Get the Right GC for Your Industry

Shimadzu was founded on the basis of "Technology for


Science" and we continue to take the initiative in the
analytical technology industry. From our absorption
spectrophotometers to our structure and surface analyzers
and chromatographs, our high-quality products are the
fruits of our original technologies.
As a wholly-owned subsidiary of Shimadzu Corporation,
established in 1875, Shimadzu Scientific Instruments, Inc.
continues to discover cutting-edge technologies to meet
customer needs and requirements that result in the
development of future instrumentation targeted at
Solutions for Science.
At SSI, you, the customer, are our number one priority
and we believe that quality is our responsibility.

SHIMADZU EUROPE LTD., OPERATION CENTER


Albert-Hahn-Strasse 6-10, D-47269 Duisburg, F.R. Germany
Phone: 49(203)7687-0
FAX: 49(203)7666-25

SHIMADZU SCIENTIFIC INSTRUMENTS, INC. SHIMADZU (ASIA PACIFIC) PTE LTD.


7102 Riverwood Drive, Columbia, MD 21046, USA 16 Science Park Drive #01-01 Singapore Science Park,
Phone: 410-381-1227 or 800-477-1227 Singapore 118227,
FAX: 410-381-1222 Republic of Singapore
http://www.ssi.shimadzu.com Phone: 65-778-6280
FAX: 65-779-2935
SHIMADZU CORPORATION, International Marketing Division
3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101, Japan SHIMADZU SCIENTIFIC INSTRUMENTS (OCEANIA) PTY LTD.
Phone: 81(3)3219-5641 Rydalmere Business Park, Unit T, 10-16 South Street,
FAX: 81(3)3219-5710 Rydalmere N.S.W. 2116, Australia
Cable Add.: SHIMADZU TOKYO Phone: 61(2)9684-4200
Overseas Telex No.: 0232-3291 (Answer Code: SHMDT J) FAX: 61(2)9684-4055
http://www.shimadzu.co.jp

www.ssi.shimadzu.com
Table of Contents

Hydrocarbon Processing Analyzers GC-14A LPG Analyzer .......................................................................... 9 Specialty Gas Analyzers
GC - 8AIT Natural Gas Analyzer #1 .................................................... 2 GC-2010 Simulated Distillation Analyzer ............................................ 9 GC-14A Nitrous Oxide Analyzer ........................................................ 15

GC - 8AIT Natural Gas Analyzer #2 .................................................... 2 GC-17A Simulated Distillation Analyzer .............................................. 9 GC-8A Nitrous Oxide Analyzer .......................................................... 15

GC-14A Natural Gas Analyzer #3 ........................................................ 2 GC-2010 PIANO Analyzer.................................................................... 9 GC-8A Chlorine Gas Analyzer 1
by ASTM D 1746 .......................................................................... 15
GC-2010 Natural Gas Analyzer by GPA Standard.............................. 2 GC-17A PIANO Analyzer .................................................................. 10
Shimadzu began building Gas GC-8A Chlorine Gas Analyzer 2
Chromatography products in 1955 and GC-17A Natural Gas Analyzer by GPA Standard ................................ 2 GC-2010 DHA Analyzer .................................................................... 10 by ASTM D 1746 .......................................................................... 15
remains committed to building the best GC-14A Natural Gas Analyzer by GPA Standard ................................ 2 GC-17A DHA Analyzer ...................................................................... 10 GC-17A Specialty Gas Analyzer 1...................................................... 16
GC products in the world. Throughout
our long history, the customer's needs GC-2010 Natural Gas Analyzer by GC-2010 Oxygenates in Gasoline by ASTM D 4815 ........................ 10 GC-17A Specialty Gas Analyzer 2 ......................................................16
GPA Standard with Fixed Gas Separation ...................................... 3
have always been central to all our design, GC-17A Oxygenates in Gasoline by ASTM D 4815 .......................... 11 GC-17A H2 Contaminants Analyzer....................................................17
manufacturing, and testing processes. GC-14A Natural Gas Analyzer by
GPA Standard with Fixed Gas Separation ...................................... 3 GC-14A Oxygenates in Gasoline by ASTM D 4815 .......................... 11 GC-14A H2 Contaminants Analyzer....................................................17
As part of this continuing commitment,
GC-2010 Natural Gas Analyzer by ASTM D 1945 .............................. 4 GC-2010 Refinery Gas by UOP 539 .................................................. 11 GC-8A H2 Contaminants Analyzer......................................................17
we developed the System GC program,
which provides our customers with the GC-17A Natural Gas Analyzer by ASTM D 1945 ................................ 4 GC-2010 Fast Refinery Gas ................................................................ 12 GC-17A N2 Contaminants Analyzer .................................................. 17
best applicated and fully configured GC GC-14A Natural Gas Analyzer by ASTM D 1945 ................................ 4 GC-2010 ASTM D 2504 Analyzer ...................................................... 12 GC-14A N2 Contaminants Analyzer ................................................ 17
products available anywhere. Configured
GC-2010 Extended Natural Gas Analyzer .......................................... 4 GC-17A ASTM D 2504 Analyzer ........................................................ 12 GC-8A N2 Contaminants Analyzer ....................................................17
and tested in Shimadzu's System
Integration Technology Lab, the system is GC-17A Extended Natural Gas Analyzer ............................................ 5 GC-14A ASTM D 2504 Analyzer ........................................................ 12 Environmental and Safety
shipped with proof of performance, GC-2010 ASTM D 2505 Analyzer ...................................................... 12 GC-17A TOGAS ..................................................................................18
GC-14A Extended Natural Gas Analyzer ............................................ 5
QA/QC and a field test standard.
GC-2010 Natural Gas and Gaseous Fuels GC-17A ASTM D 2505 Analyzer ........................................................ 12 GC-14A TOGAS ..................................................................................18
Upholding the Shimadzu tradition, the
Sulfur Analyzer by ASTM D 5504.................................................... 5
System GC group is uncompromising in GC-14A ASTM D 2505 Analyzer ........................................................ 12 GC-14A Greenhouse Gas Analyzer ....................................................18
the quest for excellence and in optimizing GC-17A Natural Gas and Gaseous Fuels
GC-17A Mine Gas Analyzer .............................................................. 18
GC-2010 ASTM D 3606 Analyzer ...................................................... 13
separations and making the products easy Sulfur Analyzer by ASTM D 5504.................................................... 5
to use. GC-17A ASTM D 3606 Analyzer ........................................................ 13 GC-14A Mine Gas Analyzer .............................................................. 18
GC-14A Natural Gas and Gaseous Fuels
Sulfur Analyzer by ASTM D 5504.................................................... 5 GC-14A ASTM D 3606 Analyzer ........................................................ 13 GC-14A Mud Logging, Well Gas Sampling Analyzer ........................ 18
Expect performance, quality and value
with System GC! GC-2010 Light Petroleum Sulfur Analyzer by ASTM D 5623 .............. 6 GC-2010 Sulfur and Fixed Gas Analyzer .......................................... 13 GC-14A Fuel Cell Analyzer ................................................................ 19
GC-17A Light Petroleum Sulfur Analyzer by ASTM D 5623................ 6 GC-17A Sulfur and Fixed Gas Analyzer ............................................ 13 GC-2010 Methane in Exhaust Analyzer by SAE J1511 .................... 19
GC-14A Light Petroleum Sulfur Analyzer by ASTM D 5623................ 7 GC-14A Sulfur and Fixed Gas Analyzer ............................................ 13 GC-17A Methane in Exhaust Analyzer by SAE J1511 ...................... 19
GC-2010 Natural Gas and Gaseous Fuels
Order your Sulfur Analyzer by ASTM D 6228.................................................... 7
GCMS QP-2010 Aromatics in Gasoline by ASTM D 5769 ................ 13 GC-14A Methane in Exhaust Analyzer by SAE J1511 ...................... 19

