Академический Документы
Профессиональный Документы
Культура Документы
Bulletin 00A03B02-01E
www.yokogawa.com
Field Instruments
Pressure Transmitters
DPharp EJX Series Differential Pressure DPharp EJA-E Series Differential Pressure
and Pressure Transmitters and Pressure Transmitters
Liq Liq
Gas Gas
Stm Stm
Ultra-high performance, the flag-ship model of DPharp. A best-selling pressure transmitter series featuring silicon reso-
High accuracy and fast response. nant sensor.
Unique features include; Fast response, corresponding to various applications.
Multi-sensing (Differential pressure and Static pressure). Excellent long term stability slashes maintenance cost.
Output signal characterizer. Unique features include;
Multi-functional indicator with local parameter setting function Multi-sensing (Differential pressure and Static pressure).
(optional). Output signal characterizer.
Alarm output for measured pressure and static pressure Multi-functional indicator with local parameter setting function
(optional). (optional).
High reliability. SIL2 capable.
SIL2 certified by TV. 1 to 5 V low power output type available.
Infrastructure for field wireless network. Make wired HART and Modbus trans- Identical accuracy and stability as wired trans-
Manage up to 20 Field Wireless mitter wireless (FN310). mitters.
Access Points and 500 wireless devic- Make analog input, digital input/output, Battery operation. More than 10 years battery
es (YFGW410). pulse input count wireless. life.
Available in single and redundant op- Battery operation. Publish period of 1 second to 1 hour. EJX sup-
eration. Publish period of 5 seconds to 1 hour port 0.5 seconds publish period.
Redundant switch over in less than 1 (FN310) and 1 second to 1 hour (FN510). Support 13 meters (MAX) antenna extension
second. Supply power to a wired transmitter cable.
Highly reliable redundant communica- (FN310). Act as a repeater and a sensor.
tion: DUOCAST. Support 20 meters (MAX) FN110 ex-
Support 13 meters (MAX) antenna ex- tension cable.
tension cable (YFGW510). (*) The above pictures show with FN110 Field
Wireless Communication Module attached.
Gas Analyzers
Gas Chromatograph Oxygen Analyzers
GC8000 ZR402/ZR202 AV550G
Process Gas Chromatograph Zirconia Oxygen Analyzers Averaging Converter
ZR402G Capable of accepting in-
puts from up to 8 oxygen
detectors and 8 individ-
ual outputs are available
ZR22G/S Averaging of multiple
point oxygen measure-
ments is ideally suited for combustion control
ZR202G/S
Measurement with probe directly inserted
into furnace or boiler OX400
Touch Panel
Integrated and separate types available Low Concentration Zirconia Oxygen Analyzer
Also can be used as a high temperature hu- Capable of measuring
midity analyzer a wide range of con-
Fully field-repairable probe centrations, from 0-10
ppm up to 0-100 vol%
HART communication
O2.
Explosionproof (FM, CSA, ATEX) (ZR22S,
Oxygen concentration
ZR202S)
control in semiconductor-related diffusion
and drying furnaces and in LCD manufactur-
MG8G/MG8E ing processes
Paramagnetic Oxygen Analyzers
OX100/OX102
Fast analysis with Max. 3 ovens. Limiting Current Type Oxygen Analyzers
Parallel GC by GC Module concept.
Ideally suited for measuring
The large 12.1 inch color LCD touch screen. oxygen concentrations of
Ideally suited for measuring oxygen concen- N2 purged flow-sol-
trations of flammable gases dering machine,
MG8E has flameproof construction etc.
Simultaneously mea-
sures NOx, SO2, CO,
CO2 and O2 with sam-
pling system
IR100 IR200 IR400
Measuring Components
IR100: CO2, CO, CH4 IR200: CO2, CO, CH4, IR400: NO, SO2, CO2,
SO2, NO, O2 CO, CH4, O2
Field Instruments Liquid Analyzers
Flowmeters Level Transmitters pH/ORP Analyzers Conductivity Analyzers
ADMAG AXF ADMAG AXW ADMAG AXR ADMAG CA EJA118E/EJX118A Differential PH450G FLXA21 PH71/PH72 pH/ORP Sensors SC450G DC402G FLXA21 ISC450G FLXA21 ISC40G/S SC72
EJA210E/EJX210A Conductivity
Magnetic Flowmeter Magnetic Flowmeter 2-wire Magnetic Flowmeter Capacitance Magnetic Flowmeter Pressure Transmitters 4-Wire pH/ORP 2-Wire pH/ORP Personal pH, for 4-Wire Conductivity/ Dual Cell Conductivity/ 2-Wire Conductivity 4-Wire Inductive 2-Wire Inductive Inductive Personal
Level Transmitter Sensors
with Diaphragm Seals Converter Transmitter pH/ORP Meters Process Use Resistivity Converter Resistivity Converter Transmitter Conductivity Converter Conductivity Transmitter Conductivity Sensors Conductivity Meter
Liq Liq Liq Liq SC4A-AD-09
Liq Liq
SC4A-AD-15
"Dual Frequency Excitation Method" real- AXW is ideal for industrial process lines, An extra AC power supply is not neces- Non-wetted electrode ensures stable flow
izes the stable measurement of high con- and water supply / sewage applications. sary. 2-wire loop powered performance measurement with ultra-low conductivity Large, high-resolution 12 languages. Waterproof (IP67) con- PH8EFP/ Large, high-resolution Differential, ratio or cal- 12 languages. Large, high-resolution 12 languages. Measuring range: 100 Intelligent, portable
centration slurry fluid and low conductivi- allows direct connection to DCS I/O card fluids up to 0.01 S/cm. graphical display and struction allows mea- PH8ERP graphical display and culated outputs graphical display and SC4A-SB S/cm 1999 mS/cm conductivity meter with
With outstanding reliability and ease of Touch screen display. Touch screen display. Touch screen display.
