Академический Документы
Профессиональный Документы
Культура Документы
Implanted brain electrodes construct the only means to electrically interface with individual neurons in vivo, but
their recording efficacy and biocompatibility pose limitations on scientific and clinical applications. We showed
that nanoelectronic thread (NET) electrodes with subcellular dimensions, ultraflexibility, and cellular surgical
footprints form reliable, glial scarfree neural integration. We demonstrated that NET electrodes reliably de-
tected and tracked individual units for months; their impedance, noise level, single-unit recording yield, and
the signal amplitude remained stable during long-term implantation. In vivo two-photon imaging and postmor-
magnitude to 1015 Nm2, which brought down the probe-tissue inter- dimensions by using a temporary engaging mechanism (Fig. 2A) and
facial force to the nanonewton range (fig. S3), on par with the single- shuttle devices made of carbon fibers and tungsten microwires with diam-
cell traction forces (27). eters as small as 7 mm (Fig. 2B). The engaging mechanism was enabled
The ultraflexibility of the NET probes mechanically precluded their by a micropost at the end of each shuttle device fabricated using focused
self-supported penetration through brain tissue. Previous strategies for ion beam (FIB) (fig. S4). During delivery, the micropost engaged into
delivering flexible probes included temporarily altering the probes ri- the microhole (Fig. 2, C to E) and pulled the NET probe to the desired
gidity (20) and, more commonly, temporarily attaching the probe to a depth (movie S1), after which the shuttle device disengaged and
rigid shuttle device (18, 19, 23, 2831). However, most shuttle devices retracted (Materials and Methods). The overall insertion footprint
used in previous studies had dimensions larger than 100 mm, which was as small as ca. 10 mm across (Fig. 2, D and E), which led to only
were significantly larger than the dimensions of the NET probes and cellular-sized surgical damage, as evidenced by little bleeding (Fig. 2,
resulted in unrecoverable damage and persistent scarring (24, 25). We F and G) and small insertion force (fig. S4). Taking advantage of
reduced the implantation footprints by about 10-fold to the cellular the ultraflexibility and the ultrasmall dimensions, we accommodated
chronic optical access with NET implants (Fig. 2, H and I), which ber of electrodes that detected unit events and sortable single-unit
allowed for monitoring of the tissue-probe interface by in vivo action potentials (APs) increased in the first 1.5 months and then
two-photon (2P) imaging. The electrical integrity was maintained remained at the same level (Fig. 3B; examples of unit activities that
throughout surgery and the implanted electrodes readily detected include both nonsortable spikes and sortable single-unit APs are
unit activities (Fig. 2J). detailed in fig. S5). The yields of multi-unit (~75%) and sortable
We next evaluated the long-term reliability of the NET probes. We single-unit recording (~25%) were on par with conventional silicon
implanted 16 probes into the somatosensory and visual cortices of seven probes for spontaneous measurement under anesthesia (32), but with
mice, containing a total of 80 of the 96 connected electrodes (83.3% fab- unprecedented chronic stability. Third, we detected sortable AP wave-
rication yield). We performed electrical recording on anesthetized forms from 19 electrodes with average amplitude and signal-to-noise
animals twice a month for 4 months (Materials and Methods). We ob- ratio (SNR) being stable throughout the 4-month period (Fig. 3C).
served that recording performance improved during the initial 1.5 months We followed all 80 electrodes for 4 months and summarized their
and then remained stable for at least another 2.5 months (until the animal- and probe-specific performance over time in table S1 and fig.
conclusion of our experiment period) in the following aspects: First, S5. Although there were variations in the number of functional electro-
the average impedance and the noise level of all 80 electrodes decreased des and the unit detection yield among different animals, stability and
in the first 1.5 months and remained stable (Fig. 3A). Second, the num- consistency in unit detection over time were observed in all animals. As
an example, Fig. 3D shows the bimonthly measurements from the most 1 month and was fully repaired in association with vascular remo-
electrode that detected typical spike events and sortable AP waveforms deling. As shown in Fig. 4 (A and B) and movie S2, both types of NET
with the highest SNR (>30) among all electrodes. The persistently high probes were embedded in capillaries with normal density, morpholo-
SNR of the sortable AP waveforms indicated that the firing neuron re- gy, and an intact BBB by 2 months. We measured the blood flow rate
mained in close proximity to the electrode for the entire duration of the by line scans (Fig. 4, C and D) (35) and obtained similar values next to
chronic recording (33). Combined principal component analysis for all (420 180 mm/s) and away from (450 210 mm/s) the probe (Materials
measurements showed largely overlapping clusters with cluster centers and Methods), confirming that capillary perfusion immediately next to
average position shifts between consecutive measurements equivalent the probe was normal. This is in strong contrast to conventional micro-
to 0.88s of the average cluster distribution (Fig. 3E), suggesting that electrodes where continuous BBB leakage was observed in chronic in vivo
the waveforms were generated by the same neuron. In addition, we re- imaging at the interface (36).