System GC today! GC-17A Natural Gas and Gaseous Fuels


GCMS QP-5000 Aromatics in Gasoline by ASTM D 5769 ................ 14

Sulfur Analyzer by ASTM D 6228.................................................... 8 GC-2010 Aromatics in Finished Gasoline by ASTM D 4420 ............ 14
Call 1-800-477-1227 or log-on GC-14A Natural Gas and Gaseous Fuels GC-14A Aromatics in Finished Gasoline by ASTM D 4420 .............. 14
to www.ssi.shimadzu.com Sulfur Analyzer by ASTM D 6228 .................................................. 8

for more information. GC-17A LPG Analyzer by GPA Standard ............................................ 8


GC-2010 Natural Gas Analyzer GC-2010 Natural Gas Analyzer by GPA Standard GC-14A Natural Gas Analyzer by GPA Standard with
by GPA Standard with Fixed Gas Separation Fixed Gas Separation
Method: GPA 2261 Method: GPA 2261 Method: GPA 2261
Part Number: 220-90851-20 Part Number: 220-90852-20 Part Number: 220-90852-14
Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5 Analytes: TCD1 - C6+, N2/air, CH4, CO2, C2, H2S, C3-C5 Analytes: TCD sample side - C6+, N2/air, CH4, CO2, C2, H2S,
Hydrocarbon Processing Analyzers Detectors: TCD TCD2 - H2, O2, N2, CH4, CO C3-C5 TCD reference - H2, O2, N2, CH4, CO
Columns: 3 packed Detectors: 2 TCDs Detectors: TCD using sample and reference
GC - 8AIT Natural Gas Analyzer #1 1 valve Columns: 5 packed Columns: 5 packed
Method: ASTM 1945 & 3588 This turnkey system is constructed according to The Gas Processors 2 valves 2 valves
Part Number: 220-90464-00 Association. C6+ components are grouped into a single peak using This turnkey system is constructed according to The Gas Processors This turnkey system is constructed according to The Gas Processors
Analytes: C6+, C1-C5, O2, N2, CO2 a pre-cut column, which is backflushed to elute the hexanes and Association. C6+ components are grouped into a single peak using Association. C6+ components are grouped into a single peak using
Detectors: TCD heavier as the first peak. Nitrogen/air, methane, carbon dioxide a pre-cut column, which is backflushed to elute the hexanes and a pre-cut column, which is backflushed to elute the hexanes and
Columns: 6 packed and ethane through n-pentane elute on forward flow of carrier gas heavier as the first peak. Nitrogen/air, methane, carbon dioxide heavier as the first peak. Nitrogen/air, methane, carbon dioxide
3 valves through the partition column. Analysis time is approximately 18 and ethane through n-pentane elute on forward flow of carrier gas and ethane through n-pentane elute on forward flow of carrier gas
This system is fully configured with a CR8A data processor pre- minutes. In most cases, He and H2 are either not present or pres- through the partition column, which is detected by the first TCD- through the partition column, which is detected by the sample side
pared for operation at the factory. Each system is a turnkey ana- ent in such small quantities that these need not be determined. 2010. The second gas sampling valve directs the natural gas sample of the TCD-14A. The second gas sampling valve directs the natu-
lyzer for performing natural gas assays of the components listed Must include a data processor or data station. to a molecular sieve 13X for separation of H2, O2, N2, CH4, CO ral gas sample to a molecular sieve 13X for separation of H2, O2,
with Compressibility, BTU and Specific Gravity calculations pro- which is detected by the second TCD-2010. Analysis time is approx- N2, CH4, CO which is detected by the reference side of the TCD-
vided for the appropriate compounds. Analysis time approximately GC-17A Natural Gas Analyzer imately 18 minutes. In most cases, He and H2 are either not pres- 14A . Analysis time is approximately 18 minutes. In most cases, He
18 minutes. In most cases, He and H2 are either not present or ent or present in such small quantities that these need not be and H2 are either not present or present in such small quantities
by GPA Standard determined. Must include a data processor or data station. that these need not be determined. Must include a data proces-
present in such small quantities that these need not be determined.
Method: GPA 2261 sor or data station.
Part Number: 220-90851-17
GC - 8AIT Natural Gas Analyzer #2 Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5
Method: GPA 2261 Detectors: TCD
Part Number: 220-90464-01 Columns: 3 packed
Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5 1 valve
Detectors: TCD This turnkey system is constructed according to The Gas Processors
Columns: 4 packed Association. C6+ components are grouped into a single peak using
1 valve a pre-cut column, which is backflushed to elute the hexanes and
This system is fully configured with a CR8A data processor pre- heavier as the first peak. Nitrogen/air, methane, carbon dioxide
pared for operation at the factory. Each system is a turnkey ana- and ethane through n-pentane elute on forward flow of carrier gas
lyzer for performing natural gas assays of the components listed through the partition column. Analysis time is approximately 18
with Compressibility, BTU and Specific Gravity calculations pro- minutes. In most cases, He and H2 are either not present or pres-
vided for the appropriate compounds. Analysis time approximately ent in such small quantities that these need not be determined.
18 minutes. In most cases, He and H2 are either not present or Must include a data processor or data station.
present in such small quantities that these need not be determined.
GC-14A Natural Gas Analyzer
GC-14A Natural Gas Analyzer #3 by GPA Standard
Method: ASTM 1945 Method: GPA 2261
Part Number: 220-90850-00 Part Number: 220-90851-14
Analytes: C6+, C3-C5, CO2, C2, O2, N2, CH4 Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5
Detectors: FID/TCD Detectors: TCD
Columns: 7 packed Columns: 3 packed
4 valves 1 valve
This turnkey system for natural gas incorporates a C6+ backflush This turnkey system is constructed according to The Gas Processors
and analyzes C3-C5 on the FID in that order. The valve timing then Association. C6+ components are grouped into a single peak using
allows for CO2, C2, O2, N2 and CH4 to be detected on the TCD a pre-cut column, which is backflushed to elute the hexanes and
respectfully. Must include a data station or data processor. heavier as the first peak. Nitrogen/air, methane, carbon dioxide
Compressibility, BTU and Specific Gravity calculations can be pro- and ethane through n-pentane elute on forward flow of carrier gas
vided for the appropriate compounds. Analysis time approximately through the partition column. Analysis time is approximately 18
60 minutes. In most cases, He and H2 are either not present or minutes. In most cases, He and H2 are either not present or pres-
present in such small quantities that these need not be determined. ent in such small quantities that these need not be determined.
Must include a data processor or data station. Natural Gas Analyzers by GPA Standard with Fixed Gas Separation

