Вы находитесь на странице: 1из 7
ANTI-FIRE CO.,LTD. . ‘Training Manval for Sequential Detection _ arnstdeeuutnfedatusin avin ALARM ————— TiSUsins sw RESET LED ABORT SILENCE Tamm | Suaaumaliend | a | A | dgans | nevada ells nafnd SILENCE ae —— detector vals! Toma pi naatinE SLENCE | wun | mmryaeuinguminteindstoehitel 2. nawiad ABORT LED ABORT nent 1. a \ deuengmgnaral fin nnsnf ABORT 1Judlnitos usevite aft Tansfad swa lium Disable 3 anit ews Trouble Ranie| wnqnaanl 2, fluvial! denleangiiqnnetl | “9 ver nadfind ABORT iaRintion obits tv 2 undmlsine whileonsinttuiiutiiourcunaliontos anus PIEZO Farida | _nadind SILENCE gare | araaeuynnensaziafusnsusenradousn Seynyroaien Peusorsh | qedrtsleunmutlalAiRaviagifentete melugite teu | dowd diunqyreua GaMingReser | PIEZOMD | VmUnReFeuuvde RESET mevremnnsrsans sea LED \ wihilmiia @ | Aninnila MANUAL RELEASE Glomuinqiniisloaiuaedesmssintistnatiil CO ‘Winaija ABORT SWITCH Wfongelfbiifinaremaldanmadiuuntedauae TY | euueentinndtaniuvanrtol 0-60 nf wfeernansinnsnas ABORT) ANTI-FI 1 IRE CO,LTD. Training Manual for Sequential Detection mavhowumem ( Operation of System) mavheruseuudinluail (Automatic Operation) Zimainenuitall 1. fomuazcuutily Sequehtial Detection (Flowchart No. 2) % wlogunsninzassi (Smoke, Heat, Flame vite Detector duq taiunlWiuesun) dav tao wide paunuacedagannae Alain unvdsdicyeyraurialiinesis (Alarm Bell) a S oqunsninzoedusaszeuusinen 2 sa seviviistesnouqadnganras Pre-Discharge useae as Seyqyrnwii eau (Alarm Hom) AhunFenudesaynyrnuntindtutla (Dry Contact) ldogunentsia viathuy ieddonyanrninern edu ssuulivernn, sevunyutewerna unsduy dud dol snuAunfuntesauquilscuumiwm aetuiuiermudlatmunlilunrsdsrevu (0, 15,30, 60 sec.) do Ser ae eee %S dotosnauguriamsduvasrsunrumuriinun wfesmuquaedsdeyryrlildvelnsalaaunnar Ganrdaviae vterinnralsioushaduinds viedsdiyqyraslldslstueudtaiteli Deluge Vato vous ( Trew Water Spray) woudediyeyanuldagunenftvinaevdu (Strobe Light) Hamu awk sunmaeaesreuurililsinursmuundovtesh suntan Witeufieneumtonmumentidugan — fsunmdudntanyamadstignnallseenanl paunumadlendavadotelnauautnateliiesmunieiadmundsgnideusennnls 2.78 ito 1. FiuduFouyanredodiyey mululedsqunenfaruqanandnaisatads wdelaiueusartuuudonr Beate = 4 ee enka ‘Tnunmastnd Abor wéevrnitunidnminasing Abor wtosnmuneretustuvie oaliinngs winds geanincst grease ac gie Heda nit La ee Soy ndhldglnaniehauqunradanstavaitoielstunudandaiul ddungiunindentdvitads Harldiunaienaesein Abort uuimiosmuny 2, Sidiuduitenganredetynyreutuleceunsataoutinednrndttadcununres Waamaluneindanian aneviney wansa ( nnsHnarsuunas (Disable Release Switch) sidavaumsunian (Disable) sei Witernquanlal snenmndediqyyraulaioquinantnouqunradandinfevtelsiuandadalé uidrfesns bistns maunpieransndudeyyruludogunsnlensiaala iustaneinduninnardnareundsnnduys ON Wie Enable vip ARM juaeuu Manual dinasinewudd namineueesreuu Manual seiludnmus Ao ladamiineusessuudatulatisinrieusaseuinanl Detector) azvinvuvtelahinewunn Wedewnansenaamtunaeiul Whianrenmy Manual Release Untosmaunuacdidiyay