Академический Документы
Профессиональный Документы
Культура Документы
Use this command to activate the configuration of a typical traffic Radio Access Bearer (RAB).
RAB is used to identify the service the Access Stratum (AS) provides for the Non-Access Stratum (NAS) to transfer user data bet
Use this command to add an IP MUX pipe to enable the multiplexing of IP packets. This command is applicable to the FG2a, GO
Use this command to add an IPPOOL MUX pipe to enable the multiplexing of IP packets. This command is applicable to the FG2
Multiple short packets are multiplexed into one UDP/IP header to reduce the IP overhead, thus improving the transmission effi
Threshold for the number of users in compressed mode for triggering the service-based UMTS-to-LTE measurement. UEs are a
this parameter is set to 0, the restriction is not effective.
Switch for controlling the connection-oriented cell-level algorithm. When this switch is selected, the corresponding algorithm is e
Use this command to add the Dynamic Channel Reconfiguration Control (DCCC) algorithm parameters of a cell.
Use this command to add cell-oriented handover common parameters.
1. Maximum number of RRC Connection Request message retransmissions.
2. Timer started after a UE sends an RRC Connection Request message to the BSC6900 and stopped after the UE receives an RR
N300. Otherwise, the UE enters the idle mode.
Use this command to add cell-oriented coverage-based inter-frequency handover measurement algorithm parameters.
Coverage-based handovers are triggered by event 2D or event 2F.
The reporting modes of coverage-based inter-frequency handovers are classified into event-triggered reporting mode and peri
Use this command to add cell-oriented coverage-based inter-RAT handover measurement algorithm parameters.
Coverage-based handovers are triggered by event 2D or event 2F. For coverage-based inter-RAT handovers, inter-RAT measurem
The
Use reporting modes
this command to of
addcoverage-based inter-RAT
threshold parameters handovers
related to cellconsist of event-triggered reporting mode and periodical reportin
load decision.
Use this command to add function control items in a cell.
Use this command to add the priority information of neighboring E-UTRA (for LTE networks) frequencies of the serving cell, inc
Use this command to add transmit power parameters of the DL link in a cell.
Use this command to add cell-oriented measurement algorithm parameters for non-coverage-based UMTS-LTE handovers.
Non-coverage-based handovers are triggered by any event except event 2D and event 2F. Only the event-triggered reporting m
Use this command to add a FACH. FACH: Forward Access Channel.
Use this command to add the transport format set (TFS) of a FACH.
Use this command to add a logical channel mapped to a FACH.
Use this command to add a type allocation code (TAC) and to configure functions for UEs identified by the TAC.
Use this command to add the mapping of differentiated QoS policy for PS BE services, thereby providing differentiated QoS.
Use this command to add a PCH(Paging Channel). Each SCCPCH can be configured with 0~1 PCH. The total number of PCHs and
Use this command to add the dynamic information of the transport format Set (TFS) of a PCH.
Use this command to add a PICH. The PICH is used to carry paging indicators (PIs). It is usually associated with the SCCPCH the
Use this command to add the basic parameters of physical layer of a SCCPCH before cell activation.
Use this command to add the Calculated Transport Format Combination (CTFC) of a SCCPCH.
Use this command to deactivate a cell, and make the cell data unavaliable.
Use this command to deactivate the high speed downlink packet access (HSDPA) function of a cell.
Use this command to deactivate the high speed uplink packet access (HSUPA) parameters of a cell.
Use this command to deactivate the SCCPCH configuration information to invalidate the related parameters.
Use this command to deactivate the configuration of a typical traffic RAB.
RAB is used to identify the service the Access Stratum (AS) provides for the Non-Access Stratum (NAS) to transfer user data bet
Use this command to export the MML script of configuration data on the OMU.
Use this command to modify the configuration information about an IP path. You can modify the configuration information suc
1. Use this command to modify the power offset information of the AICH in a cell.
2. An AICH is used to carry acquisition indicators, each of which corresponds to the signature of the RACH.
Modify the basic information of a cell, including Max transmit power of cell, Num of continuous in sync ind, Num of continuo
Use this command to modify algorithm switches of a cell.
Use this command to modify cell-oriented Call Admission Control (CAC) algorithm parameters.
Use this command to modify the information about an intra-frequency neighboring cell.
Use this command to modify the random access control parameters of an RACH.
Use this command to modify the configurations of a SCCPCH.
Use this command to modify the basic information of the typical Radio Access Bearer (RAB).
RAB is used to identify the service the Access Stratum (AS) provides for the Non-Access Stratum (NAS) to transfer user data bet
Use this command to modify HSUPA Power Control parameters for a typical Radio Access Bearer (RAB).
Use this command to modify Radio Link Control (RLC) parameters for a subflow of a typical Radio Access Bearer (RAB), such as
Modify semi-static Transport Format (TF) parameters for a typical traffic Radio Access Bearer (RAB).
Use this command to remove cell-oriented coverage-based inter-frequency handover measurement algorithm parameters.
Use this command to remove function control items in a cell.
Use this command to remove a FACH(Forward Access Channel).
Use this command to remove the transport format Set (TFS) of a FACH.
Use this command to remove the logical channel mapped to a FACH in a cell.
Use this command to remove a PCH.
Use this command to remove the dynamic information of Transport Format Set (TFS) of a PCH.
