MODELS 90-5000
OPERATORS MANUAL
PRINT LANGUAGE
ENGLISH
FRENCH
PORTUGUESES
SPANISH
C.C.N. : 80442833 en
DATE : APRIL 2010
REV. :D
CONTENTS
CONTENTS PAGE CONTENTS PAGE
The Ingersoll Rand Heatless Desiccant Dryers are designed to adsorb (regeneration). After an initial rapid depressurization, a portion of dried
moisture from compressed air. The dryers are constructed with two air from the online tower passes over the desiccant bed and carries the
towers, each containing desiccant beads, that alternate between online moisture off the bed and out the dryer's exhaust.
(drying) and offline (regenerating) modes, yielding a continuous stream
of dry air at the dryer's outlet. The continuous, alternating process of adsorption and desorption is
controlled using a timer that switches the towers in a specific timed
During normal operation, wet air passes through the on line tower and sequence. Very dry compressed air dew points are achieved through
water vapor from the air is adsorbed (collected) on the desiccant beads. the continuous switching and operation of this dryer. Ingersoll Rand
While air is being adsorbed in the online tower, the moisture on the offers dryers to provide either -40F or -100F pressure dew point outlet
desiccant in the offline tower is removed by a process called desorption air.
3.0 WARRANTY
The Company warrants that the equipment manufactured by it and THE COMPANY MAKES NO OTHER WARRANTY OR
delivered hereunder will be free of defects in material and workmanship REPRESENTATION OF ANY KIND WHATSOEVER, EXPRESSED OR
for a period of twelve months from the date of placing the Equipment in IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES
operation or eighteen months from the date of shipment from the factory, OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
whichever shall first occur. The Purchaser shall be obligated to promptly PURPOSE, ARE HERBY DISCLAIMED.
report any failure to conform to this warranty, in writing to the Company
in said period, whereupon the Company shall, at its option, correct such Correction by the Company of nonconformities whether patent or latent,
nonconformity, by suitable repair to such equipment or, furnish a in the manner and for the period of time provided above, shall constitute
replacement part F.O.B. point of shipment, provided the Purchaser has fulfillment of all liabilities of the Company for such nonconformities
stored, installed, maintained and operated such Equipment in whether based on contract, warranty negligence, indemnity, strict liability
accordance with good industry practices and has complied with specific or otherwise with respect to or arising out of such Equipment.
recommendations of the Company. Accessories or equipment furnished
by the Company, but manufactured by others, shall carry whatever The Purchaser shall not operate Equipment which is considered to be
warranty the manufacturers have conveyed to the Company and which defective, without first notifying the Company in writing of its intention to
can be passed on to the Purchaser. The Company shall not be liable for do so. Any such use of Equipment will be at Purchaser's sole risk and
any repairs, replacements, or adjustments to the Equipment or any costs liability.
of labor performed by the Purchaser or others without Company's prior
written approval. Note that this is Ingersoll Rand standard warranty. Any warranty in force
at the time of purchase of the equipment or negotiated as part of the
The effects of corrosion, erosion and normal wear and tear are purchase order may take precedence over this warranty.
specifically excluded. Performance warranties are limited to those
specifically stated within the Company's proposal. Unless responsibility
for meeting such performance warranties are limited to specified tests,
the Company's obligation shall be to correct in the manner and for the
period of time provided above.
* Nominal Flows indicated are for 100F inlet temperature, 100F ambient temperature and 100 psig compressed air pressure.
NOTICE
Nomenclature shown above represents standard price sheet options. Other options are
available, refer to nomenclature insert specific to your dryer for details.
5.1 INSPECTION
Upon receiving your Ingersoll Rand air dryer, please inspect the unit Refer to labels on the dryer for the appropriate means for lifting or
closely. If rough handling has been detected, please note it on your moving the dryer. When lifting the dryer, ensure that no stress is applied
delivery receipt, especially if the dryer will not be immediately uncrated. to the piping or valving. Refer to Section 9.2 for locating and mounting
Obtaining the delivery person's signed agreement to any noted of dryer.
damages will facilitate any insurance claims
WARNING
Under no circumstances should any person attempt to lift heavy
objects without proper lifting equipment (i.e., crane, hoist, slings or fork
truck). Lifting any unit without proper lifting equipment, can cause
serious injury.
7.1 INTRODUCTION The purge adjustment manifold consists of the Purge Adjustment Valve,
As described in Section 2, water vapor is removed from compressed air the Purge Pressure Gauge and the Purge Orifice. Manually adjust the
by diverting air flow alternately between two towers filled with desiccant. Purge Adjustment Valve until the gauge reading on the purge pressure
While one tower processes the compressed air stream, adsorbing water gauge matches the Purge Pressure Gauge setting listed on the
vapor, the opposite tower is regenerated by desorbing the water vapor laminated tag affixed to the Orifice Plate Assembly.
and venting it to atmosphere. Refer to the Flow Diagram for a visual
representation of the drying and regenerating cycles.
NOTICE
On dryers equipped with the optional EMS feature, the purge valve
7.2 DRYING CYCLE MUST be set to the factory set point to ensure proper operation of this
Saturated compressed air enters the dryer and is diverted to the feature.
appropriate tower by the Inlet Flow Valves. Referring to the Flow
Diagram (Section 16.0), the Left Inlet Flow Valve is actuated to a closed 7.5 TOWER REPRESSURIZATION
position to prevent air flow from entering the regenerating tower.
Upon completion of tower regeneration, and prior to the Inlet Flow
Simultaneously, the Right Inlet Flow Valve is actuated to an open
Valves changing position to switch towers, the regenerated tower must
position, allowing air flow to the right hand tower. During this time, the
be repressurized.
Right Tower Purge Valve is actuated to a closed position, preventing the
compressed air from venting to atmosphere. As the compressed air
flows through the desiccant material at pressure, removal of water vapor NOTICE
from the air stream begins to occur through adsorption. In the Failure to re-pressurize prior to tower switchover will result in shocking
adsorption process, the desiccant material draws water vapor out of the the desiccant material and cause premature desiccant dusting.
compressed air and "holds" it until the right tower drying cycle is
complete. Compressed air flows out of the tower for delivery to the Repressurization is accomplished by closing the appropriate Purge
process use. The Outlet Flow Check Valves provide air flow diversion Valve. Closing the Purge Valve allows the regeneration air to begin to
to the outlet air connection of the dryer. The Right Outlet Flow Check pressurize the tower. In addition to the regeneration air, the
Valve allows air flow through to the outlet connection of the dryer while Repressurization Valve, (standard on -100F dew point and high
The Left Outlet Flow Check Valve checks off to prevent flow back to the pressure dryers) opens allowing some additional air from the outlet of
regenerating tower. the dryer to ensure adequate pressurization. During normal tower
regeneration, the Repressurization Valve is held closed so that the only
7.3 REGENERATION CYCLE source of air for regeneration passes through the purge adjustment
Previously adsorbed moisture, removed from the process stream, gets assembly.
stripped or desorbed from the desiccant material in the regeneration
process. The first stage of regeneration is tower depressurization. After 7.6 VALVES
the Inlet Flow Valves are switched to divert air flow away from the Solenoid control valves are used to actuate the Flow Valves, Purge
regenerating tower, the appropriate Purge Valve will be opened and the Valves and the optional Repressurization Valve on Heatless Dryers. The
tower will be depressurized. Through rapid depressurization, a Inlet Flow Valves and optional Repressurization Valve are normally open
significant portion of the previously adsorbed water vapor is stripped off valves, while the Purge Valves are connected as normally closed valves.
of the desiccant material and exhausted to atmosphere. This arrangement permits air to flow through the dryer during periods of
loss of power.
The second stage of regeneration uses a portion of the dry, compressed
air, expanded to atmospheric pressure to complete the desorption Outlet Check Valves are single direction check valves that will allow flow
process. As shown on the FLow Diagram, the compressed air exits the in the direction shown on the Flow Diagram, but not allow flow in the
drying tower and a portion of the air flows through the Purge Adjustment opposite direction.
Valve and the Purge Orifice. Once the air has passed through Purge
Orifice, it expands to atmospheric pressure and continues the 7.7 TIMING SEQUENCE
regeneration process. Desorption occurs as the desiccant releases All timing functions are controlled by the Microprocessor Controller.
water vapor into the regeneration air and is exhausted through the Timing for HL Series dryers is as follows:
Purge Muffler.
7.7.1 TIMING CYCLE FOR -40F DEW POINT DRYERS
Heatless dryers are equipped with the ability to use air from a
downstream source to purge the regenerating towers. This feature is The standard timing cycle for -40F operation switches the
useful for applications with downstream (dry) storage tanks, as pulling Inlet Flow Valve position every five minutes which alternates
air from a downstream source can minimize cycling of the air the drying tower. At the same time as a tower Inlet Valve
compressor. opens, the appropriate tower Purge Valve opens to
depressurize the regenerating tower. Tower regeneration
7.4 SETTING THE REGENERATION AIR FLOW occurs for 4 minutes and 15 seconds, at which time the Purge
Valve closes to initiate repressurization.
Proper setting of the purge is necessary to achieve proper dryer
performance. Setting the purge flow too high will waste compressed air
and if set too low, the dryer will not achieve proper dew point
performance.
PRESS ON
BUTTONS
ON RESET
Initiates PLC program. Begins system monitoring and valve Pressing once clears the local alarm indication and de-energizes
switching functions. the remote alarm contact for many alarm conditions. Should the
alarm condition persist, the alarm will return after the alarm inhibit
OFF time has expired.
Stops PLC program. Stops valve switching functions. Initiates
shutdown sequence. Opens Inlet Flow Valves. Closes Purge SET
Valves. Permits the adjustment of parameters in FACTORY MODES.
+/- TEST
Allows user to modify set point values. Set point values cycle Not used in Desiccant Dryer applications
through a fixed range. Also allows entering negative numbers in
Factory Modes. i
Restricted Level access for factory use only.
or blank button
Allows user to step backwards to the previous level of the menu.
The status panel provides clear indication of dryer status via bright
LED indicators. The following illustration summarizes the panels
features:
7.8.2 MICROPROCESSOR CONTROL DISPLAY PARAMETERS in the screen and the remote alarm contact will close. Note
The Microprocessor Controller is capable of displaying a that during the alarm condition, the SELECT DISPLAY button
number of system parameters. The following summarizes the may be depressed to scroll through the available parameters.
parameters that can be accessed by depressing the SELECT After approximately 30 seconds, the alarm screen will
DISPLAY button from the Microprocessor Controller. (Note reappear, provided the alarm condition persists.
that some displays are optional and may not appear on all
models): Fail to Shift Alarm (OPTIONAL) - (FAIL TO SHIFT)
Pressure switches are provided to detect the pressure within
Tower Status {LT DRY / RT REGEN or LT REGEN / RT each tower. At 0 psig the switches are normally closed
DRY}: Provides visual confirmation of tower drying and which sends a signal to the controller. When the towers
regenerating status. pressurize, the switches open, thus removing the signal to
Step Timer {ie STEP 4 TIME 120}: Information screen the controller. During the cycle, the Microprocessor
displaying the current step in the program and the time Controller interrogates the pressure switches to determine
remaining for the displayed step. their current position. The Microprocessor Controller
compares their position to a look-up table within the
Dew Point Temperature (OPTIONAL) - {DEW POINT program. If the position of either switch differs from the
TEMP: XX}: When equipped with the Energy Management switchs proper position, the dryer will initiate the Fail to Shift
System (EMS) feature, provides accurate display of dryer Alarm.
outlet pressure dew point.
Purge Status (OPTIONAL) - {PURGE / NO PURGE}: High Dew Point Alarm (OPTIONAL) - (HIGH DEW POINT)
Indicates whether unit is currently consuming purging air. When the heatless dryer is equipped with the optional EMS
Requires EMS. feature, a sensor is provided that senses the outlet pressure
Alarms {ALARM LIST - PRESS ENTER}: Depressing dew point of the air and displays the value on the
<ENT> at this prompt permits viewing of current alarm status Microprocessor Controller. For dryers equipped with the
and alarm history. optional EMS feature, the sensor is used to detect a high dew
Operating & Purge Times - {OPERATING TIMES - PRESS point condition and displays the alarm as High Dew Point.
ENTER}: Depressing <ENT> at this prompt provides access
to the operating and purge hours of operation. Alarm List
The Microprocessor Controller stores the 20 most recent
Operating Mode {OPERATING MODE: HEATLESS}:
alarm conditions. These alarms are stored with the type of
Indicates mode of operation for dryer.
alarm as well as the date and time the alarm occurred. This
list can greatly facilitate troubleshooting the dryer and provide
7.8.3 ALARMS AND THEIR FUNCTIONS an indication of dryer operation during unattended service.
There are several alarms detected by the Microprocessor The following describe the method to access and review the
Control to alert the user of an out of tolerance condition. Once alarms stored in the Microprocessor Controller:
each alarm is detected, a description of the alarm will appear
Depressing the ENTER button enters the ALARM LIST ALARM LIST
menu.
PRESS ENTER
Alarm Condition
Adjusting the purge cycle to correlate with the operation of the air
compressor minimizes the potential for the air compressor to cycle and
saves the energy associated with generating unnecessary purge air.
NOTICE If the dryer has been shipped with desiccant packaged separately,
The standard dryer is not rated for any gas other than air. install the desiccant after locating and mounting. Desiccant has been
provided separate to minimize handling difficulty and placing
Operating pressure of Ingersoll Rand dryers can range from 75 -150 unnecessary stress on the dryer assembly
PSIG. Air available for your usage will vary with operating pressure. The
maximum design pressure of the Ingersoll Rand Heatless Dryer is 150 Bolt the dryer to the foundation using the bolt holes provided in the base
PSIG. For units required for higher operating pressures, consult your frame. Anchor bolts should project a minimum of 3.5 inches above the
Ingersoll Rand representative. foundation. Refer to General Arrangement drawing for details.
The dryer must never be installed where air and/or ambient temperature 9.3 PIPING
exceeds 120F or drops below +50F. Locate dryer to avoid extremes of Pipe the compressed air lines to the inlet and outlet connections. Locate
heat and cold from ambient or other conditions. Avoid locating dryer the pre-filters as close as possible to the dryer. Ensure the positioning
outside or where it is exposed to the elements. allows for ease of servicing. Refer to the General Arrangement drawing.
NOTICE Note that the wet air inlet is at the dryers lower manifold, while the dry
Ingersoll Rand recommends that the mufflers be cleaned after initial air outlet is at the dryers upper manifold. In situations where air supply
start-up to remove any desiccant dust generated during shipment. is required 24 hours a day (it is undesirable to interrupt the airflow), a
After running dryer for initial 30 minute period, de-energize / three valve by-pass system is recommended to bypass the dryer. Use
depressurize dryer and remove mufflers. Disassemble and clean the the fewest elbows necessary to keep pressure drop at a minimum.
removable insert inside the muffler core. Reinstall mufflers prior to
operating dryer. Once all piping has been connected, all joints including those on the
dryer, should be soap bubble tested at line pressure to ensure no joints
have been damaged in transit and site placement.
TRANSMITTER CABLE
SECURING SCREW
TRANSMITTER CABLE
TRANSMITTER
WASHER
SENSING BLOCK
9.6 ELECTRICAL CONNECTION Slowly open the outlet valve to gradually pressurize the down stream
Make all electrical connections to the dryer as shown on the wiring piping
diagram. Care must be taken in connecting the proper voltages.
NOTICE
NOTICE When opening the outlet valve, insure drying tower gauge maintains
Dryer must be grounded with the full sized ground wire connected to line pressure. Allowing pressure to drop in the dryer will result in an
an earth ground. overflow condition.
NOTICE NOTICE
Dryer must be fused according to NEC with the size fuse listed on the -100 F dryers require flow through the dryer to lower the pressure dew
dryer serial nameplate, or on specification sheet in technical manual. point to design levels. Failure to permit air flow through dryer
(deadheading) will result in elevated outlet dew points. Once air is
Size field connection knock-out for the conduit fitting required by the NEC. permitted to flow through the dryer, the pressure dew point will
gradually reduce to design levels.
9.7 DESICCANT LEVEL VERIFICATION
Remove desiccant fill port and the top of the desiccant vessel and 9.9 SHUT-DOWN SEQUENCE
check desiccant level. The level should be consistent with the level
depicted on the Desiccant Fill Chart at the end of the manual. The initial
charge of desiccant is installed in the dryers at the factory on models NOTICE
HL 2700 and smaller. Prior to removing power or compressed air from the dryer, depress the
OFF button on the Microprocessor Control This initiates the Shutdown
9.8 START-UP Sequence, which closes the purge valves, repressurizes the off-line
Slowly pressurize the dryer. When the dryer reaches full operating tower and opens the flow valves. DO NOT REMOVE POWER OR
pressure, check the system for air leaks. Soap test all joints and fitting. COMPRESSED AIR FROM THE DRYER DURING THE SHUTDOWN
To maintain desired dew point, any leaks detected must be fixed, SEQUENCE.
especially those on the outlet side of the dryer.
Maintain a compressed air source to the dryer and a supply of
Make sure that the purge adjustment valve is open and air outlet shut power to the Microprocessor Controller.
off valve (if equipped) is closed.
For dryers equipped with EMS, remove the dew point monitor sensor from
the electrical enclosure and install in the sensing block, located beside the
enclosure and attach the sensor cable to the sensor. SHUTDOWN
OFF
Turn on dryer disconnect switch (supplied by customer) to apply
SEQUENCE
power to the dryer. The LCD display on the Microprocessor Controller
will illuminate. Depress the OFF button to initiate the SHUTDOWN
SEQUENCE.
Start dryer by depressing the ON button on the Microprocessor
Controller. Permit the dryer to complete the full SHUTDOWN SEQUENCE (30
seconds)
For the first 30 seconds that the dryer is energized, both purge valves
will remain closed. After 30 seconds, the left tower purge valve will be
opened and depressurization of the left tower will occur. PRESS ON
With a voltmeter, check the power connections for the correct voltage
shown on the dryer serial nameplate.
Once the PRESS ON Prompt is displayed, the dryer has
Close and secure all electrical panel covers. completed the SHUTDOWN SEQUENCE. Power and air
may be safely removed from the dryer.
The Microprocessor Controller will indicate that the left tower is drying.
The dryer will operate in the sequence described in Section 7. De-energize the dryer
Following depressurization, adjust purge valve as described in Section 7.4 Shut down air compressor or bypass dryer
If the dryer has been in storage or off for an extended period of time,
the Blue Moisture Indicator may be gray, the High Dew Point Alarm (if
equipped) may be activated and the dew point display (if equipped)
may indicate a high dew point. Depending upon the duration of idle
time, it may take anywhere from one to twelve hours for the alarm
condition to go out, the BMI to return to its normal blue state and the
dew point to drop.
Parameter Display Set Point Depressing SELECT DISPLAY scrolls through the available
parameters.
DEW POINT ADJUSTER
PDP ADJUSTER -40, -4, +38
SETTING
ENERGY MANAGEMENT 10.2 DEW POINT ADJUSTER (-40 F DRYERS ONLY)
EMS OFF , ON
SYSTEM (OPTIONAL)
Dew point adjuster allows the user to select between -40 F, -4 F and
ENERGY MANAGEMENT SYSTEM +38F pressure dew points. Selecting a higher (wetter) pressure dew
EMS SET POINT -76 - +68
SETPOINT (OPTIONAL) * point lengthens the drying cycle, making the regeneration process
RESTART MODE RESTART LAST, ZERO commence less frequently than at lower (dryer) dew points. This results
in energy savings by depressurizing the system less times per hour.
PURGE FLOW ADJUSTER PURGE
30% - 100% The chart below describes the available outlet pressure dew points that
SETTING ADJUSTER
may be selected along with their respective cycle times.
COMPRESSOR INTERLOCK COMP
OFF , ON
SETTING INTERLOCK ISO 8573.1 Pressure Cycle Regenerations
HIGH DEW POINT ALARM HIGH DEW Class Dew Point Length per hour
OFF , ON
ACTIVATION (OPTIONAL) POINT 2 -40 F -40 C 10 min 12
3 -4 F -20 C 16 min 7.5
In TECHNICIAN MODE, the following parameters can be viewed but 4 +38 F +3 C 24 min 5
not changed:
The following illustrates the method of accessing and adjusting the dew
Parameter Display point adjuster feature
OPERATION MODE HEATLESS
SELECT
EMS: OFF 1 EMS SET POINT
DISPLAY
-41_
Depress the SELECT DISPLAY button until the ENERGY Use the numbers on the keypad to enter the desired
MANAGEMENT SYSTEM screen is displayed. pressure dew point temperature for the EMS setpoint.
+
- EMS: ON EMS SET POINT
ENTER
-41
Depress the +/- button until the desired set point is displayed.
Pressing SELECT DISPLAY saves the current selection. Depressing ENTER saves the selected set point.
SELECT
EMS SET POINT HL Dryers can be configured to restart in one of two operating modes.
As described in Section 5, the dryer may be configured for Manual
DISPLAY -43 operation (factory default) or Auto Restart, which permits the dryer to
restart automatically once power is re-applied to the dryer. The
Depress the SELECT DISPLAY button until the EMS SET following illustrates the method of accessing and adjusting the different
POINT screen is displayed. start modes for the dryer:
10.5 PURGE FLOW ADJUSTER 10.7 HIGH DEW POINT ALARM (INCLUDED WITH EMS OPTION)
Purge flow adjuster allows the user to reduce the duration of the purge 10.7.1 DESCRIPTION AND ACTIVATION
cycle to more closely match the inlet conditions to the dryer. This feature The purpose of the High Dew Point Alarm is to provide the
is well suited for applications where the dryer is consistently operator an alarm indication should the equipment fail to
underflowed, allowing only the required amount of purge air to be used. supply air at its designed pressure dew point. The EMS dew
The purge flow adjuster feature allows the user to select the relative point sensor communicates the pressure dew point reading to
duration of the purge cycle, from 30% to 100%, in 10% increments. the Microprocessor Controller. Should the pressure dew point
rise above the alarm set point, the Microprocessor Controller
The following illustrates the method of accessing and adjusting the will display the alarm condition on the controller screen.
purge flow adjuster feature
The following illustrates the method of activating the High
Dew Point Alarm feature:
SELECT
PURGE ADJUST
DISPLAY % PRG SELECT 100
SELECT
HIGH DEW PT
Depress the SELECT DISPLAY button until the PURGE DISPLAY OFF
FLOW ADJUSTER screen is displayed.
Depress the SELECT DISPLAY button until the HIGH DEW
POINT screen is displayed.
+ PURGE ADJUST
-
% PRG SELECT 70 HIGH DEW PT
+
-
Depress the +/- button until the desired percent purge is ON
displayed. Pressing SELECT DISPLAY saves the current
selection. Depress the +/- button until the desired set point is
displayed. Pressing SELECT DISPLAY saves the current
selection.
NOTICE
On dryers equipped with the optional Energy Management System
feature, the purge flow adjuster MUST be set to 100% in order for the 10.7.2 SETPOINT ADJUSTMENT
Energy Management System to operate properly.
On dryers equipped with the optional EMS, the High Dew
Point Alarm setpoint can be adjusted.
10.6 COMPRESSOR INTERLOCK
Compressor Interlock adjusts the operation of dryer to purge only when The following illustrates the method of adjusting the setpoint
the air compressor is LOADING or ON. This feature requires the for the High Dew Point Alarm feature:
customer to provide a relay on the air compressor to indicate whether
the air compressor is LOADING or ON vs. UNLOADING or OFF. Prior
to using this feature, the user must wire the relay to the 5V DC terminal
strip in the dryers electrical enclosure. The dryer will provide the 5V DC SELECT
HI PDP SETPOINT
power. The air compressor ON or LOAD signal should correspond with DISPLAY -10
the relay being open. The OFF or UNLOAD signal must correspond to
the relay being closed.
Depress the SELECT DISPLAY button until the HIGH DEW
POINT ALARM SET POINT screen is displayed.
With the Compressor Interlock properly set-up and activated, the dryers
purge valves will close when the air compressor is not making air, as
indicated by the OFF or UNLOAD condition. With the purge cycle
corresponding to the demands of the air dryer, cycling of the air HI PDP SETPOINT
compressor is minimized and energy savings is realized by only purging SET
when the air system requires.
___
The following illustrates the method of accessing and adjusting the Pressing the SET button permits the value of the HIGH DEW
Compressor Interlock feature: POINT ALARM SET POINT to be changed
SELECT
COMP INTERLOCK + HI PDP SETPOINT
DISPLAY OFF -
-___
Depress the SELECT DISPLAY button until the To enter a negative number, depress the +/- button.
COMPRESSOR INTERLOCK screen is displayed. Otherwise, proceed to the next step.
+
COMP INTERLOCK
- ON
Depress the +/- button until the desired set point is displayed.
Pressing SELECT DISPLAY saves the current selection.
Use the numbers on the keypad to enter the desired Ingersoll Rand desiccant dryers are capable of remote communications
pressure dew point temperature for the HIGH DEW POINT via MODBUS. Refer to the document entitled, Microprocessor Control
ALARM setpoint. Modbus Communications Guide for details on communicating with the
Controller via MODBUS.
HI PDP SETPOINT
ENTER
-21
Depressing ENTER saves the selected set point.
Check that the pre-filter drain is operating properly and that there is no Replace Check Valves (Preventative)
condensate discharged from purge mufflers. Replace cartridges
sooner if necessary as required by differential pressure indicator. 11.2 PRE-FILTERS AND POST-FILTERS
Verify that pressure in purging tower is 10 PSIG or less. If higher, Pre-filters - The cartridges of the pre-filter must be changed as often
muffler replacement is recommended. (Section 11.4) as required to prevent contamination of the regenerative dryer's
desiccant bed.
Verify that pre-filter and post-filter differential pressure is within
operating limits. Change as required. (Section 11.2). Replace
cartridges sooner if necessary as required by differential pressure The pre-filter and automatic drain must be checked daily. To prolong
indicator. filter cartridge life, it is recommended that a mechanical air / moisture
separator be placed immediately before the pre-filter.