2 To order call 1-800-477-1227 www.ssi.shimadzu.com 3


GC-2010 Natural Gas Analyzer GC-14A Natural Gas Analyzer GC-17A Extended Natural Gas Analyzer
by ASTM D 1945 by ASTM D 1945 Part Number: 220-90854-17
Method: ASTM 1945 Method: ASTM 1945 Analytes: separate all components
Part Number: 220-90853-20 Part Number: 220-90853-14 Detectors: TCD/FID
Analytes: C6+, C3-C5, CO2, C2, O2, N2, CH4 Analytes: C6+, C3-C5, CO2, C2, O2, N2, CH4 Columns: 3 packed, 1 capillary
Detectors: TCD Detectors: TCD 2 valves
Columns: 4 packed Columns: 4 packed A detailed compositional analysis is often required to provide a
3 valves 3 valves better evaluation of the oil and natural gas field. The 2-valve Natural
The three-valve GC system is widely used for the routine analysis The three-valve GC system is widely used for the routine analysis Gas Extended Analysis System traps O2, N2, CH4, CO onto a
of natural gas. Basically the same as method GPA 2261, this turnkey of natural gas. Basically the same as method GPA 2261, this turnkey molecular sieve column and allows the separation of CO2, H2S,
analyzer groups C6+ components into a single peak using a pre- analyzer groups C6+ components into a single peak using a pre- and C2 on a porous polymer column for detection to a TCD-17A.
cut column, which is backflushed to elute the hexanes and heav- cut column, which is backflushed to elute the hexanes and heavier The 10-port sampling valve is set back to the load position which
ier as the first peak. The valve timing then allows for C3-C5, carbon as the first peak. The valve timing then allows for C3-C5, carbon allows the other hydrocarbons to be loaded on an SPL-17A injec-
dioxide, ethane, oxygen, nitrogen, and methane to elute to the dioxide, ethane, oxygen, nitrogen, and methane to elute to the tor in the split mode. The hydrocarbons are separated by a PIANO
TCD-2010 in that order. The final analysis time is approximately 20- TCD-14A in that order. The final analysis time is approximately 20- capillary column for detection by an FID-17A. Analysis time varies
30 minutes. In most cases, He and H2 are either not present or 30 minutes. In most cases, He and H2 are either not present or depending on the particular specifications set by the operator. In
present in such small quantities that these need not be determined. present in such small quantities that these need not be determined. most cases, He and H2 are either not present or present in such
Must include a data processor or data station. Must include a data processor or data station. small quantities that these need not be determined. Must include
a data processor or data station.
GC-17A Natural Gas Analyzer GC-2010 Extended Natural Gas Analyzer
by ASTM D 1945 GC-14A Extended Natural Gas Analyzer
Part Number: 220-90854-20 GC-17A Natural Gas and Gaseous Fuels Sulfur
Method: ASTM 1945 Analytes: separate all components Part Number: 220-90854-14 Analyzer by ASTM D 5504
Part Number: 220-90853-17 Detectors: TCD/FID Analytes: separate all components
Detectors: TCD/FID Method: ASTM 5504
Analytes: C6+, C3-C5, CO2, C2, O2, N2, CH4 Columns: 3 packed, 1 capillary
Columns: 3 packed, 1 capillary Part Number: 220-90855-17
Detectors: TCD 2 valves
2 valves Analytes: Sulfur Compounds
Columns: 4 packed A detailed compositional analysis is often required to provide a Detectors: SCD/FID
3 valves better evaluation of the oil and natural gas field. The 2-valve Natural A detailed compositional analysis is often required to provide a
Columns: 2 capillary
The three-valve GC system is widely used for the routine analysis Gas Extended Analysis System traps O2, N2, CH4, CO onto a better evaluation of the oil and natural gas field. The 2-valve Natural
1 valve
of natural gas. Basically the same as method GPA 2261, this turnkey molecular sieve column and allows the separation of CO2, H2S, Gas Extended Analysis System traps O2, N2, CH4, CO onto a
molecular sieve column and allows the separation of CO2, H2S, This turnkey system is designed for the determination of individ-
analyzer groups C6+ components into a single peak using a pre- and C2 on a porous polymer column for detection to a TCD-2010.
and C2 on a porous polymer column for detection to a TCD-14A. ual volatile sulfur-containing compounds in gaseous fuels includ-
cut column, which is backflushed to elute the hexanes and heav- The 10-port sampling valve is set back to the load position which
The 10-port sampling valve is set back to the load position which ing natural gas. It consists of a 10-port sampling valve with 2 sample
ier as the first peak. The valve timing then allows for C3-C5, carbon allows the other hydrocarbons to be loaded on an SPL-2010 injec-
allows the other hydrocarbons to be loaded on an SPL-14A injec- loops, an SPL-17A and 2 capillary columns that are in parallel. The
dioxide, ethane, oxygen, nitrogen, and methane to elute to the tor in the split mode. The hydrocarbons are separated by a PIANO
tor in the split mode. The hydrocarbons are separated by a PIANO sulfur compounds are detected by a sulfur chemiluminescence
TCD-17A in that order. The final analysis time is approximately 20- capillary column for detection by an FID-2010. Analysis time varies
capillary column for detection by an FID-14A. Analysis time varies detector and an FID-17A. The detection range is 0.01 to
30 minutes. In most cases, He and H2 are either not present or depending on the particular specifications set by the operator. In
depending on the particular specifications set by the operator. In 1000mg/m3 based upon the analysis of a 1-cm3 sample. Must
present in such small quantities that these need not be determined. most cases, He and H2 are either not present or present in such
most cases, He and H2 are either not present or present in such include a data processor or data station.
Must include a data processor or data station. small quantities that these need not be determined. Must include
a data processor or data station. small quantities that these need not be determined. Must include
a data processor or data station. GC-14A Natural Gas and Gaseous Fuels Sulfur
Analyzer by ASTM D 5504
GC-2010 Natural Gas and Gaseous Fuels Sulfur Method: ASTM 5504
Analyzer by ASTM D 5504 Part Number: 220-90855-14
Method: ASTM 5504 Analytes: Sulfur Compounds
Part Number: 220-90855-20 Detectors: SCD/FID
Analytes: Sulfur Compounds Columns: 2 capillary
Detectors: SCD/FID 1 valve
Columns: 2 capillary This turnkey system is designed for the determination of individ-
GC-2010 with AOC20i Autoinjector ual volatile sulfur-containing compounds in gaseous fuels includ-
1 valve
and AOC20s 150 Sample Carousel ing natural gas. It consists of a 10-port sampling valve with 2 sample
This turnkey system is designed for the determination of individ-
ual volatile sulfur-containing compounds in gaseous fuels includ- loops, an SPL-14A and 2 capillary columns that are in parallel. The
ing natural gas. It consists of a 10-port sampling valve with 2 sample sulfur compounds are detected by a sulfur chemiluminescence
loops, a SPL-2010 and 2 capillary columns that are in parallel. The detector and an FID-14A. The detection range is 0.01 to
sulfur compounds are detected by a sulfur chemiluminescence 1000mg/m3 based upon the analysis of a 1-cm3 sample. Must
detector and a FID-2010. The detection range is 0.01 to include a data processor or data station.
1000mg/m3 based upon the analysis of a 1-cm3 sample. Must
include a data processor or data station.

