SN54/74LS76A

DUAL JK FLIP-FLOP
WITH SET AND CLEAR
The SN54/ 74LS76A offers individual J, K, Clock Pulse, Direct Set and Di-
rect Clear inputs. These dual flip-flops are designed so that when the clock
goes HIGH, the inputs are enabled and data will be accepted. The Logic Level DUAL JK FLIP-FLOP
of the J and K inputs will perform according to the Truth Table as long as mini- WITH SET AND CLEAR
mum set-up times are observed. Input data is transferred to the outputs on the
HIGH-to-LOW clock transitions. LOW POWER SCHOTTKY

J SUFFIX
MODE SELECT TRUTH TABLE CERAMIC
CASE 620-09
INPUTS OUTPUTS 16
OPERATING MODE 1
SD CD J K Q Q
Set L H X X H L
Reset (Clear) H L X X L H
*Undetermined L L X X H H
N SUFFIX
Toggle H H h h q q
PLASTIC
Load 0 (Reset) H H l h L H
16 CASE 648-08
Load 1 (Set) H H h l H L
Hold H H l l q q 1
*Both outputs will be HIGH while both SD and CD are LOW, but the output states are unpredictable
if SD and CD go HIGH simultaneously.
H,h = HIGH Voltage Level D SUFFIX
L,l = LOW Voltage Level
SOIC
X = Immaterial 16
1 CASE 751B-03
l, h (q) = Lower case letters indicate the state of the referenced input (or output) one setup time prior
to the HIGH-to-LOW clock transition

ORDERING INFORMATION
SN54LSXXJ Ceramic
SN74LSXXN Plastic
SN74LSXXD SOIC
LOGIC DIAGRAM

LOGIC SYMBOL

Q 2 7
Q
SD 15 SD 11
16 K Q 12 K Q

1 CP 6 CP
CLEAR (CD) SET (SD)
K 4 J C Q 14 9 J C Q 10
J D D

3 8
CLOCK (CP) VCC = PIN 5
GND = PIN 13

FAST AND LS TTL DATA


5-79
SN54/74LS76A

GUARANTEED OPERATING RANGES


Symbol Parameter Min Typ Max Unit
VCC Supply Voltage 54 4.5 5.0 5.5 V
74 4.75 5.0 5.25
TA Operating Ambient Temperature Range 54 55 25 125 C
74 0 25 70
IOH Output Current High 54, 74 0.4 mA
IOL Output Current Low 54 4.0 mA
74 8.0

DC CHARACTERISTICS OVER OPERATING TEMPERATURE RANGE (unless otherwise specified)


Limits
Symbol Parameter Min Typ Max Unit Test Conditions
Guaranteed Input HIGH Voltage for
VIH Input HIGH Voltage 2.0 V
All Inputs
54 0.7 Guaranteed Input LOW Voltage for
VIL Input LOW Voltage V
74 0.8 All Inputs

VIK Input Clamp Diode Voltage 0.65 1.5 V VCC = MIN, IIN = 18 mA
54 2.5 3.5 V VCC = MIN, IOH = MAX, VIN = VIH
VOH Output HIGH Voltage
74 2.7 3.5 V or VIL per Truth Table

54, 74 0.25 0.4 V IOL = 4.0 mA VCC = VCC MIN,


VOL Output LOW Voltage VIN = VIL or VIH
74 0.35 0.5 V IOL = 8.0 mA per Truth Table

J, K 20
Clear 60 A VCC = MAX, VIN = 2.7 V
Clock 80
IIH Input HIGH Current
J, K 0.1
Clear 0.3 mA VCC = MAX, VIN = 7.0 V
Clock 0.4
J, K 0.4
IIL Input LOW Current mA VCC = MAX, VIN = 0.4 V
Clear, Clock 0.8
IOS Short Circuit Current (Note 1) 20 100 mA VCC = MAX
ICC Power Supply Current 6.0 mA VCC = MAX
Note 1: Not more than one output should be shorted at a time, nor for more than 1 second.

AC CHARACTERISTICS (TA = 25C, VCC = 5.0 V)


Limits
Symbol Parameter Min Typ Max Unit Test Conditions
fMAX Maximum Clock Frequency 30 45 MHz
VCC = 5.0 V
tPLH 15 20 ns
Clock, Clear, Set to Output CL = 15 pF
tPHL 15 20 ns

AC SETUP REQUIREMENTS (TA = 25C)


Limits
Symbol Parameter Min Typ Max Unit Test Conditions
tW Clock Pulse Width High 20 ns
tW Clear Set Pulse Width 25 ns
VCC = 5.0 V
ts Setup Time 20 ns
th Hold Time 0 ns

FAST AND LS TTL DATA


5-80
This datasheet has been download from:

www.datasheetcatalog.com

Datasheets for electronics components.