(29) Et6
March 2017
DSD/ESD
Shear Load Connectors
for the Construction Industry
Shear Load Connectors
Efficiently transfer shear load across movement joints
in concrete
Reinforced concrete is an required. The sleeve is simply
Building
important construction material. nailed to the formwork ensuring
Information
It offers strength, durability and subsequent alignment with the
Modelling
can be formed into a variety of dowel, essential for effective
shapes. Concrete structures are movement. BIM objects of Ancon products are
designed with expansion and They are manufactured from now available to download from
contraction joints at appropriate stainless steel to ensure a high either www.ancon.co.uk/BIM
places to allow movement to degree of corrosion resistance or the NBS National
take place. The design of the with no requirement for additional BIM Library.
joint is important for the overall protection.
design to function correctly.
In most cases, dowelled or keyed
Ancon shear load connectors joints can be replaced by joints
offer significant advantages over incorporating Ancon shear load
plain dowels. These connectors connectors. They can be used
are more effective at transferring for movement joints in floor
load and allowing movement to slabs, suspended slabs, and for
take place, easier to fix on site replacing double columns and
and can prove a more cost- beams at structural movement
effective solution. joints.
Each connector is a two-part Applications in civil engineering
assembly comprising a sleeve include joints in bridge parapets,
and a dowel component. bridge abutments and diaphragm
Installation is a fast and accurate wall construction.
process, drilling of either
formwork or concrete is not
Contents
Dowelled and Keyed Joints 4 DSD and DSDQ Connectors 10-14
Ancon Solutions to Joints 5 ESD, ESDQ, ED
Ancon Shear Connector Range 6-7 and Acoustic Connectors 15-18
3
DSD/ESD Shear Load Connectors
Compressible
joint filler
Dowel bar
Debonding
sleeve
Misaligned dowels can result in cracking away from the expansion joint
Design
Resistance kN 202.5 191.4
5
DSD/ESD Shear Load Connectors
End cap
Guide tube
Ancon Shear Load Connectors
The DSD range of connectors offers significant
advantages over plain dowels. Each connector
Web plate is a two-part assembly comprising a sleeve
and a dowel component. Installation is a fast
and accurate process, drilling of either
formwork or concrete is not required. The
sleeve is simply nailed to the formwork
Cross dowels
ensuring subsequent alignment with the dowel,
essential for effective movement.
End plate with They are manufactured from stainless steel to
Dowel bar nail holes ensure a high degree of corrosion resistance
DSD
Longitudinal with no requirement for additional protection.
movement
Free software is available from Ancon that
simplifies the design of movement joints in
reinforced concrete. For a given application,
Ancons design program will calculate the
Lateral movement
or rotation size and quantity of shear load connectors
required, the edge distance and spacings at
which they should be installed, and details of
leeve within
S the local reinforcement.
rectangular box
section Ancon DSD
The Ancon DSD is the original two-part, double
dowel, shear load connector. The two dowels
are Duplex stainless steel bar. The dowel
component can move longitudinally within the
sleeve to accommodate movement. The
connector is available in ten standard sizes and
has design resistances from around 20kN to
over 950kN. The larger connectors can be
DSDQ used in joints up to 60mm wide. Larger joints
Longitudinal
movement can be accommodated using special dowels.
Please contact Ancons Technical Department
for further information.
Ancon DSDQ
The Ancon DSDQ shear load connector
uses the same dowel component as the Ancon
Ancon DSDQ Shear Connectors allowing Ancon DSDQ Shear Connectors allowing
movement in two directions DSD, but the cylindrical sleeve is contained
rotation
within a rectangular box section to allow
Ancon DSDQ lateral movement in addition to the longitudinal
Shear Connectors movement. There are nine standard sizes
which have design resistances from around
Slab movement
will be in opposite 30kN to over 950kN.
directions in this area
Plan
6 Tel: +44 (0) 114 275 5224 www.ancon.co.uk
A range of stainless steel single dowel shear ESD
connectors is also available.
Ancon ESD
The Ancon ESD shear load connector is used
where loads are small, but where alignment is
critical. It is available in four sizes with each size
available in two lengths. The dowel component
is Duplex stainless steel bar.