4 To order call 1-800-477-1227 www.ssi.shimadzu.com 5


GC-2010 Light Petroleum Sulfur Analyzer GC-17A Light Petroleum Sulfur Analyzer GC-14A Light Petroleum Sulfur Analyzer GC-2010 Natural Gas and Gaseous Fuels Sulfur
by ASTM D 5623 by ASTM D 5623 by ASTM D 5623 Analyzer by ASTM D 6228
Method: ASTM 5623 Method: ASTM 5623 Method: ASTM 5623 Method: ASTM 6228
Part Number: 220-90876-20 Part Number: 220-90876-17 Part Number: 220-90876-14 Part Number: 220-90877-20
Analytes: Sulfur Compounds Analytes: Sulfur Compounds Analytes: Sulfur Compounds Analytes: Sulfur Compounds
Detectors: SCD Detectors: SCD Detectors: SCD Detectors: FPD
Columns: 1 capillary Columns: 1 capillary Columns: 1 capillary Columns: 1 capillary
Valves: none Valves: none Valves: none 1 valve
This turnkey system covers the determination of volatile sulfur-con- This turnkey system covers the determination of volatile sulfur-con- This turnkey system covers the determination of volatile sulfur-con- This turnkey system provides for the determination of individual
taining compounds in light petroleum liquids. The system is appli- taining compounds in light petroleum liquids. The system is appli- taining compounds in light petroleum liquids. The system is appli- volatile sulfur-containing compounds in gaseous fuels using the
cable to distillates, gasoline motor fuels (including those containing cable to distillates, gasoline motor fuels (including those containing cable to distillates, gasoline motor fuels (including those containing FPD-2010 Flame Photometric Detector. The detection range for
oxygenates) and other petroleum liquids with a final boiling point oxygenates) and other petroleum liquids with a final boiling point oxygenates) and other petroleum liquids with a final boiling point sulfur compounds is from 0.02 to 20 mg/m3 of sulfur based upon
of approximately 230C. Detection of sulfur compounds is accom- of approximately 230C. Detection of sulfur compounds is accom- of approximately 230C. Detection of sulfur compounds is accom- the analysis of a 1ml sample using a gas sampling valve. Must
plished using a sulfur chemiluminescence detector. The applicable plished using a sulfur chemiluminescence detector. The applicable plished using a sulfur chemiluminescence detector. The applicable include a data processor or data station.
concentration range of individual sulfur species is 0.1 to 100mg/kg. concentration range of individual sulfur species is 0.1 to 100mg/kg. concentration range of individual sulfur species is 0.1 to 100mg/kg.
Must include a data processor or data station. Must include a data processor or data station. Must include a data processor or data station.

GC-17A LPG Analyzer by GPA Standard

GC-17A Light Petroleum Sulfur Analyzer by ASTM D 5623

6 To order call 1-800-477-1227 www.ssi.shimadzu.com 7


GC-17A Natural Gas and Gaseous Fuels Sulfur FPD-14 Flame Photometric Detector. The detection range for GC-14A LPG Analyzer GC-17A Simulated Distillation Analyzer
Analyzer by ASTM D 6228 sulfur compounds is from 0.02 to 20 mg/m3 of sulfur based upon Part Number: 220-90463-14 Method: ASTM 2887, 3710, 5307, 6352
the analysis of a 1ml sample using a gas sampling valve. Must Analytes: C6+, C3-C5 Part Number: 220-90863-17
Method: ASTM 6228
include a data processor or data station. Detectors: TCD Detectors: FID
Part Number: 220-90877-17
Analytes: Sulfur Compounds Columns: 3 packed Columns: 1 capillary
Detectors: FPD GC-17A LPG Analyzer by GPA Standard 2 valves Valves: none
Columns: 1 capillary Method: GPA 2177 The GC-14A Liquid Petroleum Gas System is a turnkey analyzer This turnkey analyzer comes with the appropriate hardware and
1 valve Part Number: 220-90861-17 that quantitates saturated and unsaturated C3-C5 hydrocarbons, software to perform any of the simulated distillation ASTM meth-
This turnkey system provides for the determination of individual Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5 and C6+ backflushed as one initial peak. In addition, the system ods, which are ASTM D 2887, ASTM D3710, ASTM D 5307, ASTM
volatile sulfur-containing compounds in gaseous fuels using the Detectors: TCD calculates the liquid volume %, specific gravity, and vapor pressure. D 6352, and ASTM D 6417. Includes enhanced data station, GC
FPD-17 Flame Photometric Detector. The detection range for sulfur Columns: 2 packed Analysis time is approximately 35 minutes. In most cases, He and Solution Software, and Petro Software.
compounds is from 0.02 to 20 mg/m3 of sulfur based upon the 2 valves H2 are either not present or present in such small quantities that
analysis of a 1ml sample using a gas sampling valve. Must include This turnkey system is constructed according to The Gas Processors these need not be determined. Must include a data processor or GC-2010 PIANO Analyzer
a data processor or data station. Association. C6+ components are grouped into a single peak using data station.
Part Number: 220-90864-20
a pre-cut column, which is backflushed to elute the hexanes and Detectors: FID
GC-14A Natural Gas and Gaseous Fuels Sulfur heavier as the first peak. Nitrogen/air, methane, carbon dioxide GC-2010 Simulated Distillation Analyzer Columns: 1 capillary
and ethane through n-pentane elute on forward flow of carrier gas Method: ASTM 2887, 3710, 5307, 6352 Valves: none
Analyzer by ASTM D 6228
through the partition column. In addition, the system calculates Part Number: 220-90863-20 The PIANO Analyzer is a single-column method that involves ana-
Method: ASTM 6228 the liquid volume %, specific gravity, and vapor pressure. Analysis Detectors: FID lyzing the naphtha sample for paraffins, olefins, naphthalenes, and
Part Number: 220-90877-14 time is approximately 18 minutes. In most cases, He and H2 are Columns: 1 capillary aromatics. This system comes with the appropriate hardware and
Analytes: Sulfur Compounds either not present or present in such small quantities that these Valves: none software to perform PIANO analysis. Includes enhanced data sta-
Detectors: FPD need not be determined. Must include a data processor or data
Columns: 1 capillary This turnkey analyzer comes with the appropriate hardware and tion, GC Solution Software, and Petro Software.
station. software to perform any of the simulated distillation ASTM
1 valve
methods, which are ASTM D 2887, ASTM D3710, ASTM D 5307,
This turnkey system provides for the determination of individual
ASTM D 6352, and ASTM D 6417. Includes enhanced data station,
volatile sulfur-containing compounds in gaseous fuels using the
GC Solution Software, and Petro Software.

