Designation: E2533 09

Standard Guide for


Nondestructive Testing of Polymer Matrix Composites Used
in Aerospace Applications1
This standard is issued under the fixed designation E2533; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon () indicates an editorial change since the last revision or reapproval.

1. Scope The composites of interest are primarily, but not exclusively


1.1 This guide provides information to help engineers select limited to those containing high modulus (greater than 20 GPa
appropriate nondestructive testing (NDT) methods to charac- (33106 psi)) fibers. Furthermore, an emphasis is placed on
terize aerospace polymer matrix composites (PMCs). This composites with continuous (versus discontinuous) fiber rein-
guide does not intend to describe every inspection technology. forcement.
Rather, emphasis is placed on established NDT methods that 1.7 This guide is applicable to polymeric matrix composites
have been developed into consensus standards and that are containing but not limited to bismaleimide, epoxy, phenolic,
currently used by industry. Specific practices and test methods poly(amide imide), polybenzimidazole, polyester (thermoset-
are not described in detail, but are referenced. The referenced ting and thermoplastic), poly(ether ether ketone), poly(ether
NDT practices and test methods have demonstrated utility in imide), polyimide (thermosetting and thermoplastic),
quality assurance of PMCs during process design and optimi- poly(phenylene sulfide), or polysulfone matrices; and alumina,
zation, process control, after manufacture inspection, in- aramid, boron, carbon, glass, quartz, or silicon carbide fibers.
service inspection, and health monitoring. 1.8 The composite materials considered herein include
1.2 This guide does not specify accept-reject criteria and is uniaxial laminae, cross-ply laminates, angle-ply laminates, and
not intended to be used as a means for approving composite structural sandwich constructions. The composite components
materials or components for service. made therefrom include filament-wound pressure vessels,
1.3 This guide covers the following established NDT meth- flight control surfaces, and various structural composites.
ods as applied to polymeric matrix composites: Acoustic 1.9 The values stated in SI units are to be regarded as the
Emission, Computed Tomography, Leak Testing, Radiography, standard. The values given in parentheses are provided for
Radioscopy, Shearography, Strain Measurement (contact meth- information only.
ods), Thermography, Ultrasound, and Visual NDT. 1.10 This standard does not purport to address all of the
1.4 The value of this guide consists of the narrative descrip- safety concerns, if any, associated with its use. It is the
tions of general procedures and significance and use sections responsibility of the user of this standard to establish appro-
for established NDT methods as applied to polymer matrix priate safety and health practices and determine the applica-
composites. Additional information is provided about the use bility of regulatory limitations prior to use.
of currently active standard documents (an emphasis is placed 2. Referenced Documents
on applicable standard guides, practices, and test methods of
ASTM Committee E07 on Nondestructive Testing), geometry 2.1 ASTM Standards:2
and size considerations, safety and hazards considerations, and C274 Terminology of Structural Sandwich Constructions
information about physical reference standards. D3878 Terminology for Composite Materials
1.5 To ensure proper use of the referenced standard docu- E543 Specification for Agencies Performing Nondestruc-
ments, there are recognized NDT specialists that are certified in tive Testing
accordance with industry and company NDT specifications. It E1316 Terminology for Nondestructive Examinations
is recommended that a NDT specialist be a part of any 2.2 ASNT Standard:
composite component design, quality assurance, in-service SNT-TC-1A Recommended Practice for Personnel Qualifi-
maintenance or damage examination. cation and Certification in Nondestructive Testing3
1.6 This guide summarizes the application of NDT methods
to fiber- and fabric-reinforced polymeric matrix composites.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
1
This guide is under the jurisdiction of ASTM Committee E07 on Nondestruc- contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
tive Testing and is the direct responsibility of Subcommittee E07.10 on Specialized Standards volume information, refer to the standards Document Summary page on
NDT Methods. the ASTM website.
3
Current edition approved May 15, 2009. Published July 2009. DOI: 10.1520/ Available from American Society for Nondestructive Testing, P. O. Box 28518,
E2533-09. 1711 Arlington Lane, Columbus, OH 43228-0518.

Copyright. ASTM International, 100 Barr Harbour Drive, PO box C700 West Conshohocken, Pennsylvania 19428-2959, United States

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
1
Downloaded/printed by
E2533 09
2.3 ASTM Adjuncts: 3.3.11 structural sandwich constructionsee Terminology
Curing Press Straining block (13 Drawings)4 C274.
3. Terminology
4. Summary of Guide
3.1 AbbreviationsThe following abbreviations are
4.1 This guide describes and provides references for the
adopted in this guide: Acoustic Emission (AE), Computed
practice and utilization of the following established NDT
Radiography (CR), Computed Tomography (CT), Digital Ra-
methods as applied to polymeric matrix composites:
diology (DR), Leak Testing (LT), Radiography (RT), Radios-
4.1.1 Acoustic Emission (Section 7).
copy (RTR), and Ultrasound (UT).
3.2 DefinitionsDefinitions of terms related to NDT of 4.1.2 Computed Tomography (X-ray Method) (Section 8).
aerospace composites which appear in Terminology E1316 and 4.1.3 Leak Testing (Section 9).
Terminology D3676 shall apply to the terms used in the guide. 4.1.4 Radiography, Computed Radiography (CR), Digital
3.3 Definitions of Terms Specific to This Standard: Radiology (DR) with Digital Detector Array (DDA) Systems,
3.3.1 aerospaceany component that will be installed on a and Radioscopy (Section 10)
system that flies. 4.1.5 Shearography (Section 11).
3.3.2 cognizant engineering organizationthe company, 4.1.6 Strain Measurement (Strain Gauges) (Section 12).
government agency, or other authority responsible for the 4.1.7 Infrared Thermography (Non-Contact Methods Using
design, or end use, of the system or component for which NDT Infrared Camera) (Section 13).
is required. This, in addition to the design personnel, may 4.1.8 Ultrasound (Section 14).
include personnel from engineering, materials and process 4.1.9 Visual NDT (Section 15).
engineering, stress analysis, NDT, or quality groups and other, 4.2 NDT Method SelectionComposite components such
as appropriate. as laminates, moldings, and subassemblies may be inspected
3.3.3 composite materialsee Terminology D3878. by simple procedures consisting of dimensional and tolerance
3.3.4 composite componenta finished part containing measurements, weight and density determinations, cure deter-
composite material(s) that is in its end use application configu- minations by hardness measurements, visual examination for
ration, and which has undergone processing, fabrication, and defects, and tapping for void determinations. If the integrity of
assembly to the extent specified by the drawing, purchase the subassembly warrants a more complete inspection, this can
order, or contract. be accomplished by using various NDT methods. Nondestruc-
3.3.5 composite shella multilayer filament-winding that tive tests can usually be made rapidly. However, nondestructive
comprises a second shell that reinforces the inner shell. The testing will, in general, add to component cost and should be
composite shell consists of continuous fibers, impregnated with used only when warranted on critical applications. Also, the
a matrix material, wound around the inner shell, and cured in extent of NDT on composite parts depends on whether the part
place. The number of layers, fiber orientation, and composite is a primary structure safety of flight, or secondary structure
shell thickness may vary from point-to-point. non-safety of flight. The type or class of part is usually defined
3.3.6 disbondsee Terminology D3878. on the engineering drawing. Some of the defects that can be
3.3.7 filament wound pressure vesselan inner shell over- detected by NDT are given in Table 1.
wrapped with composite layers that form a composite shell. 4.3 General Facility and Personnel Qualification
The inner shell or liner may consist of an impervious metallic Minimum general requirements for NDT facilities and person-
or nonmetallic material. The vessel may be cylindrical or nel qualification are given in Practice E543. This practice can
spherical and will have at least one penetration with valve be used as a basis to evaluate testing or inspection agencies, or
attachments for introducing and holding pressurized liquids or both, and is intended for use for the qualifying or accrediting,
gases. or both, of testing or inspection agencies, public or private.
3.3.8 in-servicerefers to composite components that have Method specific considerations are discussed in the appropriate
completed initial fabrication and are in use (or in storage) for section (Sections 7 to 15).
their intended function. 4.4 General Equipment and Instrumentation
3.3.9 microcrackinvisible cracks (< 50 to 100 m size) ConsiderationsGeneral equipment and instrumentations
that are precursors to visible cracks. In angle-ply continuous considerations are provided in Practice E543. NDT method
fiber-reinforced composites, for example, microcracks form specific considerations are discussed in the appropriate section
preferentially under tensile loading in the matrix in off-axis (Sections 7 to 15).
plies. Since most microcracks do not penetrate the reinforcing 4.5 Reference StandardsPhysical reference standards
fibers, microcracks in a cross-plied tape laminate or in a simulating target imperfections or discontinuities are used to
laminate made from cloth prepreg are usually limited to the validate NDT results. The use of physical reference standards
thickness of a single ply. also helps to ensure reproducibility and repeatability of mea-
3.3.10 reference standardsobjects that provide a known, surements. Certified physical reference standards calibrated by
reproducible and repeatable response to a specific stimulus. accepted government or industrial agencies may be used.
May be in the form of hardware or software. 4.6 Extent of ExaminationSpecific applications may re-
quire local regions or the entire component to be examined.
4
Available from ASTM International Headquarters. Order Adjunct No. Examination may be real time or delayed based upon the
ADJF1364. availability of data. Examination may be direct, or indirect, on

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
2
Downloaded/printed by
E2533 09
TABLE 1 Defects Detected By NDT Methods
Radiology
Acoustic Computed Leak with DDA; Strain Visual
Defect Shearography Thermography Ultrasound
Emission Tomagraphy Testing Radiography, Measurment NDT
CR, Radioscopy
Contamination X X X X
Damaged Filaments X X X
Delamination X X X X X X
Density Variation X X X X
Deformation under Load X X
Disbond X X X X X
Fiber Debonding X XA X X
Fiber Misalignment X X X
Fractures X X X X X X
Inclusions X X X X X
Leaks X X X
Loose or Moving Parts X
B
Microcracks X X XB,C X X
Moisture X XD,E X
Porosity X X X X X
Thickness Variation X XF X X X
Undercure X
Volumetric Effects X
Voids X X X X X X
A
Can detect after impact (voids).
B
Depends on opening/size of crack.
C
Depends on angle of beam relative to planar defect and opening.
D
Only in central projection (Radiography, CR).
E
Radioscopic mode (Radiology with DDA).
F
For Radiography, applicable to CR and digitized films only.

site or remote as specified in the contractual agreement or 5.2 Certain Practices referenced in the guide are written so
established requirements documents. they can be specified on the engineering drawing, specification,
4.7 Timing of ExaminationExaminations shall be per- purchase order, or contract, for example, Practice E1742
formed in accordance with the contractual agreement or (Radiography).
established requirements documents, and may be performed 5.3 Acceptance CriteriaDetermination about whether a
during the life cycle of the article under test. composite material or component meets acceptance criteria and
4.8 Type of ExaminationsMany different NDT system is suitable for aerospace service must be made by the cognizant
configurations are possible due to the wide range of system
engineering organization. When examinations are performed in
components available. It is important for the purchaser of NDT
accordance with the referenced documents in this guide, the
to understand the capability and limitations of the applicable
engineering drawing, specification, purchase order, or contract
configuration. Selection of the NDT Method and system shall
be at the discretion of the testing agency unless specified by the shall indicate the acceptance criteria.
purchaser in a contract or requirements document (that is, 5.3.1 Accept/reject criteria shall consist of a listing of the
engineering drawing, specifications, etc.). expected kinds of imperfections and the rejection level for
4.8.1 Many different NDT system configurations are pos- each.
sible due to the wide range of system components available. It 5.3.2 The classification of the articles under test into zones
is important for the purchaser of NDT to understand the for various accept/reject criteria shall be determined from
capability and limitations of the applicable configuration. contractual documents.
4.9 A tabular comparison of most of the established NDT 5.3.3 Rejection of Composite ArticlesIf the type, size, or
methods discussed in the guide is given in Appendix X1 of quantities of defects are found to be outside the allowable
Practice E543; namely, acoustic emission, leak testing, radiog- limits specified by the drawing, purchase order, or contract, the
raphy, strain measurement, thermography (infrared), and ultra-
composite article shall be separated from acceptable articles,
sound are covered. The comparison summarizes properties
appropriately identified as discrepant, and submitted for mate-
sensed or measured, typical discontinuities detected, represen-
rial review by the cognizant engineering organization, and
tative application, applicable ASTM standards, and advantages
dispositioned as (1) acceptable as is, (2) subject to further
and limitations. A similar overview is provided below (Table
2). rework or repair to make the materials or component accept-
able, or (3) scrapped when required by contractual documents.
5. Significance and Use 5.3.4 Acceptance criteria and interpretation of result shall
5.1 This guide references requirements that are intended to be defined in requirements documents prior to performing the
control the quality of NDT data. The purpose of this guide, examination. Advance agreement should be reached between
therefore, is not to establish acceptance criteria and therefore the purchaser and supplier regarding the interpretation of the
approve composite materials or components for aerospace results of the examinations. All discontinuities having signals
service. that exceed the rejection level as defined by the process

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
3
Downloaded/printed by
E2533 09
TABLE 2 General Overview of Established NDT Methods

What Is Seen
NDT Method Applications Advantages Limitations Other Considerations
and Reported?
Acoustic Emission Global monitoring of Remote and continuous The part being inspected The AE technique Inspection tests and
composite structures to monitoring on an entire must be stressed by an records transient elastic results are unique to
detect and locate active composite article in real external stimulus. With waves produced by each application and
sources in real time. time is possible. Can the exception of certain applied stress or should be conducted
also detect growth of imperfections or resulting stress with expert oversight.
active imperfections or discontinuities that AE relaxation of the
discontinuities, and to detects by friction- composite material or
detect and determine the generated AE (for component. The
location of discontinuities example, delamination mechanical waves are
and defects that may be surfaces rubbing), AE- produced as either burst
inaccessible by other inactive (non- or continuous AE. AE
NDT methods. propagating) activity, intensity and
imperfections or severity correlated with
discontinuities cannot be applied stress yield
detected and structurally information on the
insignificant degradation within the
imperfections or article under test.
discontinuities may
produce AE. Therefore,
the significance of a
detected AE source
cannot be assessed
unambiguously.

Computed Tomography Detects sub-surface Produces clear cross- Requires access to all A digitized cross- Tooling and/or part-
volumetric imperfections sectional image slices of sides of the article under sectional CT-density map handling fixtures may be
or discontinuities. an object. Obtain 3D test. Not very applicable (tomogram) of the article required.
Provides quantitative, imperfection or to the inspection of large under test. Allows full,
volumetric analysis of discontinuity data. areas, or objects with three dimensional CT-
imperfections or Extensive image high (>15) aspect ratios. density maps to be
discontinuities detectable processing capability. obtained for sufficiently
by other NDT methods. small composite parts.
Also suitable for
measuring geometric
characteristics.

Leak Testing Any composite material Less ambiguous than Test equipment costs Qualitative indications, Different techniques are
or component across liquid penetrant testing; increase as the required for example bubbles, or available for
which a differential more sensitive than AE leak test sensitivity quantitative characterization of large
pressure exists and or UT. increases. measurements, for leaks (with rates as high
where through-leakage example, detector as 10-2 Pa m3 s-1 (10-1
or in-leakage of product, deflections, that std cm3 s-1)) and small
air, water vapor, or other ascertain the presence leaks (rates less then
contaminant over the or location, or 10-5 Pa m3 s-1 (10-4 std
projected service life are concentration or leak cm3 s-1)).
of concern. rate of a leaking fluid.

Radiography, Primarily detects sub- Film and some imaging Requires access to both Projected area and Part may need to be
Computed Radiology, surface imperfections or plates can be cut and sides of the article under density variation of moved to an X-ray lab;
Radiology with Digital discontinuities such as placed almost anywhere test. Accessibility may subsurface imperfections Film RT requires film
Detector Arrays, porosity & inclusions. on the part. Digital need to be evaluated. or discontinuities. storage and disposal of
Radioscopy Planar imperfections or images can be Unable to determine chemicals which can be
discontinuities are processed for additional depth of imperfections or expensive. Digital
detected if the beam is information and discontinuities; techniques (CR, DDA)
directed along the automated defect sometimes possible from are usually faster.
imperfection or recognition. In digital images after Radiation safety. In
discontinuity and the radioscopy, techniques calibration or with radioscopy, radiation
unsharpness is less than using an image additional X-ray safety more problematic
the imperfection or intensifier and DDA can exposures from different if a moving source is
discontinuity opening/ be automated by directions. used, versus movement
size. interfacing with a robot of part.
or part manipulator thus
allowing the potential for
a faster inspection

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
4
Downloaded/printed by
E2533 09

TABLE 2 Continued
What Is Seen
NDT Method Applications Advantages Limitations Other Considerations
and Reported?
Shearography Detects subsurface Well suited for high Subsurface imperfection An interference pattern Additional equipment is
imperfections or speed, automated or discontinuity must be created by subtracting or required to determine
discontinuities or inspection in production sufficiently large to superimposing images of surface derivative slope
changes in modulus or environments. cause measurable the article under test changes, and thus use
out-of-plane deformation. surface disdeformation taken before and after the method as a
under load. Surface loading, thus revealing quantitative tool.
condition, especially localized strain
glossiness, can interfere concentrations.
with accurate
shearographic detection,
thus requiring the use of
surface dulling agents
(exception: thermal
shearography).

Strain Measurement Can be used to measure Relatively inexpensive, Individual strain gauges The output of a Depending on desired
static and dynamic and less bulky and better cannot be calibrated and resistance measuring sensitivity, resistance to
tensile and compressive resolution than are susceptible to circuit is expressed in drift, insensitivity to
strain, as well as extensometers (can unwanted noise and millivolts output per volt temperature variations,
shearing, Poisson, achieve an overall other sources of error input. or stability of installation,
bending, and torsional accuracy of better than such as expansion or a variety of strain
strains. 6 0.10% strain). contraction of the strain- gauges are available (for
gauge element, change example, semiconductor
in the resistivity, and wafer sensors, metallic
hysteresis and creep bonded strain gauges,
caused by imperfect thin-film and diffused
bonding. semiconductor strain
gauges).

Thermography Detects disbonds, Quick observation of Composites have The aerial temperature Both contact (requires
delaminations, voids, large surfaces and temperature limits distribution is measured application of a coating)
pits, cracks, inclusions, identification of regions beyond which by mapping contours of and noncontact methods
and occlusions, that should be examined irreversible matrix and equal temperature (relies on detection of
especially in thin articles more carefully. fiber damage can occur. (isotherms), thus yielding infrared blackbody
under test having low Imperfection or a heat emission pattern radiation) are available.
thermal conductivity, low discontinuity detection related to surface and Thermography is either
reflectivity/high emissivity depends on orientation subsurface defects. passive or active, active
surfaces, and in of an imperfection or thermography can be
materials which dissipate discontinuity relative to further subdivided into
energy efficiently, the direction of heat flow. pulse or lock-in
In thicker materials, only techniques.
qualitative indications of
imperfections or
discontinuities are
possible.

Ultrasound Detects sub-surface Detects sub-surface Requires a relatively flat Imperfections or Possible fluid
imperfections or imperfections or and smooth surface. discontinuities are entrapment; Possible
discontinuities. There are discontinuities including Material type can affect directly recorded on fluid absorption into
two primary techniques; porosity, inclusions, & inspectability. amplitude images. porous materials such as
pulse echo for one sided delaminations. composites. Numerous
inspections and through techniques available
transmission for two including longitudinal,
sided inspections. shear or surface waves.
Attenuation can be
comparatively high in
PMCs compared to
metallic articles.

Visual NDT Detects disruptions on Low cost. Detect surface Requires direct line of Imperfections or Can find imperfections or
surfaces being viewed. imperfections or sight. discontinuities are discontinuities on inside
discontinuities including directly recorded on diameters if a central
delaminations, fiber inspection conductor can be
breakage, impact documentation inserted and satisfactory
damage. sometimes photographs. electrical contact made.

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
5
Downloaded/printed by
E2533 09
requirements documents shall be rejected unless it is deter- specification change, specification revision and date, software
mined from the part drawing that the rejectable discontinuities and hardware considerations will also govern how reporting is
will not remain in the finished part. performed.
5.4 Life Cycle ConsiderationsThe referenced NDT prac-
tices and test methods have demonstrated utility in quality 6. Procedure
assurance of PMCs during the life cycle of the product. The 6.1 When NDT produces an indication of a material discon-
modern NDT paradigm that has evolved and matured over the tinuity, the indication is subject to interpretation as false,
last twenty years has been fully demonstrated to provide nonrelevant, or relevant (Fig. 1). If the indication has been
benefits from the application of NDT during: (a) product and interpreted as relevant, the necessary subsequent evaluation
process design and optimization, (b) on-line process control, will result in the decision to accept or reject the composite
(c) after manufacture inspection, (d) in-service inspection, (e) material or component.
and health monitoring.
5.4.1 In-process NDT can be used for feedback process 7. Acoustic Emission
control since all tests are based upon measurements which do
not damage the article under test. 7.1 Referenced Documents
5.4.2 The applicability of NDT methods to evaluate PMC 7.1.1 ASTM Standards:2
materials and components during their life cycle is summarized E569 Practice for Acoustic Emission Monitoring of Struc-
in Tables 3 and 4. tures during Controlled Simulation
5.5 General Geometry and Size ConsiderationsPart con- E650 Guide for Mounting Piezoelectric Acoustic Emission
tour, curvature, and surface condition may limit the ability of Sensors
certain tests to detect imperfections with the desired accuracy. E750 Practice for Characterizing Acoustic Emission Instru-
5.6 ReportingReports and records shall be specified by mentation
agreement between purchaser and supplier. It is recommended E976 Guide for Determining the Reproducibility of Acous-
that any NDT report or archival record contain information, tic Emission Sensor Response
when available, about the material type, method of fabrication, E1067 Practice for Acoustic Emission Examination of Fi-
manufacturers name, part number, lot, date of lay-up and/or of berglass Reinforced Plastic Resin (FRP) Tanks/Vessels
cure, date and pressure load of previous tests (for pressure E1118 Practice for Acoustic Emission Examination of Re-
vessels), and previous service history (for in-service and failed inforced Thermosetting Resin Pipe (RTRP)
composite articles). Forwards and backwards compatibility of E1211 Practice for Leak Detection and Location Using
data, data availability, criticality (length of data retention), Surface-Mounted Acoustic Emission Sensors

TABLE 3 Application Examples of Established NDT Methods During Life Cycle


NDT Method Application
Acoustic Emission May be used for quality control of production and fabrication processes (for example, to evaluate adhesive
bonding after lay-up winding or curing), for proof-testing of pressure vessels after fabrication, and for periodic in-
service and health monitoring inspections prior to failure.

Computed Tomography May be used as a post-fabrication metrological method to verify engineering tolerances.

Leak Testing May be used to validate leak tightness following fabrication, and in-service re-qualification of pressure vessels. For
example, helium leak detection can be used during composite article fabrication to detect and seal leaks
permanently (preferable) or temporarily in such a manner to allow repair at a later time. Similarly, halogen gas leak
detection has been used in production examination.

Radiography and Radioscopy May be used during fabrication inspection to evaluate honeycomb core imperfections or discontinuities such as
node bonds, core-to-core splices, core-to-structure splices, porosity, included material as well as verification of
structural placement. Water included material bonded structure not for laminates.

Shearography May be used in quality assurance, material optimization, and manufacturing process control.

Strain Measurement May be used during proof testing before placement into service, or during periodic re-qualification. Can be
destructive depending on the strain thresholds reached during test.

Thermography May be used to follow imperfection or discontinuity growth during service. If video thermographic equipment is
used, systems that are being dynamically tested or used can be examined in real-time.

Ultrasound Automatic recording systems allow parts to be removed from a processing line when defect severity exceeds
established limits. Measurement of the apparent attenuation in composite materials is useful in applications such
as comparison of crystallinity and fiber loading in different lots, or the assessment of environmental degradation.
Most common method applied for laminar oriented defect detection such as impact damage causing delamination
fiber fracturing, included material, and porosity.

Visual NDT Used primarily for quality inspections of composite materials and components upon receipt (after fabrication and
before installation).

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
6
Downloaded/printed by
E2533 09
TABLE 4 Application of Established NDT Methods During the Life Cycle of Polymeric Matrix Composites
Product and Process On-Line Process After Manufacture In-Service Health
Defect
Design and Optimization Control Inspection Inspection Monitoring
Acoustic Emission X X X X X
Computed Tomography X
Leak Testing X X XA
Radiography and Radioscopy X X X X
Shearography X X X X
Strain Measurement X X
Thermography X X
Ultrasound X X X X X
Visual X X X X X
A
Applicable to composites used in storage and distribution of fluids and gases, for example, filament-wound pressure vessels.

FIG. 1 Consequences of Detecting a Material Discontinuity (Indication) by NDT

E1419 Test Method for Examination of Seamless, Gas- coupled to the article under test with a suitable couplant (for
Filled, Pressure Vessels Using Acoustic Emission example, grease), or by means of an epoxy cement or other
E1932 Guide for Acoustic Emission Examination of Small adhesive. The output from the sensor is amplified and filtered
Parts to eliminate unwanted frequencies. The conditioned AE signal
E2076 Test Method for Examination of Fiberglass Rein- is then digitized and segmented into discrete AE waveform
forced Plastic Fan Blades Using Acoustic Emission packets through a process threshold detection. Digital signal
E2191 Test Method for Examination of Gas-Filled processing converts the transient waveform packets into ex-
Filament-Wound Composite Pressure Vessels Using Acoustic tracted time and frequency features which describe the tran-
Emission sient waveforms shape, size and frequency content. In sophis-
7.1.2 Compressed Gas Association Standard:5 ticated approaches, these features are sometimes analyzed
Pamphlet C-6.4 Methods for Visual Inspection of AGA together using artificial intelligence, pattern recognition and/or
NGV2 Containers neural network techniques to distinguish true AE sources from
7.1.3 Military Handbooks and Standard:6 noise. When multiple sensors in an array detect the same AE
MIL-HDBK-732A Nondestructive Testing Methods of transient, location determination can be accomplished using
Composite MaterialsAcoustic Emission arrival time analysis (triangulation) techniques. When multiple
7.2 General Procedure events are located close together they form an event cluster
7.2.1 Specially designed sensors (transducers) are used to indicating continuing activity which is indicative of an active
detect transient elastic stress waves (AE) in a material pro- growing source. In addition to AE activity generated by
duced as a result of applied external stress (tension, compres- growing imperfections or discontinuities, activity can also
sion, torsion, internal pressure, or thermal). The sensors are originate from preexisting imperfections or discontinuities that
are not growing (for example, delamination surfaces rubbing
together during depressurization of a pressure vessel).
5
Available from Compressed Gas Association, 1725 Jefferson Davis Hwy., Suite 7.3 Significance and Use
1004, Arlington, VA 22202-4102.
6
Available for Standardization Documents Order Desk, Bldg 4 Section D, 700 7.3.1 AE is a term used to describe transient elastic stress
Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS. waves produced in solids as a result of the application of stress.