Check the Blue Moisture Indicator. Make sure air is bleeding through
the indicator. The indicator will be blue when air is dry.
NOTICE
SEMI-ANNUAL MAINTENANCE FUNCTIONS: Should the drying system be overloaded and/or malfunctioning,
Check outlet dew point. causing high pressure drop, post-filters will prematurely plug. This
Check pilot air filter element and clean or replace as required. problem can be avoided by frequent inspection and proactive
replacement of cartridges.
Replace pre-filter and post-filter elements and / or cartridges. Replace
cartridges sooner if necessary as required by differential pressure
Post-filters - The purpose of the post-filter is to remove residual
indicator.
desiccant dust. Depending upon equipment application and usage,
frequency of filter element change will vary. It is recommended to
ANNUAL MAINTENANCE FUNCTIONS:
change filter element every six months as a minimum.
Check desiccant and replace if necessary.
Inspect and clean pilot air control no-loss drain valves, check valves WARNING
and diaphragm valves. Rebuild and / or replace as required.
Test lights and switches, replace as necessary. To avoid injury, depressurize dryer before performing any service.
Test electrical components, replace as necessary.
CAUTION
Depressurize the dryer turn control power off.
Be sure to wear respiratory protection during the draining and filling
Replace muffler.
process to minimize inhalation of desiccant, as desiccant will produce
Follow Start-up procedure described in Section 9.7. dust during this procedure.
Turn control power back on.
NOTICE
11.5 PURGE AND SWITCHING DIAPHRAGM VALVES (HL90 - HL
2700) Each dryer is shipped with a desiccant sample kit to allow the
desiccant to be sent for analysis. This kit can be used to have the
These valves have two control ports; one on top and the other on the condition of the desiccant verified by laboratory analysis. Please follow
back side. the instructions found in the kit.
Normally Open (N.O.) Valves: For N.O. inlet or repressurization valves, The standard units are furnished with fill and drain ports on each
control air is supplied to the top port. The back side port exhausts out desiccant tower. Remove the caps on both ports.
the bottom side of the diaphragm. If air leaks continuously when To assist in getting the desiccant to flow from the tower, insert a small
control air is supplied to the valve, the internal seals are leaking and rod in to the drain port as necessary. This may be required as the
must be replaced. desiccant is packed into the towers which may interfere with the
desiccant flow from the towers.
Normally Closed (N.C.) Valves: For N.C. purge valves, the top port is Retainer screens, located at the inlet and outlet piping connections of
plugged. Control air is supplied to the back port. If air vents out of the the tower, are removable on all models. It is suggested that these
back port continuously when the solenoid is de-energized, it will screens be removed and cleaned at the time of desiccant changeout.
exhaust through the top of the solenoid. If this condition is observed, These screens can be accessed by disconnecting the upper and lower
the internal seals are leaking and must be replaced. manifolds from the dryer towers.
After cleaning the retainer screens, replace screens and reattach the
11.6 PILOT OPERATED ACTUATOR (HL3300 - HL5000) outlet port plug.
Should the actuator fail to rotate, disconnect the pilot lines to check if With the fill port plug removed, fill the dryer tower with the appropriate
the actuator is receiving pilot pressure. grade and size desiccant. The level of the desiccant should be below
If the actuator is receiving pressure: the top retainer screen as shown on the Desiccant Fill Chart below.
Once the towers have been filled, replace the fill port plug on each
Verify that control pressure is 75 psig min. tower.
Ensure the inlet valve is not plugged. Any connections disturbed in the desiccant changeout process should
be leak tested prior to re-commissioning the dryer.
MOLECULAR SIEVE
Model No. A B
HL90 20" 30" Model No. A B
HL120 7" 20.38" HL1000 14.5" 31.5"
HL160 18" 29.75" HL1200 4" 23.75"
HL200 7" 21.50" HL1500 6" 23.25"
HL250 16" 28" HL1800 31.50" 45.75"
HL300 7" 21.25" HL2100 22" 38.5"
HL2700 6" 26"
HL400 8" 22.25"
HL3300 16.25" 5.25"
HL500 20" 34.75"
HL4000 7.75" 29"
HL600 10" 27.50"
HL5000 9" 28"
HL800 27" 41"
Tolerance = +/- .50
DESICCANT FILL CHART
Elevated dew point Insufficient purge rate. Check purge flow settings.
Inlet air pressure below design condition. Check pressure source and system for leakage.
Flow rate higher than design condition. Check flow rate and cause for increased demand.
Correct flowrate condition.
Inlet temperature above design Check aftercooler, clean and service as necessary.
condition.(120F)
Entrained water entering desiccant bed. Check air/moisture separator and pre-filter. Replace
dryer desiccant if necessary.
Blue Moisture Indicator (BMI) Elevated dew point Refer to Elevated Dew Point corrective actions above.
indicates high moisture level.
BMI wet Depending on degree of saturation of the desiccant, the
BMI may take a week or more of continuous use to
switch back to its blue (dry) state.
Excessive pressure drop in Excessive flowrate. Check flow rate and cause for increased air demand.
dryer
Inlet pressure below design condition. Check pressure source.
No pilot air. Check pilot air line. Check that control air line filter is
clean.
Pilot-operated diaphragm valve seal failure Inspect and replace seals as required.
Dryer fails to pressurize. Faulty purge valve Check that repressurization circuit is sending control
signal.
Dryer depressurizes too rapidly. Purge valve does not close; dryer Check purge valve and its no-loss drain valve.
repressurizing through inlet valve.
Dryer fails to purge. Purge valve does not open. Purge valve stuck Check purge valve and its no-loss drain valve. Repair
in closed position. and replace if necessary.
Excessive back pressure in Purge muffler does not pass air. Purge muffler is dirty; replace.
regenerating tower (above 5
psig) Purge muffler passes too much air. Air is Check inlet valve and outlet check valves. Verify inlet
leaking across valve. valve is closed to purging tower (0 psig tower).
Right tower excessively high Improper calibration. Reset when right tower is on line.
pressure at the purge gauge.
16
14
10
0
0 10 20 30 40 50 60 70
22 35
20
30
18
16 25
14
12 20
10 15
8
6 10
4
5
2
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Purge Meter Setting - psig Purge Meter Setting - psig
60
45
55
40 50
Purge Air Flow - SCFM
35 45
Purge Air Flow - SCFM
30 40
35
25
30
20 25
15 20
15
10
10
5 5
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Purge Meter Setting - psig Purge Meter Setting - psig
70 90
65
80
60
55 70
Purge Air Flow - SCFM
50
45 60
40 50
35
30 40
25 30
20
15 20
10
10
5
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Purge Meter Setting - psig Purge Meter Setting - psig
130
130
120
120
110
110
100
100
90
90
80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Purge Meter Setting - psig Purge Meter Setting - psig
180 220
200
160
180
Purge Air Flow - SCFM
140
160
Purge Air Flow - SCFM
120 140
100 120
80 100
80
60
60
40
40
20 20
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Purge Meter Setting - psig Purge Meter Setting - psig
300
360
270
330
240
Purge Air Flow - SCFM
300
Purge Air Flow - SCFM
210 270
180 240
210
150
180
120 150
90 120
60 90
60
30
30
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Purge Meter Setting - psig Purge Meter Setting - psig
360 500
330 450
300
400
270
350
240
210 300
180 250
150 200
120 150
90
100
60
30 50
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Purge Meter Setting - psig Purge Meter Setting - psig
350
500
300
400
250
200 300
150 200
100
100
50
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Purge Meter Setting - psig Purge Meter Setting - psig
900 900
P u rg e A ir F lo w - S C F M
800 800
Purge Air Flow - SCFM
700 700
600 600
500 500
400
400
300
300
200
200
100
100
0
0 10 20 30 40 50 60 70 0
0 10 20 30 40 50 60 70
Purge Meter Setting - psig
Purge Meter Setting - psig
10.19
CL OF AIR OUTLET
(4) .56'' DIA. MTG. HOLES
CL OF AIR OUTLET
DUST PARTICULATE
AFTERFILTER
TOWER PRESSURE ELECTRICAL ENCLOSURE PURGE ADJUSTMENT VALVE
GAUGE NEMA 4
CONTROLLER & DISPLAY PANEL
(SEE DETAIL) PURGE FLOW GAUGE 1/4'' MPT AUTOMATIC DRAIN
CONNECTION
BLUE MOISTURE
INDICATOR RELIEF VALVE
HIGH EFFICIENCY
PILOT AIR FILTER
PILOT AIR SHUT-OFF
CL OF AIR INLET 1'' FPT AIR INLET
VALVE CONNECTION
1/4'' MPT AUTOMATIC DRAIN HIGH EFFICIENCY
CONNECTION 56.56 PREFILTER
http://www.ingersollrandproducts.com
CONNECTION
40.50 11.00
10.19 17.38
32.50
19.81
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
5) DRYER TO BE LIFTED BY LIFTING SUPPORT ONLY.
GENERAL ARRANGEMENT
HL90-HL120
580000-E
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF
2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING
4) LEFT/RIGHT TOWER REGEN LEFT TOWER DRYING LIGHT
5) DEW POINT (OPTIONAL)
FACE OF AIR INLET & OUTLET 6) REGEN SEQUENCE STATUS
(OPTIONAL 3-VALVE BYPASS) 8) COMPRESSOR INTERLOCK (OPTIONAL) DRYER OFF / ALARM LIGHT
9) AUTO RESTART
2.00 TYP RIGHT TOWER REGEN LIGHT
PUSH BUTTONS RIGHT TOWER DRYING LIGHT
1) ON
2.00 (TYP) 2) OFF
3) RESET
32.56 4) TEST
5) SET
CONTROLLER & DISPLAY PANEL DETAIL
6) SELECT DISPLAY
43.75 7) ENTER
8) +/-
28.00
32.00
11.19
CL OF AIR OUTLET
34.50 FACE OF AIR OUTLET
(4) .56'' DIA. MTG. HOLES 1 1/2'' FPT AIR OUTLET
10.25 CONNECTION
20.00 (HL 200)
19.00 (HL 160)
1 1/2'' FPT AIR INLET
DESICCANT FILL PORT CONNECTION
CL OF AIR OUTLET
ELECTRICAL
TOWER PRESSURE GAUGE ENCLOSURE PURGE ADJUSTMENT VALVE
NEMA 4
CONTROLLER & DISPLAY PANEL DUST PARTICULATE
(SEE DETAIL) PURGE FLOW GAUGE
AFTERFILTER
1/4'' MPT AUTOMATIC DRAIN
BLUE MOISTURE CONNECTION
INDICATOR
RELIEF VALVE
PILOT AIR FILTER
CL OF AIR INLET
1/4'' MPT AUTOMATIC DRAIN
CONNECTION
59.50
66.12 HIGH EFFICIENCY
PREFILTER
http://www.ingersollrandproducts.com
HL Series Desiccant Dryer Models 90-5000
1/4'' MPT AUTOMATIC DRAIN
PURGE MUFFLER CONNECTION
34.00
14.0 GENERAL ARRANGEMENT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
GENERAL ARRANGEMENT
HL160-HL200
580001-D
23
24
FACE OF AIR INLET & OUTLET LCD DISPLAY POWER ON LIGHT
(OPTIONAL 3-VALVE BYPASS) 1) DRYER ON/OFF
2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
2.00 TYP 5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
2.00 TYP
RIGHT TOWER REGEN LIGHT
PUSH BUTTONS RIGHT TOWER DRYING LIGHT
1) ON
44.19 @ HL 250 2) OFF
50.38 @ HL 300 3) RESET
4) TEST
5) SET CONTROLLER & DISPLAY PANEL DETAIL
28.00 32.00 6) SELECT DISPLAY
7) ENTER
8) +/-
10.69
CL OF AIR OUTLET
DUST PARTICULATE
AFTERFILTER
TOWER PRESSURE ELECTRICAL
GAUGE ENCLOSURE PURGE ADJUSTMENT VALVE
NEMA 4
CONTROLLER & DISPLAY PANEL PURGE FLOW GAUGE
(SEE DETAIL)
1/4'' MPT AUTOMATIC DRAIN
CONNECTION
BLUE MOISTURE
INDICATOR RELIEF VALVE
PILOT AIR FILTER
PILOT AIR SHUT-OFF
VALVE
1/4'' MPT AUTOMATIC DRAIN CL OF AIR INLET AIR INLET CONN.
CONNECTION 1 1/2'' FPT @ HL 250
2'' FPT @ HL 300
60.00
66.81
http://www.ingersollrandproducts.com
HIGH EFFICIENCY
PREFILTER
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
GENERAL ARRANGEMENT
HL250-HL300
580002-D
38.50
LCD DISPLAY
1) DRYER ON/OFF POWER ON LIGHT
FACE OF AIR INLET & OUTLET 2) DRYER ALARM LEFT TOWER REGEN LIGHT
(OPTIONAL 3-VALVE BYPASS) 3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
50.94 2.00 TYP
32.00
11.19
CL OF AIR OUTLET
BLUE MOISTURE
INDICATOR RELIEF VALVE
1/4'' MPT AUTOMATIC
PILOT AIR FILTER DRAIN CONNECTION
L
1/4'' MPT AUTOMATIC DRAIN CL OF AIR INLET 2'' FPT AIR INLET
CONNECTION CONNECTION
60.25
67.81
HIGH EFFICIENCY
PREFILTER
http://www.ingersollrandproducts.com
HL Series Desiccant Dryer Models 90-5000
34.00
1/4'' MPT AUTOMATIC
DRAIN CONNECTION
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
GENERAL ARRANGEMENT
HL400
580003-D
25
26
40.50 LCD DISPLAY
1) DRYER ON/OFF POWER ON LIGHT
2) DRYER ALARM LEFT TOWER REGEN LIGHT
FACE OF AIR INLET & OUTLET 3) LEFT/RIGHT TOWER DRYING
(OPTIONAL 3-VALVE BYPASS) 4) LEFT/RIGHT TOWER REGEN LEFT TOWER DRYING LIGHT
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
2.00 TYP
RIGHT TOWER REGEN LIGHT
54.50 @ HL500 PUSH BUTTONS RIGHT TOWER DRYING LIGHT
57.25 @ HL600 1) ON
2.00 (TYP) 2) OFF
(4) O .56 MOUNTING HOLES
3) RESET
4) TEST
5) SET CONTROLLER & DISPLAY PANEL DETAIL
6) SELECT DISPLAY
7) ENTER
8) +/-
29.00 33.00
12.19
CL OF AIR OUTLET
FACE OF AIR OUTLET
11.50
27.50 @ HL 500
30.25 @ HL 600 2'' FPT AIR OUTLET
CONNECTION
CL OF AIR OUTLET
HIGH EFFICIENCY
PREFILTER
http://www.ingersollrandproducts.com
HL Series Desiccant Dryer Models 90-5000
40.00 1/4'' MPT AUTOMATIC
DRAIN CONNECTION
12.19 20.81
17.00
27.50 @ HL 500
56.50 30.25 @ HL 600 40.50
FACE OF AIR INLET CL OF AIR INLET
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
GENERAL ARRANGEMENT
HL500-HL600
580004-D
FACE OF AIR INLET & OUTLET
(OPTIONAL 3-VALVE BYPASS)
9.62 PURGE ADJUSTMENT VALVE
2.00 TYP
(4) .56''O MOUNTING HOLES 44.00 3.00 TYP FACE AIR OUTLET CL OF AIR OUTLET
CL AIR OUTLET
ELECTRICAL
ENCLOSURE
NEMA 4
http://www.ingersollrandproducts.com
DRAIN CONNECTION
PILOT AIR FILTER
69.25 PURGE
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
GENERAL ARRANGEMENT
HL800-HL1200
580005-E
27
28
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF
2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
ELECTRICAL
ENCLOSURE CL OF AIR OUTLET
NEMA 4
RELIEF VALVE
TOWER PRESSURE
GAUGE
BLUE MOISTURE
INDICATOR
PURGE MUFFLER
PILOT AIR
SHUT-OFF 80.06 PILOT AIR FILTER
VALVE PURGE FLOW
GAUGE
56.88
http://www.ingersollrandproducts.com
CL OF AIR INLET
DRAIN PORT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
GENERAL ARRANGEMENT
HL1500
580006-D
LCD DISPLAY
1) DRYER ON/OFF POWER ON LIGHT
2) DRYER ALARM
3) LEFT/RIGHT TOWER DRYING LEFT TOWER REGEN LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL) LEFT TOWER DRYING LIGHT
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
(4) .56''O MOUNTING HOLES 54.00 3.00 2.00 TYP 22.38 CL OF AIR OUTLET 4'' 150# R.F. FLANGE
TYP AIR OUTLET CONNECTION
OUTLET CHECK OUTLET CHECK
38.12 FACE OF OUTLET VALVE VALVE
CONTROLLER AND
2'' NPT PLUG DISPLAY PANEL
DESICCANT (SEE DETAIL)
FILL PORT
CL OF AIR OUTLET
ELECTRICAL
ENCLOSURE
NEMA 4
PURGE CHECK
VALVE
PURGE CHECK
VALVE
TOWER PRESSURE
GAUGE RELIEF
BLUE VALVE
MOISTURE
91.88 INDICATOR
PURGE FLOW
GAUGE PURGE
PURGE ADJUSTMENT
MUFFLER VALVE
http://www.ingersollrandproducts.com
67.25
PILOT AIR
14.0 GENERAL ARRANGEMENT
SHUT-OFF
2'' NPT PLUG VALVE
26.12
DESICCANT
DRAIN PORT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
GENERAL ARRANGEMENT
HL1800-HL2100
580029-D
29
30
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF LEFT TOWER REGEN LIGHT
2) DRYER ALARM LEFT TOWER DRYING LIGHT
3) LEFT/RIGHT TOWER DRYING
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
60.75
RIGHT TOWER REGEN LIGHT
PUSH BUTTONS RIGHT TOWER DRYING LIGHT
43.00 47.00 1) ON
2) OFF
3) RESET
4) TEST
5) SET CONTROLLER & DISPLAY PANEL DETAIL
6) SELECT DISPLAY
7) ENTER
8) +/-
2.00 (TYP)
(4) .56''O MOUNTING HOLES
3.00 (TYP)
54.00
38.25 FACE OF OUTLET 22.38 CL OF AIR OUTLET 4'' FLANGE AIR
OUTLET CONNECTION
2'' NPT PLUG
DESICCANT
FILL PORT
91.88
PURGE
ELECTRICAL ADJUSTMENT
ENCLOSURE VALVE
TOWER PRESSURE NEMA 4
GAUGE RELIEF VALVE
BLUE
MOISTURE
INDICATOR PURGE FLOW
GAUGE
PURGE
MUFFLER
PILOT AIR
FILTER
67.25
http://www.ingersollrandproducts.com
CL OF AIR INLET
PILOT AIR
2'' NPT PLUG SHUT-OFF 26.12
DESICCANT VALVE
14.0 GENERAL ARRANGEMENT
DRAIN PORT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
GENERAL ARRANGEMENT
HL2700
580007-D
5.88
60.00
(4) .56''O MOUNTING HOLES 1.50 (TYP) PILOT AIR FILTER
63.00
CLOF OUTLET
66.00
6'' RAISED FLANGE 150#
41.38 FACE OF OUTLET AIR OUTLET CONNECTION
23.00
CHECK VALVE
DESICCANT
FILL PORT
CL OF AIR OUTLET
100.00
PURGE FLOW
BLUE MOISTURE GAUGE
INDICATOR CL OF AIR INLET
6'' FLUSH FLANGE 125#
http://www.ingersollrandproducts.com
72.25 AIR INLET CONNECTION
FLOW VALVE
34.00
14.0 GENERAL ARRANGEMENT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
5) FILTER PACKAGES SHIPPED SEPARATELY.
FILTER PIPING SUPPORT, IF REQUIRED, TO BE
SUPPLIED BY CUSTOMER.
GENERAL ARRANGEMENT
HL3300-HL4000
580092-E
31
32
12.00
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF
CL OF MOUNTING HOLE 2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
7) COMPRESSOR INTERLOCK
8) AUTO RESTART DRYER OFF / ALARM LIGHT
32.50
6.00 (TYP)
CL OF MOUNTING HOLE
PILOT AIR FILTER
60.00
(4) O .62 MOUNTING HOLES 1.50 (TYP)
63.00
ELECTRICAL
CONTROLLER AND ENCLOSURE CL OF AIR OUTLET
DISPLAY PANEL NEMA 4
(SEE DETAIL)
TOWER PRESSURE
GAUGE PURGE ADJUSTMENT
VALVE
TOWER RELIEF
VALVE
http://www.ingersollrandproducts.com
PURGE VALVE
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
5) FILTER PACKAGES SHIPPED SEPARATELY.
FILTER PIPING SUPPORT, IF REQUIRED, TO BE
SUPPLIED BY CUSTOMER.
GENERAL ARRANGEMENT
HL5000
580306-B
15.0 WIRING DIAGRAM
WIRING DIAGRAM
HL90-HL5000
TM-580078-C
FLOW DIAGRAM
HL90-HL2700
580022-E
FLOW DIAGRAM
HL3300-HL5000
580213-C
1 2 3
VALVE, BALL, CONTROL AIR, 1/4" 38054086 38054086 38054086 38054086 38054086 1
VALVE, SOLENOID, CONTROL AIR, 24VDC MINI 38053054 38053054 38053054 38053054 38053054 1
Spare. Quantities under this heading reflect the number of each item which we recommend be kept on hand for maintenance or repair.
The appropriate quantity for your application will depend on how critical interruptions in service are to your operation.
Class Quantity Suggested for
1 Minimum Domestic service where interruptions in service are acceptable.
2 Average Domestic service where some interruptions in service are acceptable.
3 Maximum Export service or for domestic service where interruptions in service are unacceptable.
Spare. Quantities under this heading reflect the number of each item which we recommend be kept on hand for maintenance or repair.
The appropriate quantity for your application will depend on how critical interruptions in service are to your operation.
Class Quantity Suggested for
1 Minimum Domestic service where interruptions in service are acceptable.
2 Average Domestic service where some interruptions in service are acceptable.
3 Maximum Export service or for domestic service where interruptions in service are unacceptable.
VALVE, BALL, PURGE ADJUST, 1 1/2" 38054052 38054052 38054052 38054052 38054052 1
VALVE, BALL, PURGE ADJUST, 2" - - - - - 1
VALVE, CHECK, PURGE, 1 1/2" 23354582 38052643 38052643 38052643 38052643 2
VALVE, CHECK, FLOW, 3" 38053484 38053484 38053484 38053484 38053484 2
VALVE, SAFETY/RELIEF 1/2" 38054060 38054060 38054060 - - 2
VALVE, SAFETY/RELIEF 3/4" - - - 38446506 38446506 2
VALVE, SOLENOID 24VDC MINI 38053054 38053054 38053054 38053054 38053054 1
Spare. Quantities under this heading reflect the number of each item which we recommend be kept on hand for maintenance or repair.
The appropriate quantity for your application will depend on how critical interruptions in service are to your operation.
Class Quantity Suggested for
1 Minimum Domestic service where interruptions in service are acceptable.
2 Average Domestic service where some interruptions in service are acceptable.
3 Maximum Export service or for domestic service where interruptions in service are unacceptable.
Spare. Quantities under this heading reflect the number of each item which we recommend be kept on hand for maintenance or repair.
The appropriate quantity for your application will depend on how critical interruptions in service are to your operation.
Class Quantity Suggested for
1 Minimum Domestic service where interruptions in service are acceptable.
2 Average Domestic service where some interruptions in service are acceptable.
3 Maximum Export service or for domestic service where interruptions in service are unacceptable.
VALVE DESCRIPTION VALVE CCN * SEAL KIT CCN HARDWARE KIT CCN
VALVE, DIAPHRAGM, 3/4" P.O.N.C. 38446894 38052114 38052635
VALVE, DIAPHRAGM, 1" P.O.N.C. 38052940 38052114 38052635
VALVE, DIAPHRAGM, 1-1/2" P.O.N.C. 38052932 38052668 38052825
VALVE, DIAPHRAGM, 2" P.O.N.C. 38053088 38052866 38052965
VALVE, DIAPHRAGM, 1" P.O.N.O. 38453833 38052114 38052619
VALVE, DIAPHRAGM, 1 1/2" P.O.N.O. 38052957 38052668 38052783
VALVE, DIAPHRAGM, 2" P.O.N.O. 38053070 38052866 38052882
VALVE, DIAPHRAGM, 3" P.O.N.O. 38052981 38053005 38053013
VALVE, DIAPHRAGM, 4" P.O.N.O. 38052924 38053021 38053039
* Refer to the list of individual parts at the beginning of the REPLACEMENT PARTS
section to determine which Valve listed in the above table is applicable to your dryer.
CCN's for the relevant Seal Kits and Hardware Kits will be found in the adjacent
columns.
