is the reason to cause handover. The decision process is as follows: do the handover if the latest
downlink level values (without average processing) is higher than the sum of relevant threshold values and offset
values. The handover reason is downlink rapid handover. DLRapidHoOffset_0 defines the offset threshold value for
downlink rapid handover if the train speed is higher than 250km/hr.
Description This parameter is supported from version 6.20.614b.

Instance Cell

Value Range and Step 0..63

Unit N/A

Default Value 0

Default Value Configuration Reason experience value

For the threshold under high speed scenario,


rapid handover should be performed, thereby it is better to set the
Configuration Rule and Adjustment Suggestion
offset value to a relatively small value to assist in making handover
decisions.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink rapid handover offset of middle speed

Full Name Downlink rapid handover offset of middle speed

Abbreviation dLRapidHoOffsetM

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Downlink rapid handover decisions depend upon a series measurement reports received.

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 98 of 134

Downlink rapid is one of the causes for handover. The decision process is as follows: If the latest successive N
downlink level values (without average processing) are larger than the sum of relating threshold and the offset,
perform handover with the cause of downlink rapid handover.This parameter DLRapidHoOffset_1 defines the offset
threshold value for downlink rapid handover if the train speed is between 150km/hr and 250km/hr.
Since the version V6.20.614b, this parameter is supported.

Instance Cell

Value Range and Step 0..63

Unit N/A

Default Value 2

Setting of the default value is in accordance


Default Value Configuration Reason
with the radio environment that mostly the speed is 150~250km/h under the high-speed scenario.

The value is applicable to the coverage area under such high-speed scenarios as express ways, and high-speed
Configuration Rule and Adjustment Suggestion railways on which the train speed is l150~251km/h.
Higher speed requires a smaller offset value to realize a faster handover.

Change Mode Offline

Related features ZGO-02-02-018 Handover Based on Downlink Level Fast Fading

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink rapid handover offset of low speed

Full Name Downlink rapid handover offset of low speed

Abbreviation dLRapidHoOffsetL

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

After getting a series of measurement reports, you can do the decisions for downlink rapid handover.
The downlink rapid is the reason to cause handover. The decision process is as follows: do the handover if the latest
downlink level values (without average processing) is higher than the sum of relevant threshold values and offset
values. The handover reason is downlink rapid handover. DLRapidHoOffset_2 defines the offset threshold value for
Description downlink rapid handover if the train speed is lower than 150km/hr.

Instance Cell

Value Range and Step 0..63

Unit N/A

Default Value 5

Setting of the default value is in accordance


Default Value Configuration Reason with the radio environment that mostly the speed is lower than 150
km/h under the high-speed scenario.

The value is applicable to the coverage area under such high-speed scenarios as expressways, and high-speed
Configuration Rule and Adjustment Suggestion railways on which the train speed is lower than 150 km/h.
Higher speed requires a smaller offset value to realize a faster handover.

Change Mode Offline

Related features ZGO-02-02-018 Handover Based on Downlink Level Fast Fading

Related Parameters N/A

This parameter is valid till the downlink rapid


Relationship
handover is supported.

Related Interfaces N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 99 of 134

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Handover back penalty

Full Name Handover back penalty

Abbreviation hoBackPenalty

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This paramter describes the time penalty of handover back to the original cell. That is, after the handover from cell A to
Description cell B, the handover cannot be performed back to cell A within this period.

Instance Cell

Value Range and Step 0..60

Unit s

Default Value 5

Setting of the default value needs to avoid


Default Value Configuration Reason the increase of handover frequency resulting from toggle handover,
and to avoid call drops as much as possible.

If the value is too small, it is easy to perform backward handover to the original cell, toggle handover occurs.
Configuration Rule and Adjustment Suggestion
If the value is too large, it is not easy to perform backward handover to the original cell.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

MIN interval between inter-cell emergency handover

Full Name MIN interval between inter-cell emergency handover

Abbreviation HoMinIntervalEmerg

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter specifies the interval value for which MS waits before the actual inter-cell handover occurs. Such a timer
is more predominant for MS at the boundary regions between two cells, where inter-cell handovers occur frequently.
This parameter helps restrict frequent inter-cell handover and guarantees call quality.
Inter-cell handover takes place when the timer exceeds the defined interval value from the last inter-cell handover of
MS. This parameter affects only the emergent inter-cell handover, but not common intra-cell or inter-cell concentric
Description handover.

Instance Cell

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 100 of 134

Value Range and Step 0..31

Unit s

Default Value 0

If ther emergency handover is not performed,


Default Value Configuration Reason call drop occurs easily, thereby handover is initiated only if the
requirement is satisfied by default.

Frequent handover can be avoided by adjusting


Configuration Rule and Adjustment Suggestion this parameter.If the value is adjusted as too large, call drop occurs
due to handover failure.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Handover back penalty after emergency handover

Full Name Handover back penalty after emergency handover

Abbreviation HoBackPenaltyEmerg

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter describes the time limit for handover back to the original cell. In other words, after emergent handover is
Description performed from cell A to cell B, it is not allowed to perform handover from cell B back to cell A within the time limit.

Instance Cell

Value Range and Step 0..60

Unit s

Default Value 15

Setting of the default value needs to avoid


Default Value Configuration Reason the increase of handover frequency resulting from toggle handover,
and to avoid call drops as much as possible.

If the value is too small, it is easy to perform backward handover to the original cell, toggle handover occurs.
Configuration Rule and Adjustment Suggestion
If the value is too large, it is not easy to perform backward handover to the original cell.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 101 of 134

Neighbour cell for emergency handover

Full Name Neighbour cell for emergency handover

Abbreviation NCellWindowEmerg

Managed Object Handover Control

3GPP Name Hreqave

3GPP Reference 3GPP TS 45.008

In the GSM system, BSC makes handover decision according to the measurement data. To avoid the negative impact
of burst measurement values resulting from complicated radio transmission, BSC, when making handover decision,
no longer uses the original measurement data but uses a series of average values of the measurement data.
This parameter indicates the size of the window used for calculating the average value of signal strength of the
Description neighbour cell with emergent handover. The size is the number of samples used in averaging.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 4

Number of samples should be enough for ensuring


the preciseness of handover decision, and for initiating handover
Default Value Configuration Reason
as early as possible to avoid call drop when the signal is poor during
communication.