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
7
Downloaded/printed by
E2533 09
TABLE 5 Summary of Acoustic Emission
What Is Seen
Applications How It Works Advantages Limitations
and Reported?
Global monitoring of AE Transducers are Remote and continuous The part or article under The AE technique monitors
composite structures to coupled to the article under monitoring of the entire test must be stressed by transient elastic stress
detect and locate active test to detect transient article under test in real an external stimulus. waves generated by
sources. elastic stress waves (or time is possible. various local processes
AE) produced during Inactive (nonpropagating) that occur in a short time
Evaluation of the structural application of external Can detect growing of imperfections or period in a structure under
integrity of finished stress (mechanical, thermal active imperfections or discontinuities cannot be stress. The lack of sensed
composite components or pressure). The location discontinuities. detected and structurally AE signals can be an
such as pipes, tubes, of the source is located by insignificant imperfections indication of a composite
tanks, and pressure triangulation or area Can detect discontinuities or discontinuities may structure having structural
vessels. (zonal) location methods. and defects that may be produce AE. Therefore, the integrity. Alternatively, if
inaccessible to other NDT significance of a detected increasing AE activity is
Quality control of methods, and determine AE source cannot be detected, that can be an
production and fabrication their location. assessed unambiguously. indication of damage
processes (for example, occurring in the structure
during lay-up winding, or Can be used for proof Nonrelevant noise must be and of a potential loss of
curing). testing of new or in-service filtered out. structural integrity. The AE
composite material signal from composites
Proof-testing after components. Transducers must be often consists of both
fabrication. Also can be placed on the part or continuous AE (qualitative
used as an alternative Can be used for periodic or article under test. description of a sustained
method to periodic continuous (in situ) health signal level produced by
hydrostatic proof testing. monitoring. Usually requires other NDT rapidly occurring acoustic
methods to characterize emission events) and burst
Periodic monitoring of detected imperfections or AE (qualitative description
regions of interest or discontinuities. of discrete signals of
concern during service. varying duration that are
usually of higher amplitude
Continuous, realtime than continuous AE).
monitoring of structures
(health monitoring).

Evaluation of adhesive
bonding.

Monitoring crack growth


prior to failure.

Leak detection.

The applied stress may include mechanical forces (tension, more activity is an indication that the structure is degraded. The
compression or torsion), internal pressure, or thermal gradients source is located by triangulation or zone location methods.
(can often be accomplished by use of a hot-air gun). The 7.3.4 In fiber-reinforced composites, AE is generated by
applied stress may be short to long, random, or cyclic. The release of stored elastic energy during processes such as
applied stress may be controlled by the examiner, or may cracking of the matrix, or fracture or splitting of fibers.
already exist as part of the process. In either case the applied Irreversible viscoelastic processes such as crazing of amor-
stress is measured along with the AE activity. phous matrices or plastic (irreversible) deformation of either
7.3.2 The resulting AE stress waves are produced by the the matrix or fiber are not detectable under normal measure-
rapid release of energy within the material from a localized ment conditions with commercial AE systems.
source. The AE signal from composites often consists of both 7.3.5 Interfacial sources of AE in fiber-reinforced compos-
continuous AE (qualitative description of a sustained signal ites include debonding of the matrix from the fibers, subse-
level produced by rapidly occurring acoustic emission events) quent fiber pull-out (rubbing), and interlaminar debonding.
and burst AE (qualitative description of discrete signals of 7.3.6 AE can also be produced by other acoustic sources in
varying duration that are usually of higher amplitude than the composite not directly related to the matrix or fiber. These
continuous AE). sources include leakage of gas or liquid through a crack,
7.3.3 The AE technique records transient elastic stress orifice, seal break or other opening (for example, in composite-
waves produced by applied stress or resulting stress relaxation overwrapped pressure vessels); and by movement or loosening
of the composite material or component. The stress waves are of parts (thread failure in assembled composite piping systems,
produced as either burst or continuous AE. AE activity, for example).
intensity and severity correlated with applied stress yield 7.3.7 Most AE signals that are useful in NDT have frequen-
information on the degradation within the article under test. cies that are above the audible range. Ordinarily they are
Lack of AE activity is an indication of a sound structure, while between 20 kHz and 1 MHz, depending on application. The

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
8
Downloaded/printed by
E2533 09
rate and amplitude of acoustic emission signals are noted and 7.3.13 Advantages and ApplicationsAE is used to evalu-
correlated to structure or composite article characteristics. ate to structural integrity of composite pipes, tubes, tanks,
Lower and higher frequencies are filtered out to avoid inter- pressure vessels, and other finished composite parts. Remote
ferences from unwanted sources of noise such as machine and real time surveillance of structures is possible. Inaccessible
vibrations or electrical equipment generated noise. imperfections or discontinuities can be detected, and their
location determined. In addition to imperfection or discontinu-
NOTE 1When detecting leaks using low frequencies generally lower
than 100 kHz, it is possible for the leak to excite mechanical resonances
ity or defect detection, AE can be used to detect leaks (see
within the article under test that may enhance the acoustic signal used to Practice E1211) and as an alternative to periodic hydrostatic
detect leakage. proof testing (see Practice E1419). AE can also be used in
quality control evaluation of production processes on a
7.3.8 In addition to immediate evaluation of the emissions sampled or 100 % inspection basis, in-process examination
detected during application of the stimulus, a permanent record during a period a applied stress in a fabrication process (for
of the number and location of emitting sources and the relative example, lay-up, winding, pressing, curing, etc.) proof-testing
amount of AE detected from each source provides a basis for after fabrication, monitoring regions of interest or concern, and
comparison with sources detected during the examination and re-examination after intervals in service. AE is particularly
during subsequent stimulation. useful for measuring adhesive bond integrity, and monitoring
7.3.9 The basic functions of an AE monitoring system are to the growth of a crack in order to give a warning of impending
detect, locate, and possibly classify emission sources. Other failure. Compared to other common NDT methods, some of the
NDT methods; for example, visual, ultrasonics, and eddy advantages AE are as follows:
current should be used to further evaluate the damage detected 7.3.13.1 AE is a global monitoring technique, capable of
in an AE-located region. detecting and locating imperfections or discontinuities a dis-
NOTE 2Determining the significance of damage with respect to tance away from the sensors without the need to scan the
residual strength or remaining life in a composite sample is presently not sensors.
possible at the same level as is done with a crack in a metallic sample, for 7.3.13.2 Can perform continuous monitoring on a complete
example, where facture mechanics can be used to determine the signifi- composite article in real time.
cance of damage.
7.3.13.3 Is very sensitive to detecting the growth of active
7.3.10 Felicity RatioThe Felicity ratio is the numerical imperfections or discontinuities compared to other NDT tech-
value of the applied stress at which significant AE begins niques; however, usually requires these other methods to
divided by the applied stress during the previous cycle. The characterize these imperfections or discontinuities.
term significant AE has no quantitative definition at this time, 7.3.13.4 Can detect discontinuities and defects that may be
and is open to interpretation by the AE practitioner. However, inaccessible to other NDT methods.
Practice E1067 suggests three guidelines for determining the 7.3.13.5 Can be used for proof testing of new or in-service
onset of significant AE: composite pressure vessels.
7.3.10.1 More than 5 bursts during a 10 % increase in 7.3.14 Limitations and InterferencesSome of the disad-
applied stress. vantages AE are as follows:
7.3.10.2 More than 20 counts during a 10 % increase in 7.3.14.1 The part or article under test must be stressed.
applied stress.
7.3.14.2 With the exception of friction-generated AE (for
7.3.10.3 Increasing AE at constant applied stress. example, delamination surfaces rubbing together), AE-inactive
7.3.11 Effect of Variables on the Felicity RatioRate of (nonpropagating) imperfections or discontinuities cannot be
application and removal of stress, time at peak applied stress, detected and structurally insignificant imperfections or discon-
AE system sensitivity, time between load cycles, stress state tinuities may produce AE. Therefore, the significance of a
during loading, AE source mechanism, test environment, and detected AE source cannot be assessed unambiguously.
the applied stress relative to the ultimate strength of the article
7.3.14.3 Nonrelevant noise must be filtered out.
under test (stress ratio) can all affect the Felicity ratio.
Composite materials and components which have rate depen- 7.3.14.4 Transducers must be placed on the part or article
dent properties, such as fiber-reinforced composites with plas- under test.
tic matrices, will be affected to a greater extent. 7.4 Use of Referenced Documents
7.3.12 Kaiser EffectIf a composite material or component 7.4.1 Applications:
is loaded to a given stress level and then unloaded, usually no 7.4.1.1 Testing of Composite Pipe, Fittings, Tanks and Small
AE will be observed upon immediate reloading until the Parts:
previous load has been exceeded. This is known as the Kaiser (1) Consult Practice E1067 for AE examination of new and
effect. The Kaiser effect is said to hold when the Felicity ratio in-service fiberglass-reinforced plastic (FRP) tanks and vessels
is $ 1.0, and violated when the Felicity ratio is # 1.0. to determine structural integrity. Practice E1067 is limited to
Therefore, the Kaiser effect holds when no new AE sources are tanks and vessels with fiber loadings greater than 15 % by
operating, or when there are no reversible AE sources present weight, and that are designed to operate at an internal pressure
during subsequent load cycling. Alternatively, when the Kaiser no greater than 0.44 MPa (65 psia) above the static pressure
effect is violated, then either or both of these cases have due to the internal contents, or at vacuum service differential
occurred. pressures levels between 0 and 0.06 MPa (0 and 9 psi).

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
9
Downloaded/printed by
E2533 09
(2) Consult Practice E1118 for AE examination of new and noise level, threshold level, dynamic range, signal overload
in-service reinforced thermosetting resin pipe (RTRP) to de- point, dead time, and counter accuracy.
termine structural integrity. Practice E1118 is limited to lined 7.4.2.3 Consult Appendix X1 of Practice E750 for a discus-
and unlined pipe, fittings, joints, and piping systems up to and sion of AE electronic components or units including sensors,
including 0.6 m (24 in.) in diameter, fabricated with fiberglass preamplifiers, filters, power amplifiers, line drive amplifiers,
or carbon fiber reinforcement at fiber loadings greater than threshold and counting instrumentation, and signal cables.
15 % by weight, and is applicable to tests below pressures of Also, most modern AE systems use computers to control
35 MPa absolute (5000 psia). collection, storage, display, and data analysis. Features of
(3) Consult Guide E1932 for techniques for conducting AE computer-based system include waveform collection as well as
examination on small parts. a wide selection of measurement parameters relating to the AE
7.4.1.2 Testing of Pressure Vessels: signal.
(1) Consult CGA Pamphlet C6 for training of personnel
NOTE 6AE signals from composites are typically of high amplitude,
conducting AE on pressure vessels. so sensor sensitivity is usually not an issue except in cases where the
(2) Consult Practice E569 for guidelines for AE examina- sensors are spaced too far apart or if the threshold is set too high. The use
tion and monitoring of structures such as pressure vessels that of non-resonant wideband (versus resonant sensors) is useful in detecting
are stressed by mechanical or thermal means. signals over a range of frequencies and is relevant when wave propagation
(3) Consult Test Method E1419 for guidelines for AE theory is being used to understand the AE signal and to more accurately
examination of noncryogenic seamless pressure vessels (tubes) locate the AE source. Otherwise, both resonant or non-resonant sensors
can be used as long as they are spaced appropriately on the composite
of the type used for distribution or storage of industrial gases material or component to maintain sensitivity to AE sources distributed
at pressures greater than encountered in service, as an alterna- across the article under test. Typical AE signals generated in composites
tive to periodic hydrostatic proof examination. are of higher amplitude near the source compared to the AE generated in
(4) Consult Test Method E2076 for measurement of AE metals. In contrast to metals, the higher frequencies in the AE signal are
during simulation of bending loads. absorbed by the composite after relatively short propagation distances.
(5) Consult Test Method E2191 for guidelines for AE of Thus, often lower frequency sensors and filters are used for composites.
Due to the fact that AE sources typically occur throughout composites
new and in-service filament-wound composite pressure vessels
when they are stressed, it is not unusual for AE sources to occur in the
at pressures equal to or greater than what is encountered in composite directly below sensors. This situation can result in a signal of
service, as an alternative to Compressed Gas Association very high amplitude. Such cases are not likely in metal samples as it is
(CGA)-mandated three-year visual examination. unlikely that a sensor will be directly over a crack tip. Due to the
amplitude of the composite AE signals, in some cases it is necessary to use
NOTE 3Slow-fill pressurization must proceed at flow rates that do not
a preamplifier with only 20 dB of gain to avoid saturation of the signal.
produce background noise from flow of the pressurizing medium. During
Most commercial AE preamplifiers saturate at 10 to 20 volts peak-to-peak
proof testing of composite pressure vessels, AE energy from a particular
voltage output. For these reasons, preamplifiers with a 20 to 40 dB gain,
AE event reaching the AE sensor will vary depending on the liquid level
10 volt peak-to-peak output voltage, and an 80100 dB dynamic range are
in the vessel. Furthermore, AE wave propagation characteristics will be
common.
affected by whether the vessel has a metal or rubber liner, for example.
NOTE 4In general, fast-fill pressurization can be used if hold periods 7.4.2.4 Consult Appendix X2 of Practice E750 for an
are used. In this case, AE data are recorded only during hold periods. explanation of suggested measurements (for example, pream-
While this hold period technique may be suitable for characterization of plifier input impedance, wave shaping, gain measurements).
glass or aramid-reinforced composites, the same technique may not be
7.4.2.5 Consult Appendix X3 of Practice E750 about the
suitable for carbon and graphite-reinforced composites.
NOTE 5For composites made by certain fabrication routes (for
electrical circuit configuration for measurement of input im-
example, filament-winding), the composite surface may not be as smooth pedance.
as is normally the case. To have a relatively uniform coupling from article 7.4.2.6 Consult Appendix X4 of Practice E750 about acous-
to article, the best amount of couplant to use may have to be determined tic and electrical noise sources.
experimentally by applying different amounts and ascertaining which 7.4.2.7 Consult Appendix A1 of Practice E1067 or Appen-
amount gives the most uniform AE signal from pencil lead breaks, for dix A1 of Practice E1118 for instrumentation performance
example.
requirements for sensors, signal cable, couplant, preamplifier,
7.4.1.3 Leak TestingConsult Practice E1211 for descrip- filters, power-signal cable, main amplifier, and the main
tion of a passive method utilizing (1) surface-mounted AE processor.
sensors, or (2) sensors attached by means of acoustic 7.4.2.8 Consult Appendix A2 of Practice E1067 or Appen-
waveguides that allow detection and location of the steady state dix A1 of Practice E1118 for baseline calibration of AE
source of gas and liquid leaking out of a pressurized system. equipment, including low-amplitude threshold, high-amplitude
Application examples to illustrate the use of AE to detect leaks threshold, and count value instrument calibration.
in a relief valve, ball valve, and a transfer line are also given in 7.4.2.9 Consult Appendix A3 of Practice E1067 for sensor
Appendix X1 of Practice E1211. placement guidelines for atmospheric, atmospheric-pressure,
7.4.2 AE Equipment and Instrumentation: and atmospheric-vacuum tanks.
7.4.2.1 Consult Guide E650 for guidelines about mounting 7.4.2.10 Consult Appendix A1 of Practice E1419 for speci-
piezoelectric AE sensors. fications for AE components; namely, sensors, signal cable,
7.4.2.2 Consult Practice E750 for required tests and mea- couplant, preamplifier, power-signal cable, power supply, and
surements on AE equipment components and units, determi- signal processor used as an alternative to periodic hydrostatic
nation of instrument bandwidth, frequency response, gain, proof testing.

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
10
Downloaded/printed by
E2533 09
7.4.2.11 Consult MIL-HDBK-732A for useful applications 7.6.1.4 Pneumatic testing is extremely dangerous. Special
details on test installation and test fixturing (Section 4); safety precautions shall be taken when pneumatic testing is
couplants and waveguides (Section 5); type, location, and required; for example, safety valves, etc.
application of sensors (Section 6); cables (Section 7); pream- 7.7 Calibration and Standardization
plifiers (Section 8); secondary amplifiers and filters (Section 9); 7.7.1 Periodic calibration and verification of pressure trans-
time domains of burst and continuous AE (Section 10); AE ducers, AE sensors, preamplifiers (if applicable), signal pro-
sources in composites (Sections 1114); wave propagation cessors (particularly the signal processor time reference), and
characteristics (Section 15); source or imperfection or discon- AE electronic waveform generator is performed. Equipment
tinuity location (Section 16); Kaiser effect/Felicity ratio (Sec- should be adjusted so that it conforms to equipment manufac-
tion 17); factors of significance in AE data (Section 18); in-situ turers specifications. Instruments used for calibration must
calibration of AE tests (Section 19); extraneous AE (Section have current accuracy certification that is traceable to the
20); and control checks on AE testing (Section 21). National Institute for Standards and Technology (NIST) or
7.4.3 AE Calibration and Standardization: equivalent national or regional (multinational) standards insti-
7.4.3.1 Consult Practice E569 for performing a location tute.
sensitivity check (includes a zone location sensitivity check 7.7.2 Routine electronic checks must be performed any time
and a source location algorithm sensitivity check). there is concern about signal processor performance. A wave-
form generator should be used in making evaluations.
7.4.3.2 Consult Guide E976 for performing sensor checks or
7.7.3 Routine sensor checks must be performed at any time
system performance checks using a pencil lead break.
there is concern about sensor performance. Peak amplitude and
7.5 Geometric and Size Considerations electronic noise level should be recorded. Sensors can be
7.5.1 Wave propagation signal losses are more considerable stimulated by a mechanical device such as a pencil lead break
in composites than in metals. There are three primary causes of or piezoelectric transducer. The object is to induce stress waves
amplitude attenuation of AE signals in composites during AE into the article under test at a specified distance from each
wave propagation: (1) geometric spreading (same as in metals, sensor. Induced stress waves stimulate a sensor in a manner
but metals dont typically have sensors directly over AE similar to emission from an imperfection or discontinuity.
sources; thus this can be quite large), (2) material absorption Sensors that have peak amplitudes or electronic noise greater
(much higher in composites than in metals), and iii) dispersion than the average, or sensitivities lower than the average of the
(different propagation velocities of different frequencies). In group of sensors being used should be replaced.
addition, depending on the geometry and size of the article 7.7.4 A system verification must be performed immediately
under test, reflections can also alter the expected attenuation. before and immediately after each examination. A system
7.5.2 In larger composite articles, there may be significant verification uses a mechanical device such as a pencil lead
manpower economies using sensors with integrated preampli- break or piezoelectric transducer to induce stress waves into
fiers to preclude the need to connect separate preamplifiers. the article under test. The induced stress wave must be
7.5.3 Since composites are in general anisotropic and of nondestructive. System verification validates the sensitivity of
varying thicknesses, the signal (wave) propagation losses may each system channel (including the couplant and test fixture).
vary in different parts of the composite. 7.8 Physical Reference Standards
7.6 Safety and Hazards 7.8.1 Not Applicable.
7.6.1 Pressure VesselsWhen conducting AE examination 8. Computed Tomography (X-ray Method)
of pressure vessels and RTRP, the following safety guidelines
8.1 Referenced Documents
shall be followed:
8.1.1 ASTM Standards:2
7.6.1.1 When testing in-service pressure vessels, all safety E1441 Guide for Computed Tomography (CT) Imaging
requirements unique to the examination location shall be meet. E1570 Practice for Computed Tomographic (CT) Examina-
Protective clothing and equipment that is normally used in the tion
area in which the examination is conducted shall be worn. E1670 Guide for Computed Tomography (CT) System Se-
7.6.1.2 The test temperature should not be below the lection
ductile-brittle transition temperature (b-relaxation) of the semi- E1935 Test Method for Calibrating and Measuring CT
crystalline matrix, or above the glass-rubber transition tem- Density
perature (a-relaxation or glass transition temperature) of the 8.2 General Procedure
amorphous matrix used the pressure vessel composite over- 8.2.1 CT is a radiographic inspection method that uses a
wrap. computer to reconstruct an image of a cross-sectional plane
7.6.1.3 Precautions shall be taken to protect against the (slice) through the article under test. CT consists of making
consequences of catastrophic failure when pressure testing, for penetrating radiation measurements of the X-ray opacity of the
example, flying debris and impact of escaping liquid. Pressur- article under test along many paths to compute a cross-
izing under pneumatic conditions is not recommended except sectional CT-mass attenuation density image called a tomo-
when normal service loads include either a superposed gas gram. The resulting cross-sectional image is a quantitative map
pressure or gas pressure only. Care shall be taken to avoid of the linear X-ray mass attenuation coefficient at each point in
overstressing the lower section of the vessel when liquid test the plane. The linear mass attenuation coefficient characterizes
loads are used to simulate operating gas pressures. the local instantaneous rate at which X-rays are attenuated

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
11
Downloaded/printed by
E2533 09
TABLE 6 Summary of Computed Tomography
What Is Seen
Applications How It Works Advantages Limitations
and Reported?
Allows the depth of sub- A penetrating X-ray Produces clear cross- CT scanners usually have A digitized cross-sectional
surface imperfections or radiation beam is passed sectional image slices of a upper limit on the part CT-density map
discontinuities to be through the article under an object. size, however specialized (tomogram) of the article
measured. test along many paths to scanners can be built for under test. Allows full,
compute a cross-sectional Because of the absence of large parts. Larger parts three dimensional CT-
Quantitative analysis of CT-density image called a structural noise from detail (composite fan blades) density maps to be
feature size and shape, tomogram. outside the thin plane of may require the use of obtained for sufficiently
feature density contrast, inspection, images are linear accelerator X-ray small articles under test.
wall thickness, coating The CT system acquires much easier to interpret. sources (1 MeV and
thickness, absolute many sets of projected higher).
material density, and X-ray data (also called Ideally suited for locating
average atomic number. views) from a DDA (either and sizing planar and Not very applicable to
1D or 2D), converts volumetric detail in three inspection of large areas.
Can perform, to a limited measured signal to a dimensions, for example,
extent, chemical digital format, and then imperfection or CT scans may take a long
characterization of the performs a reconstruction discontinuity distribution. time to both acquire and
internal structure of to compute a tomogram or reconstruct the data.
materials. 3D volume image set. Applies equally well to Scanning time is
metallic and non-metallic dependant on the size of
The CT systems today are specimens, solid and the part, the X-ray source
not limited to generating fibrous materials, and output, required resolution
tomograms. They can also smooth and irregularly and the detector geometry.
generate volume data, 3D surfaced objects.
visualization and Difficulty obtaining
reformatted, multi-planar Extensive image sufficient contrast between
reconstructions. processing possible. low atomic number
composite substructures
(for example, matrix, fiber,
laminae), especially for flat
panel based CT systems.
(obtaining sufficient
contrast is not a problem
for a high dynamic range
CT system).

Possibility of artifacts in the


data.

Tooling and/or multi-axis


part-handling fixtures may
be required.

during the scan, by scatter or absorption, from the incident 8.3.3 Computed tomography (CT) images are well suited
radiation as it propagates through the article under test. for use in making quantitative measurements. The magnitude
8.3 Significance and Use and nature of the error in CT-based measurements strongly
8.3.1 CT is usually performed after two dimensional X-ray depends on the particulars of the scanner apparatus, the scan
imaging. parameters, the object, and the features of interest. Among the
8.3.2 CT, as with conventional radiography and radioscopic parameters which can be estimated from CT images are feature
examinations, is broadly applicable to any material or exami- size and shape, feature density contrast, wall thickness, coating
nation object through which a beam of penetrating radiation thickness, absolute material density, and average atomic num-
may be passed and detected, including composite materials and ber.
components. The new user can learn quickly (often upon first
8.3.4 The use of such quantitative measurements requires
exposure to the technology) to read CT data because the
that errors associated with them be known. The precision of the
images correspond more closely to the way the human mind
measurement can best be determined by seeing the distribution
visualizes three-dimensional structures than conventional pro-
jection radiography. Further, because CT images are digital, of measurements of the same feature under repeated scans,
they may be enhanced, analyzed, compressed, archived, input preferably with as much displacement of the object between
as data into performance calculations, compared with digital scans as is expected in practice. This ensures that all effects
data from other NDT modalities, or transmitted to other which vary the result are allowed for; such as photon statistics,
locations for remote viewing. Additionally, CT images exhibit detector drift, alignment artifacts, spatial variation, variation of
enhanced contrast discrimination over compact areas larger the point-spread-function, object placement, and so forth.
than 20 to 25 pixels. This capability has no classical analog. 8.3.5 One source of such variation is uncorrected systematic
Contrast discrimination of better than 0.1 % at three-sigma effects such as gain changes or offset displacements between
confidence levels over areas as small as one-fifth of one percent different images. Such image differences can often be removed
the size of the object of interest is common. from the measurement computation by including calibration

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
12
Downloaded/printed by
E2533 09
materials in the image, which is then transformed so that the 8.3.11.4 Also, since the method is X-ray based, it applies
calibration materials are at standard values. equally well to metallic and non-metallic specimens, solid and
8.3.6 In addition to random variation, measurements of any fibrous materials, and smooth and irregularly surfaced objects.
particular feature may also have a consistent bias. This may be When used in conjunction with other nondestructive test
due to artifacts in the image or to false assumptions used in the (NDT) methods, such as ultrasound, CT data can provide
measurement algorithm. When determined by measurement of evaluations of material integrity that cannot currently be
articles under test, such biases can be removed by allowing for provided nondestructively by any other means.
them in the algorithm. 8.3.11.5 The principal advantage of CT is that it nondestruc-
8.3.7 Examination of the distribution of measurement re- tively provides quantitative densitometric (that is, density and
sults from repeated scans of articles with known features geometry) images of thin cross sections through an object.
similar to those which are the target of the NDT investigation Because of the absence of structural noise from detail outside
is the best method for determining precision and bias in CT the thin plane of inspection, images are much easier to interpret
measurements. Once such determinations have been made for than conventional radiographic data.
a given system and set of objects and scanning conditions;
NOTE 7The linear mass attenuation coefficient also carries an energy
however, they can be used to give well-based estimates of dependence that is a function of material composition. This feature may or
precision and bias for objects intermediate in size, composition may not (depending on the materials and the energies of the X-rays used)
and form, as long as no unusual artifact patterns are introduced be more important than the basic density dependence. In some instances,
into the images. this effect can be detrimental, masking density differences in a CT scan; in
8.3.8 With proper calibration, absolute density determina- other cases, it can be used to advantage, enhancing the contrast between
tions can also be made very accurately. Attenuation values can different materials of similar density.
also be related accurately to material densities. If details in the 8.3.12 Limitations and Interferences:
image are known to be pure homogeneous elements, the 8.3.12.1 As in the case radiography and radioscopy, perhaps
density values may still be sufficient to identify materials in the biggest challenge in X-ray CT as applied to composite
some cases. For the case in which no a priori information is materials and components is to obtain sufficient contrast
available, CT densities cannot be used to identify unknown between low atomic number composite substructures (for
materials unambiguously, since an infinite spectrum of com- example, matrix, fiber, laminae). While obtaining sufficient
pounds can be envisioned that will yield any given observed contrast is more difficult for flat panel based CT systems, this
attenuation. In this instance, the exceptional density sensitivity is not a problem for high dynamic range CT systems.
of CT can still be used to determine part morphology and 8.3.12.2 As with any modality, CT has its limitations. The
highlight structural irregularities. most fundamental is that candidate objects for examination
8.3.9 Because CT scan times are typically on the order of must be small enough to be accommodated by the handling
minutes per image, complete three-dimensional CT examina- system of the CT equipment available to the user and radio-
tions can be time consuming. Complete part examinations metrically translucent at the X-ray energies employed by that
demand large storage capabilities or advanced display tech- particular system. Further, CT reconstruction algorithms re-
niques, or both, and equipment to help the operator review the quire that a full 180 degrees of data be collected by the scanner.
huge volume of data generated. This can be compensated for Object size or opacity limits the amount of data that can be
by state-of-the-art graphics hardware and automatic examina- taken in some instances. While there are methods to compen-
tion software to aid the user. Thus, less than 100 % CT sate for incomplete data which produce diagnostically useful
examinations are often necessary or must be accommodated by images, the resultant images are necessarily inferior to images
complementing the inspection process with digital radio- from complete data sets.
graphic screening.
8.3.12.3 Another potential drawback with CT imaging is the
8.3.10 CT examination practices are generally part and possibility of artifacts in the data. As used here, an artifact is
application specific. Industrial CT usage is new enough that in anything in the image that does not accurately reflect true
many cases consensus methods have not yet emerged. The structure in the part being inspected. Because they are not real,
situation is complicated further by the fact that CT system artifacts limit the users ability to quantitatively extract mass
hardware and performance capabilities are still undergoing attenuation coefficients, density, dimensional, or other data
significant evolution and improvement. from an image. Therefore, as with any technique, the user must
8.3.11 Advantages and Applications: learn to recognize and be able to discount common artifacts
8.3.11.1 Unlike radiography or radioscopy, CT allows the subjectively. Some image artifacts can be reduced or elimi-
depth of defects to be observed. It can show small, specific nated with CT by improved engineering practice; others are
clusters of defects that give information not available in inherent in the methodology. Examples of the former include
conventional radiography. scattered radiation and electronic noise. Examples of the latter
8.3.11.2 CT is ideally suited for locating and sizing planar include edge streaks and partial volume effects. Some artifacts
and volumetric detail in three dimensions. are a little of both. A good example is the cupping artifact,
8.3.11.3 Because of the sensitivity of absorption cross which is due as much to radiation scatter (which can in
sections to atomic chemistry, CT permits, to a limited extent, principle be largely eliminated), as to the polychromaticity of
the chemical characterization of the internal structure of the X-ray flux (which is inherent in the use of bremsstrahlung
materials. sources). Specific artifacts for composite parts, especially ones