Ancon ESDQ
The Ancon ESDQ shear load connector uses
the same dowel as the ESD, but the cylindrical ESDQ
sleeve is contained within a rectangular box
section to allow lateral movement or rotation in
addition to longitudinal movement.
Ancon ED
The Ancon ED is a low cost dowel connector
for use in floor slabs where alignment is ED
important but loads are small. The single dowel
shear connector is available in four sizes with
each size available in two lengths. The sleeve
component is made from a durable plastic and
features an integral nail plate. The dowel
component is Duplex stainless steel.
Ancon Staisil-HLD Acoustic Dowel
The Ancon Staisil-HLD features a 22mm
diameter stainless steel dowel, located in a
sound absorbing sleeve. It is designed to
reduce the oscillation of impact sound through
a building by isolating concrete components,
Staisil-HLD
such as stair landings from the main structural
frame. A decoupled concrete configuration,
featuring Staisil-HLDs, offers an 18dB impact
sound reduction over a rigid concrete floor
connection, verified by the Fraunhofer Institute.
Ancon HLD/HLDQ
The Ancon HLD is a two-part, high load, shear connector for thinner slabs
outside the application of the DSD range. The connector is available in seven
sizes with design resistances from 24kN to over 500kN. The larger connectors HLD
can be used in joints up to 60mm wide.
Ancon E-HLD
The Ancon E-HLD joins new concrete slabs to existing concrete walls and
comprises a stainless steel dowel and a high strength, stainless steel sleeve.
It is designed to transfer shear load where new slabs are connected to
diaphragm walls or secant pile walls in basement construction. The dowel
component is resin-fixed into the wall. It is available in seven standard sizes E-HLD
and can be used in a slab thickness from 160mm and joints up to 60mm wide.
7
DSD/ESD Shear Load Connectors
Direction
of load
Installation Procedure
The two-part assembly of all Ancon shear connectors removes the need for drilling formwork on
site, supporting dowel bars and fitting debonding sleeves and end caps. The installation is a fast
and accurate process.
1 2
When the concrete has achieved sufficient Position compressible joint filler of the Push the dowel component through the joint
strength, strike the shuttering. Peel off or appropriate width, for applications where filler (if applicable) until it is fully located in the
puncture the label to reveal the holes for the movement is expected between the two sleeve component. It may be necessary to tap
dowels. Where Q versions are being used, the sections of concrete. the dowel component to overcome the dimple
label should only be punctured enough to allow which pinch holds the dowel in the sleeve and
the dowel into the cylindrical sleeve to prevent prevents dislocation when the concrete is
debris entering the box section. vibrated.
1000
900
800
700
600
VRd (kN)
500
400
DSD 450
300 DSD 400
DSD 150
DSD 130
200 DSD 100
DSD 75
DSD 65
100
DSD 50
DSD 30
0 DSD 25
10 mm 20 mm 30 mm 40 mm 50 mm 60 mm
Joint Widths (mm)
Note: For more detailed information please see page 11.
Ancon ESD VRd Design Resistance (kN) for Various Joint Widths (mm) at the Maximum Slab Thickness (mm) in C30/37 Concrete
80
70
60
50
VRd (kN)
40
30
20
10
ESD 25
ESD 20
ESD 15
0 ESD 10
10 mm 20 mm 30 mm 40 mm
Joint Widths (mm)
Note: For more detailed information please see page 17.