EMS PARTS
DESCRIPTION CCN
VALVE DESCRIPTION VALVE W/ ACT VALVE ONLY VALVE REPAIR KIT ACTUATOR ACTUATOR KIT
MODEL Inlet Flow Inlet Flow Purge Width in. Depth in. w/o Depth in.w/ Height in (cm) Air In & Shipping Desiccant
-40 -100 Flow (cm) Bypass(cm) Bypass (cm) Out Weight lbs Weight per
Dewpoint Dewpoint SCFM Connec (kg) Dryer lbs (kg)
SCFM SCFM tion
HL90 90 72 14 40.5 (102.9) 30 (76.2) 37.5 (95.3) 63 12 (160.3) 1 475 (213) 100 (45)
HL120 120 96 19 40.5 (102.9) 30 (76.2) 37.5 (95.3) 63 12 (160.3) 1 563 (255) 134 (61)
HL160 160 128 26 44.5 (113) 32 (81.3) 43.75 (111.1) 66.12 (167.9) 1 1/2 707 (321) 192 (87)
HL200 200 160 30 44.5 (113) 32 (81.3) 43.75 (111.1) 66.12 (167.9) 1 1/2 731 (332) 236 (107)
HL250 250 200 40 48.5 (123.2) 32 (81.3) 44.19 (112.2) 66.81 (169.7) 1 1/2 869 (394) 290 (132)
HL300 300 240 48 48.5 (123.2) 32 (81.3) 50.38 (128.0) 66.81 (169.7) 2 924 (419) 344 (156)
HL400 400 320 65 52.5 (133.4) 36.19 (91.9) 50.94 (129.4) 67.81 (172.2) 2 1115 (506) 470 (213)
HL500 500 400 81 56.5 (143.5) 39.69 (100.8) 54.5 (138.4) 82.5 (209.6) 2 1564 (709) 638 (289)
HL600 600 480 93 56.5 (143.5) 42.4 (107.8) 57.25 (145.4) 82.5 (209.6) 2 1664 (755) 748 (339)
HL800 800 640 130 64 (162.6) 51.25 (130.2) 64.38 (163.5) 87.62 (222.6) 3 2017 (915) 900 (408)
HL1000 1000 800 162 64 (162.6) 51.25 (130.2) 64.38 (163.5) 87.62 (222.6) 3 2237 (1015) 1100 (499)
HL1200 1200 960 195 64 (162.6) 51.25 (130.2) 64.38 (163.5) 87.62 (222.6) 3 2424 (1100) 1270 (576)
HL1500 1500 1200 243 78 (198.1) 54.76 (139.1) N/A 80 (203.2) 4 2974 (1349) 1600 (726)
HL1800 1800 1440 292 84 (213.4) 60.62 (154.0) N/A 91.88 (233.4) 4 3905 (1771) 2000 (907)
HL2100 2100 1680 340 84 (213.4) 60.62 (154.0) N/A 91.88 (233.4) 4 4279 (1941) 2340 (1062)
HL2700 2700 2160 438 84 (213.4) 60.76 (154.3) N/A 91.88 (233.4) 4 4926 (2234) 2928 (1328)
HL3300 3300 2640 535 96 (244) 66 (167.6) N/A 100 (254) 6 2950 (1338) 3800 (1723) *
HL4000 4000 3200 649 96 (244) 66 (167.6) N/A 100 (254) 6 3000 (1361) 4226 (1917) *
HL5000 5000 4000 811 102 (259) 72 (183) N/A 92 (233.7) 6 3950 (1792) 5138 (2330) *
* Dryer weight shown does not include desiccant. Desiccant shipped separately.
Note: All above dryers rated at 150 psig, 120 F max inlet temperature.
Capacity and purge flow is basis standard inlet conditions (100 psig / 100 F) and will vary at different inlet conditions.
A NOTICE
Specification information above accurate at time of publication. Refer to equipment serial label
for actual specifications for units.
Les dessiccateurs dair sans chaleur dIngersoll Rand sont conus pour rapide dpressurisation initiale, une partie de lair assch par la tour en
adsorber lhumidit de lair comprim. Les dessiccateurs sont composs ligne traverse le lit de dessiccation et fait circuler lhumidit du lit vers
de deux tours, chacune contenant des lits de dessiccation, qui alternent lchappement du dessiccateur.
entre les modes en ligne (dessiccation) et hors ligne (rgnration),
produisant un dbit continu dair sec la sortie du dessiccateur. Ce processus continuel, alternant entre adsorption et dsorption est
contrl par un programmeur qui effectue la permutation entre les deux
En fonctionnement normal, lair humide circule dans la tour en ligne et tours, dans une squence spcifique programme. Des points de rose
la vapeur deau de lair est adsorbe (recueillie) sur les lits de dair comprim extrmement sec sont obtenus suite la permutation et
dessiccation. Pendant que lair est adsorb dans la tour en ligne, au fonctionnement continuels de ce dessiccateur. Ingersoll Rand offre
lhumidit du matriel dessiccant dans la tour hors ligne est limine au des dessiccateurs capables de produire de lair de sortie comprim dun
moyen dun procd appel dsorption (rgnration). Aprs une point de rose de -40 F ou -100 F.
3.0 GARANTIE
La socit Ingersoll Rand garantit que lquipement fabriqu et livr par LA SOCIT NE FAIT AUCUNE AUTRE GARANTIE OU
les prsentes ne comporte aucun dfaut de matriel ou de malfaon et DCLARATION DE QUELQUE SORTE QUE CE SOIT, DE NATURE
ce pendant une priode de douze (12) mois partir de la date de mise IMPLICITE OU EXPLICITE, SAUF EN CE QUI CONCERNE LE TITRE,
en service de lquipement ou de dix-huit (18) mois partir de la date ET ELLE RENONCE PAR LES PRSENTES TOUTE GARANTIE
de lexpdition de lusine, selon la premire ventualit. Pour se IMPLICITE DE QUALIT LOYALE ET MARCHANDE ET DAPTITUDE
conformer cette garantie, lacheteur sera tenu de signaler rapidement UN USAGE PARTICULIER.
et par crit la socit toute dfaillance survenue au cours de ladite
priode, aprs quoi la socit pourra soit corriger cette non-conformit La correction par la socit de tout vice, apparent ou cach, de la
par une rparation adapte au matriel, soit fournir une pice de manire et dans le dlai prciss ci-dessus, constituera
rechange FAB, pourvu que lacheteur ait stock, install, exploit et laccomplissement de toutes les responsabilits de la socit en vertu
entretenu lquipement conformment aux pratiques acceptes de de tout vice, quil sagisse dun contrat, dune ngligence de garantie,
lindustrie et quil ait suivi les recommandations particulires de la dindemnit, de responsabilit stricte ou autre en ce qui concerne
socit. Les accessoires et les quipements fournis par la socit mais lquipement ou ce qui en dcoule.
fabriqus par un tiers seront protgs par la garantie obtenue du tiers
par Ingersoll Rand, garantie qui sera ensuite cde lacheteur. La Lacheteur sengage ne pas faire fonctionner tout quipement
socit ne sera en aucun cas tenue responsable des rparations, considr comme tant dfectueux, sans dabord en avertir la socit
remplacements ou rglages effectus lquipement ou du cot de par crit de son intention de lutiliser. Une telle utilisation de
main-douvre engag par lacheteur ou par des tiers sans lautorisation lquipement est au risque et la responsabilit de lacheteur.
crite pralable de la socit.
Veuillez prendre note que la prsente garantie est la garantie standard
Les effets de la corrosion, de lrosion et de lusure normale sont de Ingersoll Rand. Toute autre garantie en vigueur au moment de
spcifiquement exclus. Les garanties de performance sont limites lachat de lquipement ou tablie comme faisant partie de la
celles spcifiquement cites dans la proposition de la socit. Sauf si sa commande pourra avoir prpondrance sur la prsente garantie.
responsabilit dans le respect de ces garanties de performance se limite
aux tests spcifis, les obligations de la socit se limiteront alors
assurer un correctif de la manire et dans les dlais prciss ci-dessus.
* Les dbits nominaux indiqus correspondent une temprature dadmission de 100F, une temprature ambiante de 100F et une pression dair
comprim de 100 psig.
AVIS
La nomenclature indique ci-dessus reprsente les options de fiche de prix standard. Dautres
options sont disponibles. Pour de plus amples dtails, reportez-vous linsert de nomenclature
spcifique votre dessiccateur.
5.1 INSPECTION Reportez-vous aux tiquettes sur le dessiccateur dair pour la mthode
la rception de votre dessiccateur dair Ingersoll Rand, veuillez inspecter utiliser pour soulever ou dplacer le dessiccateur. Lors du
lunit avec prcaution. Sil savre que le dessiccateur a t soulvement du dessiccateur, vrifiez quaucune contrainte nest
incorrectement manutentionn, veuillez le noter sur votre rcpiss au applique sur la tuyauterie ou lensemble des soupapes. Reportez-
destinataire, tout spcialement si le dessiccateur ne sera pas enlev de sa vous la section 9.2 pour lemplacement et le montage du
caisse tout de suite. Lobtention de laccord dment sign du garon livreur dessiccateur dair.
de tout dommage not facilitera toute demande dindemnisation future.
MISE EN GARDE
Il ne faut en aucun cas essayer de soulever des objets lourds sans
utiliser un quipement de levage appropri (cest--dire, grue, palan,
lingues ou chariot lvateur fourches). Le soulvement de tout
appareil sans lutilisation dun quipement de levage appropri peut
provoquer de srieuses blessures corporelles.
PRESS ON
TOUCHES
Touche ou vide
Permet lutilisateur de reculer vers le niveau prcdent du menu.
7.8.2 PARAMTRES DAFFICHAGE DU CONTRLEUR PAR tolrance. Une fois lalarme dtecte, une description de
MICROPROCESSEUR lalarme apparat lcran et le contact de lalarme distance
Le contrleur par microprocesseur peut afficher certains se ferme. Il faut noter que pendant la condition dalarme, la
paramtres systme. Ce qui suit rcapitule les paramtres touche SELECT DISPLAY peut tre enfonce pour faire
pouvant tre affichs en appuyant sur la touche SELECT dfiler les paramtres disponibles. Aprs environ 30
DISPLAY du contrleur par microprocesseur. (Il faudra noter secondes, lcran dalarme apparat nouveau condition
que certains affichages sont en option et peuvent ne pas que la condition dalarme persiste.
apparatre sur tous les modles) :
Alarme dchec de permutation (EN OPTION) - (FAIL TO
tat de tour {LT DRY / RT REGEN ou LT REGEN / RT DRY} SHIFT CHEC DE PERMUTATION) - Des pressostats
{DESSICATION GAUCHE /RGNRATION DROITE ou permettent de dtecter la pression dans chaque tour. une
RGNRATION GAUCHE / DESSICATION DROITE} : valeur de 0 psig, les pressostats sont normalement
Offre une confirmation visuelle des tats de dessiccation et ferms, ce qui envoie un signal au contrleur. Lorsque les
de rgnration de la tour. tours se mettent sous pression, les pressostats souvrent et
Programmeur dtape {STEP 4 TIME 120} (cest--dire le signal au contrleur est supprim. Pendant le cycle, le
TAPE 4 TEMPS 120) : cran dinformations affichant contrleur par microprocesseur interroge les pressostats
ltape en cours dans le programme et le temps restant pour pour dterminer leur position actuelle. Le contrleur par
ltape affiche. microprocesseur compare ces positions par rapport une
table de conversion dans le programme. Si la position de
Temprature de point de rose (EN OPTION) - {DEW lun ou lautre des pressostats est diffrente de la position
POINT TEMP (TEMP POINT DE ROSE) : XX} : Si lunit correcte du pressostat, le dessiccateur initialise alors une
est quipe dun systme de gestion dnergie EMS (SGE), alarme Fail to Shift.
permet doffrir un affichage prcis du point de rose de la
pression de sortie du dessiccateur. Alarme de point de rose lev (EN OPTION) - (HIGH DEW
tat de purge (EN OPTION) - {PURGE / NO PURGE} POINT POINT DE ROSE LEV) - Lorsque le
(PURGE / SANS PURGE) : Indique si lunit consomme dessiccateur sans chaleur est quip de la caractristique
actuellement de lair de purge. Ncessite EMS (SGE). EMS (SEG) en option, un capteur est utilis pour dtecter le
Alarmes {ALARM LIST - PRESS ENTER} (LISTE point de rose de pression de refoulement dair et la valeur
DALARME APPUYER SUR ENTER) : Appuyez sur est affiche sur le contrleur par microprocesseur. Pour les
<ENT> ce message dinvite pour visualiser ltat de dessiccateurs quips de la caractristique EMS (SEG) en
lalarme en cours et lhistorique dalarme. option, le capteur est utilis pour dtecter une condition de
Temps de fonctionnement et de purge - {OPERATING point de rose lev et une alarme High Dew Point (point
TIMES PRESS ENTER} (TEMPS DE de rose lev) est affiche.
FONCTIONNEMENT APPUYER SUR ENTER) : Appuyez
sur <ENT> ce message dinvite pour accder aux heures Liste dalarme
de fonctionnement et de purge. Le contrleur par microprocesseur peut mmoriser jusqu 20
conditions dalarme les plus rcentes. Ces alarmes sont
Mode dopration {OPERATING MODE (MODE mmorises avec le type dalarme ainsi que la date et lheure
DOPRATION) : HEATLESS} (SANS CHALEUR): Indique o lalarme sest produite. Cette liste peut normment
le mode dopration du dessiccateur. faciliter le dpannage du dessiccateur et fournir une indication
sur le fonctionnement du dessiccateur lors dune utilisation
7.8.3 ALARMES ET LEURS FONCTIONS sans surveillance. La procdure suivante sert accder et
rviser les alarmes mmorises dans le contrleur par
Il existe plusieurs alarmes dtectes par le contrleur par microprocesseur :
microprocesseur afin davertir lutilisateur dune condition hors
Condition dalarme
OPERATING TIMES
SELECT OPERATING TIMES PRESS ENTER
DISPLAY
PRESS ENTER
Appuyez sur la touche pour faire revenir le contrleur au
Appuyez sur la touche SELECT DISPLAY jusqu ce que mode CUSTOMER.
OPERATING TIMES (HEURES DE FONCTIONNEMENT)
soit affich lcran.
Une fois toute la tuyauterie raccorde, tous les joints y compris ceux sur 9.5 INSTALLATION DU TRANSMETTEUR DE POINT DE
le dessiccateur devront tre tests leau savonneuse la pression de
fluide afin dassurer quaucun joint na t endommag lors du transport
ROSEE (OPTION)
ou de linstallation sur site. Sur les scheurs munis du systme EMS, le transmetteur de point de
rose est expdi dans un colis spar l'intrieur du boitier
9.4 FILTRATION lectrique pour le protger pendant le transport. Avant d'utiliser le
Il est important que votre installation de dessiccateur prvoit lutilisation systme EMS, le transmetteur doit tre install sur le bloc 'Capteur'
dun pr-filtre et dun post-filtre. Tous les dessiccateurs en standard sont qui se trouve sur le cot ou l'arrire du boitier lectrique et cbl au
quips dun pr-filtre et dun post-filtre. Ils sont monts partir du capteur. Le transmetteur ne devrait tre install que lorsque le scheur
modle HL1200 et les modles plus petits. Ils sont expdis comme est prt etre mis en service.
pices dtaches partir du modle HL1500 et les modles plus gros. Pour installer le transmetteur de point de rose :
AVIS Dballer le transmetteur.
Vrifier que la rondelle est en place sous l'crou du transmetteur.
Tous les dessiccateurs doivent disposer de la filtration approprie. Au Visser le transmetteur dans le bloc 'capteur' comme indiqu.
minimum, un filtre de coalescence 0,3 microns vidange automatique Cbler le transmetteur. Contrler que la vis de fixation du cble du
et filtre finisseur particules doit tre utilis. Tout manque de fournir
transmetteur soit compltement engage dans le filetage du
une filtration correcte peut annuler la garantie du dessiccateur.
transmetteur.
Les pr-filtres de coalescence, situs avant le dessiccateur, protgent
les lits de dessiccation contre la contamination par lhuile, leau
dentranement, le tartre de tuyau, etc. allongeant ainsi la dure de vie
du matriel dessiccant. Positionnez les pr-filtres aussi prs que
possible du dessiccateur.
CBLE METTEUR
FIXATION DE VIS
CBLE METTEUR
EMETTEUR
VAISSELLE
DETECTION DE BLOC
9.6 BRANCHEMENT LECTRIQUE rose lev. Selon la dure du temps dinutilisation, il faudra entre une
(1) douze (12) heures pour annuler la condition dalarme, pour que
Effectuez tous les branchements lectriques du dessiccateur comme
lindicateur dhumidit bleu (IHB) reprenne sont tat bleu normal et pour
lindique le schma de cblage. Il faudra faire attention deffectuer les
que le point de rose chute.
branchements la bonne tension.
AVIS Ouvrez lentement la soupape de refoulement pour pressuriser
graduellement la tuyauterie en aval.
Le dessiccateur doit tre mis la terre avec un cble de mise la terre
pleine dimension raccord une mise la terre. AVIS
AVIS Lors de louverture de la soupape de refoulement, assurez-vous que la
Le dessiccateur doit tre protg par des fusibles respectant les pression de fluide est maintenue au niveau de la jauge de la tour de
normes NEC et correspondant la capacit du fusible indique sur la dessiccation. Pour viter les conditions de dpassement, ne laissez
plaque signaltique du dessiccateur ou aux spcifications de la fiche pas la pression chuter dans le dessiccateur.
technique dans le manuel.
AVIS
Dimensionnez les trous dfoncer de connexion sur site selon le raccord de Les dessiccateurs -100 F ncessitent que lair circule travers le
conduit exige par les normes NEC. dessiccateur pour rduire le point de rose des niveaux nominaux.
Tout manque de laisser lair circuler dans le dessiccateur (circulation
9.7 VRIFICATION DU NIVEAU DE MATRIEL DESSICCANT
vide) conduira des points de rose de sortie levs. Une fois que lair
Enlevez lorifice de remplissage du matriel dessiccant et le haut de la peut circuler dans le dessiccateur, le point de rose de pression
cuve de matriel dessiccant et vrifiez le niveau. Il doit correspondre au diminuera graduellement aux niveaux nominaux.
niveau indiqu dans le tableau de remplissage de matriel dessiccant,
donn la fin du manuel. Une charge initiale de matriel dessiccant est
introduite dans les dessiccateurs en usine. 9.9 SQUENCE DARRT
9.8 DMARRAGE
AVIS
Mettez lentement le dessiccateur sous pression. Lorsque le
dessiccateur atteint sa pression de fonctionnement, vrifiez quil ny a Avant de couper lalimentation lectrique ou lair comprim du
aucune fuite dans le systme. Testez leau savonneuse tous les dessiccateur, appuyez sur la touche OFF sur le contrleur par
joints et raccords. Pour maintenir les points de rose, toutes les fuites microprocesseur. Ceci initialise la squence darrt, qui ferme les
dtectes doivent tre rpares, tout spcialement celles du ct soupapes de purge, remet sous pression la tour hors ligne et ouvre les
sortie du dessiccateur. soupapes de dbit. NE COUPEZ PAS LALIMENTATION
Vrifiez que la soupape de rglage de purge est ouverte et que le LECTRIQUE OU LAIR COMPRIM DU DESSICCATEUR LORS
robinet darrt de sortie dair (si install) est ferm. DUNE SQUENCE DARRT.
Pour les dessiccateurs quips dun EMS (SEG), enlevez le capteur
de surveillance de point de rose du coffret lectrique et installez-le Maintenez une source dair comprim au dessiccateur et une
dans le bloc de dtection, situ ct du coffret et fixez le cble du alimentation lectrique au contrleur par microprocesseur.
capteur au capteur.
Mettez le dessiccateur sous tension partir du sectionneur (fourni par SHUTDOWN
le client). Laffichage cristaux liquides sur le contrleur par OFF
microprocesseur sallume. SEQUENCE
Dmarrez le dessiccateur en appuyant sur la touche ON du contrleur
Appuyez sur la touche OFF pour initialiser la SHUTDOWN
par microprocesseur.
SEQUENCE (SQUENCE DARRT).
Pendant les 30 premires secondes de la mise sous tension du
dessiccateur, les deux soupapes de purge restent fermes. Aprs 30
secondes, la soupape de purge de la tour gauche souvre entranant Permettez au dessiccateur dexcuter une SQUENCE DARRT
la dpressurisation de la tour gauche. complte(30secondes)
laide dun voltmtre, vrifiez que les connexions lectriques
correspondent la tension nominale indique sur la plaque
PRESS ON
signaltique du dessiccateur.
SELECT
DISPLAY
EMS: OFF 1 EMS SET POINT
-41_
Appuyez sur la touche SELECT DISPLAY jusqu ce que
lcran ENERGY MANAGEMENT SYSTEM (SYSTME DE Utilisez les chiffres sur le clavier pour entrer la temprature
GESTION DNERGIE) soit affich. de point de rose de pression voulue pour le point de
consigne EMS (SEG).
+
- EMS: ON EMS SET POINT
ENTER
-41
Appuyez sur la touche +/- jusqu ce que le point de
consigne voulu soit affich. Appuyez sur la touche SELECT Appuyez sur ENTER pour sauvegarder le point de consigne
DISPLAY pour sauvegarder la slection en cours. slectionn.
SELECT
EMS SET POINT Les dessiccateurs HL (sans chaleur) doivent tre configurs pour
redmarrer sous lun des deux modes de fonctionnement suivants.
DISPLAY -43 Comme dcrit dans la section 5, le dessiccateur peut tre configur
pour un fonctionnement manuel (dfini par dfaut en usine) ou pour un
Appuyez sur la touche SELECT DISPLAY jusqu ce que redmarrage automatique, permettant le redmarrage automatique du
lcran EMS SET POINT (POINT DE CONSIGNE SGE) soit dessiccateur la remise sous tension. Les illustrations suivantes
affich. montrent comment accder aux diffrents modes de dmarrage du
dessiccateur et comment les rgler :
10.5 DISPOSITIF DE RGLAGE DE DBIT DE PURGE 10.7 ALARME DE POINT DE ROSE LEV (INCLUS DANS
Le dispositif de rglage de dbit de purge permet lutilisateur de LOPTION EMS - SEG)
rduire la dure du cycle de purge afin que les conditions dadmission 10.7.1 DESCRIPTION ET ACTIVATION
au dessiccateur soient plus troitement suivies. Cette fonctionnalit
Le but de lalarme High Dew Point (point de rose lev) est
sadapte bien aux applications o lcoulement du dessiccateur est
de fournir loprateur une indication dalarme au cas o
constamment restreint, permettant ainsi que seule la quantit
lquipement ne pourrait plus fournir lair dalimentation son
ncessaire dair de purge soit utilise. La fonctionnalit de rglage de
point de rose de pression de conception. Le capteur de point
dbit de purge permet lutilisateur de choisir la dure relative du cycle
de rose EMS (SEG) communique la lecture de point de
de purge, de 30% 100%, en incrments de 10%.
rose de pression au contrleur par microprocesseur. Si le
point de rose de pression dpasse le point de consigne de
Les illustrations suivantes montrent comment accder la fonctionnalit
lalarme, le contrleur par microprocesseur affichera une
de rglage de dbit de purge et comment la rgler :
condition dalarme lcran du contrleur.
SELECT
PURGE ADJUST Les illustrations suivantes montrent comment activer la
fonctionnalit dalarme de point de rose lev :
DISPLAY % PRG SELECT 100
Appuyez sur la touche SELECT DISPLAY jusqu ce que SELECT
HIGH DEW PT
lcran PURGE FLOW ADJUSTER (DISPOSITIF DE
RGLAGE DE DBIT DE PURGE) soit affich.
DISPLAY OFF
Appuyez sur la touche SELECT DISPLAY jusqu ce que
+ PURGE ADJUST lcran HIGH DEW POINT (POINT DE ROSE LEV)
-
% PRG SELECT 70 soit affich.
+
COMP INTERLOCK Dans le cas contraire, passez ltape suivante.
- ON
Appuyez sur la touche +/- jusqu ce que le point de
consigne voulu soit affich. Appuyer sur SELECT DISPLAY
pour sauvegarder la slection en cours.
14 HL Series Desiccant Dryer Models 90-5000
http://www.ingersollrandproducts.com
10.0 TECHNICIAN MODE (MODE TECHNICIEN)
HI PDP SETPOINT
ENTER
-21
Appuyez sur ENTER pour sauvegarder le point de consigne
slectionn.
Vrifiez que le cyclage, la dpressurisation et la repressurisation du Remettez neuf les robinets diaphragme de permutation et de purge
dessiccateur fonctionnent correctement. (prventif).
Vrifiez que le drainage du pr-filtre fonctionne correctement et quil Remplacez les soupapes de refoulement (prventif).
ny a pas de dcharge de condensats au niveau des silencieux de
purge. Remplacez les cartouches plus frquemment au besoin selon 11.2 PR-FILTRES ET POST-FILTRES
la valeur de la pression diffrentielle donne par lindicateur. Pr-filtres Les cartouches du pr-filtre doivent tre changes aussi
Vrifiez que la pression dans la tour en purge est infrieure ou gale souvent que ncessaire afin dviter toute contamination du lit de
10 PSIG. Si elle est suprieure cette valeur, il est recommand de dessiccation du dessiccateur de rgnration.
changer le silencieux. (Section 11.4).
Vrifiez que les pressions diffrentielles du pr-filtre et du post-filtre Le pr-filtre et la vidange automatique doivent tre vrifis tous les
sont dans les limites de fonctionnement. Rglez au besoin. (Section jours. Pour prolonger la dure de vie de la cartouche du filtre, il est
11.2). Remplacez les cartouches plus frquemment au besoin selon la recommand quun sparateur dair / dhumidit mcanique soit plac
valeur de la pression diffrentielle donne par lindicateur. immdiatement avant le pr-filtre.
Vrifiez lindicateur dhumidit bleu. Vrifiez que lair peut tre purg
par lindicateur. Lindicateur devrait tre bleu lorsque lair est sec. AVIS
Si le systme de dessiccation est surcharg et/ou ne fonctionne pas
FONCTIONS DE MAINTENANCE TOUS LES SIX MOIS. correctement, provoquant ainsi une chute de pression importante, les
Vrifiez le point de rose la sortie. post-filtres pourront se boucher prmaturment. Ce problme peut
tre vit en vrifiant frquemment et en anticipant le remplacement
Vrifiez llment de filtre dair pilote et nettoyez ou remplacez au des cartouches.
besoin.
Remplacez les lments et/ou les cartouches de pr-filtre ou de post- Post-filtres Le but du post-filtre est dliminer la poussire rsiduelle
filtre. Remplacez les cartouches plus frquemment au besoin selon la
du matriel dessiccant. La frquence de changement de llment de
valeur de la pression diffrentielle donne par lindicateur.
filtre pourra varier en fonction de lapplication et de lutilisation de
lquipement. Il est recommand de changer llment de filtre au
FONCTIONS DE MAINTENANCE ANNUELLES: minimum tous les six mois.