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
13
Downloaded/printed by
E2533 09
that have a large aspect ratios (like fan blades), and ways to envelope. Size, and therefore weight, will govern the type of
minimize artifacts by acquiring more projections or using mechanical subsystem that will be needed to move the article
different scanning geometries or adding bolus materials, are relative to the beam (article rotated or translated relative to a
not discussed here. stationary beam and source), or move the beam relative to the
8.4 Use of Referenced Documents article (beam source and detector system rotated around the
8.4.1 General: article). For example, a very different mechanical subsystem
8.4.1.1 Consult Guide E1441 for a general description of will be required to support and accurately move a large, heavy
X-ray CT (including a discussion of the theoretical basis of CT article than move a small, light article. Similarly, the logistics
imaging), CT system capabilities (spatial resolution, statistical and fixturing for handling a large number of similar items will
noise, artifacts), a glossary of terms that have meaning or carry be a much different problem than for handling an one-of-a-kind
implications unique to CT. Potential users and buyers, as well item. Larger articles, depending on material makeup, will in
as experienced CT inspectors, will find Guide E1441 a useful general attenuate the beam more, which will in turn govern the
source of information for determining the suitability of CT for type of radiation source and detectors, or both, that are needed.
particular examination problems, for predicting CT system 8.5.2 As a metrological tool, most CT systems provide a
performance in new situations, and for developing and pre- pixel resolution of roughly 1 part in 1000 (since, at present,
scribing new scan procedures. 1024 3 1024 images are the norm), and metrological algo-
8.4.1.2 Consult Guide E1670 when translating application rithms can often measure dimensions with acceptable accuracy
requirements into computed tomography (CT) system down to the subpixel range. For small objects (less than 4 in.
requirements/specifications, or to establish a common termi- in diameter), this translates into accuracies of approximately
nology to guide both purchaser and supplier in the CT system 0.1 mm (0.003 to 0.005 in.) at three-sigma. For much larger
selection process. objects, the corresponding figure will be proportionally greater.
8.4.2 CT Equipment and Instrumentation: NOTE 8Systems with 0.01 mm voxel resolution are currently avail-
8.4.2.1 Consult Guide E1441 and Practice E1570 for types able.
of subsystems present in modern CT systems. 8.5.3 The maximum height and diameter of a test article that
8.4.2.2 Consult Guide E1441 for a description of modern can be examined on a CT system defines the equipment
CT system subsystems (radiation sources, ionization and scin- examination envelope. The weight of the object and any
tillation detectors, mechanical scanning equipment, computer associated fixturing must be within the manipulation system
systems, operator interfaces, image display, and image process- capability. For example, a very different mechanical subsystem
ing). will be required to support and accurately move a large, heavy
8.4.3 CT Calibration and Standardization: test article than move a small, light test article. Similarly, the
8.4.3.1 Consult Guide E1441 for verification of CT perfor- logistics and fixturing for handling a large number of similar
mance parameters, interpretation of CT results. items will be a much different problem than for handling an
8.4.3.2 Consult Practice E1570 for requirements that are one-of-a-kind item.
intended to control the reliability and quality of CT images, 8.6 Safety and Hazards
whether by means of calibration, standardization, use of 8.6.1 CT examination procedures shall be carried out under
Physical reference standards, or inspection plans. Control of protective conditions so that personnel will not receive radia-
reliability and quality is also achieved by adopting uniform tion does levels dose levels exceeding that permitted by
procedures for CT system configuration, setup, optimization, company, city, state, or national regulations. All hazards and
and performance measurement. safe operating procedures that apply shall be identified, includ-
8.4.3.3 Consult Test Method E1695 determining the spatial ing:
resolution and contrast sensitivity in X-ray and -ray computed 8.6.1.1 Federal regulations,
tomography (CT) images. The spatial resolution measurement 8.6.1.2 Sate/local regulations,
is derived from an image analysis of the sharpness at the edge 8.6.1.3 Posting of area,
of the disk. The contrast sensitivity measurement is derived 8.6.1.4 Personnel monitoring,
from an image analysis of the statistical noise at the center of 8.6.1.5 Positioning table lockout, and
the disk. This test method may also be used to evaluate other 8.6.1.6 Area evacuation.
performance parameters such as: the mid-frequency enhance- 8.6.2 For additional information pertaining to radiation
ment of the reconstruction kernel, the presence (or absence) of Safety and Hazards associated with the use of X-ray equip-
detector crosstalk, the undersampling of views, and the clip- ment, refer to section 10.2.8.
ping of unphysical (that is, negative) CT numbers. 8.7 Calibration and Standardization
8.4.3.4 Consult Test Method E1935 for density calibration 8.7.1 CT examinations system performance parameters
of CT systems and for using this information to measure must be determined and monitored regularly to ensure consis-
material densities from CT images. tent results. The best measure of CT system performance can
8.5 Geometry, Size, and Weight Considerations be made with the system in operation, using the article under
8.5.1 SizeAside from weight and material makeup, the test under actual operating conditions.
most basic consideration will be the articles size. The maxi- 8.7.2 System performance measurement techniques should
mum height and diameter of the article under test that can be be standardized so that performance measurement tests may be
examined on a CT system defines the equipment examination readily duplicated at specified intervals. The CT examination

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
14
Downloaded/printed by
E2533 09
system performance should be evaluated at sufficiently fre- value. Its density can then be extracted from knowledge of its
quent intervals, as may be agreed upon by the supplier and the mass attenuation coefficient, or one representative of the
user of the CT examination services, to minimize the possibil- feature.
ity of time dependent performance variations. 8.8 Physical Reference Standards
8.7.3 Quantitative measurement of spatial resolution, 8.8.1 Performance measurements involve the use of a simu-
signal-to-noise resolution, contrast sensitivity, contrast-detail- lated composite article (also known as a test phantom) con-
dose curves shall be conducted in accordance with Practice taining actual or simulated features that must be reliably
E1570. detected and measured. A test phantom can be designed to
8.7.4 Density calibration of CT systems using disks of provide a reliable indication of the CT systems capabilities.
material with embedded specimens of known composition and Test phantom categories currently used in CT and simulated
density shall be performed in accordance with Test Method features to be imaged can be classified in accordance with
E1935. The measured mean CT values of the known standards Table 1 in Practice E1570.
are determined from an analysis of the image, and their linear
mass attenuation coefficients are determined by multiplying 9. Leak Testing
their measured physical density by their published mass 9.1 Referenced Documents
attenuation coefficient. The density calibration is performed by 9.1.1 ASTM Standards:2
applying a linear regression to the data. Once calibrated, the E427 Practice for Testing for Leaks Using the Halogen Leak
linear attenuation coefficient of an unknown feature in an Detector (Alkali-Ion Diode)
image can be measured from a determination of its mean CT E432 Guide for Selection of a Leak Testing Method

TABLE 7 Summary of Leak Testing


What Is Seen
Applications How It Works Advantages Limitations
and Reported?
Can be performed on any A flow of a fluid (liquid or For method-specific For method-specific Qualitative indications, for
composite material or gas) through a leak advantages of bubble, limitations of bubble, example bubbles, or
component (for example, produces a pressure or chemical penetrant, chemical penetrant, quantitative measurements,
filament-wound pressure concentration differential. halogen gas, hydrostatic, halogen gas, hydrostatic, for example, detector
vessels) in which a However, because the leak mass loss and pressure mass loss and pressure deflections, that ascertain
differential pressure exists is not manufactured change, mass change, mass the presence or
(by means of evacuation or intentionally the leak hole spectrometer, thermal spectrometer, thermal concentration of a leaking
pressurization) and where dimensions are unknown, conductivity, and ultrasonic conductivity, and ultrasonic fluid, either with or without
through-leakage or in- therefore, the quantity used leak testing, refer to the leak testing, refer to the the presence of a tracer
leakage of product, air, to describe the leak is the appropriate subsection. appropriate subsection. gas, are made on the low
water vapor, or other measured leak rate. pressure or low
contaminants over the Gives irrefutable evidence Test equipment costs concentration side of the
projected service life are of To improve sensitivity, a of through leaks compared increase as the required article under test.
concern. tracer gas is often used in to more ambiguous leak test sensitivity Depending on the
conjunction with a detector. methods such as liquid increases. technique chosen, leak
Leak testing involves either penetration. locations can be precisely
1) detection and location of Leak Detection and determined, or leak rates
leaks, or 2) leak rate LocationWhen articles More sensitive than from 0.05 to 10-13 Pa m3
measurement. under test have pressure volumetric leak detection s-1 (0.5 to 10-12 std cm3
boundaries accessible on techniques such as s-1) can be measured.
Used to 1) prevent material both sides, either tracer acoustic emission or
leakage loss, 2) prevent probe (pressurized ultrasound, for example.
hazards and nuisances components) or detector
caused by leakage, and 3) probe (evacuated Different techniques are
detect unreliable components) techniques available for
components whose can be used for leak characterization of large
leakage rates exceed location determination. leaks (with rates as high as
acceptance criteria. 10-2 Pa m3 s-1 (10-1 std
Leak Rate Measurement cm3 s-1)) and small leaks
Used detect material Leak rate measurement (rates less then 10-5 Pa m3
imperfections or techniques fall into two s-1 (10-4 std cm3 s-1)).
discontinuities such as categories: 1) static, and 2)
cracks and fissures. dynamic testing. In static
testing, the chamber into
Leak testing is which the tracer gas leaks
complementary to other is allowed to accumulate,
NDT methods that are while in dynamic testing,
sensitive to material the chamber is pumped
discontinuities. continuously or
intermittently to draw the
Can be used to measure gas into the detector.
the leak rate of articles
under test that are open
(both test surfaces are
accessible) or sealed (only
the external surface is
accessible).

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
15
Downloaded/printed by
E2533 09
E493 Test Methods for Leaks Using the Mass Spectrometer niques increase the sensitivity, the time for testing is also
Leak Detector in the Inside-Out Testing Mode increased. In dynamic testing, the chamber is pumped continu-
E498 Test Methods for Leaks Using the Mass Spectrometer ously or intermittently to draw the gas into the detector. A
Leak Detector or Residual Gas Analyzer in the Tracer Probe dynamic test can be performed in the shortest of time. The
Mode leakage rate measurement may consist of either placing the
E499 Test Methods for Leaks Using the Mass Spectrometer tracer gas within or around the article under test. In the former
Leak Detector in the Detector Probe Mode case, the article is pressurized and detector is connected to the
E515 Test Method for Leaks Using Bubble Emission Tech- lower pressure envelop surrounding the pressurized article. In
niques the latter case, the article is evacuated and detector is con-
E1002 Test Method for Leaks Using Ultrasonics nected to the evacuated article surrounded by a higher pres-
E1003 Test Method for Hydrostatic Leak Testing surized envelop containing the tracer gas.
E1066 Test Method for Ammonia Colorimetric Leak Test- 9.2.3 Choice of a Leak Testing MethodThe correct leak
ing test method optimizes sensitivity, cost, and reliability of the
E1603 Test Methods for Leakage Measurement Using the test. The best suited method will ultimately depend on the (1)
Mass Spectrometer Leak Detector or Residual Gas Analyzer in desired sensitivity, (2) type of leak test (leak detection and
the Hood Mode location determination versus leak rate measurement), and (3)
E2024 Test Methods for Atmospheric Leaks Using a Ther- type of article under test (open versus sealed) (Fig. 2). Methods
mal Conductivity Leak Detector are listed in the order of sensitivity (the higher a method is in
9.1.2 Military Handbooks and Standard:6 a given listing, the more sensitive it is).
MIL-L-25567D Leak Detection Compound, Oxygen Sys- 9.3 Significance and Use
tems 9.3.1 The leak test procedure, required sensitivity, and leak
9.1.3 ASNT Handbook:3 detection method, are subject to agreement between the pur-
Leak Testing, Volume 1, Nondestructive Testing Handbook chaser and supplier. Any requirement to determine leak loca-
9.2 General Procedure tion(s) and/or leakage rate shall be explicitly stated. If leak
9.2.1 Leak Detection and Location DeterminationTracer location determination is required, any requirement to perform
gas tests for purposes of leak location determination can be tracer probe mode (article under test can be evacuated) and
divided into tracer probe and detector probe techniques. When detector probe mode (article under test cannot be evacuated)
choosing either technique, it is important that the leak location detection shall be explicitly stated.
be attempted only after the presence of a leak has been 9.3.2 The equipment needed will depend on the leak Prac-
ascertained. The tracer probe technique is used when the article tice or Test Method used. Chemical penetrants, tracer gases,
under test is evacuated and the tracer gas is applied to the tracer gas leak standards, a leak detector, safety monitors,
outside of the pressure boundary of the article. The detector roughing pumps, auxiliary pumps, secondary pressure vessels
probe technique is used when the article under test is pressur- or chambers (for bombing), pressure gauges, dry air or nitrogen
ized with gases including the tracer gas (if used) and sampling (for washing nonleaking surface that have sorbed tracer gas,
of the leaking gas is performed at atmospheric pressure in for example), may also be needed. For example, when con-
ambient air. Leak location of individual leaks is often required ducting helium gas leak detection, a mass spectrometer leak
when it is necessary to locate and repair unacceptable leaks so detector will be needed. Consult the appropriate Test Method
that total leakage from the article under test can be brought or Practice for the specific equipment needed.
within acceptable limits. 9.3.3 Leak testing allows determination of the existence of
9.2.2 Leak Rate MeasurementAll leak rate measurements leak sites and, under proper conditions, the quantity of material
involving a tracer gas are based on flow of gas from the high passing through the leak sites.
to low pressure side of a pressure boundary through a pre-
9.3.4 Leakage rate depends on pressure, volume, and time
sumed leak. When tracer gases are used, instruments sensitive
so more than one set of test parameters can yield the same
to the tracer gas presence or concentration are used to detect
leakage rate. In general, the pressure used should simulate the
outflow from the low pressure side of the leak in the pressure
boundary. Where leak measurements of change in pressure or pressure the article under test would see in service; however,
volume of gas within a pressurized enclosure, the loss of this is not a requirement. If, for example, the test pressure
internal pas pressure or volume indicates the leakage has exceeds that seen in service, elastic deformation of the article
occurred through the pressure boundary. When evacuated or under test can cause uncharacteristically excessive leakage.
low pressure composite articles are surrounded by higher 9.3.5 Leak testing of composite materials and components
pressure media (for example, the atmosphere of a test chamber is primarily limited to closed articles under test which can be
containing gases at higher pressure), leakage can be detected sealed and then pressurized or evacuated, for example,
by loss of pressure in the external chamber or by rise in filament-wound pressure vessels.
pressure within the lower pressure composite article under test. 9.3.6 Leak testing of composite materials and components
Leak rate measurement techniques fall into two categories: (1) that are open and cannot be sealed with a known pressure
static, and (2) dynamic testing. In static testing, the chamber with gas or liquid inside is also possible. In this case, it is
into which the tracer gas leaks is not subjected to pumping, necessary to either bomb the article under test in a pressure
thereby allowing the gas to accumulate. While static tech- chamber in order to introduce tracer gas into the article under

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
16
Downloaded/printed by
E2533 09

FIG. 2 Guide for Selection of a Leak Test Method

test; or otherwise expose the article under test to tracer or nique is more rapid because the gas reaches the detector at a
penetrant liquid to determine if a leak exists. higher concentration, despite any streaming effects, that it does
9.3.7 It is important to distinguish between the sensitivity of with a detector probe which detects tracer pas which is highly
the instrument used to measure leakage and the sensitivity of diluted by atmospheric gases. In the detector probe mode, a
the test system using the instrument. The sensitivity of various higher pressure differential across the system may be used, and
test systems differ For example, a test using a mass spectrom- therefore leaks of a smaller conductance can be found. In using
eter leak detector normally has an ultimate sensitivity of either mode it is important that leak location be attempted only
4.5 3 10-15 mole/s (10-10 standard cm3/s) when the procedures after the presence of a leak has been verified.
involves the measurement of a steady-state gas leakage rate. 9.3.9 To measure leakage accurately using tracer gas meth-
This sensitivity can be increased to 4.5 3 10-19 mole/s (10-14 ods, all parts of the article under test must contain the same
standard cm3/s) by allowing an accumulation of the leakage amount of tracer gas. When the article under test contain air
before a leakage measurement is made. Conversely, if the test prior to introduction of the tracer gas, or when a tracer gas and
system uses the mass spectrometer leak detector in the inert gas are added separately, uniform distribution of tracer
detector-probe mode, the sensitivity can be 102 to 104 smaller gas may not be achieved.
than that of the mass spectrometer itself. 9.3.10 There is no composite component or material across
9.3.8 Leak location using tracer gases such as helium can be which a differential pressure exists (either due to pressurization
subdivided into a tracer probe and detector probe modes. The or vacuum) that does not leak to some extent. Absolute leak
tracer probe mode is used when the article under test is tightness is not possible. Any vessel must, therefore, have a
evacuated, and the tracer gas comes from a probe located maximum leakage rate specified. To determine the leakage rate
outside the article. The detector probe mode is used when the that can be tolerated, one must decide whether to consider the
article under test is pressurized with a tracer gas and testing is total component or system leakage, or the maximum allowable
done at atmospheric pressure. Usually the tracer probe tech- leakage from a single leak. Additional factors include shelf life,

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
17
Downloaded/printed by
E2533 09
product contained, its toxicity, legal requirements, conse- may take several forms: heated anode (most common), electron
quences of excessive leakage, product cost, leak testing cost, capture, and halide torch (least expensive). Operationally, ions
and customer requirements. are emitted from a hot plate to a collector. These positive ions
9.3.11 While it is more common to base accept/reject increase in proportion to the amount of halogen present.
criteria on a specified value for the maximum allowable 9.3.12.4 Hydrostatic Leak TestingHydrostatic testing re-
leakage rate for either the whole system or a single leak, go quires a composite component to be completely filled with a
no-go accept/reject criteria can also be used, for example, as liquid such as water. Pressure is slowly applied to the liquid
determined by Test Method E515 using bubble emission until the required pressure is reached. This pressure is held for
techniques. a required time at which point the component is inspected
9.3.12 Significance and use will also depend on the leak test visually to locate leaks or pressure on a gauge is recorded to
procedure used: determine the components total leakage rate. As a precaution-
9.3.12.1 Bubble Leak TestingThe bubble emission tech- ary procedure to save time, ultrasonic pretesting is recom-
nique is not intended to measure leakage rates, rather, are mended before hydrostatic testing to locate leaks larger than
intended to locate leaks on a go, no-go basis. They are also 4.5 3 10-7 mole/s (10-2 standard cm3/s).
useful in situations when a when a quantitative measurement is 9.3.12.5 Mass Loss and Pressure ChangeMethods to
not practical. The basic procedure involves creating a pressure determine mass loss and pressure change are generally used for
differential across a leak and observing for bubbles in a liquid large leaks. Pressure change methods are usually applicable to
medium on the low pressure side. Leak size can be approxi- gaseous system. No information is provided about the leak site.
mated by the size of the bubble. Leakage rate can be approxi- 9.3.12.6 Mass Spectrometer Leak TestingOne of the most
mated by the frequency of bubble formation. Procedurally, the sensitive types of leak test equipment is the mass spectrometer.
article under test is fixtured (to nullify buoyancy) and pressur- A mass spectrometer operates on the principle of sorting
ized. Then the indicating liquid (film or immersion) is brought ionized gases in an electric field in accordance with molecular
into contact with the component. This precludes the liquid weight. In a helium mass spectrometer, baffles with slits allow
from temporarily blocking a small leak which could cause He+ ions to pass through the detector while others are blocked.
acceptance of a leaking article. As long as they are not The number of He+ ions reaching the detector per unit time
detrimental to the article under test, the following fluids may be corresponds to the leakage rate. Test Methods E493 are used
used: water with wetting agent, methyl alcohol, ethylene for hermetically-sealed devices with internal volumes, and is
glycol, mineral oil, fluorocarbons, and glycerin. Precleaning of used primarily to determine in-leakage of air, water vapor, or
the article under test is required because surface contaminants other contaminant over the projected service life using prefill-
also may cause temporary blockage of leaks. From a practical ing (article under test can be sealed with a known pressure of
standpoint, any gas may be used to pressurize the article under helium) or bombing (article under test cannot be sealed with a
test. Changing the gas to a lower molecular weight and/or known pressure of helium). Test Methods E498 and E1603
lower the surface tension of the liquid relative to the surface of both are conducted on any composite article that can be
the article under test will generally enhance sensitivity. If air is evacuated and to the other side of which helium or other tracer
used, it must be pure to preclude contamination and temporary gas may be applied. The main difference between Test Methods
blockage of leak. Shop air is unsuitable to use in this E498 and E1603 is small amount of helium is sprayed on the
application (contains too much dirt, water, and/or oils). evacuated article under test in Test Methods E498, whereas the
NOTE 9The immersion fluid used for bubble testing must not cause entire evacuated article under test is exposed to an envelop of
crazing, environmental stress cracking, or swelling. Even reversible helium tracer gas in Test Methods E1603.
swelling may interfere with detection of leaks. 9.3.12.7 Bombing (back pressurization with tracer gas) has
NOTE 10The immersion fluid used for bubble testing of composite special significance relevance for composite articles under test
materials and components used in oxygen systems must meet the when it is necessary to ensure that performance characteristics
requirement of MIL-L-25567D.
will not be affected by in-leakage of air, water vapor, or other
9.3.12.2 Chemical Penetrant Leak TestingTwo classes of contaminants over the projected service life.
chemical penetrants are available: liquid tracers (tracer dye in 9.3.12.8 Thermal Conductivity TestingThese methods are
suitable solvent), and gaseous tracers (gases such as ammonia based on the principle that certain gases have markedly
or carbon dioxide with an appropriate color indicating agent). different thermal conductivities compared to air. Equipment
As a general rule, white light liquid tracer systems are inferior consists of two heated filaments in a bridge circuit. One
in terms of sensitivity compared to fluorescent liquid tracer filament is cooled by air, the other by the test gas. Any
systems. Test Method E1066 discusses the use of 1 to 100 % differences unbalance the bridge and can be related to leakage.
ammonia between 34.5 and 689.5 kPa (5 and 100 psig). The The two gases with the greatest difference in thermal conduc-
ammonia flows through leaks and reacts with a colorimetric tivity are hydrogen and helium, but testing can be performed
developer that is applied on the outside of the container using argon, carbon dioxide, neon, or Freon R-12. The test
producing a visible indication. methods described in Test Methods E2024 are useful locating
9.3.12.3 Halogen Gas Leak TestingHalogen leak testing and estimating the size of pressurized gas leaks, either as
can be used to indicate the pressure, location, and magnitude of quality control tests or as filed inspection procedures. Also,
leaks in closed vessels and is normally used for production they are valuable as pretests before more time consuming and
examination. The use of halogen gas as the pressuring medium sensitive leak tests are used. Thermal conductivity leak checks