If the value is set too small and samples of handover decision are too few, the handover decision is incorrect.
Configuration Rule and Adjustment Suggestion If the value is set too large, it takes a long time to make handover decisions, which is likely to result in call drops
caused by handover delays.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink rapid quality drop THS

Full Name Downlink rapid quality drop THS

Abbreviation DLQualRapidHoThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates the threshold of downlink rapid quality drop.


Description This parameter is supported from version 6.20.614b.

Instance Cell

Value Range and Step 8..70

Unit N/A

Default Value 60

Default Value Configuration Reason experience value

The smaller is the threshold and value N, the


Configuration Rule and Adjustment Suggestion easier is the quality handover, the easier is the handover of MS out
of poor quality cell.

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 102 of 134

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Downlink rapid quality drop Value N

Full Name Downlink rapid quality drop Value N

Abbreviation DLQualRapidHoN

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter indicates the value N of downlink rapid quality drop.


Description This parameter is supported from version 6.20.614b.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 2

Default Value Configuration Reason experience value

The smaller is the threshold and value N, the


Configuration Rule and Adjustment Suggestion easier is the quality handover, the easier is the handover of MS out
of poor quality cell.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Quality weight of recent measure value

Full Name Quality weight of recent measure value

Abbreviation QualityAverageWeight

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 103 of 134

The quality weight of measurement report is represented by 20 parameters. The average uplink quality and average downlink quality use
this group of parameters.The first parameter indicates the weight of the latest measurement report.For example, if quality weight is 100,
80, 60, or 40, and the quality average window size is 4, QAVG=(Q1*100+Q2*80+Q3*60+Q4*40)/(100+80+60+40) (Q1 is the latest
measurement value of quality) when quality is averaged.

Instance Cell

Value Range and Step 1..100

Unit N/A

Default Value [100,100,100,100,100,100,100,100,100,100,100,100,100,100,100,100,100,100,100,100]

Default Value Configuration


Reason The default value uses the same weight.

The latest measurement report is set as the


Configuration Rule and
larger weight. The handover success rate, call drops due to handover,
Adjustment Suggestion
and RQ reflect the effect of parameter setting.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Level weight of recent measurement value level

Full Name Level weight of recent measurement value level

Abbreviation LevelAverageWeight

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter describes the level weight of recent Nth measurement value.

Instance Cell

Value Range and Step 1..100

Unit N/A

Default Value [100,100,100,100,100,100,100,100,100,100,100,100,100,100,100,100,100,100,100,100]

This parameter is newly added in the 61 version.


Default Value Configuration
All levels keep the same weight by default so that the handover index
Reason
does not fluctuate before and after upgrade.

Configuration Rule and If necessary, it is recommended to adjust the


Adjustment Suggestion weight of the latest level to the highest.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 104 of 134

Parameter Modifying Version N/A

Parameter Modifying Detail None

The load of HO from FR to HR(V3)

Full Name The load of HO from FR to HR(V3)

Abbreviation frtoamrhrholoadthr

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter specifies a load threshold for initiating FR/HR (V3) handover. When the load of a cell reaches the
threshold, an FR/HR (V3) handover is initiated to obtain more channel resources and improve the system capacity.
This threshold must be equal to or less than FrToHrHoLoadThr.
Description Load formula: LOAD = Number of busy channels in the cell 100/(Number of busy channels + Number of idle channels)

Instance Cell

Value Range and Step 20..100

Unit %

Default Value 80

When the cell load reaches 80%, the cell is


Default Value Configuration Reason regarded as a busy cell. In this case, handover from FR to HR (V3)
can be performed to enhance system capacity.

This parameter is valid only when the FRTHRHOSupport switch is enabeld in the cell.
Configuration Rule and Adjustment The larger the value is, the higher is the cell load required for initiating FR->HR(V3) handover, and the ;less is the opportunity
Suggestion for handover.
If the value is too small, the number of intra-cell handovers increases.

Change Mode Offline

Related features ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters FRTHRHOSupport


FrToHrHoLoadThr

This parameter is valid only when the FRTHRHOSupport switch is enabled in the cell.
Relationship
FrToHrHoLoadThr>=FrToAmrHrHoLoadThr

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.614d

Parameter Modifying Detail New

The load of HO from FR to HR(V1)

Full Name The load of HO from FR to HR(V1)

Abbreviation frtohrholoadthr

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter specifies a load threshold for initiating FR/HR (V1) handover. When the load of a cell reaches the
threshold, an FR/HR (V1) handover is initiated to obtain more channel resources and improve the system capacity.
This threshold must be equal to or greater than FrToAmrHrHoLoadThr.
Description Load formula: LOAD = Number of busy channels in the cell 100/(Number of busy channels + Number of idle channels)

Instance Cell

Value Range and Step 20..100

Unit %

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 105 of 134

Default Value 90

When the cell load reaches 80%, the cell is


Default Value Configuration Reason regarded as a busy cell. In this case, handover from FR to HR (V1)
can be performed to enhance system capacity.

This parameter is valid only when the FRTHRHOSupport switch is enabeld in the cell.
Configuration Rule and Adjustment The larger the value is, the higher is the cell load required for initiating FR->HR(V1) handover, and the less is the opportunity
Suggestion for handover.
If the value is too small, the number of intra-cell handovers increases.