Vrifiez le matriel dessiccant et remplacez-le au besoin.
MISE EN GARD
Vrifiez et nettoyez les soupapes de vidange sans perte de commande
dair pilote et vrifiez les soupapes et les robinets diaphragme. Pour viter toute blessure corporelle, dpressurisez le dessiccateur
Remettez neuf et/ou remplacez au besoin. avant dexcuter tout entretien.
Testez les interrupteurs et les voyants lumineux et les remplacez au
besoin.
Testez les composants lectriques et les remplacez au besoin.
TAPE 1 - TAPE 2 -
l'aide d'une cl Enlevez l'ancien
douilles de 2 lment du
po. dote d'une botier du filtre.
rallonge,
desserrez
dlicatement
l'lment.
TAPE 3 - TAPE 4 -
Installez le Serrez l'lment
nouvel lment la main jusqu'
en insrant ce que le joint
dlicatement torique de
l'lment dans l'lment entre
la plaque en contact avec
suprieure. la plaque
suprieure.
TAPE 5 - TAPE 6 -
l'aide d'une cl Rptez la
douilles de 2 po. procdure au
dote d'une besoin pour
rallonge, serrez remplacer tous
l'lment d'un les lments.
demi-tour. NE
PAS TROP
SERRER.
11.3 SOUPAPES DE VIDANGE SANS PERTE DE COMMANDE 11.8 PROCDURE DE CHANGEMENT DU MATRIEL DESSICCANT
DAIR PILOTE Lorsquil devient ncessaire de remplacer le matriel dessiccant dans
La dure de fonctionnement fiable des lectrovalves dair pilote sans les tours, ralisez la procdure suivante :
avoir effectuer de remplacement dpend du type de dessiccateur et
de son opration. Sur les dessiccateurs de point de rose -40F MISE EN GARDE
Ingersoll Rand, il est recommand de changer les lectrovalves tous les
60 mois. tant donn la diffrence dans les temps de cycle pour les Pour viter toute blessure, dpressurisez le dessiccateur avant
units -100F, il sera ncessaire de remplacer les lectrovalves sur ces dexcuter tout entretien.
dessiccateurs tous les 30 mois.
ATTENTION
11.4 PROCDURE DE CHANGEMENT DU SILENCIEUX Portez toujours un masque de protection respiratoire lors de la
procdure de vidange et de remplissage afin de minimiser linhalation
du matriel dessiccant, puisque cette procdure produit invitablement
MISE EN GARDE de la poussire.
Pour viter toute blessure corporelle, dpressurisez le dessiccateur
avant dexcuter tout entretien.
AVIS
Chaque dessiccateur est expdi avec une trousse dchantillonnage
Pour dpressuriser le dessiccateur, coupez lalimentation de contrle. de matriel dessiccant pour quil puisse tre envoy pour analyse.
Cette trousse peut tre utilise pour que le matriel dessiccant puisse
Remplacez le silencieux.
tre examin par un laboratoire. Veuillez suivre les instructions
Suivez la procdure de dmarrage dcrite la section 9.7. accompagnant la trousse.
Branchez nouveau lalimentation de contrle.
Les units standard sont quipes dorifices de remplissage et de
vidange sur chaque tour de dessiccation. Enlevez les bouchons sur les
11.5 ROBINETS DIAPHRAGME DE PERMUTATION ET DE
deux orifices.
PURGE (HL90 - HL2700)
Ces robinets ont deux orifices de contrle; un sur le haut et lautre Pour faciliter la circulation du matriel dessiccant de la tour, insrez
larrire. une petite tige dans lorifice de vidange, au besoin. Ceci peut savrer
ncessaire, car le matriel dessiccant est entass dans les tours, ce
Robinets normalement ouverts (N.O.) : Pour les robinets dadmission qui peut gner la circulation du matriel dessiccant dans les tours.
ou de repressurisation N.O., lair de contrle est aliment lorifice du
haut. Lorifice larrire permet lchappement de lair du ct bas du Des tamis de retenue, situs sur les raccords de tuyauterie
diaphragme. Si lair fuit continuellement lorsque le robinet est aliment dadmission et de refoulement de la tour, peuvent tre enlevs sur tous
en air de contrle, les joints internes ne sont pas tanches et ils les modles. Il est recommand que ces tamis soient enlevs et
doivent tre remplacs. nettoys lors du changement du matriel dessiccant. Lon peut
accder ces tamis en dbranchant les collecteurs suprieur et
Robinets normalement ferms (N.F.) : Pour les robinets de purge infrieur des tours de dessiccateur.
normalement ferms, lorifice du haut est bouch. Lair de contrle est
aliment lorifice du bas. Si lair est continuellement vacu de Aprs le nettoyage des tamis de retenue, remettez les tamis en place
lorifice du bas lorsque le solnode est mis hors tension, et fixez nouveau le bouchon dorifice de sortie.
lchappement dair se fera par le haut du solnode. Dans ce cas, les
joints internes ne sont pas tanches et ils doivent tre remplacs. Avec le bouchon dorifice de remplissage enlev, remplissez la tour de
dessiccateur avec la catgorie et le calibre appropris de matriel
11.6 ACTIONNEUR COMMANDE PAR PILOTE (HL3300 - HL5000) dessiccant. Le niveau de matriel dessiccant devrait se trouver en
Si l'actionneur ne tourne pas, dbranchez les lignes pilote pour vrifier dessous du tamis de retenue suprieur comme lindique le tableau de
si l'actionneur reoit de la pression pilote. remplissage de matriel dessiccant ci-dessous.
Si l'actionneur reoit de la pression : Une fois que les tours ont t remplies, replacez le bouchon dorifice
Vrifiez que la pression de commande est de 75 psig au minimum. de remplissage sur chaque tour.
Assurez-vous que la soupape d'aspiration n'est pas bouche.
Ltanchit de tous les raccords qui ont t touchs lors de la
procdure de changement de matriel dessiccant doit tre teste
11.7 SOUPAPES DE REFOULEMENT avant la remise en service du dessiccateur.
Ltanchit des soupapes de refoulement peut tre vrifie en
dpressurisant le dessiccateur et en appliquant lentement une pression
sur la sortie. Les soupapes devraient faire tanchit et empcher lair
de pressuriser les tours. Si une tour commence se pressuriser, la
soupape de refoulement sur ce ct a besoin dtre remplace.
N de modle A B
CRIBLE MOLCULAIRE
HL90 20po 30po
HL120 7po 20.38po N de modle A B
HL160 18po 29.75po HL1000 14.5po 31.5po
HL200 7po 21.50po HL1200 4po 23.75po
HL250 16po 28po HL1500 6po 23.25po
HL300 7po 21.25po HL1800 31.50po 45.75po
HL400 8po 22.25po HL2100 22po 38.5po
HL500 20po 34.75po HL2700 6po 26po
HL3300 16.25po 5.25po
HL600 10po 27.50po
HL4000 7.75po 29po
HL800 27po 41po
HL5000 9po 28po
Tolrance = +/- 0,50
TABLEAU DE REMPLISSAGE DE MATRIEL DESSICCANT
MODLE HL DESSICCATEU DESSICCATEU DESSICCATE
(SANS RS -40F RS -100F URS -100F
CHALEUR) LB.AA LB.AA LB.CM
HL90 100 75 25 DESCRIPTION NO. DE PICE
HL120 134 101 34
HL160 192 144 48 QT DALUMINE ACTIVE (1) SAC DE 50 LIVRES 38004834
HL200 236 177 59
HL250 290 218 73 QT DALUMINE ACTIVE (42) SACS DE 50 LIVRES 38004933
HL300 344 258 86
QT DALUMINE ACTIVE (1) SAC DE 2 000 LIVRES 38340659
HL400 470 353 118
HL500 638 479 160
QT DE CRIBLE MOLCULAIRE (1) FT DE 275 LIVRES 38449971
HL600 748 561 187
HL800 900 675 225
HL1000 1100 825 275
HL1200 1270 953 318
HL1500 1600 1200 400
HL1800 2000 1500 500
HL2100 2340 1755 585
HL2700 2928 2196 732
HL3300 3800 2850 950
HL4000 4226 3200 1026
HL5000 5138 3850 1288
AA = ALUMINE ACTIVE REMARQUE : La quantit est
MS = CRIBLE MOLCULAIRE par dessiccateur.
Reportez-vous, au besoin, aux descriptions de maintenance de la section 11 pour les procdures de dpannage.
Point de rose lev Taux de purge insuffisant Vrifiez les rglages du dbit de purge.
Dbit suprieur celui des conditions de rgime Vrifiez le dbit et recherchez la cause de la demande
accrue. Corrigez les conditions de dbit.
Matriel dessiccant contamin par de lhuile Posez un pr-filtre adquat. Remplacez le matriel
dessiccant.
Indicateur dhumidit bleu Point de rose lev Reportez-vous aux mesures correctives de Point de
(IHB - BMI) indique un niveau rose lev ci-dessus.
dhumidit lev
IHB humide Selon le degr de saturation du matriel dessiccant, il
faudra au moins une semaine dutilisation continuelle de
lIHB pour quil revienne son tat bleu (sec).
Chute de pression excessive au Dbit excessif Vrifiez le dbit et recherchez ce qui provoque une
niveau du dessiccateur demande accrue.
Soupape de vidange sans perte dfectueuse Vrifiez la soupape de vidange sans perte.
Pas dair pilote Vrifiez la conduite dair pilote. Vrifiez que le filtre de la
conduite dair est propre.
Joint du robinet diaphragme command par Vrifiez et remplacez les joints dtanchit, au besoin.
air pilote dfectueux
Impossible de mettre le Soupape de purge dfectueuse Vrifiez que le circuit de repressurisation envoie un signal
dessiccateur sous pression de commande.
Le dessiccateur se La soupape de purge ne se ferme pas ; le Vrifiez la soupape de purge et sa soupape de vidange
dpressurise trop rapidement. dessiccateur se repressurise via la soupape sans perte.
daspiration
Impossible de purger le La soupape de purge ne souvre pas La Vrifiez la soupape de purge et sa soupape de vidange
dessiccateur soupape de purge est coince en position sans perte. Rparez et remplacez, au besoin.
ferme
Vrifiez que le circuit de repressurisation envoie un signal
de commande.
Contre-pression excessive Le silencieux de purge ne laisse pas passer lair Le silencieux de purge est sale, remplacez-le.
dans la tour en rgnration
(suprieure 5 psig) Le silencieux de purge laisse passer trop dair Vrifiez la soupape daspiration et les soupapes de
Lair fuit au niveau de la soupape refoulement. Vrifiez que la soupape daspiration est
ferme la tour de purge (tour 0 psig).
Haute pression excessive talonnage incorrect Rinitialisez lorsque la tour droite est en ligne.
dans la tour droite la jauge
de purge
12
10
0
0 10 20 30 40 50 60 70
20
30
18
16 25
14
12 20
10 15
8
6 10
4
5
2
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
40 50
35 45
30 40
35
25
30
20 25
15 20
15
10
10
5 5
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
65
80
Dbit d'air de purge - PCNM
60
55 70
50
45 60
40 50
35
30 40
25 30
20
15 20
10
10
5
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Rglage de compteur de purge psig Rglage de compteur de purge psig
110
100
100
90
90
80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
180 220
200
160
180
Dbit d'air de purge - PCNM
140
160
120 140
100 120
80 100
80
60
60
40
40
20 20
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Rglage de compteur de purge psig
Rglage de compteur de purge psig
300
210 270
180 240
210
150
180
120 150
90 120
60 90
60
30
30
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Rglage de compteur de purge psig
Rglage de compteur de purge psig
300
400 600
Dbit d'air de purge - PCNM
350
500
300
400
250
200 300
150 200
100
100
50
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Rglage de compteur de purge psig
Rglage de compteur de purge psig
800 800
Dbit d'air de purge - PCNM
700 700
600 600
500 500
400
400
300
300
200
200
100
100
0
0 10 20 30 40 50 60 70 0
0 10 20 30 40 50 60 70
Rglage de compteur de purge psig
Rglage de compteur de purge psig
10.19
CL OF AIR OUTLET
(4) .56'' DIA. MTG. HOLES
CL OF AIR OUTLET
DUST PARTICULATE
AFTERFILTER
TOWER PRESSURE ELECTRICAL ENCLOSURE PURGE ADJUSTMENT VALVE
GAUGE NEMA 4
CONTROLLER & DISPLAY PANEL
(SEE DETAIL) PURGE FLOW GAUGE 1/4'' MPT AUTOMATIC DRAIN
CONNECTION
BLUE MOISTURE
INDICATOR RELIEF VALVE
HIGH EFFICIENCY
PILOT AIR FILTER
PILOT AIR SHUT-OFF
CL OF AIR INLET 1'' FPT AIR INLET
VALVE CONNECTION
http://www.ingersollrandproducts.com
1/4'' MPT AUTOMATIC DRAIN HIGH EFFICIENCY
CONNECTION 56.56 PREFILTER
40.50 11.00
10.19 17.38
32.50
19.81
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
5) DRYER TO BE LIFTED BY LIFTING SUPPORT ONLY.
DISPOSITION GNRALE
HL90-HL120
580000-E
23
24
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF
2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING
4) LEFT/RIGHT TOWER REGEN LEFT TOWER DRYING LIGHT
5) DEW POINT (OPTIONAL)
FACE OF AIR INLET & OUTLET 6) REGEN SEQUENCE STATUS
(OPTIONAL 3-VALVE BYPASS) 8) COMPRESSOR INTERLOCK (OPTIONAL) DRYER OFF / ALARM LIGHT
9) AUTO RESTART
2.00 TYP RIGHT TOWER REGEN LIGHT
PUSH BUTTONS RIGHT TOWER DRYING LIGHT
1) ON
2.00 (TYP) 2) OFF
3) RESET
32.56 4) TEST
5) SET
CONTROLLER & DISPLAY PANEL DETAIL
6) SELECT DISPLAY
43.75 7) ENTER
8) +/-
28.00
32.00
11.19
CL OF AIR OUTLET
34.50 FACE OF AIR OUTLET
(4) .56'' DIA. MTG. HOLES 1 1/2'' FPT AIR OUTLET
10.25 CONNECTION
20.00 (HL 200)
19.00 (HL 160)
1 1/2'' FPT AIR INLET
DESICCANT FILL PORT CONNECTION
CL OF AIR OUTLET
ELECTRICAL
TOWER PRESSURE GAUGE ENCLOSURE PURGE ADJUSTMENT VALVE
NEMA 4
CONTROLLER & DISPLAY PANEL DUST PARTICULATE
(SEE DETAIL) PURGE FLOW GAUGE
AFTERFILTER
1/4'' MPT AUTOMATIC DRAIN
BLUE MOISTURE CONNECTION
INDICATOR
RELIEF VALVE
PILOT AIR FILTER
CL OF AIR INLET
1/4'' MPT AUTOMATIC DRAIN
CONNECTION
59.50
66.12 HIGH EFFICIENCY
PREFILTER
http://www.ingersollrandproducts.com
PURGE MUFFLER CONNECTION
34.00
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSITION GNRALE
HL160-HL200
580001-D
FACE OF AIR INLET & OUTLET LCD DISPLAY POWER ON LIGHT
(OPTIONAL 3-VALVE BYPASS) 1) DRYER ON/OFF
2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
2.00 TYP 5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
2.00 TYP
RIGHT TOWER REGEN LIGHT
PUSH BUTTONS RIGHT TOWER DRYING LIGHT
1) ON
44.19 @ HL 250 2) OFF
50.38 @ HL 300 3) RESET
4) TEST
5) SET CONTROLLER & DISPLAY PANEL DETAIL
28.00 32.00 6) SELECT DISPLAY
7) ENTER
8) +/-
10.69
CL OF AIR OUTLET
DUST PARTICULATE
AFTERFILTER
TOWER PRESSURE ELECTRICAL
GAUGE ENCLOSURE PURGE ADJUSTMENT VALVE
NEMA 4
CONTROLLER & DISPLAY PANEL PURGE FLOW GAUGE
(SEE DETAIL)
1/4'' MPT AUTOMATIC DRAIN
CONNECTION
BLUE MOISTURE
INDICATOR RELIEF VALVE
PILOT AIR FILTER
PILOT AIR SHUT-OFF
VALVE
AIR INLET CONN.
http://www.ingersollrandproducts.com
1/4'' MPT AUTOMATIC DRAIN CL OF AIR INLET
CONNECTION 1 1/2'' FPT @ HL 250
2'' FPT @ HL 300
60.00
HIGH EFFICIENCY
PREFILTER
1/4'' MPT AUTOMATIC DRAIN
CONNECTION
14.0 DISPOSITIONS GNRALES
34.00
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSITION GNRALE
HL250-HL300
580002-D
25
26
38.50
LCD DISPLAY
1) DRYER ON/OFF POWER ON LIGHT
FACE OF AIR INLET & OUTLET 2) DRYER ALARM LEFT TOWER REGEN LIGHT
(OPTIONAL 3-VALVE BYPASS) 3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
50.94 2.00 TYP
32.00
11.19
CL OF AIR OUTLET
BLUE MOISTURE
INDICATOR RELIEF VALVE
1/4'' MPT AUTOMATIC
PILOT AIR FILTER DRAIN CONNECTION
L
1/4'' MPT AUTOMATIC DRAIN CL OF AIR INLET 2'' FPT AIR INLET
CONNECTION CONNECTION
60.25
67.81
http://www.ingersollrandproducts.com
HIGH EFFICIENCY
PREFILTER
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSITION GNRALE
HL400
580003-D
40.50 LCD DISPLAY
1) DRYER ON/OFF POWER ON LIGHT
2) DRYER ALARM LEFT TOWER REGEN LIGHT
FACE OF AIR INLET & OUTLET 3) LEFT/RIGHT TOWER DRYING
(OPTIONAL 3-VALVE BYPASS) 4) LEFT/RIGHT TOWER REGEN LEFT TOWER DRYING LIGHT
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
2.00 TYP
RIGHT TOWER REGEN LIGHT
54.50 @ HL500 PUSH BUTTONS RIGHT TOWER DRYING LIGHT
57.25 @ HL600 1) ON
2.00 (TYP) 2) OFF
(4) O .56 MOUNTING HOLES
3) RESET
4) TEST
5) SET CONTROLLER & DISPLAY PANEL DETAIL
6) SELECT DISPLAY
7) ENTER
8) +/-
29.00 33.00
12.19
CL OF AIR OUTLET
FACE OF AIR OUTLET
11.50
27.50 @ HL 500
30.25 @ HL 600 2'' FPT AIR OUTLET
CONNECTION
CL OF AIR OUTLET
HIGH EFFICIENCY
http://www.ingersollrandproducts.com
PREFILTER
12.19 20.81
17.00
27.50 @ HL 500
56.50 30.25 @ HL 600 40.50
FACE OF AIR INLET CL OF AIR INLET
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
GDISPOSITION GNRALE
HL500-HL600
580004-D
27
28
FACE OF AIR INLET & OUTLET
(OPTIONAL 3-VALVE BYPASS)
9.62 PURGE ADJUSTMENT VALVE
2.00 TYP
(4) .56''O MOUNTING HOLES 44.00 3.00 TYP FACE AIR OUTLET CL OF AIR OUTLET
CL AIR OUTLET
ELECTRICAL
ENCLOSURE
NEMA 4
http://www.ingersollrandproducts.com
DRAIN CONNECTION
PILOT AIR FILTER
69.25 PURGE
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSITION GNRALE
HL800-HL1200
580005-E
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF
2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
ELECTRICAL
ENCLOSURE CL OF AIR OUTLET
NEMA 4
RELIEF VALVE
TOWER PRESSURE
GAUGE
BLUE MOISTURE
INDICATOR
PURGE MUFFLER
PILOT AIR
SHUT-OFF 80.06 PILOT AIR FILTER
VALVE PURGE FLOW
GAUGE
http://www.ingersollrandproducts.com
56.88
CL OF AIR INLET
DRAIN PORT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSITION GNRALE
HL1500
580006-D
29
30
LCD DISPLAY
1) DRYER ON/OFF POWER ON LIGHT
2) DRYER ALARM
3) LEFT/RIGHT TOWER DRYING LEFT TOWER REGEN LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL) LEFT TOWER DRYING LIGHT
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
(4) .56''O MOUNTING HOLES 54.00 3.00 2.00 TYP 22.38 CL OF AIR OUTLET 4'' 150# R.F. FLANGE
TYP AIR OUTLET CONNECTION
OUTLET CHECK OUTLET CHECK
38.12 FACE OF OUTLET VALVE VALVE
CONTROLLER AND
2'' NPT PLUG DISPLAY PANEL
DESICCANT (SEE DETAIL)
FILL PORT
CL OF AIR OUTLET
ELECTRICAL
ENCLOSURE
NEMA 4
PURGE CHECK
VALVE
PURGE CHECK
VALVE
TOWER PRESSURE
GAUGE RELIEF
BLUE VALVE
MOISTURE
91.88 INDICATOR
PURGE FLOW
GAUGE PURGE
PURGE ADJUSTMENT
MUFFLER VALVE
67.25
http://www.ingersollrandproducts.com
PILOT AIR CL OF AIR INLET
FILTER
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSITION GNRALE
HL1800-HL2100
580029-D
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF LEFT TOWER REGEN LIGHT
2) DRYER ALARM LEFT TOWER DRYING LIGHT
3) LEFT/RIGHT TOWER DRYING
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
60.75
RIGHT TOWER REGEN LIGHT
PUSH BUTTONS RIGHT TOWER DRYING LIGHT
43.00 47.00 1) ON
2) OFF
3) RESET
4) TEST
5) SET CONTROLLER & DISPLAY PANEL DETAIL
6) SELECT DISPLAY
7) ENTER
8) +/-
2.00 (TYP)
(4) .56''O MOUNTING HOLES
3.00 (TYP)
54.00
38.25 FACE OF OUTLET 22.38 CL OF AIR OUTLET 4'' FLANGE AIR
OUTLET CONNECTION
2'' NPT PLUG
DESICCANT
FILL PORT
91.88
PURGE
ELECTRICAL ADJUSTMENT
ENCLOSURE VALVE
TOWER PRESSURE NEMA 4
GAUGE RELIEF VALVE
BLUE
MOISTURE
INDICATOR PURGE FLOW
GAUGE
PURGE
MUFFLER
PILOT AIR
http://www.ingersollrandproducts.com
FILTER
67.25
PILOT AIR
2'' NPT PLUG SHUT-OFF 26.12
DESICCANT VALVE
DRAIN PORT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSITION GNRALE
HL2700
580007-D
31
32
5.88
60.00
(4) .56''O MOUNTING HOLES 1.50 (TYP) PILOT AIR FILTER
63.00
CLOF OUTLET
66.00
6'' RAISED FLANGE 150#
41.38 FACE OF OUTLET AIR OUTLET CONNECTION
23.00
CHECK VALVE
DESICCANT
FILL PORT
CL OF AIR OUTLET
100.00
PURGE FLOW
BLUE MOISTURE GAUGE
INDICATOR CL OF AIR INLET
6'' FLUSH FLANGE 125#
72.25 AIR INLET CONNECTION
http://www.ingersollrandproducts.com
PURGE VALVE
FLOW VALVE
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
5) FILTER PACKAGES SHIPPED SEPARATELY.
FILTER PIPING SUPPORT, IF REQUIRED, TO BE
SUPPLIED BY CUSTOMER.
DISPOSITION GNRALE
HL3300-HL4000
580092-E
12.00
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF
CL OF MOUNTING HOLE 2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
7) COMPRESSOR INTERLOCK
8) AUTO RESTART DRYER OFF / ALARM LIGHT
32.50
6.00 (TYP)
CL OF MOUNTING HOLE
PILOT AIR FILTER
60.00
(4) O .62 MOUNTING HOLES 1.50 (TYP)
63.00
ELECTRICAL
CONTROLLER AND ENCLOSURE CL OF AIR OUTLET
DISPLAY PANEL NEMA 4
(SEE DETAIL)
TOWER PRESSURE
GAUGE PURGE ADJUSTMENT
VALVE
TOWER RELIEF
VALVE
http://www.ingersollrandproducts.com
64.00
FLOW VALVE
34.75
PURGE MUFFLER
DESICCANT DRAIN PORT
14.0 DISPOSITIONS GNRALES
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
5) FILTER PACKAGES SHIPPED SEPARATELY.
FILTER PIPING SUPPORT, IF REQUIRED, TO BE
SUPPLIED BY CUSTOMER.
DISPOSITION GNRALE
HL5000
580306-B
33
15.0 SCHMA DE CBLAGE
SCHMA DE CBLAGE
HL90-HL5000
TM-580078-C
SCHMA DE PROCD
HL90-HL2700
580022-E
SCHMA DE PROCD
HL3300-HL5000
580213-C
QT/ PICES DE
DESCRIPTION HL901H00AA HL1201H00AA HL1601H00AA HL2001H00AA HL2501H00AA
UNIT RECHANGE
1 2 3
MATRIEL DESSICCANT,
NOTE 1 NOTE 1 NOTE 1 NOTE 1 NOTE 1 NOTE 1
4-8 mm CATGORIE D
SOUPAPE, BILLE, AIR DE COMMANDE, 1/4po 38054086 38054086 38054086 38054086 38054086 1
Pices de rechange Les quantits sous cet en-tte refltent le nombre de pices de rechange quil faut garder sous la main pour la rparation ou lentretien.
La quantit convenant le mieux votre application dpendra du degr de ncessit de votre opration en cas dinterruption de service.
Classe Quantit Suggre pour
1 Minimum Service domestique lorsque des interruptions de service sont acceptables.
2 Moyen Service domestique lorsque certaines interruptions de service sont acceptables.
3 Maximum Service dexportation ou service domestique lorsque des interruptions de service sont inacceptables.
Pices de rechange Les quantits sous cet en-tte refltent le nombre de pices de rechange quil faut garder sous la main pour la rparation ou lentretien.