GC-2010 PIANO Analyzer


GC-2010 Simulated Distillation Analyzer

8 To order call 1-800-477-1227 www.ssi.shimadzu.com 9


GC-17A PIANO Analyzer GC-17A DHA Analyzer GC-17A Oxygenates in Gasoline
Part Number: 220-90864-17 Method: ASTM 5134 by ASTM D 4815
Detectors: FID Part Number: 220-90866-17 Method: ASTM 4815
Columns: 1 capillary Analytes: Detailed Hydrocarbon Part Number: 220-90462-17
Valves: none Detectors: FID Analytes: 15 Oxygenated Compounds
The PIANO Analyzer is a single-column method that involves ana- Columns: 1 capillary Detectors: FID GC-2010 Refinery Gas by UOP 539
lyzing the naphtha sample for paraffins, olefins, naphthalenes, and Valves: none Columns: 1 packed, 1 capillary Method: UOP 539
aromatics. This system comes with the appropriate hardware and The Detailed Hydrocarbon Analysis System covers the determi- 1 valve Part Number: 220-90867-20
software to perform PIANO analysis. Includes enhanced data sta- nation of hydrocarbon components of petroleum naphthas by This turnkey system quantitates oxygenates in gasoline based on Analytes: H2, O2, N2, CO, CO2, C1-C4 hydrocarbons, C5
tion, GC Solution Software, and Petro Software. ASTM D 5134. This system comes with the appropriate hardware ASTM D 4815. Individual ethers are determined from 0.1 to 20.0 paraffins individually, and C5 olefins and C6+ hydrocarbons as
and software to perform DHA analysis. Includes enhanced data as %. Individual alcohols are determined from 0.1 to 12.0 mass %. a composite
GC-2010 DHA Analyzer station, GC Solution Software, and Petro Software. Analysis time is approximately 15 minutes. Must include a data Detectors: 2 TCDs
processor or data station. Columns: 5 packed
Method: ASTM 5134 4 valves
Part Number: 220-90866-20 GC-2010 Oxygenates in Gasoline by ASTM D 4815
GC-14A Oxygenates in Gasoline This automated analyzer determines the composite of gas sam-
Analytes: Detailed Hydrocarbon Method: ASTM 4815
ples, obtained from refining processes or natural sources. Non-
Detectors: FID Part Number: 220-90462-20 by ASTM D 4815 condensable gases, methane through C4 hydrocarbons and C5
Columns: 1 capillary Analytes: 15 Oxygenated Compounds Method: ASTM 4815 paraffins are reported individually, while C5 olefins and C6+ hydro-
Valves: none Detectors: FID Part Number: 220-90462-14 carbons are reported as a composite. H2S, if present, is not deter-
The Detailed Hydrocarbon Analysis System covers the determina- Columns: 1 packed, 1 capillary Analytes: 15 Oxygenated Compounds mined. Oxygen is not separated from argon. Usually argon is not
tion of hydrocarbon components of petroleum naphthas by ASTM 1 valve Detectors: FID present in refinery gas. Lower limit of detection is approximately
D 5134. This system comes with the appropriate hardware and soft- This turnkey system quantitates oxygenates in gasoline based on Columns: 1 packed, 1 capillary 0.05mol%. Analysis time is approximately 45 minutes. Must include
ware to perform DHA analysis. Includes enhanced data station, GC ASTM D 4815. Individual ethers are determined from 0.1 to 20.0 1 valve a data processor or data station.
Solution Software, and Petro Software. as %. Individual alcohols are determined from 0.1 to 12.0 mass %. This turnkey system quantitates oxygenates in gasoline based on
Analysis time is approximately 15 minutes. Must include a data ASTM D 4815. Individual ethers are determined from 0.1 to 20.0
processor or data station. as %. Individual alcohols are determined from 0.1 to 12.0 mass %.
Analysis time is approximately 15 minutes. Must include a data
processor or data station.