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
18
Downloaded/printed by
E2533 09
are semi-quantitative in that leaks location is possible, but not also require special safety precaution to be taken. Some tracer
precise leak rate measurement (only an approximation is gases such as ammonia may attack polymeric matrices and
possible). Like bubble emission techniques, thermal fibers to varying degrees, potentially resulting in the loss of
conductivity-based techniques are also useful in a go, no-go physical and mechanical properties.
accept-reject test mode. 9.3.13.3 Halogen Gas Leak Testing:
9.3.12.9 Acoustic Emission Leak TestingConsult Practice (1) Advantages and ApplicationsThis test may be con-
E1211 for description of a passive method utilizing (1) ducted on any device or component across which a pressure
surface-mounted AE sensors, or (2) sensors attached by means differential of halogen tracer gas may be created, and on which
of acoustic waveguides that allow detection and location of the the effluent side of the area to be leak tested is accessible for
steady state source of gas and liquid leaking out of a pressur- probing with the halogen leak detector. Halogen gas detectors
ized system. Application examples to illustrate the use of AE to have high sensitivity and can operate in air.
detect leaks in a relief valve, ball valve, and a transfer line are (2) Limitations and InterferencesThe use of halogen gas
also given in Appendix X1 of Practice E1211. leak has been declining because of concerns about the effect of
9.3.12.10 Ultrasonic Leak TestingThis method is espe- these gases on the ozone layer. Disadvantages include spurious
cially useful for detecting large leaks that are great enough to indications due halogen-containing sources like cigarette
produce turbulent flow. Turbulent flow in a gas occurs when smoke and cleaning compounds. The decomposed products are
the velocity approaches the speed of sound in that gas, which toxic and corrosive. Furthermore, the anode operates at 900C
is of the order of 4.5 3 10-6 to 10-7 mole/s (10-1 to 10-2 (1650F) which makes this method unsuitable for flammable
standard cm3/s). This method is based on the fact that turbulent environments. There is a need to recalibrate regularly as
flow generates sound frequencies from audible up to 60 kHz. calibration changes with time. Many of these problems are
Both pressurized leaks (Test Method E1002, Method A) and obviated using electron capture detectors and sulfur hexafluo-
leaks in unpressurized or evacuated systems (Test Method ride as a tracer gas.
E1002, Method B). 9.3.13.4 Hydrostatic Leak Testing:
9.3.13 Method-specific advantages and applications and (1) Advantages and ApplicationsHydrostatic leak testing
limitations and interferences are as follows: is useful for quality control testing of containers (pressure
9.3.13.1 Bubble Leak Testing: vessels, tanks) that are used to retain liquids.
(1) Advantages and ApplicationsBubble leak testing can (2) Limitations and InterferencesThe interior and exte-
detect and locate leak sites accurately. The advantages of rior weld and joint where leaks often occur must be free of oil,
bubble testing are simplicity of operation, low cost, and grease, or other contaminants that might temporarily block or
relatively good sensitivity. The immersion technique is espe- mask the leak. Hydrostatic testing should not be performed
cially well suited for containers that can be sealed before test before a leak test using tracer gas or air. The liquid media may
and completely immersed. The liquid application technique is clog small leaks and cause later leaks to be inaccurate. The test
especially well suited for pressure vessels, tanks, spheres, or liquid must be equal to or above the ambient test temperature,
other large apparatus on which the immersion techniques are or droplets will form on the outside of the article under test.
impractical. 9.3.13.5 Mass Loss and Pressure Change:
(2) Limitations and InterferencesBoth immersion and (1) Advantages and ApplicationsTraditionally, mass loss
liquid film bubble emission techniques per Test Method E515 and pressure change measurements are used to determine large
cannot be used to measure leakage rate or total leakage. leakage rates. Pressure changes are usually measured on
Disadvantages include the need for cleanup, and the fact that gaseous systems.
leaks may not be detected due to lack of time, the possibility of (2) Limitations and InterferencesNo information is pro-
clogging. Immediate application of high pressure may cause vided about the leak site. Also, since pressure is temperature
large leaks to be missed in the liquid application (film) dependent, the test temperature must either remain constant, or
technique. Last, since bubble testing is based on visual be compensated for the use of ideal gas laws.
observation, it is subject to operator interpretation and visual 9.3.13.6 Mass Spectrometer Leak Testing:
acuity. (1) Advantages and ApplicationsThis test may be con-
9.3.13.2 Chemical Penetrant Leak Testing: ducted on any object to be tested that can be evacuated and to
(1) Advantages and ApplicationsOne of the chief advan- the other side of which helium or other tracer gas may be
tages of liquid and gaseous tracer is the low cost of use since applied.
little or no equipment is needed. This method gives a clear NoteArticles under test that can be evacuated to a
indication of leakage site location. reasonable test pressure in an acceptable length of time require
(2) Limitations and InterferencesChemical penetrant the article to be clean and dry and usually no larger the a few
leak tests are incapable of providing leakage rate information. cubic feet in volume. To accommodate larger volumes or
Furthermore, liquid tracers can temporarily clog a leak, thus dirty components, auxiliary vacuum pumps having a greater
masking leak detection. Use of liquid tracers also necessitates capacity than those used in the MSLD may be used in
cleaning of the article under test after application. Care must conjunction with the MSLD. The leak test sensitivity will be
also be taken during application so as not to create false reduced under these conditions.
indications. Precise leak location determination may also be (2) Limitations and InterferencesAs with any tracer gar
hampered by liquid spread. The dyes or chemical used may system, care should be taken to minimize false signals. For

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
19
Downloaded/printed by
E2533 09
example, using helium tracer gas, the natural background (5 information sought (leakage rate measurement or leak location
ppm) must be zeroed out before leak testing can proceed. determination). Suitable leak test methods are ranked in the
Surface fissures, paint, grease, oil, dirt, exposed elastomeric order of increasing sensitivity.
seals or plastic matrices, blind cavities or threads, etc., can sorb 9.4.2 Numerous leak test methods have been devised to
helium during bombing or pressurization, which can contribute detect, locate, and/or measure leakage. Most but not all
to the background signal, thus reducing sensitivity. Either one methods considered in this Guide have corresponding ASTM
of both procedures of dry air or nitrogen washing or baking Practices, Test Methods, or Guides. The primary leak test
parts for 30 min between bombing and testing will sometime methods are:
help reduce this background signal. Care must be taken to also 9.4.2.1 Bubble Leak TestingConsult Test Method E515
control the pressure, time, and dwell time after bombing or for procedures for detecting or locating leaks, or both, by
pressurization with tracer gas or results can vary substantially. bubble emission techniques in situation when a quantitative
Series leak with an unpumped volume between them represents measurement is not practical. The normal limit of sensitivity
a difficult, if not impossible problem in helium leak detection. for this test method is 4.5 3 10-10 mole/s (10-5 standard cm3/s).
This type of leak occurs with double lap joints, double o-rings, Two techniques are considered: (1) an immersion technique,
flat polymer gaskets, ferrule and flange fittings. and (2) a liquid application technique.
9.3.13.7 Thermal Conductivity Leak Testing: 9.4.2.2 Chemical Penetrant Leak TestingConsult Test
(1) Advantages and ApplicationsThese methods provide Method E1066 for leak testing of large single- and double-
highly sensitive leakage rate information and can locate leak walled tanks, pressure and vacuum vessels, laminated, lined- or
sites accurately. Advantages include cost of equipment and double-walled parts using an ammonia colorimetric method.
reduced sensitivity to contaminants in the ambient atmosphere, This method can be used on containers with welded, fitted, or
and simplicity of operation. Thermal conductivity leak testing laminated sections that can be sealed at their ends or between
may be used as a go, no-go accept-reject test. their outer and inner walls and that are designed for internal
(2) Limitations and InterferencesDisadvantages include pressures of 34.5 kPa (5 psig) or greater. Although Test Method
the limited types of gases that can be successfully used. Also, E1066 is designed primarily for components that inherently
leak rates can only be approximated. Since thermal conductiv- contain or will contain ammonia (large as large tonnage
ity detectors are sensitive to all gases that have a thermal refrigeration systems or fertilizer storage systems, it can be
conductivity value different from air, test sensitivity to a used to test critical parts or containers that will hold toxic or
particular tracer gas can be significantly altered by the presence explosive gases or liquids or as a quick test for other contain-
of background gases. The degree of sensitivity reduction will ers. Basic procedures are described based on the type of
be proportional to the difference between the thermal conduc- inspection used. These procedures should be limited to finding
tivity of the tracer gas versus interfering background gases. leakage indications of 4.5 3 10-12 mole/s (10-7 standard cm3/s)
Areas to be tested must be free of oil, grease, paint, water, and or larger. There are no applicable ASTM practices, test
other contaminants that might mask a leak or be drawn into the methods, or guides for chemical penetrant leak testing using
detector and clog the probe. other gaseous tracers such as carbon dioxide.
9.3.13.8 Ultrasonic Leak Testing: 9.4.2.3 Halogen Gas Leak TestingConsult Practice E427
(1) Advantages and ApplicationsBy using only the ultra- for testing and locating the sources of gas leaking at the rate of
sonic component that is generated by turbulent flow, fewer 2.2 3 10-14 mole/s (5 3 10-10 standard cm3/s) using a halogen
false signals are detected. Because of the highly directional leak detector (alkali-ion diode). The test may be conducted on
nature of ultrasound, the leak can usually be located accurately. any device or component across which a pressure differential
Ultrasound equipment is also easy to operate, measurements of halogen tracer gas may be created, and on which the effluent
can be made with the probe removed from the leak, and side of the area to be leak tested is accessible for probing with
materials which could clog a leak and mask detection, or the halogen leak detector. Five methods are described: (1)
otherwise necessitate post-test cleaning are not needed. Ultra- direct probing with no significant halogen contamination in the
sonic leak testing is also a valuable pretest before other more atmosphere, (2) direct probing with significant halogen con-
time consuming and more sensitive leak tests are employed, tamination in the atmosphere, (3) Shroud test, (4) air-curtain
such as helium leak detection or chemical penetrant leak shroud test, and (5) a high sensitivity accumulation test.
detection. 9.4.2.4 Hydrostatic Leak TestingConsult Test Method
(2) Limitations and InterferencesThe chief disadvantage E1003 for testing of components for leaks by pressurizing them
of ultrasound is the lack of sensitivity to small leakage rates inside with a liquid. This test method can be used on containers
(less than 10-2 standard cm3/s). Ultrasonic leak testing should which can be sealed at their ends and which are designed for
not be used to leak highly toxic or explosive gas leaks. Under internal pressure. Basic procedures are described based on the
certain conditions background noise produced by equipment type of inspection used. These procedures should be limited to
vibration and air movement due, for example, to wind, air- finding leakage indications of 4.5 3 10-9 mole/s (10-4 standard
cooled motors, aircrafts engines, pneumatic systems, etc., can cm3/s) or larger.
prevent detection of relevant leakage. 9.4.2.5 Mass Loss and Pressure ChangeThere are no
9.4 Use of Referenced Documents applicable ASTM standard practices, test methods, or guides.
9.4.1 Consult Guide E432 for assistance in selecting a leak 9.4.2.6 Mass Spectrometer Leak TestingFive ASTM test
test method depending on the type of item to be tested and methods are cited:

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
20
Downloaded/printed by
E2533 09
(1) Consult Test Methods E493 (tracer probe mode) for sensitivity) methods better suited to leak testing of complex-
procedures for determining leakage through the walls of shaped articles under test are described.
enclosures that can be sealed prior to leak testing. In the 9.4.2.7 Thermal Conductivity TestingConsult Test Meth-
procedures cited, both involve mass spectrometer helium leak ods E2024 for procedures for detecting the sources of gas
detection and have varying degrees of sensitivity depending on leaking at the rate of 4.5 3 10-9 mole/s (10-4 standard cm3/s) or
the internal volume, the strength of the enclosure, the time greater. The tests may be conducted on any object that can be
available for preparation of test, and on the sorption charac- pressurized with a tracer gas that is detectable by a thermal
teristics of the enclosure material for helium. After the article conductivity detector. The test sensitivity will vary widely
under test has been subjected to helium pressurization, it is depending on the tracer gas used.
placed in an evacuated chamber and output signal obtained
from a mass spectrometer leak detector (MSLD). In general 9.4.2.8 Ultrasonic Leak TestingConsult Test Method
practice, the sensitivity limits are from 4.5 3 10-14 to 4.5 3 E1002 for procedures for determining the location and/or
10-10 mole/s (10-9 to 10-5 standard cm3/s at 0C) for helium, estimating the size of gas leakage to atmosphere by the
although these limits may be exceeded by several decades in airborne ultrasonic technique (ultrasonic translation). In gen-
either direction in some circumstances. Two methods are eral practice, both Class I and Class II instruments are used
described: test part preparation by bombing, and test part with minimum detectable leak rates of 6.7 3 107 to 6.7 3 106
preparation by prefilling. mole/s (1.5 3 102 to 1.5 3 101 standard cm3/s at 0C). Two
(2) Consult Test Methods E498 (tracer probe mode) for methods are described; (1) measurement of leak location and
sensitive procedures for procedures for testing and locating the estimation of leak size in articles under test that can be
sources of gas leaking at the rate of 4.5 3 10-14 mole/s (10-9 pressurized, and (2) location of leak location in articles under
standard cm3/s) or greater using a Mass Spectrometer Leak test are not capable of being pressurized but capable of having
Detector or Residual Gas Analyzer. The test may be conducted ultrasonic tone placed/injected into the test area to act as an
on any object to be tested that can be evacuated and to the other ultrasonic leak trace source.
side of which helium or other tracer gas may be applied. The 9.5 Geometry and Size Considerations
article under test must be capable of withstanding 0.1 Pa 9.5.1 Articles under test that are amenable to leak testing
(approximately 10-3 torr). fall into two categories: (1) open units that are accessible on
NoteComposite articles that can be evacuated to a two sides, and (2) sealed units that are accessible on one side.
reasonable test pressure in an acceptable length of time require For practical considerations, filament-wound pressure vessels
the article to be clean and dry and usually no larger the a few belong to the latter category.
cubic feet in volume. To accommodate larger volumes or 9.5.2 Articles under test in which the diameter and length
dirty components, auxiliary vacuum pumps having a greater are not greatly different (such as composite tanks) may be
capacity than those used in the MSLD may be used in tested satisfactorily by simply adding a tracer gas. However,
conjunction with the MSLD. The leak test sensitivity will be when system with long or restricted geometries are tested,
reduced under these conditions. more uniform tracer distribution will be achieved by first
(3) Consult Test Methods E499 for procedures for testing evacuating to a few torr, and then filling with the test gas. The
and locating the sources of gas leaking at a rate of 4.5 3 10-13 latter must be premixed if it does not consist of 100 % tracer
mole/s (10-8 standard cm3/s at 0C) for helium. The test gas.
methods cited in Test Methods E499 differ from those cited in
9.5.3 In the case of small internal volumes or large leaks,
Test Methods E493, E498, and E1603 in that the effluent side
allowances must be made to perform leak testing immediately
of the article under test is accessible for atmospheric probing
after filling (vessel filled with tracer gas and sealed), pressur-
with a MSLD sampling probe. Both direct probe and accumu-
ization (vessel pressurized with tracer gas and sealed), or
lation testing methods are described.
bombing (sealed pressure vessel exposed to pressurized tracer
(4) Consult Test Methods E1603 (hood mode) for sensitive gas and outside-in leakage detected); or an alternate test
procedures for procedures for testing and locating the sources method for large leaks must be used, for example, bubble
of gas leaking at the rate of 4.5 3 10-14 mole/s (10-9 standard
testing or liquid bombing and subsequent weight change.
cm3/s) or greater using a Mass Spectrometer Leak Detector or
Residual Gas Analyzer. The test may be conducted on any 9.5.4 There are no size limitations for atmospheric pressure
object to be tested that can be evacuated and to the other side direct probe helium leak detection (for example, see Test
of which helium or other tracer gas may be applied. The article Methods E499 Test Method A). For parts up to several cubic
under test must be capable of withstanding 0.1 Pa (approxi- meters in volume, or portions of larger composite components,
mately 10-3 torr). atmospheric pressure accumulation testing can be performed
(for example, see Test Methods E499 Test Method B).
(5) Consult Test Methods E2024 for procedures for detect-
ing the sources of gas leaking at the rate of 4.5 3 10-9 mol/s 9.5.5 Liquid film bubble emission techniques are widely
(10-4 standard cm3/s) or greater. The tests may be conducted on applied to components that cannot be easily be immersed
any article under test that can be pressurized with a tracer gas because of size, and can be used with a vacuum box to test
that is detectable by a thermal conductivity detector. The test vessels that cannot be pressurized or where only one side is
sensitivity will vary widely depending on the tracer gas used. accessible.
Both scanning (nominal sensitivity) and accumulation (high 9.6 Safety and Hazards

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
21
Downloaded/printed by
E2533 09
9.6.1 Regardless of the type of leak testing being done, 9.7.6 Mass Spectrometer Leak TestingCalibrate the
safety considerations for personnel performing these tests must MSLD with a calibrated leak to read directly in Pa m3/s, or
be a paramount concern. standard cm3/s of helium, in accordance with the manufactur-
9.6.2 Reasonable precautions against releasing tracer gases ers instructions. Any leak detectors used in making leak tests
in the test area must be observed. For example, radioactive by these test methods are not calibrated in the sense that they
tracer gases are normally not used because of hazards associ- are taken to a standards laboratory, calibrated, and returned to
ated with their use. Unique hazards are associated with the use the job. Rather, the leak detector is used as a comparator
of ammonia and halogen gases. Consult the appropriate Mate- between a leak standard and the unknown leak. However, the
rial Safety Data Sheet (MSDS) to determine what safety sensitivity of the leak detector is checked and adjusted on the
measures must be used to ensure personnel exposure does not job so that a leak of specified size will give a readily
exceed mandated exposure limits. observable, but not off-scale reading. To verify sensitivity,
9.6.3 Gross leak test detection methods such as hydrostatic reference to the leak standard should be made before and after
testing, mass and pressure change methods, and ultrasonic a prolonged test. When rapid repetitive testing is required, refer
testing are not sensitive enough for quality control leak testing to the leak standard often enough to ensure that desired test
of containers used to retain toxic or explosive liquids and sensitivity is maintained.
gases.
9.7.7 Thermal Conductivity Leak TestingCalibration shall
9.6.4 Safety FactorWhere feasible, ensure that a reason-
able safety factor has been allowed between the actual opera- be performed prior to, during, and completion of testing at
tional leak requirement for the article under test and the intervals not to exceed 1 h. Failure of a calibration check to
maximum leak rate that can be measured during test. Usually obtain the same or greater response as the previous check shall
a factor of 10 is adequate. For example, if the maximum leak require that an evaluation or retest of all tested articles. The
rate for a article under test for satisfactory operation is leak detector shall be turned on and allowed to warm up and
4.5 3 10-11 mole/s (10-6 standard cm3/s), the measurement zeroed as specified by the manufacturer. The probe (sensor)
requirement during test should be 4.5 3 10-12 mole/s (10-7 then shall be moved across the standard leak at a distance not
standard cm3/s) or less. more than 1 mm (0.04 in.) from the standard leak orifice and
9.7 Calibration and Standardization moved not faster than 20 mm/s (0.8 in./s), and the detectors
9.7.1 Bubble Leak TestingSince leak size and leak rate are response observed. The standard shall be scanned several times
not quantitatively measured no equipment calibration is needed and the average indicated leakage rate will be the test accep-
or warranted. However, operator skill and training must be tance reading. The scanning distance and speed may have to be
sufficient to minimize repeatability and reproducibility errors. adjusted during calibration to improve the detector response;
9.7.2 Chemical Penetrant Leak TestingBy varying pen- however, under no circumstances shall the scanning parameters
etrant concentration, test pressure, and development time, leak used during calibration differ from this used during test. For the
rate sensitivity can vary significantly. Depending on whether accumulation method, the detector needs to be checked against
the minimum detectable leak rate or maximum test pressure is a known standard concentration of the tracer gas in air into the
more important, that variable is fixed and the remaining test volume during the accumulation time. For volumes differ-
variable is measured. ent form the test volume, a proportional adjustment shall be
9.7.3 Halogen Gas Leak TestingAny leak detectors used made. Leak detector response will change when test param-
in making leak tests by these test methods are not calibrated in eters such as scanning distance and speed are altered, thus
the sense that they are taken to a standards laboratory, changing the gas concentration the leak detector measures. Any
calibrated, and returned to the job. Rather, the leak detector is change in the scanning parameters from those used for cali-
used as a comparator between a leak standard and the unknown bration may cause a deduction in the test sensitivity and
leak. However, the sensitivity of the leak detector is checked instrument response.
and adjusted on the job so that a leak of specified size will give 9.7.8 Ultrasonic Leak TestingThe ultrasonic instrument
a readily observable, but not off-scale reading. To verify should be calibrated or have the sensitivity validated before
sensitivity, reference to the leak standard should be made
each initial use. This will in turn require the use of an
before and after a prolonged test. When rapid repetitive testing
appropriate leak standard and nitrogen regulator for calibration
is required, refer to the leak standard often enough to ensure
the air probe. Recalibration shall be conducted at the beginning
that desired test sensitivity is maintained.
of each shift or designated work period interval or when
9.7.4 Hydrostatic Leak TestingSince no actual measure-
abnormalities are observed using the same sensing frequency
ment is made of the leak rate, calibration is not needed.
as used in the initial calibration. When using the ultrasonic
However, sensitivity will depend on operator experience and
transmitter method (Test Method E1002, Method B), the
training. If ultrasonic pre-testing is performed, refer to
13.10.1.8 for ultrasonic instrument calibration and sensitivity sensitivity and generated amplitude shall be verified before
validation. each use. This can be done by placing the ultrasonic transmitter
in a container with a known leak that is equivalent to the leaks
9.7.5 Mass Loss and Pressure ChangeMass and pressure
measurement equipment shall be calibrated at periodic inter- that are being detected.
vals in accordance with the contractual agreement or estab- 9.8 Physical Reference Standards
lished internal procedure. 9.8.1 Not applicable.

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
22
Downloaded/printed by
E2533 09
TABLE 8 Summary of Radiography and Computed Radiology
What Is Seen
Applications How It Works Advantages Limitations
and Reported?
Used to detect sub-surface A high voltage electric General Overview: Film General Overview: Not General Overview: Actual
imperfections or charge is applied to a and some imaging plates generally sensitive to small imperfections or
discontinuities such as cathode to generate can be cut and placed surface cracks except discontinuities are imaged,
cracks, foreign material, electrons. The electrons almost anywhere on part. under perfect conditions. usually in actual size.
inclusions, porosity, fiber are then accelerated Requires crack-like defects Unable to determine depth
misalignment, lack of through a vacuum to a Additional Information: to be relatively deep and/or of imperfections or
bonding and other two and positively charged anode. wide for reliable detection. discontinuities without
three dimensional The point at which the Provides volumetric additional X-ray exposures
imperfections or electrons strike the anode inspection method (it Additional Information: from different directions.
discontinuities where the (target) is made of a dense inspects the entire volume Depth of volumetric
major axis of the material, (for example, of the material as opposed Radiation safety, imperfections and
imperfection or tungsten or copper.) When to just the surface). particularly in portable discontinuities can be
discontinuity is oriented this electron beam strikes applications, is a concern. determined from digital
parallel to the incident the target, the rapid Energy levels (penetrating images after calibration.
beam. deceleration of the ability) can be adjusted by Ideally, parts should be
electrons generates X-ray changing the accelerating moved to an X-ray facility. Additional Information:
Additional Information: radiation which is directed voltage. Transporting parts
toward the article under consumes time and Imperfection or
Can effectively be used to test. The amount of High sensitivity to material exposes parts to the risk of discontinuity depth can be
find foreign materials or transmitted radiation that thickness and density damage. determined by taking
foreign object debris (FOD) penetrates the part changes. additional parallax X-ray
in assemblies or composite depends on material Depth of defects not shots. such shots can be
parts. thickness, density, and Part geometry does not indicated (see next time consuming and
scattering effects. The affect direction of the X-ray column). expensive, however.
Can be used to verify transmitted radiation beam to a great extent.
completeness of assembly exposes a sheet of Sensitivity decreases with Imperfections or
of finished parts, for radiographic film creating a Provides a permanent increased part thickness. discontinuities are
example, look for missing two dimensional image of visual record of the generally reported by
parts, broken connections, the part (in digital X-ray, a inspection results (that is, Difficult to obtain sufficient length for linear
etc. digital imaging plate is film or digital images). (2 % or better) contrast imperfections or
used instead of X-ray film). between low to medium discontinuities, diameter for
Used to detect three Discontinuities show up on Can be portable with atomic number composite rounded imperfections or
dimensional defects that the film or digital image as appropriate equipment and substructures. discontinuities, and by
have a size in the direction changes in density relative adequate safety length and width for odd-
of the incident radiation to continuous regions. For precautions. Access to both sides of the shaped imperfections or
that is equal to or greater polymeric matrix composite article under test is discontinuities. Clusters or
than 1 to 2 % of the materials and components, CR allows inspection in a necessary. touching voids or porosity
thickness of the article soft X-rays having energies shorter time and without may also be reported if not
under test. of the order of 50 kV are and chemical processing Orientation of linear acceptable by the
generally used. and waste. imperfections or acceptance criteria.
Two dimensional cracks discontinuities in the part
are detectable only if may not be favorable. To
present an effective be detected, the crack
thickness equal to or plane must be nearly
greater than 1 to 2 % of parallel to the X-ray beam.
the thickness of the article
under test, and are in Not sensitive to laminar
proper alignment with the imperfections or
incident beam. discontinuities (for
example, delamination).

High initial cost including


X-ray machine, lead rooms
or portable shields, film
processing and reading
facilities, and positioning
equipment.

High recurring film (which


contains silver bromide)
and chemical costs, and
associated disposal issues.

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
23
Downloaded/printed by
E2533 09
TABLE 9 Summary of Radioscopy
What Is Seen
Applications How It Works Advantages Limitations
and Reported?
Widely used for rapid The physical principles Real-time and near real- Cannot be used in real Long-term records can be
scanning of articles with behind radioscopy and time radiological images time mode with articles obtained through motion
gross internal imperfections radiography are the same. are obtained. under test that are thick or picture recording, video
or discontinuities, Radioscopy differs, overly dense due to recording, or still
conducted before however, in that it consists In-motion or continuous excessive beam photographs.
radiographic inspection, for of real-time or near real- imaging is possible (well attenuation. The
example. time non-film detection. suited for process or combination with computer Remote viewing
Three-dimensional production line based integration allows systemsA TV or
In-motion or continuous information can be requirements. the improvement of image computer monitor allow
imaging during process or obtained using both static quality. remote viewing. Permanent
production line inspection. and dynamic radioscopic A permanent digital or records are made on
systems. photographic record can be Sensitivity and resolution of secondary recording media
Provides a rapid check of obtained. real-time systems are not (for example, a computer
dimensions and the Both manual and as good as can be hard drive, video tape
internal configuration within automated systems are Much lower operating costs obtained with film hardcopy or photograph).
composite materials and available. than radiography in terms radiography.
components. of time, manpower, and Actual flaws imaged,
Remote viewing material. For example, film Radioscopic systems tend usually in actual size or
Through manipulation, systemsAn X-ray processing costs are to be more specialized and known ratio after correction
radioscopy can provide sensitive vidicon television eliminated. less versatile than those of magnification. Depth of
information about the pickup tube and an X-ray used in film radiography. flaw is usually not
three-dimensional intensifier camera system Allows the observer to be indicated. Direction of
distribution of or a real time DDA in out of the range of Fluoroscopic and electronic planar defects can be
imperfections, defects, and connection with a computer hazardous radiation. imaging systems require determined if X-ray
discontinuities within a and/or video monitor is additional expensive exposures from different
composite material or used instead of film which Radioscopy has equipment. directions are analyzed or
component. converts X-rays to advantages over from calibrated digital
electrons thus allowing radiography for Permanent records usually images.
instant image reproduction characterization of suffer from loss of detail if
on a TV or computer nonsymmetrical articles not acquired with a Direct viewing systems
monitor. Compared to film under test because of the computer because they are The X-ray image is viewed
imaging, greater brightness three-dimensional made on secondary indirectly using a mirror or
is achieved using the capability when using recording media (for radiation barrier window to
above mentioned systems. mechanical motion of the example, a video tape or prevent direct eye
articles relative to the X-ray photograph). exposure to hazardous
Direct viewing systems beam. radiation.
The X-ray image is In dynamic systems, a
produced on a fluorescent Computed-aided higher X-ray flux level is
screen instead of film as in automated systems can required to develop a
radiographic systems, and incorporate software that suitable image compared
viewed indirectly using a allow automated defect to static systems. Also,
mirror or radiation barrier recognition and accept/ control of scatter and
window to prevent direct reject decisions to be careful alignment of the
eye exposure to hazardous made. source, article under test,
radiation. and detector is required.

In dynamic systems,
radiation handling
requirements, additional
shielding requirements,
and article under test
positioning devices usually
result in greater capital
equipment costs.