ouluifiqinrninununedlnndtatatevtelstuentarda iteltodadlaiiul uanreds Aeyryrnutensrosvanysalld fedtadumdvesatndunddinnstnanatundsarfluanny ON, Enable vie ARM hd uavlunasnduaiudosnuquasdediysyrnihivegunendatameunesu (Alarm Hom) uavlinasvtu (Strobe Light) tae wanna, Iunaeiiadsqunsaliaty (Optional) AUTO-MANUAL MODE SWITCH Wlerissrunit Auto Mode seuuseinnumalnl sraldneounicssudalaluarreuy Manuel wnitorercunh Manual Mode ssuusinbualtasrinwnuldnraand unvdunrededinyaymalneesreduntsscisninay 92 sinsauldiieiilatinaann Manual Release vitis Paget of7 ANTLFIRE CO.,LTD. ‘Training Manual for Sequential Detection FLOWCHART DIAGRAM 2 FOR FIRE SUPPRESSION SYSTEM SEQUENTIAL DETECTION CONCEPT Activate one dooctor Manual Reloass sulnenieraedinine 1 Ha uakaldawmrsivinde First Alam Stato aaa eas sane Alam aiyqyruneetits a . Activate 2 detector ‘Alarm Ball Of Alarm Hor Sound aulmeninsreduvieny 2 i aaynnaunsedenyn Rayne Hom Ha ‘Second Alarm State fataunsrna: Pre Discharged Shutdown AVC & Ventilation System sefauanativnanruninme [| Time Delay Adjustable wniosrmdamatuinialiulal (0,18, 20,60 see) ‘Strobe Light Operated [| aiyayrntvinsentanine Disable Released Switch Pnioninmsta sneiunts Disable Disable Release [Agent Release necaitunds ‘To protect area within 10 second for HFC-227ea{ FE-227,FM-200 } , NAF-SIll 60 second for Carbon Dioxide CO, System Discharge Continued for Water Spray System Page 2of7 ANTLFIRE CO.,LTD. Trlning Manual for Sequential Detection 2. faq Iilaas SHP Pro spraunps SHP Prd upalssudin donnuneminldldifh Conventional Fire Alarm ust Suppression Releasing Panel WA qnnnunal SHP Pro gnnenuuudrafulitfu Clean Agent Suppression, CO,,, Sprinkler (Pre action/Deluge) Suppression qonouquindnssalseneudougunenliinneeting doufussuunsas4uuazrouquavuudsavaantunas shiluWieqw unsdiitqunsnliet optional Module dudniseus Plug uu asuuaesovarndin Snckesng nema =F ——> See TO —h = ay _——* & = 5— a = Sinumewalues SHP Pro © rounsdalatnsineatinat © Anfiaihdenntnthiatinssniomuntanlqario Pt © ranma Solenoid tureu Sprinkler vie ARMAII Lure Suppression © Sinamusmsanruryesrenatla LED 10 seus © FILED Seven Segment drufimensnusehey vosntesihlengiy © sunmifusananinansnsrsuulanrian Dip Switch © SPIEZO dhufutuienfeunalyyrnauny © fiwind Reset dauiurdedreuy © Aefindiaudungnifoaieuuas Alarm ( Silence Switch) ©) SefindduFuundinase? Release © ynsnestnaslairaunn 24 VOC, 4.0 Amps © srunanidentifiuliiinasin 120 VAC vite 240 VAC ft 50 He vie 60 He © dgadnulnthdautuldgunsnbifalluu Resetable un Non Resettable ©) snansnufadieusirne Battery une Earth Faut © flgasnubiiananstdunute 00 dala (Battery) swia 7 AH fe 40 AH udausanttion Page 2017 ANTL-FIRE CO.,LTD. ‘raining Manual for Sequential Detection 3. mgldswuseuy 3.4 sflamenuaesssuunsetL Sequential Detection: mninwmusergunenlnrsetvachnten 2 Malunsaduntia ieutiew sedhaganny precischarge 3.2 unanmiinuuynonug SHP Pro uwzannthila SHP Pro dafuinnn LED utnsanraemetienwialll ACNORMAL © (ua9A LED Aunfiagins) euuedluanricanfdtefineeuat AC snubiifureuy edheunneas: ALARM, (men LED