GC-2010 DHA Analyzer


GC-2010 Oxygenates in Gasoline by ASTM D4815

10 To order call 1-800-477-1227 www.ssi.shimadzu.com 11


GC-14A ASTM D 2504 Analyzer GC-2010 ASTM D 3606 Analyzer GC-17A Sulfur and Fixed Gas Analyzer
Method: ASTM 2504 Method: ASTM 3606 Part Number: 220-90871-17
Part Number: 220-90869-14 Part Number: 220-90870-20 Analytes: O2, N2, CO, CO2, COS, SO2
Analytes: H2, O2, N2, CO in non-condensable gases in C2 and lighter Analytes: Benzene, Toluene in Finished Gasoline Detectors: TCD
hydrocarbons Detectors: TCD Columns: 3 packed
Detectors: TCD/FID/Methanizer Columns: 2 packed 2 valves
Columns: 2 packed 1 valve This unit separates and quantifies CO2, COS, SO2, N2, O2, and
2 valves This automated analyzer is dedicated to the separation and quan- CO. Also, Cl2 and TiCl4 can be quantified. Detection limit is at the
This turnkey system is dedicated for the analysis of non-condens- titation of benzene and toluene in finished gasoline. Benzene can 0.01 % range. Analysis time is approximately 30 minutes. Must
able gases in C2 and lighter hydrocarbon products. H2, O2, N2, be determined between the levels of 0.1 and 5 volume % and include a data processor or data station.
and CO are determined at the part per million volume level. Must toluene can be determined between the levels of 2 and 20 volume
include a data processor or data station. %. Analysis time is approximately 10 minutes. Must include a data GC-14A Sulfur and Fixed Gas Analyzer
processor or data station.
Part Number: 220-90871-14
GC-2010 ASTM D 2505 Analyzer Analytes: O2, N2, CO, CO2, COS, SO2
Method: ASTM 2505 GC-17A ASTM D 3606 Analyzer Detectors: TCD
Part Number: 220-90869-20 Method: ASTM 3606 Columns: 3 packed
Analytes: CO2, CH4, ethane, acetylene and other hydrocarbons Part Number: 220-90870-17 2 valves
GC-2010 Fast Refinery Gas Detectors: TCD/FID/Methanizer Analytes: Benzene, Toluene in Finished Gasoline This unit separates and quantifies CO2, COS, SO2, N2, O2, and
Part Number: 220-90868-20 Columns: 2 packed Detectors: TCD CO. Also, Cl2 and TiCl4 can be quantified. Detection limit is at the
Analytes: H2, CO, CO2, O2, N2, H2S, C1-C5, C6+ 2 valves Columns: 2 packed 0.01 % range. Analysis time is approximately 30 minutes. Must
Detectors: TCD/FID This turnkey system is dedicated for the analysis of other hydro- 1 valve include a data processor or data station.
Columns: 6 packed carbons and CO2 in high purity ethylene. CO2, CH4, ethane, acety- This automated analyzer is dedicated to the separation and quan-
5 valves lene and other hydrocarbons are determined at the 1 to 500 part titation of benzene and toluene in finished gasoline. Benzene can GCMS QP-2010 Aromatics
This turnkey system is a dedicated analyzer for the analysis of refin- per million volume level. Must include a data processor or data sta- be determined between the levels of 0.1 and 5 volume % and
tion. toluene can be determined between the levels of 2 and 20 volume
in Gasoline by ASTM D 5769
ery gases. These gases include H2, O2, N2, CO, CO2, H2S, C1-
C5, and C6+ hydrocarbons reported as a composite. This system %. Analysis time is approximately 10 minutes. Must include a data Method: ASTM 5769
is configured with six packed columns, three sample loops, five processor or data station. Part Number: 220-90873-20
GC-17A ASTM D 2505 Analyzer Analytes: 24 Aromatics
valves, and FID/TCD. Analysis time is approximately 20 minutes.
Method: ASTM 2505 Detectors: MS
Must include a data processor or data station. GC-14A ASTM D 3606 Analyzer
Part Number: 220-90869-17 Columns: 1 capillary
Analytes: CO2, CH4, ethane, acetylene and other hydrocarbons Method: ASTM 3606 Valves: none
GC-2010 ASTM D 2504 Analyzer Detectors: TCD/FID/Methanizer Part Number: 220-90870-14 This GCMS system is used to make the determination of total aro-
Method: ASTM 2504 Columns: 2 packed Analytes: Benzene, Toluene in Finished Gasoline matics in finished gasoline, including reformulated gasoline (RFG)
Part Number: 220-90869-20 2 valves Detectors: TCD containing oxygenated blending components. This method is used
Analytes: H2, O2, N2, CO in non-condensable gases in C2 and This turnkey system is dedicated for the analysis of other hydro- Columns: 2 packed to identify and quantitate concentration, in liquid volume percent,
lighter hydrocarbons carbons and CO2 in high purity ethylene. CO2, CH4, ethane, acety- 1 valve for the following aromatics: benzene, 0.1 to 3%; toluene, 1 to 15%;
Detectors: TCD/FID/Methanizer lene and other hydrocarbons are determined at the 1 to 500 part This automated analyzer is dedicated to the separation and quan- and total (C6-C12) aromatics, 10 to 40%. ASTM Method D-5769
Columns: 2 packed per million volume level. Must include a data processor or data sta- titation of benzene and toluene in finished gasoline. Benzene can specifies the calibration of 24 aromatic components using 4 inter-
2 valves tion. be determined between the levels of 0.1 and 5 volume % and nal standards. A macro program calculates the uncalibrated aro-
This turnkey system is dedicated for the analysis of non-condens- toluene can be determined between the levels of 2 and 20 volume matic C10-C12 compounds and reports all concentrations of
able gases in C2 and lighter hydrocarbon products. H2, O2, N2, GC-14A ASTM D 2505 Analyzer %. Analysis time is approximately 10 minutes. Must include a data compounds of interest in volume percent.
and CO are determined at the part per million volume level. Must processor or data station.
Method: ASTM 2505
include a data processor or data station.
Part Number: 220-90869-14
Analytes: CO2, CH4, ethane, acetylene and other hydrocarbons GC-2010 Sulfur and Fixed Gas Analyzer
GC-17A ASTM D 2504 Analyzer Detectors: TCD/FID/Methanizer Part Number: 220-90871-20
Method: ASTM 2504 Columns: 2 packed Analytes: O2, N2, CO, CO2, COS, SO2
Part Number: 220-90869-17 2 valves Detectors: TCD
Analytes: H2, O2, N2, CO in non-condensable gases in C2 and This turnkey system is dedicated for the analysis of other Columns: 3 packed
lighter hydrocarbons hydrocarbons and CO2 in high purity ethylene. CO2, CH4, ethane, 2 valves
Detectors: TCD/FID/Methanizer acetylene and other hydrocarbons are determined at the 1 to 500 This unit separates and quantifies CO2, COS, SO2, N2, O2, and
Columns: 2 packed part per million volume level. Must include a data processor or data CO. Also, Cl2 and TiCl4 can be quantified. Detection limit is at the
2 valves station. 0.01 % range. Analysis time is approximately 30 minutes. Must
This turnkey system is dedicated for the analysis of non-condens- include a data processor or data station.
able gases in C2 and lighter hydrocarbon products. H2, O2, N2,
and CO are determined at the part per million volume level. Must
include a data processor or data station.

12 To order call 1-800-477-1227 www.ssi.shimadzu.com 13


GC-2010 Aromatics in Specialty Gas Analyzers
Finished Gasoline by ASTM D 4420
Method: ASTM 4420 GC-14A Nitrous Oxide Analyzer
Part Number: 220-90930-20 Part Number: 220-90856-14
Analytes: Aromatics to C8, C9+ Analytes: N2O
Detectors: 2 TCDs Detectors: ECD
Columns: 2 packed Columns: 7 packed Range of concentrations determined from 0.1 to 5%. This system
1 valve 2 valves is described in ASTM D 1746. Analysis time is approximately 10
This turnkey system utilizes two columns and two TCDs. A sample This analyzer is used for the rapid precise analysis for gases con- minutes. Must include a data processor or data station.
is injected into a polar liquid phase column. The nonaromatics are taining nitrous oxide. The combination of a pre-column backflush
directed to TCD #2. The column is backflushed immediately before system with an ECD eliminates interference from water and fluo-
the elution of benzene, and the aromatic portion is directed into rocarbons, and provides direct analysis for N2O in small sample GC-8A Chlorine Gas Analyzer 2
the nonpolar liquid phase column. The aromatic components elute volumes of ambient air. The system is completely turnkey and auto- by ASTM D 1746
according to their boiling points and are detected on TCD #1. mated, having been calibrated and tuned prior to shipment. Method: ASTM 1746
Immediately after the C8 aromatics have eluted, the flow through Analysis time is approximately 5 minutes. Must include a data Part Number: 220-90465-01
the nonpolar column is reversed to backflush the C9 and heavier processor or data station. Analytes: H2, O2, N2, CH4, CO, CO2
aromatics from the column through the detector. Detectors: TCD
GC-8A Nitrous Oxide Analyzer Columns: 9 packed
2 valves
Part Number: 220-90856-08
This turnkey system is for the analysis of H2, O2, N2, CH4, CO, and
Analytes: N2O
GC-14A Aromatics in CO2 impurities in chlorine gas. Chlorine concentration is not deter-
Detectors: ECD
Finished Gasoline by ASTM D 4420 Columns: 7 packed
mined. Components heavier than CO2 are backflushed to vent.
Method: ASTM 4420 Range of concentrations determined from 0.1 to 5%. This system
GCMS QP-5000 Aromatics 2 valves
Part Number: 220-90930-14 is described in ASTM D 1746. Analysis time is approximately 10
in Gasoline by ASTM D 5769 This analyzer is used for the rapid precise analysis for gases con- minutes. Must include a data processor or data station.
Analytes: Aromatics to C8, C9+ taining nitrous oxide. The combination of a pre-column backflush
Method: ASTM 5769 Detectors: TCD system with an ECD eliminates interference from water and fluo-
Part Number: 220-90873-50 Columns: 2 packed rocarbons, and provides direct analysis for N2O in small sample
Analytes: 24 Aromatics 1 valve volumes of ambient air. The system is completely turnkey and
Detectors: MS
This turnkey system utilizes two columns and a dual filament TCD. automated, having been calibrated and tuned prior to shipment.
Columns: 1 capillary
A sample is injected into a polar liquid phase column. The nonaro- Analysis time is approximately 5 minutes. Must include a data
Valves: none
matics are directed to the reference side of the TCD and vented to processor or data station.
This GCMS system is used to make the determination of total aro- atmosphere. The column is backflushed immediately before the
matics in finished gasoline, including reformulated gasoline (RFG) elution of benzene, and the aromatic portion is directed into the
containing oxygenated blending components. This method is used nonpolar liquid phase column. The aromatic components elute
GC-8A Chlorine Gas Analyzer 1
to identify and quantitate concentration, in liquid volume percent, according to their boiling points and are detected on the analyti- by ASTM D 1746
for the following aromatics: benzene, 0.1 to 3%; toluene, 1 to 15%; cal side of the TCD. Immediately after the C8 aromatics have eluted, Method: ASTM 1746
and total (C6-C12) aromatics, 10 to 40%. ASTM Method D-5769 the flow through the nonpolar column is reversed to backflush the Part Number: 220-90465-00
specifies the calibration of 24 aromatic components using 4 inter- C9 and heavier aromatics from the column through the detector. Analytes: H2, O2, N2, CH4, CO, CO2
nal standards. A macro program calculates the uncalibrated aro- Detectors: TCD
matic C10-C12 compounds and reports all concentrations of Columns: 9 packed
compounds of interest in volume percent. 2 valves
This turnkey system is for the analysis of H2, O2, N2, CH4, CO, and
CO2 impurities in chlorine gas. Chlorine concentration is not deter-
mined. Components heavier than CO2 are backflushed to vent.