10. Radiography (RT), Computed Radiology (CR), 10.1.2 ASTM Standards Applicable to Radiography and
Digital Radiology (DR) with Digital Detector Array Computed Radiology:2
Systems, and Radioscopy (RTR) E94 Guide for Radiographic Examination
10.1 Referenced Documents E1742 Practice for Radiographic Examination
10.1.1 ASTM Standards Applicable to Radiography, Com- E1815 Test Method for Classification of Film Systems for
puted Radiology, Radioscopy and Digital Radiology:2 Industrial Radiography
E747 Practice for Design, Manufacture and Material Group-
E1817 Practice for Controlling Quality of Radiological
ing Classification of Wire Image Quality Indicators (IQI) Used
Examination by Using Representative Quality Indicators
for Radiology
E1025 Practice For Design, Manufacture, and Material (RQIs)
Grouping Classification of Hole Type Image Quality Indicators E2007 Guide for Computed Radiology (Photostimulable
(IQI) Used For Radiology Luminescence (PSL) Method)
E2002 Practice for Determining Total Image Unsharpness in E2033 Practice for Computed Radiology (Photostimulable
Radiology Luminescence Method)

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
24
Downloaded/printed by
E2533 09
TABLE 10 Summary of Digital Radiology with Digital Detector Arrays
What Is Seen
Applications How It Works Advantages Limitations
and Reported?
Used to detect sub-surface The physical principles Radiological images can be DR systems tend to be General Overview:
imperfections or behind DR systems, seen quickly (less than 15 s) more specialized and
discontinuities such as radioscopy and after the end of the X-ray less versatile than those Actual imperfections or
cracks, foreign material, radiography are similar to exposure. used in film radiography. discontinuities, internal
inclusions, porosity, fiber DR systems DR combines structure /geometries,
misalignment, lack of the advantages of High SNR images can be DR systems require internal/external damage,
bonding and other two and radioscopy and obtained over a large dynamic additional expensive and manufacturing
three dimensional radiography systems: near range with one DDA read. The equipment. variability are imaged;
imperfections or real-time non-film detection SNR may be significantly size can be adjusted in
discontinuities. with a geometrical and increased by averaging the software with calibration.
contrast resolution of film results of multiple images on a
DDAs work better than film or even better. Three- PC. Able to determine depth
radiography in applications dimensional information of imperfections or
requiring low dose/fast can be obtained using Near real-time radiological discontinuities with
sampling, where high multiple view imaging and images are obtained. second (additional) X-ray
throughput inspections are DDAs can also be used as image.
required, and in 3D studies part of a computed Images can be accumulated on
including CT (see Section tomographic system. Both the PC; with this technology a Long-term records can
8). manual and automated very high SNR can be obtained. be obtained through CD
systems are available. and DVD recording
Used to detect three Contrast sensitivity of less the media.
dimensional defects that Remote viewing 0.1% is achievable. Images are and should
have a size in the direction systemsan X-ray be viewed on a high
of the incident radiation sensitive real-time DDA in A large range of material contrast, high resolution
that is equal to or greater connection with a computer thickness can be inspected and high brightness TFT
than 0.5 % of the thickness and/or video monitor is within one image. monitor.
of the article under test used instead of film which
being examined. converts X-rays to Digital image processing can
electrons thus allowing extract the important
Also used for rapid instant image reproduction information (Filter, Zoom,
scanning of articles with on a TV or computer Contrast/Brightness Adjust).
internal imperfections or monitor. Compared to film
discontinuities. imaging, greater brightness A perfect copy of the images
and contrast is achieved can be obtained by storing the
Provides a check of using the above mentioned images on the PC and/or a CD/
dimensions and the systems. DVD.
internal configuration within
composite materials and A DDA captures X-rays by Much lower operating costs
components. means of a scintillator than radiography in terms of
which generates visible time, manpower, and material.
Through manipulation, DR light and then detects that For example, film processing
systems can provide light by a photo diode costs are eliminated.
information about the array. The diode array
three-dimensional quantizes the signal for DR systems have advantages
distribution of storage on a PC and over radiography for
imperfections, defects, and display on a computer characterization of
discontinuities within a monitor. nonsymmetrical composites
composite material or articles because of the three-
component. DR intrinsically has lower dimensional capability when
spatial resolution than film, using mechanical motion of the
May detect surface however magnification articles relative to the X-ray
features and imperfections. techniques can be used beam.
when higher resolution is
needed. Imperfection or discontinuity
volume can be calculated of
geometrical size and difference
in grey values on the PC.

DR systems enable the use of


computer-aided systems to
which automate defect
recognition and may
incorporate software that
automates accept/reject
decisions.
Software can control image
quality of the DR system and
ensure a permanent sufficient
quality level.

DR systems usually require


less X-ray exposure than a
comparable film or CR image.

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
25
Downloaded/printed by
E2533 09
E2104 Practice for Radiographic Examination Of Advanced Part 2: General Principles for Testing of Metallic Materials
Aero And Turbine Materials And Components Using X-Rays and Gamma Rays
E2445 Practice for Qualification and Long-Term Stability of EN 13068-1, Non-Destructive TestingRadioscopic
Computed Radiology Systems TestingPart 1: Quantitative Measurement of Imaging Prop-
E2446 Practice for Classification of Computed Radiology erties
System EN 13068-2, Non-Destructive TestingRadioscopic
10.1.3 ASTM Standards Applicable to Radioscopy:2 TestingPart 2: Check of Long Term Stability of Imaging
E1000 Guide for Radioscopy Devices
E1255 Practice for Radioscopy EN 13068-3, Non-Destructive TestingRadioscopic
E1411 Practice for Qualification of Radioscopic Systems TestingPart 3: General Principles of Radioscopic Testing of
10.1.4 ASTM Standard Applicable to Digital Radiology:2 Metallic Materials by X- and Gamma Rays
E2597 Practice for Manufacturing Characterization of Digi- 10.2 Radiography and Computed Radiology
tal Detector Arrays 10.2.1 General ProcedureX-ray radiography is a process
10.1.5 Federal Standards:6 whereby transmitted X-ray radiation is converted directly into
NBS Handbook 114 General Radiation Safety Installations an image that gives subsurface information about the imper-
Using Nonmedical X-ray and Sealed Gamma Sources up to 10 fection or discontinuity distribution within an article under test.
MeV7 To produce this image, a high voltage electric charge is applied
Title 10, Code of Federal Regulations (CFR), Part 20, Stan- to a cathode to generate electrons. These electrons are then
dards for Protection Against Radiation accelerated through a vacuum to a positively charged anode
Title 21, Code of Federal Regulations (CFR), (target). The target is made of a dense material such as tungsten
1020.40, Safety Requirements of Cabinet X-ray Systems or copper. When this electron beam strikes the target, the rapid
Title 29, Code of Federal Regulations (CFR), 1910.96, Ion- deceleration of the electrons generates radiation (X-rays in this
izing Radiation (X-rays, RF, etc.) case) which is directed toward the part. The penetrating ability
10.1.6 Military Handbooks and Standards:6 of X-ray radiation depends on material thickness, density, and
MIL-HDBK-728/5A Radiologic Testing scattering effects. In passing through matter, some of the
MIL-HDBK-733 Nondestructive Testing Methods of Com- X-rays are absorbed in proportion to the atomic mass of the
posite MaterialsRadiography material being traversed. In normal transmission, the attenu-
10.1.7 National Council on Radiation Protection and Mea- ated (modulated) beam that has traversed an article under test
surement (NCRP) Documents:8 contains very useful macroscopic information about the types
NCRP 49 Structural Shielding Design and Evaluation for of defects and discontinuities present in the matter that was
Medical Use of X-Rays and Gamma Rays of Energies up to 10 traversed. The penetrating radiation exposes a sheet of radio-
MeV graphic film or imaging plate (IP), creating an image of the part
NCRP 51 Radiation Protection Design Guidelines for (in digital X-ray, a digital imaging plate is used instead of
0.1100 MeV Particle Accelerator Facilities X-ray film). With modern equipment and instrumentation, it is
NCRP 91 Recommendation on Limits for Exposures to generally agreed that discontinuities can be detected which
Ionizing Radiation present to the axis of the incident beam a minimum dimension
10.1.8 SAE Standards:9 of 1 to 2 % of the thickness of the article under test.
SAE-ARP 1611, Revision A, Quality Inspection Proce- Discontinuities show up on the film or IP as changes in density
dures, Composites: Tracer Fluoroscopy and Radiography or grey value relative to continuous regions such as matrix
10.1.9 ASME Code:10 material.
ASME Boiler and Pressure Vessel Code, Section V Nonde- 10.2.2 Significance and UseThe principles discussed in
structive Examination, Code Case 2476, Radiography Using this guide apply broadly to penetrating radiation systems.
Phosphor Imaging Plate Although this document is written specifically for use with
10.1.10 European Standards:11 X-ray systems, the general concepts can be used for other
EN 14784-1, Non-Destructive TestingIndustrial Com- penetrating radiation systems, such as those employing
puted Radiography with Storage Phosphor Imaging Plates gamma-rays and neutrons, which involve equipment and ap-
Part 1: Classification of Systems plication details unique to those systems. By far the most
EN 14784-2, Non-Destructive TestingIndustrial Com- widely used radiographic technique for the inspection of
puted Radiography with Storage Phosphor Imaging Plates polymeric matrix composite materials and components is the
straightforward X-ray radiographic method, versus more spe-
7
cialized methods such as microradiography, stereo-
Available from National Technical Information Service (NTIS), U. S. Depart-
ment of Commerce, 5285 Port Royal Road, Springfield, VA 22161.
radiography, fluoroscopy, and neutron radiography.
8
Available from NCRP Publications, 7010 Woodmont Ave., Suite 1016, Be- NOTE 11Microradiography is particularly well-suited for obtaining
thesda, MD 20814.
9 images of thin articles under test of low density; for this reason it has
Available from Society of Automotive Engineers, Inc., 400 Commonwealth Dr.,
Warrendale, PA 15096-0001.
utility in composite material and component investigations. Modern
10
Available from ASME International, Information Central Orders/Inquiries, systems are based on micro or nanofocus tubes combined with film or
P.O. Box 2300, Fairfield, NJ 07007-2300. digital detectors. The detail and radiographic quality produced by this
11
Available from European Committee for Standardization (Electrotechnical), technique can be extremely good. However, there can be inherent
CENELEC Customer service (info@cenelec.org). difficulties when using low energy (soft) X-rays. One difficulty, depending

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
26
Downloaded/printed by
E2533 09
on the thickness of the article under test, and source-to-film or IP distance, image due to scatter, which, in turn, reduces contrast. Depend-
is that exposure times can be very long (on the order of hours) if no special ing on composite article thickness and composition, use of low
soft beam tubes with high anode current are chosen. accelerating potentials may increase the exposure time.
10.2.3 Advantages and ApplicationsSome of the types of 10.2.4.2 Another limitation of radiography is access to both
defects detected by X-ray radiography of polymeric matrix sides of the article under test is required. The film or IP is
composites include fiber/matrix debonding, impact or fatigue placed on one side and the X-ray generator is placed on the
damage, fabrication imperfections or discontinuities, voids, opposite side. High cost is the chief objection to film radiog-
porosity, inclusions, splice imperfections or discontinuities (for raphy. One-half of the average inspection cost may be for the
example, honeycomb core-to-core or core-to-structure splice radiographic film, corresponding film processing chemicals
imperfections or discontinuities), fiber orientation, resin con- (for example, silver bromide), and their disposal. Computed
tent variation, fiber breaks, and crushed core. Two-dimensional radiography (CR) does not need any chemicals and requires
defects such as cracks and delaminations are not detectable limited consumption of imaging plates only, since they are
unless they present an effective thickness of at least 1 to 2 % of reusable after scanning and erasure for several hundred times.
the thickness of the article under test, and are in appropriate Exposure of imaging plates can typically be performed using
alignment with the X-ray beam. lower keV X-rays and reduced exposure time compared to film.
10.2.3.1 X-ray radiography can also provide information 10.2.5 Use of Referenced Documents: Application:
about imperfection or discontinuity content and growth, resin 10.2.5.1 Consult Guide E94 for preferred radiographic ex-
content, fiber orientation (when boron or glass fiber markers or amination techniques and production methods related to radio-
tracers are used, for example), thermal effects, and failure graphic film recording (that is, energy selection, filters, mask-
mechanisms. Composite defects are classified in accordance ing, back-scatter protection, screens, exposure calculations);
with imperfection or discontinuity size. Small and large imper- radiographic film selection, handling, processing (automatic or
fections or discontinuities are readily detectable radiographi- manual), viewing (image quality, distortion), and storage;
cally. Very small scale defects cannot be detected radiographi- maintenance of inspection records; and a list of available
cally without the use of radiopaque tracers: reference radiograph documents. Guide E2007 describes the
(1) Large scale defects and discontinuities affecting wide basics of computed radiography and its applications.
areas or even the entire component attributable to fabrication 10.2.5.2 Consult Practice E1742 for the application and
anomalies (for example, omission of prepreg layers during control of the radiographic film method and Practice E2033 for
lay-up, faulty cure, incorrect compaction due to failure to close computed radiography. These practices are also written so that
the mold correctly). Such large scale defects and discontinui- they can be specified on the engineering drawing, specification
ties can lead to catastrophic failure. or contract. It is not a detailed how-to procedure to be used by
(2) Smaller scale defects that may be precursors of cata- the NDT facility and must therefore be supplemented by a
strophic failure can also be introduced during fabrication (for detailed written procedure.
example, voidage, local fiber misorientation, local variation on 10.2.5.3 Consult Practices E1742, E2033, E2445 or E2104
resin content, matrix shrinkage upon cure and/or aging, and for minimum requirements for the application and control of
unavoidable macrostructural features such as joints in prepreg the radiographic and CR method. For example, specific re-
sheet). quirements are given for qualification (personnel and test
10.2.4 Limitations and InterferencesPerhaps the biggest agency), safety (exposure areas, darkroom, viewing areas,
challenge in X-ray radiography as applied to composite mate- longterm stability tests), materials (film and non-film), equip-
rials and components is to obtain sufficient contrast between ment (radiation sources, film holders, screens, film viewers,
low to medium atomic number composite substructures (for film system classes, CR system classes, densitometers, film
example, matrix, fiber, laminae). Normally, a 2 % contrast is a viewing aids), and image quality indicators (IQIs), that, to-
reasonable minimum. It is often necessary to enhance contrast gether, are intended to control the quality of radiographic and
by using radiopaque materials or contrast agents. digital images.
10.2.4.1 In radiography of composites comprised of low and 10.2.5.4 Consult SAE ARP1611, Revision A for a radio-
medium density materials, diffuse scattered radiation forms a paque tracer inspection procedure that has demonstrated utility
high percentage of the total radiation reaching the film or IP. in characterizing imperfections or discontinuities in composite
This is due to the nature of the soft, low voltage radiation (as materials and components which are introduced inadvertently
low as 20 kV) used to image composites, which is inherently by cutting, machining, or drilling operations during fabrication.
less penetrating and more prone to scattering. While lower The types of imperfections or discontinuities detected by this
accelerating voltages can be successfully used without exces- procedure are delamination, breakout (usually splintering on
sive scattering in thin specimens, use of higher, more penetrat- exit side of a drilled hole or cut), microcracks (including matrix
ing voltages in thicker specimens can result in excessive cracking), fiber/resin pullout, and shredding (tearing of one or
overall film density or IP grey value, reducing contrast and more plies).
making the radiograph unreadable in terms of imperfection or 10.2.5.5 Consult MIL-HDBK-728/5A for a general discus-
discontinuity identification. Scatter is therefore a major prob- sion about the basic principles behind radiologic testing
lem when radiographing polymeric matrix composites. In (generation of a penetrating radiation beams, beam attenuation
general this presents a paradox for the radiographer since low and absorption characteristics, detection systems), basic pro-
voltages improve contrast, but can also lead to fogging of the cedures and techniques, IQIs, applications, guidelines for use

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
27
Downloaded/printed by
E2533 09
by personnel (design engineers, production engineers, QA 10.2.7.1 Test GeometryThe relative geometric placement
personnel, NDT engineers and technicians), and safety. of source, the article under test, and film (or non-film detection
10.2.5.6 Consult MIL-HDBK-733 for information on X-ray device) is critically important for the following reasons: (1) the
radiographic techniques for examining defects and discontinui- area of exposure is usually a function of the distance of the
ties in reinforced composites (including delamination, fiber/ article under test from the source, (2) the intensity of the beam
matrix debonding, impact or fatigue damage, fabrication im- and exposure time required is a function of the distance
perfections or discontinuities, fiber misorientation, resin between the source and the film (or non-film detection device),
content variation, and fiber breaks), computer-based image (3) the magnification factor between the image and the article
enhancement techniques (including electronic enhancement, under test is the ratio of the detector-source distance (dd) to the
signal processing, removal of unwanted features), and use of article-source distance (ds), and (4) the sharpness of the image
opaque additives (impregnation procedures). will be a function of the difference between dd and ds times the
effective diameter of the source. In CR systems, unsharpness in
10.2.5.7 Consult MIL-HDBK-733 for information on mi-
the image can also result from limited spatial resolution of the
croradiographic imaging of thin specimens of polymeric matrix
IP and scanner (80260 m unsharpness corresponds to
composites, including discussion about techniques, effects of
40130 m basic spatial resolution or effective pixel size).
low voltage radiation, and X-ray tube window effects.
10.2.5.8 Consult EN 14784-1 for a discussion of: 1) CR NOTE 12Optimum geometrical sharpness of the image is obtained
quality indicators (including descriptions of CR quality indi- when the radiation source is small, the distance from the source to the
article under test is large, and the distance from the article to the detector
cators for user and manufacturer tests, application procedures
(for example, the film) is small. The magnification factor approaches unity
for CR quality indicators, image plate fading), 2) procedures under these conditions, and usually radiographic magnification will be
for quantitative measurement of image quality parameters close to unity unless an extremely small focal spot was purposely designed
(including descriptions of measurement of the normalized into the X-ray system.
signal to noise ratio, measurement of minimum read out
10.2.7.2 Composite Article ThicknessAs the thickness of
intensity, determination of unsharpness, and other tests, and 3)
a article under test increases, the time required to obtain a
CR system classification and interpretation of results (includ-
radiograph also increases. Therefore, for a given X-ray energy,
ing descriptions of range of CR system classification and
there exists a maximum thickness above which radiography is
determination of CEN speed).
not feasible due economic (time) considerations, and a mini-
10.2.5.9 Consult EN 14784-2 for a discussion of the general mum thickness below which radiography is not feasible due to
rules for industrial CR using storage phosphor imaging plates beam detector saturation and loss of contrast.
(IP), including a classification of CR techniques, general 10.2.7.3 Observable Defect SizesX-ray radiography is
considerations (surface preparation, identification of radio- capable of detecting three dimensional defects that have a size
graphs, marking, overlap of phosphor imaging plates, image in the direction of the incident radiation that is equal to or
quality indicators), and recommended techniques for making greater than 1 to 2 % of the thickness of the article under test.
computed radiographs (test arrangements, choice of voltage Two dimensional cracks are detectable only if they present an
and radiation source, phosphor imaging plate-scanner systems effective thickness equal to or greater than 1 to 2 % of the
and screens, system unsharpness, beam alignment, reduction of thickness of the article under test, and the crack plane is
scattered radiation, source-to-object distance, maximum area parallel or nearly parallel to the incident beam.
for a single exposure, minimum read-out intensity, and monitor
10.2.8 Safety and Hazards:
and film viewing conditions).
10.2.8.1 The basic principles that govern radiation safety
10.2.6 Use of Referenced Documents: Equipment, Instru- are (1) allowable working time, (2) working distance, and (3)
mentation, and Materials: shielding. Safe radiographic procedures employ these con-
10.2.6.1 Consult Guides E94 and E2007, Practices E1742, cepts.
E1815, E2033, E2445, E2446 and E2104, and MIL-HDBK- 10.2.8.2 The safety procedures for the handling and use of
728/5A for information about radiographic instrumentation and ionizing radiation sources must be followed. Mandatory rules
equipment, for example, area shielding equipment, cassettes, and regulations are published by governmental licensing agen-
darkroom, monitors, densitometers, diaphragms and collima- cies. Careful radiation surveys should be made in accordance
tors, digitizing techniques, exposure areas, film systems, im- with regulations and codes and should be conducted in the
aging plate systems, film processing solutions, film, film examination area as well as in adjacent areas under all possible
holders, identification and orientation markers, linear and operating conditions.
angular measuring devices, non-film radiographic recording 10.2.8.3 Issues associated with personnel protection against
media, penetrameters (IQIs), positioning devices, identification X-rays and gamma-rays are not covered by this document. For
and orientation markers, viewing areas, X-ray tube windows, information on personnel protection, refer to documents issued
X-ray sources, etc. by the National Committee on Radiation Protection and
10.2.6.2 Consult SAE ARP1611, Revision A for information Measurement, Federal Register, U.S. Energy Research and
about radiopaque tracer materials used to detect and size Development Administration, National Institute of Standards
imperfections or discontinuities in composite materials and and Technology (NIST) (formerly the National Bureau of
components. Standards), and to state and local regulations, if such exist. For
10.2.7 Geometry and Size Considerations: specific radiation safety information, refer to NIST Handbook

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
28
Downloaded/printed by
E2533 09
114, 10 CRF 20, 21 CFR 1020.40, and 29 CFR 1910.1096 or 10.2.10.2 Image Quality Indicators (IQIs)Penetrameters
state regulations for agreement states. are very important for measuring radiographic quality level;
10.2.8.4 Radiographic examination procedures shall be con- however, they are not always sufficient since they do not
ducted under protective conditions so that personnel will not always represent actual defects or imperfections or disconti-
receive radiation dose levels exceeding that permitted by nuities being sought. In this case, reference blocks or repre-
company, city, state, or national regulations. The recommen- sentative quality indicators in accordance with Practice E1817
dations of the National Committee on Radiation Protection shall be used.
(NCRP) should be a guide to radiation safety. NRCP 49, NCRP 10.2.10.3 Reference BlocksThe reference block may be
51, NRCP 91, and NIST Handbook 114 may be used as guides an actual object with known defects and imperfections or
to ensure the radiographic or radioscopic procedures are discontinuities that are representative of the range of defects
performed so that personnel shall not receive a radiation dose and imperfections or discontinuities to be detected, or may be
exceeding the maximum permitted by city, state, or national fabricated to simulate the article under test with a suitable
codes. range of representative defects and imperfections or disconti-
10.2.8.5 Electrical SafetyThe radiographer must comply nuities. A suitable range, for example, might include defects
with safe electrical practices when working with X-ray equip- and imperfections or discontinuities both in the acceptable and
ment. Modern X-ray equipment uses high voltage circuits. unacceptable range. Alternatively, the reference block may be
Permanently installed X-ray facilities are designed so that a one-of-a-kind reference object containing known imperfec-
personnel will encounter few electrical hazards; however, use tions that have been verified independently. Reference blocks
of portable X-ray equipment requires that added precaution be containing known, natural defects are useful on a single-task
taken such as insuring that units are grounded appropriately, basis, but are not universally applicable. Where standardization
power cables are free from wear, and condensers are dis- among two or more radiographic examination systems is
charged prior to checking of circuits. required, a duplicate manufactured reference block should be
10.2.9 Calibration and Standardization: used. The reference blocks should approximate the object as
10.2.9.1 Radiographic Quality LevelThe quality level closely as is practical, being made of the same material with
required for radiography is 2 % unless a higher or lower value similar dimensions and features in the examination region of
is agreed upon by the purchaser and supplier. At the 2 % interest. Manufactured reference blocks should include fea-
subject contrast level, three quality levels of inspection are tures at least as small as those that must be reliably detected in
available: 2-1T, 2-2T, and 2-4T (see Practice E1025). If IQIs of the actual article under test. Where features are internal to the
material radiographically similar to the article under test are article under test, it is permissible to produce the reference
not available, IQIs of the required dimensions but of a lower block in sections. Reference block details are a matter of
absorption material may be used. If film density varies by more agreement between the user and the supplier of radiographic
+30 to 15 % from the density measured through the body of and radioscopic examination services.
the IQI, two IQIs may be used so that the required sensitivity 10.2.10.4 Use of a Reference BlockThe reference block
is attained for the most and least dense portions of the should be placed in a radiographic or radioscopic system in the
radiograph. same position as the article under test and may be manipulated
10.2.9.2 Total Image Unsharpness (Spatial Resolution) (in the case of radioscopy and tomography) through the same
Conventional IQIs described in Practices E747 and E1025 range of motion through as given exposure that the article
combine the contrast sensitivity and resolution measurements under test is subjected to.
into an overall figure of merit. Such figures of merit may not be 10.3 Radioscopy
adequate to detect subtle changes in the imaging systems 10.3.1 General ProcedureRadioscopy consists of real-
performance. When it is determined necessary to evaluate and time or near real-time nonfilm detection, display, and recording
measure the total image unsharpness (spatial resolution) of an of radiological images. Like all X-ray transmission NDT
imaging system separately and apart from contrast sensitivity methods, radioscopy is based on the attenuation of X-rays
measurements, a tool or gauge as described in Practice E2002 during their passage through an article under test. Additionally,
can be used. significant spatial spreading occurs due to system imperfec-
10.2.9.3 DensitometersCalibrate prior to each use, using tions, nonsymmetric radiation transport, and the image forma-
calibrated film strips. tion process. Significant variations in the recorded radiation
10.2.10 Physical Reference Standards: near edges and material discontinuities therefore occur and
10.2.10.1 Radiographic Acceptance StandardsWhenever manifest themselves by intensity variations in the radioscopic
possible, a series of radiographs that exhibit the same types and image.
sizes of imperfections or discontinuities and acceptance vari- 10.3.2 Significance and UseAs with conventional radiog-
ables should be utilized. These radiographs are referred to raphy, radioscopic examination is broadly applicable to any
radiographic acceptance standards, and are used by the composite material or component through which a beam of
radiographer to determine if the radiographs being inspected penetrating radiation may be passed and detected. Although
meet or exceed these radiographic standards. While such closely related to radiography, radioscopy has much lower
standards are available for certain metallic alloys, they may not operating costs in terms of time, manpower, and material. In
be available for composite materials and components that are addition to the benefits normally associated with radiography,
representative to those being tested. radioscopic examination may be either a dynamic, filmless