9
DSD/ESD Shear Load Connectors
DSD/DSDQ Options for Longitudinal Bars (No. bars top and bottom) Spacing (mm)
25* 1 H10 f1 = 60mm
30 2 H10 f1 = 60mm; f2 = 60mm
2 H10 f1 = 60mm; f2 = 70mm
50
2 H12 f1 = 60mm; f2 = 70mm
2 H10 f1 = 60mm; f2 = 70mm
65
2 H12 f1 = 60mm; f2 = 70mm
3 H10 f1 = 60mm; f2 = 70mm
75
2 H12 f1 = 60mm; f2 = 70mm
3 H12 f1 = 60mm; f2 = 70mm
100
2 H16 f1 = 60mm; f2 = 70mm
3 H12 f1 = 60mm; f2 = 70mm
130
2 H16 f1 = 60mm; f2 = 70mm
150 4 H16 f1 = 60mm; f2 = 70mm
400 5 H16 f1 = 60mm; f2 = 100mm
450 6 H16 f1 = 60mm; f2 = 100mm
Based on C30/37 Concrete, maximum slab depth (see page 11) 20mm joint and 30mm cover
DSD/DSDQ Options for Main Reinforcement (No. U bars each side) Spacing (mm)
25* 2 H10 e1 = 50mm; e2 = 98mm
3 H10 e1 = 50mm; e2 = 52mm
30
2 H12 e1 = 50mm; e2 = 95mm
4 H10 e1 = 50mm; e2 = 35mm
50
3 H12 e1 = 50mm; e2 = 48mm
For walls, the reinforcement is repeated as in 4 H10 e1 = 60mm; e2 = 40mm
65
3 H12 e1 = 60mm; e2 = 56mm
the tables but with links replacing the U-bars. 5 H10 e1 = 60mm; e2 = 39mm
75
Links should extend between the near face 4 H12 e1 = 60mm; e2 = 50mm
and the far face of the wall reinforcement. 5 H12 e1 = 60mm; e2 = 45mm
100
3 H16 e1 = 60mm; e2 = 70mm
130 4 H16 e1 = 60mm; e2 = 81mm
150 6 H16 e1 = 60mm; e2 = 101mm
Wall
400 7 H16 e1 = 60mm; e2 = 114mm
Reinforcement
450 9 H16 e1 = 60mm; e2 = 87mm
Longitudinal
reinforcement Main DSD/DSDQ Options for Longitudinal Bars (No. bars top and bottom) Spacing (mm)
above reinforcement 25* 1 H10 f1 = 60mm
and below each side of 30 2 H10 f1 = 60mm; f2 = 60mm
connectors connector 2 H10 f1 = 60mm; f2 = 70mm
50
2 H12 f1 = 60mm; f2 = 70mm
2 H10 f1 = 60mm; f2 = 70mm
65
2 H12 f1 = 60mm; f2 = 70mm
3 H10 f1 = 60mm; f2 = 70mm
75
2 H12 f1 = 60mm; f2 = 70mm
3 H12 f1 = 60mm; f2 = 70mm
100
2 H16 f1 = 60mm; f2 = 70mm
4 H12 f1 = 60mm; f2 = 70mm
130
2 H16 f1 = 60mm; f2 = 70mm
150 4 H16 f1 = 60mm; f2 = 70mm
400 5 H16 f1 = 60mm; f2 = 100mm
450 6 H16 f1 = 60mm; f2 = 100mm
*DSD only
12 Tel: +44 (0) 114 275 5224 www.ancon.co.uk
Cover
Minimum cover Cu to local reinforcement is to
the recommendations of BS EN 1992.
Maximum cover Cf to face of slab is as shown
below:
Ref Max Cover Ref Max Cover
DSD to Face Cf (mm) DSDQ to Face Cf (mm)
25 40 - -
30 40 30 40
50 40 50 40
65 40 65 40
75 40 75 40
100 50 100 65
130 50 130 70
150 70 150 70
400 80 400 80
450 50 450 50
Cu
Cu
Cover Cf
13
DSD/ESD Shear Load Connectors
Centres Maximum
lateral
movement
Projection Anchor bar Anchor bar Anchor bar
lengths Sleeve length lengths Sleeve length lengths
Dowel length
Dimensions
Ref Dowel Component DSD Sleeve DSDQ Sleeve
DSD Overall Dowel Dowel Dowel Anchor Bar
Anchor Bar Overall Anchor Bar Anchor Bar Overall Anchor Bar Anchor Bar Lateral
DSDQ Length Dia Centres Projection Position Lengths Length Position Lengths Length Position Length Movnt
25* 250 14 40 120 31 50/110 120 28 50/110 - - - -
30 260 16 48 120 31 50/110 120 28 50/110 140 33 70 +/-12.5
50 280 18 50 130 31 50/130 135 28 50/130 160 33 70 +/-12.8
65 300 20 65 150 31 50/130 155 28 50/130 175 33 70 +/-10.5
75 340 22 75 150 33 50/150 155 31 50/150 175 33 120 +/-10.3
100 400 30 100 210 34 80/170 210 36 80/170 240 54 170 +/-20.75
130 470 35 105 260 34 80/170 265 36 80/170 290 59 170 +/-18.25
150 550 42 120 270 54 80/210 275 39 80/210 305 54 170 +/-10.85
400 660 52 160 330 70 130/300 335 70 130/300 355 64 300 +/-15.25
450 690 65 180 360 80 130/300 370 80 130/300 400 89 300 +/-27.5
Notes: *DSD only. All dimensions are in millimetres (mm).