GCMS QP 2010 Aromatics in Gasoline

GC-14A N2 Nitrous Oxide Analyzer

14 To order call 1-800-477-1227 www.ssi.shimadzu.com 15


GC-17A Specialty Gas Analyzer 1 GC-17A Specialty Gas Analyzer 2 GC-17A H2 Contaminants Analyzer
Part Number: 220-90857-17 Part Number: 220-90858-17 Part Number: 220-90859-17
Analytes: H2, O2, N2, CH4, CO, CO2, SF6, CF4, SiF4 Analytes: H2, O2, N2, CH4, CO, CO2, Light Hydrocarbons Analytes: Ar, N2, CH4, CO, CO2
Detectors: PDD Detectors: PDD Detectors: TCD
Columns: 3 packed Columns: 3 packed Columns: 3 packed
3 valves 3 valves 2 valves
The use of Ultra High Purity (UHP) specialty gases demands strin- The use of Ultra High Purity (UHP) specialty gases demands strin- This turnkey analyzer is dedicated to the separation and quantita-
gent product purity specifications particularly for the semi-con- gent product purity specifications particularly for the semi-con- tion of impurities in hydrogen. This system consists of a two-stream
ductor industry. The purity level is <500ppb for CO2, CO, HF, SF6, ductor industry. The purity level is <500ppb for H2, O2, N2, CH4, selection in which Ar, N2, CH4, CO, and CO2 are analyzed by a
CF4, Sif4, N2, and O2/AR. A confidence level of 50ppb has been CO, CO2 and light hydrocarbons. A GC-17A with a Valco Pulse TCD-17A. Analysis time is approximately 25 minutes. Must include
determined in daily practical analyses. A GC-17A with a Valco Pulse Discharge Detector (GC-PDD) is used to achieve the required a data processor or data station.
Discharge Detector (GC-PDD) is used to achieve the required detection levels. This turnkey system has a pre-column that delays
detection levels. All these impurities have a relatively higher vapor the specialty gas and the system is tuned to backflush the matrix GC-14A H2 Contaminants Analyzer
pressure than the specialty gases. The pre-column delays the spe- to waste. The system is designed to pre-cut the fixed gases.
cialty gas and the system is tuned to backflush the matrix to waste. However, H2 is allowed to pass to the detector. The analysis order Part Number: 220-90859-14
This system incorporates a column switching valve that allows the is H2, CO2, light hydrocarbons, O2, N2, CH4, and CO. Analysis Analytes: Ar, N2, CH4, CO, CO2
sample to be separated and analyzed by one of two columns at a time is approximately 20 minutes. Must include a data processor Detectors: TCD
time. Analysis time is approximately 10 minutes per column selec- or data station. Columns: 3 packed
tion. Must include a data processor or data station. 2 valves
This turnkey analyzer is dedicated to the separation and quantita-
tion of impurities in hydrogen. This system consists of a two-stream
selection in which Ar, N2, CH4, CO, and CO2 are analyzed by a
TCD-14A. Analysis time is approximately 25 minutes. Must include
a data processor or data station.

GC-8A H2 Contaminants Analyzer


Part Number: 220-90859-08 GC-14A N2 Contaminants Analyzer
Analytes: Ar, N2, CH4, CO, CO2 Part Number: 220-90860-14
Detectors: TCD Analytes: H2, O2
Columns: 3 packed Detectors: TCD
2 valves Columns: 1 packed
This turnkey analyzer is dedicated to the separation and quantita- 2 valves
tion of impurities in hydrogen. This system consists of a two-stream This turnkey analyzer is dedicated to the separation and quantita-
selection in which Ar, N2, CH4, CO, and CO2 are analyzed by a tion of impurities in nitrogen. This system consists of a two-stream
TCD-8A. Analysis time is approximately 25 minutes. Must include selection in which H2, and O2 are analyzed by a TCD-14A. Analysis
a data processor or data station. time is approximately 7 minutes. Must include a data processor or
data station.
GC-17A N2 Contaminants Analyzer
Part Number: 220-90860-17 GC-8A N2 Contaminants Analyzer
Analytes: H2, O2 Part Number: 220-90860-08
Detectors: TCD Analytes: H2, O2
Columns: 1 packed Detectors: TCD
2 valves Columns: 1 packed
This turnkey analyzer is dedicated to the separation and quantita- 2 valves
tion of impurities in nitrogen. This system consists of a two-stream This turnkey analyzer is dedicated to the separation and quantita-
selection in which H2 and O2 are analyzed by a TCD-17A. Analysis tion of impurities in nitrogen. This system consists of a two-stream
time is approximately 7 minutes. Must include a data processor or selection in which H2, and O2 are analyzed by a TCD-8A. Analysis
data station. time is approximately 7 minutes. Must include a data processor or
data station.
GC-17A Specialty Gas Analyzer