Change Mode Offline

Related features ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters FRTHRHOSupport


FrToAmrHrHoLoadThr

This parameter is valid only when the FRTHRHOSupport switch is enabled in the cell.
Relationship
FrToHrHoLoadThr>=FrToAmrHrHoLoadThr

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.614d

Parameter Modifying Detail None

The quality of HO from FR to HR

Full Name The quality of HO from FR to HR

Abbreviation frhoquathr

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

When the cell load reaches a certain level, handover from FR to HR should be initiated, so as to get more channel
resources and enhance system capacity. However, the quality of the chosen FR call must meet a certain requirement.
This parameter determines the quality threshold for initiating handover from FR to HR.
Description The value of this parameter should be smaller than that of HrHoQuaThr or AmrHrHoQuaThr.

Instance Cell

Value Range and Step 0..70

Unit N/A

Default Value 10

The voice quality must meet a certain requirement


Default Value Configuration Reason after handover from FR to HR. Therefore, this parameter can be configured
to a relatively small value.

Configuration Rule and Adjustment The lower the threshold, the higher the requirement
Suggestion on quality.

Change Mode Offline

Related features ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters FRTHRHOSupport


AmrHrHoQuaThr
HrHoQuaThr

This parameter is valid only when the FRTHRHOSupport switch is enabled in the cell.
Relationship HrHoQuaThr>FrHoQuaThr
AmrHrHoQuaThr>FrHoQuaThr

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 106 of 134

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.614d

Parameter Modifying Detail None

The quality of HO from HR(V1) to FR

Full Name The quality of HO from HR(V1) to FR

Abbreviation hrhoquathr

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter specifies a quality threshold for initiating intra-cell HR (V1)/FR handover. If the speech quality during an
HR call is too poor, an intra-cell HR (V1)/FR handover can be initiated although the other handover conditions are not
met.
Description This threshold must be greater than FrHoQuaThr.

Instance Cell

Value Range and Step 8..70

Unit N/A

Default Value 39

The voice quality is acceptable if it is higher


Default Value Configuration Reason than this threshold. If it is less than this threshold, handover should
be initiated to improve user experience.

The larger the HrHoQuaThr parameter is, the higher is the tolerbility for the quality error bit rate of HR services, the
smaller is the possibility of initiating HR(V1)->FR quality handover.
Configuration Rule and Adjustment Suggestion
The smaller the HrHoQuaThr parameter is, the lower is the tolerbility for the quality error bit rate of HR services, the
larger is the possibility of initiating HR(V1)->FR quality handover.

Change Mode Offline

Related features ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters HRTFRHOSupport


FrHoQuaThr

This parameter is valid only when the FRTHRHOSupport switch is enabled in the cell.
Relationship
HrHoQuaThr>=FrHoQuaThr

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.614d

Parameter Modifying Detail None

The quality of HO from HR(V3) to FR

Full Name The quality of HO from HR(V3) to FR

Abbreviation amrhrhoquathr

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter specifies a quality threshold for initiating intra-cell HR (V3)/FR handover. If the speech quality during an
AMR HR call is too poor, an intra-cell HR (V3)/FR handover can be initiated although the other handover conditions are
not met.
Description This threshold must be greater than FrHoQuaThr.

Instance Cell

Value Range and Step 8..70

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 107 of 134

Unit N/A

Default Value 39

The voice quality is acceptable if it is higher


Default Value Configuration Reason than this threshold. If it is less than this threshold, handover should
be initiated to improve user experience.

The larger the AmrHrHoQuaThr parameter is, the higher is the tolerbility for the quality error bit rate of HR services, the
Configuration Rule and Adjustment smaller is the possibility of initiating HR(V3)->FR quality handover.
Suggestion The smaller the AmrHrHoQuaThr parameter is, the lower is the tolerbility for the quality error bit rate of HR services, the
larger is the possibility of initiating HR(V4)->FR quality handover.

Change Mode Offline

Related features ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters HRTFRHOSupport


FrHoQuaThr

This parameter is valid only when the FRTHRHOSupport switch is enabled in the cell.
Relationship
AmrHrHoQuaThr>FrHoQuaThr

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.614d

Parameter Modifying Detail None

P value of load and quality handover

Full Name P value of load and quality handover

Abbreviation loadandqualhop

Managed Object Handover Control

3GPP Name N1..N8,P1..P8

3GPP Reference 3GPP TS 45.008

For the handovers between FR and HR caused by load and quality changes, if P out of the N values (the latest average
N values of signal quality) satisfy the threshold requirements, handover can be initiated.
Description This parameter value should be smaller than or equal to LoadAndQualHoN.

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 3

It is recommended to set the default value


Default Value Configuration Reason
to 3, so as to ensure the accuracy and rapidness of handover.

If the value is too small, it is very easy to satisfy the condition of handover decision, handover is too frequent.
Configuration Rule and Adjustment Suggestion
If the value is too large, it is very difficult to satisfy the condition of handover decision.

Change Mode Offline

Related features ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters FRThrHoSupport,


LoadAndQualHoN

This parameter takes effect until the FR->HR switch based on load is enabled.
Relationship
This parameter value should be smaller than or equal to LoadAndQualHoN.

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 108 of 134

Parameter Modifying Version N/A

Parameter Modifying Detail None

N value of load and quality handover

Full Name N value of load and quality handover

Abbreviation loadandqualhon

Managed Object Handover Control

3GPP Name N1..N8,P1..P8

3GPP Reference 3GPP TS 45.008

For the handovers between FR and HR caused by load and quality changes, if P out of the N values (the latest average
N values of signal quality) satisfy the threshold requirements, handover can be initiated.
Description This parameter value should be larger than or equal to LoadAndQualHoP.

Instance Cell

Value Range and Step 1..21

Unit N/A

Default Value 4

It is recommended to set the default value


Default Value Configuration Reason
to 4, so as to ensure the accuracy and rapidness of handover.

If the value is set too small and samples of handover decision are too few, the handover decision is incorrect.
Configuration Rule and Adjustment Suggestion If the value is set too large, it takes a long time to make handover decisions, which is likely to result in call drops
caused by handover delays.

Change Mode Offline

Related features ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters FRThrHoSupport,


LoadAndQualHoP

This parameter takes effect until the FR->HR switch based on load is enabled.
Relationship
This parameter value should be larger than or equal to LoadAndQualHoP.