La quantit convenant le mieux votre application dpendra du degr de ncessit de votre opration en cas dinterruption de service.
Classe Quantit Suggre pour
1 Minimum Service domestique lorsque des interruptions de service sont acceptables.
2 Moyen Service domestique lorsque certaines interruptions de service sont acceptables.
3 Maximum Service dexportation ou service domestique lorsque des interruptions de service sont inacceptables.
38 HL Series Desiccant Dryer Models 90-5000
http://www.ingersollrandproducts.com
17.0 PICES DE RECHANGE
PICES DE
DESCRIPTION HL10001H00AA HL12001H00AA HL15001H00AA HL18001H00AA HL21001H00AA
QT/ RECHANGE
UNIT
1 2 3
SOUPAPE DE SCURIT / DE
38054060 38054060 38054060 - - 2
DTENTE 1/2po
SOUPAPE DE SCURIT / DE
- - - 38446506 38446506 2
DTENTE 3/4po
Pices de rechange Les quantits sous cet en-tte refltent le nombre de pices de rechange quil faut garder sous la main pour la rparation ou lentretien.
La quantit convenant le mieux votre application dpendra du degr de ncessit de votre opration en cas dinterruption de service.
Classe Quantit Suggre pour
1 Minimum Service domestique lorsque des interruptions de service sont acceptables.
2 Moyen Service domestique lorsque certaines interruptions de service sont acceptables.
3 Maximum Service dexportation ou service domestique lorsque des interruptions de service sont inacceptables.
PICES DE
DESCRIPTION HL27001H00AA HL33001H00AA HL40001H00AA HL50001H00AA QT/ RECHANGE
UNIT
1 2 3
Pices de rechange Les quantits sous cet en-tte refltent le nombre de pices de rechange quil faut garder sous la main pour la rparation ou lentretien.
La quantit convenant le mieux votre application dpendra du degr de ncessit de votre opration en cas dinterruption de service.
Classe Quantit Suggre pour
1 Minimum Service domestique lorsque des interruptions de service sont acceptables.
2 Moyen Service domestique lorsque certaines interruptions de service sont acceptables.
3 Maximum Service dexportation ou service domestique lorsque des interruptions de service sont inacceptables.
40 HL Series Desiccant Dryer Models 90-5000
http://www.ingersollrandproducts.com
17.0 PICES DE RECHANGE
DESCRIPTION DE VALVE VALVE W/ ACT SEULE VANNE VALVE REPAIR KIT ACTIONNEUR ACTIONNEUR
KIT
ROBINET A PAPILLON 3 po W / 38053393 23126865 23126923 23126980 23127053
ACTIONNEUR
ROBINET A PAPILLON 3 po W / 38053419 23126881 23126964 23127004 23127038
ACTIONNEUR
MODLE Dbit Dbit Dbit Largeur Profondeur, Profondeur, Hauteur, Raccord Poids Matriel
daspiratio daspiration de pouce (cm) pouce, sans pouce, avec pouce (cm) dadmissio lexpdition, dessiccant
n, point de , point de purge contournemen contournement n et de livres, (kg) Poids par
rose -40 rose -100 PCNM t (cm) (cm) sortie dair dessiccateur,
PCNM PCNM livres (kg)
HL90 90 72 14 40.5 (102.9) 30 (76.2) 37.5 (95.3) 63 12 (160.3) 1 475 (213) 100 (45)
HL120 120 96 19 40.5 (102.9) 30 (76.2) 37.5 (95.3) 63 12 (160.3) 1 563 (255) 134 (61)
HL160 160 128 26 44.5 (113) 32 (81.3) 43.75 (111.1) 66.12 (167.9) 1 1/2 707 (321) 192 (87)
HL200 200 160 30 44.5 (113) 32 (81.3) 43.75 (111.1) 66.12 (167.9) 1 1/2 731 (332) 236 (107)
HL250 250 200 40 48.5 (123.2) 32 (81.3) 44.19 (112.2) 66.81 (169.7) 1 1/2 869 (394) 290 (132)
HL300 300 240 48 48.5 (123.2) 32 (81.3) 50.38 (128.0) 66.81 (169.7) 2 924 (419) 344 (156)
HL400 400 320 65 52.5 (133.4) 36.19 (91.9) 50.94 (129.4) 67.81 (172.2) 2 1115 (506) 470 (213)
HL500 500 400 81 56.5 (143.5) 39.69 (100.8) 54.5 (138.4) 82.5 (209.6) 2 1564 (709) 638 (289)
HL600 600 480 93 56.5 (143.5) 42.4 (107.8) 57.25 (145.4) 82.5 (209.6) 2 1664 (755) 748 (339)
HL800 800 640 130 64 (162.6) 51.25 (130.2) 64.38 (163.5) 87.62 (222.6) 3 2017 (915) 900 (408)
HL1000 1000 800 162 64 (162.6) 51.25 (130.2) 64.38 (163.5) 87.62 (222.6) 3 2237 (1015) 1100 (499)
HL1200 1200 960 195 64 (162.6) 51.25 (130.2) 64.38 (163.5) 87.62 (222.6) 3 2424 (1100) 1270 (576)
HL1500 1500 1200 243 78 (198.1) 54.76 (139.1) N/A 80 (203.2) 4 2974 (1349) 1600 (726)
HL1800 1800 1440 292 84 (213.4) 60.62 (154.0) N/A 91.88 (233.4) 4 3905 (1771) 2000 (907)
HL2100 2100 1680 340 84 (213.4) 60.62 (154.0) N/A 91.88 (233.4) 4 4279 (1941) 2340 (1062)
HL2700 2700 2160 438 84 (213.4) 60.76 (154.3) N/A 91.88 (233.4) 4 4926 (2234) 2928 (1328)
HL3300 3300 2640 535 96 (244) 66 (167.6) N/A 100 (254) 6 2950 (1338) 3800 (1723) *
HL4000 4000 3200 649 96 (244) 66 (167.6) N/A 100 (254) 6 3000 (1361) 4226 (1917) *
HL5000 5000 4000 811 102 (259) 72 (183) N/A 92 (233.7) 6 3950 (1792) 5138 (2330) *
Remarque : Tous les dessiccateurs indiqus ci-dessus ont une temprature dadmission max. nominale de 150 psig 120 F.
La capacit et le dbit de purge sont bass sur les conditions dadmission standard (100 psig et 100F) qui peuvent
varier des conditions dadmission diffrentes.
AVIS
Les informations de spcification donnes ci-dessus taient correctes au moment de la
publication de ce manuel. Reportez-vous ltiquette de srie de lquipement pour les
spcifications actuelles des units.
C.C.N. : 80442833 pt
DATA : ABRIL 2010
REV. :D
NDICE
NDICE PGINA NDICE PGINA
Os secadores de ar comprimido a frio da Ingersoll Rand foram chamado de dessoro (regenerao). Depois de uma rpida
projetados para adsorver umidade de ar comprimido. Os secadores despressurizao inicial, uma parte do ar seco da torre on-line passa
so construdos com duas torres, cada uma contendo pastilhas pelo leito de dessecante e leva a umidade para fora atravs do
dessecantes, que se alternam entre modos on-line (secagem) e off-line silenciador do secador.
(regenerao), resultando em um fluxo contnuo de ar seco na sada do
secador. O processo alternado de adsoro e dessoro contnuas controlado
usando-se um temporizador, que alterna as torres em uma seqncia
Durante a operao normal, ar mido passa pela torre on-line e o vapor de tempo especfica. Pontos de orvalho de ar comprimido muito seco
dgua do ar adsorvido (coletado) nos elementos dessecantes. so obtidos atravs da comutao e operao contnuas deste
Enquanto o ar est sendo adsorvido na torre on-line, a umidade do secador. A Ingersoll Rand oferece secadores que proporcionam ar na
dessecante da torre off-line est sendo removida por um processo sada com ponto de orvalho de -40F ou -100F.
3.0 GARANTIA
A empresa garante que o seguinte equipamento fabricado e entregue de desempenho esteja limitada a testes especificados, a obrigao da
sob as condies aqui estabelecidas est livre de defeitos decorrentes empresa consistir nas correes, das maneiras e dentro do perodo
de materiais e fabricao por um perodo de doze meses a partir da de tempo supracitados.
data de entrada do equipamento em operao ou dezoito meses a partir
da data de remessa da fbrica, o que ocorrer antes. O comprador est A EMPRESA NO D QUALQUER OUTRA GARANTIA OU FAZ
obrigado a prontamente informar empresa, por escrito, qualquer falha QUALQUER REPRESENTAO DE QUALQUER TIPO, EXPRESSA
coberta por esta garantia dentro do perodo supracitado. Mediante o OU IMPLCITA, EXCETO AQUELAS DO TTULO, NEM ASSUME
recebimento de tal informao, a companhia poder optar, a seu QUALQUER RESPONSABILIDADE IMPLCITA DE SERVENTIA AO
exclusivo critrio, por corrigir este problema atravs de reparos USO DESTINADO OU ADEQUAO A UM PROPSITO ESPECFICO.
adequados ao equipamento ou fornecer peas de reposio, F.O.B. no
ponto de embarque, desde que o comprador tenha armazenado, A correo pela empresa de defeitos, sejam eles patentes ou latentes,
instalado, mantido e operado o equipamento de acordo com as prticas das maneiras e dentro do perodo de tempo supracitado, constituir-se-
industriais apropriadas e tenha seguido as recomendaes especficas em cumprimento de todas as responsabilidades da empresa por tais
da empresa. Acessrios ou equipamentos fornecidos pela empresa, defeitos, sejam as mesmas baseadas em contrato, negligncia da
mas fabricados por terceiros, sero cobertos por qualquer garantia que garantia, indenizao, responsabilidade estrita ou outra, com respeito
os respectivos fabricantes tenham cedido empresa e que possa ser ou decorrente do referido equipamento.
passada ao comprador. A empresa no se responsabiliza por quaisquer
reparos, substituies ou ajustes feitos ao equipamento, bem como por O comprador no deve operar qualquer equipamento que seja
quaisquer custos de mo-de-obra incorridos pelo comprador ou considerado defeituoso, sem antes notificar sua inteno de faz-lo,
terceiros, realizados e/ou incorridos sem aprovao prvia por escrito por escrito, empresa. Qualquer uso do equipamento defeituoso dar-
da empresa. se- por exclusiva responsabilidade, conta e risco do comprador.
Os efeitos decorrentes da corroso, eroso e uso e desgaste normal Observe que esta a garantia padro da Ingersoll Rand. Qualquer
so explicitamente excludos. As garantias de desempenho esto garantia em vigncia no momento da compra do equipamento, ou
limitadas quelas declaradas especificamente dentro da proposta da negociada como parte da ordem de compra, pode ter precedncia
empresa. A no ser que a responsabilidade por atender a tais garantias sobre esta garantia.
* As vazes nominais indicadas so para uma temperatura de entrada de 100F, temperatura ambiente de 100F e presso do ar comprimido de
100 PSIG.
AVISO
A nomenclatura mostrada acima representa opes da tabela de preos padro. Outras
opes esto disponveis. Para obter detalhes, consulte o suplemento de nomenclatura
especfico de seu secador.
ALERTA
Sob nenhuma circunstncia qualquer pessoa deve tentar erguer
objetos pesados sem o equipamento de suspenso apropriado (por
exemplo, guindaste, grua, ganchos e cabos ou empilhadeira).
PRESS ON
BOTES
+/- i
Permite que o usurio modifique valores de pontos de controle. Os Acesso de nvel restrito, exclusivo para uso de fbrica.
valores dos pontos de controle so ciclados ao longo de um intervalo
fixo. Tambm permite inserir nmeros negativos, no modo fbrica.
ou boto em branco
Permite que o usurio volte ao nvel de menu anterior.
O painel de status oferece uma indicao clara do status do secador, 7.8.2 PARMETROS MOSTRADOS PELO CONTROLADOR
atravs de indicadores LED luminosos. A ilustrao a seguir resume MICROPROCESSADOR
os recursos do painel: O controlador microprocessador pode mostrar diversos
parmetros do sistema. A seguir resumimos os parmetros os parmetros disponveis. Caso a condio de alarme
que podem ser acessados pressionando-se o boto SELECT persistir, depois de aproximadamente 30 segundos a tela de
DISPLAY do controlador microprocessador (observe que alarme ser exibida novamente.
alguns mostradores so opcionais, podendo no aparecer
em todos os modelos):
Alarme de falha de comutao (OPTIONAL) - (FAIL TO SHIFT)
Sensores de presso so includos para detectar a presso
Status da torre {LT DRY / RT REGEN ou LT REGEN / RT
dentro de cada torre. Em 0 PSIG os contatos esto
DRY}: Oferece confirmao visual do status de secagem e
normalmente fechados, o que envia um sinal para o
regenerao da torre.
controlador. Quando a torre pressurizada os contatos se
Etapa do temporizador {p. ex., STEP 4 TIME 120}: Tela abrem, interrompendo o sinal enviado para o controlador.
informativa que mostra a etapa atual do programa e o Durante o ciclo, o controlador microprocessador interroga os
tempo restante para a etapa exibida. sensores de presso, para determinar sua posio atual. O
Temperatura do ponto de orvalho (OPCIONAL) - {DEW controlador microprocessador compara, ento, a posio
POINT TEMP: XX}: Quando o secador equipado com o destes em relao a uma tabela de consulta dentro do
recurso de EMS (Energy Management System, sistema de programa. Se a posio de qualquer um dos contatos for
gerenciamento de energia), mostra informaes precisas diferente da posio esperada, o secador inicia o alarme de
do ponto de orvalho pressurizado na sada do secador. falha de comutao.
Status da purga (OPCIONAL) - {PURGE / NO PURGE}:
Indica se a unidade est atualmente consumindo ar de Alarme de ponto de orvalho alto (OPCIONAL) - (HIGH DEW
purga. Exige o EMS. POINT) Quando o secador a frio equipado com o recurso
Alarmes {ALARM LIST - PRESS ENTER}: Pressionar de EMS opcional, fornecido um sensor que detecta o
<ENTER> nesta mensagem permite consultar o status de ponto de orvalho pressurizado da sada do ar e exibe o
alarme atual e o histrico de alarmes. valor no controlador microprocessador. Para secadores
Tempos de operao e descarga - {OPERATING TIMES equipados com o recurso de EMS opcional, o sensor
PRESS ENTER}: Pressionar <ENTER> nesta mensagem usado para detectar uma condio de ponto de orvalho alto,
d acesso as horas de operao em funcionamento e em exibindo o alarme como High Dew Point.
descarga.
Modo de operao {OPERATING MODE: HEATLESS}: Lista de alarmes
Indica o modo de operao do secador. O controlador microprocessador armazena as 20 condies de
alarme mais recentes. Esses alarmes so armazenados com
7.8.3 ALARMES E SUAS FUNES informaes de tipo do alarme e data e hora da ocorrncia do
alarme. A lista pode facilitar muito a identificao e soluo de
Existem diversas condies de alarme que so detectadas problemas do secador e fornecer uma indicao de como o
pelo controlador microprocessador e usadas para alertar o secador operou durante funcionamento desassistido. A seguir
usurio de condies fora dos limites de tolerncia. Uma descrevemos o mtodo para acessar e consultar alarmes
vez que um alarme seja detectado, uma descrio do armazenados no controlador microprocessador:
alarme ser exibida na tela e o contato de alarme remoto
ser fechado. Durante uma condio de alarme, o boto
SELECT DISPLAY pode ser pressionado para se percorrer
Condio de alarme
O secador no deve jamais ser instalado onde a temperatura ambiente 9.3 TUBULAO
ou do ar exceder 120F, ou cair abaixo de 50F. Coloque o secador em
um local onde este no seja submetido a extremos de frio e calor Ligue as linhas de ar comprimido s conexes de entrada e sada.
causados pelo ambiente ou outras condies. Evite colocar o secador Coloque os pr-filtros o mais perto possvel do secador. Assegure-se de
em ambientes externos, ou onde este fique exposto aos elementos. que o posicionamento permita fcil manuteno. Consulte o desenho
de disposio geral.
AVISO
Observe que a entrada de ar mido fica localizada na tubulao inferior
A Ingersoll Rand recomenda que os silenciadores sejam limpos aps o
funcionamento inicial, para remover qualquer poeira de dessecante do secador, ao passo que a sada de ar seco est na tubulao
produzida durante o transporte. Aps fazer o secador funcionar pelo perodo superior. Em situaes em que o suprimento de ar exigido 24 horas
inicial de 30 minutos, desenergize/despressurize o secador e remova os por dia (no desejvel interromper o fluxo de ar), recomenda-se um
silenciadores. Desmonte e limpe o elemento removvel dentro do ncleo do sistema de desvio (bypass) de 3 vlvulas para desviar o fluxo do
silenciador. Reinstale os equipamentos antes de operar o secador. secador. Use o menor nmero possvel de cotovelos, para minimizar a
queda de presso.
Dessecador de ar comprimido srie HL, modelos 90-5000 9
http://www.ingersollrandproducts.com
9.0 INSTALAO E FUNCIONAMENTO INICIAL
Uma vez que toda a tubulao esteja conectada, todas as juntas, 9.5 INSTALAO DO TRANSMISSOR DE PONTO DE ORVALHO
inclusive aquelas do secador, devem ser testadas pelo mtodo da bolha (OPCIONAL)
com a linha pressurizada, para garantir que nenhuma junta tenha sido Em secadores equipados com EMS, o transmissor de ponto de orvalho
danificada durante o transporte ou instalao no local. enviado num contentor separado dentro da caixa elctrica para
proteger o transmissor durante a viagem. Antes de utilizar a opo
9.4 FILTRAGEM
EMS, o transmissor deve ser instalado no bloco sensor localizado no
importante que um pr-filtro e um ps-filtro sejam includos em sua lado ou atrs da caixa elctrica e o cabo do transmissor deve ser preso
instalao de secador. Todos os secadores so fornecidos, como ao sensor. Por favor, note que o transmissor deve ser instalado apenas
padro, com um pr-filtro e um ps-filtro. Estes j vm montados no quando o secador estiver pronto para ser comissionado.
HL1200 e em equipamentos menores, mas so fornecidos soltos no
HL1500 e equipamentos maiores. Para instalar o Transmissor de Ponto de Orvalho:
AVISO Retirar o Transmissor do pacote original.
Verifique que a anilha est colocada sob o hex. do Transmissor.
Todos os secadores tm de ter filtragem apropriada. Deve ser usado Enrosqque o Transmissor no Bloco Sensor como se mostra.
no mnimo um filtro coalescente de 0,3 mcron e com drenagem
Prenda o Cabo do Transmissor ao Transmissor. Assegure-se de que
automtica e particulado aps o filtro. No fornecer filtragem
encaixa completamente o Parafuso de Fixao do Cabo do Transmissor
adequada para o secador anular a garantia.
na rosca respectiva do Transmissor.
Pr-filtros coalescentes localizados antes do secador protegem os
elementos dessecantes contra contaminao por leo, gua arrastada, 9.6 CONEXES ELTRICAS
fragmentos de incrustrao da tubulao, etc., estendendo assim a vida Faa todas as conexes eltricas do secador conforme mostrado no
til do dessecante. Coloque os pr-filtros o mais perto possvel do secador. diagrama de fiao. Deve-se tomar cuidado para se conectar as
tenses apropriadas.
Recomenda-se que um separador mecnico seja instalado imediatamente
antes do pr-filtro, para remover o grosso de lquido e gua arrastada. AVISO
O secador precisa ser aterrado com um fio-terra inteiro conectado terra.
Ps-filtros de particulado, localizados aps o secador, ajudam a eliminar
a possibilidade de pulverizao do dessecante e seu transporte para o AVISO
sistema de ar. O secador deve ser protegido por fusveis de acordo com o NEC,
usando-se fusveis com a capacidade listada na placa de identificao
com o nmero de srie do secador, ou conforme a folha de
especificaes existente no manual tcnico.
TRANSMISSOR CABLE
PARAFUSO DE FIXAO
TRANSMISSOR CABLE
TRANSMISSOR
WASHER
SENSING BLOCK
Inicie o funcionamento do secador, pressionando o boto ON no Pressione o boto OFF para iniciar a seqncia de
controlador microprocessador. desligamento.
AVISO
Quando abrir a vlvula de sada, assegure-se de que o manmetro da
torre de secagem mantenha a presso da linha. Permitir que a presso
caia no secador resulta em uma condio de transbordamento.
ALERTA
+
PDP ADJUSTER
O MODO TCNICO deve ser acessado somente por pessoal de
assistncia tcnica qualificado. Alterar os pontos de controle no modo - DEW POINT: -4
tcnico tem um efeito significativo na operao do secador. Pontos de
controle incorretos podem danificar o secador e potencialmente Pressione o boto +/- at que o ponto de orvalho desejado
causar ferimentos graves. seja exibido. Pressionar SELECT DISPLAY salva a seleo
atual.
Para entrar no MODO TCNICO, faa o seguinte:
10.3 SISTEMA DE GERENCIAMENTO DE ENERGIA (OPCIONAL)
10.3.1 DESCRIO E ATIVAO
BEGIN
O recurso opcional EMS (Energy Management System,
2 3 TECHNICIAN MODE sistema de gerenciamento de energia) foi projetado para
minimizar a perda de ar de purga durante condies de baixo
fluxo ou baixa carga de gua. Um sensor de ponto de orvalho
Pressionar os botes 2 e 3 simultaneamente faz o sistema digital detecta o ponto de orvalho pressurizado real da sada
entrar no MODO TCNICO. de ar do processo. O sensor comunica a leitura do ponto de
orvalho pressurizado para o controlador microprocessador.
SELECT
EMS: OFF 1 EMS SET POINT
DISPLAY
-41_
Pressione o boto SELECT DISPLAY at que seja exibida a Use os nmeros do teclado para fornecer a temperatura de
tela ENERGY MANAGEMENT SYSTEM. ponto de orvalho pressurizado desejada para o ponto de
controle do EMS.
+
- EMS: ON EMS SET POINT
ENTER
-41
Pressione o boto +/- at que o ponto de controle desejado
seja exibido. Pressionar SELECT DISPLAY salva a seleo Pressionar ENTER salva o ponto de controle selecionado.
atual.
SELECT
EMS SET POINT Os secadores HL podem ser configurados para reiniciar em um de
dois modos de operao. Conforme descrito na seo 5, o secador
DISPLAY -43 pode ser configurado para operao manual (padro de fbrica) ou
reincio automtico, que permite que o secador seja reiniciado
Pressione o boto SELECT DISPLAY at que seja exibida a automaticamente uma vez que a energia seja restaurada ao secador.
tela EMS SET POINT. Na seqncia ilustramos o mtodo de acessar e ajustar os diversos
modos de incio do secador:
10.5 AJUSTE DO FLUXO DE PURGA 10.7 ALARME DE PONTO DE ORVALHO ALTO (INCLUDO COM A
O ajuste do fluxo de purga permite que o usurio reduza a durao do OPO EMS)
ciclo de purga, de forma a se adequar melhor s condies da entrada 10.7.1 DESCRIO E ATIVAO
do secador. Este recurso adequado para aplicaes em que o O propsito do alarme de ponto de orvalho alto fornecer ao
secador est constantemente abaixo do fluxo, permitindo que apenas a operador uma indicao de alarme se o equipamento deixar
quantidade necessria de ar de purga seja usada. O recurso de ajuste de fornecer ar com o ponto de orvalho pressurizado
do fluxo de purga permite que o usurio selecione a durao relativa do designado. O sensor de ponto de orvalho do EMS comunica
ciclo de purga de 30% a 100%, em incrementos de 10%. a leitura do ponto de orvalho pressurizado para o controlador
microprocessador. Caso o ponto de orvalho pressurizado
Na seqncia ilustramos o mtodo de acessar e ajustar o recurso de fique acima do ponto de controle configurado, o controlador
ajuste do fluxo de purga: microprocessador exibir a condio de alarme em sua tela.
SELECT
COMP INTERLOCK
DISPLAY OFF + HI PDP SETPOINT
-
-___
Pressione o boto SELECT DISPLAY at que seja exibida a
tela COMPRESSOR INTERLOCK. Para fornecer um nmero negativo, pressione o boto +/-.
Do contrrio, v para o passo seguinte.
+
COMP INTERLOCK
- ON
Pressione o boto +/- at que o ponto de controle desejado
seja exibido. Pressionar SELECT DISPLAY salva a seleo
atual.
14 Dessecador de ar comprimido srie HL, modelos 90-5000
http://www.ingersollrandproducts.com
10.0 MODO TCNICO
HI PDP SETPOINT
ENTER
-21
Pressionar ENTER salva o ponto de controle selecionado.
Verifique se as leituras do manmetro da torre esto dentro da Substitua os kits de vedao e os diafragmas das vlvulas de purga e
tolerncia de operao. das vlvulas de diafragma de comutao.
PASSO 1 - PASSO 2 -
Usando uma Remova o
chave soquete elemento velho
de 2 pol. com da caixa do
extenso, solte filtro.
cuidadosamente
o elemento.
PASSO 3 - PASSO 4 -
Instale o Aperte mo o
elemento novo, elemento no
inserindo lugar, at que o
cuidadosamente anel de vedao
o elemento na do elemento
placa superior. entre em contato
com a placa
superior.
PASSO 5 - PASSO 6 -
Usando uma Repita o
chave soquete procedimento
de 2 pol. com conforme a
extenso, aperte necessidade
o elemento, para substituir
dando meia todos os
volta. NO elementos.
APERTE
EXCESSIVA-
MENTE.