16 To order call 1-800-477-1227 www.ssi.shimadzu.com 17


GC-14A Greenhouse Gas Analyzer GC-14A Fuel Cell Analyzer GC-17A Methane in Exhaust Analyzer by SAE J1511
Part Number: 220-90804-00 Part number: 220-90862-14 Method: SAE J1511
Analytes: N2O, CH4, CO2 in air Analytes: H2, O2, N2, CH4, CO, CO2, Light Hydrocarbons Part Number: 220-90872-17
Detectors: ECD/FID Detectors: TCD/FID/Methanizer Analytes: CH4
Columns: 3 packed Columns: 2 packed Detectors: FID
3 valves Columns: 2 packed
3 valves
This model quantitates atmospheric trace gases, CO2, CH4, N2O, 1 valve
This turnkey system is designed for the analysis of gases pro-
in air matrix. This turnkey system is equipped with 2 sample loops, This turnkey system is constructed to the specifications of Society
duced from a catalytic reformer during the fuel cell process.
one delivers the sample to an ECD for N2O and CO2 detection of Automotive Engineers J1145. The analyzer separates methane
The system provides valuable information for the design, per-
and the other delivers the sample to an FID for the detection of from the other constituents of an exhaust gas sample. The con-
formance and optimization of the reformer operation. The
CH4. Generally, this system represents a useful and efficient tool centration of methane is determined with an FID with a detection
system determines H2, O2, N2, CH4, CO, CO2 and other key
for a large number of studies on greenhouse gases. Analysis time of approximately 1ppm. A complete cycle, from injection of one
species. The system consists of a GC-14 with TCD and FID with
is approximately 5 minutes. Must include a data processor or data sample to injection of a second sample, can be made in 30 sec-
methanizer, along with the valves and columns required for the
station. onds. Must include a data processor or data station.
application. Must include a data processor or data station.

GC-17A Mine Gas Analyzer GC-2010 Methane in Exhaust Analyzer by SAE J1511 GC-14A Methane in Exhaust Analyzer by SAE J1511
Part Number: 220-90827-17 Method: SAE J1511 Method: SAE J1511
Analytes: H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C2H2 Part Number: 220-90872-20 Part Number: 220-90872-14
Detectors: PDD/FID/Methanizer Analytes: CH4
Environmental and Safety Columns: 2 capillary
Analytes: CH4
Detectors: FID Detectors: FID
GC-17A TOGAS 2 valves Columns: 2 packed Columns: 2 packed
The GC-17A Mine Gas System offers a turnkey system for the 1 valve 1 valve
Method: ASTM 3612
Part Number: 220-90799-00 analysis of H2, O2, N2, CH4, CO, CO2, C2H6, C2H4, and C2H2. This turnkey system is constructed to the specifications of Society This turnkey system is constructed to the specifications of Society
Analytes: H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C2H2 This analyzer is similar to the GC-17A TOGAS. Features a GC-17A of Automotive Engineers J1145. The analyzer separates methane of Automotive Engineers J1145. The analyzer separates methane
Detectors: PDD/FID/Methanizer. Could substitute TCD for PDD with FID and PDD detectors, valves, columns, and methanizer. from the other constituents of an exhaust gas sample. The con- from the other constituents of an exhaust gas sample. The con-
Columns: 2 Capillary System operation is completely automated. Analysis time is centration of methane is determined with an FID with a detection centration of methane is determined with an FID with a detection
3 valves approximately 5-10 minutes depending on backflush of molesieve of approximately 1ppm. A complete cycle, from injection of one of approximately 1ppm. A complete cycle, from injection of one
5A column. Must include a data processor or data station. sample to injection of a second sample, can be made in 30 sec- sample to injection of a second sample, can be made in 30 sec-
The TOGAS GC-17A Dissolved Gas in Transformer Oil Analysis
onds. Must include a data processor or data station. onds. Must include a data processor or data station.
System offers a turnkey system for the analysis of H2, O2, N2, CH4,
CO, CO2, C2H6, C2H4, and C2H2 in mineral spirit-based trans- GC-14A Mine Gas Analyzer
former oil via direct injection. Meets ASTM D 3612-98 require- Part Number: 220-90827-14
ments. Features a GC-17A with FID and PDD detectors, valves, Analytes: H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C2H2
columns, methanizer, and patented oil stripper. System operation Detectors: TCD/FID/Methanizer
is completely automated. Analysis time is approximately 5-10 min- Columns: 6 packed
utes depending on backflush of high concentrated samples. Must 3 valves
include a data processor or data station.
The GC-14A Mine Gas System offers a turnkey system for the analy-
sis of H2, O2, N2, CH4, CO, CO2, C2H6, C2H4, and C2H2. This
GC-14A TOGAS analyzer is similar to the GC-14A TOGAS. Features a GC-14A with GC-17A with AOC20i Autoinjector and AOC20s 150 Sample Carousel
Method: ASTM 3612 FID and TCD detectors, valves, columns, and methanizer. System
Part Number: 220-90249-14 operation is completely automated. Analysis time is approximately
Analytes: H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C2H2 25 minutes. Must include a data processor or data station.
Detectors: PDD/FID/Methanizer
Columns: 6 packed GC-14A Mud Logging, Well Gas Sampling Analyzer
2 valves
Part Number: 220-90874-14
The TOGAS-14 Transformer Oil Gas Analysis System is completely Analytes: Stream 1 Hydrocarbons- (Total baseline measure-
turnkey, having been calibrated and tuned prior to shipment. The ment). Stream 2 C1-C6
GC-14A TOGAS gives accurate measurement of dissolved gases Detectors: 2 FIDs
which include H2, O2, N2, CH4, CO, CO2, C2H6, C2H4, and C2H2 Columns: 1 packed
in mineral spirit-based transformer oil via direct injection. Meets 2 valves
ASTM D 3612-98 requirements. Features a GC-14A with FID and
TCD detectors, valves, columns, methanizer, and patented oil strip-
per. System operation is completely automated. Analysis time is
approximately 25 minutes. Must include a data processor or data
station.

18 To order call 1-800-477-1227 www.ssi.shimadzu.com 19


Ordering Information
How to Order
Phone: For convenient ordering, use our toll-free number;
1-800-477-1227, ext. 1300
Mail: Mail your order to:
SHIMADZU
7102 Riverwood Drive
Columbia, MD 21046
Fax: Fax your purchase order to: 410-381-1222
Online: Visit our website, http://store.shimadzu.com, for more information
or to contact your local sales office/representative.
When you order, be sure to include:
Purchase order number
Your billing address
Your shipping address
Our catalog number and the product description
Your name and telephone number

Terms
We welcome all orders of any size.
Terms of payment are net 30 days.

Returns
Returns of any products must be authorized in advance.
Please contact SHIMADZU for a return authorization number and forwarding
instructions. All claims must be made within 60 days of shipping. Report shipping
damage to carrier.
Keep containers and packaging materials until inspection has been made.
Order today! Call 1-800-477-1227 or log-on to www.ssi.shimadzu.com for more information.
Warranty
Information presented in this catalog is correct and reliable to the best of our
knowledge and belief, but is not guaranteed to be so.
SHIMADZU shall not, under any circumstances, be held liable for any incidental,
consequential or compensatory damage arising from the use of, or in conjunction
with its products. The maximum liability which can be assumed by SHIMADZU shall
be limited to the invoice price of the product.