A DEMOLITION
Demolishing brick work manually/ by mechanical means including stacking of serviceable
1 material and disposal of unserviceable material as per direction of Engineer-incharge. Cum

Demolishing cement concrete manually/ by mechanical means including disposal of material


2 Cum

Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats,
3 Cum
architrave, holdfasts etc. complete and stacking

Dismantling of damaged and deformed downpipes, removal of debris and its stacking to storage
4 place - at a construction site landfill and then to the landfill designated by the investor up to
approved distance.
Note - Material auction/selling on owner's behalf and name.

B
I Earth Work
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means
in foundation trenches or drains including dressing of sides and ramming of bottoms, lift upto
1 Cum
1.5 m, including getting out the excavated soil and disposal of surplus excavated soil
as directed.

Filling earth available excavated (excluding rock) in trenches, plinth, sides of foundations etc.
2 in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and Cum
watering.

Supplying and filling in plinth with sand under floors including, watering, ramming
3 Cum
consolidating and dressing complete.

Providing, diluting and injecting chemical emulsion for pre-constructional anti-termite treatment
and creating a chemical barrier under and all-round the column pits, wall trenches, top surface
4 of plinth filling, junction of wall and floor along the external perimeter of building, expansion
joints, surroundings of pipes and conduits etc. complete (plinth area at ground floor level shall
be measured and paid for).
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. Sqm

II STEEL STRUCTURE

Providing Laying, fabricating and fixing in position steel Structure, sanchions & truss, including
straightening, cutting, welding, bending, hoisting, laying in position to the shape and profile
1
required at all levels and heights as per drawing and design and/ or as directed,

2 Framework to support exterior cladding.


3 Retrofitting in existing building strucure.
4 Providing & fixing of Pergola structure as per design and details.

III REINFORCEMENT

Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position
1
and binding all complete.
Thermo-Mechanically Treated bars. Kg

IV CENTRING & SHUTERING


1 FORM WORK
Centering and shuttering including strutting, propping etc. and removal of form for :
concrete wherever applicable with prior approval of the Engineer including
all leads & lifts at all levels, tools & tackles, nails and other consumables.
Suspended floors, roofs, landings, balconies and access platform. Sqm
Extra for sloping roof 20% Extra on Shuttering Sqm
Extra for additional height in centering, shuttering where ever required with adequate
bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a
height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be
measured)

2 Suspended floors, roofs, landing, and balconies (Plan area to be measured). Sqm
height of 1 metre or part thereof (Plan area to be measured).

V PCC & LEAN CONCRETE

Providing and laying in position cement concrete of specified grade excluding the cost of
1
centering and shuttering - All work up to plinth level & under all floors
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
2 Cum
3 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : sqm
6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm
nominal size well rammed and consolidated and grouted with fine sand including finishing
the top smooth
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1
4 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Sqm

VI RCC IN ALL GRADES

1 Providing and laying in position specified grade of reinforced cement concrete excluding
the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :

2 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). cum

VII BRICK WORK

Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in:
1
Cement mortar 1:6 (1 cement : 6 coarse sand) Cum
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth
2 level up to terrace level in all shapes and sizes in:
Cement mortar 1:6 (1 cement : 6 coarse sand) Cum

3 FLY ASH BRICKS


Fly Ash Bricks in superstructure above plinth level up to terrace & parapet level
Cement mortar 1:4 (1 cement :4 coarse sand) Sqm

VIII STONE WORK


Providing and fixing 18mm thick gang saw cut mirror polished premoulded and
prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar
locations of required size of approved shade, colour and texture laid over 20mm thick base
1 cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement,
mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and
polishing to edge to give high gloss finish etc. complete at all levels.

Extra for providing edge moulding to 18mm thick marble stone counters, Vanities
2 etc. including machine polishing to edge to give high gloss finish etc. complete as per
design approved by Engineer-in- Charge.
3 Granite work. metre

IX TILE FLOORING/ SKIRTING


1 Local (vernacular) stone slab flooring over 20 mm (average) thick base laid over and jointed
with grey cement slurry mixed with pigment to match the shade of the slab including rubbing
and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :

25 mm thick. sqm
2 local stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm sqm
(average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement
slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing
complete.

Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the
manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours,
3 shades, laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including Sqm
pointing the joints with white cement and matching pigments etc., complete.

4
Providing and laying Ceramic glazed floor tiles 600x600 mm (thickness to be specified by the
manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours,
shades, laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including Sqm
pointing the joints with white cement and matching pigments etc., complete.

X PLASTERING
1 6 mm cement plaster of mix :
1:3 (1 cement: 3 fine sand) sqm

2 15 mm cement plaster on the rough side of single or half brick wall of mix :
1:6 (1 cement: 6 fine sand) Sqm

3 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 sqm
cement: 5 coarse sand) finished with a top layer 6mm thick cement plaster 1:6 (1 cement: 6
fine sand).
4 Distempering with oil bound washable distemper of approved brand and manufacture to give an
even shade

5 New work (two or more coats) over and including priming coat with cement primer. sqm

Painting with synthetic enamel paint of approved brand and manufacture of required colour to
6
give an even shade:

Two or more coats on new work over an under coat of suitable shade with ordinary
7 Sqm
paint of approved brand and manufacture.