peatedly detected interneuron waveforms from one electrode (fig. S6), We imaged the astrocytes by in vivo staining (Materials and
which were rare events (<10%) and served as a high-probability marker Methods) 3.5 months after implantation around a NET-50 probe
for tracking the same neuron (34). Furthermore, we observed persistent (Fig. 4E and movie S3). We note that the imaged segment was un-
characteristics in AP waveforms, whereas minor trackable changes intentionally folded during implantation with a sub100-mm curva-
occurred for all except one electrode (18 of 19, 94.7%; fig. S7). Signif- ture, which set the upper limit of tissue-probe stress for NET
icantly, in contrast to previous neuron probes where decreasing am- probes. We observed that the astrocytes near the probe surrounded
plitudes were typically observed over time, most of the NET electrodes only capillaries with normal density and morphology (similar to astro-
recorded AP waveforms with nonmonotonic changes in peak-valley cytes from the contralateral hemisphere of the same mouse shown in
amplitude. The recording evidence strongly indicates that the NET fig. S9). We also performed postmortem histology (Materials and
probes form a nondegrading, slowly evolving interface with neurons. Methods) 5 months after implantation and observed normal neuron
To directly investigate the nature of the probe-tissue interface, we density (fig. S10A) and resting microglia (Fig. 4F) near the probe. Re-
monitored capillaries, astrocytes, and neurons around the NET probes markably, direct contact with the probe did not affect the viability of
by in vivo 2P imaging at the implantation sites for up to 3.5 months after neurons, nor did it activate microglia (Fig. 4F) (24). These results show
surgery (Materials and Methods). Figure S8 shows the evolution of the that the NET probes have unprecedented biocompatibility as they
vasculature, showing that the surgical damage led to minor local leakage maintain normal vascular and cellular structures and elicit no observ-
of the blood-brain barrier (BBB) upon implantation, which lasted for at able chronic tissue reactions at the interface.
To reveal the evolution of the neural interface, we repeatedly imaged cal leakage that results in signal attenuation. However, the possible wa-
neurons in the vicinity of both types of NET probes up to 3 months after ter absorptioninduced leakage did not affect our long-term recording
implantation and compared their locations relative to a few representa- performance, mostly because it did not induce structural damage of the
tive neurons and capillaries as position markers (movies S4 and S5 and NET as shown above, likely due to the improved adhesion between
Fig. 4, G to J). We observed that all neurons initially imaged near the layers and reduced stress. Furthermore, NET probes were soaked for
probe were identified in later imaging sessions, which further proved several days in phosphate-buffered saline (PBS) and other water solu-
that the NET probes did not induce chronic neuronal loss. Further- tions before implantation, which preconditioned the SU-8 film to a
more, although most neurons were relatively stationary, some show saturated water absorption of 3.3% (40), such that no signal attenuation
slow migrations (up to ca. 10 mm) over the course of a few weeks was observed after implantation. Consistent with no structural deterio-
(Fig. 4, I and J). Notably, we observed no preference in their migration ration, electrochemical impedance spectroscopy (EIS) showed a high
trajectories for moving toward or away from the NET probes. impedance, moderately capacitive circuit over a large frequency range
(fig. S11), and little cross-talk was observed from adjacent electrodes
(fig. S12).