Use this command to remove a PICH.
Use this command to remove a SCCPCH.
Use this command to set parameters related to measurement report collecting areas. You can use this command to enalbe the
Use this command to set the cell-oriented algorithm parameters of an BSC6900.
Use this command to set RNC-Oriented Outer Loop Power Control (OLPC) algorithm parameters.
Use this command to set channel type and bit rate for RRC (Radio Resource Control) connection establishment according to the
Use this command to set process switches.
Use this command to set the weight associated with the scheduling priority. This weight is used in two algorithms:
In scheduling algorithm, it is used to adjust the handling priority for different services;
In Iub congestion algorithm, it is used to allocate bandwidth for different services. If the weight is higher, it is more possible for
Use this command to set the RNC-oriented SRNS Relocation (SRNSR) algorithm parameters.
Use this command to set BSC6900-oriented measurement algorithm parameters for non-coverage-based UMTS-LTE handovers
None-coverage-based inter-RAT handovers are triggered by factors other than the event 2D, event 2F. Only the event-triggered
Use this command to set UE State Transition Algorithm Parameters.
UE state transition means that in connected mode, the state of the UE transits from one state to another. The states include CE
Use this command to set UE State Transition Timer Algorithm Parameters.
UE state transition means that in connected mode, the state of the UE transits from one state to another. The states include CE
Use this command to set the user-plane algorithm switches.
Use this command to start a VSWR test for a BTS. Through remote precision test and VSWR query, you can determine whether
Neighboring
Neighboring
Neighboring
Neighboring
Neighboring
Neighboring
Neighboring
Neighboring
Neighboring
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Parameter Tuning and PES
Retune frequency
Retune frequency
Parameter Tuning
Parameter Tuning
Parameter Tuning
Use this command to configure parameters related to the Small Packet Resource Balancing feature.
Use this command to set other parameters related to the general packet radio service (GPRS) of a cell.
Use this command to set standard network optimization parameters related to a cell.
Use this command to set TRX Channel
MML Command
SET GTRXDEV
SET GTRXCHAN
SET GCELLHOINTERRATLDB
SET GCELLSOFT
SET GCELLHOPTP
SET GCELLHOEMG
SET GCELLIDLEAD
SET GCELLIDLEBASIC
SET GCELLHOFAST
SET GCELLHOEDBPARA
SET GCELLBASICPARA
SET GCELLCCAD
SET GCELLCCTMR
SET GCELLCCBASIC
UTRAN SET GCELLCCUTRANSYS
AMR SET GCELLCCAMR
SET GCELLCCACCESS
SET GCELLHOIUO
SET GCELLPWRBASIC
SET GCELLHOAD
SET GCELLHOFITPEN
SET GCELLHOCTRL
SET GCELLHOBASIC
SET GCELLOTHBASIC
SET GCELLCCCH
SET GCELLCHMGAD
SET GCELLCHMGBASIC
UTRAN FDD SET GCELLHOUTRANFDD
III SET GCELLPWR3
FDD BA2 SET GCELLHOFDDBA2
AMR SET GCELLAMRQUL
PS SET GCELLPSOTHERPARA
2G SET GCELLPRIVATEOPTPARA
2GPS SET GCELLPSBASE
2GGPRS SET GCELLGPRS
2GGPRS SET GCELLPSCHM
2GEGPRS SET GCELLEGPRSPARA
2GAbis SET GCELLPSABISPARA
RMV GCELLFREQ
3G ADD G3GNCELL
3G ADD GEXT3GCELL
2G ADD G2GNCELL
2G ADD GEXT2GCELL
COL LOG
EXP CFGBCP
EXP CFGMML
EXP LOG
BKP DB
ADD GCELLFREQ
BSCGSM MOD GCELL
STR BTSVSWRTST
3G RMV G3GNCELL
3G RMV GEXT3GCELL
2G RMV G2GNCELL
2G RMV GEXT2GCELL
MOD GTRX
MOD GCELLMAGRP
3G MOD G3GNCELL
3G MOD GEXT3GCELL
2G MOD G2GNCELL
2G MOD GEXT2GCELL
MOD GCELL
RMV G2GNCELL
RMV G3GNCELL
SET GCELLADMSTAT
ADD GCELL
ADD GCELLMAGRP
ADD GCELLQUICKSETUP
MOD UEXT2GCELL
RMV GCELL
RMV GCELLMAGRP
SET BSCPSSOFTPARA
SET BTSRXUBP
SET G3GARFCN
SET GCELL2GBA1
SET GCELL3GARFCN
SET GCELLADMSTAT
SET GCELLBTSSOFTPARA
SET GCELLHO2GBA2
SET GCELLHOPQUICKSETUP
SET GCELLHOPQUICKSETUP
SET GCELLMAIOPLAN
SET GCELLNC2PARA
SET GCELLNCRESELECTPARA
SET GCELLOTHEXT
SET GCELLPRACH
SET GCELLPSCS
SET GCELLPSPWPARA
SET GCELLPWR2
SET GCELLRESELECTPARA
SET GCELLSERVPARA
SET GCELLSTANDARDOPTPARA
SET GCELLTMR
SET GCSCHRCTRL
SET GCSCHRSCOPE
SET GTRXCHANHOP
SET GTRXHOP