ty fluid. possible, thus drastically reducing the ini- touchscreen operation surement in wet envi- FU20 touchscreen operation Universal touchscreen operation with a single sensor waterproof (IP67) con-
operation, developed on decades of CA utilizes pure alumina ceramic (99.9%) Two sensors can be Two sensors can be
tial cost and power consumption. for ease of use ronment for ease of use conductivity/resistivity, for ease of use Material: PEEK or Tef- struction
User-friendly functions; such as an elec- field-proven experience, the AXW will in- in the flowtube for unsurpassed corrosion connected. connected.
trode adhesion level diagnosis function, crease user benefits while reducing total AXR has SIL2 Safety Integrity Level (IEC and abrasion resistance. Diagnostic functions Various convenient Diagnostic functions software switchable Diagnostic functions lon (PFA) Various convenient
for minimum mainte- functions: 300-point for minimum mainte- for minimum mainte- SC210G functions: 300-point
infra-red switches which can be used for cost of ownership. 61508) certified. AXR is capable of SIL2 Matrix temperature
setting parameters without opening the single use and SIL3 redundant use, as nance data memory, alarm nance compensation for pure nance data memory, alarm
case cover. standard. Temperature compen- clock, etc. * Temperature com- water applications * Temperature com- Appropriate sensor for clock, etc.
Flange-mounting, compact differential Ideal for measuring the levels and densi-
sation and predefined pensation, predefined pensation and pre- your application
pressure transmitter. ties of corrosive and high-temperature Easy to use EXA con-
pH buffer tables for OIML buffer tables, defined OIML buffer ta-
fluids. trol panel
Direct mounting to a tank. best accuracy cell fouling monitoring bles for best accura-
digitalYEWFLO EJA/EJX Series Differential EJX910A Small flange size model also available. Appropriate sensor for for best accuracy USP<645> monitoring cy.
Small flange size model also available. 8 languages
Digital Vortex Flowmeter Pressure Transmitters Multivariable Transmitter your application 8 languages
Liq Liq Liq Control Elements and Converters Turbidity Analyzers Chlorine Analyzers Dissolved Oxygen Analyzers
Gas Gas Gas
Stm Stm Stm YVP110 PK200 Current-to-Pneumatic TB750G TB400G FC400G FC500G RC400G DO402G FLXA21 DO70G/DO30G
Multi-variable Reduced Valve Positioner Converter Right Angle Scattered Scattered-Light Free Available Chlorine Free Available Chlorine Residual Chlorine 4-Wire Dissolved 2-Wire Dissolved Dissolved Oxygen
type bore type
Light Turbidity Analyzer Turbidity Analyzer Analyzer Analyzer Analyzer Oxygen Converter Oxygen Transmitter Sensors
Spectral signal processing automatically Built-in temperature sensor within the Combined with an orifice, measures Fully compensated mass flow: all flow
optimizes the settings at all times, from shedder bar offers the mass flow output or liquid, gas, and steam flow rates. factors can be automatically and dynami-
immediately after power-on. the temperature output. cally calculated to an optimal value.
Available for direct mounting without
Self-diagnostics, one step ahead of other No installation of the temperature device three-valve manifold. 1.0% mass flow rate accuracy over 1:10
flowmeters, enables predictive mainte- is needed for the process. flow range.
Outstanding long-term stability slashes DO70G
nance.
Durable meter design mostly meets the maintenance costs. Simultaneous dual output of 4 to 20 mA
Simultaneous analog and pulse signal steam flow such as water hammer, high and pulse signals for total flow, flow rate, Improvement of manipulation perfor- Electronic feedback system achieving
outputs. temperature process, etc. or alarm status. mance. high reliability and high performance. DO30G
Auto tuning, tight shutoff, full open etc.