76x82
Ancon ED Shear Connectors Dimensions
Dowel Component ED Sleeve Ref Dowel Dowel Sleeve
ED Length Diameter Length
10 300 300 20 170
70x78
10 400 400 20 220
Dowel
diameter 15 300 300 22 170
15 400 400 22 220
20 300 300 30 170
Dowel length 80 Sleeve length 20 400 400 30 220
25 350 350 35 195
25 470 470 35 260
95mm 82mm
160mm
310mm 90mm 170mm 12mm 76mm 12mm
Slab
Thickness
15
DSD/ESD Shear Load Connectors
VRd Design Resistance (kN) for Various Joint Widths (mm) and Slab Thickness (mm) using C25/30 Concrete
Slab Thickness Product Maximum Width of Joint (mm)
(mm) Reference 10 20 30 40
180* 25.6 25.6 22.4 19.7
200 26.7 25.7 22.4 19.7
220 ESD/ESDQ 10 26.7 25.7 22.4 19.7
240 26.7 25.7 22.4 19.7
260 26.7 25.7 22.4 19.7
280 26.7 25.7 22.4 19.7
180* 28.7 28.7 28.1 24.9
200 32.3 31.9 28.1 24.9
220 32.3 31.9 28.1 24.9
ESD/ESDQ 15
240 32.3 31.9 28.1 24.9
260 32.3 31.9 28.1 24.9
280 32.3 31.9 28.1 24.9
220* 47.3 47.3 47.3 47.3
240 54.9 54.9 54.9 52.7
260 60.0 60.0 57.8 52.7
ESD/ESDQ 20
280 60.0 60.0 57.8 52.7
300 60.0 60.0 57.8 52.7
350 60.0 60.0 57.8 52.7
240* 56.8 56.8 56.8 55.7
260 65.0 65.0 61.5 55.7
280 ESD/ESDQ 25 73.7 68.0 61.5 55.7
300 75.4 68.0 61.5 55.7
350 75.4 68.0 61.5 55.7
400 75.4 68.0 61.5 55.7
Slab Thickness Product Maximum Width of Joint (mm)
(mm) Reference 10 20 30 40
180* 25.6 25.6 22.4 19.7
200 26.7 25.7 22.4 19.7
220 26.7 25.7 22.4 19.7
ED 10
240 26.7 25.7 22.4 19.7
260 26.7 25.7 22.4 19.7
280 26.7 25.7 22.4 19.7
180* 28.7 28.7 28.1 24.9
200 32.3 31.9 28.1 24.9
220 32.3 31.9 28.1 24.9
ED 15
240 32.3 31.9 28.1 24.9
260 32.3 31.9 28.1 24.9
280 32.3 31.9 28.1 24.9
220* 47.3 47.3 47.3 47.3
240 54.9 54.9 54.9 52.7
260 ED 20 60.0 60.0 57.8 52.7
280 60.0 60.0 57.8 52.7
300 60.0 60.0 57.8 52.7
350 60.0 60.0 57.8 52.7
240* 56.8 56.8 56.8 55.7
260 65.0 65.0 61.5 55.7
280 73.7 68.0 61.5 55.7
ED 25
300 75.4 68.0 61.5 55.7
350 75.4 68.0 61.5 55.7
400 75.4 68.0 61.5 55.7
* Refers to the minimum slab depth Hmin for each connector type.
