Вы находитесь на странице: 1из 2

PASOLINK Page

NWD-008717-018 24/32
Work instruction of connector for PASOLINK.

6
Rev.:01 Dateofissue:15.11.04 Maker work instruction :JAHL-2073-13
Product name/
Specification Acceptable cable Specification
maker model
5D-FB-E RKS-W-1007-036
N-SP-5DFB-W(4) /
10 CBE-108261-001-00 5D-FB-E(LW) CBE-101412-001-00
N000A107D52
5D-FB-E(LW)N CBE-108314-001-00
[Outlines of parts]

Cable jacket Aluminum tape Plug body Sleeve Gasket Washer Shell

Center conductor

Braided wire Insulator

Tools
(Knife),(cutter),(nipper),(tweezers),(File),(measure) Clearance gauge) etc.,
( 16mm) (Spanner , Torque spanner 16mm)
procedure
1. Remove of jacket of cable 3. Center conductor processing
1)

Remove 6.5mm of jacket only.


1) Fold the braided wire to the sleeve side.
The braided wire which sticks out from R of a
sleeve is cut
6.50.5
braided wire cutoff point

Note: Not doing damage to the braided wire.

2. Insertion of parts Sleeve

2)
2) Remove of insulator and aluminum tape as shown
The Shell, the washer and the gasket ,sleeve are without damaging the center conductor.
inserted in the cable.
3)
Gasket Washer
Shell
3) The size of the center conductor is confirmed.
If the burr to the cable center conductor has
Sleeve occurred, remove by cutter knife etc..

Insulator and aluminum tape cutoff point

burr
(knife) (cutter)
Tools (measure) etc.,
cut
5 0.5

Please be careful about the insertion directions of each (cutter)


part. Tools (nipper) etc.,
PASOLINK Page
NWD-008717-018 25/32
Work instruction of connector for PASOLINK.

4. Connector assembly 1:
1)
1) Insert the cable assembly in a plug body. 2:

Plug body Cable assy Note1:When inserting, don't put the chip which is
braided wire inside the central conductor
and the plug body.
Note2:Dontturnplugbody,turnshellattachment.

2)
5)
2) When inserting a cable, a center conductor 1.8~2mm
would touch contact and stop once. :
3)
3) It'll be the normal location by forcing additionally.
5) The gap of the plug body and shell is confirmed.
Gap: 1.8~2.0mm

(Spanner) (16mm)
(16mm)
Section Tools (Torque spanner)
,
(Clearance gauge) (measure)

:1
1

Section

Note: Don't remove the plug body tightened up once.


4) ( ) When removing, it's reworked from procedure
1 or a cable is exchanged.
2 3N m
4) Tighten the connection to the torque value of
2~3N m.
(Plug body)
(shell)

1.8 2mm
Gap is reference