11.3 VLVULAS DE DRENAGEM SEM PERDA DO CONTROLE DE 11.7 VLVULAS DE RETENO DE SADA
AR PILOTO As vlvulas de reteno de sada podem ser verificadas
O tempo em que as vlvulas de ar piloto podem operar sem despressurizando-se o secador e aplicando-se lentamente presso
substituio depende do tipo do secador e de sua operao. Nos sada. As vlvulas devem fechar e impedir que o ar pressurize as torres.
secadores Ingersoll Rand com ponto de orvalho de -40F, recomenda- Se uma torre comear a pressurizar, a vlvula de reteno da mesma
se a substituio das vlvulas a cada 60 meses. Dada a diferena dos precisa ser substituda.
tempos de ciclo das unidades de -100F, esses secadores devem ter
suas vlvulas-piloto substitudas a cada 30 meses. 11.8 PROCEDIMENTO DE TROCA DO DESSECANTE
11.4 PROCEDIMENTO DE TROCA DO SILENCIADOR Quando for necessrio substituir o dessecante das torres, observe o
procedimento a seguir:
ALERTA ALERTA
Para evitar ferimentos, despressurize o secador antes de realizar Para evitar ferimentos, despressurize o secador antes de realizar
qualquer manuteno ou reparo. qualquer manuteno ou reparo.
PENEIRA MOLECULAR
N. do modelo A B
HL90 20" 30" N. do modelo. A B
HL120 7" 20.38" HL1000 14.5" 31.5"
HL160 18" 29.75" HL1200 4" 23.75"
HL200 7" 21.50" HL1500 6" 23.25"
HL250 16" 28" HL1800 31.50" 45.75"
HL300 7" 21.25" HL2100 22" 38.5"
HL400 8" 22.25" HL2700 6" 26"
HL500 20" 34.75" HL3300 16.25" 5.25"
HL4000 7.75" 29"
HL600 10" 27.50"
HL5000 9" 28"
HL800 27" 41"
Tolerncia = +/- 0,50
TABELA DE ENCHIMENTO DE DESSECANTE
Consulte as descries de manuteno da seo 11, conforme a necessidade, para procedimentos de identificao e soluo de problemas.
Ponto de orvalho elevado Taxa de purga insuficiente. Verifique as configuraes da vlvula de purga.
Presso de ar na entrada abaixo dos valores Verifique a fonte de presso e o sistema em relao a
de projeto. vazamentos.
Vazo maior do que os valores de projeto. Verifique a vazo e a causa da maior demanda.
Corrija a condio de vazo.
O indicador de umidade azul Ponto de orvalho elevado. Consulte as aes corretivas para Ponto de orvalho
(BMI, Blue Moisture Indicator) elevado acima.
indica alto nvel de umidade
BMI molhado. Dependendo do grau de saturao do dessecante, o
BMI pode levar uma semana ou mais de uso contnuo
para voltar a seu estado azul (seco).
Queda de presso excessiva Vazo excessiva. Verifique a vazo e a causa da maior demanda de ar.
no secador
Presso na entrada abaixo dos valores de projeto. Verifique a fonte de presso.
O secador no pressuriza Vlvula de purga com defeito. Verifique se o circuito de pressurizao est enviando o
sinal de controle.
O secador despressuriza muito A vlvula de purga no fecha; o secador Verifique a vlvula de purga e sua vlvula de drenagem
rapidamente repressuriza atravs da vlvula de entrada. sem perda.
O secador no descarrega A vlvula de purga no abre. A vlvula de Verifique a vlvula de purga e sua vlvula de drenagem
purga est presa na posio fechada. sem perda. Repare e substitua se necessrio.
Contrapresso excessiva na O silenciador da purga no deixa passar ar. O silenciador da purga est sujo. Substitua.
torre em regenerao (acima
de 5 PSIG) O silenciador da purga deixa passar ar Verifique a vlvula de entrada e as vlvulas de reteno
demais. Est vazando ar atravs da vlvula. de sada. Verifique se a vlvula de entrada est fechada
na torre em descarga (torre de 0 psig).
Presso excessiva no Calibrao inadequada. Zere quando a torre da direita estiver on-line.
manmetro de purga da torre
da direita
14
10
0
0 10 20 30 40 50 60 70
30
18
16 25
14
12 20
10 15
8
6 10
4
5
2
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
40 50
35 45
30 40
35
25
30
20 25
15 20
15
10
10
5 5
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
65
Fluxo de ar de purga SCFM
80
60
55 70
50
45 60
40 50
35
30 40
25 30
20
15 20
10
10
5
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
100
90
90
80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Configurao do medidor de purga PSIG
Configurao do medidor de purga PSIG
180 220
200
160
180
140
Fluxo de ar de purga SCFM
160
120 140
100 120
80 100
80
60
60
40
40
20 20
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Configurao do medidor de purga PSIG Configurao do medidor de purga PSIG
210 270
180 240
210
150
180
120 150
90 120
60 90
60
30
30
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Configurao do medidor de purga PSIG Configurao do medidor de purga PSIG
360 500
330 450
Fluxo de ar de purga SCFM
400
Fluxo de ar de purga SCFM
350
500
300
400
250
200 300
150 200
100
100
50
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Configurao do medidor de purga PSIG Configurao do medidor de purga PSIG
900 900
Fluxo de ar de purga SCFM
800 800
Fluxo de ar de purga SCFM
700 700
600 600
500 500
400
400
300
300
200
200
100
100
0
0 10 20 30 40 50 60 70 0
0 10 20 30 40 50 60 70
Configurao do medidor de purga PSIG
Configurao do medidor de purga PSIG
10.19
CL OF AIR OUTLET
(4) .56'' DIA. MTG. HOLES
CL OF AIR OUTLET
DUST PARTICULATE
AFTERFILTER
TOWER PRESSURE ELECTRICAL ENCLOSURE PURGE ADJUSTMENT VALVE
GAUGE NEMA 4
CONTROLLER & DISPLAY PANEL
(SEE DETAIL) PURGE FLOW GAUGE 1/4'' MPT AUTOMATIC DRAIN
CONNECTION
BLUE MOISTURE
INDICATOR RELIEF VALVE
HIGH EFFICIENCY
PILOT AIR FILTER
PILOT AIR SHUT-OFF
CL OF AIR INLET 1'' FPT AIR INLET
VALVE CONNECTION
1/4'' MPT AUTOMATIC DRAIN HIGH EFFICIENCY
CONNECTION 56.56 PREFILTER
http://www.ingersollrandproducts.com
PURGE MUFFLER 34.00
14.0 DISPOSIO GERAL
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
5) DRYER TO BE LIFTED BY LIFTING SUPPORT ONLY.
DISPOSIO GERAL
HL90-HL120
580000-E
23
24
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF
2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING
4) LEFT/RIGHT TOWER REGEN LEFT TOWER DRYING LIGHT
5) DEW POINT (OPTIONAL)
FACE OF AIR INLET & OUTLET 6) REGEN SEQUENCE STATUS
(OPTIONAL 3-VALVE BYPASS) 8) COMPRESSOR INTERLOCK (OPTIONAL) DRYER OFF / ALARM LIGHT
9) AUTO RESTART
2.00 TYP RIGHT TOWER REGEN LIGHT
PUSH BUTTONS RIGHT TOWER DRYING LIGHT
1) ON
2.00 (TYP) 2) OFF
3) RESET
32.56 4) TEST
5) SET
CONTROLLER & DISPLAY PANEL DETAIL
6) SELECT DISPLAY
43.75 7) ENTER
8) +/-
28.00
32.00
11.19
CL OF AIR OUTLET
34.50 FACE OF AIR OUTLET
(4) .56'' DIA. MTG. HOLES 1 1/2'' FPT AIR OUTLET
10.25 CONNECTION
20.00 (HL 200)
19.00 (HL 160)
1 1/2'' FPT AIR INLET
DESICCANT FILL PORT CONNECTION
CL OF AIR OUTLET
ELECTRICAL
TOWER PRESSURE GAUGE ENCLOSURE PURGE ADJUSTMENT VALVE
NEMA 4
CONTROLLER & DISPLAY PANEL DUST PARTICULATE
(SEE DETAIL) PURGE FLOW GAUGE
AFTERFILTER
1/4'' MPT AUTOMATIC DRAIN
BLUE MOISTURE CONNECTION
INDICATOR
RELIEF VALVE
PILOT AIR FILTER
CL OF AIR INLET
1/4'' MPT AUTOMATIC DRAIN
CONNECTION
59.50
66.12 HIGH EFFICIENCY
PREFILTER
http://www.ingersollrandproducts.com
1/4'' MPT AUTOMATIC DRAIN
PURGE MUFFLER CONNECTION
34.00
14.0 DISPOSIO GERAL
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSIO GERAL
HL160-HL200
580001-D
FACE OF AIR INLET & OUTLET LCD DISPLAY POWER ON LIGHT
(OPTIONAL 3-VALVE BYPASS) 1) DRYER ON/OFF
2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
2.00 TYP 5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
2.00 TYP
RIGHT TOWER REGEN LIGHT
PUSH BUTTONS RIGHT TOWER DRYING LIGHT
1) ON
44.19 @ HL 250 2) OFF
50.38 @ HL 300 3) RESET
4) TEST
5) SET CONTROLLER & DISPLAY PANEL DETAIL
28.00 32.00 6) SELECT DISPLAY
7) ENTER
8) +/-
10.69
CL OF AIR OUTLET
DUST PARTICULATE
AFTERFILTER
TOWER PRESSURE ELECTRICAL
GAUGE ENCLOSURE PURGE ADJUSTMENT VALVE
NEMA 4
CONTROLLER & DISPLAY PANEL PURGE FLOW GAUGE
(SEE DETAIL)
1/4'' MPT AUTOMATIC DRAIN
CONNECTION
BLUE MOISTURE
INDICATOR RELIEF VALVE
PILOT AIR FILTER
PILOT AIR SHUT-OFF
VALVE
1/4'' MPT AUTOMATIC DRAIN CL OF AIR INLET AIR INLET CONN.
CONNECTION 1 1/2'' FPT @ HL 250
2'' FPT @ HL 300
60.00
66.81
HIGH EFFICIENCY
PREFILTER
1/4'' MPT AUTOMATIC DRAIN
http://www.ingersollrandproducts.com
CONNECTION
34.00
14.0 DISPOSIO GERAL
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSIO GERAL
HL250-HL300
580002-D
25
26
38.50
LCD DISPLAY
1) DRYER ON/OFF POWER ON LIGHT
FACE OF AIR INLET & OUTLET 2) DRYER ALARM LEFT TOWER REGEN LIGHT
(OPTIONAL 3-VALVE BYPASS) 3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
50.94 2.00 TYP
32.00
11.19
CL OF AIR OUTLET
BLUE MOISTURE
INDICATOR RELIEF VALVE
1/4'' MPT AUTOMATIC
PILOT AIR FILTER DRAIN CONNECTION
L
1/4'' MPT AUTOMATIC DRAIN CL OF AIR INLET 2'' FPT AIR INLET
CONNECTION CONNECTION
60.25
67.81
HIGH EFFICIENCY
PREFILTER
http://www.ingersollrandproducts.com
34.00
1/4'' MPT AUTOMATIC
DRAIN CONNECTION
14.0 DISPOSIO GERAL
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSIO GERAL
HL400
580003-D
40.50 LCD DISPLAY
1) DRYER ON/OFF POWER ON LIGHT
2) DRYER ALARM LEFT TOWER REGEN LIGHT
FACE OF AIR INLET & OUTLET 3) LEFT/RIGHT TOWER DRYING
(OPTIONAL 3-VALVE BYPASS) 4) LEFT/RIGHT TOWER REGEN LEFT TOWER DRYING LIGHT
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
2.00 TYP
RIGHT TOWER REGEN LIGHT
54.50 @ HL500 PUSH BUTTONS RIGHT TOWER DRYING LIGHT
57.25 @ HL600 1) ON
2.00 (TYP) 2) OFF
(4) O .56 MOUNTING HOLES
3) RESET
4) TEST
5) SET CONTROLLER & DISPLAY PANEL DETAIL
6) SELECT DISPLAY
7) ENTER
8) +/-
29.00 33.00
12.19
CL OF AIR OUTLET
FACE OF AIR OUTLET
11.50
27.50 @ HL 500
30.25 @ HL 600 2'' FPT AIR OUTLET
CONNECTION
CL OF AIR OUTLET
HIGH EFFICIENCY
PREFILTER
http://www.ingersollrandproducts.com
40.00 1/4'' MPT AUTOMATIC
DRAIN CONNECTION
14.0 DISPOSIO GERAL
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSIO GERAL
HL500-HL600
580004-D
27
28
FACE OF AIR INLET & OUTLET
(OPTIONAL 3-VALVE BYPASS)
9.62 PURGE ADJUSTMENT VALVE
2.00 TYP
(4) .56''O MOUNTING HOLES 44.00 3.00 TYP FACE AIR OUTLET CL OF AIR OUTLET
CL AIR OUTLET
ELECTRICAL
ENCLOSURE
NEMA 4
http://www.ingersollrandproducts.com
PREFILTER
50.50
1/4'' MPT AUTOMATIC
14.0 DISPOSIO GERAL
DRAIN CONNECTION
2'' NPT PLUG
DESICCANT
DRAIN PORT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSIO GERAL
HL800-HL1200
580005-E
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF
2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
ELECTRICAL
ENCLOSURE CL OF AIR OUTLET
NEMA 4
RELIEF VALVE
TOWER PRESSURE
GAUGE
BLUE MOISTURE
INDICATOR
PURGE MUFFLER
PILOT AIR
SHUT-OFF 80.06 PILOT AIR FILTER
VALVE PURGE FLOW
GAUGE
56.88
CL OF AIR INLET
4'' FLANGE AIR
INLET CONNECTION
http://www.ingersollrandproducts.com
2'' NPT PLUG 24.25
DESICCANT
14.0 DISPOSIO GERAL
DRAIN PORT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSIO GERAL
HL1500
29
580006-D
30
LCD DISPLAY
1) DRYER ON/OFF POWER ON LIGHT
2) DRYER ALARM
3) LEFT/RIGHT TOWER DRYING LEFT TOWER REGEN LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL) LEFT TOWER DRYING LIGHT
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
(4) .56''O MOUNTING HOLES 54.00 3.00 2.00 TYP 22.38 CL OF AIR OUTLET 4'' 150# R.F. FLANGE
TYP AIR OUTLET CONNECTION
OUTLET CHECK OUTLET CHECK
38.12 FACE OF OUTLET VALVE VALVE
CONTROLLER AND
2'' NPT PLUG DISPLAY PANEL
DESICCANT (SEE DETAIL)
FILL PORT
CL OF AIR OUTLET
ELECTRICAL
ENCLOSURE
NEMA 4
PURGE CHECK
VALVE
PURGE CHECK
VALVE
TOWER PRESSURE
GAUGE RELIEF
BLUE VALVE
MOISTURE
91.88 INDICATOR
PURGE FLOW
GAUGE PURGE
PURGE ADJUSTMENT
MUFFLER VALVE
67.25
http://www.ingersollrandproducts.com
PILOT AIR CL OF AIR INLET
FILTER
14.0 DISPOSIO GERAL
PILOT AIR
SHUT-OFF
2'' NPT PLUG VALVE
26.12
DESICCANT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSIO GERAL
HL1800-HL2100
580029-D
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF LEFT TOWER REGEN LIGHT
2) DRYER ALARM LEFT TOWER DRYING LIGHT
3) LEFT/RIGHT TOWER DRYING
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
60.75
RIGHT TOWER REGEN LIGHT
PUSH BUTTONS RIGHT TOWER DRYING LIGHT
43.00 47.00 1) ON
2) OFF
3) RESET
4) TEST
5) SET CONTROLLER & DISPLAY PANEL DETAIL
6) SELECT DISPLAY
7) ENTER
8) +/-
2.00 (TYP)
(4) .56''O MOUNTING HOLES
3.00 (TYP)
54.00
38.25 FACE OF OUTLET 22.38 CL OF AIR OUTLET 4'' FLANGE AIR
OUTLET CONNECTION
2'' NPT PLUG
DESICCANT
FILL PORT
91.88
PURGE
ELECTRICAL ADJUSTMENT
ENCLOSURE VALVE
TOWER PRESSURE NEMA 4
GAUGE RELIEF VALVE
BLUE
MOISTURE
INDICATOR PURGE FLOW
GAUGE
PURGE
MUFFLER
PILOT AIR
FILTER
67.25
CL OF AIR INLET
http://www.ingersollrandproducts.com
4'' FLANGE AIR
INLET CONNECTION
PILOT AIR
14.0 DISPOSIO GERAL
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSIO GERAL
HL2700
31
580007-D
32
5.88
60.00
(4) .56''O MOUNTING HOLES 1.50 (TYP) PILOT AIR FILTER
63.00
CLOF OUTLET
66.00
6'' RAISED FLANGE 150#
41.38 FACE OF OUTLET AIR OUTLET CONNECTION
23.00
CHECK VALVE
DESICCANT
FILL PORT
CL OF AIR OUTLET
100.00
PURGE FLOW
BLUE MOISTURE GAUGE
INDICATOR CL OF AIR INLET
6'' FLUSH FLANGE 125#
72.25 AIR INLET CONNECTION
http://www.ingersollrandproducts.com
PURGE VALVE
14.0 DISPOSIO GERAL
FLOW VALVE
34.00
DO NOT LIFT HERE
PURGE MUFFLER
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
5) FILTER PACKAGES SHIPPED SEPARATELY.
FILTER PIPING SUPPORT, IF REQUIRED, TO BE
SUPPLIED BY CUSTOMER.
DISPOSIO GERAL
HL3300-HL4000
580092-E
12.00
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF
CL OF MOUNTING HOLE 2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
7) COMPRESSOR INTERLOCK
8) AUTO RESTART DRYER OFF / ALARM LIGHT
32.50
6.00 (TYP)
CL OF MOUNTING HOLE
PILOT AIR FILTER
60.00
(4) O .62 MOUNTING HOLES 1.50 (TYP)
63.00
ELECTRICAL
CONTROLLER AND ENCLOSURE CL OF AIR OUTLET
DISPLAY PANEL NEMA 4
(SEE DETAIL)
TOWER PRESSURE
GAUGE PURGE ADJUSTMENT
VALVE
TOWER RELIEF
VALVE
http://www.ingersollrandproducts.com
CL OF AIR INLET
64.00
PURGE VALVE
14.0 DISPOSIO GERAL
FLOW VALVE
34.75
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
5) FILTER PACKAGES SHIPPED SEPARATELY.
FILTER PIPING SUPPORT, IF REQUIRED, TO BE
SUPPLIED BY CUSTOMER.
DISPOSIO GERAL
HL5000
580306-B
33
15.0 DIAGRAMA DE FIAO
DIAGRAMA DE FIAO
HL90-HL5000
TM-580078-C
DIAGRAMA DE FLUXO
HL90-HL2700
580022-E
DIAGRAMA DE FLUXO
HL3300-HL5000
580213-C
DESSECANTE, 4-8 mm, TIPO D NOTE 1 NOTE 1 NOTE 1 NOTE 1 NOTE 1 NOTE 1
Sobressalentes. Os valores sob esse ttulo refletem a quantidade para cada componente que recomendamos que tenha mo para
manuteno ou reparos. A quantidade apropriada para a sua aplicao depender do quo crticas as interrupes do funcionamento so
para a sua operao.
Tipo Quantidade Sugerida para:
1 Mnima Servio interno, no qual interrupes do servio so aceitveis.
2 Mdia Servio interno, no qual algumas interrupes do servio so aceitveis.
3 Mximo Servio de exportao ou interno no qual interrupes do servio no so aceitveis.
Sobressalentes. Os valores sob esse ttulo refletem a quantidade para cada componente que recomendamos que tenha mo para
manuteno ou reparos. A quantidade apropriada para a sua aplicao depender do quo crticas as interrupes do funcionamento so
para a sua operao.
Tipo Quantidade Sugerida para:
1 Mnima Servio interno, no qual interrupes do servio so aceitveis.
2 Mdia Servio interno, no qual algumas interrupes do servio so aceitveis.
3 Mximo Servio de exportao ou interno no qual interrupes do servio no so aceitveis.
DESSECANTE, 4-8 mm, TIPO D NOTE 1 NOTE 1 NOTE 1 NOTE 1 NOTE 1 NOTE 1
MANMETRO, PRESSO DE
38052973 38052973 38052973 38052973 38052973 3
PURGA/TORRE 3 1/2 pol.
CONTROLADOR LGICO
38054185 38054185 38054185 38054185 38054185 1 1 1 1
PROGRAMVEL
VLVULA, ESFERA, PURGA, 1 1/2 pol. 38054052 38054052 38054052 38054052 38054052 1
VLVULA, RETENO, PURGA, 1 1/2 pol. 23354582 38052643 38052643 38052643 38052643 2
Sobressalentes. Os valores sob esse ttulo refletem a quantidade para cada componente que recomendamos que tenha mo para
manuteno ou reparos. A quantidade apropriada para a sua aplicao depender do quo crticas as interrupes do funcionamento so
para a sua operao.
Tipo Quantidade Sugerida para:
1 Mnima Servio interno, no qual interrupes do servio so aceitveis.
2 Mdia Servio interno, no qual algumas interrupes do servio so aceitveis.
3 Mximo Servio de exportao ou interno no qual interrupes do servio no so aceitveis.
MANMETRO, PRESSO DE
38052973 38052973 38052973 38052973 3
PURGA/TORRE 3 1/2 pol.
SILENCIADOR, DESCARGA, 2 pol. 38054045 38054045 38054045 38054045 2 2 2 2
Sobressalentes. Os valores sob esse ttulo refletem a quantidade para cada componente que recomendamos que tenha mo para
manuteno ou reparos. A quantidade apropriada para a sua aplicao depender do quo crticas as interrupes do funcionamento so
para a sua operao.
Tipo Quantidade Sugerida para:
1 Mnima Servio interno, no qual interrupes do servio so aceitveis.
2 Mdia Servio interno, no qual algumas interrupes do servio so aceitveis.
3 Mximo Servio de exportao ou interno no qual interrupes do servio no so aceitveis.
DESCRIO DA VLVULA CCN DA VLVULA* CCN DO KIT DE VEDAES CCN DO KIT DE PEAS
VLVULA, DIAFRAGMA, 3/4 pol., O.P.N.F. 38446894 38052114 38052635
VLVULA, DIAFRAGMA, 1 pol., O.P.N.F. 38052940 38052114 38052635
VLVULA, DIAFRAGMA, 1 1/2 pol., O.P.N.F. 38052932 38052668 38052825
VLVULA, DIAFRAGMA, 2 pol., O.P.N.F. 38053088 38052866 38052965
VLVULA, DIAFRAGMA, 1 pol., O.P.N.A. 38453833 38052114 38052619
VLVULA, DIAFRAGMA, 1 1/2 pol., O.P.N.A. 38052957 38052668 38052783
VLVULA, DIAFRAGMA, 2 pol., O.P.N.A. 38053070 38052866 38052882
VLVULA, DIAFRAGMA, 3 pol., O.P.N.A. 38052981 38053005 38053013
VLVULA, DIAFRAGMA, 4 pol., O.P.N.A. 38052924 38053021 38053039
COMPONENTES DO EMS
DESCRIO CCN
DESCRIO DA VLVULA VALVE W/ ACT VLVULA S KIT REPARO VLVULA ATUADOR ATUADOR KIT
MODEL Fluxo de Fluxo de Fluxo Largura pol Profundidade Profundidade Altura pol. Conex Peso de Peso de
O entrada entrada para de pol. sem pol. com desvio o de remessa lb. dessecante por
para ponto ponto de purga desvio entrada secador lb.
de orvalho orvalho - SCFM e sada
-40F 100F SCFM de ar
SCFM
HL90 90 72 14 40.5 (102.9) 30 (76.2) 37.5 (95.3) 63 12 (160.3) 1 475 (213) 100 (45)
HL120 120 96 19 40.5 (102.9) 30 (76.2) 37.5 (95.3) 63 12 (160.3) 1 563 (255) 134 (61)
HL160 160 128 26 44.5 (113) 32 (81.3) 43.75 (111.1) 66.12 (167.9) 1 1/2 707 (321) 192 (87)
HL200 200 160 30 44.5 (113) 32 (81.3) 43.75 (111.1) 66.12 (167.9) 1 1/2 731 (332) 236 (107)
HL250 250 200 40 48.5 (123.2) 32 (81.3) 44.19 (112.2) 66.81 (169.7) 1 1/2 869 (394) 290 (132)
HL300 300 240 48 48.5 (123.2) 32 (81.3) 50.38 (128.0) 66.81 (169.7) 2 924 (419) 344 (156)
HL400 400 320 65 52.5 (133.4) 36.19 (91.9) 50.94 (129.4) 67.81 (172.2) 2 1115 (506) 470 (213)
HL500 500 400 81 56.5 (143.5) 39.69 (100.8) 54.5 (138.4) 82.5 (209.6) 2 1564 (709) 638 (289)
HL600 600 480 93 56.5 (143.5) 42.4 (107.8) 57.25 (145.4) 82.5 (209.6) 2 1664 (755) 748 (339)
HL800 800 640 130 64 (162.6) 51.25 (130.2) 64.38 (163.5) 87.62 (222.6) 3 2017 (915) 900 (408)
HL1000 1000 800 162 64 (162.6) 51.25 (130.2) 64.38 (163.5) 87.62 (222.6) 3 2237 (1015) 1100 (499)
HL1200 1200 960 195 64 (162.6) 51.25 (130.2) 64.38 (163.5) 87.62 (222.6) 3 2424 (1100) 1270 (576)
HL1500 1500 1200 243 78 (198.1) 54.76 (139.1) N/A 80 (203.2) 4 2974 (1349) 1600 (726)
HL1800 1800 1440 292 84 (213.4) 60.62 (154.0) N/A 91.88 (233.4) 4 3905 (1771) 2000 (907)
HL2100 2100 1680 340 84 (213.4) 60.62 (154.0) N/A 91.88 (233.4) 4 4279 (1941) 2340 (1062)
HL2700 2700 2160 438 84 (213.4) 60.76 (154.3) N/A 91.88 (233.4) 4 4926 (2234) 2928 (1328)
HL3300 3300 2640 535 96 (244) 66 (167.6) N/A 100 (254) 6 2950 (1338) 3800 (1723) *
HL4000 4000 3200 649 96 (244) 66 (167.6) N/A 100 (254) 6 3000 (1361) 4226 (1917) *
HL5000 5000 4000 811 102 (259) 72 (183) N/A 92 (233.7) 6 3950 (1792) 5138 (2330) *
Nota: Todos os secadores acima foram classificados para temperatura de entrada mxima de 120F, 150 PSIG.