Slab Thickness Product Maximum Width of Joint (mm)
(mm) Reference 10 20 30 40 50 60
180 35 35 35 34 33 32
200 37 37 37 37 37 37
220 39 39 39 39 39 39
240 Staisil-HLD 39 39 39 39 39 39
260 39 39 39 39 39 39
280 39 39 39 39 39 39
300 39 39 39 39 39 39
320 39 39 39 39 39 39
17
DSD/ESD Shear Load Connectors
e2 e2 e1 e1 e2 e2
ESDReinforcement Details
Longitudinal
Local reinforcement is required around each reinforcement
connector to guarantee that the forces are above connectors
transferred between the connectors and the
concrete. Correct detailing in accordance with Longitudinal
appropriate design codes and the reinforcement
below connectors
recommendations provided here will ensure
Main
Ancon ESD, ESDQ, ED and Staisil connectors reinforcement
attain their full capacity. each side of connector
Based on a minimum of C25/30 Concrete, maximum slab depth (see page 16) and
20mm joint
Options for Main Reinforcement
ED/ESD/ESDQ (No. U bars each side) Spacing (mm)
2 H10 e1 = 35mm; e2 = 50mm
10
1 H12 e1 = 35mm
2 H10 e1 = 50mm; e2 = 40mm
15
2 H12 e1 = 50mm; e2 = 40mm
20 2 H12 e1 = 40mm; e2 = 30mm
25 3 H12 e1 = 45mm; e2 = 45mm
3 H10 e1 = 70mm; e2 = 74mm
Staisil-HLD
2 H12 e1 = 70mm; e2 = 139mm
Cover
Cf Cf
Cu
Cu
19
Masonry Support Systems
Lintels
Masonry Reinforcement
Windposts and Parapet Posts
Wall Ties and Restraint Fixings
Channel and Bolt Fixings
Tension and Compression Systems
Insulated Balcony Connectors
Shear Load Connectors
Punching Shear Reinforcement
Reinforcing Bar Couplers
Reinforcement Continuity Systems
Stainless Steel Fabrications
Flooring andFormed Sections
Refractory Fixings
Ancon Building Products Ancon Building Products Ancon (Schweiz) AG Ancon GmbH
President Way, President Park 98 Kurrajong Avenue Gewerbezone Widalmi 10 Bartholomusstrasse 26
Sheffield S4 7UR Mount Druitt 3216 Ried bei Kerzers 90489 Nuremberg
United Kingdom Sydney NSW 2770 Switzerland Germany
Tel: +44 (0) 114 275 5224 Australia Tel: +41 (0) 31 750 3030 Tel: +49 (0) 911 955 1234 0
Fax: +44 (0) 114 276 8543 Tel: +61 (0) 2 8808 3100 Fax: +41 (0) 31 750 3033 Fax: +49 (0) 911 955 1234 9
Email: info@ancon.co.uk Fax: +61 (0) 2 9675 3390 Email: info@ancon.ch Email: info@anconbp.de
Visit: www.ancon.co.uk Email: info@ancon.com.au Visit: www.ancon.ch Visit: www.anconbp.de
Follow on Twitter: @AnconUK Visit: www.ancon.com.au
Ancon (Middle East) FZE Ancon Building Products Ancon Building Products
PO Box 17225 2/19 Nuttall Drive GesmbH
Jebel Ali Hillsborough Puchgasse 1
Dubai Christchurch 8022 A-1220 Vienna
United Arab Emirates New Zealand Austria
Tel: +971 (0) 4 883 4346 Tel: +64 (0) 3 376 5205 Tel: +43 (0) 1 259 58 62-0
Fax: +971 (0) 4 883 4347 Fax: +64 (0) 3 376 5206 Fax: +43 (0) 1 259 58 62-40
Email: info@ancon.ae Email: info@ancon.co.nz Email: info@ancon.at
Visit: www.ancon.ae Visit: www.ancon.co.nz Visit: www.ancon.at
The construction applications and details provided in this literature are indicative only. In every case, project working
These products are available from: details should be entrusted to appropriately qualified and experienced persons.
Whilst every care has been exercised in the preparation of this document to ensure that any advice, recommendations or
information is accurate, no liability or responsibility of any kind is accepted in respect of Ancon Building Products.
With a policy of continuous product development Ancon Building Products reserves the right to modify product design and
specification without due notice.