DISCUSSION A very recent study reported stable long-term recording in mice
The ultraflexibility of the NET probe prohibits conveniently advancing using mesh electrodes on a similar device platform (31). The con-
to and recording from more than one brain region using schemes simi- sistency between their study and ours strongly supports the validity
attenuation through the capacitive coupling between the interconnects probe reached the desired depth, the shuttle device was retracted,
and the conductive medium surrounding the probe, which was and the neural probe was released and left embedded in the brain
determined to be about 500 nm for our probe geometry and material. tissue. Because the volume of both the shuttle device and the neural
Platinum or gold was used for electrodes (size: 30 mm 30 mm for NET- probe was minimized to reduce tissue damage, the delivery process
50 and 10 mm 20 mm for NET-10) and interconnects, respectively, was delicate. A few experimental details are important to the success
both with a thickness of 100 nm. The different sizes and materials used of the delivery. First, the anchor post of the shuttle device needs to be
for the electrodes contributed to most of the variation in impedance, as microfabricated precisely according to the well-defined cylindrical
shown in Fig. 3A. After fabrication, a 33-pin flexible flat connectors shape as designed, so that it can fit into the engaging hole on the probe,
(FFC) (series 502598, Molex) was mounted on the matching contact can have sufficient mechanical strength for the delivery, and can be
pads on the Si substrate. The implantable section of the probe was then retracted out of the brain without pulling the probe out with it. Second,
soaked in nickel etchant (TFB, Transene Co. Inc.) for 2 to 4 hours at the axial direction of the shuttle device needs to be aligned with the
25C to release the free-standing portion of the probe, while the contact insertion direction to minimize buckling. Third, ACSF needs to be
region remained attached to the substrate. The substrate was cleaved to added to the brain surface as the shuttle device drags the probe into
the desired length before implantation. the brain to float the remaining flexible segment and to minimize fric-
tion between the probe and the brain surface. By controlling the
Shuttle device fabrication and assembly engaging location and the insertion depth, we delivered NET probes
of the same mouse. The blood flow speed was 420 180 mm/s near table S1. Animal- and probe-specific recording performance over time.
the probe, similar to 450 210 mm/s away from the probe. movie S1. A typical implantation procedure of the NET probe.
movie S2. The NET-vasculature integration 2 months after implantation.
movie S3. In vivo 2P images of inactive astrocytes and intact capillary network around a folded
Histological sample preparation segment of a NET-50 probe 3 months after implantation.
Mice were given lethal intraperitoneal injections of 0.15 ml of ketamine movie S4. In vivo 2P images of neurons and two NET-10 probes 1.5 and 2.5 months after
mixed with xylazine [xylazine (10 mg/ml) in ketamine (90 mg/ml)] and implantation.
movie S5. 3D reconstruction of in vivo 2P images of neurons and two NET-10 probes
then perfused intracardially with oxygenated, cold (4C) modified 1.5 months after implantation (the same images as in movie S4, left).
ACSF (2.5 mM KCl, 1.25 mM NaH2PO4, 25 mM NaHCO3, 0.5 mM References (46, 47)
CaCl2, 7 mM MgCl2, 7 mM dextrose, 205.5 mM sucrose, 1.3 mM as-
corbic acid, and 3.7 mM pyruvate) followed by 4% paraformaldehyde
in 0.02 M PBS. Brains were cryoprotected in a 30% sucrose/4% para-
REFERENCES AND NOTES
formaldehyde solution overnight. Tissue was sectioned into 20- to 1. C. M. Gray, P. E. Maldonado, M. Wilson, B. McNaughton, Tetrodes markedly improve the
50-mm slices perpendicular to the probe using a Leica CM1950 cry- reliability and yield of multiple single-unit isolation from multi-unit recordings in cat
ostat (Leica Microsystems). The slices were washed (3 5 min) and striate cortex. J. Neurosci. Methods 63, 4354 (1995).
incubated in hot sodium citrate solution (85C to 95C, 0.01 M in 2. M. A. Nicolelis, D. Dimitrov, J. M. Carmena, R. Crist, G. Lehew, J. D. Kralik, S. P. Wise,
Chronic, multisite, multielectrode recordings in macaque monkeys. Proc. Natl. Acad. Sci.
H2O) for 30 min for antigen retrieval. Then, the slices were washed
24. K. A. Potter, A. C. Buck, W. K. Self, J. R. Capadona, Stab injury and device implantation 41. L. R. Hochberg, G. M. Friehs, J. A. Mukand, M. Saleh, A. H. Caplan, A. Branner, D. Chen,
within the brain results in inversely multiphasic neuroinflammatory and R. D. Penn, J. P. Donoghue, Neuronal ensemble control of prosthetic devices by a
neurodegenerative responses. J. Neural Eng. 9, 046020 (2012). human with tetraplegia. Nature 442, 164171 (2006).
