Вы находитесь на странице: 1из 17

FEAST Software Pvt.

Ltd RCC One-Way Slab

SOFTWARE REQUIREMENTS & SPECIFICATIONS

For

RCC one way Slab design by WSM

Client : FEAST Software Pvt. Ltd

Project : DOS: Civil

Description : Analysis of RCC Slab by WSM

Version : 1.0

Reason for Modification : New format

Assignment Name Start Date End Date Signature

SRS preparation: Aniket 08/05/2017 08/05/2017

SRS testing :

Code development :

Code testing:

GUI development :

GUI testing:

1
FEAST Software Pvt. Ltd RCC One-Way Slab

Table of Contents

Sr. No. TITLE Page No.


Table of Contents

Revision History

List of abbreviations

Input

Output

Design/Analysis steps

Flow chart

Parameter constraints

GUI messages

GUI layout

2
FEAST Software Pvt. Ltd RCC One-Way Slab

Revision History

Signature
Sr. No. Name Date Reason for change Version No of Tech
Director

1 Aniket 09/05/2017 New R0

3
FEAST Software Pvt. Ltd RCC One-Way Slab

List of abbreviations

Sr.
Symbol Description Unit
No.

1 b Slab width, 1000mm always mm

2 d Effective Depth mm

3 t Thickness of slab mm

4 c Effective Cover (D-d) mm

5 cbc Permissible stresses in Concrete MPa

6 st Permissible stresses in steel Mpa

7 Diameter of Steel Bars mm

8 n Number of Steel Bars ---

9 Ast Area of tensile steel = /4 2 mm2

10 M Moment of Resistance kN-m

11 xc Critical Depth of Neutral Axis mm

12 xa actual Depth of Neutral Axis mm

13 C Total Compression N

14 T Total Tension N

15 z Lever Arm mm

4
FEAST Software Pvt. Ltd RCC One-Way Slab

1. Inputs

RCC one way Slab (Design)

i. Width of slab (b)=1000mm always mm


ii. Effective Depth of beam (d) mm
Or Overall depth (D) and cover (C) mm

iii.
Moment of resistance kNm
Or

Live load kN/m2

Floor finishes load kN/m2

iv. Material
Permissible stresses in Concrete (cbc) MPa

Permissible stresses in steel ( st) MPa

v. Length of span (l) mm


vi. Effective cover ( d' ) mm

vii. % pt %

2 Outputs

RCC One-Way Slab (Design)

1. Steel stress of service loads ( f s ) (Calculated in Step 3.1) Mpa

2. Modification factor (MF) (Calculated in Step 3.1)


3. Effective depth provided ( d provided ) (Calculated in Step 3.2) mm

4. Thickness of slab (t) (Calculated in Step 3.2) mm


5. Design moment (M) (Calculated in Step 3.3) kN-m
6. Modular ratio (m) (Calculated in Step 3.1)

5
FEAST Software Pvt. Ltd RCC One-Way Slab

7. Depth of Neutral Axis (xc) (Calculated in Step 3.2) mm


8. Lever Arm (z) (Calculated in Step 3.3)
9. Design shear force (V) (Calculated in Step 3.3) kN-m
10.Maximum depth of Neutral axis (Xu max) (Calculated in Step 3.4) mm
11.(Q) (Calculated in Step 3.4)
12.Effective depth required ( d required ) (Calculated in Step 3.4) mm

13.Area of main steel ( Ast main ) (Calculated in Step 3.5) mm2

14.Spacing ( S main ) (Calculated in Step 3.5) mm

15.Area of distribution steel ( Ast dis ) (Calculated in Step 3.5) mm2

16.Spacing ( S dis ) (Calculated in Step 3.5) mm

17.%pt provided (%pt) (Calculated in Step 3.6) %pt


18.k,tc,tv (Calculated in Step 3.6) Mpa
19.%pt, fs, MF (Calculated in Step 3.8) %,Mpa
20.(l/d) permissible, (l/d) actual (Calculated in Step 3.8)

6
FEAST Software Pvt. Ltd RCC One-Way Slab

3. Design Steps

3.1 Steel stress & modification factor,

f s = 0.58 x f y

1
MF
1
0.225 0.00322 x f s 0.625 x log 10
%pt

fs Steel stress of service load Mpa To be calculated


%pt Percentage of steel - Input
MF Modification factor - To be calculated

User has to define % pt on the basis of assumption (generally varies from 0.12 to
0.5%).

3.2 Effective depth & thickness of slab,

L
d permissible
Bv x MF

Bv = basic values as per IS code,

MF = modification factor.

t d d'

L Clear span of slab mm Input


BV Basic value - As per IS code
MF Modification factor - Calculated in 3.1
t Thickness of slab mm To be calculated
d Effective depth of slab mm To be calculated
d Effective cover of slab mm Input

7
FEAST Software Pvt. Ltd RCC One-Way Slab

3.3 Design moment (M), Design shear force (P)

If user has provided design moment then consider that value or else calculate as
follows,

Dead Load = 25 x thickness of slab

Live load & floor load as per input

w DL LL FL
w x L eff 2
M moment
8
w xL
V shear force
2

L eff = L + d

DL Dead load kN/m2 To be calculated


LL Live load kN/m2 Input
FL Floor load kN/m2 Input
W Design load kN/m2 To be calculated
M Design moment/Input kNm To be calculated
V Design shear force/Input kN To be calculated

3.4 Maximum depth of Neutral Axis (xu max), Q, d required

cbc
Mr b x x c x x z M
2
xc 280
z d m
3 3cbc
xdxm
x c cbc
st cbc x m

b=1000mm always, Es =200000 N/mm2

Compute the equation & get the value of drequired.