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Penalty time for handover caused


by interference

Penalty time for handover caused


Full Name by interference

Abbreviation InterfHoPenalTime

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter determines the penalty time of the interference handover in a cell, including the penalty for handover
Description failure and continuous intra-cell handovers.

Instance Cell

Value Range and Step 1..255

Unit N/A

Default Value 7

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 109 of 134

Default Value Configuration Reason If the pre-processed measurement reports are


used for pre-processing, this parameter is configured to 7. In this
case, the penalty time is long enough. If common measurement reports
are used, the value of this parameter should be configured to a larger
value.

Setting of this parameter should be in consideration of the pre-processing period for measurement reports. If the
Configuration Rule and Adjustment Suggestion value is too small, failure or invaid handover is prone to occur continuously.
If the value is too large, intra-cell handover may not be performed timely.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710b

Parameter Modifying Detail New

Interference band requirement for intracell handover caused by interference

Full Name Interference band requirement for intracell handover caused by interference

Abbreviation InterfBandforHo

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter determines the maximum interference band required by the intra-cell interference handover. If a
channel does not meet this interference band (the value of interference band is not larger than the value of this
Description parameter), the intra-cell handover cannot be implemented.

Instance Cell

Value Range and Step 1..5

Unit N/A

Default Value 2

If the value of interference band is not larger


than 2, it indicates that the interference in this channel is small
Default Value Configuration Reason
enough. In this case, the channel can be used for intra-cell interference
handover.

Usually, the value of this parameter is not


modified. If this parameter is configured to a large value, the handover
Configuration Rule and Adjustment Suggestion
success rate will be affected. If this parameter is configured to
a small value, no channel is allocated during intra-cell handover.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710b

Parameter Modifying Detail New

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 110 of 134

Prefer layer for traffic handover

Full Name Prefer layer for traffic handover

Abbreviation TrafficHoPreferLayer

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines the preferred layer during traffic handover.

Instance Cell

0:Preferred when the adjacent cell and the local cell are on the same layer
1:Preferred when the adjacent cell is on the upper layer of the local cell
2:Preferred when the adjacent cell is on the lower layer of the local cell
3:Preferred when the adjacent cell is on an undefined layer
Value Range and Step 255:No preferred layer

Unit N/A

Default Value 255

The preferred layer and value are configured


Default Value Configuration Reason
according to the network condition. By default, this function is disabled.

It is required to configure a preferred layer


during traffic handover according to the network condition. Usually,
Configuration Rule and Adjustment Suggestion the system is prior to switch the traffic to the layer with low traffic.
In most cases, the layer is a lower layer or same layer for absorbing
traffic.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710a

Parameter Modifying Detail New

PBGT offset of prefer layer for traffic handover

Full Name PBGT offset of prefer layer for traffic handover

Abbreviation TrafficHoLayerOffset

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines the specific value for the preferred layer during traffic handover.

Instance Cell

Value Range and Step 0..48

Unit dB

Default Value 24

The preferred layer and value are configured


Default Value Configuration Reason
according to the network condition. By default, this function is disabled.

PBGT offset indicates the priority of the preferential layer. The larger the offset is, the easier is to queue up at the front.
Configuration Rule and Adjustment Suggestion
Whereas, the value should not be too large, to avoid handover to the cell with poor signal.

Change Mode Offline

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 111 of 134

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710a

Parameter Modifying Detail New

Prefer band for traffic handover

Full Name Prefer band for traffic handover

Abbreviation TrafficHoPreferBand

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines the preferred frequency band during traffic handover.

Instance Cell

0: P-GSM Preferred
1: E-GSM Preferred
2: DCS1800 Preferred
4: GSM1900 Preferred
7: GSM850 Preferred
Value Range and Step 255: No Prefer

Unit N/A

Default Value 255

The preferred frequency band and value are


Default Value Configuration Reason configured according to the network condition. By default, this function
is disabled.

It is required to configure a preferred layer


during traffic handover according to the network condition. Usually,
Configuration Rule and Adjustment Suggestion the system is prior to switch the traffic to the layer with low traffic.
In most cases, the layer is a lower layer or same layer for absorbing
traffic.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710a

Parameter Modifying Detail New

PBGT offset of prefer band for traffic handover

Full Name PBGT offset of prefer band for traffic handover

Abbreviation TrafficHoBandOffset

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 112 of 134

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines the specific value for the preferred frequency band during traffic handover.

Instance Cell

Value Range and Step 0..48

Unit Db

Default Value 24

The preferred frequency band and value are


Default Value Configuration Reason configured according to the network condition. By default, this function
is disabled.

PBGT offset indicates the priority of the preferential layer. The larger the offset is, the easier is to queue up at the front.
Configuration Rule and Adjustment Suggestion
Whereas, the value should not be too large, to avoid handover to the cell with poor signal.

Change Mode Offline

Related features ZGO-02-02-007 Traffic Based Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.710a

Parameter Modifying Detail New

The threshold for starting Downlink Rapid handover

Full Name The threshold for starting Downlink Rapid handover

Abbreviation DLRapidHoStartThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter determines the threshold of TCH downlink level in the case of rapid handover. Downlink level rapid
handover is a new handover algorithm for the high-speed railway scenario. In this scenario, it is required to configure
different offsets for high, medium, and low speeds to adapt to rapid attenuation of the downlink level. In addition,
Description handover is only triggered between cells in the dedicated high-speed railway network.

Instance Cell

Value Range and Step 0..63

Unit N/A

Default Value 63

It is a functional parameter and is configured


Default Value Configuration Reason to 63 by default. Only when downlink rapid handover is enabled, the
system will implement handover judgment for adjacent cells.

It is required to configure this parameter


Configuration Rule and Adjustment Suggestion
according to the network planning.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 113 of 134

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

High speed threshold

Full Name High speed threshold

Abbreviation HighSpeedThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter determines whether a subscriber moves at high speed. If the moving speed of a subscriber is larger
Description than this threshold, the system considers this scenario as a high-speed scenario.