25. T. D. Y. Kozai, Z. Gugel, X. Li, P. J. Gilgunn, R. Khilwani, O. B. Ozdoganlar, G. K. Fedder, 42. A. H. Marblestone, B. M. Zamft, Y. G. Maguire, M. G. Shapiro, T. R. Cybulski, J. I. Glaser,
D. J. Weber, X. T. Cui, Chronic tissue response to carboxymethyl cellulose based D. Amodei, P. B. Stranges, R. Kalhor, D. A. Dalrymple, D. Seo, E. Alon, M. M. Maharbiz,
dissolvable insertion needle for ultra-small neural probes. Biomaterials 35, 92559268 J. M. Carmena, J. M. Rabaey, E. S. Boyden, G. M. Church, K. P. Kording, Physical principles
(2014). for scalable neural recording. Front. Comput. Neurosci. 7, 137 (2013).
26. H. Lee, R. V. Bellamkonda, W. Sun, M. E. Levenston, Biomechanical analysis of silicon 43. B. Tian, J. Liu, T. Dvir, L. Jin, J. H. Tsui, Q. Qing, Z. Suo, R. Langer, D. S. Kohane, C. M. Lieber,
microelectrode-induced strain in the brain. J. Neural Eng. 2, 8189 (2005). Macroporous nanowire nanoelectronic scaffolds for synthetic tissues. Nat. Mater. 11,
27. O. du Roure, A. Saez, A. Buguin, R. H. Austin, P. Chavrier, P. Silberzan, B. Ladoux, 986994 (2012)
Force mapping in epithelial cell migration. Proc. Natl. Acad. Sci. U.S.A. 102, 23902395 44. A. Nimmerjahn, F. Kirchhoff, J. N. D. Kerr, F. Helmchen, Sulforhodamine 101 as a specific
(2005). marker of astroglia in the neocortex in vivo. Nat. Methods 1, 3137 (2004).
28. S. Felix, K. Shah, D. George, V. Tolosa, A. Tooker, H. Sheth, T. Delima, S. Pannu, 45. E. E. Konofagou, Optimization of the ultrasound-induced bloodbrain barrier opening.
Removable silicon insertion stiffeners for neural probes using polyethylene glycol as a Theranostics 2, 12231237 (2012).
biodissolvable adhesive. Conf. Proc. IEEE Eng. Med. Biol. Soc. 2012, 871874 (2012). 46. M. A. L. Nicolelis, A. A. Ghazanfar, B. M. Faggin, S. Votaw, L. M. O. Oliveira, Reconstructing
29. Z. L. Xiang, S.-C. Yen, N. Xue, T. Sun, W. M. Tsang, S. S. Zhang, L.-D. Liao, N. V. Thakor, the engram: Simultaneous, multisite, many single neuron recordings. Neuron 18,
C. Lee, Ultra-thin flexible polyimide neural probe embedded in a dissolvable 529537 (1997).
maltose-coated microneedle. J. Micromech. Microeng. 24, 065015 (2014). 47. P. J. Rousche, D. P. Pivin , J. C. Williams, R. J. Vetter, D. R. Kipke, Flexible polyimide-based
30. T. D. Kozai, D. R. Kipke, Insertion shuttle with carboxyl terminated self-assembled intracortical electrode arrays with bioactive capability. IEEE Trans. Biomed. Eng. 48,
This article is publisher under a Creative Commons license. The specific license under which
this article is published is noted on the first page.
For articles published under CC BY licenses, you may freely distribute, adapt, or reuse the
For articles published under CC BY-NC licenses, you may distribute, adapt, or reuse the article
for non-commerical purposes. Commercial use requires prior permission from the American
Association for the Advancement of Science (AAAS). You may request permission by clicking
here.
Updated information and services, including high-resolution figures, can be found in the
online version of this article at:
http://advances.sciencemag.org/content/3/2/e1601966.full
This article cites 46 articles, 6 of which you can access for free at:
http://advances.sciencemag.org/content/3/2/e1601966#BIBL
Science Advances (ISSN 2375-2548) publishes new articles weekly. The journal is
published by the American Association for the Advancement of Science (AAAS), 1200 New
York Avenue NW, Washington, DC 20005. Copyright is held by the Authors unless stated
otherwise. AAAS is the exclusive licensee. The title Science Advances is a registered
trademark of AAAS