Energy-saving design achieve economy. Non-reagent Type Non-reagent Type 12 languages. Measurement object: Measurement
High-temperature and cryogenic models Reduced bore type measures lower flow-
Enhancement of diagnosis functions. Polarographic method using rotating Polarographic method using rotating Long-term stable sensor Touch screen display. of dissolved oxygen in aeration
also available. rate. Designed to be replacement-compatible
Diagnosis functions: self check, sensor gold electrode gold electrode tanks at sewage treatment plants.
with the former model 5502. User configurable measuring range Surface scattered light method using Reagent Type
Display unit in mg/l, ppm, or % sat- Two sensors can be connected.
US300FM Ultrasonic US300PM Portable ROTAMETER ROTAMASS failure etc. Measuring range:
Ideal for measurement of free avail- Ideal for measurement of free avail- uration
Historian data: cycle count, total travel etc. Easy to operate..one side access. from 0-0.2 NTU to 0-100 NTU. kaolin, formazin, or PSL Polarographic method using rotating 0 to 25mg/l (ppm) (DO70G),
Flowmeter Ultrasonic Flowmeter Variable Area Flowmeter Coriolis Mass Flowmeter Highly reliable measurement with (polystyrene latex) for calibration
able chlorine in water supply and able chlorine in water supply and
platinum electrode
Temperature compensation, salt 0 to 20mg/l (ppm) (DO30G)
distribution systems distribution systems concentration compensation and
excellent linearity and repeatability. Highly reliable measurement at wa- Ideal for measurement of residual Type of sensor:
Field-configurable from 0-1 to 0-3 Measuring range selectable: barometric air pressure compensa-
ter supply and sewage systems
Liq Liq Liq FieldMate In-line connection available mg/l for two switchable output rang- 0-1/0-2/0-3 mg/l switchable or chlorine in chlorination processes of tion for best accuracy Optical DO sensor (DO70G),
Gas Versatile Device Management Wizard BT200 BRAIN Terminal Easy-to-clean cell Measuring range: 0-2 to 0-2000 mg/l es 0-5/0-10 mg/l switchable water supply systems and in cooling Galvanic cell DO sensor (DO30G)
Ideal for measurement of dissolved
(or degrees, unit selectable) water of thermal power stations
Micro processor-based, intelligent oxygen in aeration tanks at sewage
converter Measuring range: 0 to 10mg/l treatment plants, etc.
SC4A-AD-15
"Dual Frequency Excitation Method" real- AXW is ideal for industrial process lines, An extra AC power supply is not neces- Non-wetted electrode ensures stable flow
izes the stable measurement of high con- and water supply / sewage applications. sary. 2-wire loop powered performance measurement with ultra-low conductivity Large, high-resolution 12 languages. Waterproof (IP67) con- PH8EFP/ Large, high-resolution Differential, ratio or cal- 12 languages. Large, high-resolution 12 languages. Measuring range: 100 Intelligent, portable
centration slurry fluid and low conductivi- allows direct connection to DCS I/O card fluids up to 0.01 S/cm. graphical display and struction allows mea- PH8ERP graphical display and culated outputs graphical display and SC4A-SB S/cm 1999 mS/cm conductivity meter with
With outstanding reliability and ease of Touch screen display. Touch screen display. Touch screen display.
ty fluid. possible, thus drastically reducing the ini- touchscreen operation surement in wet envi- FU20 touchscreen operation Universal touchscreen operation with a single sensor waterproof (IP67) con-
operation, developed on decades of CA utilizes pure alumina ceramic (99.9%) Two sensors can be Two sensors can be
tial cost and power consumption. for ease of use ronment for ease of use conductivity/resistivity, for ease of use Material: PEEK or Tef- struction
User-friendly functions; such as an elec- field-proven experience, the AXW will in- in the flowtube for unsurpassed corrosion connected. connected.
trode adhesion level diagnosis function, crease user benefits while reducing total AXR has SIL2 Safety Integrity Level (IEC and abrasion resistance. Diagnostic functions Various convenient Diagnostic functions software switchable Diagnostic functions lon (PFA) Various convenient
for minimum mainte- functions: 300-point for minimum mainte- for minimum mainte- SC210G functions: 300-point
infra-red switches which can be used for cost of ownership. 61508) certified. AXR is capable of SIL2 Matrix temperature
setting parameters without opening the single use and SIL3 redundant use, as nance data memory, alarm nance compensation for pure nance data memory, alarm
case cover. standard. Temperature compen- clock, etc. * Temperature com- water applications * Temperature com- Appropriate sensor for clock, etc.