A capacidade e o fluxo de purga tm como base condies padro de entrada (100 PSIG e 100F), e iro variar com
condies da entrada diferentes.
AVISO
As informaes sobre especificaes acima eram exatas no momento da publicao. Consulte
a etiqueta de srie do equipamento para as especificaes especficas para aquela unidade.
C.C.N. : 80442833 es
FECHA : ABRIL 2010
MOD. : D
NDICE
NDICE PGINA NDICE PGINA
Las secadoras desecantes sin calor Ingersoll Rand estn diseadas despresurizacin inicial rpida, una parte del aire seco de la torre en
para adsorber la humedad de aire comprimido. Las secadoras se lnea pasa sobre la capa de desecante y transporta la humedad fuera
fabrican con dos torres, las cuales contienen capas de desecante. Ellas de ella y sale por el escape de la secadora.
alternan entre los modos en lnea (secado) y fuera de lnea
(regeneracin), produciendo un flujo continuo de aire seco en la salida El proceso continuo y alternado de adsorcin y desorcin se controla
de la secadora. con un temporizador que conmuta las torres en una secuencia de
tiempo especfica. Se logran puntos de condensacin de aire
Durante el funcionamiento normal el aire hmedo pasa por la torre en comprimido muy seco por medio de la conmutacin y el funcionamiento
lnea, y se adsorbe (recolecta) el vapor de agua en las capas de continuo de esta secadora. Ingersoll Rand ofrece secadoras para
desecante. Mientras se adsorbe el aire en la torre en lnea, la humedad proporcionar aire de salida con un punto de condensacin de presin de
presente en el desecante en la torre fuera de lnea se elimina por medio -40 F o -100 F.
de un proceso llamado desorcin (regeneracin). Luego de una
3.0 GARANTA
Ingersoll-Rand Company Limited garantiza que los equipos que fabrica encuentre limitada a pruebas especficas, la obligacin de la Compaa
y distribuye conforme a este documento estarn libres de defectos tanto ser corregirla de la manera y dentro del plazo estipulado
de materiales como de mano de obra, durante un perodo de doce anteriormente.
meses desde la fecha en que los Equipos se ponen en funcionamiento
o de dieciocho meses desde la fecha de envo desde la fbrica, lo que LA COMPAA NO OTORGA NINGN OTRO TIPO DE GARANTA NI
suceda primero. El Comprador estar obligado a informar REALIZA NINGUNA DECLARACIN, EXPRESA O IMPLCITA, SALVO
oportunamente y por escrito a la Compaa de cualquier tipo de LA DEL TTULO, Y POR MEDIO DE ESTE DOCUMENTO SE NIEGAN
incumplimiento de las condiciones de esta garanta dentro de dicho TODAS LAS GARANTAS IMPLCITAS DE COMERCIABILIDAD E
perodo, y la Compaa corregir, a su discrecin, dicho incumplimiento IDONEIDAD PARA UN FIN EN PARTICULAR.
reparando el equipo en forma apropiada, o proporcionar una pieza de
repuesto F.O.B. en el punto de embarque, siempre y cuando el La correccin de los incumplimientos por parte de la Compaa, sean
Comprador haya almacenado, instalado, mantenido y operado dichos patentes o latentes, en la forma y el plazo estipulado anteriormente,
Equipos en conformidad con las buenas prcticas industriales y haya debern constituir el cumplimiento de todas las responsabilidades de la
cumplido con las recomendaciones especficas de la Compaa. Los Compaa, para aquellos incumplimientos que se basen ya sea en el
accesorios o equipos que proporcione la Compaa pero que fabriquen contrato, negligencia de la garanta, indemnizacin, responsabilidad
terceros, mantendrn cualquier garanta que los fabricantes hayan absoluta u otros relativos a o que se deriven de dichos Equipos.
traspasado a la Compaa y que se pueda transferir al Comprador. La
Compaa no ser responsable de reparaciones, reemplazos o ajustes El Comprador no operar los Equipos que se consideren defectuosos,
a los Equipos ni de ningn tipo de costo por mano de obra en que sin notificar por escrito primeramente a la Compaa de su intencin de
incurra el Comprador u otras personas que no cuenten con la previa hacerlo. Cualquier uso tal de los Equipos ser bajo el riesgo y
autorizacin por escrito de la Compaa. responsabilidad exclusivos del Comprador.
Se excluyen especficamente de esta garanta los efectos de la Observe que sta es una garanta estndar de Ingersoll Rand.
corrosin, erosin y del desgaste normal. Las garantas de Cualquier garanta vigente al momento de la compra del equipo o que
cumplimiento se encuentran limitadas a las que se indican se haya negociado como parte de la orden de compra podr tener
especficamente dentro de la propuesta de la Compaa. A menos que precedencia sobre esta garanta.
la responsabilidad de cumplir tales garantas de rendimiento se
* Los flujos nominales que se indican son para una temperatura de entrada de 100 F, una temperatura ambiente de 100 F y una presin de aire
comprimido de 100 psig.
AVISO
La nomenclatura que se muestra anteriormente representa las opciones estndar de la lista
de precios. Hay otras opciones disponibles. Consulte el inserto con la nomenclatura especfica
de su secadora para obtener detalles.
5.1 INSPECCIN Consulte las etiquetas de la secadora para obtener los medios
Al recibir su secadora de aire Ingersoll Rand, revise la unidad apropiados para levantar o mover la secadora. Cuando levante la
detenidamente. Si detecta una manipulacin descuidada, haga la secadora, asegrese de que no se aplique tensin sobre las tuberas o
observacin en su recibo de entrega, especialmente si la secadora no las vlvulas. Consulte la Seccin 9.2 para ubicar e instalar la secadora.
se desembalar inmediatamente. Es recomendable obtener la firma de
la persona que entregue el producto por cualquier dao que pueda
observar a fin de facilitar cualquier reclamacin de seguros.
5.2 DESEMBALAJE Y MANIPULACIN
ADVERTENCIA
Ninguna persona debe tratar de levantar objetos pesados sin los
equipos adecuados para este fin (es decir, gras, montacargas,
eslingas u horquillas elevadoras) bajo ninguna circunstancia. El
levantamiento de cualquier unidad sin los equipos adecuados puede
causar lesiones graves.
PRESS ON
o botn en blanco
Permite que el usuario retroceda al nivel anterior del men.
Condicin de alarma
Figura 3 Detalles de la
pantalla de alarmas
Modo de reinicio automtico (LAST) Al presionar el botn SELECT DISPLAY aparecen las horas
acumuladas en que la secadora ha usado aire de purga.
En este modo, la secadora se iniciar automticamente una
vez que se le vuelva a suministrar energa. El control de
microprocesador se iniciar donde qued en el programa una
vez que se suministre energa.
BEGIN TIMES
SELECT
7.8.4.2 Horas de funcionamiento DISPLAY
En MODO CLIENTE, el controlador de microprocesador
otorga acceso a las horas de funcionamiento de la secadora.
A continuacin se describe el mtodo de acceso y revisin de Al presionar el botn ENTER regresa la pantalla a la parte
las horas de funcionamiento y de purga de la secadora: superior del men OPERATING TIMES.
La secadora nunca se debe instalar en lugares en que la temperatura Instale las tuberas de aire comprimido en las conexiones de entrada y
del aire o ambiente supere los 120 F o sea inferior a +50 F. Ubique la salida. Ubique los prefiltros lo ms cerca posible de la secadora.
secadora de modo que evite las temperaturas extremas de calor y fro Asegrese de que la ubicacin no interfiera con un mantenimiento fcil.
producto del ambiente u otras condiciones. Evite colocar la secadora en Consulte el plano Disposicin general.
el exterior o en lugares expuestos a los agentes naturales.
Tenga en cuenta que la entrada de aire hmedo se encuentra en el
AVISO mltiple inferior de la secadora, mientras que la salida de aire seco est
Ingersoll Rand recomienda limpiar los silenciadores despus de la en el mltiple superior de la misma. En los casos en que se requiera un
puesta en marcha inicial para eliminar cualquier polvo desecante que suministro de aire las 24 horas del da (no es aconsejable interrumpir el
se genere durante el envo. Despus de hacer funcionar la secadora flujo de aire), se recomienda un sistema de derivacin de tres vlvulas
durante un perodo inicial de 30 minutos, desconecte/despresurcela y para pasar por alto la secadora. Use la menor cantidad de codos
retire los silenciadores. Desarme y limpie el inserto desmontable que posibles para mantener al mnimo la cada de presin.
se encuentra en el interior del silenciador. Vuelva a instalar los Una vez que se hayan conectado todas las tuberas, se debe efectuar
silenciadores antes de operar la secadora.
Secadora desecante serie HL, modelos 90-5000 9
http://www.ingersollrandproducts.com
9.0 INSTALACIN Y PUESTA EN MARCHA
una prueba con burbujas de jabn a todas las uniones (incluso las de la 9.5 INSTALACIN DEL TRANSMISOR DE PUNTO DE ROCO
secadora) en la presin de lnea para garantizar que no se haya daado (OPCIONAL)
ninguna de ellas durante el transporte y la instalacin en terreno.
En secadores equipados con EMS, el transmisor de punto de roco se
9.4 FILTRACIN enva en un contenedor distinto dentro de la carcasa elctrica para
proteger al transmisor durante el transporte. Antes de utilizar la funcin
Es importante que se proporcione un prefiltro y un postfiltro en la EMS, el transmisor debe ser instalado en el bloque de sensores situado
instalacin de la secadora. Todas las secadoras se proporcionan con un en el lado de o detrs de la carcasa elctrica y fijar el cable del
prefiltro y postfiltro de fbrica. stos vienen instalados en los modelos transmisor en el sensor. Tenga en cuenta que el transmisor slo debe
HL1200 y ms pequeos, y se envan por separado en los modelos ser instalado cuando el secador est listo para su puesta en marcha.
HL1500 y ms grandes.
Para instalar el Transmisor de punto de roco:
AVISO
Todas las secadoras deben contar con la filtracin adecuada. Como o Saque el Transmisor de su embalaje original.
mnimo, se debe usar un filtro de coalescencia de 0,3 micrones con
drenaje y particulado automtico. Si no se proporciona la filtracin o Verifique que la arandela est colocada bajo el hex del Transmisor.
adecuada para la secadora, se anular la garanta.
o Enrosque el Transmisor al bloque de sensores segn la ilustracin.
Los prefiltros de coalescencia, ubicados antes de la secadora, protegen
las capas de desecante de la contaminacin por aceite, agua o Conecte el cable del Transmisor al Transmisor. Asegrese de apretar
arrastrada, oxidacin de las tuberas, etc., lo que prolonga la vida til del del todo el tornillo de seguro del cable del Transmisor en la rosca de
desecante de la secadora. Ubique los prefiltros lo ms cerca posible de acople del Transmisor.
la secadora.
TRANSMISOR CABLE
ASEGURAR SCREW
TRANSMISOR CABLE
TRANSMISOR
WASHER
AVISO AVISO
La secadora debe conectarse a tierra con un conductor de tierra de Cuando abra la vlvula de salida, asegrese de que el indicador de la
tamao completo conectado a una puesta a tierra. torre de secado mantenga la presin de lnea. Permitir que baje la
presin en la secadora provocar una condicin de desbordamiento.
AVISO
AVISO
La secadora debe contar con fusibles de acuerdo con la norma de
NEC con el fusible de tamao que se indica en la placa de Las secadoras de -100 F requieren un flujo por la secadora para
identificacin serial de la secadora o en la hoja de especificaciones del reducir el punto de condensacin de presin a los niveles de diseo.
manual tcnico. Si no se permite que fluya aire por la secadora (viaje sin carga) se
producirn puntos de condensacin elevados en la salida. Una vez
Ajuste el tamao de los agujeros ciegos de conexin de campo para los que se permite que el aire fluya por la secadora, el punto de
accesorios del conducto para cables segn NEC. condensacin de presin se reducir gradualmente hasta los niveles
de diseo.
9.7 VERIFICACIN DEL NIVEL DE DESECANTE
Retire el orificio de llenado de desecante y la parte superior del 9.9 SECUENCIA DE APAGADO
recipiente de desecante y compruebe el nivel de ste. El nivel debe
concordar con el nivel que se indica en la Tabla de llenado de desecante
que se encuentra al final del manual. La carga inicial de desecante se AVISO
instala en fbrica en las secadoras. on models Antes de desconectar la secadora o extraer aire comprimido de ella,
HL 2700 and syaller. presione el botn OFF del control de microprocesador. Ello inicia la
secuencia de apagado, que cierra las vlvulas de purga, vuelve a
9.8 PUESTA EN MARCHA presurizar la torre fuera de lnea y abre las vlvulas de flujo. NO
Presurice lentamente la secadora. Cuando sta alcance la presin de DESCONECTE LA SECADORA NI EXTRAIGA AIRE COMPRIMIDO
funcionamiento, compruebe que el sistema no presente filtraciones de DE ELLA DURANTE LA SECUENCIA DE APAGADO.
aire. Efecte una prueba con jabn en todas las uniones y accesorios.
Para mantener el punto de condensacin que desee, se deben Mantenga una fuente de aire comprimido en la secadora y un
corregir todas las filtraciones que se detecten, en especial las que se suministro de energa en el controlador de microprocesador.
encuentren en el lado de salida de la secadora.
Asegrese de que la vlvula de ajuste de purga est abierta y que la
vlvula de retencin de salida (si est instalada) est cerrada. SHUTDOWN
Para las secadoras que cuentan con EMS, retire del alojamiento elctrico OFF
el sensor del monitor del punto de condensacin e instlelo en el bloque de SEQUENCE
deteccin, que se encuentra a un costado del alojamiento y conecte el
cable del sensor al sensor. Presione el botn OFF para iniciar la SECUENCIA DE
Active el interruptor de desconexin de la secadora (proporcionado por el APAGADO (Shutdown sequence).
cliente) para alimentar energa a la secadora. Se encender la pantalla
LCD en el controlador de microprocesador. Permita que la secadora complete toda la SECUENCIA DE APAGADO
Arranque la secadora presionando el botn ON en el controlador de (30 segundos).
microprocesador.
Durante los primeros 30 segundos que la secadora est activada, PRESS ON
permanecern cerradas las dos vlvulas de purga. Despus de dicho
tiempo, se abrir la vlvula de purga de la torre izquierda y se producir la
despresurizacin de la torre izquierda.
Con un voltmetro, verifique que las conexiones elctricas tengan el voltaje Una vez que aparezca el mensaje PRESS ON, significa que
correcto que aparece en la placa de identificacin serial de la secadora. la secadora termin la SECUENCIA DE APAGADO. La
Cierre y fije todas las cubiertas del tablero elctrico. secadora se puede desconectar y se puede extraer aire de
El controlador de microprocesador indicar que la torre izquierda est ella con seguridad.
secando.
La secadora funcionar en la secuencia que se describe en la Seccin 7. Desconecte la secadora.
A continuacin de la despresurizacin, ajuste la vlvula de purga segn lo
que se describe en la Seccin 7.4.
Apague el compresor de aire o pase por alto la secadora.
AVISO
Cierre las vlvulas de aislamiento (si estn instaladas).
En la puesta en marcha inicial, revise el funcionamiento de la secadora
durante uno o dos ciclos, especialmente en el momento del cambio de
torre. Verifique que todos los sistemas funcionen en el orden y secuencia Nota: En la siguiente puesta en marcha, la vlvula de aislamiento debe
correctos. Si la secadora no funciona de forma adecuada, comunquese estar en la posicin de cierre. brala lentamente para acumular presin
con el distribuidor o con el Servicio Tcnico de Ingersoll Rand. descendente.
En el MODO TCNICO, se pueden visualizar, pero no cambiar, los Lo siguiente ilustra el mtodo de acceso y ajuste de la caracterstica de
siguientes parmetros: regulador de punto de condensacin.
Parmetro Pantalla
SELECT
PDP ADJUSTER
MODO DE FUNCIONAMIENTO HEATLESS
* NOTA: Los puntos de referencia indicados SLO se pueden ajustar
DISPLAY DEW POINT: -40
si la secadora cuenta con el EMS. stos no se pueden ajustar en
secadoras que no cuenten con esta opcin. Presione el botn SELECT DISPLAY hasta que aparezca la
pantalla DEW POINT ADJUSTER (Regulador de punto de
10.1 INGRESO AL MODO TCNICO condensacin).
ADVERTENCIA +
PDP ADJUSTER
Slo personal de servicio calificado debe ingresar al MODO - DEW POINT: -4
TCNICO. La modificacin de los puntos de referencia del MODO
TCNICO afectar considerablemente el funcionamiento de la Presione el botn +/- hasta que aparezca el punto de
secadora. Los puntos de referencia incorrectos pueden daar la condensacin que desee. Al presionar SELECT DISPLAY se
secadora y provocar posibles lesiones graves. guarda la seleccin actual.
Para ingresar al MODO TCNICO, presione los siguientes botones: 10.3 SISTEMA DE ADMINISTRACIN DE ENERGA (OPCIONAL)
10.3.1 DESCRIPCIN Y ACTIVACIN
El sistema de administracin de energa (EMS) opcional se
BEGIN dise para minimizar la prdida de aire de purga durante
2 3 TECHNICIAN MODE condiciones de carga de flujo bajo o bajo nivel de agua. Un
sensor digital de punto de condensacin detecta el punto de
condensacin de presin de aire de la salida real del aire de
Al presionar simultneamente los botones 2 y 3 ingresa al proceso. El sensor le comunica la lectura del punto de
MODO TCNICO. condensacin de presin al controlador de microprocesador.
Si el punto de condensacin de presin es inferior al punto de
SELECT
EMS: OFF 1 EMS SET POINT
DISPLAY
-41_
Presione el botn SELECT DISPLAY hasta que aparezca la Use los nmeros del teclado para ingresar la temperatura del
pantalla ENERGY MANAGEMENT SYSTEM (Sistema de punto de condensacin de presin que desee para el punto
administracin de energa). de referencia del EMS.
+
- EMS: ON EMS SET POINT
ENTER
-41
Presione el botn +/- hasta que aparezca el punto de
referencia que desee. Al presionar SELECT DISPLAY se Al presionar ENTER se guarda el punto de referencia
guarda la seleccin actual. seleccionado.
SELECT
EMS SET POINT secadora se puede configurar para la operacin manual
(predeterminada en fbrica) o el reinicio automtico, lo que permite que
DISPLAY -43 la secadora se inicie automticamente una vez que se vuelva a
alimentar energa a la misma. Lo siguiente ilustra el mtodo de acceso
Presione el botn SELECT DISPLAY hasta que aparezca la y ajuste de los distintos modos de inicio de la secadora:
pantalla EMS SET POINT (Punto de referencia del EMS).
RESTART
EMS SET POINT SELECT
SET DISPLAY ZERO
___
Presione el botn SELECT DISPLAY hasta que aparezca la
Al presionar el botn SET se puede cambiar el valor de EMS pantalla START MODE (Modo de inicio).
SETPOINT.
+ RESTART
+ EMS SET POINT -
- LAST
-___
Para cambiar el modo de inicio de su seleccin actual a la
Para ingresar un nmero negativo, presione el botn +/-. De configuracin alternativa, presione el botn +/- hasta que
lo contrario, contine con el siguiente paso. aparezca el punto de referencia. Al presionar SELECT
DISPLAY se guarda la seleccin actual.
SELECT
PURGE ADJUST Lo siguiente ilustra el mtodo de activacin de la
caracterstica de alarma de punto de condensacin alto:
DISPLAY % PRG SELECT 100
Presione el botn SELECT DISPLAY hasta que aparezca la
SELECT
HIGH DEW PT
pantalla PURGE FLOW ADJUSTER (Regulador de flujo
de purga).
DISPLAY OFF
Presione el botn SELECT DISPLAY hasta que aparezca la
+ PURGE ADJUST pantalla HIGH DEW POINT.
-
% PRG SELECT 70
Presione el botn +/- hasta que aparezca el porcentaje de + HIGH DEW PT
-
purga que desee. Al presionar SELECT DISPLAY se guarda ON
la seleccin actual.
Presione el botn +/- hasta que aparezca el punto de
AVISO referencia que desee. Al presionar SELECT DISPLAY se
En las secadoras que cuenten con la caracterstica de sistema de guarda la seleccin actual.
administracin de energa, el regulador de flujo de purga DEBE
configurarse en 100% con el fin de que dicho sistema funcione 10.7.2 AJUSTE DEL PUNTO DE REFERENCIA
correctamente. En secadoras que cuenten con el EMS opcional, se puede
ajustar el punto de referencia de alarma de punto de
10.6 INTERBLOQUEO DEL COMPRESOR condensacin alto.
El interbloqueo del compresor ajusta el funcionamiento de la secadora Lo siguiente ilustra el mtodo de ajuste del punto de
para que slo purgue cuando el compresor de aire est en LOADING u referencia para la caracterstica de alarma de punto de
ON. Esta caracterstica requiere que el cliente proporcione un rel en el condensacin alto:
compresor de aire para indicar si el compresor de aire est en
LOADING u ON en oposicin a UNLOADING u OFF. Antes de utilizar
esta caracterstica, el usuario debe conectar el rel a la regleta de SELECT
HI PDP SETPOINT
terminales de 5 V CC en el alojamiento elctrico de la secadora. La
secadora proporcionar la energa de 5 V CC. La seal ON o LOAD del
DISPLAY -10
compresor de aire debe coincidir con el rel abierto. La seal OFF o
UNLOAD debe coincidir con el rel cerrado. Presione el botn SELECT DISPLAY hasta que aparezca la
pantalla HIGH DEW POINT ALARM SET POINT (Punto de
Con el interbloqueo del compresor configurado y activado referencia de alarma de punto de condensacin alto).
correctamente, las vlvulas de purga de la secadora se cerrarn
cuando el compresor de aire no genere aire, como se indica mediante
la condicin OFF o UNLOAD. Con el ciclo de purga correspondiente a HI PDP SETPOINT
SET
las demandas de la secadora de aire, los ciclos del compresor de aire
se reducen y se producen ahorros de energa con slo purgar cuando
___
el sistema lo requiera.
Presionar el botn SET permite cambiar el valor de HIGH
Lo siguiente ilustra el mtodo de acceso y ajuste de la caracterstica de DEW POINT ALARM SET POINT.
interbloqueo del compresor.
+
COMP INTERLOCK
- ON
Presione el botn +/- hasta que aparezca el punto de
referencia que desee. Al presionar SELECT DISPLAY se
guarda la seleccin actual.
HI PDP SETPOINT
ENTER
-21
Al presionar ENTER se guarda el punto de referencia
seleccionado.
11.3 VLVULAS DE DRENAJE SIN PRDIDAS PARA EL CONTROL 11.8 PROCEDIMIENTO DE CAMBIO DE DESECANTE
DEL AIRE DEL PILOTO Cuando sea necesario reemplazar el desecante en las torres, siga el
El perodo de tiempo en que las vlvulas de aire del piloto pueden siguiente procedimiento:
funcionar de manera confiable sin necesitar reemplazo depende del tipo
de secadora y de su funcionamiento. En secadoras Ingersoll Rand de ADVERTENCIA
punto de condensacin -40 F, se recomienda reemplazar las vlvulas
cada 60 meses. Debido a la diferencia en los tiempos de ciclo para Para evitar lesiones, despresurice la secadora antes de realizar
unidades de -100 F, a estas secadoras se les deben reemplazar las cualquier trabajo de servicio.
vlvulas piloto cada 30 meses.
PRECAUCIN
11.4 PROCEDIMIENTO DE CAMBIO DE SILENCIADOR
Asegrese de usar proteccin respiratoria durante el proceso de
drenaje y llenado para minimizar la inhalacin de desecante, ya que
ADVERTENCIA este elemento producir polvo durante este procedimiento.
Para evitar lesiones, despresurice la secadora antes de realizar AVISO
cualquier mantenimiento.
Cada secadora se enva con un equipo de muestra de desecante para
Apague el control de encendido para despresurizar la secadora. permitir que el desecante se enve para su anlisis. Este equipo se
puede usar para verificar el estado del desecante mediante anlisis de
Reemplace el silenciador. laboratorio. Siga las instrucciones que se encuentran en el equipo.
Siga el procedimiento de puesta en marcha que se describe en la
Seccin 9.7. Las unidades estndar se proporcionan con orificios de llenado y
drenaje en cada torre desecante. Retire las tapas de ambos orificios.
Vuelva a encender el control de encendido.
Para facilitar el flujo del desecante desde la torre, inserte una varilla
pequea en el orificio de drenaje segn sea necesario. Esto puede ser
11.5 VLVULAS DE DIAFRAGMA DE PURGA Y CONMUTACIN
necesario, ya que el desecante est empaquetado en las torres, lo que
(HL90 - HL2700)
puede interferir con el flujo de desecante desde las torres.
Estas vlvulas tienen dos orificios de control, uno en la parte superior y
Las rejillas de retencin, que se encuentran en las conexiones de
otro en la parte posterior.
tuberas de entrada y salida de la torre, son desmontables en todos los
modelos. Se sugiere que estas rejillas se retiren y limpien al momento
Vlvulas normalmente abiertas (NA): Para vlvulas de entrada o
de cambiar el desecante. A estas rejillas se puede acceder
represurizacin NA, se proporciona aire de control al orificio superior.
desconectando los mltiples superior e inferior de las torres de la
El orificio posterior sirve de escape a la parte inferior del diafragma. Si
secadora.
el aire se filtra constantemente cuando se suministra aire de control a
la vlvula, los sellos internos presentan filtraciones y se deben Despus de limpiar las rejillas de retencin, reemplcelas y vuelva a
reemplazar. colocar el tapn del orificio de salida.