Instance Cell

Value Range and Step 0..255

Unit N/A

Default Value 25

According to experienced values, the system


Default Value Configuration Reason considers a scenario as a high-speed scenario if the moving speed
of a subscriber is faster than 250 km/h.

Currently, this parameter is not used and need


Configuration Rule and Adjustment Suggestion
not be adjusted.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Middle speed threshold

Full Name Middle speed threshold

Abbreviation MidSpeedThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter determines whether a subscriber moves at medium speed. If the moving speed of a subscriber is larger
Description than this threshold, the system considers this scenario as a medium-speed scenario.

Instance Cell

Value Range and Step 0..255

Unit N/A

Default Value 15

Default Value Configuration Reason According to experienced values, the system

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 114 of 134

considers a scenario as a medium-speed scenario if the moving speed


of a subscriber is faster than 150 km/h.

Currently, this parameter is not used and need


Configuration Rule and Adjustment Suggestion
not be adjusted.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

The minimum interval of direction handover

Full Name The minimum interval of direction handover

Abbreviation DirHoMinInterval

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

To prevent an MS, which is handed over to a cell during a previous directional handover, from being immediately
handed over to another cell (usually occurring in boundary regions between two cells), the system defines this
parameter to avoid frequent handovers between cells and impacts on communication quality and system
performance.
This parameter specifies a time interval. An additional handover of an MS is allowed only when the time since the
previous handover is longer than this interval. This parameter only influences inter-cell handovers. It does not affect
intra-cell handovers or intra-cell concentric handovers.
Description The default parameter value can be set to 5.

Instance Cell

Value Range and Step 0..31

Unit N/A

Default Value 5

Default Value Configuration Reason experience value

Currently, this parameter is not used and need


Configuration Rule and Adjustment Suggestion
not be adjusted.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

The ncell offset for downlink rapid handover

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 115 of 134

Full Name The ncell offset for downlink rapid handover

Abbreviation DLRapidHoNcellOffset

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

The current scenario is a high-speed scenario or the last handover is a handover with specific direction.
When the system performs sorting in the target cell, with this offset, handover to the adjacent cell configured as a high-
speed dedicated
Description network cell is easier.

Instance Cell

Value Range and Step 0..60

Unit N/A

Default Value 24

The meaning of 24 is the same as that of 0.


Default Value Configuration Reason This parameter is currently not used and will be configured in the
future according to network planning.

Currently, this parameter is not used and need


Configuration Rule and Adjustment Suggestion
not be adjusted.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

The offset of ncell in the same direction

Full Name The offset of ncell in the same direction

Abbreviation SameDirNcellOffset

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

The last handover is a handover with specific direction. When the system performs sorting in the target cell, with this
Description offset, handover to the target cell with the same direction as that of the handover is easier.

Instance Cell

Value Range and Step 0..60

Unit N/A

Default Value 24

The meaning of 24 is the same as that of 0.


Default Value Configuration Reason This parameter is currently not used and will be configured in the
future according to network planning.

Currently, this parameter is not used and need


Configuration Rule and Adjustment Suggestion
not be adjusted.

Change Mode Offline

Related features N/A

Related Parameters N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 116 of 134

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Allow signal quality handover on TCH(High speed)

Full Name Allow signal quality handover on TCH(High speed)

Abbreviation BepHoControl_H

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow signal quality handover on TCH(High speed)

Instance Cell

0: Off
Value Range and Step 1: On

Unit N/A

Default Value 0

Default Value Configuration


Reason This is a newly-added handover function that may be overlapped with the downlink quality handover.

Configuration Rule and


Adjustment Suggestion The value is set and adjusted as required.

Change Mode Offline

Related features N/A

Related Parameters MeanBEPHoThs,MeanBEPHoP,MeanBEPHoN,CVBEPHoThs,CVBEPHoP,CVBEPHoN

Relationship None

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow signal quality handover on TCH(Middle speed)

Full Name Allow signal quality handover on TCH(Middle speed)

Abbreviation BepHoControl_M

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow signal quality handover on TCH(High speed)

Instance Cell

0: Off
Value Range and Step 1: On

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 117 of 134

Unit N/A

Default Value 0

Default Value Configuration


Reason This is a newly-added handover function that may be overlapped with the downlink quality handover.

Configuration Rule and


Adjustment Suggestion The value is set and adjusted as required.

Change Mode Offline

Related features N/A

Related Parameters MeanBEPHoThs,MeanBEPHoP,MeanBEPHoN,CVBEPHoThs,CVBEPHoP,CVBEPHoN

Relationship None

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Allow signal quality handover on TCH(Low speed)

Full Name Allow signal quality handover on TCH(Low speed)

Abbreviation BepHoControl_L

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Allow signal quality handover on TCH(High speed)

Instance Cell

0: Off
Value Range and Step 1: On

Unit N/A

Default Value 0

Default Value Configuration


Reason This is a newly-added handover function that may be overlapped with the downlink quality handover.

Configuration Rule and


Adjustment Suggestion The value is set and adjusted as required.

Change Mode Offline

Related features N/A

Related Parameters MeanBEPHoThs,MeanBEPHoP,MeanBEPHoN,CVBEPHoThs,CVBEPHoP,CVBEPHoN

Relationship None

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Handover Threshole of Mean Bit Error Probability on TCH

Full Name Handover Threshole of Mean Bit Error Probability on TCH

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 118 of 134

Abbreviation MeanBEPHoThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Handover Threshole of Mean Bit Error Probability on TCH

Instance Cell

Value Range and Step 0..31

Unit N/A

Default Value 9

Default Value Configuration Reason This is a newly-added handover function that may be overlapped with the downlink quality handover.