Aunsiinavins wiendliaess Peizo AauuFere) anvne alarm svifindta ulneninzasSunifequinenitidhanihuiaiinon zeuusevingannay alarm sunasata hagannay Pre-cischarge vite Release PRE-DISCHARGE (von LED Sunsfiasin nieaiiaes Peizo Raufhudewae) nae pre-discharge 3 FindlegunsninereduvitequnentiiDuwnitdudlavinenulursan Cross-Zone Sequential vio SOR zeUusziluamneentemnfiiimuals letiune immu ae inganmm: Release RELEASE (anon LED unas weailitus Peizo Aufhitwws) anni release azine duugnannne Pre-cischerge win Siniminvmwaes Manual Release SUPERVISORY (nan LED Awvifasfinevina nfeniTius Peizo haf) anvvaz supervisory seine Supenisory input Hew lumsieutusnaed seinewumanininenanesn faudiauevqlnsnl Supervisory RELEASE DISABLED wana LED @lufesAasnaielunsing Enable/Disable (SWS) sndrwnls Disable TROUBLE (usin LED AivMasdiners wiawthaes Peizo Marlaios) anane trouble aesfinidia reunion viu qaviniitqyn va Ground fauts via reusrunssualitia sanjrol vail aiaeusaree? Abort davis Trouble asinemArssundracionaud PANEL SILENCE sem LED Awfesiinains lenadind silence laviinreygnias Piezo veitus Fayryrousinasss Audible ‘ABORT aOR LED Au@asiinerine leit isnadin ABORT GROUND FAULT a0” LED Swifexfnarhs le zunittgyndatetenmnrnd Page 4 of 7 ANTIFIRE CO.,LTD. ‘Training Manual for Sequential Detection 33 dimishududlion indéomtudlionugntnutenltnad Silence Switch: —Wiuyaiteyqyroudieudadiau Bel, Hom wie Strobe Light (dndenariaeed) une Aiyqyioaussin Pezo wiowfuulBeudtyryre LED fhewuluanrashifindhitiin erin unedoldowtubih@umdusrtcinnks Reset Switch: ruil reset zeuumamtimyndyrynes output Ate une interrupting resettable power tienns ind reset # piezo azauazuaen LED ynusnnszhn, vaniusruy awtthganninalna sw4 Wdhuvindi@ennas die wvfoundinn s aruseyzeuutedyqy init Agent Release lus Solenoid AUTO-MANUAL Mode Switch dowquatndinludumnis Auto ssuusvirenuduldesdanmtumntslantntale demustingurluiiaumis Manual seuuseiinealsaeaemunnfslaun enn Manual Release uNnekR, deoyluaniay Manual Mode uazzeuuinanve Pre-cischarge suiddlaursuuediy annie aniinausies Abort uaviflemueininduandauinis Auto ruuastiunsniienss poe Ana umdsriesaldautnssuinds Sungate Abort AAS 3.4 udnmetlndiyayinudins © sin stence Vinyndyay nutusynadn (uilalstviatied) © udternmyatyyrnudies, Geithgamaeval dqyqyrniecuansiameanacdia (uansin dagenne release *¢ resound ayy pre-cischarge wou resound sqyqyiaueslurc sprinkler) © LED usmeanane alarm, watertiow, supervisory, pre-discharge, release iat trouble ssfinavine uiesinit nosing silence Hausavingliomiufude Page 6 of 7 ANTLFIRE CO.,LTD. 3,5 DIAGNOSTIC LED CODE DESIGNATORS inqnreniilagihuuse ti finduudaseqnulasdyyrouvin uouucanntidhui@neatsennsadanglé Taunasind Silence fl 3 Sunt aeusmauqnneniuu segment diagnostic LED. DETECT #1 ‘Training Manual for Sequential Detection | DETECT #2 TCH #4 TCH #2 i [aupieue #1 UDIBLE #2 AUDIBLE He 2 | AGENT RELEASE LEN | Abort input Invalid Abort 2 Alarm Action re aceasta Sain FE ERISA rere ra | Microcontroller _| cecund Fat i Power Fallure : AIC Brown-out (

Вам также может понравиться