Flange-mounting, compact differential Ideal for measuring the levels and densi-
sation and predefined pensation, predefined pensation and pre- your application
pressure transmitter. ties of corrosive and high-temperature Easy to use EXA con-
pH buffer tables for OIML buffer tables, defined OIML buffer ta-
fluids. trol panel
Direct mounting to a tank. best accuracy cell fouling monitoring bles for best accura-
digitalYEWFLO EJA/EJX Series Differential EJX910A Small flange size model also available. Appropriate sensor for for best accuracy USP<645> monitoring cy.
Small flange size model also available. 8 languages
Digital Vortex Flowmeter Pressure Transmitters Multivariable Transmitter your application 8 languages
Liq Liq Liq Control Elements and Converters Turbidity Analyzers Chlorine Analyzers Dissolved Oxygen Analyzers
Gas Gas Gas
Stm Stm Stm YVP110 PK200 Current-to-Pneumatic TB750G TB400G FC400G FC500G RC400G DO402G FLXA21 DO70G/DO30G
Multi-variable Reduced Valve Positioner Converter Right Angle Scattered Scattered-Light Free Available Chlorine Free Available Chlorine Residual Chlorine 4-Wire Dissolved 2-Wire Dissolved Dissolved Oxygen
type bore type
Light Turbidity Analyzer Turbidity Analyzer Analyzer Analyzer Analyzer Oxygen Converter Oxygen Transmitter Sensors
Spectral signal processing automatically Built-in temperature sensor within the Combined with an orifice, measures Fully compensated mass flow: all flow
optimizes the settings at all times, from shedder bar offers the mass flow output or liquid, gas, and steam flow rates. factors can be automatically and dynami-
immediately after power-on. the temperature output. cally calculated to an optimal value.
Available for direct mounting without
Self-diagnostics, one step ahead of other No installation of the temperature device three-valve manifold. 1.0% mass flow rate accuracy over 1:10
flowmeters, enables predictive mainte- is needed for the process. flow range.
Outstanding long-term stability slashes DO70G
nance.
Durable meter design mostly meets the maintenance costs. Simultaneous dual output of 4 to 20 mA
Simultaneous analog and pulse signal steam flow such as water hammer, high and pulse signals for total flow, flow rate, Improvement of manipulation perfor- Electronic feedback system achieving
outputs. temperature process, etc. or alarm status. mance. high reliability and high performance. DO30G
Auto tuning, tight shutoff, full open etc.
Energy-saving design achieve economy. Non-reagent Type Non-reagent Type 12 languages. Measurement object: Measurement
High-temperature and cryogenic models Reduced bore type measures lower flow-
Enhancement of diagnosis functions. Polarographic method using rotating Polarographic method using rotating Long-term stable sensor Touch screen display. of dissolved oxygen in aeration
also available. rate. Designed to be replacement-compatible
Diagnosis functions: self check, sensor gold electrode gold electrode tanks at sewage treatment plants.
with the former model 5502. User configurable measuring range Surface scattered light method using Reagent Type
Display unit in mg/l, ppm, or % sat- Two sensors can be connected.
US300FM Ultrasonic US300PM Portable ROTAMETER ROTAMASS failure etc. Measuring range:
Ideal for measurement of free avail- Ideal for measurement of free avail- uration
Historian data: cycle count, total travel etc. Easy to operate..one side access. from 0-0.2 NTU to 0-100 NTU. kaolin, formazin, or PSL Polarographic method using rotating 0 to 25mg/l (ppm) (DO70G),
Flowmeter Ultrasonic Flowmeter Variable Area Flowmeter Coriolis Mass Flowmeter Highly reliable measurement with (polystyrene latex) for calibration
able chlorine in water supply and able chlorine in water supply and
platinum electrode
Temperature compensation, salt 0 to 20mg/l (ppm) (DO30G)
distribution systems distribution systems concentration compensation and
excellent linearity and repeatability. Highly reliable measurement at wa- Ideal for measurement of residual Type of sensor:
Field-configurable from 0-1 to 0-3 Measuring range selectable: barometric air pressure compensa-
ter supply and sewage systems
Liq Liq Liq FieldMate In-line connection available mg/l for two switchable output rang- 0-1/0-2/0-3 mg/l switchable or chlorine in chlorination processes of tion for best accuracy Optical DO sensor (DO70G),
Gas Versatile Device Management Wizard BT200 BRAIN Terminal Easy-to-clean cell Measuring range: 0-2 to 0-2000 mg/l es 0-5/0-10 mg/l switchable water supply systems and in cooling Galvanic cell DO sensor (DO30G)
Ideal for measurement of dissolved
(or degrees, unit selectable) water of thermal power stations
Micro processor-based, intelligent oxygen in aeration tanks at sewage
converter Measuring range: 0 to 10mg/l treatment plants, etc.