Sin el tapn del orificio de llenado, llene la torre de la secadora con el
Vlvulas normalmente cerradas (NC): Para vlvulas de purga NC, el desecante del grado y tamao adecuado. El nivel del desecante debe
orificio superior est cerrado. El aire de control se suministra al orificio estar por debajo de la rejilla retenedora superior, como se muestra en
posterior. Si el aire sale constantemente por el orificio posterior la Tabla de llenado de desecante que aparece a continuacin.
cuando se desconecta el solenoide, escapar por la parte superior del
solenoide. Si se produce esta condicin, los sellos internos presentan Luego de que se hayan llenado las torres, vuelva a colocar el tapn
filtraciones y se deben reemplazar. del orificio de llenado en cada una de ellas.
A todas las conexiones que participen en el proceso de cambio de
11.6 ACTUADOR ACCIONADO POR PILOTO (HL3300 - HL5000) desecante se les debe realizar pruebas de filtraciones antes de volver
a poner en servicio la secadora.
Si el actuador no gira, desconecte las tuberas del piloto para revisar
si
el actuador recibe presin del piloto.
Si el actuador recibe presin:
Verifique que la presin de control sea de 75 psig como mnimo.
Asegrese de que la vlvula de entrada no est obstruida.
Consulte las descripciones de mantenimiento que aparecen en la Seccin 11, segn se requiere para los procedimientos de localizacin de fallas.
Punto de condensacin elevado Velocidad de purga insuficiente. Verifique la configuracin del flujo de purga.
Temperatura de entrada mayor que la Revise el posenfriador, lmpielo y realice el servicio que
condicin de diseo (120 F). sea necesario.
No hay aire del piloto. Revise la tubera de aire del piloto. Compruebe que est
limpio el filtro de la tubera de aire de control.
Error del sello de la vlvula de diafragma
accionada por el piloto. Inspeccione y reemplace los sellos segn sea necesario.
La secadora no se presuriza. Vlvula de purga defectuosa. Verifique que el circuito de represurizacin enve la seal
de control.
Revise la vlvula de purga y su vlvula de drenaje sin
prdidas.
La secadora se despresuriza No se cierra la vlvula de purga; la secadora Revise la vlvula de purga y su vlvula de drenaje sin
rpidamente. se represuriza por la vlvula de entrada. prdidas.
La secadora no se purga. No se abre la vlvula de purga. La vlvula de Revise la vlvula de purga y su vlvula de drenaje sin
purga est atascada en la posicin cerrada. prdidas. Repare y reemplace si fuese necesario.
Contrapresin excesiva en la El aire no pasa por el silenciador de purga. El silenciador de purga est sucio, reemplcelo.
torre de regeneracin (ms de
5 psig) Pasa demasiado aire por el silenciador de Revise la vlvula de entrada y las vlvulas de retencin
purga. El aire se filtra por la vlvula. de salida. Verifique que la vlvula de entrada est
cerrada en la torre de purga (torre de 0 psig).
Presin excesivamente alta en Calibracin incorrecta. Restablzcalo cuando la torre derecha est en lnea.
el indicador de purga de la torre
derecha.
12
10
0
0 10 20 30 40 50 60 70
22 35
20
30
18
16 25
14
12 20
10 15
8
6 10
4
5
2
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
45
55
40 50
35 45
30 40
35
25
30
20 25
15 20
15
10
10
5 5
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Configuracin del medidor de purga - psig Configuracin del medidor de purga - psig
65
80
60
55 70
50
45 60
40 50
35
30 40
25 30
20
15 20
10
10
5
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Configuracin del medidor de purga - psig Configuracin del medidor de purga - psig
110
180 220
200
160
Flujo de aire de purga - SCFM
Flujo de aire de purga - SCFM
180
140
160
120 140
100 120
80 100
80
60
60
40
40
20 20
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Configuracin del medidor de purga - psig Configuracin del medidor de purga - psig
330
Flujo de aire de purga - SCFM
240
300
210 270
180 240
210
150
180
120 150
90 120
60 90
60
30
30
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Configuracin del medidor de purga - psig
Configuracin del medidor de purga - psig
360 500
330 450
300
400
270
350
240
210 300
180 250
150 200
120 150
90
100
60
30 50
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Configuracin del medidor de purga - psig
Configuracin del medidor de purga - psig
400 600
350
500
300
400
250
200 300
150 200
100
100
50
0 0
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Configuracin del medidor de purga - psig Configuracin del medidor de purga - psig
900 900
Flujo de aire de purga - SCFM
800 800
Flujo de aire de purga - SCFM
700 700
600 600
500 500
400
400
300
300
200
200
100
100
0
0 10 20 30 40 50 60 70 0
0 10 20 30 40 50 60 70
Configuracin del medidor de purga - psig
Configuracin del medidor de purga - psig
10.19
CL OF AIR OUTLET
(4) .56'' DIA. MTG. HOLES
CL OF AIR OUTLET
DUST PARTICULATE
AFTERFILTER
TOWER PRESSURE ELECTRICAL ENCLOSURE PURGE ADJUSTMENT VALVE
GAUGE NEMA 4
CONTROLLER & DISPLAY PANEL
(SEE DETAIL) PURGE FLOW GAUGE 1/4'' MPT AUTOMATIC DRAIN
CONNECTION
BLUE MOISTURE
INDICATOR RELIEF VALVE
HIGH EFFICIENCY
PILOT AIR FILTER
PILOT AIR SHUT-OFF
CL OF AIR INLET 1'' FPT AIR INLET
VALVE CONNECTION
1/4'' MPT AUTOMATIC DRAIN HIGH EFFICIENCY
CONNECTION 56.56 PREFILTER
http://www.ingersollrandproducts.com
63.12 1/4'' MPT AUTOMATIC DRAIN
CONNECTION
40.50 11.00
10.19 17.38
32.50
19.81
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
5) DRYER TO BE LIFTED BY LIFTING SUPPORT ONLY.
DISPOSICIN GENERAL
HL90-HL120
580000-E
23
24
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF
2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING
4) LEFT/RIGHT TOWER REGEN LEFT TOWER DRYING LIGHT
5) DEW POINT (OPTIONAL)
FACE OF AIR INLET & OUTLET 6) REGEN SEQUENCE STATUS
(OPTIONAL 3-VALVE BYPASS) 8) COMPRESSOR INTERLOCK (OPTIONAL) DRYER OFF / ALARM LIGHT
9) AUTO RESTART
2.00 TYP RIGHT TOWER REGEN LIGHT
PUSH BUTTONS RIGHT TOWER DRYING LIGHT
1) ON
2.00 (TYP) 2) OFF
3) RESET
32.56 4) TEST
5) SET
CONTROLLER & DISPLAY PANEL DETAIL
6) SELECT DISPLAY
43.75 7) ENTER
8) +/-
28.00
32.00
11.19
CL OF AIR OUTLET
34.50 FACE OF AIR OUTLET
(4) .56'' DIA. MTG. HOLES 1 1/2'' FPT AIR OUTLET
10.25 CONNECTION
20.00 (HL 200)
19.00 (HL 160)
1 1/2'' FPT AIR INLET
DESICCANT FILL PORT CONNECTION
CL OF AIR OUTLET
ELECTRICAL
TOWER PRESSURE GAUGE ENCLOSURE PURGE ADJUSTMENT VALVE
NEMA 4
CONTROLLER & DISPLAY PANEL DUST PARTICULATE
(SEE DETAIL) PURGE FLOW GAUGE
AFTERFILTER
1/4'' MPT AUTOMATIC DRAIN
BLUE MOISTURE CONNECTION
INDICATOR
RELIEF VALVE
PILOT AIR FILTER
CL OF AIR INLET
1/4'' MPT AUTOMATIC DRAIN
CONNECTION
59.50
66.12 HIGH EFFICIENCY
PREFILTER
http://www.ingersollrandproducts.com
Secadora desecante serie HL, modelos 90-5000
DESICCANT DRAIN PORT
14.0 DISPOSICIN GENERAL
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSICIN GENERAL
HL160-HL200
580001-D
FACE OF AIR INLET & OUTLET LCD DISPLAY POWER ON LIGHT
(OPTIONAL 3-VALVE BYPASS) 1) DRYER ON/OFF
2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
2.00 TYP 5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
2.00 TYP
RIGHT TOWER REGEN LIGHT
PUSH BUTTONS RIGHT TOWER DRYING LIGHT
1) ON
44.19 @ HL 250 2) OFF
50.38 @ HL 300 3) RESET
4) TEST
5) SET CONTROLLER & DISPLAY PANEL DETAIL
28.00 32.00 6) SELECT DISPLAY
7) ENTER
8) +/-
10.69
CL OF AIR OUTLET
DUST PARTICULATE
AFTERFILTER
TOWER PRESSURE ELECTRICAL
GAUGE ENCLOSURE PURGE ADJUSTMENT VALVE
NEMA 4
CONTROLLER & DISPLAY PANEL PURGE FLOW GAUGE
(SEE DETAIL)
1/4'' MPT AUTOMATIC DRAIN
CONNECTION
BLUE MOISTURE
INDICATOR RELIEF VALVE
PILOT AIR FILTER
PILOT AIR SHUT-OFF
VALVE
1/4'' MPT AUTOMATIC DRAIN CL OF AIR INLET AIR INLET CONN.
CONNECTION 1 1/2'' FPT @ HL 250
2'' FPT @ HL 300
60.00
http://www.ingersollrandproducts.com
66.81
HIGH EFFICIENCY
PREFILTER
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSICIN GENERAL
HL250-HL300
580002-D
25
26
38.50
LCD DISPLAY
1) DRYER ON/OFF POWER ON LIGHT
FACE OF AIR INLET & OUTLET 2) DRYER ALARM LEFT TOWER REGEN LIGHT
(OPTIONAL 3-VALVE BYPASS) 3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
50.94 2.00 TYP
32.00
11.19
CL OF AIR OUTLET
BLUE MOISTURE
INDICATOR RELIEF VALVE
1/4'' MPT AUTOMATIC
PILOT AIR FILTER DRAIN CONNECTION
L
1/4'' MPT AUTOMATIC DRAIN CL OF AIR INLET 2'' FPT AIR INLET
CONNECTION CONNECTION
60.25
67.81
HIGH EFFICIENCY
PREFILTER
http://www.ingersollrandproducts.com
34.00
1/4'' MPT AUTOMATIC
DRAIN CONNECTION
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSICIN GENERAL
HL400
580003-D
40.50 LCD DISPLAY
1) DRYER ON/OFF POWER ON LIGHT
2) DRYER ALARM LEFT TOWER REGEN LIGHT
FACE OF AIR INLET & OUTLET 3) LEFT/RIGHT TOWER DRYING
(OPTIONAL 3-VALVE BYPASS) 4) LEFT/RIGHT TOWER REGEN LEFT TOWER DRYING LIGHT
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
2.00 TYP
RIGHT TOWER REGEN LIGHT
54.50 @ HL500 PUSH BUTTONS RIGHT TOWER DRYING LIGHT
57.25 @ HL600 1) ON
2.00 (TYP) 2) OFF
(4) O .56 MOUNTING HOLES
3) RESET
4) TEST
5) SET CONTROLLER & DISPLAY PANEL DETAIL
6) SELECT DISPLAY
7) ENTER
8) +/-
29.00 33.00
12.19
CL OF AIR OUTLET
FACE OF AIR OUTLET
11.50
27.50 @ HL 500
30.25 @ HL 600 2'' FPT AIR OUTLET
CONNECTION
CL OF AIR OUTLET
HIGH EFFICIENCY
PREFILTER
http://www.ingersollrandproducts.com
40.00 DRAIN CONNECTION
12.19 20.81
17.00
27.50 @ HL 500
56.50 30.25 @ HL 600 40.50
FACE OF AIR INLET CL OF AIR INLET
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSICIN GENERAL
HL500-HL600
580004-D
27
28
FACE OF AIR INLET & OUTLET
(OPTIONAL 3-VALVE BYPASS)
9.62 PURGE ADJUSTMENT VALVE
2.00 TYP
(4) .56''O MOUNTING HOLES 44.00 3.00 TYP FACE AIR OUTLET CL OF AIR OUTLET
CL AIR OUTLET
ELECTRICAL
ENCLOSURE
NEMA 4
http://www.ingersollrandproducts.com
HIGH EFFICIENCY
PREFILTER
50.50
1/4'' MPT AUTOMATIC
DESICCANT
DRAIN PORT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSICIN GENERAL
HL800-HL1200
580005-E
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF
2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
ELECTRICAL
ENCLOSURE CL OF AIR OUTLET
NEMA 4
RELIEF VALVE
TOWER PRESSURE
GAUGE
BLUE MOISTURE
INDICATOR
PURGE MUFFLER
PILOT AIR
SHUT-OFF 80.06 PILOT AIR FILTER
VALVE PURGE FLOW
GAUGE
56.88
CL OF AIR INLET
4'' FLANGE AIR
INLET CONNECTION
http://www.ingersollrandproducts.com
2'' NPT PLUG 24.25
DESICCANT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSICIN GENERAL
HL1500
580006-D
29
30
LCD DISPLAY
1) DRYER ON/OFF POWER ON LIGHT
2) DRYER ALARM
3) LEFT/RIGHT TOWER DRYING LEFT TOWER REGEN LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL) LEFT TOWER DRYING LIGHT
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
(4) .56''O MOUNTING HOLES 54.00 3.00 2.00 TYP 22.38 CL OF AIR OUTLET 4'' 150# R.F. FLANGE
TYP AIR OUTLET CONNECTION
OUTLET CHECK OUTLET CHECK
38.12 FACE OF OUTLET VALVE VALVE
CONTROLLER AND
2'' NPT PLUG DISPLAY PANEL
DESICCANT (SEE DETAIL)
FILL PORT
CL OF AIR OUTLET
ELECTRICAL
ENCLOSURE
NEMA 4
PURGE CHECK
VALVE
PURGE CHECK
VALVE
TOWER PRESSURE
GAUGE RELIEF
BLUE VALVE
MOISTURE
91.88 INDICATOR
PURGE FLOW
GAUGE PURGE
PURGE ADJUSTMENT
MUFFLER VALVE
67.25
http://www.ingersollrandproducts.com
FILTER
PILOT AIR
SHUT-OFF
DRAIN PORT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSICIN GENERAL
HL1800-HL2100
580029-D
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF LEFT TOWER REGEN LIGHT
2) DRYER ALARM LEFT TOWER DRYING LIGHT
3) LEFT/RIGHT TOWER DRYING
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
8) COMPRESSOR INTERLOCK (OPTIONAL)
9) AUTO RESTART DRYER OFF / ALARM LIGHT
60.75
RIGHT TOWER REGEN LIGHT
PUSH BUTTONS RIGHT TOWER DRYING LIGHT
43.00 47.00 1) ON
2) OFF
3) RESET
4) TEST
5) SET CONTROLLER & DISPLAY PANEL DETAIL
6) SELECT DISPLAY
7) ENTER
8) +/-
2.00 (TYP)
(4) .56''O MOUNTING HOLES
3.00 (TYP)
54.00
38.25 FACE OF OUTLET 22.38 CL OF AIR OUTLET 4'' FLANGE AIR
OUTLET CONNECTION
2'' NPT PLUG
DESICCANT
FILL PORT
91.88
PURGE
ELECTRICAL ADJUSTMENT
ENCLOSURE VALVE
TOWER PRESSURE NEMA 4
GAUGE RELIEF VALVE
BLUE
MOISTURE
INDICATOR PURGE FLOW
GAUGE
PURGE
MUFFLER
PILOT AIR
FILTER
67.25
http://www.ingersollrandproducts.com
CL OF AIR INLET
PILOT AIR
2'' NPT PLUG SHUT-OFF 26.12
DESICCANT VALVE
DRAIN PORT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
DISPOSICIN GENERAL
HL2700
580007-D
31
32
5.88
60.00
(4) .56''O MOUNTING HOLES 1.50 (TYP) PILOT AIR FILTER
63.00
CLOF OUTLET
66.00
6'' RAISED FLANGE 150#
41.38 FACE OF OUTLET AIR OUTLET CONNECTION
23.00
CHECK VALVE
DESICCANT
FILL PORT
CL OF AIR OUTLET
100.00
PURGE FLOW
BLUE MOISTURE GAUGE
INDICATOR CL OF AIR INLET
6'' FLUSH FLANGE 125#
72.25 AIR INLET CONNECTION
http://www.ingersollrandproducts.com
PURGE VALVE
FLOW VALVE
PURGE MUFFLER
DESICCANT
DRAIN PORT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
5) FILTER PACKAGES SHIPPED SEPARATELY.
FILTER PIPING SUPPORT, IF REQUIRED, TO BE
SUPPLIED BY CUSTOMER.
DISPOSICIN GENERAL
HL3300-HL4000
580092-E
12.00
LCD DISPLAY POWER ON LIGHT
1) DRYER ON/OFF
CL OF MOUNTING HOLE 2) DRYER ALARM LEFT TOWER REGEN LIGHT
3) LEFT/RIGHT TOWER DRYING LEFT TOWER DRYING LIGHT
4) LEFT/RIGHT TOWER REGEN
5) DEW POINT (OPTIONAL)
6) REGEN SEQUENCE STATUS
7) COMPRESSOR INTERLOCK
8) AUTO RESTART DRYER OFF / ALARM LIGHT
32.50
6.00 (TYP)
CL OF MOUNTING HOLE
PILOT AIR FILTER
60.00
(4) O .62 MOUNTING HOLES 1.50 (TYP)
63.00
ELECTRICAL
CONTROLLER AND ENCLOSURE CL OF AIR OUTLET
DISPLAY PANEL NEMA 4
(SEE DETAIL)
TOWER PRESSURE
GAUGE PURGE ADJUSTMENT
VALVE
TOWER RELIEF
VALVE
http://www.ingersollrandproducts.com
AIR INLET CONNECTION
CL OF AIR INLET
64.00
FLOW VALVE
14.0 DISPOSICIN GENERAL
34.75
PURGE MUFFLER
DESICCANT DRAIN PORT
*NOTES:
1) MAXIMUM WORKING PRESSURE - 150 P.S.I.
2) SAFETY RELIEF VALVE SETTING - 165 P.S.I
3) PILOT AIR LINE NOT SHOWN FOR CLARITY.
4) ALL WIRING IS IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE'S LATEST EDITION.
5) FILTER PACKAGES SHIPPED SEPARATELY.
FILTER PIPING SUPPORT, IF REQUIRED, TO BE
SUPPLIED BY CUSTOMER.
DISPOSICIN GENERAL
HL5000
580306-B
33
15.0 DIAGRAMA DE CABLEADO
DIAGRAMA DE CABLEADO
HL90-HL5000
TM-580078-C
DIAGRAMA DE FLUJO
HL90-HL2700
580022-E
DIAGRAMA DE FLUJO
HL3300-HL5000
580213-C
CANT./
DESCRIPCIN HL901H00AA HL1201H00AA HL1601H00AA HL2001H00AA HL2501H00AA REPUESTOS
UNIDAD
1 2 3
VLVULA, BOLA, AIRE DE CONTROL, 1/4" 38054086 38054086 38054086 38054086 38054086 1
Repuesto. Las cantidades bajo este encabezado reflejan el nmero de cada artculo que recomendamos mantenga a mano para mantenimiento o reparacin.
La cantidad apropiada para su aplicacin depender de cun graves sean las interrupciones de servicio para su operacin.
Clase Cantidad Recomendado para
1 Mnima Servicio domstico cuando se acepten interrupciones en el servicio.
2 Promedio Servicio domstico cuando se acepten algunas interrupciones en el servicio.
3 Mxima Servicio de exportacin o domstico cuando no se acepten interrupciones en el servicio.
Repuesto. Las cantidades bajo este encabezado reflejan el nmero de cada artculo que recomendamos mantenga a mano para mantenimiento o reparacin.
La cantidad apropiada para su aplicacin depender de cun graves sean las interrupciones de servicio para su operacin.
Clase Cantidad Recomendado para
1 Mnima Servicio domstico cuando se acepten interrupciones en el servicio.
2 Promedio Servicio domstico cuando se acepten algunas interrupciones en el servicio.
3 Mxima Servicio de exportacin o domstico cuando no se acepten interrupciones en el servicio.
MANMETRO, PRESIN DE
38052973 38052973 38052973 38052973 38052973 3
PURGA/TORRE 3 1/2"
Repuesto. Las cantidades bajo este encabezado reflejan el nmero de cada artculo que recomendamos mantenga a mano para mantenimiento o reparacin.
La cantidad apropiada para su aplicacin depender de cun graves sean las interrupciones de servicio para su operacin.
Clase Cantidad Recomendado para
1 Mnima Servicio domstico cuando se acepten interrupciones en el servicio.
2 Promedio Servicio domstico cuando se acepten algunas interrupciones en el servicio.
3 Mxima Servicio de exportacin o domstico cuando no se acepten interrupciones en el servicio.
Repuesto. Las cantidades bajo este encabezado reflejan el nmero de cada artculo que recomendamos mantenga a mano para mantenimiento o reparacin.
La cantidad apropiada para su aplicacin depender de cun graves sean las interrupciones de servicio para su operacin.
Clase Cantidad Recomendado para
1 Mnima Servicio domstico cuando se acepten interrupciones en el servicio.
2 Promedio Servicio domstico cuando se acepten algunas interrupciones en el servicio.
3 Mxima Servicio de exportacin o domstico cuando no se acepten interrupciones en el servicio.
DESCRIPCIN CCN
TRANSMISOR, PUNTO DE
38053047
CONDENSACIN -40 F
TRANSMISOR, PUNTO DE
38053062
CONDENSACIN -100 F
DESCRIPCIN DE LA VLVULA VLVULA VLVULA SLO VLVULA KIT DE ACTUADOR KIT DEL MOTOR
W / ACT REPARACIN
VLVULA, MARIPOSA 3 "W / ACTUADOR 38053393 23126865 23126923 23126980 23127053
Flujo de Flujo de
Desecante
entrada entrada Flujo Conexin
Profundidad Profundidad Peso de Peso por
Punto de Punto de de Ancho pulg. Altura pulg. de entrada
MODELO pulg. sin pasar pulg. con pasar embarque lb secadora lb
condensa condensaci purga (cm) (cm) y salida de
por alto (cm) por alto (cm) (kg) (kg)
cin de - n de -100 SCFM aire
40 SCFM SCFM
HL90 90 72 14 40.5 (102.9) 30 (76.2) 37.5 (95.3) 63 12 (160.3) 1 475 (213) 100 (45)
HL120 120 96 19 40.5 (102.9) 30 (76.2) 37.5 (95.3) 63 12 (160.3) 1 563 (255) 134 (61)
HL160 160 128 26 44.5 (113) 32 (81.3) 43.75 (111.1) 66.12 (167.9) 1 1/2 707 (321) 192 (87)
HL200 200 160 30 44.5 (113) 32 (81.3) 43.75 (111.1) 66.12 (167.9) 1 1/2 731 (332) 236 (107)
HL250 250 200 40 48.5 (123.2) 32 (81.3) 44.19 (112.2) 66.81 (169.7) 1 1/2 869 (394) 290 (132)
HL300 300 240 48 48.5 (123.2) 32 (81.3) 50.38 (128.0) 66.81 (169.7) 2 924 (419) 344 (156)
HL400 400 320 65 52.5 (133.4) 36.19 (91.9) 50.94 (129.4) 67.81 (172.2) 2 1115 (506) 470 (213)
HL500 500 400 81 56.5 (143.5) 39.69 (100.8) 54.5 (138.4) 82.5 (209.6) 2 1564 (709) 638 (289)
HL600 600 480 93 56.5 (143.5) 42.4 (107.8) 57.25 (145.4) 82.5 (209.6) 2 1664 (755) 748 (339)
HL800 800 640 130 64 (162.6) 51.25 (130.2) 64.38 (163.5) 87.62 (222.6) 3 2017 (915) 900 (408)
HL1000 1000 800 162 64 (162.6) 51.25 (130.2) 64.38 (163.5) 87.62 (222.6) 3 2237 (1015) 1100 (499)
HL1200 1200 960 195 64 (162.6) 51.25 (130.2) 64.38 (163.5) 87.62 (222.6) 3 2424 (1100) 1270 (576)
HL1500 1500 1200 243 78 (198.1) 54.76 (139.1) N/A 80 (203.2) 4 2974 (1349) 1600 (726)
HL1800 1800 1440 292 84 (213.4) 60.62 (154.0) N/A 91.88 (233.4) 4 3905 (1771) 2000 (907)
HL2100 2100 1680 340 84 (213.4) 60.62 (154.0) N/A 91.88 (233.4) 4 4279 (1941) 2340 (1062)
HL2700 2700 2160 438 84 (213.4) 60.76 (154.3) N/A 91.88 (233.4) 4 4926 (2234) 2928 (1328)
HL3300 3300 2640 535 96 (244) 66 (167.6) N/A 100 (254) 6 2950 (1338) 3800 (1723) *
HL4000 4000 3200 649 96 (244) 66 (167.6) N/A 100 (254) 6 3000 (1361) 4226 (1917) *
HL5000 5000 4000 811 102 (259) 72 (183) N/A 92 (233.7) 6 3950 (1792) 5138 (2330) *
* Secador de peso que indica no incluye un desecante. Desecante enviar por separado
Nota: Todas las secadoras mencionadas cuentan con rgimen de 150 psig y 120 F de temperatura mxima de entrada.
La capacidad y el flujo de purga se basan en condiciones de entrada estndar (100 psig y 100 F) y variarn en
AVISO
La informacin sobre especificaciones anterior es precisa al momento de la publicacin.
Consulte la etiqueta de la serie del equipo para obtener las especificaciones reales para las
unidades.