Вы находитесь на странице: 1из 3

Table B.2.

2 Utility Summary for Unit 300

bfw to bfw to Bfw to bfw to cw to


Stream Name
E-301 E-302 E-303 E-304 E-305

Flowrate (kg/h) 851 1,121 4,341 5,424 118,300

Ips to cw to hps to cw to
Stream Name
E-306 tE-307 E-308* E-309
Flowrate (kg/h)
4,362 174,100 3,124 125,900

Table B.2.3 Major Equipment Summary for Unit 300

Heat Exchangers
E-301 E-305
A = 62.6 m A = 348 m
1-2 exchanger, floating head, stainless steel 1-2 exchanger, floating head, carbon steel
Process stream in tubes Process stream in shell
Q = 1,967 MJ/h Q = 4,943 MJ/h
Maximum pressure rating of 2,200 kPa Maximum pressure rating of 2,200 kPa
E-302 E-306
A = 80.1 m A = 57.8 m
1-2 exchanger, floating head, stainless steel 1-2 exchanger, fixed head, carbon steel
Process stream in tubes Process stream in shell
Q = 2,592 MJ/h Q = 9,109 MJ/h
Maximum pressure rating of 2,200 kPa Maximum pressure rating of 2,200 kPa
E-303 E-307
A = 546 m A = 54.6 m
1-2 exchanger, floating head, stainless steel 1-2 exchanger, floating head, carbon steel
Process stream in tubes Process sheam in shell
Q = 10,080 MJ/h Q = 7,276 MJ/h
Maximum pressure rating of. 2,200 kPa Maximum pressure rating of 200 kPa
E-304 E-308
A = 1,567 m A = 22.6 m
1.-2 exchanger, fixed head, carbon steel 1-2 exchanger, fixed head, carbon steel
Process stream in tubes Process stream in shell
Q = 12,367 MJ/h Q = 5,281 MJ/h
Maximum pressure rating of 2,200 kPa Maximum pressure rating of 200 kPa
(continued)
Table B.2.3 Major Equipment Summary for Unit 300 (Continued)

Heat Exchangers (Continued)


E-309
A = 17.5 m
1-2 exchanger, floating head, carbon steel
Process stream in shell
Q = 5,262 MJ/h
Maximum pressure rating of 200 kPa
Fired Heater
H-301
Required heat load = 22,376 MJ/h
Design (maximum) heat load = 35,000 MJ/h
Tubes = Stainless steel
75% thermal efficiency
Maximum pressure rating of 2,200 kPa
Pumps
P-301A/B P-304 A/B
Positive displacement/electric drive Centrifugall electric drive
Carbon steel Carbon steel
Actual power = 15 kW Actual power = 1.4 kW
Efficiency 75% Efficiency 80%
P-302 A/B P-305 A/B
Centrifugal/electric drive Positive displacement/electric drive
Carbon steel Carbon steel
Actual power = 1 kW Actual power = 2.7 kW
Efficiency 75% Efficiency 75%
P-303 A/B
Centrifugal/electric drive
Carbon steel
Actual power= 1 kW
Efficienry 75%
Reactors
R-301 R-303
316 stainless steel packed bed, ZSM-S 316 stainless steel packed bed, ZSM-5
molecular sieve catalyst molecular sieve catalyst
V= 20 m3 V=30 m
11 m long, 7.72 m diameter 12 m long, 1.97 m diameter
Maximum pressure rating of 2,200 kPa Maximum pressure rati4 g of. 2,200 kPa
Maximum allowable catalyst temperature Maximum allowable catalyst temperature
= 500C = 500C
R-302 R-304
316 stainless steel packed bed, ZSM-S 316 stainless steel packed bed, ZSM-5
molecular sieve catalyst molecular sieve catalyst
V = 25 m V = 1.67 m
12 m long, 1.85 m diameter 5 m long, 0.95 m diameter
Maximum pressure rating of 2,200 kPa Maximum pressure rating of 2,200 kPa
Maximum allowable catalyst temperatue Maximum allowable catalyst temperature
= 500C = 525"C
(continued)
Table B.2.3 Major Equipment Summary for Unit 300 (Continued)

Towers
T-301 T-302
Carbon steel Carbon steel
45 SS sieve trays plus reboiler and total 76 SS sieve trays plus reboiler and total
condenser condenser
42% efficient trays 45% efficient trays
Feed on tray 19 Feed on hay 56
Additional feed ports on trays 14 and 24 Additional feed ports on trays 50 and 62
Reflux ratio = 0.3874 Reflux ratio = 0.6608
24-in tray spacing 15-in tray spacing
Column height = 27.45 m Column height= 28.96 m
Diameter = 1.7 m Diameter = 1.5 m
Maximum pressure rating of 300 kPa Maximum pressure rating of 300 kPa
Vessels
V-301 V-303
Carbon steel Carbon steel
Horizontal Horizontal
L/D = 5 L/D = 3
V = 7 m V = 7.7 m
Maximum operating pressure = 250 kPa Maximum operating pressure = 300 kPa
v-302 V-304
Carbon steel with SS demister Carbon steel
Vertical Horizontal
L/D=3 L/D = 3
V = 10 m V = 6.2 m
Maximum operating pressure = 250 kPa Maximum operating pressure = 300 kPa