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
29
Downloaded/printed by
E2533 09
technique allowing the examined part to be manipulated and compared to static scenes. Product-handling considerations in a
imaging parameters optimized during examination; or a static, dynamic imaging system mandate that the image plane be
filmless technique wherein the examined part is stationary with separated from the surface of the product resulting in percep-
respect to the incident radiation. Recent technology advances tible image unsharpness. Limitations imposed by a dynamic
in the area of projection imaging, detectors, and digital image system make control of scatter and geometry more difficult
processing provide acceptable sensitivity for a wide variety of than in conventional radiographic systems. Lastly, dynamic
applications. radioscopic systems require careful alignment of the source,
10.3.2.1 Both manual and computer-aided automated radio- article under test, and detector. Radiation handling require-
scopic systems of varying complexity are used. Systems ments and positioning devices peculiar to dynamic systems
having a wide range of capabilities between these two extremes usually result in greater capital equipment costs than in
can be assembled. conventional static radiography.
10.3.2.2 Radioscopy can be a versatile nondestructive tool. 10.3.5 Use of Referenced Documents:
It provides immediate information regarding the size, location, 10.3.5.1 Consult Guide E1000 for a tutorial outline of the
and distribution of imperfections, both internal and external. general principles of radioscopic imaging. The guide describes
By manipulation of the source relative to the composite practices and image quality measuring systems for real-time,
structure being examined, three-dimensional information about and near real-time, nonfilm detection, display, and recording of
the sizes and relative position of items of interest within the radioscopic images. These images, used in materials examina-
composite material or component can be obtained. Radioscopy tion, are generated by penetrating radiation passing through the
permits timely assessments of product integrity, and allows subject material and producing an image on the detecting
prompt disposition of the product based on acceptance stan- medium. The image detection and display techniques are
dards. nonfilm, but the use of photographic film as a means for
10.3.2.3 Long-term records of the radioscopic image may permanent recording of the image is not precluded. Guide
be obtained through motion-picture recording (cinefluorogra- E1000 also includes descriptions of different radioscopic
phy), video recording, or still photographs using conven- system configurations (X-ray/light conversion systems involv-
tional cameras. The radioscopic image may be electronically ing fluorescent phosphors or scintillation crystal imagining
enhanced, digitized, or otherwise processed for improved devices, and X-ray/electron conversion systems involving
visual image analysis or automatic, computer-aided analysis, or semiconductor junctions or microchannel plate imaging de-
both. vices), radiation sources (low- and high-energy radioactive
10.3.2.4 Since there are many methods for real-time and isotope sources, source geometry), display and recording
near real-time detection of radiation, its energy, and flux devices, and image quality considerations.
density, there are a number of possible systems. Radioscopic 10.3.5.2 Consult Practice E1255 for application details for
systems are conveniently classified into two main categories: radioscopic examination using penetrating radiation. This in-
(1) those based on conversion of X-rays into light using cludes dynamic radioscopy and, for the purposes of this
phosphors, scintillators, or X-ray intensifiers (direct viewing practice, radioscopy where there is no motion of the object
systems) and (2) those based on conversion of X-rays into during exposure (referred to as static radioscopic imaging).
electrons using semiconductors junctions or microchannel Since the techniques involved and the applications for radio-
plates (remote viewing systems). scopic examination are diverse, this practice is not intended to
10.3.3 Advantages and ApplicationsRadioscopy is pre- be limiting or restrictive, but rather to address the general
ferred when information about the three-dimensional distribu- applications of the technology and thereby facilitate its use.
tion of imperfections, defects, and discontinuities within a The general principles discussed in this practice apply broadly
composite material or component is needed. Radioscopy pro- to penetrating radiation radioscopic systems. Practice E1255
vides a rapid check of dimensions and the internal configura- also includes discussion on minimum system configuration,
tion within composite materials and components, and may be practice, system performance, and performance measurement.
used to assess the real-time functioning of a composite material 10.3.5.3 Consult Practice E1411 for test and measurement
or component. Radioscopy has advantages over radiography details for measuring the performance of radioscopic systems.
for characterization of nonsymmetrical articles under test Since radioscopic examination applications are diverse, system
because of the three-dimensional capability when using me- configurations are also diverse and constantly changing as the
chanical motion of the article relative to the X-ray beam. technology advances. This practice is intended as a means of
10.3.4 Limitations and InterferencesAs in radiography, initially qualifying and requalifying a radioscopic system for a
perhaps the biggest challenge in X-ray radioscopy as applied to specified application by determining its performance level
composite materials and components is to obtain sufficient when operated in a static mode. System architecture including
contrast between low atomic number composite substructures the means of radioscopic examination record archiving and the
(for example, matrix, fiber, laminae). Accordingly, it is often method for making the accept/reject decision are also unique
necessary to enhance contrast by using radiopaque materials or system features and their effect upon system performance must
contrast agents. Despite numerous advances in radioscopic be evaluated. The general principles, as stated in this practice,
systems, sensitivity and resolution of real-time systems usually apply broadly to transmitted-beam penetrating radiation radios-
are not as good as can be obtained with film. Dynamic scenes copy systems.
require a higher X-ray flux level to develop a suitable image 10.3.6 Geometry and Size Considerations:

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
30
Downloaded/printed by
E2533 09
10.3.6.1 Radioscopy is well suited for characterization of the actual article under test and may be manipulated through
nonsymmetrical articles because of the three-dimensional ca- the same range of motions through a given exposure for
pability when using mechanical motion of the articles relative dynamic radioscopic systems as are available for the actual
to the X-ray beam. object so as to maximize the radioscopic examination systems
10.3.6.2 Considerations about test geometry (relative place- response to simulated imperfections.
ment of source, article under test, and imaging devices), article 10.4 Digital Radiology (DR) with Digital Detector Array
thickness, and observable defect sizes are covered in 10.2.7 (DDA) Systems
(Radiography). 10.4.1 General ProcedureA DR system consists of near
10.3.7 Calibration and Standardization: real-time nonfilm radiological images acquisition, display, and
10.3.7.1 Reference StandardsReference radiographs pro- storing. Like all X-ray transmission NDT methods, DR sys-
duced by ASTM and acceptance standards written by other tems are based on the attenuation of X-rays during their
organizations may be employed for radioscopic examination as passage through an article under test.
well as for radiography, provided appropriate adjustments are 10.4.2 Significance and UseAs with conventional radiog-
made to accommodate for the differences in the fluoroscopic raphy, DR system examination is broadly applicable to any
images. composite material or component through which a beam of
10.3.7.2 Reference StandardsReference radiographs pro- penetrating radiation may be passed and detected. Although
duced by ASTM and acceptance standards written by other closely related to radiography, DR systems have much lower
organizations may be employed for radioscopic examination as operating costs in terms of time, manpower, and material. In
well as for radiography, provided appropriate adjustments are addition to the benefits normally associated with radiography,
made to accommodate for the differences in the fluoroscopic DR system examination may be either a dynamic, filmless
images. technique allowing the examined part to be manipulated and
10.3.7.3 Image Quality ConsiderationsImage quality is imaging parameters optimized during examination; or a static,
governed by two factors, image contrast and image resolution. filmless technique wherein the examined part is stationary with
A number of different approaches to assessing image quality respect to the incident radiation. Recent technology advances
are discussed in Section 11 of Guide E1000. in the area of X-ray tubes, detectors, and digital image
10.3.7.4 Use of Duplex Wire Gauge and Step WedgeA processing provide acceptable sensitivity for a wide variety of
duplex wire gauge, as described in Practices E1255 and E2002, applications.
and step wedge may be used, if so desired, to determine and 10.4.2.1 The images from a DR system provide a very large
track radioscopic system performance in terms of spatial number of grey levels (up to 65 000). Therefore DR systems
resolution and contrast sensitivity. The duplex wire gauge is are always computer-aided; image processing functions are
used without an additional absorber to evaluate system spatial necessary to operate a DR system. Powerful image processing
resolution. The step wedge is used to evaluate system contrast tools are available on the market.
sensitivity. 10.4.2.2 DR systems can be versatile nondestructive tools.
10.3.7.5 Equipment QualificationsA listing of the system They provide immediate information regarding the size, loca-
features that must be qualified to ensure that the system is tion, and distribution of imperfections, both internal and
capable of performing the desired radioscopic examination external. By manipulation of the source relative to the com-
task. Additionally, radioscopic system qualification shall be in posite structure being examined, three-dimensional informa-
accordance with Practice E1411 and can best be evaluated with tion about the sizes and relative position of items of interest
IQIs similar to the imperfection or discontinuity type being within the composite material or component can be obtained.
examined. DR systems permit timely assessments of product integrity,
10.3.8 Safety and Hazards: and allow prompt disposition of the product based on accep-
10.3.8.1 A general discussion about radiological safety and tance standards.
hazards and applicable Federal and NCRP documents are given 10.4.2.3 The DR system image may be electronically en-
in section 10.2.8 (Radiography and Computed Radiology). hanced or otherwise processed for improved visual image
10.3.8.2 Radioscopic systems wherein the radiation source analysis or automatic, computer-aided analysis, or both. Long-
and detection system are manipulated instead of, or in addition term records may be obtained through storing the images on a
to, the article under test will entail the use of more stringent CD or DVD.
shielding requirements. 10.4.2.4 Since there are many methods for real-time and
10.3.9 Physical Reference Standards: near real-time detection of radiation with digital detector
10.3.9.1 Penetrameters (IQIs)Radiographic sensitivity as arrays, there are a number of possible systems. DR systems are
indicated by the conventional IQI measures contrast and, to a conveniently classified into two main categories: (1) those
limited degree, resolution. Since most radioscopic systems are based on conversion of X-rays into light using scintillators, (2)
resolution limited, however, a greater emphasis is placed on those based on conversion of X-rays into electrons using
IQIs that measure resolution (such as wire mesh or a line pair semiconductors junctions (direct conversion).
test pattern). 10.4.3 Advantages and ApplicationsDR systems are pre-
10.3.9.2 Use of a Reference BlockSee 10.2.10.3 for a ferred when information about the three-dimensional distribu-
description of the reference block. The reference block should tion of imperfections, defects, and discontinuities within a
be placed into the radioscopic system in the same position as composite material or component is needed.

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
31
Downloaded/printed by
E2533 09
10.4.3.1 DR systems provide a rapid check of dimensions 10.4.7.1 A general discussion about radiological safety and
and the internal configuration within composite materials and hazards and applicable Federal and NCRP documents are given
components. in section 10.2.8 (Radiography and Computed Radiology).
10.4.3.2 DR systems have advantages over radiography for 10.4.7.2 DR systems wherein the radiation source and
characterization of nonsymmetrical articles under test because detection system are manipulated instead of, or in addition to,
of the three-dimensional capability when using mechanical the article under test will entail the use of more stringent
motion of the articles under test. shielding requirements.
10.4.3.3 DR systems provide a much better contrast resolu- 10.4.8 Calibration and Standardization:
tion than radioscopy systems. Using the integration function- 10.4.8.1 Reference StandardsReference radiographs pro-
ality of the PC software very high Signal to Noise Ratios duced by ASTM and acceptance standards written by other
(>>1000) are possible and with this high SNR the contrast organizations may be employed for DR examination as well as
for radiography, provided appropriate adjustments are made to
sensitivity can be better than 0.5 %. This obtains sufficient
accommodate for the differences in the fluoroscopic images.
contrast between low atomic number composite substructures
10.4.8.2 Image Quality ConsiderationsImage quality is
(for example, matrix, fiber, laminae). No use of radiopaque
governed by three factors, image contrast, image resolution and
materials or contrast agents may be necessary.
contrast to noise ratio (CNR). A number of different ap-
10.4.3.4 DR systems can offer a high geometrical resolution proaches to assessing image quality are discussed in Section 11
with: (1) a small pixel size (50 m), (2) a micro focus tube and of Guide E1000, and also in Practices E2445, E2446, and
larger magnification. Combinations are possible. E2597.
10.4.3.5 The screens and the front cover of a detector from 10.4.8.3 Use of Duplex Wire IQI and Duplex Step
a DR system can be adapted to very low energies. This leads to WedgeA duplex wire IQI and a step wedge with grooves on
a high sensitivity at low energies, for example, 20 keV. The low any step may be used, if so desired, to determine and track DR
energy reduces the scatter radiation of the composite material system performance in terms of spatial resolution, contrast
in the beam. sensitivity, SNR, dynamic range and image LAG behavior. The
10.4.4 Limitations and InterferencesDR systems require duplex wire IQI is used without an additional absorber to
careful alignment of the source, article under test, and detector. evaluate detector spatial resolution. The grooved step wedge is
As DR systems have a larger tolerance to the dose than used to evaluate system contrast sensitivity, the SNR and the
radioscopic systems the alignment must not be as perfect as dynamic range. The image lag can be measured by capturing a
with radioscopic systems. sequence of images in which the source is cut off.
10.4.4.1 Radiation handling requirements and composite 10.4.8.4 Equipment QualificationA listing of the system
article positioning devices peculiar to dynamic systems usually features that must be qualified to ensure that the system is
result in greater capital equipment costs than in conventional capable of performing the desired examination task. Addition-
static radiography. ally, DR system qualification can best be evaluated with IQIs
similar to the imperfection or discontinuity type being exam-
10.4.4.2 DR systems need a computer system to be oper-
ined.
ated. The operator should be familiar with X-ray technology
10.4.9 Physical Reference Standards:
and additional with the use of a computer system.
10.4.9.1 Penetrameters (IQIs)Radiographic sensitivity as
10.4.4.3 The very high SNR of a DR system is possible only indicated by the conventional IQI measures contrast and, to a
with a careful calibrated detector. The calibration process limited degree, resolution. With DR systems both parameters
needs some dedicated know how of the operator. are very different with different types of detectors. Both
10.4.5 Use of Referenced Documents: parameters should be measured independent from each other.
10.4.5.1 Consult Practice E2597 for comparison of Digital 10.4.9.2 Use of a Reference BlockSee 10.2.10.3 for a
Detector Arrays (DDAs) so that an appropriate DDA is selected description of the reference block. The reference block should
to meet NDT requirements, using a common set of technical be placed into the DR system in the same position as the actual
measurements; namely, basic spatial resolution, efficiency, article under test and may be manipulated through the same
achievable contrast sensitivity, specific material thickness range of motions through a given exposure for dynamic DR
range, image lag, burn-in, bad pixels and internal scatter systems as are available for the actual object so as to maximize
radiation. the DR examination systems response to simulated imperfec-
10.4.6 Geometry and Size Considerations: tions.
10.4.6.1 DR systems are well suited for characterization of 11. Shearography
nonsymmetrical articles under test because of the three- 11.1 Referenced Documents
dimensional capability when using mechanical motion of the 11.1.1 ASTM Standards:2
article relative to the X-ray beam. E2581 Practice for Shearography of Polymer Matrix Com-
10.4.6.2 Considerations about test geometry (relative place- posites, Sandwich Core Materials and Filament-Wound Pres-
ment of source, article under test, and imaging devices), sure Vessels in Aerospace Applications
thickness of the article being tested, and observable defect F1364 Practice for Use of a Calibrated Device to Demon-
sizes are covered in 10.2.7 (Radiography). strate the Inspection Capability of an Interferometric Laser
10.4.7 Safety and Hazards: Imaging Nondestructive Tire Inspection System

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
32
Downloaded/printed by
E2533 09
TABLE 11 Summary of Shearography
What Is Seen
Applications How It Works Advantages Limitations
and Reported?
Whole field, noncontact, Shearography is an Sensitive to out-of-plane Surface condition, Imperfection or
real-time detection of interferometric method that micron to submicron level especially glossiness, can discontinuity-induced out-
disbonds, delaminations, requiring application of a deformations. interfere or prevent of-plane deformation is
cracks, impact damage, small proof load to an accurate shearographic typically displayed as
modulus changes. article under test between Can perform large area detection, thus requiring interference fringes on a
the initial and final image inspections. the use of surface dulling monitor. System output
High-speed, cost effective capture. By subtracting or agents (exception: thermal images show qualitatively
inspection technique for superimposing images of Less sensitive to the image shearography). pictures of structural
quality assurance, material the composite article taken degrading effect of features and surface and
optimization, and in the unloaded and loaded environmental vibration Additional equipment is subsurface anomalies as
manufacturing process states, detection of compared to other required to determine well as quantitative data
control. localized strain interferometric techniques. surface derivative slope such as defect size, area,
concentrations caused by changes, and thus use the depth, material deformation
May be built as portable subsurface imperfections Operating equipment method as a quantitative vs. load change and
units or into gantry or discontinuities is requires less technical tool. material properties.
systems for scanning large possible. understanding. Quantitative measurements
structures. are based on point-to-point
No film material is changes in the surface
Can be used to measure consumed. slope, ]w/ ]x.
the deformation response
of a structure to an applied Can be automated for
load. production environments.

Robust construction for


industrial use.

High-speed throughputs in
the range of 10 to 50 m2/h
(~100 to 500 ft2/h) are
possible.

11.1.2 Federal Standards:12 respect to a second image of the part. The amount of image
21 CFR 1040.10 Laser Products shear can be represented as a vector quantity with an associated
21 CFR 1040.11 Specific Purpose Laser Products angle and displacement. The shear vector, among other factors,
11.1.3 LIA Document:13 determines the sensitivity of the interferometer to surface
ANSI, Z136.1-2000, Safe Use of Lasers displacement derivatives, ]w/ ]x. The two sheared images of
11.1.4 BSI Document:14 the test image are focused onto the CCD camera (Fig. 3). Light
EN 60825-1 Safety of Laser ProductsPart 1: Equipment from pairs of points in each sheared image interfere with each
Classification, Requirements and Users Guide other, causing interference at every paired point across the field
11.2 General Procedure of view. A phase shift mirror in the Michelson interferometer
11.2.1 Shearography NDT systems use a common path may be phase stepped using a piezoelectric device and the
Michelson-type interferometer to image the first derivative of images combined to create a phase map. Further processing
the out-of-plane deformation of the article under test surface in
response to a change in load. Loads can be thermal, pressure,
or vacuum stresses, or acoustic or ultrasonic vibrations. Care is
take to ensure that the magnitude of the applied load is far
below the damage threshold of a given article under test. The
optimum load type and magnitude depend on the imperfection
or discontinuity type and depth and is best determined before
serial testing by making trial measurements. The Shearography
NDT procedure consists illuminating an article under test with
fixed frequency laser light before and after a small proof load
is applied. A mirror (the tilt mirror) is precisely tilted to induce
an offset, or sheared image, of the article under test with

12
Published by the Center for Devices and Radiological Health (CDRH) of the
Food and Drug Administration (FDA), available from Government Printing Office
Superintendent of Documents, 732 N. Capitol St., NW, Mail Stop: SDE, Washing-
ton, DC 20401.
13
Available from the Laser Institute of America, 13501 Ingenuity Drive, Suite
128, Orlando, FL 32826. FIG. 3 Schematic Diagram of an Interferometer and Machined
14
Available from the British Standards Institute, 389 Chiswick High Road, Test Plate (Reference Standard) Consisting of a Plate with a Flat-
London, W4 4AL, United Kingdom. Bottom Hole

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
33
Downloaded/printed by
E2533 09
using any number of unwrapping algorithms may be used to These include: teach/learn part scan programming, electronic
generate fringe free images of local surface deformation imaging of entire articles under test, image analysis and defect
derivates. Each video frame, comprised of the complex addi- measurement tools, and automated operation.
tion of these two sheared images can be subtracted from a 11.3.5 Advantages and ApplicationsLaser Shearography
stored reference image. Loaded articles under test will show has shown to be an effective inspection method, fast and
out-of-plane deformation (strain concentration) near imperfec- accurate defect location and sizing. It is a noncontact inspec-
tions or discontinuities that is significantly greater than the tion method which lends itself to in process inspection of
out-of-plane deformation produced in imperfection or composites. Surface deformations as small as 23 nanometers
discontinuity-free areas. These areas containing imperfections can be detected and quantitatively measured using Laser
or discontinuities are indicated by the presence of interference Shearography. Some specific applications include:
fringes (Fig. 4). 11.3.5.1 Portable SystemsCan be used to identify repair
11.3 Significance and Use areas in composite laminates, such as those with far side,
11.3.1 Shearography systems may be built as portable units bonded stringers (diagonal linear features).
or into gantry systems, similar to UT C-Scan systems, for 11.3.6 Pressure ShearographyPressure shearography has
scanning large structures. shown to be an effective inspection method for filament-wound
11.3.2 Changes in the applied load required to reveal pressure vessels constructed from aluminum or non-corrosive
subsurface anomalies frequently induce gross deformation or steel liners housing liquid fuel or chemicals, for example.
rotation of the article under test. Pressurization of these vessels increases the hoop and longitu-
11.3.3 Laser interferometric imaging techniques such as dinal strain on the vessel surface. The z-axis component of
shearography have seen dramatic performance improvements strain concentrations are detected, allowing the liner-to-
in the last decade and wide acceptance in industry as a means composite bond integrity to be evaluated.
for high-speed, cost effective inspection and manufacturing 11.3.7 Thermal ShearographyUnlike thermography,
process control. These performance gains have been made which is sensitive to changes in surface temperature (or the
possible by the development of the personal computer, high derivatives of the temperature change), thermal shearography
resolution CCD and digital video cameras, high performance is sensitive to changes in the thermal expansion of a structure.
solid-state lasers and the development of phase stepping Since impact damage (in carbon and Kevlar fiber wound
algorithms. System output images show qualitatively pictures pressure vessels, for example), disbonds, foreign object debris,
of structural features and surface and subsurface anomalies as and delaminations all produce local changes in the coefficient
well as quantitative data such as defect size, area, depth, and of thermal expansion, such defects can be detected by this
changes in deformation as a function of load and material method.
properties.
11.3.7.1 Vacuum ShearographyThe technique has been
11.3.4 Gantry mounted production shearography systems
successfully used to detect discontinuities such as local delami-
share many operational features with UT C-scan systems.
nation in composite helicopter blades during production. For
example, production shearography systems can be placed on a
gantry inside a vacuum test chamber that simulates pressure
cycling between ambient pressure and 2 kPa (0.3 psi).
11.3.7.2 Acoustic ShearographyThis technique is used to
image disbonds and voids during Spray-On-Foam-Inspection
(SOFI) on rocket launch vehicles requiring extensive thermal
protection systems to prevent damage from combustion flame,
frictional aerodynamic heating during flight in the atmosphere,
and loss of cryogenic propellants.
11.3.7.3 Ultrasonic HolographyThis technique has been
used to inspect Feltmetal and plasma-sprayed aircraft abrad-
able seals (inspection standard since 1982). It combines time-
averaged holography with a low frequency ultrasonic vibration
applied to the compressor shroud. Holography provided excel-
lent disbond detection with easily interpreted images essen-
tially identical to UT results, but not affected by part geometry
or material thickness changes. Early systems used film holog-
raphy with a one step chemical process, which produced
production quality holograms in approximately 10 seconds.
The results were viewed on a video monitor. Electronic
holography currently using mega-pixel CCD cameras has
NOTEThe shearogram shows the positive (white) and negative (black) radically improved system operation speed and reliability.
slope change indicating a 7-micron out-of-plane deformation.
FIG. 4 A Phase Map Shearogram of a Reference Standard
11.3.8 Limitations and InterferencesThe shine condition
Consisting of a Plate with a Flat-Bottom Hole Using a Horizontal of a surface, like dark glossy surface can deflect the laser
Shear Vector speckle pattern and a coating to dull the surface may be

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
34
Downloaded/printed by
E2533 09
required. (Thermal shearography is not generally affected by operation. When using Class 3a laser systems, care must be
variations in emissivity or paint on the test part surface.) taken not to view the laser emissions with any optical system
11.4 Use of Referenced Documents that will increase concentration of the laser light (that is,
11.4.1 Consult Practice F1364 for a description of the binoculars or telescopes). This does not include normal cor-
construction and use of a straining block device that can be rective lenses.
used to calibrate the anomaly detection capability of shearog- 11.6.3 Class 3b and Class 4 laser systems should generally
raphy systems. be avoided for all but laboratory systems due to required
11.4.2 Consult Practice E2581 for a description of shearog- operating restrictions and the need for additional medical
raphy procedures of polymer matrix composites, sandwich surveillance.
core materials, and filament-wound pressure vessels. 11.7 Calibration and Standardization
11.5 Geometry and Size Considerations 11.7.1 Precision calibration of the shearogram image scale
11.5.1 Depending on the object size, laser diodes, gas lasers, (pixels/inch) and the shear vector allow further processing of
and solid-state lasers are used as light sources. shearography data to determine defect indication dimensions,
area and the deformation of the material. The digital measure-
11.5.2 Shearography results are not affected as much by part
ment of the deformation derivative may be integrated to show
geometry or thickness changes compared to other NDT tech-
the shape of the target surface deformation as well as the
niques such as UT.
magnitude of the deformation at any location.
11.5.3 Shearography cameras can be positioned on multi- 11.8 Physical Reference Standards
axis positioning systems to enable whole field characterization 11.8.1 Straining BlocksStraining blocks as described in
of articles under test with complex shapes (cones, cylinder) and Practice F1364 are designed to create an image of a known
features (edges, flanges). anomaly against which the performance of the shearography
11.6 Safety and Hazards system may be evaluated. The block is constructed by securing
11.6.1 Laser SafetyShearography uses laser light to illu- a deformable membrane over a rigid block that contains a
minate the surface of the article under test. A laser is simply a series of holes of various sizes and shapes. The membrane
convenient source of monochromatic and coherent light that should be made of a material that retains its physical properties
makes the implementation of Shearography possible. With the over time with minimal aging effects. Interior holes in the
exception of extremely low powered laser systems, virtually all block are either vented to atmospheric pressure or sealed at
laser products pose some form of hazard; most often associated nominal pressure, allowing differential pressure to exist in the
with the direct exposure of the eyes and skin to the laser light. membrane when the block is subjected to vacuum. It is the
Laser systems are classified in the United States in accordance deflection of the membrane under this differential pressure that
with the Center for Devices and Radiological Health (CDRH) is measured by the shearography system. By studying the
division of the Food and Drug Administration (FDA). The presence and clarity of fringe pattern obtained from straining
applicable federal documents are 21 CFR 1040.10 and 21 CFR blocks, adjustments such as optical alignment, laser power,
1040.11. In the European community, laser system standards stressing (vacuum) level, beam ratio modifications, etc., can be
are overseen primarily by the International Electrotechnical made, thus ensuring optimal system performance. Detailed
Commission (IEC) and the British Standards Institution (BSI). instructions on how to fabricate straining blocks can be
The applicable European document is EN 60825-1. Additional obtained from ASTM.4
Federal, State, and Local regulations may also apply to the use
and classification of laser products depending on the intended 12. Strain Measurement (Bonded Strain Gauges)
location of the system. Many of these regulations are based on 12.1 Referenced Documents
classification data provided by the American National Stan- 12.1.1 ASTM Standards:2
dards Institute (ANSI). ANSI, Z136.1-2000 provides detailed E251 Test Methods for Performance Characteristics of Me-
information regarding Hazard Evaluation and Classification, tallic Bonded Resistance Strain Gauges
Control Measures, Laser Safety Programs and Employee E1237 Guide for Installing Bonded Resistance Strain
Training, Medical Surveillance, Non-beam Hazards, Criteria Gauges
for Exposure of Eye and Skin, and Small and Extended Source 12.2 General Procedure
Measurements. From a practical standpoint, laser shearography 12.2.1 Bonded strain gauge consist of a grid of very fine
systems should be classified so as to provide the most usable metallic wire, foil, or semiconductor material bonded to the
system for the operator with the least restrictions. To minimize strained surface or carrier matrix by a thin insulated layer of
hazard and restrictions, systems with classification of Class 1, epoxy (Fig. 5). When the carrier matrix is strained, the strain is
2, and 3a (3r IEC) are the preferred classifications for shearog- transmitted to the grid material through the adhesive. The
raphy systems. variations in the electrical resistance of the grid are measured
11.6.2 Systems classified as classified as Class 1 and 2 laser as an indication of strain. The grid shape is designed to provide
systems generally do not require any special safety consider- maximum gauge resistance while keeping both the length and
ation beyond a basic understanding of the safe use of lasers. width of the gauge to a minimum. In bonding strain gauge
Under normal working conditions, Class 3a laser systems elements to a strained surface, it is important that the gauge
extend allowable output emissions of the laser system by 5 experience the same strain as the object. With an adhesive
times those of Class 2 laser systems without adding additional material inserted between the sensors and the strained surface,
restrictions beyond a more in depth knowledge of safe laser the installation is sensitive to creep due to degradation of the

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
35
Downloaded/printed by
E2533 09
TABLE 12 Summary of Strain Measurement (Bonded Strain Gauges)
What Is Seen
Applications How It Works Advantages Limitations
and Reported?
Can be used to measure Metallic bonded resistance Relatively inexpensive. Individual strain gauges The output of a resistance
both static and dynamic strain gauges consist of a cannot be calibrated. measuring circuit (for
strain. grid of wire filament or Less bulky and better example, a Wheatstone
metal foil (a resistor) resolution than Response to strain is low. bridge) is expressed in
Strain measurement at bonded directly to the extensometers. millivolts output per volt
cryogenic to very high strained surface by a thin The low level of the signal input. Since a very low
temperatures is possible. layer of epoxy resin. When Highly sensitive and can makes strain gauges voltage output signal is
a load is applied to the achieve overall accuracy of susceptible to unwanted generated, sensitivity of
In applications where surface, the resulting better than 6 0.10% strain. noise from other electrical 100 microvolts or better is
higher unit resistance and change in surface length is devices, thus necessitating required.
sensitivity (higher gauge communicated to the Have small physical size shielding or guarding.
factor) are needed, resistor and the and low mass.
semiconductor wafer corresponding strain is Strain gauges
sensors are preferred. measured in terms of the Available in a variety of measurement is subject to
electrical resistance of the gauge lengths (0.2 to 100 numerous potential
In applications where less wire or foil which varies mm (0.008 to 4 in.)). sources of error such as:
sensitivity to temperature linearly with strain. The
variations and lower drift metal grid and adhesive Expansion or contraction of
are needed, metallic bonding agent must work the strain-gauge element
bonded strain gauges are together in transmitting the and/or the base material.
preferred. strain, while the adhesive
must also serve as an Change in the resistivity or
In applications where electrical insulator between in the temperature
stable installation, less the grid and the composite coefficient of resistance
drift, and elimination of articles surface. due to temperature or
errors due to creep and aging leading to apparent
hysteresis are needed, Semiconductor strain strain or drift, respectively.
thin-film and diffused gauges, consisting of a
semiconductor strain wafer with the resistance Hysteresis and creep
gauges are preferred. element diffused into a caused by imperfect
substrate, measure bonding.
Arrays of strain gauges piezoresistive changes in
can be used to completely the silicon or germanium Nonlinear resistance-to-
characterize axial (tensile as a function of stress as strain relationships for
and compressive) strain, opposed to strain. The semiconductor strain
as well as shearing, gauge is bonded directly to gauges.
Poisson, bending, and the strained surface by a
torsional strains. thin layer of epoxy resin.

