YXC7V-R

N2XSY

20,3/35kVXLPEinsulatedsinglecorecableswithcopperconductor

Description

Application:
Thesearecableswithlowdielectriclossesusedinenergynetworkwithsudden
loadchanges.Laidinresidentalorindustrialareas,undergroundorinducts.

Construction:
1. Conductor:Copper
2. Conductorscreen:Semiconductingcompound(XLPE)
3. Insulation:XLPE
4. Insulationscreen:Semiconductingcompound(XLPE)
5. Semiconductingtape:Crapetape
6. Metallicscreen:Concentric/Copperwires+coppertape
7. Outersheath:PVC Standards
NationalTSEK

Marking:
<>TSEK<>NEXANSYXC7VR1x240/2520,3/35kV2012(Meter)

Characteristics
Dimensional characteristics
Numberofcores 1
Usage characteristics
Operatingtemperature,range 20..60C
Maximumoperatingtemperature 90C
Shortcircuitmax.conductortemperature 250C
Flameretardant IEC603321&3
Bendingfactorwhenlaying 15(xD)

Operatingtemp. Maximumoperatingtemperature Flameretardant Bendingfactorwhenlaying


20..60C 90C IEC603321&3 15(xD)

Version V2.2 Generated 6/7/17 - http://www.nexans.com.tr Page1/3


Alldrawings,designs,specications,plansandparticularsofweights,sizeanddimensionscontainedinthetechnicalorcommercialdocumentationof
NexansisindicativeonlyandshallnotbebindingonNexansorbetreatedasconstitutingarepresentationonthepartofNexans.
YXC7V-R
Characteristics
Conductor cross-section 35 50 70 95 120 mm
Perm. current rating buried 20C - flat formation 214 251 306 363 410 A
Perm. current rating in air 30C - trefoil formation 202 241 299 362 416 A
Perm. current rating in air 30C - flat formation 233 279 348 421 483 A
Delivery reel size for 1000m 180 180 200 210 210 cm
Approximate weight 1400 1500 1800 2250 2500 kg/km
Nominal phase capacitance 0.106 0.116 0.128 0.141 0.152 F/km
Nominal outer diameter 33.0 35.0 36.0 38.0 40.0 mm
Perm. current rating buried 20C - trefoil formation 192 226 276 329 373 A
Max. DC resistance of the conductor at 20C 0.524 0.387 0.268 0.193 0.153 Ohm/km

Conductor cross-section 150 185 240 300 400 mm


Perm. current rating buried 20C - flat formation 449 503 576 641 697 A
Perm. current rating in air 30C - trefoil formation 469 536 630 717 823 A
Perm. current rating in air 30C - flat formation 540 615 718 812 904 A
Delivery reel size for 1000m 220 230 230 240 250 cm
Approximate weight 2750 3250 4000 4500 5500 kg/km
Nominal phase capacitance 0.162 0.174 0.192 0.208 0.228 F/km
Nominal outer diameter 41.0 43.0 45.0 48.0 51.0 mm
Perm. current rating buried 20C - trefoil formation 415 468 541 608 684 A
Max. DC resistance of the conductor at 20C 0.124 0.099 0.075 0.06 0.047 Ohm/km

Conductor cross-section 500 mm


Perm. current rating buried 20C - flat formation 768 A
Perm. current rating in air 30C - trefoil formation 929 A
Perm. current rating in air 30C - flat formation 1011 A
Delivery reel size for 1000m 250 cm
Approximate weight 6750 kg/km
Nominal phase capacitance 0.256 F/km
Nominal outer diameter 55.0 mm
Perm. current rating buried 20C - trefoil formation 762 A
Max. DC resistance of the conductor at 20C 0.037 Ohm/km

ProductList =Maketoorder, =Instock


Nexans ref. Name Cross section (mm)
22P0135T2B00200A15E000 1x35/16mm2 35
=Maketoorder, =Instock

Operatingtemp. Maximumoperatingtemperature Flameretardant Bendingfactorwhenlaying


20..60C 90C IEC603321&3 15(xD)

Version V2.2 Generated 6/7/17 - http://www.nexans.com.tr Page2/3


Alldrawings,designs,specications,plansandparticularsofweights,sizeanddimensionscontainedinthetechnicalorcommercialdocumentationof
NexansisindicativeonlyandshallnotbebindingonNexansorbetreatedasconstitutingarepresentationonthepartofNexans.
YXC7V-R
Nexans ref. Name Cross section (mm)
22P0150T2B00200A15E000 1x50/16mm2 50
22P0170T2B00200A15E000 1x70/16mm2 70
22P0195T2B00200A15E000 1x95/16mm2 95
22P012DT2B00200A15E000 1x120/16mm2 120
22P015DT2B00200A15E000 1x150/25mm2 150
22P018DT2B00200A15E000 1x185/25mm2 185
22P014ET2B00200A15E000 1x240/25mm2 240
22P013FT2B00200A15E000 1x300/25mm2 300
22P014GT2B00200A15E000 1x400/35mm2 400
22P015HT2B00200A15E000 1x500/35mm2 500
=Maketoorder, =Instock

Operatingtemp. Maximumoperatingtemperature Flameretardant Bendingfactorwhenlaying


20..60C 90C IEC603321&3 15(xD)

Version V2.2 Generated 6/7/17 - http://www.nexans.com.tr Page3/3