8 Providing & applying Plastic Emulsion paint of approved brand and shade, two or
more coats at all floor levels on new plastered surface to give an even shade
including cleaning & preparation of surface, applying putty and one coat of primer
including erection and dismantling of scaffolding, working platforms as necessary
complete to the satisfaction of Engineer.(ICI-Dulux/Asian Apcolite superacrylic or
equivalent)Nothing extra shall be payable for repairing & touch-ups till handing
over. Sqm

9 Finishing walls with textured exterior paint of required shade :


10 Walls existing & new work (Two or more coats applied @ 3.28 ltr/10 sqm) over and sqm
including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.

XI DOORS, WINDOWS & HARDWARE


Providing wood work in frames of doors, windows, clerestory windows and other frames,
1
wrought framed and fixed in position :
2 Locally available wood cum
Providing and fixing panelled or panelled and glazed shutters for doors, windows and
3 clerestory windows including ISI marked black enamelled M.S butt hinges with necessary
screws excluding, panelling which will be paid for separately.
35 mm thick shutters sqm
4 12mm thick clear toughened glass and hardware fittings
HARDWARE
5 Providing & Fixing Hardware as per approval
6 Providing and fixing locks, handles, bolts etc as per approval. each
7 Float glass of Nominal Thickness 4mm whereever required Sqm
8 Brick Ballast Filling Under Floor cum

XII INTERNAL WALLS


1
Providing & fixing G.I. (India Gypsum make) frame work for partitions with verticle members at
600mm C/C formed out of 37.5mm X 50mm thick G.I sections of Gypsum India make with
horizontal member at the floor & soffit and . The partitions to have horizontal nogging channels
at every 600mm c/c. complete as per detail dwg. & manufacturers specification.
Contractor to make provision for fixing all electrical, networking boxes formed out of 12mm thick
ply boxing screwed onto partition framework at required heights/levels as directed.
Partition walls in 4.5" thickness
Partition walls in 9" thickness
2 Glazed partition : Providing and fixing of 12 mm thk clear toughened glass of approved make.
The glazing shall be fixed with all necessary hardware including SS 'U' Channels to receive
glass on floor. Hardware of Dorma make or euivallent.
3 P/F lacquered glass, white blinded as per design
4 Half Opaque Half Glazed Partition : lower, as mentioned above in Opaque partition item and
upper , as mentioned above in Glazed partition item
5 Opaque walls finished in Pure White Emulsion Paint (Asian paint or Equivalent) matching
RAL9010
6 Film on Glass Partitions (as/internal elevation & spec.)
7 Providing & applying red-oxide, zinc oxide & primer coating on steel structure & cable trays in
sqm
office building & warehouse
8 Providing & applying Powder coating on steel structure & cable trays in office building &
sqm
warehouse

XII EXTERNAL WALLS


1 External Walls- Exterior emulsion paint(Asian or equivalent)
2 Exterior Glazing (Saint Gobain or equivalent) in Service reception area fixed directly in floor and
ceiling in powder coated Alumnium "U" channel.
3 Corrugated sheet (as approved) in sinus pattern painted with grey Lacqured paint (Asian or
Equivalent) on Exterior side.
4 Translucent acrylic sheet (as approved) as 3' wide inserts
XIII CEILING
Providing and fixing trap doors for access to the areas above false ceiling. The trap door shall
have an external frame made of 50mm x 50 mm. Shutter shall be made of 19mm thk
1
commercial board and finished with 1.0mm thick laminate externally and enamel paint internally.
(if ductable units)
2 Providing & fixing GI framing for suspended false ceiling as per engineers instructions
3 Providing & fixing POP ceiling and finishing as per approved emulsion paint finish.
4 Providing and fixing Suspended False Ceiling which includes Gypsum Plaster board 12mm thk.

Boards to be joint & finished so as to have flush look including filling finishing edges with jointing
5
compound paper tape/cloth gauze & 2 coats of primer suitable for plaster board.
Rate to include M.S.framing around A/C ducts where ever necessary.
Rate to include cove profile, cut-outs for light fixtures, spot lights, smoke detectors, Pelmets,
Vertical risers as shown in dwg. and all services cut outs as required. complete as directed by
Project manager / Architect.

XV WOOD WORK
1 P/Foverhead storage/ full ht. storage/open cabinet in 19mm commercial board (with 10mm MDF
if req.) (Approximate depth of 450 mm)
2 Outer face finished in Lacquered paint of approved colour.
3 Outer face finished in laminate of approved colour.
4 Inside of storage to be in laminate of approved colour.

XVI SITE
1 Green wall installations
2 Cobbled stone procurement & laying after preparing base. Patterns as per design.
3 Solar panels installation
4 Turbo vents with translucent acrylic sheet installation
5 Interior & industrial lights installation

XVII Internal water supply & sanitary installations(@4%)


XVIII Contingencies (@3%)
GRAND TOTAL