Thin-film and diffused


semiconductor strain
gauges are permanently
attached to the test
surface, obviating the need
for adhesive bonding.

bond, temperature influences, and hysteresis caused by ther- ture compensation is automatic, as resistance change due to
moelastic strain. Because many glues and epoxy resins are temperature variations will be the same for all arms of the
prone to creep, it is important to use resins designed specifi- bridge.
cally for strain gauges. The three primary considerations in 12.3 Significance and Use
gauge selection are: operating temperature, the nature of the 12.3.1 Strain gauges are part of a complex system that
strain to be detected, and stability requirements. In addition, includes the article under test, adhesive, gauge, lead-wires,
selecting the right carrier material, grid alloy, adhesive, and instrumentation, and (often) environmental protection.
protective coating will guarantee the success of the application. 12.3.2 Properly designed and manufactured strain gauges,
In order to measure strain with a bonded resistance strain whose properties have been accurately determined and with
gauge, it must be connected to an electric circuit that is capable appropriate uncertainties applied, represent powerful measure-
of measuring the minute changes in resistance corresponding to ment tools. Strain gauges are very sensitive devices with
strain. Strain gauge transducers often employ four strain gauge essentially infinite resolution. The performance parameters
elements electrically connected to form a Wheatstone bridge discussed in Test Methods E251 must be known to an accept-
circuit. The number of active strain gauges that should be able accuracy to obtain meaningful results in field applications.
connected to the bridge depends on the application. For 12.3.3 Bonded resistance strain gauges differ from exten-
example, it may be useful to connect gauges that are on someters in that they measure average unit elongation (DL/L)
opposite sides of the article under test, one in compression and over a nominal gauge length rather than total elongation
the other in tension. In this arrangement, one can effectively between definite gauge points.
double the bridge output for the same strain. In installations 12.3.4 Strain gauges are the most widely used devices for
where all of the arms are connected to strain gauges, tempera- determining stress in structures. Since the testing is often

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
36
Downloaded/printed by
E2533 09

FIG. 5 Schematic of a Typical Metal-Foil Strain Gauge

destructive, strain gauges cannot be reused. However, strain and diffused semiconductor strain gauges, this guide empha-
gauge performance is affected by both the materials they are sizes the use of metallic bonded resistance strain gauges. Some
made from and their geometric design. of the advantages and disadvantages of these newer types of
12.3.5 To be used, strain gauges must be bonded to a strain gauges compared to metallic bonded resistance strain
structure. Optimum and reproducible detection of surface gauges are summarized in Table 13.
deformation depends heavily on the materials used to clean the
bonding surface, to bond the gauge, and to provide a protective NOTE 13Strain can also be measured using non-contact methods
coating. Skill of the installer is another major factor in success using optical extensometers (video cameras). However, care has to be
taken in verifying the resolution of the optical method.
since consistent surface preparation, mounting procedures, and
verification techniques are paramount. Specific factors that 12.3.9 Advantages and Applications:
may affect strain gauge performance include resistive element 12.3.9.1 Properly designed and manufactured strain gauges
alloy, carrier material, gauge length, gauge and resistive are very sensitive devices with essentially infinite resolution.
element pattern, solder tap type and configuration, temperature They can determine small dimensional changes in structures
compensation characteristics, resistance of active elements, with excellent accuracy, far beyond that of other known
and gauge factor. devices.
12.3.6 Finally, instrumentation systems must be carefully
12.3.10 Limitations and Interferences:
designed to ensure that they do not unduly degrade the
performance of the gauges. In many cases, it is impossible to 12.3.10.1 Response to strain, however, is low and great care
achieve this goal. If so, allowance must be made when must be exercised in their use. Furthermore, to ensure strain
considering the accuracy of data. gauge test data are within a defined accuracy, the gauges must
12.3.7 Test conditions can, and some instances, be so severe be properly bonded and protested with acceptable materials. It
that error signals from strain gauges systems far exceed those is normally simple to ascertain that strain gauges are not
from the structural deformations being measured. Great care performing properly. The most common symptom is instability
must be exercised in documenting magnitudes of error signals with time or temperature change. If strain gauges do not return
so that realistic values can be placed on associated uncertain- to their zero reading when the original conditions are repeated,
ties. or there is low or changing resistance to ground, the installation
12.3.8 Although newer types of strain gauges are available; is suspect.
namely, semiconductor strain gauges, thin-film strain gauges, 12.4 Use of Current Standard Documents

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
37
Downloaded/printed by
E2533 09
TABLE 13 Comparison of Newer Types of Strain Gauges with the error and estimating the accuracy of the measurements
Metallic Bonded Resistance Strain Gauges when applying non-contacting methods to the study of events
Strain Gauge for which the optical integration time is much smaller than the
Advantages Disadvantages
Type
inverse of the maximum temporal frequency in the encoded
Semiconductor Smaller. Greater sensitivity to data (that is, events that can be regarded as static during the
Less expensive. temperature variations.
Higher unit resistances. Tendency to drift. integration time). A brief application of the approach, along
Resistance-to-strain with specific examples defining the various terms, is given in
relationship is nonlinear.
the Appendix.
Thin-Film Eliminates the need for Fabrication involves 12.5 Geometric and Size Considerations
adhesive bonding. vacuum deposition or 12.5.1 Large composites structures such as filament-wound
Installations are much sputtering techniques
more stable (resistance (installation is permanent).
pressure vessels which make use of conventional extensom-
values experience less eters impractical are ideally suited for measurements using
drift). strain gauges.
Stressed force detector
can be a metallic
12.6 Safety and Hazards
diaphragm or beam with a 12.6.1 During specimen surface cleaning, gauge bonding,
deposited layer of ceramic and protection steps or strain gauge installation, hazardous
insulation.
chemicals may be used. Users are responsible for contacting
Diffused Eliminates the need for Greater sensitivity to the manufacturers of these chemicals for applicable Material
Semiconductor adhesive bonding. ambient temperature Safety Data Sheets and to adhere to the required precautions.
Smaller. variations (limited to
Less expensive. moderate-temperature 12.7 Calibration and Standardization
Accurate and repeatable. applications). 12.7.1 Data Reduction and StatisticsSince strain gauges
Provide a wide pressure Measurement often used to determine values of performance characteristics are
range. requires temperature
Generate a strong output compensation. generally not reusable, the data obtained from a sample of such
signal. Fabrication involves a gauges are used to predict the performance for all other gauges
Errors due to creep and photolithographic masking
hysteresis eliminated. technique (installation is
in the same batch. Well established statistical methods, for
permanent). example t-tests, are used to make predictions about the
uncertainty in the data from an individual gauge. These
methods require that tests be made upon a sample taken at
random from the batch, and generally assume the test results
12.4.1 Consult Test Methods E251 for determination of will have a normal, that is, Gaussian, distribution. For verifi-
strain gauge performance characteristics. Suggested testing cation of the values and tolerance furnished for a shipment of
equipment designs are included. Methods for determining five strain gauges, the reader is referred to Appendix X3 of Test
strain gauge parameters are discussed: (1) Resistance at a Methods E251.
Reference Temperature, (2) Gauge Factor at a Reference 12.7.2 Verification ChecksThe completed strain gauge
Temperature, (3) Temperature Coefficient of Gauge Factor, (4) installation shall be checked prior to use to verify its integrity
Transverse Sensitivity, and (5) Thermal Output. These test and ability to provide reliable and repeatable data. Two checks
methods do not apply to transducers, such as load cells and are possible: (1) initial checks after installation, and (2) checks
extensometers, that use bonded resistance strain gauges as after lead-wire connections have been made.
sensing elements. 12.8 Physical Reference Standards
12.4.2 Consult Guide E1237 for guidance on strain gauge 12.8.1 It is important to realize that individual strain gauges
installation and verification. This document is not intended to cannot be calibrated. If calibration and traceability to a
be used for bulk or diffused semiconductor gauges. This physical reference standard are required, strain gauges should
document pertains only to adhesively bonded resistance strain not be used.
gauges. Detailed descriptions are provided for gauge selection,
bonding technique selection, surface preparation, gauge instal- 13. Infrared Thermography (Non-Contact Methods
lation (general consideration and consideration about the Using Infrared Camera)
adhesive used), lead wire connection, verification checks, and 13.1 Referenced Documents
protective coatings. 13.1.1 ASTM Standards:2
12.4.3 Consult Guide E2208 for assistance in understanding E1213 Test Method for Minimum Resolvable Temperature
the issues related to the accuracy of non-contacting strain Difference for Thermal Imaging Systems
measurement systems (for example, Moire Interferometry) and E1311 Test Method for Minimum Detectable Temperature
for a common framework for quantitative comparison of Difference for Thermal Imaging Systems
optical systems. The output from a non-contacting optical E1543 Test Method for Noise Equivalent Temperature Dif-
strain and deformation measurement system is generally di- ference of Thermal Imaging Systems
vided into optical data and image analysis data. Optical data E1862 Test Methods for Measuring and Compensating for
contains information related to specimen strains and the image Reflected Temperature Using Infrared Imaging Radiometers
analysis process converts the encoded optical information into E1897 Test Methods for Measuring and Compensating for
strain data. Guide E2208 describes potential sources of error in Transmittance of an Attenuating Medium Using Infrared Im-
the strain data and describes general methods for quantifying aging Radiometers

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
38
Downloaded/printed by
E2533 09
TABLE 14 Summary of Infrared Thermography (Non-Contact Methods Using Infrared Camera)
What Is Seen
Applications How It Works Advantages Limitations
and Reported?
Can be used to detect An infrared video camera Relatively fast because it is The infrared camera The infrared camera
delaminations, debonds, views the surface an area inspection method. requires a direct view of presents a video image of
voids, cracks, inclusions, temperature distribution In some cases, inspection the article under test the article under tests
and occlusions, especially across the surface of the details are comparable to surface, and clearance is surface temperature
in thinner laminates. article under test either X-ray or ultrasonic required for focusing. distribution. A60 Hz frame
Thickness limit depends on during or shortly following methods at a fraction rate is common, but other
the thermal diffusivity of the heating (or cooling) the (typically 20%) of the Non-uniform application of frame rates are available.
composite material and on area of interest. inspection time. heating or cooling can Some cameras provide an
the equipment and Subsurface discontinuities result in confusing analog video output for
technique employed. affect the heat flow, Inspection can be thermographic images. recording and/or digital
resulting in localized completely non-contacting. input/output for interfacing
Well-suited for rapid temperature variations at Heating equipment may be to a computer.
scanning of large surface the surface. Does not require access to unsafe to operate in fuel-
areas. Suspect areas may the opposite side of the rich environments. Defect areas appear as
be identified for more Thermal diffusion is the structure. variations in the surface
thorough evaluation. mechanism by which The surface contrast temperature viewed by the
internal defects are located Provides supplemental temperature due to an infrared camera. These
Best suited for high in an article under test. It is information to other NDI internal defect drops temperature variations are
emissivity (low reflectivity) a material property defined methods. exponentially with its mapped to color or grey-
surfaces. A flat-black as the ratio of its thermal depth, generally limiting scale pallets for
surface provides optimum conductivity and heat No harmful radiation is usage to thinner laminates presentation.
results, but most dull capacity. Changes in the emitted, and surface (under 13 inch thick in most
surfaces work well. rate of heat flow due to heating requirements are cases). Images of internal defects
subsurface discontinuities generally small (no more are transitory. The
Can be configured for affect the observed surface then 5 to 10C). Not effective on low appearance time, peak
either single-sided or two- temperature distribution. emissivity surfaces unless contrast image, and
sided inspection. Great versatility of a high emissivity coating is subsequent fading
Thermal diffusion can be applications. Can be used applied (such as a flat depends on the article
initiated by heating on a wide variety of black tempera paint). under tests thermal
(radiation, convection, or thermally conductive properties and those of the
conduction), or cooling materials. defect, and also on the
(convection or conduction), size and depth of the
or mechanical (vibration). defect. In some cases, the
contrast temperature is
very weak and/or short
lived. Image storage and/or
additional data processing
may be required.

E1933 Test Methods for Measuring and Compensating for cause thermal diffusion in the article under test is commonly
Emissivity Using Infrared Imaging Radiometers known as the active method. External heating is most com-
E1934 Guide for Examining Electrical and Mechanical monly used, although cooling (removal of heat) can be equally
Equipment with Infrared Thermography effective. Heating may be conductive (such as a heat blanket),
E2582 Practice for Infrared Flash Thermography of Com- convective (such as a heat gun), or radiation (using flash or
posite Panels and Repair Patches Used in Aerospace Applica- flood lamps). Cooling may be conductive (such as an ice pack)
tions or convective (such as a vortex gun). For some defect types
13.1.2 Military Handbooks and Standard:6 (such as tightly closed cracks) a mechanical stimulation
MIL-HDBK-731 Nondestructive Testing Methods of Com- (vibration) provides better detection. The intent of mechanical
posite MaterialsThermography stimulation is to cause the defect area to generate heat by
13.2 General Procedure friction or by cyclic stress loading. Infrared cameras vary
13.2.1 Thermal diffusion (heat flow) is initiated in the article considerably in features and performance. In general, best
under test while the evolving surface temperature is viewed results are achieved with higher sensitivity cameras having
with an infrared video camera. Defects, nonhomogeneities, or cooled detectors, but these are more expensive and less
other undesirable conditions in the article under test will portable than their uncooled counterparts.
evidence themselves as local hot or cold spots in the thermo- 13.3 Significance and Use
graphic image. The local temperature variations are transient 13.3.1 Infrared Thermography inspection equipment can be
images, meaning that they will appear, peak, and subsequently very simple (a hand-held infrared camera and a heat gun) to
fade away over time as the temperature of the article under test very complex (a fully integrated computer-controlled system).
re-stabilizes. The evolving surface temperature distribution is What is required depends on the application. Considerations
governed by thermal diffusion in the interior of the article include:
under test, the depth of the feature of interest, and its 13.3.1.1 Defect properties (diffusivity, size, depth),
cross-sectional area. It is important to note that you cannot 13.3.1.2 Infrared camera capabilities (sensitivity, band-
obtain any information about the interior of an article under test width, frame rate, etc.),
that is in thermal equilibrium. Using an external stimulus to 13.3.1.3 Data capture and storage, and

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
39
Downloaded/printed by
E2533 09
13.3.1.4 Accuracy and repeatability. (1) placing the article under test in contact with an object at a
13.3.2 Typical defect types generally detectable with infra- different temperature (thermal conduction), or (2) flowing air
red thermography include voids, inclusions, cracks, delamina- or fluid across the article under test surface (convection
tions, and the presence of fluids. Potential applications include heating), or by exposing the article under test to a flood lamp
monitoring/control of manufacturing processes, quality assur- or flash lamp (radiation heating). Cooling is equally effective,
ance of newly manufactured parts, and inspection of assem- but only conductive and convective transfer is available.
blies for various types of damage. The smallest observable Another form of external stimulation is by cyclic mechanical
defect size is limited by the distance between the camera and deformation of the article under test. Examples are (1) body
the part surface and by the instantaneous field of view (IFOV) resonance, or (2) local resonance using an ultrasonic trans-
of the camera. The contrast temperature appearing on the ducer. In general, cyclic frequencies between 5 and 30 hertz are
surface falls off exponentially with the depth of the defect common for composite materials.
(1/[depth]3) and may also negatively impacted by heat flowing 13.3.6.1 Noncontact MethodsRadiant energy requires no
around the defect area (small defects). As a rule of thumb, medium to transfer heat from the source to the surface of the
the smallest observable defect in ideal conditions is equal or article under test. Heat lamps (flash or flood lamps) are
greater than its depth. Therefore, a 14-in. diameter void in a commonly used in non-contact heating. Additionally, forced air
composite laminate will generally not be observable at a depth heating (or cooling) is usually considered non-contacting
greater than 14 inch. (convection heating/cooling). It is usually easier to obtain a
13.3.3 In general, contrast temperatures caused by the uniform thermal emission pattern over a relatively large area
presence of defects on composite materials are very small. using radiant heating. Radiant heating methods are also well
Most infrared cameras are designed to have a measurement suited for articles under test that have irregular shape or
range of a few hundred degrees Fahrenheit. For materials imperfect surface. Heat emission patterns acquired from radi-
inspection, the contrast temperature is typically no greater than ant heating are generally more reproducible and amenable to
a few tenths of a degree, and is often much smaller, therefore quantitative interpretation than those acquired by convective
the infrared cameras are often operated near their detection heating.
limits. There are a wide variety of infrared cameras available 13.3.7 Limitations and InterferencesEffectiveness of In-
today. It is very important to evaluate the infrared camera on a frared Thermography inspection techniques depends on many
representative article under test having known defects that are factors, which are summarized in the following paragraphs.
similar to what needs to be found in practice. Cameras with 13.3.7.1 Orientation of an imperfection or discontinuity
cooled detectors are more sensitive and less noisy than their relative to the principle direction of heat flow.
uncooled counterparts, generally resulting in easier detection 13.3.7.2 Depth of the imperfection or discontinuity from the
of subsurface features. Newer infrared cameras typically have viewed surface, and size of the imperfection or discontinuity
focal plane array detectors, whereas older cameras have a relative to its depth.
single detector and a pair of mechanically rotated prisms to 13.3.7.3 The reflection of incident radiant energy at the
create a scanned infrared image. Different spectral ranges are surface of the article under test (assuming it has a reflective
available, approximately 35 micron (short-wave) and ap- surface) due to heat lamp reflection or nearby hot objects can
proximately 711 micron (mid-band/long wave). Many infra- interfere with attempts to interpret the heat emission pattern,
red cameras operate at a frame rate of 30 or 60 Hz, which is although one difference is that signals due to defects are
usually sufficient for inspection of composite assemblies. Some transitory, while those due to other sources (nearby hot objects)
infrared cameras are radiometric (meaning the infrared radia- are often constant. Therefore, looking at the evolving thermal
tion captured by the camera is translated to a temperature patterns over time normally yields additional important infor-
measurement). Radiometric cameras are often not needed, mation.
because the small contrast temperatures due to subsurface 13.4 Use of Referenced Documents
defects are often difficult to measure accurately. 13.4.1 For a general overview of passive and active ther-
13.3.4 Data storage may be either a single image showing a mographic methods using contact and noncontact methods for
defect at the optimum viewing time, or may be a sequence of acquiring the heat emission patterns, refer to MIL-HDBK-731.
images showing the development and subsequent fading of the 13.4.2 There are no ASTM standards specific to contact
defect indication. thermography, whether by passive or active excitation.
13.3.5 Repeatability of inspection is dependent upon both 13.4.3 Noncontact (Infrared) Methods:
the equipment and technique used. For example, convection 13.4.3.1 Consult Test Method E1213 for determination of
heating with hot or cold air is difficult to apply repeatability. the minimum resolvable temperature difference (MRTD) capa-
Non-uniform application of heating (or cooling) can cause bility of the compound observer-thermal imaging system as a
localized temperature variations that may me misinterpreted as function of spatial frequency. MRDT values provide estimates
defect locations. The best repeatability is achieved using of resolution capability and may be used to compare one
automated data acquisition and storage that is synchronized to system to another (lower MRDT values indicate better resolu-
the application of the thermal stimulus. tion).
13.3.6 Active ThermographyActive thermography re- 13.4.3.2 Consult Test Method E1311 for determination of
quires use of external stimulation to cause heat to flow (by the minimum detectable temperature difference (MDTD) ca-
diffusion) in an article under test. Heat may be introduced by pability of a compound observer-thermal imaging system as a

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
40
Downloaded/printed by
E2533 09
function of the angle subtended by the target. MDTD values with a direct viewing angle providing optimum results. View-
provide estimates of detection capability and may be used to ing angles of more than 45 degrees from normal should be
compare one system to another (lower MDTD values indicate avoided.
better detection capability). 13.6 Safety and Hazards
13.4.3.3 Consult Test Method E1543 for determination of 13.6.1 Thermographic test methods involve the use of
the noise equivalent temperature difference (NETD; NEDT) of heated or electrically energized equipment.
thermal imaging systems of the conventional forward-looking 13.6.2 Operation of hot air guns, flash lamps and flood
infrared (FLIR) or other types that utilize an optical- lamps may not be permitted in fuel-rich environments.
mechanical scanner; it does not include charge-coupled devices 13.7 Calibration and Standardization
or pyroelectric vidicons. Parts of this test method have been 13.7.1 Infrared CamerasInfrared cameras require peri-
formulated under the assumption of a photonic detector(s) at a odic re-calibration. At a minimum, the manufacturers recom-
standard background temperature of 295K (22C). Besides mendations should be adhered to. In addition, a suitable
non-uniformity, tests made at other background temperatures reference standard may be used to verify that the camera is
may result in impairment of precision and bias. NEDT relates functioning properly. It is recommended that the reference
to the minimum resolvable temperature difference, thus, an standard be evaluated prior to and following an infrared
increase in NEDT may be manifest as a loss of detail in the thermography inspection.
thermographic image. 13.8 Physical Reference Standards
13.4.3.4 Consult Test Methods E1862 for procedures for 13.8.1 Whenever possible, it is desirable to have a reference
measuring and compensating for reflected temperature when standard fabricated that is representative of the article under
measuring the surface temperature of a specimen with an test being evaluated. The reference standard should contain
infrared imaging radiometer. real or artificial imperfection or discontinuity areas that are
13.4.3.5 Consult Test Methods E1897 for procedures for representative of the required imperfection or discontinuity
measuring and compensating for transmittance when using an detection requirements.
infrared imaging radiometer to measure the temperature of a
specimen through an attenuating medium, such as a window, 14. Ultrasound
filter or atmosphere. 14.1 Referenced Documents
13.4.3.6 Consult Test Methods E1933 for procedures for 14.1.1 ASTM Standards:2
measuring and compensating for emissivity when measuring E114 Practice for Ultrasonic Pulse-Echo Straight-Beam Ex-
the surface temperature of a specimen with an infrared imag- amination by the Contact Method
ing. E214 Practice for Immersed Ultrasonic Examination by the
13.4.3.7 Consult Guide E1934 for a list of the responsibili- Reflection Method Using Pulsed Longitudinal Waves
ties of the end user and the infrared thermographer when E317 Practice for Evaluating Performance Characteristics
examining electrical and mechanical systems. This guide of Ultrasonic Pulse-Echo Examination Instruments and Sys-
outlines the specific content required to document qualitative tems Without the Use of Electronic Measurement Instruments
and quantitative infrared thermographic examinations. E664 Practice for the Measurement of the Apparent Attenu-
13.4.3.8 Consult Practice E2582 for discussion of a proce- ation of Longitudinal Ultrasonic Waves by Immersion Method
dure for detecting subsurface flaws in composite panels and E1001 Practice for the Detection and Evaluation of Discon-
repair patches, as applies to polymer or ceramic matrix tinuities by the Immersed Pulse-Echo Ultrasonic Method Using
composite structures with inspection surfaces that are suffi- Longitudinal Waves
ciently optically opaque to absorb incident light, and that have E1065 Guide for Evaluating Characteristics of Ultrasonic
sufficient emissivity to allow monitoring of the surface tem- Search Units
perature with an IR camera. E1324 Guide for Measuring Some Electronic Characteris-
13.5 Geometry and Size Considerations tics of Ultrasonic Examination Instruments
13.5.1 Since non-contact infrared thermography works on E1901 Guide for Detection and Evaluation of Discontinui-
the basis of optical field techniques, it can be applied to the ties by Contact Pulse-Echo Straight-Beam Ultrasonic Methods
quick observation of large surfaces. E2580 Practice for Ultrasonic Testing of Flat Panel Com-
13.5.2 For very thin materials such a composite laminates, it posites and Sandwich Core Materials Used in Aerospace
has been shown that the fidelity of surface thermal patterns to Applications
interior imperfections or discontinuities is good. For thicker SAE J428 Ultrasonic Inspection, Rev. Mar. 1991
composite materials, deeper defects will appear larger than 14.1.2 Military Handbooks and Standard:6
they actually are due to lateral heat flow (image processing MIL-HDBK-787 Nondestructive Testing Methods of Com-
methods are available to compensate for this). Also, as the posite MaterialsUltrasonics
cross-sectional dimensions of the defect area become compa- 14.2 General Procedure
rable to the defect depth, the apparent size will be larger than 14.2.1 All ultrasonic tests involve introducing controlled
the actual defect size. ultrasonic energy into the article under test, and observing how
13.5.3 The ability of the infrared camera to detect small the passage of sound is affected in transit. Any discontinuity
contrast temperatures is a function of the relative angle can reflect, disperse, or attenuate the energy. The ultrasonic
between the surface of the article under test and the camera, energy for testing is generated in short burst or pulses by

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
41
Downloaded/printed by
E2533 09
TABLE 15 Summary of Ultrasound
What Is Seen
Applications How It Works Advantages Limitations
and Reported?
General Overview: Detects The Basics: Pulsed, high General Overview: Detects General Overview: General Overview:
sub-surface imperfections frequency sound is sub-surface imperfections Requires a relatively flat Imperfections or
or discontinuities in introduced into the part or discontinuities including and smooth surface. discontinuities are not
composites. under test using a porosity, cracks, inclusions, directly imaged or
piezoelectric transducer of foreign materials, Material characteristics recorded. Imperfections or
Additional Information: a specific frequency. The delaminations, and crack- (modulus, surface discontinuities measured
transducer is coupled to like defects such as lack of condition, orientation of by comparing positive or
Method of choice for the part with a liquid fusion & lack of defects) can affect negative amplitude
finding delaminations and couplant to allow the sound penetration. inspectability. responses from reference
unbonds in composite to pass directly into the standard. Data can be
products. part. The transducer may Additional Information: Additional Information: presented in various
be in direct contact with formats, including a CRT
Can be automated to the part (contact testing) Numerous sound Reference standards are waveform presentation (A
screen parts during or maintained a specific transmission modes required, and may need to scan) or topographical
fabrication and distant from the part while available including be built, in order to mapping (C scan).
manufacturing. both are submerged in a longitudinal, shear and standardize equipment and
liquid medium (immersion surface waves. evaluate imperfections or Additional Information:
testing). The transmitted discontinuities.
sound is monitored for Numerous techniques Imperfections or
reflected echoes measured available including pulse- A liquid couplant is discontinuities are seen
in amplitude and/or time of echo and through- required. This can lead to on an oscilloscope with a
flight. Imperfections or transmission. possible fluid entrapment in time and amplitude display
discontinuities oriented faying surfaces and and then measured by
preferably at 90 degrees to Excellent volumetric internal cavities or possible comparing amplitude of
the sound path cause inspection, especially for fluid absorption into porous reflected signal from
these properties to be laminar imperfections or materials. imperfection or
altered and/or sound to be discontinuities. discontinuity with a
reflected, thus revealing Numerous ultrasonic standard reflector. Another
their relative sizes and Imperfection or techniques may need to be method of defect
locations (see What is discontinuity depth can be applied to ensure adequate evaluation is loss of back
Seen & Reported column). accurately measured. detectability of and internal reflection from areas where
Inspection may be imperfections or inadequate sound is
performed manually or Highly sensitive and discontinuities are varying reflected back to the
using automated systems. accurate. orientation because transducer.
ultrasonic inspection is not
Can be portable. sensitive to small
imperfections or
Automated systems discontinuities oriented
available for testing large parallel to the sound beam.
parts.