8
FEAST Software Pvt. Ltd RCC One-Way Slab

Check 1 If d required > d provided then revise the depth by addition of 5mm &
redesign.

m Modular ratio - To be calculated


cbc Permissible stresses in Concrete Mpa Input
st Permissible stresses in steel Mpa Input
xc Critical depth of Neutral Axis mm To be calculated
z Lever arm mm To be calculated
d Effective Depth required mm Input
xc Actual Depth of Neutral Axis mm To be calculated
b Slab width = 1000mm mm Input
Mr Moment of resistance kNm Input

3.5 Area of reinforcement

M
A st
st x z

Ast Area of tensile steel mm2 To be calculated


st Permissible stresses in steel Mpa Input
z Lever arm mm Calculated in 3.4
1000 x A1
Sv
A st

Sv Spacing of bars mm To be calculated


Ast Area of tensile steel mm2 Calculated above
A1 Area of bars ie 8, 10, 12 mm2 To be calculated

Distribution steel/minimum steel = 0.12 % x b x D

Check 2: Ast main < minimum area

If main area of reinforcement is less than minimum area required, then provide
minimum Ast as main Ast.

9
FEAST Software Pvt. Ltd RCC One-Way Slab

b Width of slab mm 1000mm always


D Overall thickness of slab - Calculated in 6.2

3.6 %pt, k, c, v,

100 x A stprovided
%pt
b x d provided

b = 1000mm always.

Find value of K in IS 456 as per thickness of slab (page no 84).

Find c, as per IS 456 (page no 84)

V
v
b x d provided

%pt Percentage of steel - To be calculated


Ast Area of steel provided mm2 Calculated in 3.5
b Width of slab mm 1000mm always
d Effective depth of slab provided mm Calculated in 3.2
tc Shear capacity of concrete Mpa To be calculated
tv Shear capacity of beam Mpa To be calculated
V Shear force kN Input

Check 3 If v K c , increase d provided & redesign.

3.8 Deflection check

%pt provided = 100 x Ast provided

b x d provided

A strequired
f s' 0.58 x x fy
A stprovided

10
FEAST Software Pvt. Ltd RCC One-Way Slab

1
MF'
1
0.225 0.00322 x f s' 0.625 x log 10
%pt provided

Actual deflection = L/d

Permissible deflection = Bv x MF

Check 4 If Actual deflection > permissible deflection then revise the depth by
addition of 5mm & redesign till satisfies the condition

pt Percentage of tensile steel mm2 To be calculated


Ast Area of main tensile steel mm2 Input
b Beam width mm Input
d Effective Depth mm Input
fs Steel stress of service load revised Mpa To be calculated
fy Diameter of vertical stirrups mm Input
%pt Percentage of steel - Input
MF Modification factor revised - To be calculated
L Clear span of slab mm Input

11
FEAST Software Pvt. Ltd RCC One-Way Slab

7. Flow chart Start

Input (3.1)

Calculate d provided & thickness (3.2)

Calculate d required (3.4)

No d provided
Revise the depth by addition of 5mm
> d required
& redesign till the condition satisfies

Yes

Calculate Area of Steel Ast (3.5)

No Ast >
Revise the depth by addition of 5mm
& redesign till the condition satisfies AMin
st < A
Ast st min

no
Yes

Calculate Vu, k, (3.6)

Revise the depth by addition of 5mm


No
& redesign till the condition satisfies

Yes
Calculate %pt provided, fs, MF (3.7)

12
FEAST Software Pvt. Ltd RCC One-Way Slab

Calculate (l/d)actual , (l/d)permissible(3.7)

Revise the depth by addition of 5mm (l/d)per >


& redesign till the condition satisfies (l/d)act

Stop

8. Parameter Constraints

Under-reinforce One-Way RCC Slab (Design)

Sr. Input Lower Upper Decimal Units

13
FEAST Software Pvt. Ltd RCC One-Way Slab

No. Limit Limit allowed

1. Steel Reinforcement 6 12 No mm
Diameter. Choose from a
drop-down menu
between 6, 8, 10, 12

2. Spacing of bars s 2 --- No --

s < smax

and s > smin

smin is lesser of

(a)

(b)

(c)

Smax is greater of

(a)

(b)

(c)

3. Overall Thickness t of 50 ---- Yes mm


slab choose from a drop-
down menu or specify
value for other.

50, 60, 70, 80, 90, 100,

14
FEAST Software Pvt. Ltd RCC One-Way Slab

110, 120, 125, 130, 140,


150, 160, 170, 180, 190,
200, or other.

4. Grade of concrete 20 200 No MPa


(numeral indicates fck).
Choose from drop-down
menu M20, M25, M30,
M35, M40, or other.

5. Grade of Steel (Numerals 250 550 No MPa


indicate fy). Choose from
drop-down menu Fe250,
Fe415, Fe500, Fe550

9. GUI Messages

1. Lx > Ld then, revise grade of concrete or grade of steel.

15
FEAST Software Pvt. Ltd RCC One-Way Slab

10. GUI Layout

16
FEAST Software Pvt. Ltd RCC One-Way Slab

17

Вам также может понравиться