Configuration Rule and Adjustment Suggestion Adjust in accordance with network environment

Change Mode Offline

Related features N/A

Related Parameters BepHoControl

Relationship None

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Handover P Number of Mean Bit Error Probability on TCH

Full Name Handover P Number of Mean Bit Error Probability on TCH

Abbreviation MeanBEPHoP

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Handover P Number of Mean Bit Error Probability on TCH

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 2

Default Value Configuration Reason empirical value

Configuration Rule and Adjustment


Suggestion It is recommended that this parameter be not adjusted.

Change Mode Offline

Related features N/A

Related Parameters BepHoControl,MeanBEPHoN

Relationship P<N

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 119 of 134

Parameter Modifying Detail None

Handover N Number of Mean Bit Error Probability on TCH

Full Name Handover N Number of Mean Bit Error Probability on TCH

Abbreviation MeanBEPHoN

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Handover N Number of Mean Bit Error Probability on TCH

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 3

Default Value Configuration Reason empirical value

Configuration Rule and Adjustment Suggestion It is recommended that this parameter be not adjusted.

Change Mode Offline

Related features N/A

Related Parameters BepHoControl,MeanBEPHoP

Relationship P<N

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Handover Threshole of CV Bit Error Probability on TCH

Full Name Handover Threshole of CV Bit Error Probability on TCH

Abbreviation CVBEPHoThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Handover Threshole of CV Bit Error Probability on TCH

Instance Cell

Value Range and Step 0..7

Unit N/A

Default Value 4

Default Value Configuration Reason This is a newly-added handover function that may be overlapped with the downlink quality handover.

Configuration Rule and Adjustment Suggestion Adjust in accordance with network environment

Change Mode Offline

Related features N/A

Related Parameters BepHoControl

Relationship None

Related Interfaces N/A

Impact on Equipment 0

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 120 of 134

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Handover P Number of CV Bit Error Probability on TCH

Full Name Handover P Number of CV Bit Error Probability on TCH

Abbreviation CVBEPHoP

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Handover P Number of CV Bit Error Probability on TCH

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 2

Default Value Configuration Reason empirical value

Configuration Rule and Adjustment Suggestion It is recommended that this parameter be not adjusted.

Change Mode Offline

Related features N/A

Related Parameters BepHoControl,CVBEPHoN

Relationship P<N

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Handover N Number of CV Bit Error Probability on TCH

Full Name Handover N Number of CV Bit Error Probability on TCH

Abbreviation CVBEPHoN

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Handover N Number of CV Bit Error Probability on TCH

Instance Cell

Value Range and Step 1..20

Unit N/A

Default Value 3

Default Value Configuration Reason empirical value

Configuration Rule and Adjustment Suggestion It is recommended that this parameter be not adjusted.

Change Mode Offline

Related features N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 121 of 134

Related Parameters BepHoControl,CVBEPHoP

Relationship P<N

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

If support intra-handover from FR to HR due to high load

Full Name If support intra-handover from FR to HR due to high load

Abbreviation frTHrHoSupport

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

It indicates if FR->HR handover based on load is supported, When the load of a cell increases, handover can be
Description applied to improve the utilization ratio of the radio channel.

Instance Cell

0: Off
Value Range and Step 1: On

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

When the cell needs to enable FR->HR handover, enable this switch. This function is able to improve the utilization of
Configuration Rule and Adjustment Suggestion
radio channels when the cell load is increased.

Change Mode Offline

Related features ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.614d

Parameter Modifying Detail None

If support intra-handover from HR to FR due to bad quality

Full Name If support intra-handover from HR to FR due to bad quality

Abbreviation hrTFrHoSupport

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter determines whether to support HR-FR handover based on quality. In the case of poor HR voice quality,
Description the HR-FR handover can be triggered to improve voice quality.

Instance Cell

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 122 of 134

Value Range and Step 0: Off


1: On

Unit N/A

Default Value 0

Default Value Configuration Reason The functional Switch, default: close

When HR-FR handover is required for a cell,


Configuration Rule and Adjustment Suggestion enable this switch. Poor HR voice quality can be improved by the handover
to FR channel.

Change Mode Offline

Related features ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.614d

Parameter Modifying Detail None

Is Dual-Frequency Traffic Handover Support

Full Name Is Dual-Frequency Traffic Handover Support

Abbreviation DualFreqHoSup

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines whether to switch to the dual-frequency traffic mode.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason The switch is disabled normally.

Enable this switch if related cells associated with the dual-frequency network are configured and these cells are used
Configuration Rule and Adjustment Suggestion
to absorb traffic.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Dual-Frequency Handover Parameter N

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 123 of 134

Full Name Dual-Frequency Handover Parameter N

Abbreviation DualFreqHoN

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter sets the N value for a dual-frequency network handover.

Instance Cell

Value Range and Step 1..10

Unit N/A

Default Value 3

Default Value Configuration Reason To ensure the handover stability and reliability

Configuration Rule and Adjustment Suggestion Set a lower value to quicken the decision making process.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Dual-Frequency Handover Parameter P

Full Name Dual-Frequency Handover Parameter P

Abbreviation DualFreqHoP

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter sets the P value for a dual-frequency handover.

Instance Cell

Value Range and Step 1..10

Unit N/A

Default Value 2

Default Value Configuration Reason To ensure the handover stability and reliability

Configuration Rule and Adjustment Suggestion Set a lower value to quicken the decision making process.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 124 of 134

Parameter Modifying Version N/A

Parameter Modifying Detail None

Dual-Frequency Handover TA Threshold

Full Name Dual-Frequency Handover TA Threshold

Abbreviation DualFreqHoTAThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter sets the threshold of dual-frequency handover TA.

Instance Cell

Value Range and Step 0..63

Unit N/A

Default Value 63

Default Value Configuration Reason Normally, the related cell in the dual-frequency network has a similar coverage with the local cell.

Configuration Rule and Adjustment Suggestion Set a lower value if the coverage of the related cell is smaller than the local cell.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Dual-Frequency Handover RxLevel Threshold

Full Name Dual-Frequency Handover RxLevel Threshold

Abbreviation DualFreqHoDLThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter sets the threshold of dual-frequency handover level.