Equipment can vary from


simple and inexpensive
portable A-scan systems to
massive C-scan gantry
systems capable of
manipulating the part and
acquiring massive amounts
of data.

piezoelectric transducers driven by appropriate electronic cir- or discontinuity detection in PMCs are performed in the
cuitry. Test frequencies used are usually between 1 to 25 MHz. immersion mode and the data is recorded in a planer mode
Since air will not support these higher ultrasonic frequencies, a known as a C-scan.
liquid such as water or oil is used as a couplant between the 14.2.2 Types of Techniques:
transducer and the article under test. Two procedures, contact
14.2.2.1 Pulse EchoA pulse of ultrasonic energy is trans-
and immersion testing, are used in ultrasonic inspection. In any
mitted into the article under test. The time required for the
application, the material under test should be cleaned to
reflected energy to return to the transducer is observed. A
remove loose particles or debris prior to inspection. In contact
testing, the transducer is used in the pulse echo mode and is discontinuity is usually indicated by (1) reflection received
placed directly against the article under test with a film of from location where no physical discontinuities (such as end
liquid couplant between them. In immersion testing, the article faces, grooves, or holes) are known to exist, or (2) loss of the
under test is placed in a reservoir of water, and the transducer reflection from the known physical discontinuity.
placed close to, but not in contact with the article under test. 14.2.2.2 Through TransmissionEither a pulsed or con-
Water columns between the transducers and test surface may tinuous beam of ultrasonic energy is coupled into the article
also be used when immersion is undesirable. For ease and under test from the sending transducer. A second transducer,
speed of scanning most interrogations involving imperfection the receiver, is placed in a position to receive the transmitted

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
42
Downloaded/printed by
E2533 09
energy. Changes in the negative amplitude of the received (immersion procedures are normally preferred). For example, it
energy indicate discontinuities in the part. may be very difficult to resolve the far ply interface when plies
14.2.3 Types of Procedures: are very thin.
14.2.3.1 Contact TestingThe transducer is placed directly 14.3.6 Through Transmission:
against the article under test, with a film of compatible liquid 14.3.6.1 Advantages and ApplicationsThe ultrasound en-
couplant between them. ergy passes through the article under test only one time,
allowing this test to be used on materials difficult to penetrate
14.2.3.2 Immersion TestingThe article under test is placed
as well as thin materials.
in a reservoir of couplant liquid, usually water. The transducer
is immersed in the reservoir and accurately positioned relative NOTE 14The use of bubblers and squirters is particularly well suited
to the article under test. Water columns between the transduc- for measurements of composites with contoured surfaces.
ers and test surface may also be used if immersion is 14.3.6.2 Limitations and InterferencesPrecision fixturing
undesirable. for two transducers and preparation of two test surfaces are
14.3 Significance and Use required (transducers must be critically aligned and their
14.3.1 One of the most widely used NDT inspection tech- motion synchronized). The through transmission technique
niques for composite materials and components is ultrasonic also has poorer resolution and sensitivity compared to the pulse
through-transmission C-scan inspection and ultrasonic pulse- echo method. Discontinuity depth cannot be determined by
echo A-scan inspection. Since the subject is so broad, and the through testing. Use of this technique is best applied with the
number of possible ultrasonic techniques and procedures so aid of recording equipment (C-scan).
diverse, the engineering requirements and the accept/reject 14.3.7 Contact Testing:
criteria are usually contained in a document that is referenced 14.3.7.1 Advantages and ApplicationsContact testing in-
in the users process specification. volves low cost equipment. Portable, battery-operating equip-
14.3.2 Through transmission technique with the aid of ment is also available. Quite often this procedure is used to
electronic recording equipment (C-scan) are well suited for the verify imperfections or discontinuities found using through
inspection of laminate structures. This is by far the one of the transmission, that is, depth information. This method is com-
most common applied methods for detecting delaminations, monly used in the field for composite damage assessment.
de-bonding and porosity type defects. 14.3.7.2 Limitations and InterferencesSince rough sur-
14.3.3 Although information about a variety of possible faces can scatter and attenuate the sound energy, a reasonably
defects or internal discontinuities can be provided by the smooth surface is required. Also, the energy cannot be readily
ultrasonic techniques, the principal defects evaluated are inter- focused to obtain better resolution and sensitivity in the given
nal voids/void content, de-bonds, delaminations, and porosity. analysis area (it is difficult to control the shape and direction of
Determination of fiber orientation is also possible. the beam). The transducer is also subject to wear thus requiring
14.3.4 In many cases, the extent of discontinuities can be replacement or wear/shoes in some applications. Last, sensi-
determined. The minimum detectable discontinuity size will tivity is variable depending on couplant efficiency.
depend on: 14.3.8 Immersion Testing:
14.3.8.1 Advantages and ApplicationsImmersion testing
14.3.4.1 The sensitivity of the test equipment.
allows the energy to be focused or shaped for the article under
(1) Physical characteristic of the transducer. test, thus increasing resolution and sensitivity. Immersion
(2) Gain/band width characteristics of the instrument. coupling facilitates inspection of nonuniformly contoured parts
14.3.4.2 The material inspected. and lend itself better to automatic inspection and recording of
(1) Physical properties (modulus, crystallinity, fiber con- results.
tent). 14.3.8.2 Limitations and InterferencesThrough transmis-
(2) Surface condition (that is, rough, smooth, wavy, scaly, sion requires access to both side of the composite. Composite
coated). materials are not normally suitable for submersion in a bath of
14.3.4.3 The frequency used (in general, higher test fre- water. Allowable article under test size is also limited by the
quencies allow detection of smaller discontinuities; lower immersion reservoir size, and equipment is more expensive
frequencies allow penetration of greater thickness of material). than that used in contact methods.
14.4 Use of Referenced Documents
14.3.4.4 Orientation of a discontinuity and its distance from
14.4.1 General:
the ultrasonic entrant surface can be obtained using the pulse
14.4.1.1 Consult MIL-HDBK-787 for discussions on ultra-
echo technique.
sonic determination of fiber orientation, void content, delami-
14.3.5 Pulse Echo: nations, strength-related properties (for example, ultimate
14.3.5.1 Advantages and ApplicationsSingle transducer strength) using a stress wave factor (SWF), fatigue damage,
operation allows inspection with access to only one side of the impact damage, and elastic constants within a stiffness matrix.
article under test. The resolution and sensitivity of the pulse 14.4.2 Pulse Echo:
echo method is dependent on the ultrasonic probe characteris- 14.4.2.1 Consult Practice E114 for ultrasonic examination
tics. of articles under test by the pulse-echo method using straight-
14.3.5.2 Limitations and InterferencesThe minimum beam longitudinal waves introduced by direct contact of the
thickness of a article under test will depend on the procedure search unit with the material being examined. This practice is

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
43
Downloaded/printed by
E2533 09
applicable to the development of an examination procedure flat sandwich core panels (parallel surfaces), namely, Test
agreed upon by the purchaser (cognizant engineering organi- Procedure A, Pulse Echo, and Test Procedure B, Through
zation) and the supplier. Transmission procedures.
14.4.2.2 Consult Practice E214 for procedures for detecting 14.4.3 Through Transmission:
discontinuities in material using instruments that transmit and 14.4.3.1 There are no known applicable ASTM standards
receive pulsed longitudinal ultrasonic waves introduced into for through transmission ultrasonic characterization of materi-
the material to be examined while immersed in or impinged als, composite or otherwise. Consult MIL-HDBK-787 for
upon by a liquid coupling agent. This practice applies to any discussions on through transmission ultrasonic characterization
material that can conduct sound waves of an appropriate of composite materials and components.
frequency, and can be immersed in a liquid coupling agent for 14.4.4 Equipment and Instrumentation:
inspection, or can be subject to inspection by the use of a 14.4.4.1 Consult Guide E1324 for procedures for measuring
column or stream of the couplant between the search unit and the following performance-related characteristics of ultrasonic
the material being examined. instruments.
NOTE 15Practice E1001 is a complementary document that extends 14.4.4.2 TransducersConsult Guide E1065 for evaluating
Practice E214 by describing more detailed procedures. certain characteristics of ultrasonic search units that are used
with ultrasonic examination instrumentation. This guide de-
14.4.2.3 Consult Practice E664 for measuring the apparent
scribes means for obtaining performance data that may be used
attenuation of ultrasound in materials or components with flat,
to define the acoustic and electric responses of ultrasonic
parallel surfaces using conventional pulse-echo ultrasonic
search units.
imperfection or discontinuity detection equipment in which
reflected indications are displayed in an A-scan presentation. 14.5 Geometry and Size Considerations
The measurement procedure is readily adaptable for the 14.5.1 Ultrasonic transducers, often called search units, are
determination of relative attenuation between materials. For typically less than 25 mm (1 in.) in diameter. These transducers
absolute (true) attenuation measurements, indicative of the may have different exit sound characteristics. Thus, when
intrinsic nature of the material, it is necessary to correct for inspecting large objects, it is necessary to scan the object with
specimen geometry, sound beam divergence, instrumentation, consideration to the effective sound beam dimension associated
and procedural effects. These results can be obtained with more with the transducer.
specialized ultrasonic equipment and techniques. This Practice 14.5.2 If the article under test is sufficiently thick to resolve
is concerned with the attenuation of longitudinal wave intro- successive back reflections, then one can resort to a pulse echo
duced into a article under test by an immersion method. scanning technique utilizing a single transducer. The selection
14.4.2.4 Consult Practice E1001 for procedures for the of transducer and pulse receiver can demonstrate significant
ultrasonic examination of bulk materials or parts by transmit- resolve for thinner structures. If, on the other hand, the article
ting pulsed, longitudinal waves through a liquid couplant into under test is too thin or very attenuating, then one must resort
the material and observing the indications of reflected waves. It to a through transmission scanning technique utilizing two
covers only examinations in which one search unit is used as transducers.
both transmitter and receiver (pulse-echo) and in which the part 14.5.3 For rounded surfaces, geometry must be considered
or material being examined is totally submerged in the cou- when using contact pulse-echo methods. For example, refer-
plant (immersion testing). This practice includes general re- ence blocks with flat surfaces may be used for establishing gain
quirements and procedures which may be used for detecting settings for examinations on test surfaces with radii of curva-
discontinuities and for making a relative or approximate ture of the order of 4 to 5 in. (100 to 130 mm) or greater. For
evaluation of the size of discontinuities. This practice comple- test surfaces with radii of curvature less than 4 to 5 in.,
ments Practice E214 by providing more detailed procedures for reference blocks with the same nominal curvature should be
the selection and calibration of the inspection system and for used, unless otherwise agreed upon by the purchaser and
evaluation of the indications obtained. supplier.
14.4.2.5 Consult Guide E1901 for contact ultrasonic exami- 14.5.4 Examination SurfaceSurfaces should be uniform
nation of bulk materials or parts by transmitting pulsed and free of foreign material which can inhibit the ability to
ultrasonic waves into the material and observing the indica- induce adequate acoustic coupling.
tions of reflected waves. This guide covers only examinations 14.5.5 Geometric SimilarityWhen comparing the appar-
in which one search unit is used as both transmitter and ent attenuations in different composite material or components,
receiver (pulse-echo). This guide includes general require- the articles under test under examination must be geometrically
ments and procedures that may be used for detecting discon- similar, and of course is relative to the transducer and tech-
tinuities, locating depth and distance from a point of reference nique applied. For example: a focused transducer used on a
and for making a relative or approximate evaluation of the size thin laminate with a small diameter sound beam may tolerate
of discontinuities as compared to a reference standard. This curvature differences. On the other hand use of a large sound
guide complements Practice E114 by providing more detailed beam will have greater beam modification with the smaller
procedures for the selection and calibration of the inspection radii part shapes.
system and for evaluation of the indications obtained. 14.6 Safety and Hazards
14.4.2.6 Consult Practice E2580 for a description two pro- 14.6.1 Precautions must be taken to preclude the possibility
cedures for ultrasonic testing (UT) of flat panel composites and of electrical shock when performing ultrasonic testing.

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
44
Downloaded/printed by
E2533 09
14.7 Calibration and Standardization 15. Visual NDT
14.7.1 The cognizant engineering organization should ap- 15.1 Referenced Documents
prove the required calibration procedure and interval. 15.1.1 ASNT Handbook:3
14.7.2 Ultrasonic inspections require fabrication of physical
Nondestructive Testing Handbook, Visual and Optical Test-
reference standards from similar acoustic material with built-
ing, Vol. 8
in, known defects that closely resemble the defects for which
information is sought. SNT-TC-1A Recommended Practice for Personnel Qualifi-
14.7.3 If quantitative information is to be obtained, vertical cation and Certification in Nondestructive Testing
or horizontal linearity of both should be checked in accordance 15.2 General Procedure
with Practice E317 or other procedure approved by the 15.2.1 Light patterns reaching the human eye are processed
examining agency and the customer. An acceptable linearity as lines, spots, edges, shadows, colors, orientations and/or
performance may be agreed upon between the examining reference locations within the field of view. The visual obser-
agency and customer. vation is then compared with long-term memory of previously
14.8 Physical Reference Standards made observations, and differences due to variations in shape,
14.8.1 Pulse Echo Reference Standards and BlocksThe pattern and color made. Visual NDT is often used in conjunc-
article under test itself may be an adequate standard using the tion with other NDT methods, for example, inspecting a
back wall echo for reference. For more quantitative informa- composites surface for the presence of cracks, pits, or voids,
tion, machined artificial reflectors (discontinuities) or charts before performing more elaborate and costly NDT methods
representing distance-amplitude relationships of known reflec- such as radiography. In many cases, visual NDT can be
tors sizes for a particular search unit and material may be used enhanced and extended by the use of mirrors, chemicals,
for standardization. The artificial reflectors may be in the form magnifiers, borescopes, illuminating devices, and image pro-
of foreign materials inserted during lay-up, induced porosity, cessing equipment.
flat-bottom holes, side drilled holes, or slots. The surface finish 15.3 Significance and Use
of the reference standard should be similar to that of the 15.3.1 Visual inspection by an experienced inspector is one
production item. The reference standard material and produc- of the most important yet simple NDT techniques to use. It
tion material should be acoustically similar (in velocity and provides inexpensive, wide field assurance that components
attenuation). The reference standard selected shall be used by meet the manufactures criteria and are free from mechanical
the examiner as the basis for signal comparisons. damage.

TABLE 16 Summary of Visual NDT


What Is Seen
Applications How It Works Advantages Limitations
and Reported?
Used to inspect surfaces Light patterns reaching the Can yield quantitative data Insensitive to bulk features Since a transient visible
for cracks due to fatigue or human eye are processed more readily than other and characteristics. light image is seen,
impact damage, pitting, as lines, spots, edges, NDT methods. permanent documentation
voids, pores, inclusions, shadows, colors, Complex structures with using film-based or video
and to evaluate surface orientations and reference Can be performed without recessed or interior photography is used
finish. locations within the field of any intervening apparatus. surfaces may not be extensively. Low
view. The visual inspectable. magnification film
Used during the fabrication observation is then When equipment is photography is useful for
and manufacturing cycle to compared with long-term required, it is usually Observations are user documenting surface
ensure product quality. memory of previously inexpensive (for example, dependent (due to discontinuities, while video
made observations, and mirrors, borescopes and differences in visual photography is useful for
When used in conjunction differences due to magnifiers). acuity). documenting inaccessible
with mechanically aided variations in shape, pattern areas, particularly when
measurements, can be and color made. To standardize results, moving an imaging device
used to verify dimensions periodic visual acuity into inaccessible areas with
and tolerances. examinations are the video recorder turned
recommended. on.
Used during failure
analysis, for example, to Similarly shaped or colored
assess color changes objects or patterns may be
caused by overheating, hard to differentiate.
oxidation, etc.
Color differentiation tends
Used during in-service to be more difficult than
inspection to detect geometric pattern
imperfections or differentiation.
discontinuities and monitor
growth. Scanning for multiple
defects takes longer than
for single defects.

The presence of a defect


will be easier to ascertain
than its absence.

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
45
Downloaded/printed by
E2533 09
15.3.2 Visual NDT involves qualitative physical inspection handling-induced damage. Delamination, cracking and buck-
of a composite material or component to detect gross imper- ling may occur. Indications may necessitate follow-up NDT
fections or discontinuities, but may require confirmation by using other methods.
other destructive or nondestructive means to definitively ensure 15.3.6 Limitations and Interferences:
that the material or component meets engineering drawing 15.3.6.1 Insensitive to bulk features and characteristics.
requirements and no mechanical damage has occurred. This NDT method cannot yield information on the depth and
15.3.3 Visual inspection includes but is not limited to extent of the indication. This NDT method should be comple-
examination for cracks, surface breaking delaminations, blis- mented with additional NDT to better understand the nature of
ters, depressions, foreign material inclusions, ply distortions, indications. Familiarity with the manufacturing process and
surface finish, broken fibers or wrinkles. damage tolerance must be understood to provide adequate
15.3.4 Complete visual inspection may involve review of a visual inspection screening.
material or components data package to verify proper materi- 15.3.6.2 Due to user dependent variations in near and far
als and dimensions are maintained. It may also involve vision acuity, color vision, depth perception, peripheral vision,
inspection of quality records (impact control plan, certificates and stereoscopic vision, repeatability and reproducibility errors
of material conformance, etc.) to verify inspection points, can be significant.
required documentation, and to ensure engineering design is 15.4 Use of Referenced Documents
maintained. In some instances these data review and dimen- 15.4.1 For details on personnel qualification, training and
sional check portions of the inspection are conducted by an certification, consult ASNT SNT-TC-1A.
inspector assigned to the fabrication work area while the defect 15.4.2 For detailed descriptions of the physiology of sight,
screening inspection is performed by a qualified NDT special- visual acuity testing, measurement of light, testing environ-
ist more familiar with defect detection and the other NDT ment, aids and accessories, codes and standards, interfacing of
inspection processes, which may be needed to confirm Visual visual NDT with other NDT methods, consult ASNT Nonde-
NDT inspection results. A qualitative description of any defects structive Testing Handbook, Vol. 8.
(cracks, delaminations, blisters, depressions, foreign material 15.5 Geometry and Size Considerations
inclusions, ply distortions, surface features, or wrinkles) shall 15.5.1 When examining large areas, peripheral vision ef-
be provided, along with corresponding quantitative details fects, which can alter contrast and color differentiation as well
(location, number, size, size distribution). For archival and as depth perception, become more important.
reference purposes, inspection sheets with photo and or video 15.6 Safety and Hazards
documentation is recommended. Good documentation proce- 15.6.1 Given the variety of visual tasks and types of
dures should be implemented through training and qualification illumination used, it is important to consider the possible
testing and shall be followed. long-term effects on visual acuity of excessive exposure to
15.3.5 Advantages and Applications: light, for example, when high luminance visible light sources
are used, or that can even result from using insufficient light
15.3.5.1 This method provides a rapid, wide field survey of
sources.
a composite structure to ensure design and material compli-
ance. It also ensures that no mechanical damage has occurred 15.7 Calibration and Standardization
to the component. This NDT method shall be complemented 15.7.1 Since evaluations involving the human eye can be
with additional NDT to better understand the nature of the highly variable and subjective, visual inspectors should be
indication. For example, visual NDT can be used to accept or certified periodically to ensure a necessary level of natural or
reject large, costly aerospace structures to verify the absence of corrected visual acuity, especially when visual NDT is per-
surface voids, excessive wrinkles, or buckling. Once the formed on composite materials and components used in critical
structure is accepted, more precise NDT methods can be used applications. Formal procedures for qualifying visual inspec-
such as ultrasound for detection of delamination, and radiog- tors can be found in ASNT SNT-TC-1A. In general, eye charts
raphy for detection of voids and porosity. are used to measure near and far vision acuity. For example, a
Jaeger eye chart placed 40 cm (12 in.) from the eye or eyeglass
15.3.5.2 Visual NDT of is performed immediately after plane is used in the United States for near vision acuity
manufacturing, usually without the aid of magnification, to examinations. Eye charts placed 6 m (200 ft) from the eye or
ascertain the presence of excessive wrinkles, holes, gaps eyeglass plane are used in far vision acuity examinations. More
between adjacent plies, surface voids, cracks, bucking, fiber clinically precise visual acuity examinations are also available,
alignment problems, etc. for example, color cap charts for assessing color vision acuity.
15.3.5.3 A more elaborate visual inspection may be required Both eyes are tested independently.
that entails looking for resin rich and resin starved regions, 15.7.2 Personnel performing visual inspections shall be
blisters or delaminations in exterior plies, surface voids and trained and qualified in the field of composite inspection.
edge separations. If the matrix is semitransparent, internal However, specialized visual inspection training and certifica-
voids can be detected by shining a high intensity light through tion opportunities specific to the inspection of composite
the structure and viewing in a darkened area. materials are not as commonly available as for other applica-
15.3.5.4 Visual NDT is often required during in-service tions (for example, visual weld inspection). The employer may
inspection, especially for composite materials and components need to develop and administer adequate training, applicable to
exposed to weather, thermal fluctuations, and impact or the applications and product being inspected.

Copyright by ASTM Int'l (all rights reserved); Mon Sep 17 00:56:24 EDT 2012
46
Downloaded/printed by
E2533 09
15.7.3 Proper posture, control of viewing angle, adequate inspections, incandescent lighting is recommended. A mini-
lighting (the human eye operates optimally under normal mum intensity of 160 lx (15 ftc) should be used for general
daylight illumination) are important considerations that need to visual testing. A minimum of 500 lx (50 ftc) should be used for
be taken into account when performing visual inspections. critical or fine detail testing.
15.7.3.1 When inspecting reflective surfaces, the viewing
NOTE 16Incandescent light sources are generally preferred when
angle should be off normal but not exceed 45 degrees. When differentiating lines, spots, edges, shadows, and orientations. Fluorescent
inspecting nonreflective surfaces, the preferred viewing angle lamps, especially those listed at full spectrum, are good for color
should be normal to the inspected surface. examinations.
15.7.3.2 Since visual NDT methods involving physical NOTE 17Oblique lighting should be used to distinguish between
inspection may be highly subjective, repeatability and repro- protruding or concave surface features.
ducibility errors must be known and controlled. These errors
15.8 Physical Reference Standards
shall be minimized and controlled through proper training and
associated certification programs. To minimize these errors 15.8.1 Vision acuity charts consisting of black characters or
standardized inspection procedures should be implemented. letters on a white matte background, and illuminated by room
Conveying detailed specific criteria and instructions as well as lighting sufficient to bring the chart background luminance up
maintaining a set of sketches, photographs, or actual defective to 85 6 5cd m2, are recommended.
parts containing the size and types of imperfections or discon-
tinuities expected can greatly reduce the subjective variations 16. Keywords
between inspectors. 16.1 acoustic emission (AE); aerospace composites; bubble
15.7.3.3 Visual inspections should be performed at 25 to 60 leak testing; composite shell; computed radiography (CR);
cm (10 to 24 in.). computed tomography (CT); conductivity leak test; digital
15.7.3.4 Both human vision acuity and the resolution of detector arrays (DDA); digital radiography (DR); fiber rein-
electronic imaging equipment systems are greatly reduced as forced composites; helium leak testing; high modulus fibers;
the viewing distance is increased. Lenses or imaging systems high performance composites; hydrostatic leak testing; image
that can reduce the viewing focal distance below 10 in. provide quality indicator (IQI); infrared thermography; leak testing;
the benefit of relative magnification. (for example, a bore scope nondestructive evaluation (NDE); nondestructive inspection
lens able to focus at a 12-in. focal distance provides the (NDI); nondestructive testing (NDT); penetrating radiation;
equivalent magnification of 203). polymeric matrix composites (PMC); pulse-echo; radiography
15.7.3.5 As a general rule, it is recommended to match the (RT); radioscopy or realtime radiology (RTR); shearography;
relative resolution of digital viewing system components. strain gauges; strain measurement; thermal conductivity leak
15.7.3.6 There must be a source of natural or artificial light test; thermal imaging systems; thermography; tomography;
of adequate intensity and spectral distribution. For most visual ultrasound (UT); visual NDT

ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.

This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.

This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org).