Instance Cell

Value Range and Step 0..63

Unit N/A

Default Value 30

Default Value Configuration Reason The level to ensure proper operation of a cell

Configuration Rule and Adjustment Suggestion Set a higher threshold if the QoS is not improved after the handover to sub-cell 1.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 125 of 134

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Circuit data handover control

Full Name Circuit data handover control

Abbreviation CSDATAHOControl

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description This parameter determines whether handover is allowed for CS data traffic.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 1

Default Value Configuration Reason Handover is allowed normally.

Configuration Rule and Adjustment


Suggestion Disable this parameter if CS data services are affected by the handover.

Change Mode Offline

Related features N/A

Related Parameters vsDataGBssFunction.CSDATAHOControl

Relationship Handover can be done only if

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Back to Source Cell when PBGT Handover

Full Name Back to Source Cell when PBGT Handover

Abbreviation PBGTHoBacktoSource

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

For a PBGT handover, this parameter determines whether only levels meeting the requirement are allowed for HO
Access. If the level does not meet the requirement, the system does not send a PHY Info message, and sends the
Description handover failure message for the MS to return to the source channel.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 126 of 134

Default Value Configuration Reason Not supported by default

Configuration Rule and Adjustment Suggestion Enable this parameter when required.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Back to Source Cell when Other


Handover

Back to Source Cell when Other


Full Name Handover

Abbreviation OtherHoBacktoSource

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

For non-PBGT handovers, this parameter determines whether only levels meeting the requirement are allowed for HO
Access. If the level does not meet the requirement, the system does not send the PHY Info, and sends the handover
Description failure message for the MS to return to the source channel.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason Not supported by default

Configuration Rule and Adjustment Suggestion Enable this parameter when required.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

HoAccess Require Rxlevel offset

Full Name HoAccess Require Rxlevel offset

Abbreviation HoAccessReqLevOffset

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 127 of 134

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter sets the offset for calculating the level required for handover access. The calculation formula is 110-
Description TargetAverageRxLevel + LinkBalance + (HoAccessReqLevOffset -35).

Instance Cell

Value Range and Step 0..70

Unit N/A

Default Value 45

Default Value Configuration Reason Default: 10 db

Configuration Rule and Adjustment Suggestion Set a greater value if a lower handover detection level is required.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

HoAccess Require Rxlevel Select


Strategy when Other Handover

HoAccess Require Rxlevel Select


Full Name Strategy when Other Handover

Abbreviation OtherHoAccessLevSel

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

For non-PBGT handovers, this parameter sets the strategy used for selecting the levels required by handover access.
The minimum receiving level or (110- TargetAverageRxLevel + LinkBalance + (HoAccessReqLevOffset -35)) can be
Description selected.

Instance Cell

1:Expected uplink level


Value Range and Step 2:Minimum allowed access level

Unit N/A

Default Value 1

Default Value Configuration Reason Default: strategy 1

Configuration Rule and Adjustment Suggestion Use strategy 2 if strategy 1 leads to deteriorated SD indexes.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 128 of 134

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Dual-Frequency Traffic Handover Threshold

Full Name Dual-Frequency Traffic Handover Threshold

Abbreviation DualFreqOverLoadThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

If related cells are configured, when the cell load is greater than the parameter value and the related cell is lower than
Description the parameter value, the system makes a dual-frequency traffic handover decision.

Instance Cell

Value Range and Step 0..100

Unit %

Default Value 70

Default Value Configuration Reason Empirical value

Configuration Rule and Adjustment Suggestion Set a higher threshold if better level is expected after handover to the related cell.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Support handover from HR to FR due to low load

Full Name Support handover from HR to FR due to low load

Abbreviation HRTFRHOSupport2

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Enables/Disables the HR-FR handover function (HR includes HR (v1) and HR (V3)).

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason Generally this function is disabled.

Configuration Rule and Adjustment Suggestion A HR-FR handover can be enabled to improve the conversation quality when the load of a cell is lowered.

Change Mode Offline

Related features ZGO-04-01-005 Interference Rejection Combining (IRC)

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 129 of 134

ZGO-04-01-009 Enhanced IRC

Related Parameters N/A

Relationship N/A

Related Interfaces Abis

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version UR11.2 B.

Parameter Modifying Detail New

The load of HO from HR V1 to FR

Full Name The load of HO from HR V1 to FR

Abbreviation HrToFrHoLoadThr

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

Description Load (low threshold) of a cell that triggers an HR (V1)-FR handover.

Instance Cell

Value Range and Step 0..100

Unit %

Default Value 30

The parameter value is determined by the user experience and the load on a channel. For example, if the load on a
Default Value Configuration Reason
channel is lower than 30, the full rate mode can be applied to improve the user experience.

After a handover to the FR mode, the load on the current channel is increased, and it is possible to reach the load
Configuration Rule and Adjustment Suggestion threshold triggering a handover to the dynamic HR mode. This parameter must be set to a value that can not only
improve the user experience, but also avoid frequent handovers.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters AmrHrToFrHoLoadThr

In the same cell, AmrHRThs >HrToFrHoLoadThr>= AmrHrToFrHoLoadThr


Relationship
FrToHrHoLoadThr> HrToFrHoLoadThr

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

The load of HO from HR V3 to FR

Full Name The load of HO from HR V3 to FR

Abbreviation AmrHrToFrHoLoadThr

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

Description Load (low threshold) of a cell that triggers an HR (V3)-FR handover.

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 130 of 134

Instance Cell

Value Range and Step 0..100

Unit %

Default Value 20

The parameter value is determined by the user experience and the load on a channel. For example, if the load on a
Default Value Configuration Reason
channel is lower than 20, the AMR full rate mode can be applied to improve the user experience.

After a handover to the AMR FR mode, the load on the current channel is increased, and it is possible to reach the load
Configuration Rule and Adjustment Suggestion threshold triggering a handover to the dynamic HR mode. This parameter must be set to a value that can not only
improve the user experience, but also avoid frequent handovers.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters HrToFrHoLoadThr

In the same cell, AmrHRThs >HrToFrHoLoadThr>= AmrHrToFrHoLoadThr


Relationship
FrToAmrHrHoLoadThr> AmrHrToFrHoLoadThr

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

HR to FR handover downlink level start threshold

Full Name HR to FR handover downlink level start threshold

Abbreviation HrToFrHoStartThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

Description Electricity level threshold that triggers an HR-FR handover.

Instance Cell

Value Range and Step 0..63

Unit N/A

Default Value 35

Default Value Configuration Reason The default value is set in accordance with the past experience.

Configuration Rule and Adjustment Suggestion The HR-FR handover is unlikelier to be performed if the parameter value is higher, and vice versa.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship HoDlLevP <= HoDlLevN

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

FR to HR handover downlink level start threshold

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 131 of 134

Full Name FR to HR handover downlink level start threshold

Abbreviation FrToHrHoStartThs

Managed Object Handover Control

3GPP Name N/A

3GPP Reference 3GPP TS 45.008

Description Electricity level threshold that triggers an FR-HR handover.

Instance Cell

Value Range and Step 0..63

Unit N/A

Default Value 35

Default Value Configuration Reason The default value is set in accordance with the past experience.

Configuration Rule and Adjustment Suggestion The FR-HR handover is unlikelier to be performed if the parameter value is higher, and vice versa.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship HoUlQualP <= HoUlQualN

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Back to Source Cell when MSC Controlled Incoming Handover

Full Name Back to Source Cell when MSC Controlled Incoming Handover

Abbreviation MSCHoInHoBack2Source

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description Enables/Disables the back-to-source-cell function when TCH incoming handover is performed.

Instance Cell

0: No
Value Range and Step 1: Yes

Unit N/A

Default Value 0

Default Value Configuration Reason This function is enabled to when the call drop rate is high at he field. By default this parameter is set to 0.

This function is enabled when the call drop rate at the field is high. During the process of handover in from the external,
Configuration Rule and Adjustment Suggestion the source cell is not informed when an MS is handed-over back to its source cell, therefore, the handover indexes of
the source cell may be affected. Generally back-to-source-cell function is recommended to be disabled.

Change Mode Offline

Related features ZGB-02-02-001 Basic Handover

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 132 of 134

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version iBSCV6.20.615b

Parameter Modifying Detail New

Good level and bad quality handover DL Level

Full Name Good level and bad quality handover DL Level

Abbreviation GoodLevBadRQHoDLLev

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

The system triggers the high level and bad quality handover when the downlink level of this cell is higher than the value of
Description this parameter.

Instance Cell

Value Range and Step 0..63

Unit N/A

Default Value 30

By default, the handover due to good level and bad quality is determined when the downlink level of this cell is higher than
Default Value Configuration Reason
-80 dB.

Configuration Rule and Adjustment When it is difficult to initiate a handover due to good level and bad quality, decrease the threshold. After enabling this
Suggestion function, pay attention to the call drop rate. If the call drop rate deteriorates, increase the threshold.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

HoAccess Require CI

Full Name HoAccess Require CI

Abbreviation HoAccessReqCI

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

Description CI ratio required for handover detection

Instance Cell

Value Range and Step 0..255

Unit N/A

Default Value 12

Default Value Configuration Reason According to the lab data, demodulated signals of NB are bad when the receive signals CI is smaller than 12.

Configuration Rule and Adjustment Enable the handover bounce scenario as required. Set a proper CI threshold according to that of the actual frequency
Suggestion point used for testing.

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 133 of 134

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Good level and bad quality handover enable

Full Name Good level and bad quality handover enable

Abbreviation GoodLevBadRQHoEnable

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

This parameter describes whether this cell supports good level and bad quality handover. If the bad quality handover is
determined successfully but there is not a candidate cell, the system determines whether to enable the high level and bad
Description quality handover.

Instance Cell

Value Range and Step 0:No 1:Yes

Unit N/A

Default Value 0

Default Value Configuration Reason By default, the handover due to good level and bad quality is disabled.

According to the DT data, this function can be enabled if call drop frequently occurs in TCH channels due to good level
Configuration Rule and Adjustment
and bad quality. After enabling this function, pay attention to the call drop rate. If the call drop rate deteriorates, disable
Suggestion
this function or modify the "GoodLevBadRQoffSet" or "GoodLevBadRQHoDLLev" parameter.

Change Mode Offline

Related features N/A

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN No

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information Configuration->Handover Control

Parameter Modifying Version N/A

Parameter Modifying Detail None

Penalty time for inter-subcell handover failure

Full Name Penalty time for inter-subcell handover failure

Abbreviation SChoFailPenalTime

Managed Object Handover Control

3GPP Name N/A

3GPP Reference N/A

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017
Handover Control (GHandoverControl) Page 134 of 134

Description This parameter specifies the penalty time in case of inter-subcell handover failure. It can be set separately from the
penalty time for inter-cell handover failure.

Instance Cell

Value Range and Step 1..255

Unit N/A

Default Value 14

Default Value Configuration Reason Consistent with the default value of the parameter hoFailPenalTime

If it is necessary to slow down or speed up cell handover determination, this parameter can be adjusted to lengthen or
Configuration Rule and Adjustment Suggestion
shorten the penalty time for inter-cell handover separately. But too short penalty time is not recommended.

Change Mode Offline

Related features ZGB-02-02-001 Handover Between Macro- and Micro-cells

Related Parameters N/A

Relationship N/A

Related Interfaces N/A

Impact on Equipment 0

Impact on service 0

Negotiation With CN NO

OMC Access Path GUI: Managed Element->GSM Logical Configuration->Cell Information

Parameter Modifying Version N/A

Parameter Modifying Detail None

http://127.0.0.1:8890/document?channelid=2&amp;record=1&amp;resultid=1&amp;prese... 8/28/2017

Вам также может понравиться